1. Portable Enraf Terminal
An indispensable tool for configuring,
commissioning, testing and servicing
Enraf’s field instruments
Enraf’s quality line of microprocessor-based field instruments can be easily
configured without opening them. The Portable Enraf Terminal (PET),
a robust and compact device, is the key to externally accessing the Enraf
gauges regardless of weather or operating conditions.
The PET provides an easy means of configuring, commissioning and verifying
instrument settings without taking the gauge out of service. The full
alphanumeric keyboard even allows the operator to type commands with his
gloves on! The LCD display, with four lines of up to 20 alphanumeric characters
per line, makes the PET easy to read under any conditions.
Enraf has simplified the commands to be short, meaningful and easy to
memorize in order to considerable ease the field work. Connection of the PET
to the field instruments is simple. A flexible optical connector easily plugs into
the field instrument’s infra-red communication port. It can also be configured
as an RS-232C interface, between the instrument and a PC.
All settings can now be accomplished from the control room using Enraf
software service utilities. In this way, there is no need to climb the tank.
Its certified intrinsically safe construction allows its use in hazardous
environments, while unauthorized use is prevented by a password access
system.
The PET is one more benefit that Enraf provides to enhance the value of its
field instruments while making your job easier.
Benefits
Cost saving
Intrinsically safe
Promotes personal safety
User friendly
Easy-to-read keyboard
Product sheet
ENRAF
WE THINK TANK
2. Technical specifications
Mechanical
Enclosure : Dust and water proof housing
Dimensions (h x w x d) : 250 mm x 215 mm x 45 mm (10” x 8.5” x 1.8”)
Weight : 2,5 kg (5.5 lb)
Display : LCD, 4 lines each with 20 alphanumeric characters
Keyboard : Full ASCII
Key size : 12 mm x 12 mm (0.5” x 0.5”)
Environmental
Storage temperature : - 55 °C to + 60 °C (- 67 °F to + 140 °F)
Ambient temperature : - 20 °C to + 65 °C (- 4 °F to + 149 °F)
Protection class : IP55 (NEMA 3R)
Safety : Explosion proof
- II 2 G EEx ib IIB T4 according to ATEX
- Class I, II and III, Division 1, Groups B, C and D according to FM, USA
Materials
Housing : Steel enclosure
Finish : Blue epoxy painted
Electrical
Power supply : Rechargeable batteries, 2 pcs 6 V each, 1.2 Ah
Power safe unit : Automatic time out after approximately 15 min
On/off selectable
Battery charger : 120 V, 60 Hz, USA version
230 V, 50 Hz, UK version
230 V, 50 Hz, European version
Charging full load 8 hours
Transmission
Type : - Infra-red via adapter connected to IR port of field instrument
- Enraf field bus, Bi-Phase Mark (BPM) communication via adapter
connected to field instrument terminals
- RS-232C connected to PC with Enraf software service utilities
Baud rate : Selectable
- IR 300 baud, 1200 baud or 2400 baud
- EN bus 1200 baud, 2400 baud or 4800 baud
- RS-232C 1200 baud, 2400 baud or 4800 baud
Options
Interface : RS-232C interface (1847.811)
The PET comes complete with
Carrying case
Battery charger For type to be selected see Identification code
IR-adaptor Part number 0847.380
EN bus adapter Part number 1847.812
3. Identification code
Pos 1 Application
U General purpose
Pos 2 Option not used
*
Pos 3 Option not used
*
Pos 4 Option not used
*
Pos 5, 6, 7 Instrument designation
8 4 7 Portable Enraf Terminal
Pos 8 Battery charger
A 230 V, 50 Hz, Europe
C 120 V, 60 Hz, USA
K 230 V, 50 Hz, UK
Pos 9 Safety approvals
A ATEX Europe
F FM USA
For other approvals please contact your nearest Enraf office
U * * * 8 4 7 A A Typical identification code