Why Teams call analytics are critical to your entire business
Manual IKA232-20-230V
1. Efficient installations
2-poles installation contactor
Thermal current: 32 A
Rated current AC-1: 32 A
AC remote control
Installation contactor for applications such us residential, hospitals, hotels and business premises
Fast switching of motors, electric heating, lights and lighting, all kind of electrical and electronic equipment
Mounting on 35 mm rail
Degree of protection IP20
Installation Contactor
IKA232-20/230 V
Series 200
Advanced operation
Other benefits
2. Installation Contactor
IKA232-20/230 V
Technical data IKA232-20/230 V
General
Main circuit
Standard
Rated insulation voltage
1
4
6
3 x 10
32
-15 ... +55
230
-40 ... +80
50/60
max.3
32
NO: 9 ; NC: 6
32 / 24 V / 1 pole
max.240 - 50 °C
17 V; > 50 mA
3.6
7.0
NO: 1.3 ; NC: 0.75
1 ... 10
100.000
NO: 150.00 ; NC: 100.000
300.000
1 ... 6
M3.5
PZ1
1.2
2.5
72
32
300
600
3000
0.13
IEC/EN 60947-4-1, IEC/EN 61095
440
Module width (1 module width = 17.5 mm)
Rated impulse withstand voltage
Mechanical endurance
Thermal current
Ambient temperature
Rated operational voltage
Storage temperature
Rated frequency
No. of contactors side-by-side
Rated operational current
Rated operational current
Rated operational current
< 40 °C
AC-1-Non-inductiveorslightlyinductiveloads,resistancefurnaces
AC-3-Squrrel-cagemotors,starting:switchingoffduringrunning
DC-1-Non-inductiveorslightlyinductiveloads,resistivefurnaces
AC-7a-Slightlyinductiveloadsinhouseholdappliancesandsimilarapplications
AC-7b-Motor-loadsforhouseholdapplications
Contact reliability
Operational power for AC-1/AC-7a
Operational power for AC-3/AC-7b
Electrical endurance for DC-1
Electric endurance for AC-1/AC-7a
Electric endurance for AC-3/AC-7b
Terminal capacity
Screw
Screw head
Tigtening torque
Min. distance of open contacts
Power dissipation per pole
Overcurrent withstand capability
Max. back-up fuse for short-circuit protection gG (gL) - coordination type 1
Max. operating frequency
AC-1/AC-7a/AC-3/AC-7b/lamploads
single-phase 230V
single-phase 230V
rigid
flexible
L/R<1ms
Noload
DC-1
Weight
°C
V
°C
Hz
mm
W
kW
W
op.c.
op.c.
op.c.
A
A
V
kV
A
A
A
A
kg
Iv
Ui
Ith
Ie
Ie
Ie
S 2
mm
Nm
Pe
Pe
Ue
f
Uimp
Efficient installations
3. Dimensions
Contact arrangements
Operation position
• Published by Iskra, d. d. • Version 1.0 October 2015
www.iskra.eu
Installation Contactor
IKA232-20/230 V
Technical data IKA232-20/230 V
Control circuit
Range of control voltage
AC
230
50/60
2
15 - 25
1 ... 2.5
2.8 / 1.2
10 - 30
1 ... 2.5
2
0,6
85 ... 110
Kind of voltage
Control voltage
Frequency (AC)
Surge immunity test (1.2/ 50 µs) acc. to IEC/EN 6100-4-5
Coil consumption
Delays
Terminal capacity
Surge immunity test (1.2/ 50 µs) acc. to IEC/EN 6100-4-5
Tighening torque
Hz
Uc
Uc
f
S
%
V
kV
VA/W
ms
2
mm
kV
Nm
make
rigid
operation
break
flexible
A2 2 4
A1 1 3
IKA232-20/ 230 V
15° 15°180° 15° 15°
45
85
17.5
35
5
60
44
Ordering data
IKDA32 – 20 / 230 V
Control voltage
Version of contacts
Type