ESTAP HEAD OFFICE - SANCAKTEPE / İSTANBUL

ESTAP FACTORY - ESKİŞEHİR

40.000 m2 open area, 20.000 m2 closed area. Making p...
CONTENTS
FREE STANDING CABINETS
ServerMAX 	

600x1000 - 800x1000	

3-22

DCMax Datacenter solutions		

23-26

Universal Li...
ServerMAX free standing

•	 Compatible with all EIA-310 		
	 compliant 19” equipment.  All 	
	 type of servers, brands wil...
ServerMAX free standing
600x1000 - 800x1000

ServerMAX free standing enclosure

26U	 36U	

42U	

47U

		

42U	

47U

	

60...
SERVERMAX FREE STANDING ENCLOSURES FOR	

STANDARD DIMENSIONS:
Heights: 26U, 36U, 42U, 47U
Width: 600 mm
Depth: 1000 mm
Hei...
ServerMAX free standing
600x1000 - 800x1000

Optional plexi front door: May be used instead of
vented front door.  
All in...
FEATURES	

Quick release side doors: During installation and while
conducting routine maintenance of installed equipment, ...
ServerMAX free standing
FEATURES 	

600x1000 - 800x1000

Grounding: All parts are fitted with grounding studs to
provide e...
ADDITIONAL FEATURES FOR 	

More Volume Width=780 mm:
Provides more efficient
cooling and more
professional cabling
ServerM...
ServerMAX free standing
SELECTION STEPS FOR	

600x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to E...
PART NUMBER DEFINITION FOR 	

600x1000

FX***

MAIN PART NUMBER STRUCTURE
	

SRV 	
Product
range
ServerMAX

F14**

U
heigh...
ServerMAX free standing
TECHNICAL DRAWINGS FOR 	

600x1000 - 26U/36U/42U/47U

R07* / ***

F14** / ***
F15***

Exploded vie...
TECHNICAL DRAWINGS FOR	

600x1000 - 26U/36U/42U/47U

565
200

180

(Min 795)
740

H

Front view

Bottom view

Mounting pro...
ServerMAX free standing
PART NUMBER DEFINITION FOR	

800x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In additi...
PART NUMBER DEFINITION FOR	

800x1000

FX***

MAIN PART NUMBER STRUCTURE

Front door options

	 SRV 	 - 	HHU 	- 	 WW
Produ...
ServerMAX free standing
TECHNICAL DRAWINGS FOR	

800x1000 - 42U/47U

R08*/***

F16**/***
F17***

Exploded view

Part
numbe...
TECHNICAL DRAWINGS FOR	

800x1000 - 42U/47U

780

745

F16**

(Min 762)
740

H

(Min 27)
44

140

140

906

200

(Min 190)...
ServerMAX free standing
TECHNICAL DRAWINGS FOR	

600x1000

Technical drawing of extention unit D=200 mm for 600x1000 mm Se...
TECHNICAL DRAWINGS FOR 	

800x1000

Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX
Top view after ...
ServerMAX free standing
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment	 	
	
EN61587-1/4.2, IEC60068-2-1, I...
TECHNICAL SPECIFICATIONS

Custom number
85380000 / 85381000 / 853710990019
Packs of (ea.)
1
Shipping structure
Assembled
M...
ServerMAX free standing accessories
FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAX

Estap has a wide range of a...
Data Center solutions

’Data center solutions
which is mission critical,
require reliable, flexible
and scalable infrastru...
Data Center

solutions

MAIN FEATURES
DCMax data center server cabinets are designed to provide
hot corridor, cold corrido...
Data Center solutions

LCD CONSOLES & KVM
The high quality KVM switch is ideal for use in small to middle sized server
roo...
Data Center

solutions

Data Center solutions

ESTAP
Data center
COOLING
SOLUTIONS
Estap data center IT cooling
solution e...
Universal Line free standing

•	 Provides unique features for 	 	
	 system designers, installers and 	
	 network managers....
Universal Line free standing enclosures
600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000

Universal Line free s...
UNIVERSAL LINE ENCLOSURES FOR	

STANDARD DIMENSIONS:
Heights:16U, 20U, 22U, 26U 32U, 36U, 39U,
42U, 44U, 47U
Width: 600 mm...
Universal Line free standing enclosures

Universal Line free standing enclosures
offer a wide range of options.

30
UNIVERSAL LINE FREE STANDING ENCLOSURES FOR 	

600x600 - 600x800 - 600x1000

EASY TO ACCESS
Front door
Features a full-len...
Universal Line free standing
SELECTION STEPS FOR	

600x600 - 600x800

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In...
PART NUMBER DEFINITION FOR	

600x600 - 600x800

FX

MAIN PART NUMBER STRUCTURE
	

CKR 	
Product
range
Universal Line

F01*...
Universal Line free standing
TECHNICAL DRAWINGS FOR	

600x600 - 16U/20U/22U

R01**

F01*

F02

F03

F04

Exploded view

Pa...
TECHNICAL DRAWINGS FOR 	

600x600 - 16U/20U/22U

600

395

F01*
(Min 30)
111

300

(Min 520)
390

478

200

H

(Min 45)
95...
Universal Line free standing
TECHNICAL DRAWINGS FOR	

600x800 - 16U/20U/22U

R01**

F01*

F02

F03

F04

Exploded view

Pa...
TECHNICAL DRAWINGS FOR	

600x800 - 16U/20U/22U

600

F01*

395

200

(Min 30)
130

300

658

(Min 701)
555

H

(Min 45)
91...
Universal Line free standing
TECHNICAL DRAWINGS FOR 	

600x600 - 26U/32U/36U/39U/42U/44U/47U

R02**

F01*

F02
F03
F04

Ex...
TECHNICAL DRAWINGS FOR 	

600x600 - 26U/32U/36U/39U/42U/44U/47U

600

F01*

395

H

(Min 520)
390
(Min 45)
95

478

200

(...
Universal Line free standing
TECHNICAL DRAWINGS FOR	

600x800 - 26U/32U/36U/39U/42U/44U/47U

R02**

F01*

F02
F03
F04

Exp...
TECHNICAL DRAWINGS FOR 	

600x800 - 26U/32U/36U/39U/42U/44U/47U

395

600

F01*

200

(Min 30)
130

300

(Min 45)
91

658
...
Universal Line free standing
SELECTION STEPS FOR 	

600x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In additio...
PART NUMBER DEFINITION FOR 	

600x1000

FX

MAIN PART NUMBER STRUCTURE
	

CKR 	
Product
range
Universal Line

CKR

Front d...
Universal Line free standing
TECHNICAL DRAWINGS FOR 	

600x1000 - 26U/36U/42U/47U

R01
R03
F04
R02**

F05*

F06
F07
F08

E...
TECHNICAL DRAWINGS FOR 	

600x1000 - 26U/36U/42U/47U

600

395

F05*

200

(Min 30)
150

300

878

(Min 921)
740

H

Front...
Universal Line free standing
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment	 	
	
EN61587-1 / 4.2, IEC60068...
TECHNICAL SPECIFICATIONS

Custom number
85380000 / 85381000 / 853710990019
Shipping structure
Assembled
Mounting type
Stan...
Universal Line JUMBO

free standing

SELECTION STEPS FOR 	

800x800

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In ...
PART NUMBER DEFINITION FOR 	

800x600 - 800x800

FX

MAIN PART NUMBER STRUCTURE
	
CKR 	
- 	HHU 	- 	WD
Product
range
Univer...
Universal Line JUMBO
TECHNICAL DRAWINGS FOR	

800x600 - 32U/36U/39U/42U/44U/47U

F12***
R05
R04**
R06*

F09*
F10
F11
R04**...
TECHNICAL DRAWINGS FOR 	

800x600 - 32U/36U/39U/42U/44U/47U

F09*

515

F10

780

300
478

(Min 408)
365

55

H

(Min 138)...
Universal Line JUMBO
TECHNICAL DRAWINGS	

800x800 - 32U/36U/39U/42U/44U/47U

F12***
R05
R04**
R06*

F09*
F10
F11
R04**
F12...
TECHNICAL DRAWINGS FOR 	

800x800 - 42U/47U

515
300
(Min 40)
95

F10
780

(Min 720)
550

780

H

H

(Min 130)
131

658

3...
Universal Line JUMBO free standing
SELECTION STEPS FOR 	

800x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In a...
PART NUMBER DEFINITION FOR 	

800x1000

FX

MAIN PART NUMBER STRUCTURE
	

CKR 	

- 	HHU 	- 	WD

Product
range
Universal Li...
Universal Line JUMBO
TECHNICAL DRAWINGS FOR	

800x1000 - 42U/47U

F12***
R05
R04**
R06*

F09*
F10
F11
R04**
F12***

Explod...
TECHNICAL DRAWINGS FOR 	

800x1000 - 42U/47U

515
300
(Min 26)
120

F10

780

780

(Min 852)
740
(Min 118)
136

878

300

...
Universal Line JUMBO
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment	 	
	
EN61587-1 / 4.2, IEC60068-2, IEC6...
TECHNICAL SPECIFICATIONS

Custom number
85380000 / 85381000 / 853710990019
Shipping structure
Assembled
Mounting type
Stan...
Universal Line JUMBO

Accessories

SPECIAL ACCESSORIES* FOR JUMBO

Teleskopic cable trunking
Designed to protect and hide ...
UNIVERSAL LINE JUMBO FEATURES

Perforated, vented  
Pagoda-style top
providing maximum
protection against dust

Front door...
Universal Line PCcase free standing
	

600x800 - 36U

STANDARD DIMENSIONS:
Height: 36U
Width: 600 mm
Depth:  780 mm

STAND...
600x800 - 36U

FEATURES
PCccase cabinets match all features defined for
Universal Line as main construction.
It has 3 sect...
Universal Line PCcase
TECHNICAL DRAWINGS	

600x800 - 36U

Exploded view

Height:
without
levelling feet
(mm)

Height:
with...
TECHNICAL DRAWINGS FOR 	

600x800 - 36U

395

600

(Min 30)
91

1746

(Min 701)
555

658

200

(Min 30)
130

300

19”

Bot...
Universal Line

free standing accessories

FREQUENTLY USED ACCESSORIES SELECTION TABLE FOR Universal Line

Estap has a wid...
EUROline free standing

Reduce

%ip5e0t
sh m n

*

cost

•	 Real flatpack design
•	 Max. 10 min** for assembly
•	 Easy to ...
EUROline free standing
600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000

EUROline free standing enclosures

22U...
600x600 - 600x800 - 600x1000 - 800x800 - 800x1000

STANDARD DIMENSIONS:
Heights: 22U, 26U, 32U, 36U, 42U
Width: 600 mm
Dep...
EUROline free standing
SELECTION STEPS FOR 	

600x600 - 600x800

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addi...
PART NUMBER DEFINITION 	

600x600 - 600x800

FX

MAIN PART NUMBER STRUCTURE
	

EU 	

Front door option

- 	 HU 	- 	WD
H

P...
EUROline free standing
TECHNICAL DRAWINGS FOR 	

600x600 - 22U/26U/32U/36U/42U

R10

F18

*

Exploded view

Part
number

P...
TECHNICAL DRAWINGS FOR 	

600x600 - 22U/26U/32U/36U/42U

F18

600

H

(Min 93,5)
155

566

(Min 455)
331,5

(Min 91,5)
153...
EUROline free standing
TECHNICAL DRAWINGS FOR 	

600x800 - 22U/26U/32U/36U/42U

R10

F18

*
Exploded view

Part
number

Pr...
TECHNICAL DRAWINGS FOR 	

600x800 - 22U/26U/32U/36U/42U

521

F18

(Min 635)
511,5

746

(Min 91,5)
153

600

(Min 91,5)
1...
EUROline free standing
SELECTION STEPS FOR 	

600x1000

STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE
In addition to E...
PART NUMBER DEFINITION FOR 	

600x1000

FX

MAIN PART NUMBER STRUCTURE
	

Front door options

EU 	 - 	HHU 	- 	WD
Product
r...
EUROline free standing
TECHNICAL DRAWINGS FOR 	

600x1000 - 42U

R07

R10**

F21
F18*

Exploded view

Part
number

Product...
TECHNICAL DRAWINGS FOR 	

600x1000 - 42U

600

522

(Min 85,5)
147

522

(Min 825,5)
702,50

926

463

(Min 86,5)
148

F18...
EUROline free standing
SELECTION STEPS FOR 	

800x800 - 800x1000

STEPS TO SELECT RIGHT FREE STANDING ENCLOSURE
In additio...
PART NUMBER DEFINITION 	

800x800 - 800x1000

FX

MAIN PART NUMBER STRUCTURE
	
EU	 - 	HHU	 - 	WD
Product
range
EUROline

E...
EUROline free standing
TECHNICAL DRAWINGS FOR 	

800x800 - 32U/36U/42U

F19**
R08**
R11
R12****

F19**
F20***
R08**

*

Ex...
TECHNICAL DRAWINGS FOR 	

800x800 - 32U/36U/42U

780

F20*

701

(Min 725)
511,5

H

(Min 47,5)
154

776

746

(Min 44,5)
...
EUROline free standing
TECHNICAL DRAWINGS FOR 	

800x1000 - 42U

F19**
R08**
R12****
R11

F19**

F20***
R08**

*

Exploded...
TECHNICAL DRAWINGS FOR 	

800x1000 - 42U

701
513

780

H

(Min 40)
146,5

926

(Min 784,5)
704,50

(Min 40)
146,5

F20*

...
EUROline free standing
TECHNICAL SPECIFICATIONS

TESTS AND CERTIFICATIONS
Environment			
EN61587-1/4.2, IEC60068-2-1, IEC6...
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Estap 2012-2013 catalogue all pages
Upcoming SlideShare
Loading in...5
×

Estap 2012-2013 catalogue all pages

2,086
-1

Published on

rack cabinet, rack cabin, rack cabinets, rack enclosure, rack enclosures, rock cabin,data cabinet, server cabinet, network cabinet, network cabin, 19''rack cabinet, cabinet, server cabin , rack cabinet price, rack cabin price, 42U cabinet, 19'', 16U, 20U, 22U,26U, 32U,39U,44U,47U,estap elektrik, estap eskişehir,estap eskişehir factory, enclosure, rack enclosure

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
2,086
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
34
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Estap 2012-2013 catalogue all pages

  1. 1. ESTAP HEAD OFFICE - SANCAKTEPE / İSTANBUL ESTAP FACTORY - ESKİŞEHİR 40.000 m2 open area, 20.000 m2 closed area. Making production with 400 employess.
  2. 2. CONTENTS FREE STANDING CABINETS ServerMAX 600x1000 - 800x1000 3-22 DCMax Datacenter solutions 23-26 Universal Line 600x600 - 600x800 - 600x1000 Universal Line JUMBO 800x600 - 800x800 - 800x1000 Universal Line PCcase 600x800 27-66 EUROline 8 00x800 - 800x1000 600x600 - 600x800 - 600x1000 67-88 ECOline 8 00x800 - 800x1000 600x600 - 600x800 - 600x1000 89-108 RELAYrack Single frame, D=600 Double frame, D= 800, D=1000 109-116 PROline 600x450 - 600x560 - 600x(160+450) 117-130 PROline Residential 600x150 - 600x300 131-136 EUROline wall mounting 600x450 - 600x600 137-146 ECOline wall mounting 600x450 - 600x600 147-156 WALL MOUNTING CABINETS SOHOline wall mounting 520x300 - 520x400 292x300 (10”) SOHO Slimline 157-166 167-168 OTHER PRODUCTS Fiber Optic Boxes 169-171 PDU 173-174 Accessories Free standing accessories Wall mounting accessories 175-215 OUTDOOR ENCLOSURES 217-224 QUALITY CERTIFICATIONS 225 IP PROTECTION CLASS 226 NOTES 227-228
  3. 3. ServerMAX free standing • Compatible with all EIA-310 compliant 19” equipment. All type of servers, brands will physically fit in ServerMAX server cabinet. • Bottom plate has an extra perforated plate to prevent insects or mice from reaching the cables. • Efficient passive air circulation • Numbered U positions facilitate easy installation of rack mounted equipment. 3
  4. 4. ServerMAX free standing 600x1000 - 800x1000 ServerMAX free standing enclosure 26U 36U 42U 47U 42U 47U 600 x 1000* 800 x 1000* ServerMAX protects your technological investments • 19” • HIGH QUALITY PRODUCTS • COMPLIMENTS YOUR DECOR AND ENVIRONMENT • SECURE AND STURDY • EASY TO MAINTAIN: LARGE INNER VOLUME • HIGH SECURITY FOR UNAUTHORIZED ACCESS • STRONG PROTECTION AGAINST PHYSICAL DAMAGE • EXCELLENT PASSIVE AIR VENTILATION * Please check drawing pages for cabinet sizes. 4
  5. 5. SERVERMAX FREE STANDING ENCLOSURES FOR STANDARD DIMENSIONS: Heights: 26U, 36U, 42U, 47U Width: 600 mm Depth: 1000 mm Heights: 42U, 47U Width: 780 mm Depth: 1000 mm LOAD CARRYING CAPACITY: 1000 kg 600x1000 -800x1000 COLOUR: RAL 9005 black RAL 7035 light grey STANDARDS: ISO 9001 : 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2 KEY FEATURES Adjustable mounting depth: 19” mounting angles are adjustable in depth for various mounts for adjustable depth distance, please look at drawing pages. Bottom plate: fitted with an additional plate to prevent insects/vermin. If necessary a filter may be integrated to prevent dust infiltration. Bottom plate is complete with pre-punched removable sections: when airflow comes from the floor, these sections can be removed to provide efficient airflow inside the cabinet. Reversible doors: Front and rear doors may be detached and reversed to allow the door to open from the rear of the cabinet. Side doors are split in two: Front section used to access the cabinet; additional smaller section secured inside the cabinet. If additional ventilation is necessary it can be demanded as vented. The main inner strip of this panel is designed for the housing of cables and power strips. Numbered “U” positions facilitate easy installation for rack mounted equipment. Vertical mounting rails with square holes; adjustable in depth. 5
  6. 6. ServerMAX free standing 600x1000 - 800x1000 Optional plexi front door: May be used instead of vented front door. All in one: ServerMAX includes; casters, doors, ground studs, levelling feet, roof, bottom, side panels, C-rails, tilt bars, unloaded fan tray. Optimized depth: 1000 mm.Today and next generation installation of servers, for power distribution and cable management. 1000 mm is the optimum depth for comfort cabling, housing server and gaining space in data centers. Fixing to floor: ServerMAX can be easily fixed to the floor when necessary. A floor fixing kit is used for this purpose. Please see accessories for floor fixing kit. Efficient passive ventilation: New generation servers and networking products need adequate ventilation to operate efficiently. ServerMAX server cabinets provide 6 efficient passive ventilation because of its vented structure of front and rear doors. Front and rear doors have maximum perforation (%63) patterns for high-density cooling that meets or exceeds server manufacturer’s ventilation requirements. There is a fan tray on roof: Removable easily from the top.When the maintanence of fans are required, it can be reached directly from the top without touching any mounted device or servers. It is possible to attach a filter on top of the server fan unit. Generous cable access holes are provided in the roof and base. One on top, one on bottom holes are special ESTAP style cable entries; sliding type with rubber edges.
  7. 7. FEATURES Quick release side doors: During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the side panels. Quick release slam latches and locks on the side panels allow for quick and easy access. 600x1000 - 800x1000 Anti-tilt bars: As standard, ServerMAX is fitted with 2 sliding type tilt bars to make the cabinet stable in weight center. Whenever the servers are moved out, tilt bars are drawn out to counter-balance the cabinets weight center. Double opening rear doors improve access and serviceability to rear of rack mounted equipment.The split rear doors help to maximize floor space. Only 390 mm for W=780 mm cabinets of clearance is required behind the enclosure to allow for door swing. D= 200 mm extention unit: If deeper equipment is loaded into ServerMAX cabinets requiring additional depth for cable radius, cable bundles, PDU housing etc, a D=200mm extension unit may be installed to ServerMAX cabinets: the rear door is removed and reinstalled onto the extension unit. (Please see diagrams on pages 18-19) Expansion: ServerMAX enclosures can be easily expanded to create complete rows of enclosures without side panels. With a proper baying kit (please see accessories) all cabinets are bayed easily and quickly. Welded: Bottom and roof of the cabinet is completely welded and a closed structure. Sturdy and rugged, it protects against physical elements like dust, insects. Lockable doors and side panels: Front and rear doors are lockable using a 3 point locking mechanism. A handle-style locking system provides increased security to prevent unauthorized access. All doors and side panels are only accessible with a key provided by ServerMAX. Stability: Heavy duty frame design, 2 mm mounting rails, angles, heavy duty type castor group provide 1000 kg load rating. 7
  8. 8. ServerMAX free standing FEATURES 600x1000 - 800x1000 Grounding: All parts are fitted with grounding studs to provide electrical continuity. Surface treatment: Fosfat coating, oil remove and passivation. Heavy duty vertical frames: Instead of 4ea. vertical profiles, ServerMAX cabinets are 6ea.(3ea.in left+3ea.in right) main vertical profiles that gives extra stability for heavy loads. Material thicknesses: Roof, bottom, vertical main frames, 1,5 mm C-rails, 19” mounting angles, profiles and all frames are 2 mm thickness. Sturdy steel construction. More C rails: Instead of 6ea. there are 8 horizontal C rails in depth for extra stability. (42U, 47U) Paint: Electrostatic powder coating. Reinforced bottom: Bottoms are reinforced with horizontal profiles in width and depth for extra stability. Rounded aesthetic monoblok front door: Front door is a heavy duty type monoblock perforated and welded structure. It’s shape is rounded in front to enhance the aesthetics. Easy to dismantle and assembly: The rigidly welded frame construction can be dismantled and assembled easily without any special tools.Thus, narrow doors, staircases and lifts are no problem. Special cable entry on top and bottom case: Bottom plate and top case have a special cable entry, completely closed, sliding type with rubber edges. Cables are entered and fixed. Housing for cabling: The cabinet itself has enough housing for vertical cable management at back. For 600x1000 cabinet, cable rings are used for cable management. For 780x1000 cabinets there are special vertical cable management panels of Ieft & right with cover plate for hiding and protecting the cables. These allow customers to easily route, manage and access large numbers of data cables even while an enclosure is loaded with rack mount equipment and bayed in a row. Power/energy distribution: Rear power distribution housing at back of the cabinet provide easy access to multiple receptacles. Vertical power distribution strips can easily be mounted in that space. This housing never interfere with equipment or takes any valuable “U” space. Providing increased accessibility to receptacles allows customers to support more power cords within the enclosure. Power strips are the length of cabinets: 26U, 36U, 42U, 47U. 8
  9. 9. ADDITIONAL FEATURES FOR More Volume Width=780 mm: Provides more efficient cooling and more professional cabling ServerMAX Width=780 mm cabinet has all features mentioned before. Plus these additional features. 800x1000 mm Vertical cable management panels can be used at rear of the cabinet for professional cabling and to hide the power cables. Extra Housing space for cabling and power distribution: This extra space provides housing for the vertical cable management panels and the vertical power strips. Left and right front panel: Front panels can be used to hide unwanted views of cables. If server cabinet is additionally used for networking in the front, cable management is needed: Estap cable rings can be used to attach this panel and secure cables.Access holes allow the patch cord to reach the rear of cabinet. 9
  10. 10. ServerMAX free standing SELECTION STEPS FOR 600x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure for ServerMAX W=600 mm: Product range name + U height (HHU) The product options have the below structure: Colour option (MX) + Front door option (FX) + Rear door option (RX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example : SRV42U (Width=600 mm) Step 2 Please choose the colour from the table and place it after the part number. For example : SRV42U - M01 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example : SRV42U - M01 - F15 (FX= look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example : SRV42U - M01 - F15 - R07 (RX= look at the RX rear door options on the next page) 10
  11. 11. PART NUMBER DEFINITION FOR 600x1000 FX*** MAIN PART NUMBER STRUCTURE SRV Product range ServerMAX F14** U height + SRV Front door options - HHU 600 HHU 26U 36U SRV 42U 47U H SRV : ServerMAX product range (W=600 mm) HHU : “U” height WD : 600x1000 mm Front view F15 R07* 600 OPTIONS MX - FX MX - RX Front door options Colour options + FX M01 F14** M02 600 Rear door options + RX R07* F15 H H R07* MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey Front view Front view RX*** Rear door option FX : Front door options F14**= Single opening, monoblock,welded, curved %63 perforated door, 3 point handled locking F15= Single opening, monoblock,welded, curved plexi glass door, 3 point handled locking R07* 600 RX : Rear door option q R07*= Double opening %63 perforated door with complete metal frame, 3 point handled locking H Back view H= Enclosure height * R07 is the standard rear door. ** F14 is the standard front door. *** F14, F15 R07 can be used as front or rear door. 11
  12. 12. ServerMAX free standing TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U R07* / *** F14** / *** F15*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with casters (mm) ServerMAX cabinets 19” 600 x 1000 mm SRV26U 26U 600x1000 mm 26 600 1000 740 1179 1291 1338 SRV36U 36U 600x1000 mm 36 600 1000 740 1623 1735 1782 SRV42U 42U 600x1000 mm 42 600 1000 740 1890 2002 2049 SRV47U 47U 600x1000 mm 47 600 1000 740 2112 2224 2271 * R07 is the standard rear door. ** F14 is the standard front door. *** F14, F15, R07 can be used as front or rear door. 12
  13. 13. TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U 565 200 180 (Min 795) 740 H Front view Bottom view Mounting profile 1000 12 600 F14** (Min 25) 56 140 140 906 200 (Min 158) 184 600 600 F15 H Front view 47 H Side view Back view Front view 600 200 R07* 1000 200 600 30 H Top view H= Enclosure height Iso view Front view *R07 is the standard rear door. ** F14 is the standard front door. 13
  14. 14. ServerMAX free standing PART NUMBER DEFINITION FOR 800x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure for ServerMAX W=780 mm: Product range name + U height (HHU) + Width (WW, D=1000 mm) The product options have the below structure: Colour option (MX) + Front door option (FX) + Rear door option (RX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example : SRV42U8 (Width=780 mm) Step 2 Please choose the colour from the table and place it after the part number. For example: SRV42U8 - M01 (MX= Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: SRV42U8 - M01 - F16 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: SRV42U8 - M01 - F16 - R08 (RX= Look at the RX rear door options on the next page) 14
  15. 15. PART NUMBER DEFINITION FOR 800x1000 FX*** MAIN PART NUMBER STRUCTURE Front door options SRV - HHU - WW Product range ServerMAX SRV Width & depth= 1000 mm U height + HHU + 780 8 42U SRV F16** WW 47U H SRV : ServerMAX product range HHU : “U” height WW : Width (W=780 mm) OPTIONS MX - FX - RX Front door options Colour options MX Front view + FX M01 F16** M02 F17 R08* 780 780 Rear door options + RX F17 R08* H H R08* MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey Front view Front view RX*** Rear door option FX : Front door options F16**= Single opening, monoblock, welded, curved %63 perforated door, 3 point handled locking F17= Single opening, welded, curved plexi glass door, 3 point handled locking R08* 780 RX : Rear door option R08*= Double opening %63 perforated door with complete metal frame, 3 point handled locking H Back view H= Enclosure height * R08 is the standard rear door. ** F16 is the standard front door. *** F16, F17 R08 can be used as front or rear door. 15
  16. 16. ServerMAX free standing TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U R08*/*** F16**/*** F17*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with casters (mm) ServerMAX free standing cabinets 19” 780 x 1000 mm SRV42U8 42U 780x1000 mm 42 780 1000 740 1890 2002 2049 SRV47U8 47U 780x1000 mm 47 780 1000 740 2112 2224 2271 * R08 is the standard rear door. ** F16 is the standard front door. *** F16, F17, R08 can be used as front or rear door. 16
  17. 17. TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U 780 745 F16** (Min 762) 740 H (Min 27) 44 140 140 906 200 (Min 190) 195 300 280 19” Mounting profile Bottom view 1000 780 12 780 Front view H H Side view 47 Front view F17 Back view Front view 780 780 R08* 200 300 Top view H= Enclosure height 29 1000 H Iso view Front view * R08 is the standard rear door. ** F16 is the standard front door. 17
  18. 18. ServerMAX free standing TECHNICAL DRAWINGS FOR 600x1000 Technical drawing of extention unit D=200 mm for 600x1000 mm ServerMAX Top view after extention unit 600 70 200 145 Note: Depth of existing cabinet + 200 mm Exploded view Iso view Part number Width: overall (mm) Depth: overall (mm) Height: without levelling feet (mm) Height: with casters (mm) SRV26U EXT620 26U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 26 600 200 1281 1328 SRV36U EXT620 36U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 36 600 200 1726 1773 SRV42U EXT620 42U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 42 600 200 1993 2040 SRV47U EXT620 18 Product definition (mm) U Size ServerMAX 19” 600 x 1000 mm extention unit 47U Extention unit D=200 mm, suitable for ServerMAX W=600 mm 47 600 200 2215 2262
  19. 19. TECHNICAL DRAWINGS FOR 800x1000 Technical drawing of extention unit D=200 mm for 780x1000 mm ServerMAX Top view after extention unit 780 70 200 145 Note: Depth of existing cabinet + 200 mm Exploded view Iso view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Height: without levelling feet (mm) Height: with casters (mm) ServerMAX 19” 780 x 1000 mm extention unit SRV42U EXT820 42U Extention unit D=200 mm, suitable for ServerMAX W=780 mm 42 780 200 1993 2040 SRV47U EXT820 47U Extention unit D=200 mm, suitable for ServerMAX W=780 mm 47 780 200 2215 2262 19
  20. 20. ServerMAX free standing TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class 2.3 Storage ETS300019-1-1 Class 1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 20 KEY FEATURES Main profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 90 degrees and consisting of 4 bends for each profile. In total; 16 folds provide framework stability.Additionally, 2 piece vertical side panel divider profile provides additional resistance each with a 4 fold design; total of 8 fold additional support. In total ServerMax main profile framework consists of a 24 fold engineering design. Manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Bottom and upper cases have a structure to increase the resistance and strength of the cabinet by monoblock bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper cases with screws. The bottom case providing cable access is fitted with a sliding blanking access plate to prevent dust. A rubber edge on the cable access plate and sliding structure, it is possible to fix the cables and allows cables to be placed into the cabinet without any damage. Additional there are pre-punched knock outs for air distribution delivered from raised floor. Rear door in standard configuration is a double opening door which is removable and lockable. Integral locking is a 3 point locking system. Rear doors can be opened up to 215 degrees, are removable and lockable with handle type locking unit. Side panels have a structure that can be opened and removed with slam latch and key.They are lockable and removable. Side panels consist of a divider profile which creates 2 pieces side panels on each side. Original functional side panel is lockable and removable as mentioned above; the smaller side panel is fixed from inner side with screws. If additional ventilation is needed this panel can be replaced with a slotted / perforated one. Within this engineering construction, the original functional side panel becomes easy to carry while the divider profile provides better resistancy. Front doors are single opening, monoblock, welded, curved, %63 perforated in standard. Integral locking as 3 point locking system. For options please see the related diagrams and technical charts in pages 11-15. Front door can be opened up to 215 degrees, removable and lockable with handle type locking unit. Vented top panel housing with a dedicated space for ventilation, the fan module system allows easy installation of max. 6 fans from top. 19”(inch) mounting angles (2ea. in front and 2ea. in rear) are part of cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels. Levelling feet and integrated castor group are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for enviroment with ISO 14001:2004 Environmental Management System.
  21. 21. TECHNICAL SPECIFICATIONS Custom number 85380000 / 85381000 / 853710990019 Packs of (ea.) 1 Shipping structure Assembled Mounting surface Stand alone Load carrying capacity (kg) 1000 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standart colour RAL 7035, RAL 9005 Baying Possible with baying kit for side by side applications without side panels IP protection standard IP20 FRONT DOOR Single opening, monoblock, welded,curved, %63 perforated Front door construction Monoblock curved, welded construction Front door lock Handle type, 3 point locking Hinge system Spring loaded Door opening angle and swapping 215 degree Door opening angle and swapping 215 degree FRAMEWORK Top and bottom base units Solid Metal 2 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 2 mm Uprights construction Tightly fixed into top and bottom base units 3 times folded 3 x 2 = 6 folds SIDE PANEL DIVIDER PROFILE Solid metal 2 mm Side panel construction Tightly fixed into top and bottom base units 4 times folded x 2 = 8 folds INTERIOR PARTS 19’’ mounting angles Solid metal, 2 mm 1 times folded for an L profile system U marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19’’ Zinc plated, passivated, 8-12 micron Adjustable in depth Omega type support rails in depth Solid metal, 1,5 mm 3 times folded for W=600 mm cabinets Omega type folded for W=780 mm cabinets 3 ea. at left, 3 ea. at right 26U and 36U 4 ea. at left, 4 ea. at right 42U and 47U SIDE PANEL Solid metal, 1 mm. Left and right (2ea.) Construction Lockable, removable c/with slam latches and lock Lock Barrel type lock unit, single point + slam latch (2ea) REAR DOOR Solid metal, 1 mm Rear door construction Double door opening, %63 perforated, lockable, removable Rear door lock Handled type lock unit, 3 point Hinge system Spring loaded For CUSTOMIZED PRODUCTS rather than above options, please contact sales department. 21
  22. 22. ServerMAX free standing accessories FREQUENTLY USED ACCESSORIES SELECTION CHART FOR SERVERMAX Estap has a wide range of accessories: Heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable managements, cable rings, organisers, trays, plinths and so on... * See the other and part number definition on pages 173-213. * Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light grey Frequently used accessories selection table ServerMAX / Vertical PDU part numbers M44 24 AL IEC AMP MCB ServerMAX / Cable management unit (suitable for 780x1000 Server Cabinets) Enclosure sizes* 800x1000 42U M44ORG42SRV 47U M44ORG47SRV ServerMAX / Cable management rings Part number 44x30 K44RING01 44x60 K44RING021U 44x110 K44RING03 70x160 K44RING04 ServerMAX / Floor fixing kit Enclosure sizes* 600x1000 800x1000 M44DPR03 22 * Please check drawing pages for cabinet sizes. M44DPR04
  23. 23. Data Center solutions ’Data center solutions which is mission critical, require reliable, flexible and scalable infrastructures alongside guarantied high performance. ESTAP OFFERS energy efficient MANAGABLE, MEASURABLE AND SCALABLE SOLUTIONS TO DATA CENTER PROJECTS. 23
  24. 24. Data Center solutions MAIN FEATURES DCMax data center server cabinets are designed to provide hot corridor, cold corridor and its containment structure, which has been widely used in enterprise datacenters. Design criteria serves to provide: • Maximum performance for cooling of IP20 and IP55 solutions • Wide range of cabinet sizes and accessories H=42/47U – W=600/800 mm – D=1000/1100/1200 mm • Load capacity= 1500 kg. DCMax structure is suitable for carrying heavy loads and is seismic tested to 1000 kg (BELLCORE GR-63-CORE ZONE 4, NEBS) • Maximum inner space for servers • Minimum environmental space requirement • Professional cable management • Heavy duty structure • Compability with all vendors servers • High technical performance, grounding continuity • Power / energy management • Controllable and reliable security with monitoring • Aesthetic and professional design 19” OPEN FRAME CABLING CABINET, IP20 Estap System Rack cabinet series offers an ideal solution for the data center which include high density cabling and need effective cooling. Its heavy-duty structure is suitable to house the component of the network backbone. 24 HOT & COLD CORRIDOR APPLICATIONS Estap datacenter cooling solution offers real and energy efficient cooling with its wide product range such as water chilled sidecoolers, in-row coolers, heat removal units, cold corridor containment and so on.
  25. 25. Data Center solutions LCD CONSOLES & KVM The high quality KVM switch is ideal for use in small to middle sized server rooms and provides direct connection to many servers. Estap consoles with/without integrated KVM are a space saving and functional solution for a comfortable connection to PCs, servers KVM installations in a 1U rack-mounting area. REMOTE MONITORING SYSTEM Supplies real time monitoring and management solution for data centers to secure flawless operation with high resilien. POWER DISTRIBUTION UNITS (PDU) Estap managed IP PDUs provide reliable power distribution and monitoring of individual outlets to data centers, for both Blade servers. Designed for high density, mission critical server applications, Estap IP PDU range offers an excellent solution to scale electrical power budgets and fight against the inevitable rise of electrical energy costs in the data center business. 25
  26. 26. Data Center solutions Data Center solutions ESTAP Data center COOLING SOLUTIONS Estap data center IT cooling solution ensures maximum IT availability at minimum running cost. The power usage effectiveness in the data centers indicates that approximately %30 of the total incoming power is utilised by cooling and cooling related equipment. FEATURES Cold corridor • Liquid / gas cooling • High cooling capacity • Easy mounting and maintenance ESTAP DATA CENTER COOLING SOLUTIONS Hot corridor 26 In Row coolers are utilised. To serve for cooling and/or enhancing the cooling capacity of a cold corridor containment. Heat rejection can be handled by an existing chilled water system: The modular solution serve scalable cooling capacity growth.
  27. 27. Universal Line free standing • Provides unique features for system designers, installers and network managers. • Suitable for office, equipment room and cabling closet installations • Exceptionally sturdy and strong • Highly cost-effective and assembly-friendly solutions for numerous applications • Multiple cable entry points provide maximum versatility • Delivered as assembled and side by side mounting is possible 27
  28. 28. Universal Line free standing enclosures 600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000 Universal Line free standing enclosures 16U 20U 22U 26U 32U 26U 36U 42U 36U 39U 42U 44U 47U 600 x 600* 600 x 800* 600 x 1000* 47U Universal Line JUMBO free standing enclosures 32U 42U 36U 39U 42U 44U 47U 800 x 1000* 47U Universal Line PCcase 36U 600 x 800* Highly cost-effective and assembly-friendly solutions for numerous applications * Please check drawing pages for cabinet sizes. 28 800 x 600* 800 x 800*
  29. 29. UNIVERSAL LINE ENCLOSURES FOR STANDARD DIMENSIONS: Heights:16U, 20U, 22U, 26U 32U, 36U, 39U, 42U, 44U, 47U Width: 600 mm Depth: 600 mm - 780 mm Heights: 26U, 36U, 42U, 47U Width: 600 mm Depth: 1000 mm LOAD CARRYING CAPACITY: 600 kg 600x600 - 600x800 - 600x1000 COLOUR: RAL 9005 black RAL 7035 light grey STANDARDS: ISO 9001: 2008 Quality Management Sytem ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2 KEY FEATURES • The Universal Line free standing cabinets are suitable for office, equipment room, housing server and cabling closet installations. Attention to style with attractive colours black RAL 9005 and light grey RAL 7035 and smoked glass door reinforced with vertical left and right metal frames means that cabinets can be deployed in the most demanding of office environments where appea counts. • However, Universal Line are an exceptionally sturdy and strong cabinet enabling usage for all applications. • Front door frames are available with orange decorative stripe. • The Universal Line offers a highly cost-effective and assembly-friendly solution for numerous applications in the field of network technology and electronics. The Universal Line is highly configurable to the end users requirements and provides unique features to benefit system designers, installers and network managers. • Standard cabinet is completely assembled and delivered as a single enclosure. • Side by side mounting is also possible when side panels are not used; baying kits to be added. • The rigid welded frame construction can be disassembled and assembled easily without any special tools. Thus narrow doors, staircases and elevators are no problem. 29 29
  30. 30. Universal Line free standing enclosures Universal Line free standing enclosures offer a wide range of options. 30
  31. 31. UNIVERSAL LINE FREE STANDING ENCLOSURES FOR 600x600 - 600x800 - 600x1000 EASY TO ACCESS Front door Features a full-length smoked and shatterproof glass door with decorative accent stripe reinforced with left/right metal frames and integral locking mechanism. Side doors Lockable, removable, complete with slam latches and barrel type locks. 19” mounting angles (front/2ea and back/2ea) allow for flexible configuration and are adjustable in depth. C rails 3 fold 1,5 mm thickness to increase the stability of equipment . Levelling feet included as a standard feature. Rear door Lockable, removable lock. Secure, locking front and back doors with spring loaded hinges offer best accessibility even when connecting the cabinets. The door hinge is easily swapped from one side to the other to change the direction the door opens. Giving you 4-way access to equipment. Front and rear door can be replaced giving you flexibility for different installations. CABLE ACCESS Multiple cable entry points provide maximum versatility. There is a rubber edge sliding cover mechanism that protects and fix the cables. There is a brush on the rear panel that can be positioned on top or bottom (brush entry available on height of 26 U and above) CONSTRUCTION Rigid welded frame construction in steel sheet, rapidly disassembled with 4 screws per corner. Corners of base has welded sockets that tightly fixed into the columns give maximum stability. Frames are made with a 24-fold design for increased stability. Vented Pagoda style top cover with built-in space for available top mount ventilation fan system providing protection against dust flow from the top, additionally this causes a chimney effect to provide passive air flow via convection. 31
  32. 32. Universal Line free standing SELECTION STEPS FOR 600x600 - 600x800 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U66 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U66 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U66 - M02 - F01 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U66 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page) 32
  33. 33. PART NUMBER DEFINITION FOR 600x600 - 600x800 FX MAIN PART NUMBER STRUCTURE CKR Product range Universal Line F01* Width & Depth U height + CKR Front door options - HHU - WD + HHU F02 600 600 WD 16U 20U 22U 26U 32U H 66 36U CKR H 68 39U 42U 44U Front view 47U Front view F03 CKR : Universal Line free standing product range HHU : “U” height WD : Width and depth F04 600 600 OPTIONS MX - - RX** Front door options Colour options MX FX + FX Rear door options + H H RX M01 F01* R01 M02 F02 R02 F03 * F01 is the standard front door. ** RX - R01 is standard rear door for 22U and below, is optional door for 26U and above R02 is standard rear door for 26U and above with 2 brushed cable access part Front view RX** Rear door options 300 R02 55 MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F01*= Single opening shatter proof glass door with left and right metal frame slotted, single point handled locking F02= Single opening shatter proof glass door with complete metal frame slotted, single point handled locking F03= Single opening solid metal door, single point handled locking F04= Single opening %63 perforated door with complete metal frame slotted, single point handled locking RX** : Rear door options R01= Single opening solid metal rear door with barrel type single point lock unit for 22U and below R02= Single opening solid metal rear door with barrel type single point lock unit with brushed cable entry, for 26U and above Front view R01 600 55 F04 H= Enclosure height 300 Back view Back view 33
  34. 34. Universal Line free standing TECHNICAL DRAWINGS FOR 600x600 - 16U/20U/22U R01** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 600 mm CKR16U66 16U 600x600 16 600 600 390 715 865 880 945 CKR20U66 20U 600x600 20 600 600 390 890 1042 1057 1122 CKR22U66 22U 600x600 22 600 600 390 980 1131 1146 1211 * F01 is the standard front door. ** R01 is the standard rear door for 22U and below. 34
  35. 35. TECHNICAL DRAWINGS FOR 600x600 - 16U/20U/22U 600 395 F01* (Min 30) 111 300 (Min 520) 390 478 200 H (Min 45) 95 Front view Bottom view 600 19” F02 Mounting profile H 600 600 Front view 600 F03 H Side view Front view H Back view Front view 600 600 600 F04 H Top view H= Enclosure height Iso view Front view * F01is the standard front door. 35
  36. 36. Universal Line free standing TECHNICAL DRAWINGS FOR 600x800 - 16U/20U/22U R01** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 780 mm CKR16U68 16U 600x780 16 600 780 555 715 865 880 945 CKR20U68 20U 600x780 20 600 780 555 890 1042 1057 1122 CKR22U68 22U 600x780 22 600 780 555 980 1131 1146 1211 * F01 is the standard front door. ** R01 is the standard rear door for 22U and below. 36
  37. 37. TECHNICAL DRAWINGS FOR 600x800 - 16U/20U/22U 600 F01* 395 200 (Min 30) 130 300 658 (Min 701) 555 H (Min 45) 91 Front view 600 F02 19” Bottom view Mounting profile H 600 780 Front view H 600 F03 H H Front view Side view Back view Front view 600 600 780 F04 H Top view H= Enclosure height Iso view Front view * F01is the standard front door. 37
  38. 38. Universal Line free standing TECHNICAL DRAWINGS FOR 600x600 - 26U/32U/36U/39U/42U/44U/47U R02** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 600 mm CKR26U66 26U 600x600 26 600 600 390 1160 1309 1324 1389 CKR32U66 32U 600x600 32 600 600 390 1422 1576 1591 1656 CKR36U66 36U 600x600 36 600 600 390 1603 1754 1769 1834 CKR39U66 39U 600x600 39 600 600 390 1735 1887 1902 1967 CKR42U66 42U 600x600 42 600 600 390 1868 2021 2036 2101 CKR44U66 44U 600x600 44 600 600 390 1960 2110 2125 2190 CKR47U66 47U 600x600 47 600 600 390 2093 2244 2259 2324 * F01 is the standard front door. ** R02 is the standard rear door for 26U and above. 38
  39. 39. TECHNICAL DRAWINGS FOR 600x600 - 26U/32U/36U/39U/42U/44U/47U 600 F01* 395 H (Min 520) 390 (Min 45) 95 478 200 (Min 30) 111 300 Bottom view Front view F02 600 19” Mounting profile 600 300 55 600 H Front view 600 F03 55 H Front view H 300 Back view Side view 600 Front view F04 600 600 H Top view H= Enclosure height Iso view Front view * F01 is the standard front door. 39
  40. 40. Universal Line free standing TECHNICAL DRAWINGS FOR 600x800 - 26U/32U/36U/39U/42U/44U/47U R02** F01* F02 F03 F04 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 780 mm CKR26U68 26U 600x780 26 600 780 555 1160 1309 1324 1389 CKR32U68 32U 600x780 32 600 780 555 1422 1576 1591 1656 CKR36U68 36U 600x780 36 600 780 555 1603 1754 1769 1834 CKR39U68 39U 600x780 39 600 780 555 1735 1887 1902 1967 CKR42U68 42U 600x780 42 600 780 555 1868 2021 2036 2101 CKR44U68 44U 600x780 44 600 780 555 1960 2110 2125 2190 CKR47U68 47U 600x780 47 600 780 555 2093 2244 2259 2324 * F01 is the standard front door. ** R02 is the standard rear door for 26U and above. 40
  41. 41. TECHNICAL DRAWINGS FOR 600x800 - 26U/32U/36U/39U/42U/44U/47U 395 600 F01* 200 (Min 30) 130 300 (Min 45) 91 658 (Min 701) 555 H Bottom view Front view F02 600 19” Mounting profile 780 300 55 600 H Front view 600 F03 55 H H 300 Front view Side view Back view 600 Front view F04 780 600 H Top view H= Enclosure height Iso view Front view * F01is the standard front door. 41
  42. 42. Universal Line free standing SELECTION STEPS FOR 600x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U6100 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U6100 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U6100 - M02 - F01 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U6100 - M02 - F01 - R02 (RX= Look at the RX rear door options on the next page) 42
  43. 43. PART NUMBER DEFINITION FOR 600x1000 FX MAIN PART NUMBER STRUCTURE CKR Product range Universal Line CKR Front door options - HHU - WD + HHU F05* Width & Depth U height + F06 600 600 WD 26U 6100 36U CKR 42U 47U H CKR : Universal Line free standing product range HHU : U height WD : Width and depth H Front view Front view F07 OPTIONS F08 600 600 MX - FX - RX Front door options Colour options MX + FX Rear door options + RX F05* R01 M02 F06 R02* F07 R03 F08 F04 MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F05*= Single opening tempered proof glass door with left and right metal frame slotted, single point handled locking F06= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F07= Single opening solid metal door, single point handled locking F08= Single opening %63 perforated door with complete metal frame slotted, single point handled locking RX : Rear door options R01= Single opening solid metal rear door with barrel type, single point lock unit R02*= Single opening solid metal rear door with barrel type, single point lock unit, brushed cable entry on top and bottom R03= Double opening % 63 perforated rear door with complete frame, 3 point handled locking F04= Single opening %63 perforated door with complete metal frame slotted, single point handled locking H H Front view Front view RX Rear door options R02* 300 R03 R01 F04 55 M01 Back view Back view Back view Back view H= Enclosure height * F05 and R02 are the standard doors 43
  44. 44. Universal Line free standing TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U R01 R03 F04 R02** F05* F06 F07 F08 Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line free standing cabinets 19” 600 x 1000 mm CKR26U6100 26U 600x1000 26 600 1000 740 1175 1309 1324 1389 CKR36U6100 36U 600x1000 36 600 1000 740 1620 1754 1769 1834 CKR42U6100 42U 600x1000 42 600 1000 740 1889 2021 2036 2101 CKR47U6100 47U 600x1000 47 600 1000 740 2110 2244 2259 2324 * F05 is the standard front door. ** R02 is the standard rear door for 26U and above. 44
  45. 45. TECHNICAL DRAWINGS FOR 600x1000 - 26U/36U/42U/47U 600 395 F05* 200 (Min 30) 150 300 878 (Min 921) 740 H Front view (Min 45) 106 Bottom view 1000 19” Mounting profile 300 55 600 F06 600 H Front view 600 F07 55 H Front view H 300 Back view Side view 600 Front view F08 1000 600 H Top view H= Enclosure height Iso view Front view * F05 is the standard front door. 45
  46. 46. Universal Line free standing TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 46 KEY FEATURES Main profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 45 degrees and consisting of 6 bends for each profile. In total; 24 folds provide framework stability. Tested to provide (x, y, z) axis resistance that meets EN 61587-1/5.2.1 and 5.2.2 and external impact resistance that meets EN 615871/5.3.3. Bottom and upper case have a structure which increases resistance and strength of cabinet by mono-block bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper case with screws. Cable access at bottom case has a sliding type blanking access plate that would block dust inlet. A rubber edge on the cable access plate with sliding structure, allows fixing of cables into the cabinet without any damage. Rear door is manufactured with 2 cable access parts 1 ea. with brush on top 1 ea. on bottom for 26 U and above sizes*. Rear door in standard configuration is a single opening door which is removable and lockable. For options please see the related diagrams and technical charts on pages 33-43. Side panels have a structure that can be opened and removed with slam latch and key and are lockable and removable. Front doors are a framed glass structure which is tempered, anti-static, secure and smoked glass (4 mm thickness) with a decorative stripe, according to EN 12150-1:2000 standard. Front door in standard configuration has left and right metal frame structure with high density polyurethane adhesive and screw. For front door options please see the related diagrams and technical charts on pages 33-43. Front door can be opened to 125 degrees, removable and lockable with handle type locking unit. Pagoda style vented top panel with a dedicated space of ventilation fan module system allows easy installation of max. 4 fans. 19”(inch) mounting angles (2ea. in front and 2ea. in rear) are part of the cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels. Levelling feet are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for environment with ISO 14001:2004 Environmental Management System. * Please see related diagrams to define the difference of rear door design between up to 26U and above 26U
  47. 47. TECHNICAL SPECIFICATIONS Custom number 85380000 / 85381000 / 853710990019 Shipping structure Assembled Mounting type Stand alone Load carrying capacity (kg) 600 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standard colour RAL 7035, RAL 9005 Standard stripe colour Orange IP protection standard IP20 FRONT DOOR Shatterproof glass with left and right metal frame Glass 4 mm thickness full-length smoked, shatterproof, tempered, secure Front door construction Single door opening Front door lock Handle type, single point locking Adhesive material High density polyurethane DIN 53479, DIN 53505 Hinge system Spring loaded Door opening angle and swapping 125 degree, possible to swap one side to the other SIDE PANEL Solid metal, 1 mm left and right (2ea.) Side panel construction Lockable, removable c/with slam latches and lock Side panel lock Barrel type lock unit, single point + Slam latch (2ea) REAR DOOR Solid metal, 1 mm Rear door construction Single opening, solid metal with brushed cable entry on top and bottom. Rear door lock Barrel type lock unit, single point Hinge system Spring loaded Door opening angle and swapping 125 degree, possible to swap one side to the other TOP COVER Solid metal 1 mm Top cover construction Pagoda type structure provides efficient air removal FRAMEWORK Top and bottom base units Solid metal 1,5 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 1,5 mm Uprights construction Tightly fixed into top and bottom base units 6 times folded INTERIOR PARTS 19’’ mounting angles Solid metal, 1,5 mm 3 times folded 600x600, 600x780 / 1 time folded for 600x1000 “U” marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19’’ Zinc plated, passivated, 8-12 micron. Adjustable in depth C type support rails in depth Solid metal, 1,5 mm 3 times folded, 2 ea. at left , 2 ea. at right up to 26U 3 ea. at left , 3 ea. at right 26U and higher OPTIONS For front and rear door options, please look at pages 33-43. For CUSTOMIZED PRODUCTS rather than above options, please contact sales department. 47
  48. 48. Universal Line JUMBO free standing SELECTION STEPS FOR 800x800 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U88 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U88 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U88 - M02 - F09 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U88 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page) 48
  49. 49. PART NUMBER DEFINITION FOR 800x600 - 800x800 FX MAIN PART NUMBER STRUCTURE CKR - HHU - WD Product range Universal Line CKR Width & Depth U height + HHU + F09* WD 32U F10 780 780 86 36U CKR Front door options 88 39U H H 42U 44U 47U CKR : Universal Line free standing product range HHU : “U” height WD : Width and depth Front view F11 Front view F12*** 780 R04** 780 780 OPTIONS MX - FX - RX Front door options Colour options MX + FX Rear door options + H H H RX M01 F09* R04** M02 F10 R05 F11 R06* F12*** F12*** Front view * F09 and R06 are the standard doors. ** R04 can be usable as front door also. *** F12 used as rear door as well. Front view RX R04** Rear door options R04** R06* 55 300 H 55 MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F09*= Double opening tempered proof glass door with left and right metal frame slotted, two point barrel type locking F10= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F11= Single opening solid metal door, single point handled locking F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking R04**= Double opening %63 perfore door with complete metal frame, 3 point handled locking RX : Rear door options R06*= Double opening complete metal door with brushed cable entry, barrel type single point lock unit. R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking R05= Single opening solid metal rear door with barrel type, single point lock unit F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking Front view 300 Back view R05 Back view Back view F12*** Back view H= Enclosure height 49
  50. 50. Universal Line JUMBO TECHNICAL DRAWINGS FOR 800x600 - 32U/36U/39U/42U/44U/47U F12*** R05 R04** R06* F09* F10 F11 R04** F12*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line JUMBO cabinets 19” 780 x 600 mm CKR32U86 32U 780x600 32 780 600 365 1422 1576 1591 1656 CKR36U86 36U 780x600 36 780 600 365 1603 1754 1769 1834 CKR39U86 39U 780x600 39 780 600 365 1735 1887 1902 1967 CKR42U86 42U 780x600 42 780 600 365 1868 2021 2036 2101 CKR44U86 44U 780x600 44 780 600 365 1960 2110 2125 2190 CKR47U86 47U 780x600 47 780 600 365 2093 2244 2259 2324 * F09 and R06 are the standard doors. ** R04 is usable as front door also. *** F12 is usable as rear door also. 50
  51. 51. TECHNICAL DRAWINGS FOR 800x600 - 32U/36U/39U/42U/44U/47U F09* 515 F10 780 300 478 (Min 408) 365 55 H (Min 138) 141 200 780 (Min 50) 90 300 19” Bottom view Front view Mounting profile 780 Front view F11 780 300 55 600 H H H H Front view F12 55 780 Front view 300 Side view H Back view Front view 780 R04 55 300 600 780 H Top view H= Enclosure height Iso view Front view * F09 is the standard door. 51
  52. 52. Universal Line JUMBO TECHNICAL DRAWINGS 800x800 - 32U/36U/39U/42U/44U/47U F12*** R05 R04** R06* F09* F10 F11 R04** F12*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line JUMBO cabinets 19” 780 x 780 mm CKR32U88 32U 780x780 32 780 780 550 1422 1576 1591 1656 CKR36U88 36U 780x780 36 780 780 550 1603 1754 1769 1834 CKR39U88 39U 780x780 39 780 780 550 1735 1887 1902 1967 CKR42U88 42U 780x780 42 780 780 550 1868 2021 2036 2101 CKR44U88 44U 780x780 44 780 780 550 1960 2110 2125 2190 CKR47U88 47U 780x780 47 780 780 550 2093 2244 2259 2324 * F09 and R06 are the standard doors. ** R04 is usable as front door also *** F12 is usable as rear door also. 52
  53. 53. TECHNICAL DRAWINGS FOR 800x800 - 42U/47U 515 300 (Min 40) 95 F10 780 (Min 720) 550 780 H H (Min 130) 131 658 300 85 300 F09* Front view 19” Bottom view Mounting profile Front view F11 780 780 300 55 780 H H H Front view F12 55 780 Front view 300 Side view Back view H 780 Front view R04 55 780 300 780 H Top view H= Enclosure height Iso view Front view * F09 is the standard front door. 53
  54. 54. Universal Line JUMBO free standing SELECTION STEPS FOR 800x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part number structure’’ and ‘’Options’’ sections. The below example explains how to select the right options for your needs. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: CKR42U8100 Step 2 Please choose the colour from the table and place it after the part number. For example: CKR42U8100 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: CKR42U8100 - M02 - F09 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: CKR42U8100 - M02 - F09 - R06 (RX= Look at the RX rear door options on the next page) 54
  55. 55. PART NUMBER DEFINITION FOR 800x1000 FX MAIN PART NUMBER STRUCTURE CKR - HHU - WD Product range Universal Line CKR Front door options Width & Depth U height + HHU + WD H H Front view 780 47U CKR : Universal Line product range HHU : “U” height WD : Width and depth OPTIONS F10 780 8100 42U CKR F09* F11 Front view F12*** 780 R04** 780 780 MX - FX - RX Front door options Colour options MX + FX Rear door options + H RX M01 F09* R04** M02 F10 R05 F11 R06* F12 H F12*** Front view Front view Front view R04** RX MX : Colour options M01= RAL 9005 black M02= RAL 7035 light grey FX : Front door options F09*= Double opening tempered proof glass door with left and right metal frame slotted, two point barrel type locking F10= Single opening tempered proof glass door with complete metal frame slotted, single point handled locking F11= Single opening solid metal door, single point handled locking F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking RX : Rear door options R05= Single opening solid metal rear door with barrel type, single point lock unit R04**= Double opening %63 perforated door with complete metal frame, 3 point handled locking R06*= Double opening complete metal door with brushed cable entry, barrel type single point lock unit. F12***= Single opening %63 perforated door with complete metal frame slotted, single point handled locking Rear door options * F09 and R06 are the standard doors ** R04 is usable as front door also. *** F12 is usable as rear door also. R04** R06* 55 300 55 H 300 Back view R05 Back view Back view F12*** Back view H= Enclosure height 55
  56. 56. Universal Line JUMBO TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U F12*** R05 R04** R06* F09* F10 F11 R04** F12*** Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) Universal Line JUMBO cabinets 19” 780 x 1000 mm CKR42U8100 42U 780X1000 42 780 1000 740 1889 2021 2036 2101 CKR47U8100 47U 780X1000 47 780 1000 740 2110 2244 2259 2324 * F09 and R06 are the standard doors. ** R04 is usable as front door also. *** F12 is usable as rear door also. 56
  57. 57. TECHNICAL DRAWINGS FOR 800x1000 - 42U/47U 515 300 (Min 26) 120 F10 780 780 (Min 852) 740 (Min 118) 136 878 300 85 300 F09* Bottom view H H Front view 19” Mounting profile Front view F11 780 780 1000 55 300 H H H Front view 55 F12 780 300 Front view Side view Back view H 780 Front view R04 780 1000 300 55 H Top view H= Enclosure height Iso view Front view * F09 is the standard front door. 57
  58. 58. Universal Line JUMBO TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1 / 4.2, IEC60068-2, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1 / 4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49, IEC60068-2-I, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587- / 5.3.3, IEC60917, C60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and flame resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC-01 6112 , 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 58 KEY FEATURES Main profile (framework) has an aesthetic structure which increases mechanical resistance, folded at an angle of 45 degrees and consisting of 6 bends for each profile. In total; 24 folds provide framework stability.Tested to provide (x, y, z) axis resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Bottom and upper case have a structure to increase resistance and strength of cabinet by mono block bended, welded and profile-interlocking design. Profiles are manufactured to interlock bottom and upper case with screws.The bottom case providing cable access is fitted with a sliding blanking access plate to prevent dust. A rubber edge on the cable access plate and sliding structure, allows cables to be placed into the cabinet and fixed inside with no damage. Additionally both on top and bottom, there are brushed cable entry plates for mass cabling needs. Rear door is manufactured with 2 cable access part top/ bottom with brush. Rear door in standard configuration is a double opening door which is removable and lockable. For options please see the related diagrams and technical charts in pages 4955. Side panels have a structure that can be opened and removed with slam latch and key and are lockable and removable. Front doors are a framed glass structure which is tempered, anti-static, secure and smoked glass (4 mm thickness) with a decorative stripe, according to EN 12150-1:2000 standard. Front door in standard configuration has left and right metal frame structure with high density polyurethane adhesive and screw and double opening. For options please see the related diagrams and technical charts in pages 49-55. Front door is a double openning door which can be opened to 125 degrees, removable and lockable with handle type locking unit. Pagoda style vented top panel with a dedicated space of ventilation fan module system allows easy installation of max. 4 fans. 19”(inch) mounting angles (2 ea. in front and 2 ea. in rear) are part of the cabinet interior configuration and adjustable in depth. Baying is possible for side by side applications without side panels.. Levelling feet are standard in shipping configuration. The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards, RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for enviroment with ISO 14001: 2004 Environmental Management System.
  59. 59. TECHNICAL SPECIFICATIONS Custom number 85380000 / 85381000 / 853710990019 Shipping structure Assembled Mounting type Stand alone Load carrying capacity (kg) 600 Certification on product TSE, Gost Surface finish Electrostatic powder coated c/with surface treatment , 80 +/ - 5 micron paint thickness and tested according to IEC 60068-21,2-2, 2-30,2-42, 2-43, 2-49, 2-11 STANDARD PRODUCT Standard colour RAL 7035, RAL 9005 Standard stripe colour Orange Baying Possible with baying kit for side by side applications without side panels IP protection standard IP20 FRONT DOOR Shatterproof glass with left and right metal frame Glass 4 mm thickness full-length smoked, shatterproof, tempered, secure Front door construction Double opening door Front door lock 2 point locking barrel type Adhesive material High density polyurethane DIN 53479, DIN 53505 Hinge system Spring loaded Door opening angle and swapping 125 degree SIDE PANEL Solid metal, 1 mm left and right (2 ea.) Side panel construction Lockable, removable c/with slam latches and lock Side panel lock Barrel type lock unit, single point + Slam latch (2 ea) REAR DOOR Solid metal, 1 mm Rear door construction Double door opening, lockable, removable Rear door lock Barrel type lock unit, single point Hinge system Spring loaded Door opening angle and swapping 125 degree TOP COVER Solid metal 1,2 mm Top cover construction Pagoda type, allows efficient air removal FRAMEWORK Top and bottom base units Solid metal 1,5 mm Top and bottom base units construction Completely welded corner socket system Uprights Solid metal, 1,5 mm Uprights construction Tightly fixed into top and bottom base units 6 times folded INTERIOR PARTS 19’’ mounting angles Solid metal, 1,5 mm 3 times folded 800x600, 800x800 / 1 time folded for 800x1000 “U” marking available 2 ea. at rear, 2 ea. at front Pre-configured as 19’’ Zinc plated, passivated, 8-12 micron. Adjustable in depth Omega type support rails in depth Solid metal, 1,5 mm 3 times folded 2 ea. at left , 2 ea. at right up to 26U 3 ea. at left , 3 ea. at right 26U and higher OPTIONS For the front and rear door options, please look at pages 49-55. For CUSTOMIZED PRODUCTS rather than above options, please contact sales department. 59
  60. 60. Universal Line JUMBO Accessories SPECIAL ACCESSORIES* FOR JUMBO Teleskopic cable trunking Designed to protect and hide cable bundles coming from the ceiling. Since the height between ceiling and cabinet is variable, it is manufactured as telescopic to fit all dimensions. Coming complete with cover which when closed gives a professional look. Vertical cable management channels (left and right) Designed to manage large patch cable bundles in front of the cabinet. It is installed through the height of the cabinet, and each “U” dimension, there is a hole to pass horizontal patch cables on vertical axis. A spring hinged cover in front of the vertical cable management panel integral with slam latch.The cover protect and hide all cable bundles. When it is closed, it gives a professional look. Labour costs are reduced by %20 and is a time saving system. Vertical cable management trunking Designed to carry large cable bundles through the vertical axis of the cabinet. From top to bottom, it is continuous with the height of cabinet. Bottom edge of the trunking fits into the cabinet bottom cable entry, top edge of the trunking fits into the cabinet top cable entry. It has holes for cable access for horizantal axis. It is punched in a shape to tie the cables. Since it has a sliding cover on the trunking, cable bundles are hidden and protected. When closed, it offers a chic looking finish. *See accessories for product part numbers, definitions and please contact sales department. Professional cabling solutions with JUMBO Left and right cable management panels hide and protect all networking cables as well as providing a professional looking finish. Double opening rear doors provide space saving between cabinet and wall. 60
  61. 61. UNIVERSAL LINE JUMBO FEATURES Perforated, vented Pagoda-style top providing maximum protection against dust Front door with integrated locking mechanism for added security. Side panel comes with snap closures and locks providing security, whilst allowing four-way access to the equipment. Sliding access panel on the bottom for cable entry and a brush entry on the rear panel that can be positioned on the top or bottom 61
  62. 62. Universal Line PCcase free standing 600x800 - 36U STANDARD DIMENSIONS: Height: 36U Width: 600 mm Depth: 780 mm STANDARDS: ISO 9001: 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipments) Overall cabinet dimensions to IEC 297-2 COLOUR: RAL 9005 black RAL 7035 light grey • 19” • FITS YOUR DECOR AND ENVIRONMENT • SECURE AND STURDY • EASY TO MAINTAIN AND LARGE INNER VOLUME • DUST PROOF • AIR CIRCULATION WITH VENTED FILTERS 62 PCcase is ideal for office, factory, workshop, storage, store, gas stations and laboratories etc. as server housing. It protects your servers and devices against dust, humidity, hot/cold air but most important that against unauthorized peoples. Servers, all kind of PC’s, monitors, keyboards, UPS’s, switches and networking products can easily be placed in it. Its agronomy provides the keyboards at hands level and monitor is at eye level.
  63. 63. 600x800 - 36U FEATURES PCccase cabinets match all features defined for Universal Line as main construction. It has 3 sections; 1st compartment: Screen section 11U space covered, (not 19’’, equipped with a fixed shelf which should be base for the screen unit). 2nd Compartment: Keyboard section 3U space covered (not 19’’, equipped with a specific sliding shelf integrated with mouse housing and platform). 3rd Compartment: Device section 19” 22U usable (19’’, 22U rail allowing use of all standard accessories to mount all kind of devices printers, UPS, server or any LAN/WAN devices...) All compartments are lockable. Both side doors are lockable, removable, and openable. Side doors have filtered and vented air circulation trays that allow air circulation or air entry. It is possible to use together with cooling fans which also has filtered and vented tray on top that allow air circulation. Bottom section has two door options: Glass door or solid metal door. 63
  64. 64. Universal Line PCcase TECHNICAL DRAWINGS 600x800 - 36U Exploded view Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) 36U 600x780 mm PCcase, metal door section at bottom Height: vertical mounting profile (mm) PCCASE36M Depth: max mounting profile (mm) 36U 600x780 mm PCcase, glass door section at bottom Depth: overall (mm) PCCASE36 64 Product definition (mm) Width: overall (mm) Part number U Size Universal Line PCcase cabinets 19” 600 x 780 mm 36 600 780 555 1603 1766 1781 1846
  65. 65. TECHNICAL DRAWINGS FOR 600x800 - 36U 395 600 (Min 30) 91 1746 (Min 701) 555 658 200 (Min 30) 130 300 19” Bottom view Mounting profile 600 780 1746 Front view with glass door 600 Front view Side view Back view 1746 600 780 302 350 Front view with metal door Top view Iso view 65
  66. 66. Universal Line free standing accessories FREQUENTLY USED ACCESSORIES SELECTION TABLE FOR Universal Line Estap has a wide range of accessories: Fixed shelves, heavy duty fixed shelves, sliding shelves, fans, cooling units, vertical cable managements, cable rings, organisers, trays, plinth and so on... * See the other accessories and part number definitions on pages 173-213. * Please state colour choice in your orders. M01=RAL 9005 black and M02= RAL 7035 light grey Frequently used accessories selection table Universal Line / Shelves part numbers Fixed shelves Enclosure Sizes* PCcase 600x800 600x1000 800x600 800x800 800x1000 M44SBR80 M44SBR60 M44SBR80 M44SBR100 M44SBR60 M44SBR80 M44SBR100 Heavy duty fixed shelves Sliding shelves 600x600 - - - M55SR720 M44HRK80 M44HRK60 M44HRK80 Heavy duty sliding shelves - - - - - - M44HRK60 M44HRK80 M55HR720 M55SR720 - - - M55HR720 Universal Line / Fan units part numbers PCcase 600x600 600x800 600x1000 800x600 800x800 800x1000 2 Fan unit with on/off switch M44HV2F M44HV2F M44HV2F M44HV2F M44HV2F M44HV2F M44HV2F 4 Fan unit with on/off switch M44HV4F M44HV4F M44HV4F M44HV4F M44HV4F M44HV4F M44HV4F 2 Fan unit with thermostat unit M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT M44HV2FT 4 Fan unit with thermostat unit M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT M44HV4FT Universal Line / Cable management part numbers 1U cable management panel (5 rings) Vertical cable management Universal Line / PDU part numbers Enclosure Sizes* Enclosure Sizes* PCcase 600x600 600x800 600x1000 800x600 E44ORG1U E44ORG1U E44ORG1U E44ORG1U E44ORG1U - - - - 800x800 800x1000 E44ORG1U E44ORG1U M44ORGxxU M44ORGxxU M44ORGxxU Enclosure Sizes* PCcase 600x600 600x800 600x1000 800x600 800x800 800x1000 6 way PDU with 1x16A CCT breaker,1U M446AL M446AL M446AL M446AL M446AL M446AL M446AL 9 way PDU with 1x16A CCTbreaker, 2U M449ALC M449ALC M449ALC M449ALC M449ALC M449ALC M449ALC 800x600 800x800 800x1000 Universal Line / Castor part numbers Castor group Fixings/ cagenut, screw, washer (1set=20 pcs.) 66 Enclosure Sizes* PCcase 600x600 600x800 600x1000 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 M22TKGR1 KFS6X15 * Please check drawing pages for cabinet sizes. KFS6X15 KFS6X15 KFS6X15 KFS6X15 KFS6X15 M22TKGR1 KFS6X15
  67. 67. EUROline free standing Reduce %ip5e0t sh m n * cost • Real flatpack design • Max. 10 min** for assembly • Easy to carry and transport • Easy to maintenance • High volume capacity for large cable bundles * Mixed quantity and mixed size ** Measured values by Estap. It can change according to size of the enclosure 67
  68. 68. EUROline free standing 600x600 - 600x800 - 600x1000 - 800x600 - 800x800 - 800x1000 EUROline free standing enclosures 22U 26U 32U 36U 42U 600 x 600* 42U 600 x 1000* 32U 36U 42U 800 x 800* 42U 800 x 1000* 600 x 800* Openable, lockable, removable side panels, front and rear doors • 19” • MODULAR STRUCTURE • READY FOR ASSEMBLY • STURDY, RUGGED STEEL CONSTRUCTION • REDUCE THE SHIPMENT COST • FLATPACK * Please check drawing pages for cabinet sizes. 68
  69. 69. 600x600 - 600x800 - 600x1000 - 800x800 - 800x1000 STANDARD DIMENSIONS: Heights: 22U, 26U, 32U, 36U, 42U Width: 600 mm Depth: 645 mm and 825 mm LOAD CARRYING CAPACITY: 400 kg Heights: 42U Width: 600 mm Depth: 1005 mm RAL 7035 light grey Heights: 32U, 36U, 42U Width: 780 mm Depth: 825 mm Height: 42U Width: 780 mm Depth: 1005 mm COLOUR: RAL 9005 black STANDARDS: ISO 9001: 2008 Quality Management Systems ISO 14001: 2004 Environmental Management System 19” mounting to IEC 297-1 EN 61587-1 mechanical structures (cabinets for electronic equipment) Overall cabinet dimensions for IEC 297-2 KEY FEATURES • High quality production • Aesthetic look • Sturdy, rugged steel construction • Openable, lockable, removable side panels, front and rear doors. • Secure, tempered front door, with left&right metal frames, and handle type lock. • Easy to maintain, high volume capacity for large cable bundles. • Upper case is suitable for fan units and brushed cable entry. • Welded corners and sturdy construction. • Bottom case is completely open for large cable entries. Bottom plate with sliding type Estap standard cable entry, can be used to close case. • Rugged steel for 19” mounting angles • Reduce shipment costs %50* • Easy to transport • Strong protection against transport damages • Easy to assemble • After mounting, cardboard packaging and wooden pallets may be retained and reused for future shipments. * Mixed quantity and mixed size 69
  70. 70. EUROline free standing SELECTION STEPS FOR 600x600 - 600x800 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and ‘’Options’’ sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: EU42U68 Step 2 Please choose the colour from the table and place it after the part number. For example: EU42U68 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: EU42U68 - M02 - F18 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: EU42U68 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page) 70
  71. 71. PART NUMBER DEFINITION 600x600 - 600x800 FX MAIN PART NUMBER STRUCTURE EU Front door option - HU - WD H Product range EUROline EU Width & depth U height + HHU 22U + F18 WD 66 68 26U EU 600 32U 36U 42U EU : EUROline free standing product range HHU : “U” height WD : Width and depth H OPTIONS MX - FX - RX Front door option Colour MX M01 + FX F18 Rear door option + RX Front view R10 RX M02 Rear door option 600 R10 MX : Colour options RAL 9005 black M01= RAL 7035 light grey M02= FX : Front door option Single opening shatter proof glass door with left F18= and right metal frame slotted, single point handled locking H RX : Rear door option Single opening solid metal rear door with R10= barrel type lock unit, single point H= Enclosure height Back view 71
  72. 72. EUROline free standing TECHNICAL DRAWINGS FOR 600x600 - 22U/26U/32U/36U/42U R10 F18 * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 600 x 645 mm EU22U66 22U 600x645 22 600 645 331,5 1070 1135 1150 1215 EU26U66 26U 600x645 26 600 645 331,5 1245 1310 1325 1370 EU32U66 32U 600x645 32 600 645 331,5 1515 1575 1590 1655 EU36U66 36U 600x645 36 600 645 331,5 1700 1755 1770 1825 EU42U66 42U 600x645 42 600 645 331,5 1960 2025 2040 2105 * Bottom cover plate is an optional accessory. 72
  73. 73. TECHNICAL DRAWINGS FOR 600x600 - 22U/26U/32U/36U/42U F18 600 H (Min 93,5) 155 566 (Min 455) 331,5 (Min 91,5) 153 521 19” Bottom view* Note: *Bottom is empty, the top of the Front view Mounting profile enclosure appears 600 645 566 521 300 200 H Bottom view* Note: * Bottom cover plate is an optional accessory Side view 645 600 300 Back view 72 Front view Top view H= Enclosure height Iso view 73
  74. 74. EUROline free standing TECHNICAL DRAWINGS FOR 600x800 - 22U/26U/32U/36U/42U R10 F18 * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 600 x 825 mm EU22U68 22U 600x825 22 600 825 511,5 1070 1135 1150 1215 EU26U68 26U 600x825 26 600 825 511,5 1245 1310 1325 1395 EU32U68 32U 600x825 32 600 825 511,5 1515 1575 1590 1655 EU36U68 36U 600x825 36 600 825 511,5 1700 1755 1770 1840 EU42U68 42U 600x825 42 600 825 511,5 1960 2025 2040 2110 * The bottom cover plate is an optional accessory. 74
  75. 75. TECHNICAL DRAWINGS FOR 600x800 - 22U/26U/32U/36U/42U 521 F18 (Min 635) 511,5 746 (Min 91,5) 153 600 (Min 91,5) 153 H 19” Bottom view* Mounting profile Note: * Bottom is empty, the top of the enclosure appears 521 825 746 200 600 Front view 300 H Bottom view* Note: * Bottom cover plate is an optional accessory Side view Front view Back view 825 72 600 300 Top view H= Enclosure height Iso view 75
  76. 76. EUROline free standing SELECTION STEPS FOR 600x1000 STEPS TO SELECT THE RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section in the catalogue, has a ‘’Main part numbers’’ and ‘’Options’’ sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 - Please choose product part number. For example: EU42U61 Step 2 - Please choose the colour from the table and place it after the part number. For example: EU42U61 - M02 (MX=Look at the MX colour options on the next page) Step 3 - Please choose the front door from the table and place it after MX colour. For example: EU42U61 - M02 - F18 (FX= Look at the FX front door options on the next page) Step 4 - Please choose the rear door from the table and place it after FX front door option. For example: EU42U61 - M02 - F18 - R10 (RX= Look at the RX rear door options on the next page) 76
  77. 77. PART NUMBER DEFINITION FOR 600x1000 FX MAIN PART NUMBER STRUCTURE Front door options EU - HHU - WD Product range EUROline EU Width & depth U height + EU HHU + WD 600 61 42U EU : EUROline free standing product range HHU : “U” height WD : Width and depth F21 600 F18* H H OPTIONS MX - FX - RX Front door options Colour options MX + FX Front view Front view Rear door options + RX M01 F18* R10** M02 F21 R07 RX RX Rear door options Rear door options MX : Colour options RAL 9005 black M01= RAL 7035 light grey M02= FX : Front door options Single opening shatter proof glass door with F18*= left and right metal frame slotted, single point handled locking Single opening %63 perforated front door, F21= full slotted frame, single point handled locking RX : Rear door options Single opening solid metal rear door with R10**= barrel type lock unit, single point locking Double opening complete framed % 63 R07= perforated front door, 3 point handled locking 600 R10** 600 H Back view R07 H Back view H= Enclosure height H= Enclosure height * F18 is the standard front door. ** R10 is the standard rear door. 77
  78. 78. EUROline free standing TECHNICAL DRAWINGS FOR 600x1000 - 42U R07 R10** F21 F18* Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 600 x 1005 mm EU42U61 42U 600x1005 42 600 1005 702,5 1960 2025 2040 2110 * F18 is the standard front door. ** R10 is the standard rear door. 78
  79. 79. TECHNICAL DRAWINGS FOR 600x1000 - 42U 600 522 (Min 85,5) 147 522 (Min 825,5) 702,50 926 463 (Min 86,5) 148 F18* Bottom view* Note: *Bottom is empty, the top of the enclosure appears H 19” Mounting profile 600 Front view 1005 600 H F21 H Side view Front view Back view Front view 600 1005 72 300 Top view Iso view H= Enclosure height * F18 is the standard front door. 79
  80. 80. EUROline free standing SELECTION STEPS FOR 800x800 - 800x1000 STEPS TO SELECT RIGHT FREE STANDING ENCLOSURE In addition to Estap product part numbers, the options mentioned on the next page are to supply the right definition to meet your requirements. Each wall mounted and free standing enclosure section on the catalogue, has a ‘’Main part numbers’’ and ‘’Options’’ sections. The below example explains how to select the right options. The product part number has the below structure: P roduct range name + U height (HHU) + Width&Depth (WD) + Rear door option (RX) The product options have the below structure: C olour option (MX) + Front door option (FX) HOW TO SELECT THE OPTIONS Step 1 Please choose product part number. For example: EU42U88 or EU42U81 Step 2 Please choose the colour from the table and place it after the part number. For example: EU42U88 - M02 (MX=Look at the MX colour options on the next page) or EU42U81 - M02 (MX=Look at the MX colour options on the next page) Step 3 Please choose the front door from the table and place it after MX colour. For example: EU42U88 - M02 - F20 (FX= Look at the FX front door options on the next page) or EU42U81 - M02 - F20 (FX= Look at the FX front door options on the next page) Step 4 Please choose the rear door from the table and place it after FX front door option. For example: EU42U88 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) or EU42U81 - M02 - F20 - R12 (RX= Look at the RX rear door options on the next page) 80
  81. 81. PART NUMBER DEFINITION 800x800 - 800x1000 FX MAIN PART NUMBER STRUCTURE EU - HHU - WD Product range EUROline EU Width & depth U height + HHU 32U Front door options + 780 H H 81 EU : EUROline free standing product range HHU : “U” height WD : Width and depth Front view Front view RX OPTIONS MX - FX - Rear door options RX 780 Front door options Colour options MX + FX F19* 88 42U 42U 780 WD 36U EU F20** R12*** Rear door options + RX M01 F20** R12*** M02 F19* R11 R08* R08* H F19* MX : Colour options RAL 9005 black M01= RAL 7035 light grey M02= Back view 780 FX : Front door options Double opening shatter proof glass door with F20**= left and right metal frame slotted, 3 point handled locking Single opening %63 perforated front door, F19= full slotted frame, single point handled locking Double opening complete framed %63 R08*= perforated front door, 3 point handled locking RX : Rear door options Double opening metal rear door with R12***= 3 point handled locking Single opening solid metal rear door with R11= barrel type lock unit, single point lock unit Double opening complete framed %63 R08*= perforated front door, 3 point handled locking F19*= Single opening %63 perforated front door, full slotted frame, single point handled locking H Back view R08* 780 H H= Enclosure height * R08 and F19 can be used as both front and rear door. ** F20 is the standard front door. *** R12 is the standard rear door. R11 Back view 81
  82. 82. EUROline free standing TECHNICAL DRAWINGS FOR 800x800 - 32U/36U/42U F19** R08** R11 R12**** F19** F20*** R08** * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 780 x 825 mm EU32U88 32U 780x825 32 780 825 511,5 1515 1525 1540 1655 EU36U88 36U 780x825 36 780 825 511,5 1630 1755 1770 1840 EU42U88 42U 780x825 42 780 825 511,5 1960 2025 2040 2110 * The bottom cover plate is optional. ** R08 and F19 can be used as both front and door rear door. *** F20 is the standard front door. **** R12 is the standard rear door. 82
  83. 83. TECHNICAL DRAWINGS FOR 800x800 - 32U/36U/42U 780 F20* 701 (Min 725) 511,5 H (Min 47,5) 154 776 746 (Min 44,5) 151 513 19” Bottom view* Mounting profile Note: *Bottom is empty, the top of the Front view enclosure appears 780 701 825 780 F19 200 300 746 H H Bottom view Note: Bottom cover plate is an optional accessory Front view Side view Back view Front view 780 Top view H= Enclosure height 747 300 300 R08 72 702 H Iso view Front view * F20 is the standard front door. 83
  84. 84. EUROline free standing TECHNICAL DRAWINGS FOR 800x1000 - 42U F19** R08** R12**** R11 F19** F20*** R08** * Exploded view Part number Product definition (mm) U Size Width: overall (mm) Depth: overall (mm) Depth: max mounting profile (mm) Height: vertical mounting profile (mm) Height: without levelling feet (mm) Height: with levelling feet (mm) Height: with casters (mm) EUROline free standing cabinets 19” 780 x 1005 mm EU42U81 42U 780x1005 42 780 1005 704,5 1960 2025 2040 2110 * The bottom cover plate is optional. ** R08 and F19 can be used as both front and door rear door. *** F20 is the standard front door. **** R12 is the standard rear door. 84
  85. 85. TECHNICAL DRAWINGS FOR 800x1000 - 42U 701 513 780 H (Min 40) 146,5 926 (Min 784,5) 704,50 (Min 40) 146,5 F20* Bottom view* Note: *Bottom is empty, the top of the enclosure appears 19” Mounting profile Front view 1005 780 780 F19 H H Front view Side view Back view 780 702 Front view 780 R08 72 300 H 300 927 1005 55 H= Enclosure height Top view Iso view Front view * F20 is the standard front door. 85
  86. 86. EUROline free standing TECHNICAL SPECIFICATIONS TESTS AND CERTIFICATIONS Environment EN61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, IEC60917 and IEC60297 Industrial environment EN61587-1/4.3, IEC60068-2-42, IEC60068-2-43 and IEC60068-2-49,IEC60068-2-1, IEC60917 and IEC60297 Statical mechanical structure load test EN61587-1 / 5.2.1, IEC60917 and IEC60297 Statical mechanical structure stability EN61587-1 / 5.2.2, IEC60917 and IEC60297 Dynamic load, vibration and mechanical stroke EN61587-1 / 5.3.1, EN61587-1 / 5.3.3, IEC60917, IEC60297, IEC62208 Grounding continuity EN61587-1 / 6.2, IEC60917 and IEC60297 Fire and Flame Resistance EN61587-1 / 6.3, IEC60917 and IEC60297 Corrosion ISO9227 and ASTM B 117-85, IEC60917 and IEC60297 IP protection degree IP00.When bottom cover plate is used, it becomes IP20 IP20 accordingly EN61587-1 / 6.4, IEC60529, IEC60917 and IEC60297 Transportation ETS300019-1-2 Class2.3 Storage ETS300019-1-1 Class1.2 Security EN60950_LVD PURCHASED PRODUCT CERTIFICATIONS Sheet steel DIN EN 10130 – 99 Ereğli DC- 01 6112, 7122, RoHS Electrostatic powder coating ISO 9001, ISO 2178, ISO 2813, ISO 6272, ISO 8130-5, ISO 8130-3, RoHS Fan ISO 9001, CE (89/336/EEC EMC, 73/23/EEC LVD), RoHS Glass ISO 9001, EN 12150 – 1: 2000 tempered and secure Fixings DIN 7985, DIN 965, DIN 7981, DIN 934, DIN 985, DIN 933, RoHS Castors TS EN 12530, TS EN 12532, RoHS Lock DIN 1743, DIN 53571, RoHS 86 KEY FEATURES Main profile vertical (framework) has a structure which increases mechanical resistance with aesthetic appearance and a specially closed profile system of 30x30 mm from automation industry. Folded with an angle of 90 degree:The corner joints are welded with 4 fold connection brackets.The main profile vertical (framework) connects to top and bottom case with heavy duty 5 fold bended profile system. A total of 20 folds provide stability for the top and bottom case. Additionally, at 600x1000 and 800x1000 mm sizes a 5 fold (bend surface) bracket system provides additional stability, providing a 25 fold (bent surface) design criteria for the frame. Manufactured and tested to provide axial (x, y, z) resistance that meets EN 61587-1 / 5.2.1 and 5.2.2, and external impact resistance that meets EN 61587-1 / 5.3.3. Using a folded profile system for structure, the bottom and upper case are connected to the vertical profile system using heavy duty screws which provide modularity. Bottom case if fully open for large cable bundles to be placed; if required to close the bottom, a cover plate can be purchased as an optional accessory with sliding type edged cable entry panel. The rubber edge on the cable access plate and sliding structure, allows cables to be placed into the cabinet and fixed inside with no damage. For W=600 mm enclosure rear door is single solid metal, removable and lockable. Integral locking is single point barrel type locking system. For W=800 mm enclosure rear door in double opening, complete metal and 3 point handled locking. For options please see the related diagrams and technical charts On pages 71-77-81. Rear doors can be opened up to 220 degrees. Side panels have a structure that can be opened and removed with a key and are lockable and removable. Side panels are consist of 2 piece side panels on each side for D=1000 mm range due to easy handling and maintanence needs. Original functional side panel is lockable and removable as mentioned above; the smaller side panel is fixed from inner side with screws.Within this engineering construction the original functional side panel becomes easy to carry while installation and maintanance is in process. Front doors are single opening, left and right metal framed glass door, single point handled locking on the W=600 mm series, front doors are double opening, left and right metal framed glass door, 3 point handled locking on the W=800 mm series, front door can be opened up to 220 degrees, removable and lockable with handle type locking unit. For options please see the related diagrams and technical charts on pages 71-77-81. Vented top panel housing with a dedicated space for ventilation, fan module system allows easy installation of max. 4 fans from top. 19”(inch) mounting angles (2 ea. in front and 2 ea. in rear) are part of cabinets interior configuration and adjustable in depth. Baying is possible for side by side applications. Levelling feet are standard in shipping configuration.The cabinet meets EN 61587-1, IEC 60917, IEC 60297 standards RoHS compliancy, Gost and TSE certified. Cabinets are manufactured in our factory which has ISO 9001: 2008 Quality Assurance System and our responsibility for environment with ISO 14001:2004 Environmental Management System.

×