1. BBD4200
BBD4200
Explosion Proof Marker Light
Explosion Proof Marker Light
Guidance sign
Application
It is ideal for any potential inflammable and explosive places like
petroleum exploration, chemical industry, military industry, etc. As
Emergency exit indication or indicate lighting when power off.
IP65
1. Dangerous places in Zone 1, Zone 2.
EXIT
A
2. Grade IIA, IIB or IIC explosive gas environment or flammable dust
environment;
EXIT
EXIT
EXIT
F
E
B
-20 C
3. Dangerous dust atmosphere in Zone 20, Zone21or Zone22.
EXIT
+40 C
D
C T6
I
H
EXIT
EXIT
Explosive-proof grade: Ex d
EXIT
G
Characteristics of Performance
Explosion Proof design
EXIT
EXIT
C
EXIT
EXIT
M
J
N
Automatic emergency function; Lighting time in emergency is 3hours
Energy-saving, maintenance free.
EXIT
The shell is made of light alloy. The well designed structure ensures its
characteristics of dust proof, waterproof as well as impact resistant. All
of them make the light maintenance free .
K
S T AI R
EXIT
L
O
Field effect luminescent crystal technic.
Installation type: ceiling mounted wall-mounted type.
It adopts electro-static spraying treatment. which make sure the lamp
for safe use in all kinds of harsh atmosphere.
Dimension and Installation Type
112
210
Parameter
Unit
220V
Normal
V
Emergency
DC3.2
401
1
Normal
Light source power
353
W
Emergency
1
min
Input cable diameter
mm
Dimension
mm
Weight
Kg
(B)
180
10
270
14
324
120
80
3.8
358
Emergency lighting time
120
Voltage
318
Specification
357
Main parameter
Ordering reference
353
Ordering reference
Light Source
Rated Wattage (W)
Luminous flux (lm)
Average Useful Time (h)
BBD4200
LED
1
80
50000
(X)
2. BC9101A, BC9101B
Emergency LED Explosion proof Light
Application
LED
BC9101A, BC9101B
Emergency LED Explosion proof Light
Ordering reference
The BC9101AB Series are approved for save use as emergency lamps in
potentially explosive atmospheres such as petrol station, oil field,
metallurgy, power station etc.
IP66
BC9101A-L40-L15
Characteristics of performance
LED
BC9101A-L60-L15
-40 C
With its reflector which have different angles design, it efficiently
utilize the light. Have a good performance of illuminance uniformity,
glare free, can avoid eyestrain to the worker.
+50 C
It adopts American CREE LED as light source, can save 60% or more
on energy than the metal halide lamp
The housing is especially designed to dissipate heat, which increase the
efficiency and lifespan of the LED, so that to ensure the 100,000 hours
LED lifespan.
Ex Code: Ex d IIB T6 Gb
Standard: GB3836.1, GB3836.2
IEC60079-1:2007,MOD
BC9101 uses Taiwan Meanwell electrical appliance which's lifespan is
top ranking in the world, power factor:0.98, has a highly stable
performance.
The adjustable locking device on the bracket can tightly fix the lamp to
any desired angle, making the lamp resist to harsh vibration
BC9101B-L15
Only Emergency
LED
BC9101A-L25-L25
BC9101A-L40-L25
Normal illuminate
+ Emergency
LED
BC9101A-L60-L25
BC9101B-L25
Only Emergency
LED
Emergency
Luminous Flux(lm)
Replace
25W
120
2,134
35W
15W
40W
120
2,134
35W
60W
120
2,134
35W
15W
/
120
2,134
35W
25W
70
3,300
70W
25W
40W
70
3,300
70W
25W
Normal illuminate
+ Emergency
Emergency
Duration (minute)
25W
BC9101A-L25-L15
Normal illuminate
Wattage (W)
15W
Light Source
Emergency
Wattage (W)
15W
Type
Model No.
60W
70
3,300
70W
25W
/
70
3,300
70W
Remark:
BC9101A: Under normal condition, BC9101A will use normal external power to illuminate (its rated power can be made to 25w 40w 60w).
In the case of power outrage or in any situation where power is interrupted, this unit will automatically switch to battery backup ( lamp
wattage can be made to 15w 25w under emergency mode) which will power the unit for 120 or 70 minutes (15w: 120minutes, 25w:
70minutes).
BC9101B is only applied for emergency lighting when power outrage, and on normal condition it is off.
The anti corrosion, abrasion proof, power coated cover which is dust
proof, water proof , make the lamp an excellent option for all kinds of
high stress environment.
If emergency switch is needed, please add "-K" behind the model No. for example: BC9101A-25-L25-K
Multiple mounting options including ceiling, pendent, wall etc.
Drawing of dimension(Dimensions in mm)
Adjustable mounting bracket enable the operator to choose mounting
angle within 90 .
326
The lamp can parallel connected , no need to use the junction box.
83
363
323
325
Main specification
Light distribution curve
AC90 to 264V
13
5
Input Voltage
Output Voltage
DC36-48V
Frequency
47-63Hz
Recharge Time
>5 hours
WF2
Insulation Grade
Space Height Ratio
Thread
Leading-in cable diameter
0.0
90.0
12.5
24
40
Anti Corrosion Grade
50
100
150
200
250
300
350
400
450
IP66
12.5
Ingress Protection
I
140
4.5
Mounting hole drawing
G3/4''
8mm -
Dimension
326
Net Weight
326
MH
14mm
75mm
5.5Kg
MH: Metal halide lamp
3. BC9110A, BC9110B
Emergency Explosion proof Light
BC9110A, BC9110B
Emergency Explosion proof Light
Application
Ordering reference
Suitable to be used as emergency lighting in Zone 1 and Zone 2 explosive
gas environment, various indoor and outdoor operation and construction
sites.
80
2,500
35W
80
2,500
Only Emergency
35W
/
80
2,500
70W
40
5,500
70W
40
5,500
70W
MH
BC9110A-J70
Normal illuminate
+ Emergency
/
40
5,500
MH
In the case of power outrage or in any situation where power is
interrupted, this unit will automatically switch to battery backup which
will power the unit for 80 or 40 minutes. (BC9110A-J35:80 minutes,
BC9110A-J70:940minutes)
BC9110B-J70
Only Emergency
MH
BC9110B is only applied for emergency lighting when power outrage,
and on normal condition it is off.
70w Equipped with international famous brand light source and
electrical appliance, more stable performance and gives approximately
20% more light over the other manufacturer's.
Remark: BC9110A: Under normal condition, BC9110A will use normal external power to illuminate. In the case of power outrage or in any situation where
power is interrupted, this unit will automatically switch to battery backup which will power the unit for 80 or 40 minutes.
BC9110B is only applied for emergency lighting when power outrage, and on normal condition it is off.
If emergency switch is needed, please add "-K" behind the model No. for example: BC9110A-J35-K
Drawing of dimension(Dimensions in mm)
The average life span of the light source is more than 10,000 hours.
Therefore it is low maintenance .
460
Two Explosion-proof cavities structure. The wiring cavity is separated
from the main flameproof cavity, enhancing safety.
120
Recharge Time
Explosion proof ballast box
AC220V 50Hz
B1 90
(optional)
B1 30
(optional)
>12 hours
Ingress Protection
IP65
Anti Corrosion Grade
WF2
Insulation Grade
Leading-in cable diameter
2.6
0
Thread
12
Space Height Ratio
I
G3/4''
G3/4 1m
8mm -
10mm
162
Lamp 400 266
M8
170mm
Dimension
Ballast 325 250
120mm
210
Light distribution curve
8.3
Main specification
Input Voltage
300
500
250
Made of aluminium alloy, high strength. The spray coating treatment
ensure the lamp waterproof, anti corrosion.
755
325
2200
Ex Code: Ex de II B T5
Ex de II B T4
Standard: GB3836.1, GB3836.2, GB3836.3
IEC60079-1:2007,MOD
IEC60079-7:2006,MOD
35W
70W
BC9110B-J35
Under normal condition, BC9110A will use normal external power to
illuminate.
Explosion proof ballast box
Emergency
Luminous Flux(lm)
70W
Characteristics of performance
E27
Emergency
Duration (minute)
MH
-40 C
+50 C
Normal illuminate
Wattage (W)
35W
Light Source
Normal illuminate
+ Emergency
Emergency
Wattage (W)
35W
Type
BC9110A-J35
IP65
Model No.
Lamp 5Kg
Net Weight
Ballast 5.5Kg
X (optional)
D (optional)
F (optional)
4. BC9200Series
Maintenance-free Energy-conservation Explosion-proof Light
LED
BC9200Series
Maintenance-free Energy-conservation Explosion-proof Light
Application
Ordering reference
This product is approved for safe use in various explosive and flammable
fields such as petroleum , chemical industry, metallurgy, etc.
Ordering Reference
Light Source
Luminous Flux
(lm)
Wattage(W)
Replace
CFL
BC9200A
-40 C
+50 C
4 3W
1,144
28W
LED
2 3W
572
18W
BC9200C
Characteristics of performance
LED
BC9200B
IP65
LED
348
13W
2
1.5W
Light Source: American CREE LED, save almost 90% on energy than
the incandescent lamp and 60% on energy over the energy saving lamp.
Long Service Life: with the average service life as long as 100,000
hours, maintenance free.
Light distribution curve
Multi-voltage: 90 to 264VAC or 18 to 40V
Feature: LED anti-dazzle lens, making the light more gentle, glare free.
It will not cause weariness to the operators' eyes.
The housing is made of aluminium alloy. With the surface electrostatic
spraying treatment, it is anti corrosion.
Multi-mounting options: Ceiling mounted, wall mounted etc.
The PC transparency has a high light transmissivity, perfect impact
resistance, designed to withstand the harsh industrial applications.
Main specification
Input Voltage
Output Voltage
Frequency
AC(90-264)V or AC/DC(18-40)V
DC14-14.5V
Drawing of dimension(Dimensions in mm)
47-63Hz
Ingress Protection
IP65
Anti Corrosion Grade
WF2
Space Height Ratio
Leading-in cable diameter
130
I
1.2
32
Insulation Grade
170
6mm - 8mm
147
Net Weight
140mm
1.3Kg
150
CFL: Compact fluorescent lamp
140
Dimension
130
Ex Code: Ex de II C T6
Standard: GB3836.1, GB3836.3
IEC60079-7:2007,MOD
5. BC9302A, BC9302B
Emergency Explosion proof Platform Light
BC9302A, BC9302B
Emergency Explosion proof Platform Light
Application
LED
Ordering reference
It is the ideal emergency lighting solution for the Petrochemical
equipment, oil platform, gas station, fuel pump station and some other
explosive environment.
Normal illuminate
Wattage (W)
Emergency
Duration (minute)
Emergency
Luminous Flux(lm)
Replace
25W
120
2,134
35W
15W
40W
120
2,134
35W
15W
60W
120
2,134
35W
15W
/
120
2,134
35W
25W
25W
70
3,300
70W
25W
40W
70
3,300
70W
25W
60W
70
3,300
70W
25W
Light Source
Emergency
Wattage (W)
15W
Type
Model No.
/
70
3,300
70W
BC9302A-L25-L15
IP66
Normal illuminate
+ Emergency
BC9302A-L40-L15
Characteristics of performance
-40 C
BC9302A-L60-L15
With the unique light distribution design, make the light welldistributed. Its beam angel can reach 220 . It efficiently utilize the
light. Have a good performance of illuminance uniformity, glare free,
can avoid eyestrain to the worker.
+50 C
LED
Only Emergency
BC9302B-L15
LED
BC9302A-L25-L25
Normal illuminate
+ Emergency
BC9302A-L40-L25
LED
BC9302A-L60-L25
It adopts American CREE LED as light source, can save 60% or more
on energy than the metal halide lamp.
Equipped world top ranking electrical appliance, ensure the lamp's
performance more stable and efficient.
Ex Code: Ex d II C T6 Gb
Standard: GB3836.1, GB3836.2
IEC60079-1:2007,MOD
The housing is especially designed to dissipate heat. Besides, it uses
the thermal transmission to accelerate the heat conduction which
increase the efficiency and lifespan of the LED, so that to ensure the
100,000 hours LED lifespan.
Only Emergency
BC9302B-L25
LED
Remark: BC9302A: Under normal condition, BC9302A will use normal external power to illuminate (its rated power can be made to 25w 40w 60w). In the
case of power outrage or in any situation where power is interrupted, this unit will automatically switch to battery backup ( lamp wattage can be made to 15w
25w under emergency mode) which will power the unit for 120 or 70 minutes (15w: 120minutes, 25w: 70minutes).
BC9302B is only applied for emergency lighting when power outrage, and on normal condition it is off.
If emergency switch is needed, please add "-K" behind the model No. for example: BC9302A-25-L25-K
Drawing of dimension(Dimensions in mm)
The lamp is made to the highest explosion proof protection grade:
flame proof, so that ensure the lamp can safely used in all kinds of
inflammable and explosive places.
720
370
The lamp can be parallel connected, no need to use the junction box.
The anti corrosion, abrasion proof, power coated cover which is dust
proof, water proof , make the lamp an excellent option for all kinds of
high stress environment.
353
260
Standard
140
Main specification
Output Voltage
AC90 to 264V
(optional)
400
400
240.6
Frequency
47-63Hz
Recharge Time
>5 hours
IP66
Anti Corrosion Grade
X (optional)
WF2
Thread
X
3.5
Mounting hole drawing
2500
Space Height Ratio
I
2300
Insulation Grade
140
12.5
Ingress Protection
G3/4''
G3/4 0.3m
Leading-in cable diameter
8mm -
Dimension
240
Net Weight
5Kg
240
14mm
220mm
520
440
20
40
60
80
100
120
140
160
180
B1 30
DC36-48V
219.5
Light distribution curve
(optional)
249.5
B1 90
Input Voltage
MH
240.6
D (optional)
H (optional)
F (optional)