SlideShare a Scribd company logo
1 of 592
Download to read offline
2014R.STAHLcondensedcatalogue
ID 223602
2014-02/en-00 · Printed in Germany
R.STAHL
Am Bahnhof 30
74638 WALDENBURG · GERMANY
T +49 7942 943-0
F +49 7942 943-4333
info@stahl.de
www.stahl.de
condensed catalogue 2014
Products for explosive gas atmospheres and areas with combustible dust
Explosion protected electrical equipment
Systems and components for automation
Explosion protected light fittings and
emergency lighting systems
2013-09-10·KP00·III·en
Explosion Protection by R. STAHL - General Catalogue
Sales
R. STAHL
Am Bahnhof 30 · 74638 Waldenburg (Württ.) E
T +49 (0) 79 42 / 943 - 0 · F +49 (0) 79 42 / 943 - 4333
sales_ex@stahl.de · www.stahl.de
R. STAHL · www.stahl.de
Please find your contact person under the sales organisation, see page 588
The newest CD
with the R. STAHL
catalogue can be
obtained from your
R. STAHL partner.
U2_KP_2014_en.fm Seite 1 Mittwoch, 15. Januar 2014 4:22 16
12013-09-10·KP00·III·en Contents
Condensed Catalogue 2014
valid as of January 2014
Seite
0 General Information 2
Terms of Sale and Delivery | Pictograms | WebCode
A2 Safety Barriers 4
General | Single-Channel-Safety Barriers | Dual-Channel-Safety Barriers
A3 Isolators 12
Overview | Power Supply | Transmitter | Isolating Repeater | Switching Repeater
Relay Module | Binary Output | HART-Multiplexer | System Components | pac-Bus | pac Carrier
A4 Remote I/O 74
General Information | CPU & Power Modules | BusRail | Temperature Input Modules
Input/Output Modules for Analog Signals | Input/Output Modules for Digital Signals
A5 Fieldbus Technology 118
General Information | Power Supply and Diagnosis | Field Device Coupler | System Components and Accessories
A6 Wireless 140
General Information | WLAN Access Point | Localisation System | WirelessHART Gateway
A7 Operating and Monitoring Systems 152
System Description | Remote HMI | Open HMI | Operator Interfaces Eagle
Operator Interfaces Falcon | Enclosures
A8 Camera and Video Systems 234
Camera Systems for all Areas | Cameras | Video Software
E2 Lighting 254
Compact Light Fittings | Light Fittings for Flourescent Lamps | Tubular Light Fittings | Emergency Light Fittings
LED Cluster Lighting | Pendant Light Fittings | Bulkhead Light Fittings | Floodlights |Portable Lamps | Hand Lamps
E3 Installation Equipment 326
Installation Switches | Junction Boxes | Terminal Boxes | Connection Technology for Data Networks | Plug Connectors
Plugs and Sockets | Couplers | Coupler Sockets | Socket Outlet Assemblies | Maintenance Socket Isolators | Cable Reel
E4 Control Devices 378
Position Switches | Radio Position Switches | Control Equipment for Panel Mounting | Control Device System
Grounding Systems and Grounding Monitoring Devices | Measuring and Monitoring Equipment for Panel Mounting
E5 Signalling Devices 452
Visual Signalling Devices | Audible and Visual Signalling Devices | Audible Signalling Devices | Operator Panels
E6 Components for Heating Systems 496
Junction Boxes for Heat Tracing | Temperature Controller and Limiter | Thermostats | Accessories
E7 Load Disconnect Switches and Motor Starters 514
Safety Switches | Load and Motor Switchgear | Motor Protection Circuit-Breakers | Standard Motor Starters
Direct On-Line Motor Starters | Star-Delta Starter Combinations | Reversing Starter Combinations
E8 Applications Low Voltage Systems 532
Power Distribution | Lighting and Heating Panels | Machine Controls | Battery Boxes
UPS Uninterrupted Power Supply | Pressurized Apparatus
E9 Components for System Solutions 544
Ex d Technology | Ex e Technology | Components for Use in Ex d and Ex e Enclosures
E10 Installation Equipment and Accessories 548
Cable Glands | Cable Glands with Strain Relief | Cable Glands in Brass
Breathing Glands | Stopping Plugs | Accessories
Type Index - Sales Organisation / International 584
Type Index | Addresses
Inhaltsverzeichnis_2014_KP00_III_en.fm Seite 1 Mittwoch, 15. Januar 2014 4:44 16
0
2 2013-09-10·KP00·III·en
Condensed Catalogue 2014
Conditions of Sales and Delivery, Pictograms and WebCode
R. STAHL Schaltgeräte GmbH
Conditions of Sales and Delivery
The list on hand will be valid as of 2014-01-01.
All lists published up to now, including the technical
specifications and the conditions of sale and delivery,
will then be no longer valid and will be replaced by the
list on hand.
All deliveries and services are based on our
“General Terms and Conditions of Delivery“.
They become an integral part of the contract with each order
and can be viewed under the link:
www.stahl.de / DOWNLOADS
Changes of technical data, dimensions, weights, design and
availability are reserved.
The items in this list form a focus of our program of delivery.
This “Condensed Catalogue“ will be run with a higher
stockpiling of devices and component parts.
With our “Condensed Catalogue“ we want to make your
scheduling and warehousing easier.
If you will favour these devices during construction and project
planning you will secure yourself particularly convenient
delivery times.
You may find the complete delivery program in our
general catalogue and up-to-date in our online-catalogue
www.stahl.de.
Product Segments PS
In the present “Condensed Catalogue“ you will find an
associated product segment with every item number.
This allows a computerized classification of defined
product segments and delivery conditions.
Mark-up for small-volume purchases
For purchase orders with a net order value < 100 Euro we will
charge a mark-up for small-volume purchases of 25 Euro net.
Cancellation
We will charge a processing fee of 50 Euro net for the
cancellation of an order. With special productions according to
the orders the cancellation costs will depend on the production
stage.
Repurchase
Repurchases are only possible for unopened regular stock
on hand, within 6 months after delivery and only with prior
consultation. If the goods have been returned freight prepaid
and after the quality of the returned goods has been accepted
we will credit 70% of the product invoice value.
Pictograms Application of the Pictograms
Ex Symbol
for all devices in explosion-protected design
Offshore
for all devices that are suitable for offshore applications. When the materials are
selected special importance is put on the harsh conditions of seawater atmosphere.
Shipping
for all devices with ship approval
Low temperature
for all devices that may be used in temperatures below -20 °C
High temperature
for all devices that may be used in temperatures higher than +40 °C
Lieferbedingungen_2014_KP00_III_en.fm Seite 2 Mittwoch, 15. Januar 2014 4:52 16
0
32013-09-10·KP00·III·en R. STAHL Schaltgeräte GmbH
Condensed Catalogue 2014
Conditions of Sales and Delivery, Pictograms and WebCode
WebCode Description
By entering the WebCode on our homepage www.stahl.de you will be led directly
to the respective documents.WebCode XXXXXXX
WebCode Example: Installation Switch Series 8030/51
WebCode A8030
Lieferbedingungen_2014_KP00_III_en.fm Seite 3 Mittwoch, 15. Januar 2014 4:52 16
4 2013-09-10·KP00·III·enSafety Barrieres
Safety Barriers
Kapitel_A2_KP00_en.book Seite 4 Dienstag, 7. Januar 2014 7:52 07
A2
52013-09-10·KP00·III·en Safety Barriers
Contents
Safety Barriers
Single-Channel Safety Barriers INTRINSPAK 9001 6
Dual-Channel Safety Barriers INTRINSPAK 9002 8
Safety Barriers with Electronic Current Limitation INTRINSPAK 9004 10
You will find further information on the Internet www.stahl.de
General Information
Engineering
Application Examples
Accessories and Spare Parts
Kapitel_A2_KP00_en.book Seite 5 Dienstag, 7. Januar 2014 7:52 07
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Safety Barriers
Series 9001 / 9002 / 9004
6 Safety Barriers 2013-09-10·KP00·III·en
Series 9001 / 9002 / 9004 A2
10064E00
9001: WebCode 9001A
> Complete product range for all standard
applications
> Flexible and space saving - single and
dual channel versions on 12 mm only
> Time-saving installation thanks to
simultaneous
– snapping onto the rail and
– connecting to PE and earth
> Reduced inventory due to uniform
exchangeable fuse
*) Restrictions see table explosion protection
ATEX / IECEX NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
9001, 9002:
Ex i interfaces
x x x x x x 9001, 9002:
Ex i interfaces
9001, 9002:
Ex i interfaces
x x x x x x
9004:
Ex i interfaces
x x x x 9004:
Ex i interfaces
9004:
Ex i interfaces
x x x
Installation in x x Installation in x x Installation in x x*) x*)
Technical Data
Version 9001 9002 9004
Explosion protection
Global (IECEx)
Gas and dust IECEx PTB 09.0001X IECEx PTB 08.0057X IECEx PTB 12.0003X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Ex nA [ib Gb] IIC T4 Gc
Ex nA [ib Gb] IIB T4 Gc
[Ex ib Db] IIIC
Europe (ATEX)
Gas and dust PTB 01 ATEX 2088 X PTB 01 ATEX 2053 X PTB 02 ATEX 2008
E II 3 (1) G Ex nA [ia Ga]
IIC/IIB T4 Gc
E II (1) D [Ex ia Da] IIIC
E II 3 (1) G Ex nA [ia Ga]
IIC/IIB T4 Gc
E II (1) D [Ex ia Da] IIIC
E II (2) GD [EEx ib] IIB/IIC
E II 3 G EEx nA II T4
(Installation in Zone 2)
Certifications and certificates
Certificates IECEx, ATEX, Canada (CSA),
Kazakhstan
(operating licence),
Russia (GOST R),
Serbia (SRPS), Ukraine (TR),
Belarus (operating
authorisation)
IECEx, ATEX, Canada (CSA),
Kazakhstan
(operating licence),
Russia (GOST R),
Serbia (SRPS), Ukraine (TR),
USA (FM, UL), Belarus
(operating authorisation)
IECEx, ATEX, Canada (CSA),
Kazakhstan
(operating authorisation),
Russia (GOST R),
Serbia (SRPS), Ukraine (TR),
Belarus (operating
authorisation)
Further parameters
Installation in Zone 2, Division 2 and in safe area
Further information see respective certificate and operating instructions
Enclosure material Polyamide 6 GF
Degree of protection
Connection type 4 cage terminals, each maximum 1.5 mm2 flexible / solid
2 PA-terminals, each maximum 4 mm2 flexible / solid
Ambient temperature
Ambient temperature -20 ... +60 °C
Storage -20 ... +75 °C
Dimensions 12 x 104 x 70 mm
Weight approx. 0.115 kg
according to IEC 60529
terminal enclosure:
housing:
IP20
IP40
9002: WebCode 9002A
9004: WebCode 9004A
9001_9002_9004_SafetyBarriers_KP00_III_en.fm Seite 6 Montag, 13. Januar 2014 10:01 10
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
72013-09-10·KP00·III·en Safety Barriers
Safety Barriers
Series 9001 / 9002 / 9004
Selection table
UN Rmax Safety data Schematic Order number Art. no. PS
Uo Io Po
V Ω V mA mW
Single-Channel Safety Barriers for Negative Polarity Series 9001/00
6 32 8.6 390 839 Pic. A 9001/00-086-390-101 158434 20
24 375 28 85 595 Pic. A 9001/00-280-085-101 158344 20
319 28 100 700 Pic. A 9001/00-280-100-101 158356 20
Single-Channel Safety Barriers for Positive Polarity Series 9001/01
6 27 8.3 442 917.2 Pic. B 9001/01-083-442-101 158338 20
218 8.6 50 107.5 Pic. B 9001/01-086-050-101 158379 20
73 8.6 150 322.5 Pic. B 9001/01-086-150-101 158418 20
32 8.6 390 839 Pic. B 9001/01-086-390-101 158439 20
8 106 12.6 150 473 Pic. B 9001/01-126-150-101 158502 20
12 135 15.8 150 593 Pic. B 9001/01-158-150-101 158535 20
53 15.8 390 1541 Pic. E 9001/01-158-390-101 158509 20
262 16.8 75 315 Pic. B 9001/01-168-075-101 158568 20
16 241 19.9 100 498 Pic. B 9001/01-199-100-101 158632 20
168 19.9 150 746 Pic. B 9001/01-199-150-101 158638 20
66 19.9 390 1940 Pic. E 9001/01-199-390-101 158519 20
20 ... 35 505 25.2 57 359 Pic. C 9001/01-252-057-141 158689 20
505 25.2 60 378 Pic. D 9001/01-252-060-141 158693 20
268 25.2 100 630 Pic. M 9001/01-252-100-141 158697 20
24 666 28 50 350 Pic. B 9001/01-280-050-101 158665 20
375 28 85 595 Pic. B 9001/01-280-085-101 158351 20
319 28 100 700 Pic. B 9001/01-280-100-101 158365 20
294 28 110 770 Pic. B 9001/01-280-110-101 158380 20
198 28 165 1155 Pic. B 9001/01-280-165-101 158392 20
124 28 280 1960 Pic. E 9001/01-280-280-101 158722 20
Single-Channel Safety Barriers for Alternating Polarity Series 9001/02
0.7 134 1.6 15 6 Pic. F 9001/02-016-015-101 158669 20
43 1.6 50 20 Pic. F 9001/02-016-050-101 158673 20
20 1.6 150 60 Pic. F 9001/02-016-150-101 158681 20
20.1 1.6 150 60 Pic. F 9001/02-016-150-111 158685 20
6 354 9.3 30 69.8 Pic. F 9001/02-093-030-101 158743 20
79 9.3 150 348.8 Pic. F 9001/02-093-150-101 158753 20
36 9.3 390 906.8 Pic. F 9001/02-093-390-101 158755 20
Single-Channel Diode Return Barriers for Positive Polarity Series 9001/03
16 – – 19.9 0 0 Pic. G 9001/03-199-000-101 158475 20
24 – – 28 0 0 Pic. G 9001/03-280-000-101 158486 20
Single-Channel Safety Barriers for Transmitter Series 9001/51
20 ... 35 – – 28 110 770 Pic. K 9001/51-280-110-141 158530 20
– – 28 91 637 Pic. L 9001/51-280-091-141 158524 20
Kapitel_A2_KP00_en.book Seite 7 Dienstag, 7. Januar 2014 7:52 07
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
8 2013-09-10·KP00·III·en
Safety Barriers
Series 9001 / 9002 / 9004
Safety Barriers
Schematic for Single-Channel Safety Barriers Series 9001
09405E00 09406E00 09407E00
Picture A Picture B Picture C
09408E00 09409E00 09410E00
Picture D Picture E Picture F
09411E00 09415E00 09416E00
Picture G Picture K Picture L
09417E00
Picture M
+ UN + UN Ex i
Selection table
Channel UN Rmin Rmax Safety data Schematic Order number Art. no. PS
Uo Io Po
V Ω Ω V mA mW
Dual-Channel Safety Barriers Polarity: - / - Series 9002/00
1
2
1+2
22.5
17.5
- -
321
416
- -
358
463
- -
26
20
26
87
51
138
540
245
785
Pic. C 9002/00-260-138-001 158867 20
Dual-Channel Safety Barriers Polarity: + / - Series 9002/10
1
2
1+2
6
6
- -
490
490
- -
543
543
- -
9.33
9.33
18.7
20
20
20
50
50
90
Pic. A 9002/10-187-020-001 158937 20
1
2
1+2
6
6
- -
42
42
- -
49
49
- -
9.33
9.33
18.7
270
270
270
630
630
1260
Pic. A 9002/10-187-270-001 158933 20
Kapitel_A2_KP00_en.book Seite 8 Dienstag, 7. Januar 2014 7:52 07
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
92013-09-10·KP00·III·en Safety Barriers
Safety Barriers
Series 9001 / 9002 / 9004
Dual-Channel Safety Barriers Polarity: + / + Series 9002/11
1
2
1+2
16
16
- -
1423
1423
- -
1576
1576
- -
19.9
19.9
19.9
15
15
30
75
75
150
Pic. B 9002/11-199-030-001 158929 20
1
2
1+2
22.5
17.5
- -
321
416
- -
358
463
- -
26
20
26
87
51
138
570
260
850
Pic. B 9002/11-260-138-001 158870 20
1
2
1+2
25
25
- -
321
321
- -
358
358
- -
28
28
28
93
93
186
650
650
1300
Pic. B 9002/11-280-186-001 158848 20
Dual-Channel Safety Barriers Safety Barrier Polarity: + / Signal Barrier Polarity: + Series 9002/13
1
2
1+2
16
16
- -
95
- -
- -
108
- -
- -
19.9
19.9
19.9
222
3
225
1100
15
1120
Pic. F 9002/13-199-225-001 158921 20
1
2
1+2
20 - 35
22
- -
216
- -
- -
243
- -
- -
25.2
25.2
25.2
118
0
121
740
20
760
Pic. N 9002/13-252-121-041 158830 20
1
2
1+2
24
24
- -
321
- -
- -
358
- -
- -
28
28
28
90
3
93
630
21
651
Pic. F 9002/13-280-093-001 158852 20
1
2
1+2
20 - 35
26
- -
292
- -
- -
327
- -
- -
28
28
28
97
0
100
679
21
700
Pic. G 9002/13-280-100-041 158818 20
1
2
1+2
24
24
- -
269
- -
- -
290
- -
- -
28
28
28
107
3
110
749
21
770
Pic. F 9002/13-280-110-001 158857 20
Dual-Channel Safety Barriers Polarity: ~ / ~ Series 9002/22
1
2
1+2
0.7
0.7
1.4
19.9
19.9
- -
20.1
20.1
- -
1.6
1.6
3.2
150
150
300
60
60
120
Pic. J 9002/22-032-300-111 158954 20
1
2
1+2
9
9
18
158
158
- -
177
177
- -
12
12
24
80
80
160
240
240
480
Pic. M 9002/22-240-160-001 158948 20
Dual-Channel Safety Barriers Signal Barrier Polarity: + / Signal Barrier Polarity: + Series 9002/33
1
2
1+2
25.5
25.5
- -
0
- -
- -
0
- -
- -
28
28
28
0
0
0
0
0
0
Pic. I 9002/33-280-000-001 158913 20
Dual-Channel Safety Barriers Star Barrier / Star Barrier Series 9002/77
1
2
1+2 6
492
492
- -
545
545
- -
9.3
9.3
9.3
20
20
40
50
50
90
Pic. K 9002/77-093-040-001 158905 20
1
2
1+2 6
71
71
- -
82.1
82.1
- -
9.3
9.3
9.3
150
150
300
350
350
700
Pic. K 9002/77-093-300-001 158897 20
1
2
1+2 12
111
111
- -
126
126
- -
15
15
15
150
150
300
560
560
1130
Pic. K 9002/77-150-300-001 158889 20
1
2
1+2 24
657
657
- -
730
730
- -
28
28
28
47
47
94
330
330
660
Pic. K 9002/77-280-094-001 158877 20
Selection table
Channel UN Rmin Rmax Safety data Schematic Order number Art. no. PS
Uo Io Po
V Ω Ω V mA mW
Kapitel_A2_KP00_en.book Seite 9 Dienstag, 7. Januar 2014 7:52 07
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
10 2013-09-10·KP00·III·en
Safety Barriers
Series 9001 / 9002 / 9004
Safety Barriers
Schematic for Dual-Channel Safety Barriers Series 9002
09418E00 09419E00 09420E00
Picture A Picture B Picture C
09422E00 09423E00 09424E00
Picture E Picture F Picture G
09425E00 09426E00 09427E00
Picture H Picture I Picture J
09428E00 09430E00 11030E00
Picture K Picture M Picture N
Selection table
UN Rmax Safety data Schematic Order number Art. no. PS
Uo Io Po
V Ω V mA mW
Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity Series 9004/01
12 30 16.8 50 840 Pic. A 9004/01-168-050-001 159060 20
24 56 28 45 1260 Pic. A 9004/01-280-045-001 159082 20
26 73 31.5 25 787.5 Pic. A 9004/01-315-025-001 159086 20
Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity with Voltage Limitation Series 9004/51
23 ... 27 – – 20.6 50 1030 Pic. B 9004/51-206-050-001 159090 20
Schematic
Single-Channel Safety Barriers with Electronic Current Limitation, Polarity +
10013E00 10014E00
Picture A Picture B
Kapitel_A2_KP00_en.book Seite 10 Dienstag, 7. Januar 2014 7:52 07
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
112013-09-10·KP00·III·en Safety Barriers
Safety Barriers
Series 9001 / 9002 / 9004
Kapitel_A2_KP00_en.book Seite 11 Dienstag, 7. Januar 2014 7:52 07
12 2013-09-10·KP00·III·enIsolators
Isolators
Isolators
Overview of the System Components ISpac 14
General ISpac 15
Applications ISpac 16
Ex i Isolators
Power Supply
Ex i Power Supply ISpac 9143 18
Transmitter
Frequency Transmitter ISpac 9146 20
Vibration Transducer Supply Unit ISpac 9147 22
Transmitter Supply Unit ISpac 9160 24
Transmitter Supply Unit with Limit Value ISpac 9162 26
Temperature Transmitter ISpac 9182 50
Isolating Repeater
Isolating Repeater HART Input ISpac 9163 28
mA-Isolating Repeater ISpac 9164 30
Isolating Repeater ISpac 9165 32
Isolating Repeater Loop Powered ISpac 9167 34
Resistance Isolator ISpac 9180 48
Kapitel_A3_KP00_en.book Seite 12 Dienstag, 7. Januar 2014 8:03 08
A3
132013-09-10·KP00·III·en Isolators
Contents
Ex i Isolators
Isolating Repeater
Fieldbus Isolating Repeater ISpac 9185 52
Fibre Optics Fieldbus Isolating Repeater ISpac 9186 54
Switching Repeater
Switching Repeater ISpac 9170 36
Relay Module
I.S. Relay Module ISpac 9172 38
Electronic Relay ISpac 9174 40
Binary Output
Binary Output ISpac 9175 42
Binary Output with Line Fault Transparency ISpac 9175 44
Binary Output without Power Supply ISpac 9176 46
Non - Ex i Isolators
Transmitter
Transmitter Supply Unit ISpac 9160 66
Transmitter Supply Unit with Limit Value ISpac 9162 67
mA-Isolating Repeater ISpac 9164 68
Isolating Repeater ISpac 9165 69
Isolating Repeater Loop Powered ISpac 9167 70
Relay Module ISpac 9172 71
Temperature Transmitter ISpac 9182 73
System Components
Supply Module ISpac 9193 58
HART Termination Board ISpac 9196 64
HART-Multiplexer ISpac 9192 56
pac-Bus ISpac 9194 60
pac-Carrier ISpac 9195 62
You will find further information on the Internet www.stahl.de
Engineering ISpac
Kapitel_A3_KP00_en.book Seite 13 Dienstag, 7. Januar 2014 8:03 08
A3
14 2013-09-10·KP00·III·en
General
Isolators
Overview of the System Components
15801E00
Control Level
Asset
PLC / DCS PLC / DCS
Zone 2 / Division 2
Control Level
Zone 1 / Division 1
Control Level
Classic/HART
meld devices
Classic/HART
meld devices
Management
Level
Field Circuit Non-Ex i
Field Circuit Ex i
Kapitel_A3_KP00_en.book Seite 14 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
General
15Isolators2013-09-10·KP00·III·en
A3
11748E00
WebCode ISpacA
> Versions Ex i and non-Ex i
> All functions with 2 channels per module
> Galvanic isolation between inputs, outputs and
power supply
> Modules for DIN-rail installation or comfortable
system integration via pac-Carrier
> Detachable terminals available in screw terminal
and spring clamp terminal versions
> Extended temperature range -20 … +70 °C
> Installation possible in Zone 2 resp. Div. 2
> Most isolator versions can be used for applications
according to „functional safety“ SIL (IEC 61508)
> Customer specific engineering by
R. Stahl’s competence center
> macros for easier planning and
engineering available
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x x x Ex i
interface
x x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Technical Data
Mounting type on DIN-rail (NS35/15, NS35/7.5) or in pac-Carrier
Versions - Screw terminals (standard)
- Spring clamp terminals
Removable, for wire cross-section 0.2 ... 2.5 mm2 or 2 x 1.5 mm2 flexible with or
without splay protection or single-wire
Degree of protection
Enclosure IP30
Terminals IP20
Ambient conditions
Ambient temperature
Single device -20 ... +70 °C
Group assembly -20 ... +60 °C
The installation conditions affect the ambient temperature.
Observe operating instructions.
Storage temperature -40 ... +80 °C
Galvanic isolation Between inputs, outputs and power supply
Voltage range 18 ... 31.2 V DC / 96 ... 253 V AC (only 9170)
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs),
Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Installation in Zone 2, Div. 2 and in the safe area
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
06812E00
122mm/4.80"
X
99 mm / 3.90 " Y
114,5mm/4.51"
Dim. X
Screw terminals 108 mm / 4.25 in
Spring clamp terminals 128 mm / 5.04 in
Dim. Y
Series 9143, 9185, 9192 35.2 mm / 1.39 in
Series 9146, 9147, 9160, 9162,
9163, 9165, 9167, 9170, 9172,
9175, 9176, 9180, 9182, 9193
17.6 mm / 0.69 in
Kapitel_A3_KP00_en.book Seite 15 Dienstag, 7. Januar 2014 8:03 08
A3
16 2013-09-10·KP00·III·en
ISpac
Isolators
Application of isolators
Symbol Application ISpac Type Ex i
Signal circuit
Non Ex i
Signal circuit
06861E00
2-, 3-, 4-wire transmitters and
current sources
9160
9162 (with limit value)
Page 24
Page 26
Page 66
Page 67
06329E00
2-wire HART transmitter 9160
9162 (with limit value)
Page 24
Page 26
Page 66
Page 67
07649E00
4-wire HART transmitter 9163
9164
Page 28
Page 30 Page 68
06321E00
I/P converter, HART control valve 9165
9167
Page 32
Page 34
Page 69
Page 70
06331E00
Resistance thermometers /
Resistance temperature detectors
(RTD)
9182
9180
Page 50
Page 48
Page 72
06332E00
Thermocouple 9182 Page 50 Page 72
06333E00
Contact, optocouple output 9170
9172
Page 36
Page 38
06334E00
NAMUR proximity switch 9170 Page 36
06326E00
Speed control,
Flow measurement
9146 Page 20
06324E00
Solenoid valve,
LED indicating lamp, horn
9175
9176
9172
9174
Page 42
Page 46
Page 38
Page 40
Page 71
06327E00
Fire & gas detectors 9167 Page 34 Page 70
Kapitel_A3_KP00_en.book Seite 16 Dienstag, 7. Januar 2014 8:03 08
A3
172013-09-10·KP00·III·en Isolators
ISpac
06317E00
Alarm contact 9146
9162
9182
Page 20
Page 26
Page 50
Page 67
Page 72
06330E00
HART Multiplexer 9192
9196
Page 56
Page 64
06328E00
Modbus, Profibus DP,
ServiceBus R.STAHL
9185
9186
Page 52
Page 54
06318E00
Power supply of
intrinsically safe users
9143 Page 18
06892E00
Vibration sensor 9147 Page 22
15280E00
Voltage source 9163 Page 28
Application of isolators
Symbol Application ISpac Type Ex i
Signal circuit
Non Ex i
Signal circuit
HART
Ex i
V
Kapitel_A3_KP00_en.book Seite 17 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Ex i Power Supply
Field Circuit Ex i
Series 9143
18 Isolators 2013-09-10·KP00·III·en
Series 9143 A3
07673E00
WebCode 9143A
> For intrinsically safe power supply of
3- or 4-wire transmittters and controllers
> Intrinsically safe output [Ex ib] IIC/IIB
> Stable output voltage
> Galvanic isolation between output and
power supply
> Power supply 24 V AC / DC or 85 ... 230 V AC
> Compact design
*) Restrictions see table explosion protection
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x
Installation in x*) x*)
Selection Table
Version Auxiliary power Ex i output Order number Art. no. PS
Nominal voltage
UN
Max. nominal
current IN
Ex i power supply
Series 9143
24 V AC / DC 4.0 ... 5.6 V 160 mA 9143/10-065-200-10s 159820 29
9.5 ... 11.8 V 130 mA 9143/10-124-150-10s 159823 29
12.5 ... 14.7 V 140 mA 9143/10-156-160-10s 159797 29
14.6 ... 17.6 V 35 mA 9143/10-187-050-10s 159800 29
115 / 230 V AC 4.0 ... 5.6 V 160 mA 9143/10-065-200-20s 159785 29
9.5 ... 11.8 V 130 mA 9143/10-124-150-20s 159791 29
12.5 ... 14.7 V 140 mA 9143/10-156-160-20s 159829 29
14.6 ... 17.6 V 35 mA 9143/10-187-050-20s 159832 29
Note Other versions - see Automation Catalogue
The order code above is with screw type removable terminals.
Technical Data
Explosion protection
Version 9143/10-...-...-10.
24 V AC / DC
9143/10-...-...-20.
115 / 230 V AC
Global (IECEx)
Gas, dust and mining IECEx BVS 12.0009X IECEx BVS 12.0009X
Ex nA [ib Gb] IIC/IIB T4 Gc
[Ex ib Db] IIIC
[Ex ib Gb] IIC/IIB
[Ex ib Db] IIIC
[Ex ib Mb] I [Ex ib Mb] I
Europe (ATEX)
Gas, dust and mining BVS 05 ATEX E 152X BVS 05 ATEX E 152X
E II 3 (2) G Ex nA [ib Gb] IIC/IIB T4 Gc
E II (2) D [Ex ib Db] IIIC
E II (2) G [Ex ib Gb] IIC/IIB
E II (2) D [Ex ib Db] IIIC
E I (M2) [Ex ib Mb] I E I (M2) [Ex ib Mb] I
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),
Korea (KCs), Russia (GOST R), Serbia (SRPS), Belarus (operating authorisation)
Ship approval DNV
Kapitel_A3_KP00_en.book Seite 18 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
192013-09-10·KP00·III·en Isolators
Ex i Power Supply
Field Circuit Ex i
Series 9143
Technical Data
Safety data
Version 9143/10-065-200-.0. 9143/10-124-150-.0. 9143/10-156-160-.0. 9143/10-187-050-.0.
Max. voltage Uo 6.5 V 12.4 V 15.6 V 18.7 V
Max. current Io 200 mA 150 mA 160 mA 50 mA
Max. power Po 1.3 W 1.86 W 2.496 W 0.935 W
Further parameters
Version 9143/10-...-...-10.
24 V AC / DC
9143/10-...-...-20.
115 / 230 V AC
Installation in Zone 2, 22 and in the safe area in Zone 22 and in the safe area
Further information see respective certificate and operating
instructions
see respective certificate and operating
instructions
Auxiliary power
Version 9143/10-...-...-10.
24 V AC / DC
9143/10-...-...-20.
115 / 230 V AC
Rated voltage UN 24 V AC / DC 115 / 230 V AC
Voltage range AC: 20 ... 28 V
DC: 18 ... 35 V
85 ... 230 V AC
Kapitel_A3_KP00_en.book Seite 19 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Frequency Transmitter
Field Circuit Ex i
Series 9146
20 Isolators 2013-09-10·KP00·III·en
Series 9146 A3
11024E00
WebCode 9146A
> Speed control of rotating parts
in hazardous areas
> Most compact device in its class,
2 versions available:
– limit value switch, frequency/current
conversion, impulse divider function
within 17.6 mm width
– dual channel frequency/current conversion
within 17.6 mm width
> Line fault monitoring indicated by LED and
fault-contact contact enables easy monitoring
and prompt troubleshooting
> Broad input frequency range 0.001 ... 20 kHz
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Output Limit value contact
(per channel)
Impulse output Order number Art. no. PS
Frequency Transmitter
Field Circuit Ex i
Series 9146
1 0/4 ... 20 mA 2 NO / NC one NO selectable 9146/10-11-12s 159883 21
2 0/4 ... 20 mA without one NO selectable 9146/20-11-11s 159886 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 13.0095X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Europe (ATEX)
Gas and dust BVS 05 ATEX E 0171 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS), USA (FM), Belarus (operating authorisation)
Ship approval DNV
Safety data
Max. voltage Uo 10.5 V
Max. current Io 23.4 mA
Max. power Po 61.4 mW (linear characteristic curve)
Kapitel_A3_KP00_en.book Seite 20 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
212013-09-10·KP00·III·en Isolators
Frequency Transmitter
Field Circuit Ex i
Series 9146
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at UN, 20 mA
1 channel 55 mA
2 channels 75 mA
Ex i input
Input signal acc. to EN 60947-5-6 (NAMUR)
Input frequency 0.001 ... 20000 Hz
Output see selection table
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
Technical Data
Kapitel_A3_KP00_en.book Seite 21 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Vibration Transducer Supply Unit
Series 9147
22 Isolators 2013-09-10·KP00·III·en
Series 9147 A3
14793E00
WebCode 9147A
> For vibration, acceleration and speed
sensors in 2- and 3-wire design
> Space-saving dual-channel version
> Signal frequencies up to 50 kHz
> Easy setting by means of front-side
rotary switch
> Galvanic isolation between inputs and
outputs and auxiliary power
> For use up to SIL 2 (IEC 61508)
*) Restrictions see table explosion protection
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x*) x*)
Selection table
Version Channels Order number Art. no. PS Weight
kg
Vibration transducer
supply unit
Series 9147
1 9147/10-99-10s 212432 21 0.150
2 9147/20-99-10s 212433 21 0.210
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 12.0001 X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIC
[Ex ia Ma] I
Europe (ATEX)
Gas, dust and mining BVS 12 ATEX E 007 X
E II 3 (1)G Ex nA [ia Ga] IIC T4 Gc
E II (1)D [Ex ia Da] IIC
E I (M1) [Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (FMc), Kazakhstan (GOST K),
Russia (GOST R), USA (FM)
Ship approval DNV
Safety data
Max. voltage Uo 26.3 V
Max. current Io 88.3 mA
Max. power Po 579 mW
Insulation voltage Um 253 V
Further parameters
Installation in Zone 2
Further information see respective certificate and operating instructions
Kapitel_A3_KP00_en.book Seite 22 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
232013-09-10·KP00·III·en Isolators
Vibration Transducer Supply Unit
Series 9147
Technical Data
Electrical data
Version 1 channel
9147/10-99-10
2 channels
9147/20-99-10
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Voltage range 18 ... 31.2 V 18 ... 31.2 V
Residual ripple within
voltage range
( 3.6 VSS ( 3.6 VSS
Nominal current at UN
1 channel 75 mA – –
2 channels – – 88 mA
Power consumption at UN
1 channel 1.8 W – –
2 channels – – 2.1 W
Power dissipation at UN
1 channel 1.4W – –
2 channels – – 1.8W
Polarity reversal protection yes yes
Operation indication LED green "PWR" LED green "PWR"
Undervoltage monitoring yes (no faulty devices / output states) yes (no faulty devices / output states)
Ex i input
Input resistance 10 kΩ
Input signal -20 ... -0.5 V
Functional range -24 ... 0 V
Output current
For 3-wire operation
For 2-wire operation
Output
Output signal -20 ... -0.5 V
Internal resistance < 30 Ω
Load resistance
1 channel > 2 kΩ
2 channels > 10 kΩ
Signal transmission
Delay input / output < 7 μs
Phase fluctuation < 0.6 % / period
Transferable frequency range 0 ... 50 kHz
Ripple at a load resistance of
10 kΩ
< 60 mVss
Error limits
relative to the measuring span -0.5 ... -20 V
Temperature influence < 0.05 % / 10 K
Auxiliary power influence < 0.05 %
Load resistance influence
At RL = 3 ... 10 kΩ < 0.35 % / kΩ
DC transmission fault
At UN and 20 °C < 0.5 %
AC transmission fault
At UN and 20 °C
Electromagnetic compatibility Tested to the following standards and regulations:
EN 61326-1 Use in industrial environment
10 mA at -21 V
20 mA at -18 V
2.6 / 4.3 / 7.9 mA at -10 V
Frequency Phase fault Amplitude fault
0 ... 200 Hz ( 0.5° ±1 %
< 400 Hz ( 1.0° ±1 %
> 600 Hz ( 1.5° ±1 %
< 1 Hz ( 2.5° ±1 %
< 10 kHz ( 25° +1 / -5 %
< 20 kHz ( 50° +1 / -5 %
< 50 kHz ( 125° -30 %
Kapitel_A3_KP00_en.book Seite 23 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Transmitter Supply Unit
Field Circuit Ex i
Series 9160 Rev. F
24 Isolators 2013-09-10·KP00·III·en
Series 9160 Rev. F A3
09745E00
WebCode 9160A
> Suitable for 2-, 3-wires transmitter,
2-wires HART transmitter and mA-sources
(4-wires transmitter)
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input,
output and power supply
> Open-circuit and short-circuit monitoring
and messaging for input and output
(can be switched off)
> For use up to SIL 2,
special version up to SIL 3 (IEC 61508)
> High accuracy
*) Restrictions see table explosion protection
Variants with UL/FM approval for NEC on request
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x*) x*)
Selection Table
Output version
(control)
Channels Input Output A Output B SIL LFD* Order number Art. no. PS
0/4 ... 20 mA
active / source
with HART
1 0/4 ... 20 mA 0/4 ... 20 mA – – 2 no 9160/13-11-10s 214893 21
3 yes 9160/13-11-13s 214897 21
0/4 ... 20 mA 2 no 9160/19-11-10s 214901 21
0/4 ... 20 mA
High Power
0/4 ... 20 mA – – 2 yes 9160/14-11-11s 214899 21
2 0/4 ... 20 mA 0/4 ... 20 mA 0/4 ... 20 mA 2 no 9160/23-11-10s 214905 21
0/4 ... 20 mA
passive / sink
with HART
1 0/4 ... 20 mA passive – – 2 no 9160/13-10-10s 214837 21
2 0/4 ... 20 mA passive passive 2 no 9160/23-10-10s 214903 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
* LFD - line fault diagnosis
no - Device transmits line fault on the field side via the 4 ... 20 mA signal. Without LED / relay contact.
yes - Device transmits line fault on the field side via the 4 ... 20 mA signal. With LED / relay contact.
Kapitel_A3_KP00_en.book Seite 24 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
252013-09-10·KP00·III·en Isolators
Transmitter Supply Unit
Field Circuit Ex i
Series 9160 Rev. F
Technical Data
Output version (control) 0/4 ... 20 mA active / source with HART
Version 9160/xx-11-10 9160/xx-11-13 9160/14-11-11
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 08.0050X IECEx BVS 08.0050X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Europe (ATEX)
Gas, dust and mining DMT 03 ATEX E 010 X DMT 03 ATEX E 010 X
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
E I (M1) [Ex ia Ma] I
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
E I (M1) [Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS),
Ukraine (TR), Belarus (operating athorisation)
Ship approval DNV
Version 9160/xx-11-10 9160/xx-11-13 9160/14-11-11
Safety data
Max. voltage Uo 27 V 27 V 27 V
Max. current Io 88 mA 88 mA 112.5 mA
Max. power Po 576 mW 576 mW 731 mW
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC 24 V DC
Nominal current at UN, 20 mA
1 channel 75 mA 95 mA 95 mA
2 channels 115 mA – – – –
Ex i input
Input signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Supply voltage for transmitter ) 16 V at 20 mA
(for 2-, 3-wire)
) 16 V at 20 mA
(for 2-, 3-wire)
) 18 V at 20 mA
(for 2-, 3-wire)
Output
Output signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Load resistance RL 0 ... 600 Ω
(terminal 1+ / 2- or 5+ / 6-)
0 ... 379 Ω
(terminal 3+ / 2- or 4+ / 6-)
(with internal 221 Ω resistor
for HART)
0 ... 600 Ω
(terminal 1+ / 2-)
0 ... 379 Ω
(terminal 3+ / 2-)
(with internal 221 Ω resistor
for HART)
0 ... 600 Ω
(terminal 1+ / 2- or 5+ / 6-)
0 ... 379 Ω
(terminal 3+ / 2- or 4+ / 6-)
(with internal 221 Ω resistor
for HART)
Output version (control) 0/4 ... 20 mA passive / sink with HART
Version 9160/xx-10-10
Explosion protection
Global (IECEx)
Gas, dust and mining IECEx BVS 08.0050X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
Europe (ATEX)
Gas, dust and mining DMT 03 ATEX E 010 X
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
E I (M1) [Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS),
Ukraine (TR), Belarus (operating athorisation)
Ship approval DNV
Safety data
Max. voltage Uo 27 V
Max. current Io 88 mA
Max. power Po 576 mW
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at UN, 20 mA
1 channel 75 mA
2 channels 115 mA
Ex i input
Input signal 0/4 ... 20 mA with HART
Supply voltage for transmitter ) 16 V at 20 mA (for 2-, 3-wire)
Output
Output signal Current sink, max. 30 V with HART
Load resistance RL see data sheet
9160_xx-1x-1x_Rev_F_TransmitterSupplyUnit_KP00_III_en.fm Seite 25 Donnerstag, 16. Januar 2014 7:56 07
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Transmitter Supply Unit with Limit Contact
Field Circuit Ex i
Series 9162
26 Isolators 2013-09-10·KP00·III·en
Series 9162 A3
11025E00
WebCode 9162A
> Compact limit value switch with
2 configurable limiting values and
0/4 ... 20 mA or 4 ... 20 mA output
> Suitable for 2-, 3-wire transmitter,
2-wire HART transmitter and mA-sources
> Intrinsically safe input [Ex ia] IIC
> Open circuit / short-circuit monitoring
and messaging
> Variant for use up to SIL 2 (IEC 61508)
*) For restrictions, see Explosion protection table
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x x x Ex i
interface
x x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Input Output Limit contact SIL Order number Art. no. PS
Transmitter supply unit
with limit contact
Series 9162
1 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
2 NO / NC – – 9162/13-11-12s 160120 21
4 ... 20 mA
with HART
4 ... 20 mA
with HART
2 NO / NC 2 9162/13-11-14s 202460 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Version 9162/13-11-12 9162/13-11-14
Explosion protection
Global (IECEx)
Gas and dust IECEx FMG 10.0020X IECEx FMG 10.0020X
Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 °C
[Ex iaD]
Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 °C
[Ex iaD]
Europe (ATEX)
Gas and dust FM 06 ATEX 0008 X FM 06 ATEX 0008 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, India (PESO), Canada (cFM),
Kazakhstan (GOST K), Korea (KTL),
Russia (GOST R), Serbia (SRPS), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Canada (cFM),
Russia (GOST R), Serbia (SRPS), USA (FM),
Belarus (operating authorisation)
Ship approval DNV DNV
Kapitel_A3_KP00_en.book Seite 26 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
272013-09-10·KP00·III·en Isolators
Transmitter Supply Unit with Limit Contact
Field Circuit Ex i
Series 9162
Version 9162/13-11-12 9162/13-11-14
Safety data
Max. voltage Uo 27 V 27 V
Max. current Io 87.9 mA 87.9 mA
Max. power Po 574 mW 574 mW
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Nominal current at
UN, 20 mA
83 mA 83 mA
Output
Output signal 0/4 ... 20 mA with HART 4 ... 20 mA with HART
Load resistance RL 0 ... 600 Ω (terminal 1+ / 2-) 0 ... 600 Ω (terminal 1+ / 2-)
Limiting values
Configuration using ISpac Wizard using ISpac Wizard
Message 2 NO / NC 2 NO / NC
Switching voltage ( ± 30 V ( ± 30 V
Switching current
(resistive load)
( 100 mA ( 100 mA
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
Technical Data
9162_13-11-1x_TransmitterSupplyUnitWithLimitValue_KP00_III_en.fm Seite 27 Mittwoch, 29. Januar 2014 12:29 12
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater Input
Series 9163 Rev. B
28 Isolators 2013-09-10·KP00·III·en
Series 9163 Rev. B A3
15281E00
WebCode 9163A
> Suitable for 4-wire HART transmitters
and voltage sources
> Intrinsically safe input [Ex ia] IIC
> Galvanic Isolation between input,
output and power supply
> Open-circuit and short-circuit monitoring and
messaging (can be switched off)
> For use up to SIL 2 (IEC 61508)
*) Restrictions see table explosion protection
Variants with UL/FM approval for NEC on request
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x*) x*)
Selection Table
Version Channels Input Output LFD* Order number Art. no. PS
Isolating repeater
input
Series 9163
1 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
no 9163/13-11-10s 214914 21
passive (sink) no 9163/13-10-10s 214912 21
0/1 ... 5 V,
0/2 ... 10 V
0/4 ... 20 mA no 9163/11-81-10s 214910 21
2 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
no 9163/23-11-10s 214920 21
passive (sink) no 9163/23-10-10s 214918 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
* LFD - line fault diagnosis,
no - The device transmits a line fault detected in the field circuit via the 4 ... 20 mA signal.
Without LED / relay contact.
9163_RevB_IsolatingRepeaterHART_KP00_III_en.fm Seite 28 Donnerstag, 16. Januar 2014 8:00 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
292013-09-10·KP00·III·en Isolators
Isolating Repeater Input
Series 9163 Rev. B
Technical Data
Version 9163/.3-1.-1.. 9163/11-81-10.
Explosion protection
Global (IECEx)
Gas and dust
IECEx BVS 08.0050X IECEx BVS 08.0050X
Ex nA [ia Ga] IIC T4 Gc Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC [Ex ia Da] IIIC
[Ex ia Ma] I [Ex ia Ma] I
Europe (ATEX)
Gas and dust DMT 03 ATEX E010X DMT 03 ATEX E010X
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
[Ex ia Ma] I
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
[Ex ia Ma] I
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO),
Russia (GOST R), Serbia (SRPS),
Ukraine (TR)
IECEx, ATEX
Safety data
Max. voltage Ui 30 V 30 V
Max. current Ii 150 mA negligible
Max. power Pi 1000 mW negligible
Max. voltage Uo negligible 4.2 V
Max. current Io negligible negligible
Max. power Po – – negligible
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Nominal current at
UN, 20 mA
1 channel 80 mA 80 mA
2 channels 135 mA – –
Input signal 0/4 ... 20 mA with HART 0 ... 5 V resp. 0 ... 10 V
Output
Output signal 9163/.3-11-10.: 0/4 ... 20 mA with HART
9163/.3-10-10.: passive (sink)
0/4 ... 20 mA
Load resistance RL 0 ... 600 Ω (terminal 1+/2- resp. 5+/6-)
0 ... 479 Ω (terminal 3+/2- resp. 4+/6-)
(with internal 221 Ω resistor for HART)
0 ... 600 Ω (terminal 1+/2- resp. 5+/6-)
Kapitel_A3_KP00_en.book Seite 29 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
mA - Isolating Repeater
Series 9164
30 Isolators 2013-09-10·KP00·III·en
Series 9164 A3
08580E00
WebCode 9164A
> Interconnection of mA-sources and
active 2-wire inputs is possible
> Perfect solution to integrate 4-wire
transmitters with 2 wire I/O-cards
> Instrinsically safe input (Ex i) or
increased safety protection Ex e version
> Bidirectional HART transmission 4 ... 20 mA
> Galvanic isolation between input and output
*) Restrictions see table explosion protection
ATEX NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) x*) Installation in x*) x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Input Output Order number Art. no. PS
mA - Isolating
repeater
Series 9164
1 Ex i: 4 ... 20 mA HART
(sink)
Ex i: passive HART
(sink)
9164/13-20-06 224365 21
Ex e: 4 ... 20 mA
HART (sink)
Ex i: passive HART
(sink)
9164/13-20-08 224364 21
Technical Data
Version 9164/13-20-06 (Ex e Input) 9164/13-20-08 (Ex i Input)
Explosion protection
Europe (ATEX)
Gas and dust KEMA 04 ATEX 1236 X KEMA 04 ATEX 1298
E II 2 (1) G Ex e mb [ia Ga] IIC T4 Gb
E II (1) D Ex e mb [ia Da] IIIC
E II 2 (1) G Ex ia [ia Ga] IIC T4 Gb
E II (1) D [Ex ia Da] IIIC
Certificates and approvals
Certificates ATEX ATEX
Ship approval DNV DNV
Safety data
Input 4-wire transmitter-side
Ex e connection
Nominal voltage Un: 30 V
Nominal current In: 30 mA
Nominal power Pn: 900 mW
4-wire transmitter-side
Ex i connection
Output parameters: Uo, Io, Po = 0
Max. voltage Ui: 30 V
Max. current Ii: 150 mA
Max. power Pi: 1 W
Output 2-wire output
Output parameters: Uo, Io, Po = 0
Max. voltage Ui: 30 V
Max. current Ii: 150 mA
Max. power Pi: 1 W
2-wire output
Output parameters: Uo, Io, Po = 0
Max. voltage Ui: 30 V
Max. current Ii: 150 mA
Max. power Pi: 1 W
Auxiliary power without without
Ex i / Ex e Input
Version passive (current sink) passive (current sink)
Input signal 3.8 ... 20.5 mA with / wihout HART 3.8 ... 20.5 mA with / wihout HART
Ex i output
Version passive (current sink) passive (current sink)
Output signal 3.6 ... 21 mA with HART 3.6 ... 21 mA with HART
Kapitel_A3_KP00_en.book Seite 30 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
312013-09-10·KP00·III·en Isolators
mA - Isolating Repeater
Series 9164
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
09432E00
7 mm / 2. "2 83 12 mm / 0.4 "7
10mm/4.0"36
Kapitel_A3_KP00_en.book Seite 31 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater
Field Circuit Ex i
Series 9165
32 Isolators 2013-09-10·KP00·III·en
Series 9165 A3
09734E00
WebCode 9165A
> For intrinsically safe operation of
(HART)-control valves, i/p transmitters,
displays
> For HART output signals 0/4 ... 20 mA
> Intrinsically safe output [Ex ia] IIC
> Galvanic isolation between input,
output and power supply
> Open circuit / short-circuit monitoring and
messaging (can be switched off)
> For use up to SIL 2 (IEC 61508)
*) Restrictions see table explosion protection:
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Input Ex i output signal LFD relay Order number Art. no. PS
Isolating Repeater
Field Circuit Ex i
Series 9165
1 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
yes 9165/16-11-11s 201270 21
no 9165/16-11-10s 207909 21
2 0/4 ... 20 mA
with HART
0/4 ... 20 mA
with HART
yes 9165/26-11-11s 201272 21
no 9165/26-11-10s 207910 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
LFD - Line fault diagnostic
no - device transmits field-side line fault via 4 ... 20 mA signal via LED
yes - device transmits field-side line fault via 4 ... 20 mA signal via LED and relay contact
9165_xx-xx-1x_IsolatingRepeater_KP00_III_en.fm Seite 32 Donnerstag, 16. Januar 2014 8:11 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
332013-09-10·KP00·III·en Isolators
Isolating Repeater
Field Circuit Ex i
Series 9165
Technical Data
Global (IECEx)
Gas and dust IECEx BVS 10.0011X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Europe (ATEX)
Gas and dust DMT 03 ATEX E 012 X
E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K),
Korea (KCs) only for 9165/16-11-11., Russia (GOST R), Serbia (SRPS), Ukraine (TR),
USA (FM, UL*), Belarus (operating authorisation)
* for UL approval - special version on request
Ship approval DNV
Safety data
Max. voltage Uo 25.6 V
Max. current Io 96 mA
Max. power Po 605 mW
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at
UN, 20 mA
1 channel 55 mA
2 channels 90 mA
Input signal 0/4 ... 20 mA with HART
Ex i output
Output signal 0/4 ... 20 mA with HART
Connectable load
resistance
0 ... 800 Ω
Fault detection Ex i output
Signalization of faulty line
and power supply failure
- Contact (30 V / 100 mA) closed to ground in case of fault
- pac-Bus, floating contact (30 V / 100 mA)
(only for 9165/.6-11-11.)
Kapitel_A3_KP00_en.book Seite 33 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Isolating Repeater Loop Powered
Field Circuit Ex i
Series 9167
34 Isolators 2013-09-10·KP00·III·en
Series 9167 A3
08577E00
WebCode 9167A
> For intrinsically safe operation of
(HART)-control valves, i/p transmitters,
displays, fire and gas detectors
> For HART output signals 0/4 ... 20 mA
> Intrinsically safe output [Ex ia] IIC
> Galvanic isolation between
inputs and outputs
> Without power supply
> Very low internal resistance
> HART communication signal transmitting,
bidirectionally
> For use up to SIL 3 (IEC 61508)
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Ex i output Uo / Io / Po max. load resistance RL Order number Art. no. PS
Isolating Repeater
Loop Powered Field
Circuit Ex i
Series 9167
1 15.7 V / 60 mA / 233 mW 360 Ω 9167/11-11-00s 160238 21
25 V / 99 mA / 613 mW 800 Ω 9167/13-11-00s 160244 21
18.8 V / 107 mA / 503 mW 590 Ω 9167/14-11-00s 160250 21
2 15.7 V / 60 mA / 233 mW 360 Ω 9167/21-11-00s 160241 21
25 V / 99 mA / 613 mW 800 Ω 9167/23-11-00s 160247 21
18.8 V / 107 mA / 503 mW 590 Ω 9167/24-11-00s 160253 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Kapitel_A3_KP00_en.book Seite 34 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
352013-09-10·KP00·III·en Isolators
Isolating Repeater Loop Powered
Field Circuit Ex i
Series 9167
Technical Data
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 11.0089X
Ex nA [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Europe (ATEX)
Gas and dust BVS 04 ATEX E 082 X
E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
E II (1) D [Ex ia Da] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),
Korea (KCs) only for 9167/14-11-00, Russia (GOST R), Serbia (SRPS), Ukraine (TR),
USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Safety data
Version 9167/.1-11-00, max. 360 Ω 9167/.3-11-00, max. 800 Ω 9167/.4-11-00, max. 590 Ω
Max. voltage Uo 15.7 V 25 V 18.8 V
Max. current Io 60 mA 99 mA 107 mA
Max. power Po 233 mW 613 mW 503 mW
Auxiliary power without without without
Input signal IE 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Ex i output
Output signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART
Function range 0 ... 40 mA 0 ... 40 mA 0 ... 40 mA
Kapitel_A3_KP00_en.book Seite 35 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Switching Repeater
Field Circuit Ex i
Series 9170
36 Isolators 2013-09-10·KP00·III·en
Series 9170 A3
06528E00
WebCode 9170A
> For operation of contacts,
proximity sensors (NAMUR), optocouplers
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input,
output and auxiliary power
> Open-circuit / short-circuit monitoring and
messaging (can be switched off)
> Inversion of output signal can be adjusted
> Transmission frequency up to 10 kHz
> Can be used up to SIL 2 (relay output) or
SIL 3 (electronic output) (IEC 61508)
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x x x Ex i
interface
x x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Output version
(control)
Channels Power supply Output / channel LFD relay LFT Order number Art. no. PS
Signal relay
(125 V / 1 A)
1 24 V DC 1 change-over contact no no 9170/11-11-13s 207471 21
2 change-over contacts yes no 9170/10-11-11s 160309 21
120 ... 230 V AC 2 change-over contacts yes no 9170/10-11-21s 160318 21
2 24 V DC 1 change-over contact yes no 9170/20-10-11s 160290 21
2 NO yes no 9170/20-11-11s 160287 21
no no 9170/21-11-13s 207472 21
120 ... 230 V AC 1 change-over contact yes no 9170/20-10-21s 160300 21
2 NO yes no 9170/20-11-21s 160303 21
Power relay
(250 V / 4 A)
1 24 V DC 1 change-over contact yes no 9170/10-12-11s 160312 21
120 ... 230 V AC 1 change-over contact yes no 9170/10-12-21s 160321 21
2 change-over contacts yes no 9170/10-13-21s 160327 21
2 24 V DC 1 change-over contact yes no 9170/20-12-11s 160293 21
120 ... 230 V AC 1 change-over contact yes no 9170/20-12-21s 160306 21
Electronic
(35 V / 50 mA)
1 24 V DC 1 electronic output yes no 9170/11-14-11s 203287 21
yes 9170/11-14-12s 203288 21
2 24 V DC 1 electronic output yes no 9170/21-14-11s 203152 21
yes 9170/21-14-12s 203153 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
LFD - Line fault diagnostic
no - device transmits line fault via LED
yes - device transmits line fault via LED and relay contact
LFT - line fault transparency, device signals line fault on field side to the control directly via the signal output.
Kapitel_A3_KP00_en.book Seite 36 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
372013-09-10·KP00·III·en Isolators
Switching Repeater
Field Circuit Ex i
Series 9170
Technical Data
Version 24 V DC
9170/.0-11-11.,
9170/20-10-11.
24 V DC
9170/.1-11-13.,
9170/.1-11-14.,
9170/.1-14-12.
24 V DC
9170/.0-12-11.
Explosion protection
Global (IECEx)
Gas IECEx BVS 09.0041X IECEx BVS 09.0041X IECEx BVS 09.0041X
Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X DMT 02 ATEX E195X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
E II (1) G [Ex ia] IIC
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR),
USA (FM, UL),
Belarus (operating authorisation)
IECEx, ATEX, India (PESO),
Canada (CSA),
Kazakhstan (GOST K),
Russia (GOST R), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS),
Ukraine (TR), USA (FM, UL),
Belarus (operating authorisation)
Ship approval DNV DNV DNV
Further parameters
Installation in Zone 2, Div. 2 and
in the safe area
in Zone 2, Div. 2 and
in the safe area
in safe area
Further information see respective certificate and
operating instructions
see respective certificate and
operating instructions
see respective certificate and
operating instructions
Version 120 ... 230 V AC
9170/.0-11-21.,
9170/20-10-21.
120 ... 230 V AC
9170/.0-12-21.,
9170/.0-13-21.
Explosion protection
Global (IECEx)
Gas IECEx BVS 09.0041X IECEx BVS 09.0041X
[Ex ia] IIC, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X
E II (1) G [Ex ia] IIC
E II (1) D [Ex ia] IIIC
E II (1) G [Ex ia] IIC
E II (1) D [Ex ia] IIIC
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO),
Canada (CSA), Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS), Ukraine (TR),
USA (FM, UL), Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO), India (PESO),
Canada (CSA), Kazakhstan (GOST K), Korea (KCs)
only for 9170/10-12-21., Russia (GOST R),
Serbia (SRPS), USA (FM, UL),
Belarus (operating authorisation)
Ship approval DNV DNV
Further parameters
Installation in safe area in safe area
Further information see respective certificate and operating instructions see respective certificate and operating instructions
Safety data
Version 9170/10-..-..
(1 channel)
9170/11-..-..
(1 channel)
9170/20-..-..
(2 channels)
9170/21-..-..
(2 channels)
Inputs (channels individually)
Max. voltage Uo 10.6 V 9.6 V 10.6 V 9.6 V
Max. current Io 24 mA 10 mA 24 mA 10 mA
Max. power Po 64 mW 24 mW 64 mW 24 mW
Inputs (2 channels parallel)
Max. voltage Uo – – – – 10.6 V 9.6 V
Max. current Io – – – – 48 mA 20 mA
Max. power Po – – – – 128 mW 48 mW
Version 24 V DC
9170/..-1.-1.
120 ... 230 V AC
9170/.0-1.-21.
Auxiliary power
Nominal voltage UN 24 V DC 120 ... 230 V AC
Input signal acc. to EN 60947-5-6 (NAMUR) acc. to EN 60947-5-6 (NAMUR)
Output see selection table see selection table
Error detection Ex i input
Message of line fault and
auxiliary power failure
- Contact in the output circuit (35 V / 50 mA) opens in
case of fault (only at 9170/.1-14-12.)
- contact (30 V / 100 mA), closed to ground in
case of fault *)
- pac-Bus, floating contact (30 V / 100 mA) *)
*) not at 9170/.1-11-13.
none
Kapitel_A3_KP00_en.book Seite 37 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
I.S. Relay Module
Series 9172
38 Isolators 2013-09-10·KP00·III·en
Series 9172 A3
08578E00
WebCode 9172A
> For binary signal and control circuits
> Intrinsically safe inputs or outputs [Ex ia] IIC
> Galvanic isolation between
inputs and outputs
> For use up to SIL 2 (IEC 61508)
*) For restrictions, see Explosion Protection table
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Input Output / channel Order number Art. no. PS
I.S. relay module
Series 9172
1 Ex i signal 1 change over contact
(250 V / 4 A)
9172/10-11-00s 160359 21
Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/12-11-00s 169651 21
Non-Ex i signal Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/11-11-00s 160366 21
2 Ex i signal 1 change over contact
(250 V / 4 A)
9172/20-11-00s 160363 21
Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/22-11-00s 169653 21
Non-Ex i signal Ex i / I.S., 1 change over contact
(125 V / 4 A, 30 V / 4 A)
9172/21-11-00s 160369 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 09.0002X
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
Europe (ATEX)
Gas and dust BVS 04 ATEX E 097 X
E II 3 (1) G Ex nA nC [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),
Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Kapitel_A3_KP00_en.book Seite 38 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
392013-09-10·KP00·III·en Isolators
I.S. Relay Module
Series 9172
Technical Data
Safety data
Version 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00
Inputs
Max. voltage Ui 30 V – – 30 V
Max. current Ii 150 mA – – 150 mA
Max. power Pi 1.3 W – – 1.3 W
Outputs (contact) – –
Internal capacitance Ci negligible negligible negligible
Internal inductance Li negligible negligible negligible
Isolation voltage 253 V AC 253 V AC 253 V AC
for connection of intrinsically safe circuits with:
max. voltage Ui
max. current Ii
125 V AC
4 A
125 V DC
0.25 A
60 V DC
0.3 A
30 V DC
4 A
Further parameters
Version 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00
Installation in Zone 2, Div. 2 and
in the safe area *)
in Zone 2, Div. 2 and
in the safe area
in Zone 2, Div. 2 and
in the safe area *)
*) in Zone 2 max. contact load
capacity 125 V / 4 A
– – *) in Zone 2 max. contact load
capacity 125 V / 4 A
Further information see respective certificate and
operating instructions
see respective certificate and
operating instructions
see respective certificate and
operating instructions
Auxiliary power
Supply without without without
Max. power losses per
channel
0.4 W 0.4 W 0.4 W
Input
Input signal Ex i non-Ex i Ex i
Switching signal 12 ... 30 V 12 ... 31.2 V 12 ... 30 V
Current consumption < 16 mA at 12 V
< 11 mA at 24 ... 30 V
< 16 mA at 12 V
< 11 mA at 24 ... 31.2 V
< 16 mA at 12 V
< 11 mA at 24 ... 30 V
Output see Selection Table see Selection Table see Selection Table
Accessories and Spare Parts
Designation Description Art. no. PS Weight
kg
Relay modules for
installation in Zone 1
The modules 8510/122-06-6..-00 contain relay modules of Series 9172.
If 8510 modules are installed in an enclosure of the degree of protection Ex e
(e.g. Type 8150 or 8146), installation in Zone 1 is possible.
165514 19 1.470
165531 19 1.470
200381 19 1.470
220076 19 1.470
Relay modules Type 9172 Modules Type 8510
9172/10-11-00s 8510/122-06-600-00
9172/20-11-00s 8510/122-06-601-00
9172/21-11-00s 8510/122-06-602-00
9172/22-11-00s 8510/122-06-604-00
Kapitel_A3_KP00_en.book Seite 39 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Electronic Relay
Series 9174
40 Isolators 2013-09-10·KP00·III·en
Series 9174 A3
02133E00
WebCode 9174A
> Ex i control for switching Ex e loads
> Maintenance-free and electronic switching
> Compact design (width 12 mm)
> Installation in Zone 1 together with I/O IS1 or
FF Digital I/O coupler Series 9413
> Galvanic isolation between input and output
ATEX
Zone 0 1 2 20 21 22
Ex i interface x x x x
For use in x x x x
Selection Table
Version Channels Input Output Order number Art. no. PS Weight
kg
Electronic relay
Series 9174
1 Ex i Ex e, 48 V DC, 2 A 9174/10-14-00 212340 29 0.110
Ex e, 250 V UC, 1 A 9174/10-15-00 212431 29 0.110
Technical Data
Explosion protection
Europe (ATEX)
Gas and dust applied for
EII 2 G Ex e mb [ib Gb] IIC T4 Gb
E II (2) D [Ex ib Db] IIIC
Version 9174/10-14-10 9174/10-15-10
Safety data
Max. voltage Ui 28 V 28 V
Max. current Li 150 mA 150 mA
Max. power Pi 780 mW 780 mW
Internal capacitance Ci negligible negligible
Internal inductance Li negligible negligible
Isolation voltage 253 V 253 V
Rated operational current
Ex e back-up fuse 2 A 3.15 A
Max. power dissipation 0.85 W 1.6 W
Ex i input
Switching level for
ON / OFF
ON 11 ... 28 V 11 ... 28 V
OFF 0 ... 5 V 0 ... 5 V
Control current < 15 mA < 15 mA
Ex e output
Max. voltage 48 V DC 250 V AC / DC
Max. current 2 A 1 A
Min. voltage 5 V DC 90 V AC / 40 V DC
Min. current 2 mA 10 mA
Max. switching frequency 300 Hz 300 Hz
Kapitel_A3_KP00_en.book Seite 40 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
412013-09-10·KP00·III·en Isolators
Electronic Relay
Series 9174
Dimensional Drawings (All Dimensions in mm / inch) - Subject to Alterations
14836E00
101,5 mm / 3.99 "
90mm/3.54"
108,8 mm / 4.28 "
7,5mm/0.29"
92mm/3.62"
79mm/3.11"12,2mm/0.48"
Kapitel_A3_KP00_en.book Seite 41 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output
Series 9175
42 Isolators 2013-09-10·KP00·III·en
Series 9175 A3
09822E00
WebCode 9175A
> For intrinsically safe operation of
I.S. solenoid valves and indicators
> Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
> Galvanic isolation between input,
output and power supply
> Open-circuit and short-circuit monitoring
(can be switched off)
> For use up to SIL 3 (IEC 61508)
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x x x Ex i
interface
x x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels No-load
voltage Uout
Max. output
current Iout max
Internal
resistance Ri
Order number Art. no. PS
Binary output
Series 9175
1 10 V 60 mA 150 Ω 9175/10-12-11s 160398 21
17.5 V 45 mA 130 Ω 9175/10-14-11s 160410 21
25 V 35 mA 250 Ω 9175/10-16-11s 160416 21
2 10 V 60 mA / 120 mA *) 150 Ω / 75 Ω *) 9175/20-12-11s 160404 21
17.5 V 45 mA / 90 mA *) 130 Ω / 65 Ω *) 9175/20-14-11s 160413 21
25 V 35 mA / 70 mA *) 250 Ω / 125 Ω *) 9175/20-16-11s 160419 21
*) Parallel connection of the outputs possible; thus, doubling of the output current.
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Kapitel_A3_KP00_en.book Seite 42 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
432013-09-10·KP00·III·en Isolators
Binary Output
Series 9175
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0050X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 03 ATEX E 043 X
E II 3 (1) G Ex nA nC [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation)
Ship approval DNV
Safety data
Version 9175/.0-12-11. 9175/.0-14-11. 9175/.0-16-11.
Max. values per output
Max. voltage Uo 11.3 V 19.6 V 11.3 V
Max. current Io 75 mA 150 / 60 mA 110 / 50 mA
Max. power Po 210 mW 732 mW 760 mW
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current
(at UN, Iout max)
80 mA / 140 mA
Input
Voltage for ON / OFF
ON 15 ... 31.2 V
OFF 0 ... 5 V
Control circuit < 5 mA
Ex i output see selection table
Fault detection Ex i output
Signalization of faulty line
and power supply failure
- Contact (30 V / 100 mA) closed to ground in case of fault
- pac-Bus, floating contact (30 V / 100 mA)
Kapitel_A3_KP00_en.book Seite 43 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output with Line Fault Transparency
Series 9175
44 Isolators 2013-09-10·KP00·III·en
Series 9175 A3
07439E00
WebCode 9175A
> For intrinsically safe operation of
I.S. solenoid valves and indicators
> Intrinsically safe output [Ex ia] IIC
> Line fault transparency (LFT):
line fault signalling directly via output on
PLC / DCS
> For use up to SIL 2 (IEC 61508)
ATEX / IECEx
Zone 0 1 2 20 21 22
Ex i interface x x x x x x
Installation in x x
Selection Table
Version Channels No-load voltage
Uout
Max. output
current Iout max
Internal
resistance Ri
Order number Art. no. PS
Binary output
with line fault
transparency
Series 9175
1 10 V 60 mA 150 Ω 9175/10-12-12s 168456 21
17.5 V 45 mA 130 Ω 9175/10-14-12s 168458 21
25 V 35 mA 250 Ω 9175/10-16-12s 168460 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Kapitel_A3_KP00_en.book Seite 44 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
452013-09-10·KP00·III·en Isolators
Binary Output with Line Fault Transparency
Series 9175
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0050X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 03 ATEX E 043 X
E II 3 (1) G Ex nA nC [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates IECEx, ATEX, India (PESO), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR),
Belarus (operating authorisation)
Ship approval DNV
Max. values per output
Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12.
Max. voltage Uo 11.3 V 19.6 V 11.3 V
Max. current Io 110 / 50 mA 150 / 60 mA 75 mA
Max. power Po 760 mW 732 mW 210 mW
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC 24 V DC
Current consumption
Device draws its power from auxiliary power or signal cable as a function of its switching state.
Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12.
Switching state Input = Output Input = Output Input = Output
Switching state OFF
Auxiliary power rated
current IN
40 mA 35 mA 30 mA
Switching state ON
Auxiliary power rated
current IN
14 mA 14 mA 14 mA
Signal input rated
current IN
90 mA 80 mA 50 mA
Power consumption 2.5 W 2.26 W 1.5 W
Power loss 1.92 W 1.73 W 1.4 W
Input
Voltage for ON / OFF
ON 15 ... 31.2 V
OFF 0 ... 5 V
Control circuit < 5 mA
Ex i output see selection table
Fault detection Ex i output
Signalization of faulty line
and power supply failure
- contact on the signal input open in case of fault
- pac-Bus, floating contact (30 V / 100 mA)
Kapitel_A3_KP00_en.book Seite 45 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Binary Output without Power Supply
Series 9176
46 Isolators 2013-09-10·KP00·III·en
Series 9176 A3
10495E00
WebCode 9176A
> For intrinsically safe operation of
Ex i solenoid valves, indicators and horns
> Power supply by control circuit, loop powered
> Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC
> Galvanic isolation
between inputs and outputs
> For use up to SIL 3 (IEC 61508)
*) Restrictions see table explosion protection
ATEX NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x x x Ex i
interface
x x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels No-load voltage
Uout
Max. output
current Iout max
Internal
resistance Ri
Order number Art. no. PS
Binary output
without power supply
Series 9176
1 10 V 60 mA 150 Ω 9176/10-12-00s 160452 21
17.5 V 45 mA 130 Ω 9176/10-14-00s 160459 21
25 V 29 mA 320 Ω 9176/10-15-00s 160472 21
35 mA 250 Ω 9176/10-16-00s 160465 21
43 mA 460 Ω 9176/10-17-00s 200546 21
2 10 V 60 mA / 120 mA *) 150 Ω / 75 Ω *) 9176/20-12-00s 160456 21
17.5 V 45 mA / 90 mA *) 130 Ω / 65 Ω *) 9176/20-14-00s 160462 21
25 V 29 mA / 58 mA *) 320 Ω / 160 Ω *) 9176/20-15-00s 165567 21
35 mA / 70 mA *) 250 Ω / 125 Ω *) 9176/20-16-00s 160468 21
43 mA / 86 mA *) 460 Ω / 230 Ω *) 9176/20-17-00s 171425 21
*) Parallel connection of the outputs possible. Doubling of the output current.
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Kapitel_A3_KP00_en.book Seite 46 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
472013-09-10·KP00·III·en Isolators
Binary Output without Power Supply
Series 9176
Technical Data
Explosion protection
Europe (ATEX)
Gas and dust BVS 04 ATEX E 075 X
E II 3 (1) G Ex nA [ia] IIC T4
E II (1) D [Ex iaD]
Certifications and certificates
Certificates ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR), USA (FM), USA (UL) - not for type 9176/..-17-00,
Belarus (operating authorisation)
Ship approval DNV
Safety data
Version 9176/..-12-... 9176/..-14-... 9176/..-15-... 9176/..-16-... 9176/..-17-...
Max. values per output
Max. voltage Uo 11.3 V 19.6 V 27.6 V 27.6 V 27.6 V
Max. current Io
[Ex ia] 75 mA 150 mA 86.5 mA 110 mA 60 mA
[Ex ib] – – 60 mA 44 mA 50 mA – –
Max. power Po 210 mW 732 mW 596 mW 760 mW 415 mW
Auxiliary power without
Input
Voltage for ON / OFF
ON 18 ... 31.2 V
OFF 0 ... 5 V
Ex i output see selection table
Kapitel_A3_KP00_en.book Seite 47 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Resistance Isolator
Series 9180
48 Isolators 2013-09-10·KP00·III·en
Series 9180 A3
11026E00
WebCode 9180A
> For intrinsically safe operartion of resistance
thermometers or other resistance sensors
> World-wide unique dual channel solution
– space saving, only 8.8 mm per channel
> For 2-, 3- and 4-wire circuits
> Resistance range from
18 ... 391 Ω or 180 ... 3910 Ω
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input,
output and power supply
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Measuring range Order number Art. no. PS
Resistance isolator
Series 9180
1 18 ... 391 Ω (Pt100) 9180/10-77-11s 160491 21
180 ... 3910 Ω (Pt1000) 9180/11-77-11s 160499 21
2 18 ... 391 Ω (Pt100) 9180/20-77-11s 160494 21
180 ... 3910 Ω (Pt1000) 9180/21-77-11s 160502 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Technical Data
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 10.0055X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust BVS 05 ATEX E 176 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Version 9180/.0 9180/.1
Certificates IECEx, ATEX, Brazil (INMETRO),
India (PESO), Kazakhstan (GOST K),
Korea (KCs) only for 9180/10-77-11.,
Russia (GOST R), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO),
India (PESO), Kazakhstan (GOST K),
Russia (GOST R), USA (FM),
Belarus (operating authorisation)
Ship approval DNV DNV
Kapitel_A3_KP00_en.book Seite 48 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
492013-09-10·KP00·III·en Isolators
Resistance Isolator
Series 9180
Version 9180/.0 9180/.1
Safety data
Max. voltage Uo 6.5 V 6.5 V
Max. current Io 16.5 mA 16.5 mA
Max. power Po 27 mW 27 mW
Ex i input
Connection type (no. of wires) 2-, 3-, 4-wire circuits 2-, 3-, 4-wire circuits
Measuring range 18 ... 391 Ω (Pt100) 180 ... 3910 Ω (Pt1000)
Middle resolution 10 m Ω 100 m Ω
Output
Output signal equals input signal (resistance)
Response time (10 ... 90 %)
Multiplexer operation
< 10 ms
Response time (Input = Output) < 1sec
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
Technical Data
9180_ResistanceIsolator_KP00_IIII_en.fm Seite 49 Donnerstag, 16. Januar 2014 8:16 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Temperature Transmitter
Field Circuit Ex i
Series 9182
50 Isolators 2013-09-10·KP00·III·en
Series 9182 A3
09746E00
WebCode 9182A
> For intrinsically safe operation of
thermocouples, resistance thermometers,
resistance transmitters, mV-sources
> One unit individually configurable for nearly
all temperature sensors
> Intrinsically safe input [Ex ia] IIC
> Galvanic isolation between input, output,
power supply and configuration interface
> Open-circuit and short-circuit monitoring and
messaging (can be switched off)
> Simple configuration with PC or DIP-switches
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x x x Ex i
interface
x x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Output Limit value contact
(per channel)
SIL Order number Art. no. PS
Temperature
transmitter
Series 9182,
field circuit Ex i
1 0/4 ... 20 mA
active / source
without – – 9182/10-51-11s 160546 21
2 9182/10-51-13s 201653 21
2 NO / NC – – 9182/10-51-12s 160549 21
2 9182/10-51-14s 201682 21
0/4 ... 20 mA
passive / sink
without 2 9182/10-59-13s 201657 21
2 0/4 ... 20 mA
active / source
without – – 9182/20-51-11s 160541 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Signal duplication due to parallel connection of inputs of 9182/20-51-.. (dual channel).
Further information see operating instruction.
Kapitel_A3_KP00_en.book Seite 50 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
512013-09-10·KP00·III·en Isolators
Temperature Transmitter
Field Circuit Ex i
Series 9182
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 09.0046X
Ex nAc nCc [ia] IIC T4
[Ex ia] IIIC
Europe (ATEX)
Gas and dust DMT 02 ATEX E 243 X
E II 3 (1) G Ex nAc nCc [ia] IIC T4
E II (1) D [Ex ia] IIIC
Certifications and certificates
Version 9182/.0-51-1. 9182/10-5.-13, SIL 2
9182/10-51-14, SIL 2
Certificates IECEx, ATEX, Brazil (INMETRO),
Canada (CSA), Kazakhstan (GOST K),
Korea (KTL) only for 9182/10-51-11,
Russia (GOST R), Ukraine (TR),
USA (FM, UL),
Belarus (operating authorisation)
IECEx, ATEX, Kazakhstan (GOST K),
Russia (GOST R), Ukraine (TR),
Belarus (operating athorisation)
Ship approval DNV DNV
Safety data
Max. voltage Uo 6.5 V
Max. current Io 19.7 mA
Max. power Po 32 mW (linear characteristic)
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current at UN
1 channel 70 mA
2 channels 80 mA
Ex i Input The input parameters can be set via the parameterising software ISpac Wizard or
DIP switch (only type 9182/.0-5.-11.).
Input resistance thermometer
Type of circuit 2-, 3-, 4-wire circuit
Input thermocouple Types B, E, J, K, N, R, S, T, L, U, XK
Input resistance transmitter
(RTD)
up to 100 k Ω
Output
(only for 9182/.0-51-1.)
Output signal 0/4 ... 20 mA (configurable)
Connectable load
resistance RL
1 channel 0 ... 750 Ω
2 channels 0 ... 600 Ω
Limiting values
Message 2 NO / NC per channel
(configurable using ISpac Wizard)
Switching voltage ( ± 30 V
Switching current
(resistive load)
( 100 mA
Error detection Ex i input
Message of line fault and
auxiliary power failure
- contact (30 V / 100 mA) closed to earth in case of error
- pac-Bus, potential-free contact (30 V / 100 mA)
Types Pt 100, Pt 500, Pt 1000
Ni 100, Ni 500, Ni 1000
9182_xx-xx-1x_TemperatureTransmitter_KP00_III_en.fm Seite 51 Donnerstag, 16. Januar 2014 8:20 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Fieldbus Isolating Repeater
Series 9185
52 Isolators 2013-09-10·KP00·III·en
Series 9185 A3
09812E00
WebCode 9185A
> For isolation between an intrinsically safe or
non-intrinsically safe RS 422 / RS 485 bus
and a non-intrinsically safe RS 232, RS 422,
RS 485 interface
> For operation of the intrinsically safe
Profibus DP (RS 485 IS to PNO standard)
> Intrinsically safe fieldbus RS 422, RS 485
[Ex ib] IIC
> Galvanic isolation between
RS 422 / RS 485 (Ex i), RS 232, RS 422,
RS 485 and power supply
> Transmission speed adjustable
between 1.2 kbit/s and 1.5 Mbit/s
> Automatic setting of transmission speed
for Profibus DP
> Bitrefresh
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i
interface
x x x x Ex i
interface
x x Ex i
interface
x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Interfaces field area Interfaces safe area Order number Art. no. PS
Fieldbus isolating
repeater
Series 9185
RS-485 IS (PNO) RS-232, RS-422, RS-485 9185/11-35-10s 160587 21
RS-422, RS-485 RS-232, RS-422, RS-485 9185/12-45-10s 160594 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Kapitel_A3_KP00_en.book Seite 52 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
532013-09-10·KP00·III·en Isolators
Fieldbus Isolating Repeater
Series 9185
Technical Data
Version 9185/11-35-10 9185/12-45-10
Explosion protection
Global (IECEx)
Gas and dust IECEx BVS 06.0004X IECEx BVS 06.0004X
Ex nAc [ib] IIC T4
[Ex ib] IIIC
Ex nAc IIC T4
Europe (ATEX)
Gas and dust DMT 02 ATEX E246X BVS 10 ATEX E 105 X
E II (2) GD [EEx ib] IIC/IIB,
E II 3 G EEx nA II T4
E II 3G Ex nAc IIC T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K), Russia (GOST R),
Serbia (SRPS), Ukraine (TR), USA (FM),
Belarus (operating authorisation)
IECEx, ATEX, Brazil (INMETRO),
India (PESO), Canada (CSA),
Kazakhstan (GOST K), Russia (GOST R),
Serbia (SRPS), Ukraine (TR), USA (FM),
Belarus (operating authorisation)
Ship approval DNV, ABS, RS DNV, ABS, RS
Version 9185/11-35-10 9185/12-45-10
Safety data
Max. voltage Uo 3.73 V – –
Max. current Io 149 mA – –
Max. power Po 139 mW – –
For connection RS 485 IS
Insulation voltage 253 V – –
Internal capacity Ci and
inductivity Li
negligible – –
Max. permissible
voltage Ui
± 4.2 V – –
Auxiliary power
Nominal voltage UN 24 V UC 24 V UC
Nominal current (24 V) 80 mA 80 mA
Interface field area
Version RS 485 IS RS 485 / RS 422 (can be set)
Level setting: RS 485 IS (PNO specification) and RS
485 IS (R. STAHL specification)
EIA RS 485, EIA RS 422
Connections Sub-D socket X3, 9-pole Sub-D socket X3, 9-pole
Transfer speed 1.2 kbit/s ... 1.5 Мbit/s 1.2 kbit/s ... 1.5 Мbit/s
Settings fixes transmission speed or automatic detection
> 9.6 kbit/s (only with Profibus DP)
fixes transmission speed or automatic detection
> 9.6 kbit/s (only with Profibus DP)
Line length depends on transmission speed and cable depends on transmission speed and cable
Terminating resistor to be set in external plug to be set in external plug
Data transmission
indication
LED green "RxD3" LED green "RxD3"
Interface safe area
Version RS 232, RS 422 (from Rev. B), RS 485 RS 232, RS 485 / RS 422 (can be set)
Settings fixed transmission speed or automatic
detection > 9.6 kbit/s (only with Profibus DP)
fixed transmission speed or automatic
detection > 9.6 kbit/s (only with Profibus DP)
Kapitel_A3_KP00_en.book Seite 53 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Fibre Optics Fieldbus Isolating Repeater
Series 9186
54 Isolators 2013-09-10·KP00·III·en
Series 9186 A3
08579E00
WebCode 9186A
> Easy installation and mainetance due to:
– Intrinsically safe optical interface
– Intrinsically safe bus connection via
RS-485 IS (PNO)
> High availability due to:
– Build-up of ring structures, redundant
Point-to-Point, line structures
– Integrated analysis of optical input signal
– Error message if critical levels of input
signal reached
> Transmission of Profibus DP, Modbus,
HART on RS-485, R. STAHL Servicebus
> 9186/12
– Installation in Zone 1 and Zone 2 possible
– Fieldbus interface for intrinsically safe
Profibus DP (PNO)
> 9186/.5
– Installation in Zone 2 possible
*) Restrictions see table explosion protection
ATEX NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 0 1 2 20 21 22 Division 1 2 1 2 1 2
9186/12-11-11:
Ex i interface
x x x x x x x x x 9186/12-11-11:
Ex i interface
x x x x x x
9186/.5-..-..:
Ex i interface
x x x 9186/.5-..-..:
Ex i interface
x x x
9186/12-11-11:
Installation in
x*) x*) x*) x*) x*) x*) x*) 9186/12-11-11:
Installation in
x*) x*) x*)
9186/.5-..-..:
Installation in
x*) x*) x*) x*) 9186/.5-..-..:
Installation in
x*) x*) x*)
Selection Table
Version Installation in Network structure Order number Art. no. PS
Fibre optics fieldbus
isolating repeater
Series 9186
Zone 1 Ring, point-to-point redundant, line 9186/12-11-11 160623 25
Zone 2 and
in the safe area
Point-to-point, end of line 9186/25-12-11 160625 25
Ring, point-to-point redundant, line 9186/15-12-11 160624 25
Technical Data
Version 9186/12 9186/.5
Installation in Zone 1 Zone 2 and in the safe area
Explosion protection
Europe (ATEX)
Gas and dust BVS 06 ATEX E 145 X BVS 07 ATEX 068 X
E II 2G (1) G Ex e mb ib [ia, op is] IIC T4
E II (1) D [Ex iaD]
E II (1) GD [Ex op is] IIC
E II 3 G Ex nA nC II T4
Certifications and certificates
Certificates ATEX, Kazakhstan (GOST K),
Russia (GOST R), USA (FM)
ATEX, Canada (UL), Kazakhstan (GOST K),
Russia (GOST R), USA (UL)
Ship approval DNV DNV
Safety data
Max. voltage Uo ± 3.7 V – –
Max. current Io 148 mA – –
Max. power Po 137 mW – –
Kapitel_A3_KP00_en.book Seite 54 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
552013-09-10·KP00·III·en Isolators
Fibre Optics Fieldbus Isolating Repeater
Series 9186
Version 9186/12 9186/.5
Installation in Zone 1 Zone 2 and in the safe area
Safety data
For connection RS 485 IS
Max. permissible
voltage Ui
± 4.2 V – –
Internal capacity Ci and
inductivity Li
negligible – –
Ex i fault-contact
Max. permissible
voltage Ui
24 V – –
Max. permissible
current Ii
600 mA – –
Internal capacity Ci and
inductivity Li
negligible – –
Auxiliary power
Nominal voltage UN 24 V DC 24 V DC
Nominal current (at UN) 67 mA 130 mA
Optical interface
Protocols protocol transparent for RS-485 interface protocol transparent for RS-485 interface
Network topologies Ring topology, line topology,
point-to-point connection
Ring topology, line topology,
point-to-point connection
Redundancy automatic switching in case of line fault automatic switching in case of line fault
Connection ST®, BFOC/2.5 connector ST®, BFOC/2.5 connector
Wavelength 850 nm 850 nm
Transmission distance ( 2000 m ( 2000 m
Electrical interfaces
Protocols PROFIBUS DP, Modbus, HART,
ServiceBus R.STAHL (IS1)
PROFIBUS DP, Modbus, HART,
ServiceBus R.STAHL (IS1)
Version RS 485 IS (PNO) RS 485
Connection Sub-D socket X1, 9-pole Sub-D socket X1, 9-pole
Bit rate 1.2 kbit/s ... 1.5 Mbit/s 9.6 kbit/s ... 1.5 Mbit/s
Fault control
Power supply failure Fault-contact is open Fault-contact is open
Transmission level is good LED green and yellow "FO signal",
fault-contact is closed
LED green and yellow "FO signal",
fault-contact is closed
Transmission level
reduced (- 1.5 dBm)
LED yellow "FO signal", fault-contact is open LED yellow "FO signal", fault-contact is open
Fibre breakage or
transmission level is
too low (- 3 dBm)
LED red "FO ERR", fault-contact is open LED red "FO ERR", fault-contact is open
Switching capacity of
fault-contact
see Ex i values max. 60 V DC, 42 V, 1 A
Mechanical data
Weight approx. 200 g approx. 200 g
Mounting type on DIN rail, EN 50022 (NS35/15; NS35/7.5) on DIN rail, EN 50022 (NS35/15; NS35/7.5)
Technical Data
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
06251E00 11335E00 11328E00
9186/12-11-11 9186/15-12-11 9186/25-12-11
126,5mm/4.98"
119mm/4.68"
99 mm / 3.89 "
106 mm / 4.17 "
35,2 mm
1.38 "
99 mm / 3.89 "
106 mm / 4.17 "
35,2 mm
1.38 "
114,2mm/4.49"
106,7mm/4.20"
99 mm / 3.89 "
106 mm / 4.17 "
35,2 mm
1.38 "
114,2mm/4.49"
106,7mm/4.20"
Kapitel_A3_KP00_en.book Seite 55 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
HART-Multiplexer
Series 9192
56 Isolators 2013-09-10·KP00·III·en
Series 9192 A3
09730E00
WebCode 9192A
> Used for connection of up to
32 HART capable field devices to an
HART management system
> Compatible to Cornerstone, AMS,
FDM, Fieldcare, PDM, PRM etc. and
FDT application
> CommDTM for integration into FDT tools
> Up to 128 HART-Multiplexer on one
PC interface
> Up to 3968 HART field devices
> Galvanic isolation between power supply,
RS 485 bus and HART channels
> For use up to SIL 3 (IEC 61508)
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Channels Order number Art. no. PS
HART-Multiplexer
Series 9192
32 9192/32-10-10 160695 21
incl. 14-core connection cable for pac-Carrier Series 9195 or HART connection board Series 9196
CommDTM available, download under the given WebCode 9192A
Kapitel_A3_KP00_en.book Seite 56 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
572013-09-10·KP00·III·en Isolators
HART-Multiplexer
Series 9192
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc II T4
Europe (ATEX)
Gas BVS 03 E 213 X
E II 3 G Ex nA II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),
USA (FM), Belarus (operating authorisation)
Ship approval DNV
Auxiliary power
Nominal voltage UN 24 V DC
Nominal current (24 V) 55 mA
System configuration
09237E00
Field device interface (HART)
Number of channels 16 or 32, setting via switch
Connection Ribbon cable, 14-pole (inclusive)
Signal HART FSK
HART Specification HART Field Communication Protocal Rev. 7.1 (downwards compatible to Rev. 4.0);
FSK Physical Layer Specification (Rev. 7.1)
RS 485 interface
Number 1
Connection Sub-D socket, 9-pole
Signal RS 485
Protocol compatible to Cornerstone, AMS, PDM, PRM, FDM
Number of HART-
Multiplexer per
bus segment
maximum 31
Kapitel_A3_KP00_en.book Seite 57 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Supply Module
Series 9193
58 Isolators 2013-09-10·KP00·III·en
Series 9193 A3
09814E00
WebCode 9193A
> Supply of 24 V DC power supply into
the pac-Bus
> Supply current up to 4 A
(for approx. 30 - 50 modules)
> Single or redundant supply,
decoupled via diodes, with LED indication
> Exchangeable fuses for both supply circuits
> Power supply failure and line fault messaging
via relay contacts
> Different operating modes can be selected
via DIP-switches
(error signal and single / redundant supply)
> Any installation on the pac-Bus
(beginning, end, middle, both sides)
*) Restrictions see table explosion protection
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Supply Error messaging Order number Art. no. PS
Supply module
Series 9193
24 V / 4 A,
primary + redundant
Line fault and power supply failure 9193/20-11-11s 160717 21
Note The order numbers listed in the table are for devices equipped with screw-type terminals.
For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with
"k" for spring-type terminals.
Kapitel_A3_KP00_en.book Seite 58 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
592013-09-10·KP00·III·en Isolators
Supply Module
Series 9193
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc nCc II T4
Europe (ATEX)
Gas BVS 03 E 213 X
E II 3 G Ex nA nC II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs),
Russia (GOST R), USA (FM)
Ship approval DNV
Input
Power supply 24 V DC
Input range 18 ... 31.2 V
Redundant supply yes, decoupled with diodes
Safety fuse 5 x 20 mm; 2 x T 4.0 A; exchangeable for prim. and red. supply
Output Supply into the pac-Bus
24 V / maximum 4 A
Error message
Power fail PF Contact (35 V / 100 mA)
Line fault LF Contact (35 V / 100 mA), closed in good conditions
Kapitel_A3_KP00_en.book Seite 59 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
pac-Bus
Series 9194
60 Isolators 2013-09-10·KP00·III·en
Series 9194 A3
02710E00
WebCode 9194A
> Supply for approx. 40 modules per segment
> Usabel for high and low profile DIN rails
(NS35/15 and NS35/7.5)
> Just snap on DIN rail without tools
> Elements can be appended at any time
> Potential free error messaging contact
for common error signal
> Gold plated contacts for
highest contact safety
> Low cost supply via terminals
> Supply module with integrated replaceable
fuses and redundant supply available
*) Restrictions see table explosion protection:
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Picture Description Order number Art. no. PS
pac-Bus
Series 9194
09885E00
pac-Bus single element,
raster distance 17.6mm
9194/31-17 160731 21
Terminal set
for pac-Bus
10374E00
5-pole, (set begin + end)
with bridge for error message chain
9194/50-01 160730 21
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc II T4
Europe (ATEX)
Gas BVS 03 E 213 X
E II 3 G Ex nA II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),
USA (FM)
Ship approval DNV
Auxiliary power
Max. current 4 A
Connection Screw terminals, 5-pole, maximum 1.5 mm2 or via supply module Series 9193
Mounting type on DIN-rail
Mounting orientation horizontal or vertical
Kapitel_A3_KP00_en.book Seite 60 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
612013-09-10·KP00·III·en Isolators
pac-Bus
Series 9194
Dimensional Drawing (All Dimensions in mm / inches) - Subject to Alterations
09858E00
3,8 mm / 0.15 "
24,2 mm / 0.95 "
17,6 mm / 0.69 "
22 mm / 0.87 "
37 mm / 1.45 "
15mm/0.59"
21mm/0.82"
Kapitel_A3_KP00_en.book Seite 61 Dienstag, 7. Januar 2014 8:03 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
pac-Carrier
Series 9195
62 Isolators 2013-09-10·KP00·III·en
Series 9195 A3
14224E00
WebCode 9195A
> pac-Carrier for 8 or 16 modules,
up to 32 signals
> All standard ISpac isolators can be used
> Integration of Ex i and non-Ex i field circuits
in one carrier
> Flexible engineering due to:
– direct allocation between I/O module and
pac-Carrier
– simple connection to
the HART managemet system
– horizontal and vertical installation possible
– installation possible in Zone 2 and Div. 2
> Easy and quick installation due to:
– customized system cables to
automation system
– installation of the isolators without tools
– installation of the carrier on DIN rail or
mounting plate
> Low out of service time of the system due to:
– redundant power supply with
fault detection contact and
exchangeable fuses
– very robust chassis proven by
the DNV approval for ship building
*) Restrictions see table explosion protection:
ATEX / IECEx NEC 505 NEC 506 NEC 500
Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2
Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x
Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*)
Selection Table
Version Number of slots Connection HART-Multiplexer Order number PS
pac-Carrier
Series 9195
8 no 9195/08A-...-... 27
9192/32 9195/08H-...-... 27
16 no 9195/16A-...-... 27
9192/32 9195/16H-...-... 27
Customer specific versions for the following DCS: Yokogawa Centum VP, Yokogawa Pro-Safe-RS,
Emerson Delta V, TRICONEX, Invensys, Honeywell, Siemens.
Detailed information about the available pac carrier versions as well as technical documentation you may
download from the internet at www.ispac.info. Engineering and shipment of new versions within 6 weeks.
Technical Data
Explosion protection
Global (IECEx)
Gas IECEx BVS 10.0042X
Ex nAc nCc II T4
Europe (ATEX)
Gas BVS 03 ATEX E 213 X
E II 3 G Ex nA nC II T4
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R),
USA (FM)
9195_pac-Carrier_KP00_III_en.fm Seite 62 Donnerstag, 16. Januar 2014 8:57 08
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
632013-09-10·KP00·III·en Isolators
pac-Carrier
Series 9195
Auxiliary power
Nominal voltage UN 24 V DC
Redundant supply yes, decoupled with diodes
Fuse 2 x TR5; T 2.0 A; exchangeable, for primary and redundant supply
Connection of field devices
Number of channels 8, 16, 32
System configuration
10154E02
HART interface
Connection - via connection of automation systems
- via HART multiplexer 9192 (only at 9195/..H-...-...)
Error message
Power fail PF Contact (35 V / 100 mA), closed in good conditions
Technical Data
i
p
Ex i
PLC or DCS
Asset
Management System
System cableSystem cable
redundant
HART RS485
HART Mux
pac Carrier 9195
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
09826E00
Type 9195/08.-...-..., 8 slots
09854E00
Type 9195/16.-...-..., 16 slots
* depending on Type, see Engineering Guide
155mm/6.10"
130mm/5.12"
144 mm / 5.67 " 1 0 mm 5. "3 / 12/
1 0 mm 5. "5 / 91/
*
*
155mm/6.10"
130mm/5.12"
286 mm / 11.26 " 1 0 mm 5. "3 / 12/
1 0 mm 5. "5 / 91/
*
*
9195_pac-Carrier_KP00_III_en.fm Seite 63 Donnerstag, 16. Januar 2014 8:57 08
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment
R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment

More Related Content

Similar to R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment

Siemens catalog tong hop sidac transformer
Siemens catalog tong hop sidac transformerSiemens catalog tong hop sidac transformer
Siemens catalog tong hop sidac transformerDien Ha The
 
WTW catalog process instrumentation in water industry
WTW catalog process instrumentation in water industryWTW catalog process instrumentation in water industry
WTW catalog process instrumentation in water industryENVIMART
 
Drager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec SheetDrager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec SheetThorne & Derrick UK
 
Presentation FIRECOM Automotive
Presentation FIRECOM AutomotivePresentation FIRECOM Automotive
Presentation FIRECOM AutomotiveAndreaMariaKappler
 
Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...
Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...
Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...Hugo Vallet
 
Drager Pac 5500 Portable Gas Detectors - Spec Sheet
Drager Pac 5500 Portable Gas Detectors - Spec SheetDrager Pac 5500 Portable Gas Detectors - Spec Sheet
Drager Pac 5500 Portable Gas Detectors - Spec SheetThorne & Derrick UK
 
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
Drager Polytron 8000 Fixed Gas Detector - Spec SheetDrager Polytron 8000 Fixed Gas Detector - Spec Sheet
Drager Polytron 8000 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...
Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...
Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...Thorne & Derrick International
 
Abtech - LV HV & Hazardous Area Electrical Enclosures and Junction Boxes
Abtech - LV HV & Hazardous Area Electrical Enclosures and Junction BoxesAbtech - LV HV & Hazardous Area Electrical Enclosures and Junction Boxes
Abtech - LV HV & Hazardous Area Electrical Enclosures and Junction BoxesThorne & Derrick International
 
Firetrace Presentation
Firetrace PresentationFiretrace Presentation
Firetrace Presentationnjgrant
 
Rtk katalog gb
Rtk katalog gbRtk katalog gb
Rtk katalog gbLy Jolie
 
Qlight simple-catalogue(en)
Qlight simple-catalogue(en)Qlight simple-catalogue(en)
Qlight simple-catalogue(en)Dien Ha The
 
Stauff Wind Energy Solutions
Stauff Wind Energy SolutionsStauff Wind Energy Solutions
Stauff Wind Energy SolutionsWaldo Sanchez
 
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetThorne & Derrick UK
 

Similar to R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment (20)

Stahl Hazardous Area Product Catalogue
Stahl Hazardous Area Product CatalogueStahl Hazardous Area Product Catalogue
Stahl Hazardous Area Product Catalogue
 
Stahl Hazardous Area Product Catalogue
Stahl Hazardous Area Product CatalogueStahl Hazardous Area Product Catalogue
Stahl Hazardous Area Product Catalogue
 
Siemens catalog tong hop sidac transformer
Siemens catalog tong hop sidac transformerSiemens catalog tong hop sidac transformer
Siemens catalog tong hop sidac transformer
 
WTW catalog process instrumentation in water industry
WTW catalog process instrumentation in water industryWTW catalog process instrumentation in water industry
WTW catalog process instrumentation in water industry
 
Drager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec SheetDrager Pac 3500 Portable Gas Detector - Spec Sheet
Drager Pac 3500 Portable Gas Detector - Spec Sheet
 
Presentation FIRECOM Automotive
Presentation FIRECOM AutomotivePresentation FIRECOM Automotive
Presentation FIRECOM Automotive
 
Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...
Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...
Valeo Air Conditioning AC system Thermal comfort loop valeoscope technical ha...
 
Drager Pac 5500 Portable Gas Detectors - Spec Sheet
Drager Pac 5500 Portable Gas Detectors - Spec SheetDrager Pac 5500 Portable Gas Detectors - Spec Sheet
Drager Pac 5500 Portable Gas Detectors - Spec Sheet
 
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
Drager Polytron 8000 Fixed Gas Detector - Spec SheetDrager Polytron 8000 Fixed Gas Detector - Spec Sheet
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
 
Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...
Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...
Abtech Hazardous Area Electrical Enclosures & Junction Boxes - High Voltage &...
 
Abtech - LV HV & Hazardous Area Electrical Enclosures and Junction Boxes
Abtech - LV HV & Hazardous Area Electrical Enclosures and Junction BoxesAbtech - LV HV & Hazardous Area Electrical Enclosures and Junction Boxes
Abtech - LV HV & Hazardous Area Electrical Enclosures and Junction Boxes
 
G450
G450G450
G450
 
Firetrace Presentation
Firetrace PresentationFiretrace Presentation
Firetrace Presentation
 
Adw535
Adw535 Adw535
Adw535
 
Rtk katalog gb
Rtk katalog gbRtk katalog gb
Rtk katalog gb
 
Qlight simple-catalogue(en)
Qlight simple-catalogue(en)Qlight simple-catalogue(en)
Qlight simple-catalogue(en)
 
Stauff Wind Energy Solutions
Stauff Wind Energy SolutionsStauff Wind Energy Solutions
Stauff Wind Energy Solutions
 
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec SheetDrager Polytron 8200 Fixed Gas Detector - Spec Sheet
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
 
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec SheetDrager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
 
Catalogue siemens-3 rf-3rw_lv1 2006
Catalogue siemens-3 rf-3rw_lv1 2006Catalogue siemens-3 rf-3rw_lv1 2006
Catalogue siemens-3 rf-3rw_lv1 2006
 

More from Thorne & Derrick International

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Thorne & Derrick International
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptThorne & Derrick International
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018Thorne & Derrick International
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick InternationalThorne & Derrick International
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-AThorne & Derrick International
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...Thorne & Derrick International
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Thorne & Derrick International
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RoweThorne & Derrick International
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandThorne & Derrick International
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DThorne & Derrick International
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...Thorne & Derrick International
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetThorne & Derrick International
 

More from Thorne & Derrick International (20)

Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...Isolation procedures for safe working on electrical systems and equipment by ...
Isolation procedures for safe working on electrical systems and equipment by ...
 
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical EqptTHORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
THORNE & DERRICK LV MV HV Jointing, Earthing, Substation & Electrical Eqpt
 
The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018The Children North East Annual Golf Day Wednesday 9th May 2018
The Children North East Annual Golf Day Wednesday 9th May 2018
 
3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International3M Electrical Products Stocked By Thorne & Derrick International
3M Electrical Products Stocked By Thorne & Derrick International
 
CATU Electrical Safety Catalogue
CATU Electrical Safety CatalogueCATU Electrical Safety Catalogue
CATU Electrical Safety Catalogue
 
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
11kV Cable Termination Heat Shrink Kits 3 Core 16-25sqmm SPS 3TIS-12X-A
 
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
THORNE + DERRICK : LV, MV & HV Cable Installation, Jointing, Substation & Ele...
 
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
Ex d Enclosures - Explosion Proof Hazardous Area Technor EJB Galvanised Steel...
 
Roxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional DrawingRoxtec Cable Transit - B Frame Dimensional Drawing
Roxtec Cable Transit - B Frame Dimensional Drawing
 
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam RowePepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
Pepperl & Fuchs SIL Training Certificate - T&D Adam Rowe
 
T&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive AtmospheresT&D Experts In Equipment For Explosive Atmospheres
T&D Experts In Equipment For Explosive Atmospheres
 
Ultrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification DemandUltrasonic Flow Meters - Customer Specification Demand
Ultrasonic Flow Meters - Customer Specification Demand
 
Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016Emtelle Fibre Optic Cables - Product Catalogue 2016
Emtelle Fibre Optic Cables - Product Catalogue 2016
 
Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016Thorne & Derrick Process Heating Brochure 2016
Thorne & Derrick Process Heating Brochure 2016
 
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282DSIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
SIRAI ASCO Numatics Solenoid Valves WRAS Approved - SIRAI L182D L282D
 
Ripley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation ToolsRipley Utility Tool Cable Preparation Tools
Ripley Utility Tool Cable Preparation Tools
 
RIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas DetectorRIDGID micro CD100 Combustible Gas Detector
RIDGID micro CD100 Combustible Gas Detector
 
Itron Fact Sheet
Itron Fact SheetItron Fact Sheet
Itron Fact Sheet
 
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
United Nations Environment Programme (UNEP) ‘2006 Report of the Refrigeration...
 
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec SheetFiloform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
Filoform FiloSeal+HD Reenterable LV HV Power Cable Duct Seal System - Spec Sheet
 

R Stahl - 2014 Catalogue Explosion Proof Hazardous Area Electrical Equipment

  • 1. 2014R.STAHLcondensedcatalogue ID 223602 2014-02/en-00 · Printed in Germany R.STAHL Am Bahnhof 30 74638 WALDENBURG · GERMANY T +49 7942 943-0 F +49 7942 943-4333 info@stahl.de www.stahl.de condensed catalogue 2014 Products for explosive gas atmospheres and areas with combustible dust Explosion protected electrical equipment Systems and components for automation Explosion protected light fittings and emergency lighting systems
  • 2. 2013-09-10·KP00·III·en Explosion Protection by R. STAHL - General Catalogue Sales R. STAHL Am Bahnhof 30 · 74638 Waldenburg (Württ.) E T +49 (0) 79 42 / 943 - 0 · F +49 (0) 79 42 / 943 - 4333 sales_ex@stahl.de · www.stahl.de R. STAHL · www.stahl.de Please find your contact person under the sales organisation, see page 588 The newest CD with the R. STAHL catalogue can be obtained from your R. STAHL partner. U2_KP_2014_en.fm Seite 1 Mittwoch, 15. Januar 2014 4:22 16
  • 3. 12013-09-10·KP00·III·en Contents Condensed Catalogue 2014 valid as of January 2014 Seite 0 General Information 2 Terms of Sale and Delivery | Pictograms | WebCode A2 Safety Barriers 4 General | Single-Channel-Safety Barriers | Dual-Channel-Safety Barriers A3 Isolators 12 Overview | Power Supply | Transmitter | Isolating Repeater | Switching Repeater Relay Module | Binary Output | HART-Multiplexer | System Components | pac-Bus | pac Carrier A4 Remote I/O 74 General Information | CPU & Power Modules | BusRail | Temperature Input Modules Input/Output Modules for Analog Signals | Input/Output Modules for Digital Signals A5 Fieldbus Technology 118 General Information | Power Supply and Diagnosis | Field Device Coupler | System Components and Accessories A6 Wireless 140 General Information | WLAN Access Point | Localisation System | WirelessHART Gateway A7 Operating and Monitoring Systems 152 System Description | Remote HMI | Open HMI | Operator Interfaces Eagle Operator Interfaces Falcon | Enclosures A8 Camera and Video Systems 234 Camera Systems for all Areas | Cameras | Video Software E2 Lighting 254 Compact Light Fittings | Light Fittings for Flourescent Lamps | Tubular Light Fittings | Emergency Light Fittings LED Cluster Lighting | Pendant Light Fittings | Bulkhead Light Fittings | Floodlights |Portable Lamps | Hand Lamps E3 Installation Equipment 326 Installation Switches | Junction Boxes | Terminal Boxes | Connection Technology for Data Networks | Plug Connectors Plugs and Sockets | Couplers | Coupler Sockets | Socket Outlet Assemblies | Maintenance Socket Isolators | Cable Reel E4 Control Devices 378 Position Switches | Radio Position Switches | Control Equipment for Panel Mounting | Control Device System Grounding Systems and Grounding Monitoring Devices | Measuring and Monitoring Equipment for Panel Mounting E5 Signalling Devices 452 Visual Signalling Devices | Audible and Visual Signalling Devices | Audible Signalling Devices | Operator Panels E6 Components for Heating Systems 496 Junction Boxes for Heat Tracing | Temperature Controller and Limiter | Thermostats | Accessories E7 Load Disconnect Switches and Motor Starters 514 Safety Switches | Load and Motor Switchgear | Motor Protection Circuit-Breakers | Standard Motor Starters Direct On-Line Motor Starters | Star-Delta Starter Combinations | Reversing Starter Combinations E8 Applications Low Voltage Systems 532 Power Distribution | Lighting and Heating Panels | Machine Controls | Battery Boxes UPS Uninterrupted Power Supply | Pressurized Apparatus E9 Components for System Solutions 544 Ex d Technology | Ex e Technology | Components for Use in Ex d and Ex e Enclosures E10 Installation Equipment and Accessories 548 Cable Glands | Cable Glands with Strain Relief | Cable Glands in Brass Breathing Glands | Stopping Plugs | Accessories Type Index - Sales Organisation / International 584 Type Index | Addresses Inhaltsverzeichnis_2014_KP00_III_en.fm Seite 1 Mittwoch, 15. Januar 2014 4:44 16
  • 4. 0 2 2013-09-10·KP00·III·en Condensed Catalogue 2014 Conditions of Sales and Delivery, Pictograms and WebCode R. STAHL Schaltgeräte GmbH Conditions of Sales and Delivery The list on hand will be valid as of 2014-01-01. All lists published up to now, including the technical specifications and the conditions of sale and delivery, will then be no longer valid and will be replaced by the list on hand. All deliveries and services are based on our “General Terms and Conditions of Delivery“. They become an integral part of the contract with each order and can be viewed under the link: www.stahl.de / DOWNLOADS Changes of technical data, dimensions, weights, design and availability are reserved. The items in this list form a focus of our program of delivery. This “Condensed Catalogue“ will be run with a higher stockpiling of devices and component parts. With our “Condensed Catalogue“ we want to make your scheduling and warehousing easier. If you will favour these devices during construction and project planning you will secure yourself particularly convenient delivery times. You may find the complete delivery program in our general catalogue and up-to-date in our online-catalogue www.stahl.de. Product Segments PS In the present “Condensed Catalogue“ you will find an associated product segment with every item number. This allows a computerized classification of defined product segments and delivery conditions. Mark-up for small-volume purchases For purchase orders with a net order value < 100 Euro we will charge a mark-up for small-volume purchases of 25 Euro net. Cancellation We will charge a processing fee of 50 Euro net for the cancellation of an order. With special productions according to the orders the cancellation costs will depend on the production stage. Repurchase Repurchases are only possible for unopened regular stock on hand, within 6 months after delivery and only with prior consultation. If the goods have been returned freight prepaid and after the quality of the returned goods has been accepted we will credit 70% of the product invoice value. Pictograms Application of the Pictograms Ex Symbol for all devices in explosion-protected design Offshore for all devices that are suitable for offshore applications. When the materials are selected special importance is put on the harsh conditions of seawater atmosphere. Shipping for all devices with ship approval Low temperature for all devices that may be used in temperatures below -20 °C High temperature for all devices that may be used in temperatures higher than +40 °C Lieferbedingungen_2014_KP00_III_en.fm Seite 2 Mittwoch, 15. Januar 2014 4:52 16
  • 5. 0 32013-09-10·KP00·III·en R. STAHL Schaltgeräte GmbH Condensed Catalogue 2014 Conditions of Sales and Delivery, Pictograms and WebCode WebCode Description By entering the WebCode on our homepage www.stahl.de you will be led directly to the respective documents.WebCode XXXXXXX WebCode Example: Installation Switch Series 8030/51 WebCode A8030 Lieferbedingungen_2014_KP00_III_en.fm Seite 3 Mittwoch, 15. Januar 2014 4:52 16
  • 6. 4 2013-09-10·KP00·III·enSafety Barrieres Safety Barriers Kapitel_A2_KP00_en.book Seite 4 Dienstag, 7. Januar 2014 7:52 07
  • 7. A2 52013-09-10·KP00·III·en Safety Barriers Contents Safety Barriers Single-Channel Safety Barriers INTRINSPAK 9001 6 Dual-Channel Safety Barriers INTRINSPAK 9002 8 Safety Barriers with Electronic Current Limitation INTRINSPAK 9004 10 You will find further information on the Internet www.stahl.de General Information Engineering Application Examples Accessories and Spare Parts Kapitel_A2_KP00_en.book Seite 5 Dienstag, 7. Januar 2014 7:52 07
  • 8. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 Safety Barriers Series 9001 / 9002 / 9004 6 Safety Barriers 2013-09-10·KP00·III·en Series 9001 / 9002 / 9004 A2 10064E00 9001: WebCode 9001A > Complete product range for all standard applications > Flexible and space saving - single and dual channel versions on 12 mm only > Time-saving installation thanks to simultaneous – snapping onto the rail and – connecting to PE and earth > Reduced inventory due to uniform exchangeable fuse *) Restrictions see table explosion protection ATEX / IECEX NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 9001, 9002: Ex i interfaces x x x x x x 9001, 9002: Ex i interfaces 9001, 9002: Ex i interfaces x x x x x x 9004: Ex i interfaces x x x x 9004: Ex i interfaces 9004: Ex i interfaces x x x Installation in x x Installation in x x Installation in x x*) x*) Technical Data Version 9001 9002 9004 Explosion protection Global (IECEx) Gas and dust IECEx PTB 09.0001X IECEx PTB 08.0057X IECEx PTB 12.0003X Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Ex nA [ib Gb] IIC T4 Gc Ex nA [ib Gb] IIB T4 Gc [Ex ib Db] IIIC Europe (ATEX) Gas and dust PTB 01 ATEX 2088 X PTB 01 ATEX 2053 X PTB 02 ATEX 2008 E II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc E II (1) D [Ex ia Da] IIIC E II 3 (1) G Ex nA [ia Ga] IIC/IIB T4 Gc E II (1) D [Ex ia Da] IIIC E II (2) GD [EEx ib] IIB/IIC E II 3 G EEx nA II T4 (Installation in Zone 2) Certifications and certificates Certificates IECEx, ATEX, Canada (CSA), Kazakhstan (operating licence), Russia (GOST R), Serbia (SRPS), Ukraine (TR), Belarus (operating authorisation) IECEx, ATEX, Canada (CSA), Kazakhstan (operating licence), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) IECEx, ATEX, Canada (CSA), Kazakhstan (operating authorisation), Russia (GOST R), Serbia (SRPS), Ukraine (TR), Belarus (operating authorisation) Further parameters Installation in Zone 2, Division 2 and in safe area Further information see respective certificate and operating instructions Enclosure material Polyamide 6 GF Degree of protection Connection type 4 cage terminals, each maximum 1.5 mm2 flexible / solid 2 PA-terminals, each maximum 4 mm2 flexible / solid Ambient temperature Ambient temperature -20 ... +60 °C Storage -20 ... +75 °C Dimensions 12 x 104 x 70 mm Weight approx. 0.115 kg according to IEC 60529 terminal enclosure: housing: IP20 IP40 9002: WebCode 9002A 9004: WebCode 9004A 9001_9002_9004_SafetyBarriers_KP00_III_en.fm Seite 6 Montag, 13. Januar 2014 10:01 10
  • 9. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 72013-09-10·KP00·III·en Safety Barriers Safety Barriers Series 9001 / 9002 / 9004 Selection table UN Rmax Safety data Schematic Order number Art. no. PS Uo Io Po V Ω V mA mW Single-Channel Safety Barriers for Negative Polarity Series 9001/00 6 32 8.6 390 839 Pic. A 9001/00-086-390-101 158434 20 24 375 28 85 595 Pic. A 9001/00-280-085-101 158344 20 319 28 100 700 Pic. A 9001/00-280-100-101 158356 20 Single-Channel Safety Barriers for Positive Polarity Series 9001/01 6 27 8.3 442 917.2 Pic. B 9001/01-083-442-101 158338 20 218 8.6 50 107.5 Pic. B 9001/01-086-050-101 158379 20 73 8.6 150 322.5 Pic. B 9001/01-086-150-101 158418 20 32 8.6 390 839 Pic. B 9001/01-086-390-101 158439 20 8 106 12.6 150 473 Pic. B 9001/01-126-150-101 158502 20 12 135 15.8 150 593 Pic. B 9001/01-158-150-101 158535 20 53 15.8 390 1541 Pic. E 9001/01-158-390-101 158509 20 262 16.8 75 315 Pic. B 9001/01-168-075-101 158568 20 16 241 19.9 100 498 Pic. B 9001/01-199-100-101 158632 20 168 19.9 150 746 Pic. B 9001/01-199-150-101 158638 20 66 19.9 390 1940 Pic. E 9001/01-199-390-101 158519 20 20 ... 35 505 25.2 57 359 Pic. C 9001/01-252-057-141 158689 20 505 25.2 60 378 Pic. D 9001/01-252-060-141 158693 20 268 25.2 100 630 Pic. M 9001/01-252-100-141 158697 20 24 666 28 50 350 Pic. B 9001/01-280-050-101 158665 20 375 28 85 595 Pic. B 9001/01-280-085-101 158351 20 319 28 100 700 Pic. B 9001/01-280-100-101 158365 20 294 28 110 770 Pic. B 9001/01-280-110-101 158380 20 198 28 165 1155 Pic. B 9001/01-280-165-101 158392 20 124 28 280 1960 Pic. E 9001/01-280-280-101 158722 20 Single-Channel Safety Barriers for Alternating Polarity Series 9001/02 0.7 134 1.6 15 6 Pic. F 9001/02-016-015-101 158669 20 43 1.6 50 20 Pic. F 9001/02-016-050-101 158673 20 20 1.6 150 60 Pic. F 9001/02-016-150-101 158681 20 20.1 1.6 150 60 Pic. F 9001/02-016-150-111 158685 20 6 354 9.3 30 69.8 Pic. F 9001/02-093-030-101 158743 20 79 9.3 150 348.8 Pic. F 9001/02-093-150-101 158753 20 36 9.3 390 906.8 Pic. F 9001/02-093-390-101 158755 20 Single-Channel Diode Return Barriers for Positive Polarity Series 9001/03 16 – – 19.9 0 0 Pic. G 9001/03-199-000-101 158475 20 24 – – 28 0 0 Pic. G 9001/03-280-000-101 158486 20 Single-Channel Safety Barriers for Transmitter Series 9001/51 20 ... 35 – – 28 110 770 Pic. K 9001/51-280-110-141 158530 20 – – 28 91 637 Pic. L 9001/51-280-091-141 158524 20 Kapitel_A2_KP00_en.book Seite 7 Dienstag, 7. Januar 2014 7:52 07
  • 10. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 8 2013-09-10·KP00·III·en Safety Barriers Series 9001 / 9002 / 9004 Safety Barriers Schematic for Single-Channel Safety Barriers Series 9001 09405E00 09406E00 09407E00 Picture A Picture B Picture C 09408E00 09409E00 09410E00 Picture D Picture E Picture F 09411E00 09415E00 09416E00 Picture G Picture K Picture L 09417E00 Picture M + UN + UN Ex i Selection table Channel UN Rmin Rmax Safety data Schematic Order number Art. no. PS Uo Io Po V Ω Ω V mA mW Dual-Channel Safety Barriers Polarity: - / - Series 9002/00 1 2 1+2 22.5 17.5 - - 321 416 - - 358 463 - - 26 20 26 87 51 138 540 245 785 Pic. C 9002/00-260-138-001 158867 20 Dual-Channel Safety Barriers Polarity: + / - Series 9002/10 1 2 1+2 6 6 - - 490 490 - - 543 543 - - 9.33 9.33 18.7 20 20 20 50 50 90 Pic. A 9002/10-187-020-001 158937 20 1 2 1+2 6 6 - - 42 42 - - 49 49 - - 9.33 9.33 18.7 270 270 270 630 630 1260 Pic. A 9002/10-187-270-001 158933 20 Kapitel_A2_KP00_en.book Seite 8 Dienstag, 7. Januar 2014 7:52 07
  • 11. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 92013-09-10·KP00·III·en Safety Barriers Safety Barriers Series 9001 / 9002 / 9004 Dual-Channel Safety Barriers Polarity: + / + Series 9002/11 1 2 1+2 16 16 - - 1423 1423 - - 1576 1576 - - 19.9 19.9 19.9 15 15 30 75 75 150 Pic. B 9002/11-199-030-001 158929 20 1 2 1+2 22.5 17.5 - - 321 416 - - 358 463 - - 26 20 26 87 51 138 570 260 850 Pic. B 9002/11-260-138-001 158870 20 1 2 1+2 25 25 - - 321 321 - - 358 358 - - 28 28 28 93 93 186 650 650 1300 Pic. B 9002/11-280-186-001 158848 20 Dual-Channel Safety Barriers Safety Barrier Polarity: + / Signal Barrier Polarity: + Series 9002/13 1 2 1+2 16 16 - - 95 - - - - 108 - - - - 19.9 19.9 19.9 222 3 225 1100 15 1120 Pic. F 9002/13-199-225-001 158921 20 1 2 1+2 20 - 35 22 - - 216 - - - - 243 - - - - 25.2 25.2 25.2 118 0 121 740 20 760 Pic. N 9002/13-252-121-041 158830 20 1 2 1+2 24 24 - - 321 - - - - 358 - - - - 28 28 28 90 3 93 630 21 651 Pic. F 9002/13-280-093-001 158852 20 1 2 1+2 20 - 35 26 - - 292 - - - - 327 - - - - 28 28 28 97 0 100 679 21 700 Pic. G 9002/13-280-100-041 158818 20 1 2 1+2 24 24 - - 269 - - - - 290 - - - - 28 28 28 107 3 110 749 21 770 Pic. F 9002/13-280-110-001 158857 20 Dual-Channel Safety Barriers Polarity: ~ / ~ Series 9002/22 1 2 1+2 0.7 0.7 1.4 19.9 19.9 - - 20.1 20.1 - - 1.6 1.6 3.2 150 150 300 60 60 120 Pic. J 9002/22-032-300-111 158954 20 1 2 1+2 9 9 18 158 158 - - 177 177 - - 12 12 24 80 80 160 240 240 480 Pic. M 9002/22-240-160-001 158948 20 Dual-Channel Safety Barriers Signal Barrier Polarity: + / Signal Barrier Polarity: + Series 9002/33 1 2 1+2 25.5 25.5 - - 0 - - - - 0 - - - - 28 28 28 0 0 0 0 0 0 Pic. I 9002/33-280-000-001 158913 20 Dual-Channel Safety Barriers Star Barrier / Star Barrier Series 9002/77 1 2 1+2 6 492 492 - - 545 545 - - 9.3 9.3 9.3 20 20 40 50 50 90 Pic. K 9002/77-093-040-001 158905 20 1 2 1+2 6 71 71 - - 82.1 82.1 - - 9.3 9.3 9.3 150 150 300 350 350 700 Pic. K 9002/77-093-300-001 158897 20 1 2 1+2 12 111 111 - - 126 126 - - 15 15 15 150 150 300 560 560 1130 Pic. K 9002/77-150-300-001 158889 20 1 2 1+2 24 657 657 - - 730 730 - - 28 28 28 47 47 94 330 330 660 Pic. K 9002/77-280-094-001 158877 20 Selection table Channel UN Rmin Rmax Safety data Schematic Order number Art. no. PS Uo Io Po V Ω Ω V mA mW Kapitel_A2_KP00_en.book Seite 9 Dienstag, 7. Januar 2014 7:52 07
  • 12. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 10 2013-09-10·KP00·III·en Safety Barriers Series 9001 / 9002 / 9004 Safety Barriers Schematic for Dual-Channel Safety Barriers Series 9002 09418E00 09419E00 09420E00 Picture A Picture B Picture C 09422E00 09423E00 09424E00 Picture E Picture F Picture G 09425E00 09426E00 09427E00 Picture H Picture I Picture J 09428E00 09430E00 11030E00 Picture K Picture M Picture N Selection table UN Rmax Safety data Schematic Order number Art. no. PS Uo Io Po V Ω V mA mW Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity Series 9004/01 12 30 16.8 50 840 Pic. A 9004/01-168-050-001 159060 20 24 56 28 45 1260 Pic. A 9004/01-280-045-001 159082 20 26 73 31.5 25 787.5 Pic. A 9004/01-315-025-001 159086 20 Single-Channel Safety Barriers with Electronic Current Limitation for Positive Polarity with Voltage Limitation Series 9004/51 23 ... 27 – – 20.6 50 1030 Pic. B 9004/51-206-050-001 159090 20 Schematic Single-Channel Safety Barriers with Electronic Current Limitation, Polarity + 10013E00 10014E00 Picture A Picture B Kapitel_A2_KP00_en.book Seite 10 Dienstag, 7. Januar 2014 7:52 07
  • 13. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 112013-09-10·KP00·III·en Safety Barriers Safety Barriers Series 9001 / 9002 / 9004 Kapitel_A2_KP00_en.book Seite 11 Dienstag, 7. Januar 2014 7:52 07
  • 14. 12 2013-09-10·KP00·III·enIsolators Isolators Isolators Overview of the System Components ISpac 14 General ISpac 15 Applications ISpac 16 Ex i Isolators Power Supply Ex i Power Supply ISpac 9143 18 Transmitter Frequency Transmitter ISpac 9146 20 Vibration Transducer Supply Unit ISpac 9147 22 Transmitter Supply Unit ISpac 9160 24 Transmitter Supply Unit with Limit Value ISpac 9162 26 Temperature Transmitter ISpac 9182 50 Isolating Repeater Isolating Repeater HART Input ISpac 9163 28 mA-Isolating Repeater ISpac 9164 30 Isolating Repeater ISpac 9165 32 Isolating Repeater Loop Powered ISpac 9167 34 Resistance Isolator ISpac 9180 48 Kapitel_A3_KP00_en.book Seite 12 Dienstag, 7. Januar 2014 8:03 08
  • 15. A3 132013-09-10·KP00·III·en Isolators Contents Ex i Isolators Isolating Repeater Fieldbus Isolating Repeater ISpac 9185 52 Fibre Optics Fieldbus Isolating Repeater ISpac 9186 54 Switching Repeater Switching Repeater ISpac 9170 36 Relay Module I.S. Relay Module ISpac 9172 38 Electronic Relay ISpac 9174 40 Binary Output Binary Output ISpac 9175 42 Binary Output with Line Fault Transparency ISpac 9175 44 Binary Output without Power Supply ISpac 9176 46 Non - Ex i Isolators Transmitter Transmitter Supply Unit ISpac 9160 66 Transmitter Supply Unit with Limit Value ISpac 9162 67 mA-Isolating Repeater ISpac 9164 68 Isolating Repeater ISpac 9165 69 Isolating Repeater Loop Powered ISpac 9167 70 Relay Module ISpac 9172 71 Temperature Transmitter ISpac 9182 73 System Components Supply Module ISpac 9193 58 HART Termination Board ISpac 9196 64 HART-Multiplexer ISpac 9192 56 pac-Bus ISpac 9194 60 pac-Carrier ISpac 9195 62 You will find further information on the Internet www.stahl.de Engineering ISpac Kapitel_A3_KP00_en.book Seite 13 Dienstag, 7. Januar 2014 8:03 08
  • 16. A3 14 2013-09-10·KP00·III·en General Isolators Overview of the System Components 15801E00 Control Level Asset PLC / DCS PLC / DCS Zone 2 / Division 2 Control Level Zone 1 / Division 1 Control Level Classic/HART meld devices Classic/HART meld devices Management Level Field Circuit Non-Ex i Field Circuit Ex i Kapitel_A3_KP00_en.book Seite 14 Dienstag, 7. Januar 2014 8:03 08
  • 17. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 General 15Isolators2013-09-10·KP00·III·en A3 11748E00 WebCode ISpacA > Versions Ex i and non-Ex i > All functions with 2 channels per module > Galvanic isolation between inputs, outputs and power supply > Modules for DIN-rail installation or comfortable system integration via pac-Carrier > Detachable terminals available in screw terminal and spring clamp terminal versions > Extended temperature range -20 … +70 °C > Installation possible in Zone 2 resp. Div. 2 > Most isolator versions can be used for applications according to „functional safety“ SIL (IEC 61508) > Customer specific engineering by R. Stahl’s competence center > macros for easier planning and engineering available *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Technical Data Mounting type on DIN-rail (NS35/15, NS35/7.5) or in pac-Carrier Versions - Screw terminals (standard) - Spring clamp terminals Removable, for wire cross-section 0.2 ... 2.5 mm2 or 2 x 1.5 mm2 flexible with or without splay protection or single-wire Degree of protection Enclosure IP30 Terminals IP20 Ambient conditions Ambient temperature Single device -20 ... +70 °C Group assembly -20 ... +60 °C The installation conditions affect the ambient temperature. Observe operating instructions. Storage temperature -40 ... +80 °C Galvanic isolation Between inputs, outputs and power supply Voltage range 18 ... 31.2 V DC / 96 ... 253 V AC (only 9170) Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) Ship approval DNV Installation in Zone 2, Div. 2 and in the safe area Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 06812E00 122mm/4.80" X 99 mm / 3.90 " Y 114,5mm/4.51" Dim. X Screw terminals 108 mm / 4.25 in Spring clamp terminals 128 mm / 5.04 in Dim. Y Series 9143, 9185, 9192 35.2 mm / 1.39 in Series 9146, 9147, 9160, 9162, 9163, 9165, 9167, 9170, 9172, 9175, 9176, 9180, 9182, 9193 17.6 mm / 0.69 in Kapitel_A3_KP00_en.book Seite 15 Dienstag, 7. Januar 2014 8:03 08
  • 18. A3 16 2013-09-10·KP00·III·en ISpac Isolators Application of isolators Symbol Application ISpac Type Ex i Signal circuit Non Ex i Signal circuit 06861E00 2-, 3-, 4-wire transmitters and current sources 9160 9162 (with limit value) Page 24 Page 26 Page 66 Page 67 06329E00 2-wire HART transmitter 9160 9162 (with limit value) Page 24 Page 26 Page 66 Page 67 07649E00 4-wire HART transmitter 9163 9164 Page 28 Page 30 Page 68 06321E00 I/P converter, HART control valve 9165 9167 Page 32 Page 34 Page 69 Page 70 06331E00 Resistance thermometers / Resistance temperature detectors (RTD) 9182 9180 Page 50 Page 48 Page 72 06332E00 Thermocouple 9182 Page 50 Page 72 06333E00 Contact, optocouple output 9170 9172 Page 36 Page 38 06334E00 NAMUR proximity switch 9170 Page 36 06326E00 Speed control, Flow measurement 9146 Page 20 06324E00 Solenoid valve, LED indicating lamp, horn 9175 9176 9172 9174 Page 42 Page 46 Page 38 Page 40 Page 71 06327E00 Fire & gas detectors 9167 Page 34 Page 70 Kapitel_A3_KP00_en.book Seite 16 Dienstag, 7. Januar 2014 8:03 08
  • 19. A3 172013-09-10·KP00·III·en Isolators ISpac 06317E00 Alarm contact 9146 9162 9182 Page 20 Page 26 Page 50 Page 67 Page 72 06330E00 HART Multiplexer 9192 9196 Page 56 Page 64 06328E00 Modbus, Profibus DP, ServiceBus R.STAHL 9185 9186 Page 52 Page 54 06318E00 Power supply of intrinsically safe users 9143 Page 18 06892E00 Vibration sensor 9147 Page 22 15280E00 Voltage source 9163 Page 28 Application of isolators Symbol Application ISpac Type Ex i Signal circuit Non Ex i Signal circuit HART Ex i V Kapitel_A3_KP00_en.book Seite 17 Dienstag, 7. Januar 2014 8:03 08
  • 20. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Ex i Power Supply Field Circuit Ex i Series 9143 18 Isolators 2013-09-10·KP00·III·en Series 9143 A3 07673E00 WebCode 9143A > For intrinsically safe power supply of 3- or 4-wire transmittters and controllers > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply 24 V AC / DC or 85 ... 230 V AC > Compact design *) Restrictions see table explosion protection ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x Installation in x*) x*) Selection Table Version Auxiliary power Ex i output Order number Art. no. PS Nominal voltage UN Max. nominal current IN Ex i power supply Series 9143 24 V AC / DC 4.0 ... 5.6 V 160 mA 9143/10-065-200-10s 159820 29 9.5 ... 11.8 V 130 mA 9143/10-124-150-10s 159823 29 12.5 ... 14.7 V 140 mA 9143/10-156-160-10s 159797 29 14.6 ... 17.6 V 35 mA 9143/10-187-050-10s 159800 29 115 / 230 V AC 4.0 ... 5.6 V 160 mA 9143/10-065-200-20s 159785 29 9.5 ... 11.8 V 130 mA 9143/10-124-150-20s 159791 29 12.5 ... 14.7 V 140 mA 9143/10-156-160-20s 159829 29 14.6 ... 17.6 V 35 mA 9143/10-187-050-20s 159832 29 Note Other versions - see Automation Catalogue The order code above is with screw type removable terminals. Technical Data Explosion protection Version 9143/10-...-...-10. 24 V AC / DC 9143/10-...-...-20. 115 / 230 V AC Global (IECEx) Gas, dust and mining IECEx BVS 12.0009X IECEx BVS 12.0009X Ex nA [ib Gb] IIC/IIB T4 Gc [Ex ib Db] IIIC [Ex ib Gb] IIC/IIB [Ex ib Db] IIIC [Ex ib Mb] I [Ex ib Mb] I Europe (ATEX) Gas, dust and mining BVS 05 ATEX E 152X BVS 05 ATEX E 152X E II 3 (2) G Ex nA [ib Gb] IIC/IIB T4 Gc E II (2) D [Ex ib Db] IIIC E II (2) G [Ex ib Gb] IIC/IIB E II (2) D [Ex ib Db] IIIC E I (M2) [Ex ib Mb] I E I (M2) [Ex ib Mb] I Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs), Russia (GOST R), Serbia (SRPS), Belarus (operating authorisation) Ship approval DNV Kapitel_A3_KP00_en.book Seite 18 Dienstag, 7. Januar 2014 8:03 08
  • 21. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 192013-09-10·KP00·III·en Isolators Ex i Power Supply Field Circuit Ex i Series 9143 Technical Data Safety data Version 9143/10-065-200-.0. 9143/10-124-150-.0. 9143/10-156-160-.0. 9143/10-187-050-.0. Max. voltage Uo 6.5 V 12.4 V 15.6 V 18.7 V Max. current Io 200 mA 150 mA 160 mA 50 mA Max. power Po 1.3 W 1.86 W 2.496 W 0.935 W Further parameters Version 9143/10-...-...-10. 24 V AC / DC 9143/10-...-...-20. 115 / 230 V AC Installation in Zone 2, 22 and in the safe area in Zone 22 and in the safe area Further information see respective certificate and operating instructions see respective certificate and operating instructions Auxiliary power Version 9143/10-...-...-10. 24 V AC / DC 9143/10-...-...-20. 115 / 230 V AC Rated voltage UN 24 V AC / DC 115 / 230 V AC Voltage range AC: 20 ... 28 V DC: 18 ... 35 V 85 ... 230 V AC Kapitel_A3_KP00_en.book Seite 19 Dienstag, 7. Januar 2014 8:03 08
  • 22. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Frequency Transmitter Field Circuit Ex i Series 9146 20 Isolators 2013-09-10·KP00·III·en Series 9146 A3 11024E00 WebCode 9146A > Speed control of rotating parts in hazardous areas > Most compact device in its class, 2 versions available: – limit value switch, frequency/current conversion, impulse divider function within 17.6 mm width – dual channel frequency/current conversion within 17.6 mm width > Line fault monitoring indicated by LED and fault-contact contact enables easy monitoring and prompt troubleshooting > Broad input frequency range 0.001 ... 20 kHz *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Output Limit value contact (per channel) Impulse output Order number Art. no. PS Frequency Transmitter Field Circuit Ex i Series 9146 1 0/4 ... 20 mA 2 NO / NC one NO selectable 9146/10-11-12s 159883 21 2 0/4 ... 20 mA without one NO selectable 9146/20-11-11s 159886 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Technical Data Explosion protection Global (IECEx) Gas, dust and mining IECEx BVS 13.0095X Ex nA nC [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas and dust BVS 05 ATEX E 0171 X E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), USA (FM), Belarus (operating authorisation) Ship approval DNV Safety data Max. voltage Uo 10.5 V Max. current Io 23.4 mA Max. power Po 61.4 mW (linear characteristic curve) Kapitel_A3_KP00_en.book Seite 20 Dienstag, 7. Januar 2014 8:03 08
  • 23. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 212013-09-10·KP00·III·en Isolators Frequency Transmitter Field Circuit Ex i Series 9146 Auxiliary power Nominal voltage UN 24 V DC Nominal current at UN, 20 mA 1 channel 55 mA 2 channels 75 mA Ex i input Input signal acc. to EN 60947-5-6 (NAMUR) Input frequency 0.001 ... 20000 Hz Output see selection table Error detection Ex i input Message of line fault and auxiliary power failure - contact (30 V / 100 mA) closed to earth in case of error - pac-Bus, potential-free contact (30 V / 100 mA) Technical Data Kapitel_A3_KP00_en.book Seite 21 Dienstag, 7. Januar 2014 8:03 08
  • 24. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Vibration Transducer Supply Unit Series 9147 22 Isolators 2013-09-10·KP00·III·en Series 9147 A3 14793E00 WebCode 9147A > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 kHz > Easy setting by means of front-side rotary switch > Galvanic isolation between inputs and outputs and auxiliary power > For use up to SIL 2 (IEC 61508) *) Restrictions see table explosion protection ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x x x Installation in x*) x*) Selection table Version Channels Order number Art. no. PS Weight kg Vibration transducer supply unit Series 9147 1 9147/10-99-10s 212432 21 0.150 2 9147/20-99-10s 212433 21 0.210 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Technical Data Explosion protection Global (IECEx) Gas, dust and mining IECEx BVS 12.0001 X Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining BVS 12 ATEX E 007 X E II 3 (1)G Ex nA [ia Ga] IIC T4 Gc E II (1)D [Ex ia Da] IIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (FMc), Kazakhstan (GOST K), Russia (GOST R), USA (FM) Ship approval DNV Safety data Max. voltage Uo 26.3 V Max. current Io 88.3 mA Max. power Po 579 mW Insulation voltage Um 253 V Further parameters Installation in Zone 2 Further information see respective certificate and operating instructions Kapitel_A3_KP00_en.book Seite 22 Dienstag, 7. Januar 2014 8:03 08
  • 25. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 232013-09-10·KP00·III·en Isolators Vibration Transducer Supply Unit Series 9147 Technical Data Electrical data Version 1 channel 9147/10-99-10 2 channels 9147/20-99-10 Auxiliary power Nominal voltage UN 24 V DC 24 V DC Voltage range 18 ... 31.2 V 18 ... 31.2 V Residual ripple within voltage range ( 3.6 VSS ( 3.6 VSS Nominal current at UN 1 channel 75 mA – – 2 channels – – 88 mA Power consumption at UN 1 channel 1.8 W – – 2 channels – – 2.1 W Power dissipation at UN 1 channel 1.4W – – 2 channels – – 1.8W Polarity reversal protection yes yes Operation indication LED green "PWR" LED green "PWR" Undervoltage monitoring yes (no faulty devices / output states) yes (no faulty devices / output states) Ex i input Input resistance 10 kΩ Input signal -20 ... -0.5 V Functional range -24 ... 0 V Output current For 3-wire operation For 2-wire operation Output Output signal -20 ... -0.5 V Internal resistance < 30 Ω Load resistance 1 channel > 2 kΩ 2 channels > 10 kΩ Signal transmission Delay input / output < 7 μs Phase fluctuation < 0.6 % / period Transferable frequency range 0 ... 50 kHz Ripple at a load resistance of 10 kΩ < 60 mVss Error limits relative to the measuring span -0.5 ... -20 V Temperature influence < 0.05 % / 10 K Auxiliary power influence < 0.05 % Load resistance influence At RL = 3 ... 10 kΩ < 0.35 % / kΩ DC transmission fault At UN and 20 °C < 0.5 % AC transmission fault At UN and 20 °C Electromagnetic compatibility Tested to the following standards and regulations: EN 61326-1 Use in industrial environment 10 mA at -21 V 20 mA at -18 V 2.6 / 4.3 / 7.9 mA at -10 V Frequency Phase fault Amplitude fault 0 ... 200 Hz ( 0.5° ±1 % < 400 Hz ( 1.0° ±1 % > 600 Hz ( 1.5° ±1 % < 1 Hz ( 2.5° ±1 % < 10 kHz ( 25° +1 / -5 % < 20 kHz ( 50° +1 / -5 % < 50 kHz ( 125° -30 % Kapitel_A3_KP00_en.book Seite 23 Dienstag, 7. Januar 2014 8:03 08
  • 26. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F 24 Isolators 2013-09-10·KP00·III·en Series 9160 Rev. F A3 09745E00 WebCode 9160A > Suitable for 2-, 3-wires transmitter, 2-wires HART transmitter and mA-sources (4-wires transmitter) > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input and output (can be switched off) > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy *) Restrictions see table explosion protection Variants with UL/FM approval for NEC on request ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x x x Installation in x*) x*) Selection Table Output version (control) Channels Input Output A Output B SIL LFD* Order number Art. no. PS 0/4 ... 20 mA active / source with HART 1 0/4 ... 20 mA 0/4 ... 20 mA – – 2 no 9160/13-11-10s 214893 21 3 yes 9160/13-11-13s 214897 21 0/4 ... 20 mA 2 no 9160/19-11-10s 214901 21 0/4 ... 20 mA High Power 0/4 ... 20 mA – – 2 yes 9160/14-11-11s 214899 21 2 0/4 ... 20 mA 0/4 ... 20 mA 0/4 ... 20 mA 2 no 9160/23-11-10s 214905 21 0/4 ... 20 mA passive / sink with HART 1 0/4 ... 20 mA passive – – 2 no 9160/13-10-10s 214837 21 2 0/4 ... 20 mA passive passive 2 no 9160/23-10-10s 214903 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. * LFD - line fault diagnosis no - Device transmits line fault on the field side via the 4 ... 20 mA signal. Without LED / relay contact. yes - Device transmits line fault on the field side via the 4 ... 20 mA signal. With LED / relay contact. Kapitel_A3_KP00_en.book Seite 24 Dienstag, 7. Januar 2014 8:03 08
  • 27. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 252013-09-10·KP00·III·en Isolators Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Technical Data Output version (control) 0/4 ... 20 mA active / source with HART Version 9160/xx-11-10 9160/xx-11-13 9160/14-11-11 Explosion protection Global (IECEx) Gas, dust and mining IECEx BVS 08.0050X IECEx BVS 08.0050X Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Ex nA nC [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining DMT 03 ATEX E 010 X DMT 03 ATEX E 010 X E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), Belarus (operating athorisation) Ship approval DNV Version 9160/xx-11-10 9160/xx-11-13 9160/14-11-11 Safety data Max. voltage Uo 27 V 27 V 27 V Max. current Io 88 mA 88 mA 112.5 mA Max. power Po 576 mW 576 mW 731 mW Auxiliary power Nominal voltage UN 24 V DC 24 V DC 24 V DC Nominal current at UN, 20 mA 1 channel 75 mA 95 mA 95 mA 2 channels 115 mA – – – – Ex i input Input signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART Supply voltage for transmitter ) 16 V at 20 mA (for 2-, 3-wire) ) 16 V at 20 mA (for 2-, 3-wire) ) 18 V at 20 mA (for 2-, 3-wire) Output Output signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART Load resistance RL 0 ... 600 Ω (terminal 1+ / 2- or 5+ / 6-) 0 ... 379 Ω (terminal 3+ / 2- or 4+ / 6-) (with internal 221 Ω resistor for HART) 0 ... 600 Ω (terminal 1+ / 2-) 0 ... 379 Ω (terminal 3+ / 2-) (with internal 221 Ω resistor for HART) 0 ... 600 Ω (terminal 1+ / 2- or 5+ / 6-) 0 ... 379 Ω (terminal 3+ / 2- or 4+ / 6-) (with internal 221 Ω resistor for HART) Output version (control) 0/4 ... 20 mA passive / sink with HART Version 9160/xx-10-10 Explosion protection Global (IECEx) Gas, dust and mining IECEx BVS 08.0050X Ex nA nC [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining DMT 03 ATEX E 010 X E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates IECEx, ATEX, Brasil (INMETRO), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), Belarus (operating athorisation) Ship approval DNV Safety data Max. voltage Uo 27 V Max. current Io 88 mA Max. power Po 576 mW Auxiliary power Nominal voltage UN 24 V DC Nominal current at UN, 20 mA 1 channel 75 mA 2 channels 115 mA Ex i input Input signal 0/4 ... 20 mA with HART Supply voltage for transmitter ) 16 V at 20 mA (for 2-, 3-wire) Output Output signal Current sink, max. 30 V with HART Load resistance RL see data sheet 9160_xx-1x-1x_Rev_F_TransmitterSupplyUnit_KP00_III_en.fm Seite 25 Donnerstag, 16. Januar 2014 7:56 07
  • 28. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Transmitter Supply Unit with Limit Contact Field Circuit Ex i Series 9162 26 Isolators 2013-09-10·KP00·III·en Series 9162 A3 11025E00 WebCode 9162A > Compact limit value switch with 2 configurable limiting values and 0/4 ... 20 mA or 4 ... 20 mA output > Suitable for 2-, 3-wire transmitter, 2-wire HART transmitter and mA-sources > Intrinsically safe input [Ex ia] IIC > Open circuit / short-circuit monitoring and messaging > Variant for use up to SIL 2 (IEC 61508) *) For restrictions, see Explosion protection table ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Input Output Limit contact SIL Order number Art. no. PS Transmitter supply unit with limit contact Series 9162 1 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 2 NO / NC – – 9162/13-11-12s 160120 21 4 ... 20 mA with HART 4 ... 20 mA with HART 2 NO / NC 2 9162/13-11-14s 202460 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Technical Data Version 9162/13-11-12 9162/13-11-14 Explosion protection Global (IECEx) Gas and dust IECEx FMG 10.0020X IECEx FMG 10.0020X Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 °C [Ex iaD] Ex nAc nCc [ia] IIC T4 Ta = - 20 ... + 70 °C [Ex iaD] Europe (ATEX) Gas and dust FM 06 ATEX 0008 X FM 06 ATEX 0008 X E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC Certifications and certificates Certificates IECEx, ATEX, India (PESO), Canada (cFM), Kazakhstan (GOST K), Korea (KTL), Russia (GOST R), Serbia (SRPS), USA (FM), Belarus (operating authorisation) IECEx, ATEX, Canada (cFM), Russia (GOST R), Serbia (SRPS), USA (FM), Belarus (operating authorisation) Ship approval DNV DNV Kapitel_A3_KP00_en.book Seite 26 Dienstag, 7. Januar 2014 8:03 08
  • 29. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 272013-09-10·KP00·III·en Isolators Transmitter Supply Unit with Limit Contact Field Circuit Ex i Series 9162 Version 9162/13-11-12 9162/13-11-14 Safety data Max. voltage Uo 27 V 27 V Max. current Io 87.9 mA 87.9 mA Max. power Po 574 mW 574 mW Auxiliary power Nominal voltage UN 24 V DC 24 V DC Nominal current at UN, 20 mA 83 mA 83 mA Output Output signal 0/4 ... 20 mA with HART 4 ... 20 mA with HART Load resistance RL 0 ... 600 Ω (terminal 1+ / 2-) 0 ... 600 Ω (terminal 1+ / 2-) Limiting values Configuration using ISpac Wizard using ISpac Wizard Message 2 NO / NC 2 NO / NC Switching voltage ( ± 30 V ( ± 30 V Switching current (resistive load) ( 100 mA ( 100 mA Error detection Ex i input Message of line fault and auxiliary power failure - contact (30 V / 100 mA) closed to earth in case of error - pac-Bus, potential-free contact (30 V / 100 mA) Technical Data 9162_13-11-1x_TransmitterSupplyUnitWithLimitValue_KP00_III_en.fm Seite 27 Mittwoch, 29. Januar 2014 12:29 12
  • 30. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Isolating Repeater Input Series 9163 Rev. B 28 Isolators 2013-09-10·KP00·III·en Series 9163 Rev. B A3 15281E00 WebCode 9163A > Suitable for 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic Isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging (can be switched off) > For use up to SIL 2 (IEC 61508) *) Restrictions see table explosion protection Variants with UL/FM approval for NEC on request ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x x x Installation in x*) x*) Selection Table Version Channels Input Output LFD* Order number Art. no. PS Isolating repeater input Series 9163 1 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART no 9163/13-11-10s 214914 21 passive (sink) no 9163/13-10-10s 214912 21 0/1 ... 5 V, 0/2 ... 10 V 0/4 ... 20 mA no 9163/11-81-10s 214910 21 2 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART no 9163/23-11-10s 214920 21 passive (sink) no 9163/23-10-10s 214918 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. * LFD - line fault diagnosis, no - The device transmits a line fault detected in the field circuit via the 4 ... 20 mA signal. Without LED / relay contact. 9163_RevB_IsolatingRepeaterHART_KP00_III_en.fm Seite 28 Donnerstag, 16. Januar 2014 8:00 08
  • 31. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 292013-09-10·KP00·III·en Isolators Isolating Repeater Input Series 9163 Rev. B Technical Data Version 9163/.3-1.-1.. 9163/11-81-10. Explosion protection Global (IECEx) Gas and dust IECEx BVS 08.0050X IECEx BVS 08.0050X Ex nA [ia Ga] IIC T4 Gc Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Da] IIIC [Ex ia Ma] I [Ex ia Ma] I Europe (ATEX) Gas and dust DMT 03 ATEX E010X DMT 03 ATEX E010X E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC [Ex ia Ma] I E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC [Ex ia Ma] I Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Russia (GOST R), Serbia (SRPS), Ukraine (TR) IECEx, ATEX Safety data Max. voltage Ui 30 V 30 V Max. current Ii 150 mA negligible Max. power Pi 1000 mW negligible Max. voltage Uo negligible 4.2 V Max. current Io negligible negligible Max. power Po – – negligible Auxiliary power Nominal voltage UN 24 V DC 24 V DC Nominal current at UN, 20 mA 1 channel 80 mA 80 mA 2 channels 135 mA – – Input signal 0/4 ... 20 mA with HART 0 ... 5 V resp. 0 ... 10 V Output Output signal 9163/.3-11-10.: 0/4 ... 20 mA with HART 9163/.3-10-10.: passive (sink) 0/4 ... 20 mA Load resistance RL 0 ... 600 Ω (terminal 1+/2- resp. 5+/6-) 0 ... 479 Ω (terminal 3+/2- resp. 4+/6-) (with internal 221 Ω resistor for HART) 0 ... 600 Ω (terminal 1+/2- resp. 5+/6-) Kapitel_A3_KP00_en.book Seite 29 Dienstag, 7. Januar 2014 8:03 08
  • 32. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 mA - Isolating Repeater Series 9164 30 Isolators 2013-09-10·KP00·III·en Series 9164 A3 08580E00 WebCode 9164A > Interconnection of mA-sources and active 2-wire inputs is possible > Perfect solution to integrate 4-wire transmitters with 2 wire I/O-cards > Instrinsically safe input (Ex i) or increased safety protection Ex e version > Bidirectional HART transmission 4 ... 20 mA > Galvanic isolation between input and output *) Restrictions see table explosion protection ATEX NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) x*) Installation in x*) x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Input Output Order number Art. no. PS mA - Isolating repeater Series 9164 1 Ex i: 4 ... 20 mA HART (sink) Ex i: passive HART (sink) 9164/13-20-06 224365 21 Ex e: 4 ... 20 mA HART (sink) Ex i: passive HART (sink) 9164/13-20-08 224364 21 Technical Data Version 9164/13-20-06 (Ex e Input) 9164/13-20-08 (Ex i Input) Explosion protection Europe (ATEX) Gas and dust KEMA 04 ATEX 1236 X KEMA 04 ATEX 1298 E II 2 (1) G Ex e mb [ia Ga] IIC T4 Gb E II (1) D Ex e mb [ia Da] IIIC E II 2 (1) G Ex ia [ia Ga] IIC T4 Gb E II (1) D [Ex ia Da] IIIC Certificates and approvals Certificates ATEX ATEX Ship approval DNV DNV Safety data Input 4-wire transmitter-side Ex e connection Nominal voltage Un: 30 V Nominal current In: 30 mA Nominal power Pn: 900 mW 4-wire transmitter-side Ex i connection Output parameters: Uo, Io, Po = 0 Max. voltage Ui: 30 V Max. current Ii: 150 mA Max. power Pi: 1 W Output 2-wire output Output parameters: Uo, Io, Po = 0 Max. voltage Ui: 30 V Max. current Ii: 150 mA Max. power Pi: 1 W 2-wire output Output parameters: Uo, Io, Po = 0 Max. voltage Ui: 30 V Max. current Ii: 150 mA Max. power Pi: 1 W Auxiliary power without without Ex i / Ex e Input Version passive (current sink) passive (current sink) Input signal 3.8 ... 20.5 mA with / wihout HART 3.8 ... 20.5 mA with / wihout HART Ex i output Version passive (current sink) passive (current sink) Output signal 3.6 ... 21 mA with HART 3.6 ... 21 mA with HART Kapitel_A3_KP00_en.book Seite 30 Dienstag, 7. Januar 2014 8:03 08
  • 33. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 312013-09-10·KP00·III·en Isolators mA - Isolating Repeater Series 9164 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 09432E00 7 mm / 2. "2 83 12 mm / 0.4 "7 10mm/4.0"36 Kapitel_A3_KP00_en.book Seite 31 Dienstag, 7. Januar 2014 8:03 08
  • 34. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Isolating Repeater Field Circuit Ex i Series 9165 32 Isolators 2013-09-10·KP00·III·en Series 9165 A3 09734E00 WebCode 9165A > For intrinsically safe operation of (HART)-control valves, i/p transmitters, displays > For HART output signals 0/4 ... 20 mA > Intrinsically safe output [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open circuit / short-circuit monitoring and messaging (can be switched off) > For use up to SIL 2 (IEC 61508) *) Restrictions see table explosion protection: ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Input Ex i output signal LFD relay Order number Art. no. PS Isolating Repeater Field Circuit Ex i Series 9165 1 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART yes 9165/16-11-11s 201270 21 no 9165/16-11-10s 207909 21 2 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART yes 9165/26-11-11s 201272 21 no 9165/26-11-10s 207910 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. LFD - Line fault diagnostic no - device transmits field-side line fault via 4 ... 20 mA signal via LED yes - device transmits field-side line fault via 4 ... 20 mA signal via LED and relay contact 9165_xx-xx-1x_IsolatingRepeater_KP00_III_en.fm Seite 32 Donnerstag, 16. Januar 2014 8:11 08
  • 35. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 332013-09-10·KP00·III·en Isolators Isolating Repeater Field Circuit Ex i Series 9165 Technical Data Global (IECEx) Gas and dust IECEx BVS 10.0011X Ex nA nC [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Europe (ATEX) Gas and dust DMT 03 ATEX E 012 X E II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs) only for 9165/16-11-11., Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL*), Belarus (operating authorisation) * for UL approval - special version on request Ship approval DNV Safety data Max. voltage Uo 25.6 V Max. current Io 96 mA Max. power Po 605 mW Auxiliary power Nominal voltage UN 24 V DC Nominal current at UN, 20 mA 1 channel 55 mA 2 channels 90 mA Input signal 0/4 ... 20 mA with HART Ex i output Output signal 0/4 ... 20 mA with HART Connectable load resistance 0 ... 800 Ω Fault detection Ex i output Signalization of faulty line and power supply failure - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA) (only for 9165/.6-11-11.) Kapitel_A3_KP00_en.book Seite 33 Dienstag, 7. Januar 2014 8:03 08
  • 36. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Isolating Repeater Loop Powered Field Circuit Ex i Series 9167 34 Isolators 2013-09-10·KP00·III·en Series 9167 A3 08577E00 WebCode 9167A > For intrinsically safe operation of (HART)-control valves, i/p transmitters, displays, fire and gas detectors > For HART output signals 0/4 ... 20 mA > Intrinsically safe output [Ex ia] IIC > Galvanic isolation between inputs and outputs > Without power supply > Very low internal resistance > HART communication signal transmitting, bidirectionally > For use up to SIL 3 (IEC 61508) *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Ex i output Uo / Io / Po max. load resistance RL Order number Art. no. PS Isolating Repeater Loop Powered Field Circuit Ex i Series 9167 1 15.7 V / 60 mA / 233 mW 360 Ω 9167/11-11-00s 160238 21 25 V / 99 mA / 613 mW 800 Ω 9167/13-11-00s 160244 21 18.8 V / 107 mA / 503 mW 590 Ω 9167/14-11-00s 160250 21 2 15.7 V / 60 mA / 233 mW 360 Ω 9167/21-11-00s 160241 21 25 V / 99 mA / 613 mW 800 Ω 9167/23-11-00s 160247 21 18.8 V / 107 mA / 503 mW 590 Ω 9167/24-11-00s 160253 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Kapitel_A3_KP00_en.book Seite 34 Dienstag, 7. Januar 2014 8:03 08
  • 37. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 352013-09-10·KP00·III·en Isolators Isolating Repeater Loop Powered Field Circuit Ex i Series 9167 Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BVS 11.0089X Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Europe (ATEX) Gas and dust BVS 04 ATEX E 082 X E II 3 (1) G Ex nA [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs) only for 9167/14-11-00, Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) Ship approval DNV Safety data Version 9167/.1-11-00, max. 360 Ω 9167/.3-11-00, max. 800 Ω 9167/.4-11-00, max. 590 Ω Max. voltage Uo 15.7 V 25 V 18.8 V Max. current Io 60 mA 99 mA 107 mA Max. power Po 233 mW 613 mW 503 mW Auxiliary power without without without Input signal IE 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART Ex i output Output signal 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART 0/4 ... 20 mA with HART Function range 0 ... 40 mA 0 ... 40 mA 0 ... 40 mA Kapitel_A3_KP00_en.book Seite 35 Dienstag, 7. Januar 2014 8:03 08
  • 38. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Switching Repeater Field Circuit Ex i Series 9170 36 Isolators 2013-09-10·KP00·III·en Series 9170 A3 06528E00 WebCode 9170A > For operation of contacts, proximity sensors (NAMUR), optocouplers > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and auxiliary power > Open-circuit / short-circuit monitoring and messaging (can be switched off) > Inversion of output signal can be adjusted > Transmission frequency up to 10 kHz > Can be used up to SIL 2 (relay output) or SIL 3 (electronic output) (IEC 61508) *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Output version (control) Channels Power supply Output / channel LFD relay LFT Order number Art. no. PS Signal relay (125 V / 1 A) 1 24 V DC 1 change-over contact no no 9170/11-11-13s 207471 21 2 change-over contacts yes no 9170/10-11-11s 160309 21 120 ... 230 V AC 2 change-over contacts yes no 9170/10-11-21s 160318 21 2 24 V DC 1 change-over contact yes no 9170/20-10-11s 160290 21 2 NO yes no 9170/20-11-11s 160287 21 no no 9170/21-11-13s 207472 21 120 ... 230 V AC 1 change-over contact yes no 9170/20-10-21s 160300 21 2 NO yes no 9170/20-11-21s 160303 21 Power relay (250 V / 4 A) 1 24 V DC 1 change-over contact yes no 9170/10-12-11s 160312 21 120 ... 230 V AC 1 change-over contact yes no 9170/10-12-21s 160321 21 2 change-over contacts yes no 9170/10-13-21s 160327 21 2 24 V DC 1 change-over contact yes no 9170/20-12-11s 160293 21 120 ... 230 V AC 1 change-over contact yes no 9170/20-12-21s 160306 21 Electronic (35 V / 50 mA) 1 24 V DC 1 electronic output yes no 9170/11-14-11s 203287 21 yes 9170/11-14-12s 203288 21 2 24 V DC 1 electronic output yes no 9170/21-14-11s 203152 21 yes 9170/21-14-12s 203153 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. LFD - Line fault diagnostic no - device transmits line fault via LED yes - device transmits line fault via LED and relay contact LFT - line fault transparency, device signals line fault on field side to the control directly via the signal output. Kapitel_A3_KP00_en.book Seite 36 Dienstag, 7. Januar 2014 8:03 08
  • 39. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 372013-09-10·KP00·III·en Isolators Switching Repeater Field Circuit Ex i Series 9170 Technical Data Version 24 V DC 9170/.0-11-11., 9170/20-10-11. 24 V DC 9170/.1-11-13., 9170/.1-11-14., 9170/.1-14-12. 24 V DC 9170/.0-12-11. Explosion protection Global (IECEx) Gas IECEx BVS 09.0041X IECEx BVS 09.0041X IECEx BVS 09.0041X Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC Ex nAc nCc [ia] IIC T4, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X DMT 02 ATEX E195X E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC E II (1) G [Ex ia] IIC E II (1) D [Ex ia] IIIC Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) IECEx, ATEX, India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), USA (FM), Belarus (operating authorisation) IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) Ship approval DNV DNV DNV Further parameters Installation in Zone 2, Div. 2 and in the safe area in Zone 2, Div. 2 and in the safe area in safe area Further information see respective certificate and operating instructions see respective certificate and operating instructions see respective certificate and operating instructions Version 120 ... 230 V AC 9170/.0-11-21., 9170/20-10-21. 120 ... 230 V AC 9170/.0-12-21., 9170/.0-13-21. Explosion protection Global (IECEx) Gas IECEx BVS 09.0041X IECEx BVS 09.0041X [Ex ia] IIC, [Ex ia] IIIC [Ex ia] IIC, [Ex ia] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X E II (1) G [Ex ia] IIC E II (1) D [Ex ia] IIIC E II (1) G [Ex ia] IIC E II (1) D [Ex ia] IIIC Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs) only for 9170/10-12-21., Russia (GOST R), Serbia (SRPS), USA (FM, UL), Belarus (operating authorisation) Ship approval DNV DNV Further parameters Installation in safe area in safe area Further information see respective certificate and operating instructions see respective certificate and operating instructions Safety data Version 9170/10-..-.. (1 channel) 9170/11-..-.. (1 channel) 9170/20-..-.. (2 channels) 9170/21-..-.. (2 channels) Inputs (channels individually) Max. voltage Uo 10.6 V 9.6 V 10.6 V 9.6 V Max. current Io 24 mA 10 mA 24 mA 10 mA Max. power Po 64 mW 24 mW 64 mW 24 mW Inputs (2 channels parallel) Max. voltage Uo – – – – 10.6 V 9.6 V Max. current Io – – – – 48 mA 20 mA Max. power Po – – – – 128 mW 48 mW Version 24 V DC 9170/..-1.-1. 120 ... 230 V AC 9170/.0-1.-21. Auxiliary power Nominal voltage UN 24 V DC 120 ... 230 V AC Input signal acc. to EN 60947-5-6 (NAMUR) acc. to EN 60947-5-6 (NAMUR) Output see selection table see selection table Error detection Ex i input Message of line fault and auxiliary power failure - Contact in the output circuit (35 V / 50 mA) opens in case of fault (only at 9170/.1-14-12.) - contact (30 V / 100 mA), closed to ground in case of fault *) - pac-Bus, floating contact (30 V / 100 mA) *) *) not at 9170/.1-11-13. none Kapitel_A3_KP00_en.book Seite 37 Dienstag, 7. Januar 2014 8:03 08
  • 40. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 I.S. Relay Module Series 9172 38 Isolators 2013-09-10·KP00·III·en Series 9172 A3 08578E00 WebCode 9172A > For binary signal and control circuits > Intrinsically safe inputs or outputs [Ex ia] IIC > Galvanic isolation between inputs and outputs > For use up to SIL 2 (IEC 61508) *) For restrictions, see Explosion Protection table ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Input Output / channel Order number Art. no. PS I.S. relay module Series 9172 1 Ex i signal 1 change over contact (250 V / 4 A) 9172/10-11-00s 160359 21 Ex i / I.S., 1 change over contact (125 V / 4 A, 30 V / 4 A) 9172/12-11-00s 169651 21 Non-Ex i signal Ex i / I.S., 1 change over contact (125 V / 4 A, 30 V / 4 A) 9172/11-11-00s 160366 21 2 Ex i signal 1 change over contact (250 V / 4 A) 9172/20-11-00s 160363 21 Ex i / I.S., 1 change over contact (125 V / 4 A, 30 V / 4 A) 9172/22-11-00s 169653 21 Non-Ex i signal Ex i / I.S., 1 change over contact (125 V / 4 A, 30 V / 4 A) 9172/21-11-00s 160369 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BVS 09.0002X Ex nA nC [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Europe (ATEX) Gas and dust BVS 04 ATEX E 097 X E II 3 (1) G Ex nA nC [ia] IIC T4 E II (1) D [Ex iaD] Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) Ship approval DNV Kapitel_A3_KP00_en.book Seite 38 Dienstag, 7. Januar 2014 8:03 08
  • 41. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 392013-09-10·KP00·III·en Isolators I.S. Relay Module Series 9172 Technical Data Safety data Version 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00 Inputs Max. voltage Ui 30 V – – 30 V Max. current Ii 150 mA – – 150 mA Max. power Pi 1.3 W – – 1.3 W Outputs (contact) – – Internal capacitance Ci negligible negligible negligible Internal inductance Li negligible negligible negligible Isolation voltage 253 V AC 253 V AC 253 V AC for connection of intrinsically safe circuits with: max. voltage Ui max. current Ii 125 V AC 4 A 125 V DC 0.25 A 60 V DC 0.3 A 30 V DC 4 A Further parameters Version 9172/.0-11-00 9172/.1-11-00 9172/.2-11-00 Installation in Zone 2, Div. 2 and in the safe area *) in Zone 2, Div. 2 and in the safe area in Zone 2, Div. 2 and in the safe area *) *) in Zone 2 max. contact load capacity 125 V / 4 A – – *) in Zone 2 max. contact load capacity 125 V / 4 A Further information see respective certificate and operating instructions see respective certificate and operating instructions see respective certificate and operating instructions Auxiliary power Supply without without without Max. power losses per channel 0.4 W 0.4 W 0.4 W Input Input signal Ex i non-Ex i Ex i Switching signal 12 ... 30 V 12 ... 31.2 V 12 ... 30 V Current consumption < 16 mA at 12 V < 11 mA at 24 ... 30 V < 16 mA at 12 V < 11 mA at 24 ... 31.2 V < 16 mA at 12 V < 11 mA at 24 ... 30 V Output see Selection Table see Selection Table see Selection Table Accessories and Spare Parts Designation Description Art. no. PS Weight kg Relay modules for installation in Zone 1 The modules 8510/122-06-6..-00 contain relay modules of Series 9172. If 8510 modules are installed in an enclosure of the degree of protection Ex e (e.g. Type 8150 or 8146), installation in Zone 1 is possible. 165514 19 1.470 165531 19 1.470 200381 19 1.470 220076 19 1.470 Relay modules Type 9172 Modules Type 8510 9172/10-11-00s 8510/122-06-600-00 9172/20-11-00s 8510/122-06-601-00 9172/21-11-00s 8510/122-06-602-00 9172/22-11-00s 8510/122-06-604-00 Kapitel_A3_KP00_en.book Seite 39 Dienstag, 7. Januar 2014 8:03 08
  • 42. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Electronic Relay Series 9174 40 Isolators 2013-09-10·KP00·III·en Series 9174 A3 02133E00 WebCode 9174A > Ex i control for switching Ex e loads > Maintenance-free and electronic switching > Compact design (width 12 mm) > Installation in Zone 1 together with I/O IS1 or FF Digital I/O coupler Series 9413 > Galvanic isolation between input and output ATEX Zone 0 1 2 20 21 22 Ex i interface x x x x For use in x x x x Selection Table Version Channels Input Output Order number Art. no. PS Weight kg Electronic relay Series 9174 1 Ex i Ex e, 48 V DC, 2 A 9174/10-14-00 212340 29 0.110 Ex e, 250 V UC, 1 A 9174/10-15-00 212431 29 0.110 Technical Data Explosion protection Europe (ATEX) Gas and dust applied for EII 2 G Ex e mb [ib Gb] IIC T4 Gb E II (2) D [Ex ib Db] IIIC Version 9174/10-14-10 9174/10-15-10 Safety data Max. voltage Ui 28 V 28 V Max. current Li 150 mA 150 mA Max. power Pi 780 mW 780 mW Internal capacitance Ci negligible negligible Internal inductance Li negligible negligible Isolation voltage 253 V 253 V Rated operational current Ex e back-up fuse 2 A 3.15 A Max. power dissipation 0.85 W 1.6 W Ex i input Switching level for ON / OFF ON 11 ... 28 V 11 ... 28 V OFF 0 ... 5 V 0 ... 5 V Control current < 15 mA < 15 mA Ex e output Max. voltage 48 V DC 250 V AC / DC Max. current 2 A 1 A Min. voltage 5 V DC 90 V AC / 40 V DC Min. current 2 mA 10 mA Max. switching frequency 300 Hz 300 Hz Kapitel_A3_KP00_en.book Seite 40 Dienstag, 7. Januar 2014 8:03 08
  • 43. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 412013-09-10·KP00·III·en Isolators Electronic Relay Series 9174 Dimensional Drawings (All Dimensions in mm / inch) - Subject to Alterations 14836E00 101,5 mm / 3.99 " 90mm/3.54" 108,8 mm / 4.28 " 7,5mm/0.29" 92mm/3.62" 79mm/3.11"12,2mm/0.48" Kapitel_A3_KP00_en.book Seite 41 Dienstag, 7. Januar 2014 8:03 08
  • 44. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Binary Output Series 9175 42 Isolators 2013-09-10·KP00·III·en Series 9175 A3 09822E00 WebCode 9175A > For intrinsically safe operation of I.S. solenoid valves and indicators > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use up to SIL 3 (IEC 61508) *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels No-load voltage Uout Max. output current Iout max Internal resistance Ri Order number Art. no. PS Binary output Series 9175 1 10 V 60 mA 150 Ω 9175/10-12-11s 160398 21 17.5 V 45 mA 130 Ω 9175/10-14-11s 160410 21 25 V 35 mA 250 Ω 9175/10-16-11s 160416 21 2 10 V 60 mA / 120 mA *) 150 Ω / 75 Ω *) 9175/20-12-11s 160404 21 17.5 V 45 mA / 90 mA *) 130 Ω / 65 Ω *) 9175/20-14-11s 160413 21 25 V 35 mA / 70 mA *) 250 Ω / 125 Ω *) 9175/20-16-11s 160419 21 *) Parallel connection of the outputs possible; thus, doubling of the output current. Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Kapitel_A3_KP00_en.book Seite 42 Dienstag, 7. Januar 2014 8:03 08
  • 45. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 432013-09-10·KP00·III·en Isolators Binary Output Series 9175 Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 10.0050X Ex nAc nCc [ia] IIC T4 [Ex ia] IIIC Europe (ATEX) Gas and dust DMT 03 ATEX E 043 X E II 3 (1) G Ex nA nC [ia] IIC T4 E II (1) D [Ex iaD] Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) Ship approval DNV Safety data Version 9175/.0-12-11. 9175/.0-14-11. 9175/.0-16-11. Max. values per output Max. voltage Uo 11.3 V 19.6 V 11.3 V Max. current Io 75 mA 150 / 60 mA 110 / 50 mA Max. power Po 210 mW 732 mW 760 mW Auxiliary power Nominal voltage UN 24 V DC Nominal current (at UN, Iout max) 80 mA / 140 mA Input Voltage for ON / OFF ON 15 ... 31.2 V OFF 0 ... 5 V Control circuit < 5 mA Ex i output see selection table Fault detection Ex i output Signalization of faulty line and power supply failure - Contact (30 V / 100 mA) closed to ground in case of fault - pac-Bus, floating contact (30 V / 100 mA) Kapitel_A3_KP00_en.book Seite 43 Dienstag, 7. Januar 2014 8:03 08
  • 46. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Binary Output with Line Fault Transparency Series 9175 44 Isolators 2013-09-10·KP00·III·en Series 9175 A3 07439E00 WebCode 9175A > For intrinsically safe operation of I.S. solenoid valves and indicators > Intrinsically safe output [Ex ia] IIC > Line fault transparency (LFT): line fault signalling directly via output on PLC / DCS > For use up to SIL 2 (IEC 61508) ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x x x Installation in x x Selection Table Version Channels No-load voltage Uout Max. output current Iout max Internal resistance Ri Order number Art. no. PS Binary output with line fault transparency Series 9175 1 10 V 60 mA 150 Ω 9175/10-12-12s 168456 21 17.5 V 45 mA 130 Ω 9175/10-14-12s 168458 21 25 V 35 mA 250 Ω 9175/10-16-12s 168460 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Kapitel_A3_KP00_en.book Seite 44 Dienstag, 7. Januar 2014 8:03 08
  • 47. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 452013-09-10·KP00·III·en Isolators Binary Output with Line Fault Transparency Series 9175 Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 10.0050X Ex nAc nCc [ia] IIC T4 [Ex ia] IIIC Europe (ATEX) Gas and dust DMT 03 ATEX E 043 X E II 3 (1) G Ex nA nC [ia] IIC T4 E II (1) D [Ex iaD] Certifications and certificates Certificates IECEx, ATEX, India (PESO), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR), Belarus (operating authorisation) Ship approval DNV Max. values per output Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12. Max. voltage Uo 11.3 V 19.6 V 11.3 V Max. current Io 110 / 50 mA 150 / 60 mA 75 mA Max. power Po 760 mW 732 mW 210 mW Auxiliary power Nominal voltage UN 24 V DC 24 V DC 24 V DC Current consumption Device draws its power from auxiliary power or signal cable as a function of its switching state. Version 9175/.0-16-12. 9175/.0-14-12. 9175/.0-12-12. Switching state Input = Output Input = Output Input = Output Switching state OFF Auxiliary power rated current IN 40 mA 35 mA 30 mA Switching state ON Auxiliary power rated current IN 14 mA 14 mA 14 mA Signal input rated current IN 90 mA 80 mA 50 mA Power consumption 2.5 W 2.26 W 1.5 W Power loss 1.92 W 1.73 W 1.4 W Input Voltage for ON / OFF ON 15 ... 31.2 V OFF 0 ... 5 V Control circuit < 5 mA Ex i output see selection table Fault detection Ex i output Signalization of faulty line and power supply failure - contact on the signal input open in case of fault - pac-Bus, floating contact (30 V / 100 mA) Kapitel_A3_KP00_en.book Seite 45 Dienstag, 7. Januar 2014 8:03 08
  • 48. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Binary Output without Power Supply Series 9176 46 Isolators 2013-09-10·KP00·III·en Series 9176 A3 10495E00 WebCode 9176A > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between inputs and outputs > For use up to SIL 3 (IEC 61508) *) Restrictions see table explosion protection ATEX NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels No-load voltage Uout Max. output current Iout max Internal resistance Ri Order number Art. no. PS Binary output without power supply Series 9176 1 10 V 60 mA 150 Ω 9176/10-12-00s 160452 21 17.5 V 45 mA 130 Ω 9176/10-14-00s 160459 21 25 V 29 mA 320 Ω 9176/10-15-00s 160472 21 35 mA 250 Ω 9176/10-16-00s 160465 21 43 mA 460 Ω 9176/10-17-00s 200546 21 2 10 V 60 mA / 120 mA *) 150 Ω / 75 Ω *) 9176/20-12-00s 160456 21 17.5 V 45 mA / 90 mA *) 130 Ω / 65 Ω *) 9176/20-14-00s 160462 21 25 V 29 mA / 58 mA *) 320 Ω / 160 Ω *) 9176/20-15-00s 165567 21 35 mA / 70 mA *) 250 Ω / 125 Ω *) 9176/20-16-00s 160468 21 43 mA / 86 mA *) 460 Ω / 230 Ω *) 9176/20-17-00s 171425 21 *) Parallel connection of the outputs possible. Doubling of the output current. Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Kapitel_A3_KP00_en.book Seite 46 Dienstag, 7. Januar 2014 8:03 08
  • 49. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 472013-09-10·KP00·III·en Isolators Binary Output without Power Supply Series 9176 Technical Data Explosion protection Europe (ATEX) Gas and dust BVS 04 ATEX E 075 X E II 3 (1) G Ex nA [ia] IIC T4 E II (1) D [Ex iaD] Certifications and certificates Certificates ATEX, Brazil (INMETRO), India (PESO), Canada (cFM), Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR), USA (FM), USA (UL) - not for type 9176/..-17-00, Belarus (operating authorisation) Ship approval DNV Safety data Version 9176/..-12-... 9176/..-14-... 9176/..-15-... 9176/..-16-... 9176/..-17-... Max. values per output Max. voltage Uo 11.3 V 19.6 V 27.6 V 27.6 V 27.6 V Max. current Io [Ex ia] 75 mA 150 mA 86.5 mA 110 mA 60 mA [Ex ib] – – 60 mA 44 mA 50 mA – – Max. power Po 210 mW 732 mW 596 mW 760 mW 415 mW Auxiliary power without Input Voltage for ON / OFF ON 18 ... 31.2 V OFF 0 ... 5 V Ex i output see selection table Kapitel_A3_KP00_en.book Seite 47 Dienstag, 7. Januar 2014 8:03 08
  • 50. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Resistance Isolator Series 9180 48 Isolators 2013-09-10·KP00·III·en Series 9180 A3 11026E00 WebCode 9180A > For intrinsically safe operartion of resistance thermometers or other resistance sensors > World-wide unique dual channel solution – space saving, only 8.8 mm per channel > For 2-, 3- and 4-wire circuits > Resistance range from 18 ... 391 Ω or 180 ... 3910 Ω > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Measuring range Order number Art. no. PS Resistance isolator Series 9180 1 18 ... 391 Ω (Pt100) 9180/10-77-11s 160491 21 180 ... 3910 Ω (Pt1000) 9180/11-77-11s 160499 21 2 18 ... 391 Ω (Pt100) 9180/20-77-11s 160494 21 180 ... 3910 Ω (Pt1000) 9180/21-77-11s 160502 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Technical Data Explosion protection Global (IECEx) Gas and dust IECEx BVS 10.0055X Ex nAc nCc [ia] IIC T4 [Ex ia] IIIC Europe (ATEX) Gas and dust BVS 05 ATEX E 176 X E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC Certifications and certificates Version 9180/.0 9180/.1 Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (GOST K), Korea (KCs) only for 9180/10-77-11., Russia (GOST R), USA (FM), Belarus (operating authorisation) IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (GOST K), Russia (GOST R), USA (FM), Belarus (operating authorisation) Ship approval DNV DNV Kapitel_A3_KP00_en.book Seite 48 Dienstag, 7. Januar 2014 8:03 08
  • 51. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 492013-09-10·KP00·III·en Isolators Resistance Isolator Series 9180 Version 9180/.0 9180/.1 Safety data Max. voltage Uo 6.5 V 6.5 V Max. current Io 16.5 mA 16.5 mA Max. power Po 27 mW 27 mW Ex i input Connection type (no. of wires) 2-, 3-, 4-wire circuits 2-, 3-, 4-wire circuits Measuring range 18 ... 391 Ω (Pt100) 180 ... 3910 Ω (Pt1000) Middle resolution 10 m Ω 100 m Ω Output Output signal equals input signal (resistance) Response time (10 ... 90 %) Multiplexer operation < 10 ms Response time (Input = Output) < 1sec Error detection Ex i input Message of line fault and auxiliary power failure - contact (30 V / 100 mA) closed to earth in case of error - pac-Bus, potential-free contact (30 V / 100 mA) Technical Data 9180_ResistanceIsolator_KP00_IIII_en.fm Seite 49 Donnerstag, 16. Januar 2014 8:16 08
  • 52. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Temperature Transmitter Field Circuit Ex i Series 9182 50 Isolators 2013-09-10·KP00·III·en Series 9182 A3 09746E00 WebCode 9182A > For intrinsically safe operation of thermocouples, resistance thermometers, resistance transmitters, mV-sources > One unit individually configurable for nearly all temperature sensors > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output, power supply and configuration interface > Open-circuit and short-circuit monitoring and messaging (can be switched off) > Simple configuration with PC or DIP-switches *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Output Limit value contact (per channel) SIL Order number Art. no. PS Temperature transmitter Series 9182, field circuit Ex i 1 0/4 ... 20 mA active / source without – – 9182/10-51-11s 160546 21 2 9182/10-51-13s 201653 21 2 NO / NC – – 9182/10-51-12s 160549 21 2 9182/10-51-14s 201682 21 0/4 ... 20 mA passive / sink without 2 9182/10-59-13s 201657 21 2 0/4 ... 20 mA active / source without – – 9182/20-51-11s 160541 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Signal duplication due to parallel connection of inputs of 9182/20-51-.. (dual channel). Further information see operating instruction. Kapitel_A3_KP00_en.book Seite 50 Dienstag, 7. Januar 2014 8:03 08
  • 53. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 512013-09-10·KP00·III·en Isolators Temperature Transmitter Field Circuit Ex i Series 9182 Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 09.0046X Ex nAc nCc [ia] IIC T4 [Ex ia] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E 243 X E II 3 (1) G Ex nAc nCc [ia] IIC T4 E II (1) D [Ex ia] IIIC Certifications and certificates Version 9182/.0-51-1. 9182/10-5.-13, SIL 2 9182/10-51-14, SIL 2 Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KTL) only for 9182/10-51-11, Russia (GOST R), Ukraine (TR), USA (FM, UL), Belarus (operating authorisation) IECEx, ATEX, Kazakhstan (GOST K), Russia (GOST R), Ukraine (TR), Belarus (operating athorisation) Ship approval DNV DNV Safety data Max. voltage Uo 6.5 V Max. current Io 19.7 mA Max. power Po 32 mW (linear characteristic) Auxiliary power Nominal voltage UN 24 V DC Nominal current at UN 1 channel 70 mA 2 channels 80 mA Ex i Input The input parameters can be set via the parameterising software ISpac Wizard or DIP switch (only type 9182/.0-5.-11.). Input resistance thermometer Type of circuit 2-, 3-, 4-wire circuit Input thermocouple Types B, E, J, K, N, R, S, T, L, U, XK Input resistance transmitter (RTD) up to 100 k Ω Output (only for 9182/.0-51-1.) Output signal 0/4 ... 20 mA (configurable) Connectable load resistance RL 1 channel 0 ... 750 Ω 2 channels 0 ... 600 Ω Limiting values Message 2 NO / NC per channel (configurable using ISpac Wizard) Switching voltage ( ± 30 V Switching current (resistive load) ( 100 mA Error detection Ex i input Message of line fault and auxiliary power failure - contact (30 V / 100 mA) closed to earth in case of error - pac-Bus, potential-free contact (30 V / 100 mA) Types Pt 100, Pt 500, Pt 1000 Ni 100, Ni 500, Ni 1000 9182_xx-xx-1x_TemperatureTransmitter_KP00_III_en.fm Seite 51 Donnerstag, 16. Januar 2014 8:20 08
  • 54. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Fieldbus Isolating Repeater Series 9185 52 Isolators 2013-09-10·KP00·III·en Series 9185 A3 09812E00 WebCode 9185A > For isolation between an intrinsically safe or non-intrinsically safe RS 422 / RS 485 bus and a non-intrinsically safe RS 232, RS 422, RS 485 interface > For operation of the intrinsically safe Profibus DP (RS 485 IS to PNO standard) > Intrinsically safe fieldbus RS 422, RS 485 [Ex ib] IIC > Galvanic isolation between RS 422 / RS 485 (Ex i), RS 232, RS 422, RS 485 and power supply > Transmission speed adjustable between 1.2 kbit/s and 1.5 Mbit/s > Automatic setting of transmission speed for Profibus DP > Bitrefresh *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x Ex i interface x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Interfaces field area Interfaces safe area Order number Art. no. PS Fieldbus isolating repeater Series 9185 RS-485 IS (PNO) RS-232, RS-422, RS-485 9185/11-35-10s 160587 21 RS-422, RS-485 RS-232, RS-422, RS-485 9185/12-45-10s 160594 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Kapitel_A3_KP00_en.book Seite 52 Dienstag, 7. Januar 2014 8:03 08
  • 55. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 532013-09-10·KP00·III·en Isolators Fieldbus Isolating Repeater Series 9185 Technical Data Version 9185/11-35-10 9185/12-45-10 Explosion protection Global (IECEx) Gas and dust IECEx BVS 06.0004X IECEx BVS 06.0004X Ex nAc [ib] IIC T4 [Ex ib] IIIC Ex nAc IIC T4 Europe (ATEX) Gas and dust DMT 02 ATEX E246X BVS 10 ATEX E 105 X E II (2) GD [EEx ib] IIC/IIB, E II 3 G EEx nA II T4 E II 3G Ex nAc IIC T4 Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM), Belarus (operating authorisation) IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), Serbia (SRPS), Ukraine (TR), USA (FM), Belarus (operating authorisation) Ship approval DNV, ABS, RS DNV, ABS, RS Version 9185/11-35-10 9185/12-45-10 Safety data Max. voltage Uo 3.73 V – – Max. current Io 149 mA – – Max. power Po 139 mW – – For connection RS 485 IS Insulation voltage 253 V – – Internal capacity Ci and inductivity Li negligible – – Max. permissible voltage Ui ± 4.2 V – – Auxiliary power Nominal voltage UN 24 V UC 24 V UC Nominal current (24 V) 80 mA 80 mA Interface field area Version RS 485 IS RS 485 / RS 422 (can be set) Level setting: RS 485 IS (PNO specification) and RS 485 IS (R. STAHL specification) EIA RS 485, EIA RS 422 Connections Sub-D socket X3, 9-pole Sub-D socket X3, 9-pole Transfer speed 1.2 kbit/s ... 1.5 Мbit/s 1.2 kbit/s ... 1.5 Мbit/s Settings fixes transmission speed or automatic detection > 9.6 kbit/s (only with Profibus DP) fixes transmission speed or automatic detection > 9.6 kbit/s (only with Profibus DP) Line length depends on transmission speed and cable depends on transmission speed and cable Terminating resistor to be set in external plug to be set in external plug Data transmission indication LED green "RxD3" LED green "RxD3" Interface safe area Version RS 232, RS 422 (from Rev. B), RS 485 RS 232, RS 485 / RS 422 (can be set) Settings fixed transmission speed or automatic detection > 9.6 kbit/s (only with Profibus DP) fixed transmission speed or automatic detection > 9.6 kbit/s (only with Profibus DP) Kapitel_A3_KP00_en.book Seite 53 Dienstag, 7. Januar 2014 8:03 08
  • 56. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Fibre Optics Fieldbus Isolating Repeater Series 9186 54 Isolators 2013-09-10·KP00·III·en Series 9186 A3 08579E00 WebCode 9186A > Easy installation and mainetance due to: – Intrinsically safe optical interface – Intrinsically safe bus connection via RS-485 IS (PNO) > High availability due to: – Build-up of ring structures, redundant Point-to-Point, line structures – Integrated analysis of optical input signal – Error message if critical levels of input signal reached > Transmission of Profibus DP, Modbus, HART on RS-485, R. STAHL Servicebus > 9186/12 – Installation in Zone 1 and Zone 2 possible – Fieldbus interface for intrinsically safe Profibus DP (PNO) > 9186/.5 – Installation in Zone 2 possible *) Restrictions see table explosion protection ATEX NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 0 1 2 20 21 22 Division 1 2 1 2 1 2 9186/12-11-11: Ex i interface x x x x x x x x x 9186/12-11-11: Ex i interface x x x x x x 9186/.5-..-..: Ex i interface x x x 9186/.5-..-..: Ex i interface x x x 9186/12-11-11: Installation in x*) x*) x*) x*) x*) x*) x*) 9186/12-11-11: Installation in x*) x*) x*) 9186/.5-..-..: Installation in x*) x*) x*) x*) 9186/.5-..-..: Installation in x*) x*) x*) Selection Table Version Installation in Network structure Order number Art. no. PS Fibre optics fieldbus isolating repeater Series 9186 Zone 1 Ring, point-to-point redundant, line 9186/12-11-11 160623 25 Zone 2 and in the safe area Point-to-point, end of line 9186/25-12-11 160625 25 Ring, point-to-point redundant, line 9186/15-12-11 160624 25 Technical Data Version 9186/12 9186/.5 Installation in Zone 1 Zone 2 and in the safe area Explosion protection Europe (ATEX) Gas and dust BVS 06 ATEX E 145 X BVS 07 ATEX 068 X E II 2G (1) G Ex e mb ib [ia, op is] IIC T4 E II (1) D [Ex iaD] E II (1) GD [Ex op is] IIC E II 3 G Ex nA nC II T4 Certifications and certificates Certificates ATEX, Kazakhstan (GOST K), Russia (GOST R), USA (FM) ATEX, Canada (UL), Kazakhstan (GOST K), Russia (GOST R), USA (UL) Ship approval DNV DNV Safety data Max. voltage Uo ± 3.7 V – – Max. current Io 148 mA – – Max. power Po 137 mW – – Kapitel_A3_KP00_en.book Seite 54 Dienstag, 7. Januar 2014 8:03 08
  • 57. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 552013-09-10·KP00·III·en Isolators Fibre Optics Fieldbus Isolating Repeater Series 9186 Version 9186/12 9186/.5 Installation in Zone 1 Zone 2 and in the safe area Safety data For connection RS 485 IS Max. permissible voltage Ui ± 4.2 V – – Internal capacity Ci and inductivity Li negligible – – Ex i fault-contact Max. permissible voltage Ui 24 V – – Max. permissible current Ii 600 mA – – Internal capacity Ci and inductivity Li negligible – – Auxiliary power Nominal voltage UN 24 V DC 24 V DC Nominal current (at UN) 67 mA 130 mA Optical interface Protocols protocol transparent for RS-485 interface protocol transparent for RS-485 interface Network topologies Ring topology, line topology, point-to-point connection Ring topology, line topology, point-to-point connection Redundancy automatic switching in case of line fault automatic switching in case of line fault Connection ST®, BFOC/2.5 connector ST®, BFOC/2.5 connector Wavelength 850 nm 850 nm Transmission distance ( 2000 m ( 2000 m Electrical interfaces Protocols PROFIBUS DP, Modbus, HART, ServiceBus R.STAHL (IS1) PROFIBUS DP, Modbus, HART, ServiceBus R.STAHL (IS1) Version RS 485 IS (PNO) RS 485 Connection Sub-D socket X1, 9-pole Sub-D socket X1, 9-pole Bit rate 1.2 kbit/s ... 1.5 Mbit/s 9.6 kbit/s ... 1.5 Mbit/s Fault control Power supply failure Fault-contact is open Fault-contact is open Transmission level is good LED green and yellow "FO signal", fault-contact is closed LED green and yellow "FO signal", fault-contact is closed Transmission level reduced (- 1.5 dBm) LED yellow "FO signal", fault-contact is open LED yellow "FO signal", fault-contact is open Fibre breakage or transmission level is too low (- 3 dBm) LED red "FO ERR", fault-contact is open LED red "FO ERR", fault-contact is open Switching capacity of fault-contact see Ex i values max. 60 V DC, 42 V, 1 A Mechanical data Weight approx. 200 g approx. 200 g Mounting type on DIN rail, EN 50022 (NS35/15; NS35/7.5) on DIN rail, EN 50022 (NS35/15; NS35/7.5) Technical Data Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 06251E00 11335E00 11328E00 9186/12-11-11 9186/15-12-11 9186/25-12-11 126,5mm/4.98" 119mm/4.68" 99 mm / 3.89 " 106 mm / 4.17 " 35,2 mm 1.38 " 99 mm / 3.89 " 106 mm / 4.17 " 35,2 mm 1.38 " 114,2mm/4.49" 106,7mm/4.20" 99 mm / 3.89 " 106 mm / 4.17 " 35,2 mm 1.38 " 114,2mm/4.49" 106,7mm/4.20" Kapitel_A3_KP00_en.book Seite 55 Dienstag, 7. Januar 2014 8:03 08
  • 58. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 HART-Multiplexer Series 9192 56 Isolators 2013-09-10·KP00·III·en Series 9192 A3 09730E00 WebCode 9192A > Used for connection of up to 32 HART capable field devices to an HART management system > Compatible to Cornerstone, AMS, FDM, Fieldcare, PDM, PRM etc. and FDT application > CommDTM for integration into FDT tools > Up to 128 HART-Multiplexer on one PC interface > Up to 3968 HART field devices > Galvanic isolation between power supply, RS 485 bus and HART channels > For use up to SIL 3 (IEC 61508) *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Channels Order number Art. no. PS HART-Multiplexer Series 9192 32 9192/32-10-10 160695 21 incl. 14-core connection cable for pac-Carrier Series 9195 or HART connection board Series 9196 CommDTM available, download under the given WebCode 9192A Kapitel_A3_KP00_en.book Seite 56 Dienstag, 7. Januar 2014 8:03 08
  • 59. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 572013-09-10·KP00·III·en Isolators HART-Multiplexer Series 9192 Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 10.0042X Ex nAc II T4 Europe (ATEX) Gas BVS 03 E 213 X E II 3 G Ex nA II T4 Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), USA (FM), Belarus (operating authorisation) Ship approval DNV Auxiliary power Nominal voltage UN 24 V DC Nominal current (24 V) 55 mA System configuration 09237E00 Field device interface (HART) Number of channels 16 or 32, setting via switch Connection Ribbon cable, 14-pole (inclusive) Signal HART FSK HART Specification HART Field Communication Protocal Rev. 7.1 (downwards compatible to Rev. 4.0); FSK Physical Layer Specification (Rev. 7.1) RS 485 interface Number 1 Connection Sub-D socket, 9-pole Signal RS 485 Protocol compatible to Cornerstone, AMS, PDM, PRM, FDM Number of HART- Multiplexer per bus segment maximum 31 Kapitel_A3_KP00_en.book Seite 57 Dienstag, 7. Januar 2014 8:03 08
  • 60. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 Supply Module Series 9193 58 Isolators 2013-09-10·KP00·III·en Series 9193 A3 09814E00 WebCode 9193A > Supply of 24 V DC power supply into the pac-Bus > Supply current up to 4 A (for approx. 30 - 50 modules) > Single or redundant supply, decoupled via diodes, with LED indication > Exchangeable fuses for both supply circuits > Power supply failure and line fault messaging via relay contacts > Different operating modes can be selected via DIP-switches (error signal and single / redundant supply) > Any installation on the pac-Bus (beginning, end, middle, both sides) *) Restrictions see table explosion protection ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Supply Error messaging Order number Art. no. PS Supply module Series 9193 24 V / 4 A, primary + redundant Line fault and power supply failure 9193/20-11-11s 160717 21 Note The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. Kapitel_A3_KP00_en.book Seite 58 Dienstag, 7. Januar 2014 8:03 08
  • 61. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 592013-09-10·KP00·III·en Isolators Supply Module Series 9193 Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 10.0042X Ex nAc nCc II T4 Europe (ATEX) Gas BVS 03 E 213 X E II 3 G Ex nA nC II T4 Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Korea (KCs), Russia (GOST R), USA (FM) Ship approval DNV Input Power supply 24 V DC Input range 18 ... 31.2 V Redundant supply yes, decoupled with diodes Safety fuse 5 x 20 mm; 2 x T 4.0 A; exchangeable for prim. and red. supply Output Supply into the pac-Bus 24 V / maximum 4 A Error message Power fail PF Contact (35 V / 100 mA) Line fault LF Contact (35 V / 100 mA), closed in good conditions Kapitel_A3_KP00_en.book Seite 59 Dienstag, 7. Januar 2014 8:03 08
  • 62. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 pac-Bus Series 9194 60 Isolators 2013-09-10·KP00·III·en Series 9194 A3 02710E00 WebCode 9194A > Supply for approx. 40 modules per segment > Usabel for high and low profile DIN rails (NS35/15 and NS35/7.5) > Just snap on DIN rail without tools > Elements can be appended at any time > Potential free error messaging contact for common error signal > Gold plated contacts for highest contact safety > Low cost supply via terminals > Supply module with integrated replaceable fuses and redundant supply available *) Restrictions see table explosion protection: ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Picture Description Order number Art. no. PS pac-Bus Series 9194 09885E00 pac-Bus single element, raster distance 17.6mm 9194/31-17 160731 21 Terminal set for pac-Bus 10374E00 5-pole, (set begin + end) with bridge for error message chain 9194/50-01 160730 21 Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 10.0042X Ex nAc II T4 Europe (ATEX) Gas BVS 03 E 213 X E II 3 G Ex nA II T4 Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), USA (FM) Ship approval DNV Auxiliary power Max. current 4 A Connection Screw terminals, 5-pole, maximum 1.5 mm2 or via supply module Series 9193 Mounting type on DIN-rail Mounting orientation horizontal or vertical Kapitel_A3_KP00_en.book Seite 60 Dienstag, 7. Januar 2014 8:03 08
  • 63. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 612013-09-10·KP00·III·en Isolators pac-Bus Series 9194 Dimensional Drawing (All Dimensions in mm / inches) - Subject to Alterations 09858E00 3,8 mm / 0.15 " 24,2 mm / 0.95 " 17,6 mm / 0.69 " 22 mm / 0.87 " 37 mm / 1.45 " 15mm/0.59" 21mm/0.82" Kapitel_A3_KP00_en.book Seite 61 Dienstag, 7. Januar 2014 8:03 08
  • 64. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 pac-Carrier Series 9195 62 Isolators 2013-09-10·KP00·III·en Series 9195 A3 14224E00 WebCode 9195A > pac-Carrier for 8 or 16 modules, up to 32 signals > All standard ISpac isolators can be used > Integration of Ex i and non-Ex i field circuits in one carrier > Flexible engineering due to: – direct allocation between I/O module and pac-Carrier – simple connection to the HART managemet system – horizontal and vertical installation possible – installation possible in Zone 2 and Div. 2 > Easy and quick installation due to: – customized system cables to automation system – installation of the isolators without tools – installation of the carrier on DIN rail or mounting plate > Low out of service time of the system due to: – redundant power supply with fault detection contact and exchangeable fuses – very robust chassis proven by the DNV approval for ship building *) Restrictions see table explosion protection: ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x*) x*) Installation in x*) x*) Installation in x*) x*) x*) Selection Table Version Number of slots Connection HART-Multiplexer Order number PS pac-Carrier Series 9195 8 no 9195/08A-...-... 27 9192/32 9195/08H-...-... 27 16 no 9195/16A-...-... 27 9192/32 9195/16H-...-... 27 Customer specific versions for the following DCS: Yokogawa Centum VP, Yokogawa Pro-Safe-RS, Emerson Delta V, TRICONEX, Invensys, Honeywell, Siemens. Detailed information about the available pac carrier versions as well as technical documentation you may download from the internet at www.ispac.info. Engineering and shipment of new versions within 6 weeks. Technical Data Explosion protection Global (IECEx) Gas IECEx BVS 10.0042X Ex nAc nCc II T4 Europe (ATEX) Gas BVS 03 ATEX E 213 X E II 3 G Ex nA nC II T4 Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Canada (CSA), Kazakhstan (GOST K), Russia (GOST R), USA (FM) 9195_pac-Carrier_KP00_III_en.fm Seite 62 Donnerstag, 16. Januar 2014 8:57 08
  • 65. A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 A3 632013-09-10·KP00·III·en Isolators pac-Carrier Series 9195 Auxiliary power Nominal voltage UN 24 V DC Redundant supply yes, decoupled with diodes Fuse 2 x TR5; T 2.0 A; exchangeable, for primary and redundant supply Connection of field devices Number of channels 8, 16, 32 System configuration 10154E02 HART interface Connection - via connection of automation systems - via HART multiplexer 9192 (only at 9195/..H-...-...) Error message Power fail PF Contact (35 V / 100 mA), closed in good conditions Technical Data i p Ex i PLC or DCS Asset Management System System cableSystem cable redundant HART RS485 HART Mux pac Carrier 9195 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 09826E00 Type 9195/08.-...-..., 8 slots 09854E00 Type 9195/16.-...-..., 16 slots * depending on Type, see Engineering Guide 155mm/6.10" 130mm/5.12" 144 mm / 5.67 " 1 0 mm 5. "3 / 12/ 1 0 mm 5. "5 / 91/ * * 155mm/6.10" 130mm/5.12" 286 mm / 11.26 " 1 0 mm 5. "3 / 12/ 1 0 mm 5. "5 / 91/ * * 9195_pac-Carrier_KP00_III_en.fm Seite 63 Donnerstag, 16. Januar 2014 8:57 08