Husk based power plant 6 t 32 kg fbc with single stage turbine for finance,...
SW-102-AAD - Layout with both skids
1. 180
231
2300
2069
2300
231
2069
HIGH LEVEL
STEAM OUT
GROUND FLOOR
HOT WATER RETURN 1" DOM TUBING
SKID 1 LOW TEMPERATURE 50/55
SKID 1 LOW TEMPERATURE 50/55
HIGH LEVEL
CUSTOMER
HIGH LEVEL
C
EQUIPMENT
WATER MAKE-UP
0.37kW PUMP
HOT WATER TANK
STEAM IN
JACKETED PIPE : ID = NW50
ANCHOR TYPE MIXER c/w teflon wiper blades
HOT WATER TO PUMP
PADDLE MIXER
CUSTOMER
SKID 2 HIGH TEMPERATURE 70/75
0.37kW PUMP
GROUND FLOOR
2.2kW PUMP
WATER MAKE-UP
C
WATER MAKE-UP
OD =
STEAM IN
GROUND FLOOR
2.2kW PUMP
WATER MAKE-UP
NOTE - SEE DRAWING W0890_02 RevB FOR P&ID DIAGRAM
GATE/TEFLON WIPER MIXER
PRODUCT INTO JACKETED PIPE @ 75
PRODUCT TANK
STEAM OUT
1.1kW 75RPM
SKID 2 HIGH TEMPERATURE 70/75
PRODUCT TANK
TURBINE TYPE MIXER c/w 2 blade impellers
1.5kW 35RPM
C
EQUIPMENT
HOT WATER TO PUMP
HOT WATER TANK
C
65 DOM TUBING
STEAM IN
745
2500
1200
600
2500
1702
2231250
1100
3181250
1100
800 800
DATE :
TITLE:
Tel: +27 21 905 5324 Fax: +27 21 905 1771
JOB/ENQ. No :CHECKED BY:
REV.APPROVED BY :
DRAWN BY :
DRG No.
IF IN DOUBT - PLEASE ASK!
-SW-102-AAD
J0744
TOLERANCES (U.O.S)
ALL DIMENSIONS IN MILLIMETERS (mm)
UNLESS OTHERWISE SPECIFIED
JELLY AND FLAN PLANT LAYOUT
INNODIS
CUSTOMER:
24-11-2015
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY
OF IMVUSA STAINLESS AND ANY REPRODUCTION AS A WHOLE OR IN PART
WITHOUT WRITTEN PERMISSION FROM IMVUSA STAINLESS IS PROHIBITED
SCALE:
1:50
LESTER
PO Box 156 Blackheath 7581 cnr Electron & Wimbeldon Rd Blackheath 7580
THIS DRAWING IS THE PROPERTY OF IMVUSA STAINLESS