This document contains plans and notes for the renovation and addition of a property on Rosemead Blvd in San Gabriel, CA. It includes general notes specifying requirements for smoke detectors, ventilation fans, shower dimensions, and energy conservation standards. Electrical notes require GFCI outlets in certain locations. Floor plans at a scale of 1/4"=1'-0" are provided for the 1st, 2nd, and 3rd floors. A window schedule, door schedule, and fixture schedule are included, along with sections and elevations.
As the senior public relations and marketing director for Brunello Cucunelli USA in NYC, Giorgiana Magnolfi drives the corporate strategy for external communications and sales. Through this work, Giorgiana Magnolfi has been provided the opportunity to collaborate with many charitable organizations, including the Camino Health Center Auxiliary.
As the senior public relations and marketing director for Brunello Cucunelli USA in NYC, Giorgiana Magnolfi drives the corporate strategy for external communications and sales. Through this work, Giorgiana Magnolfi has been provided the opportunity to collaborate with many charitable organizations, including the Camino Health Center Auxiliary.
1. A-2
DRAWN BY: ALF
DATE: DEC.16.14
NEWRENOVATIONANDADDITION
Rosemead Blvd, San Gabriel, CA
GENERAL NOTES
SMOKE DETECTOR TO BE WIRED TO ELECTRONIC
SYSTEM. MUST HAVE BATTERY BACK-UP.
INTERCONNECTED.
PROVIDE FAN WITH FIVE AIR CHANGES PER HOUR. MUST
BE VENTED TO THE OUTSIDE. 50 CMF MI
SHOWERS SHALL BE FINISHED 70" ABOVE DRAIN WITH
S
F
ENERGY CONSERVATION STANDARDS
1. A NIGHT THERMOSTAT SHALL BE INSTALLED. 40
LUMENS/WATTS EFFICIENCY FIXTURES SHALL BE
PROVIDED FOR GENERAL LIGHTING IN KITCHENS AND
BATHROOMS. (FLUORESCENT TYPE)
2. A R-12 EXTERIOR BLANKET SHALL BE PROVIDED FOR
WATER HEATER AND SOLAR TANKS. R-3 INSULATION
ELECTRICAL GENERAL NOTES
1. GROUND CIRCUIT INTERRUPTER (GF1)
OUTLETS SHALL BE PROVIDED IN BATHROOMS,
GARAGES, BASEMENTS, CRAWL SPACE,
OUTSIDE AND WITHIN 6 FEET 0F KITCHEN SINK.
2. ELECTRICAL WIRING SHALL BE COPPER, NO
ALUMINUM WIRING IS ALLOWED UNLESS
CONTINUOUS SPECIAL INSPECTION IS
1st FLOOR PLAN
SCALE : 1/4" = 1'-0"
2nd FLOOR PLAN
SCALE : 1/4" = 1'-0"
3rd FLOOR PLAN
SCALE : 1/4" = 1'-0"
BEDROOM
KITCHENLIVING ROOM DINING ROOM BEDROOM
HIS/HERS
BEDROOM
DN
UP
UP
2ND
FLOOR
7'-11" 5'-6" 5'-0" 14'-0"
13'-5" 19'-0"
20'-0"3'-0"
10'-0"8'-6"2'-7"6'-7"
18'-0"
8'-6"
7'-63
4"
13'-0"
18'-6"9'-2"
27'-8"
32'-5"
2'-6"
13'-8"
8'-6"
4'-6"4'-4"
5'-6"3'-0"5'-6"
2'-2"3'-4"
19'-2"
9'-0"11'-5"
23'-0"
6'-3"
32'-5"
8'-9"10'-5"7'-0"
3'-0"11'-8"
6'-0"5'-8"3'-4"5'-0"
8'-4"
23'-0"
7'-2"11'-6"
9'-2"2'-4"5'-10"7'-11"
13'-9"
32'-5"
7'-63
4"
7'-63
4"
13'-0"
7'-0"
13'-8"
6'-8"
19'-2"
2'-2"3'-4"
5'-6"
8'-6"
3'-0"5'-6"
2'-4" 3'-0" 13'-2"
WINDOW SCHEDULE
WINDOW WINDOW SIZE
(WIDTH x HEIGHT) REMARKSTEMP. MATERIALNUMBER AMOUNT
W01 VYNIL
TYPE
1 5
W02
W03
-----
6
ALL WINDOWS TO BE DBL GLAZED
2'-0" X 4'-0"
VYNIL
VYNIL5'-0" X 4'-0"
2
SLIDER. PROVIDE EGRESS.
U - FACTOR = 0.36 SHGC = .24 PER TITLE 24 ENERGY
D01
D04
D07
D07
D07
D07
D07
D02
HUNG
W01
13'-0"
W01 W01
W01
2'-0" X 1'-0"
W01
D03
-----
W03 W03 W03
W03
TEMPERED. AWNINGTEMP.
STANDARDSTANDARD
1
2
3
4
5
6
7
8
9
10
11
12
13 14 15
1
2
3
4
5
6
7
8
9
10
11
4
5
6
7
8
9
10
11
12 13 14
15
16
17
18
D07
A
A-4
B
A-4
C
A-4
D
A-4
OPEN TO
ABOVE
D07
D06 D05
D07
D07
D08
D09
W02 W03
W04
W02
W05
OPEN TO
ABOVE
OPEN TO
BELOW
OPEN TO
BELOW
24 x 36
SKYLIGHT
BEAM
ABOVE
S
S
S
SS
C
A-4
D
A-4
A
A-4
B
A-4
A
A-4
B
A-4
C
A-4
D
A-4
C
A-4
D
A-4
A
A-4
B
A-4
A
A-4
B
A-4
C
A-4
D
A-4
C
A-4
D
A-4
A
A-4
B
A-4
FOYER 2-CAR GARAGE
3D
F (GFI)
3
(GFI)
S
DN
13 14
(GFI)
F
(GFI)
F
(GFI)(GFI)
3
33
33
3D
3
(GFI)
S S
S
(GFI)
F
33
3
LATTER
ROOF
ACCESS
2'-6"
2'-9"
2'-8"
2'-9"
2'-8"
D08
2'-4"
2'-7"
W03
LUIS MA
SC
ENVIRO
1161 MA
LOS ANG
luism@