SlideShare a Scribd company logo
V-1
FEED
TANK
V-2
SURGE
TANK
E-1
HEATER
E-2
COOLER
1B
HS
1
LV 1
LY
I/P
1"
FC
LRC
1
LY
1
LRC
1
HS
1A
P/I
2" NC
1"
1" NC
2"
3/4" NC
DCS
2" 2"
1 1/2" NC
5
LG
1"
NC 2"
2"
1" NC
1
LT
1"
NC2"
2"
1"
NC
V-1
2"2"
1" NC
2"
NC
2" 2"
2"
2"
PI
3/4" 3/4" 3/4"
NC NC NC 1"
2"
3/4" NC
NC
2
FT
2
HS
FRC
2A
2B
FY
P/I
FRC
2B
DCS
HS
2
FY
2B
2"
NC
2
FV
1"
2" 2"
3/4"
NC
3/4"
NC
2" 2"
1 1/2" NC
6
LG
1"
NC 2"
2"
1" NC
6
LT
1"2"
2"
1"
NC
V-2
2"
2"
1" NC
2"
P-1
FEED PUMP
30 GPM
3 HP 1730 RPM
2" NC
3/4"
NC
2"
2"
3/4" NC
1 1/2"
1"
P-3
SPARE PUMP
30 GPM
3 HP 1730 RPM
PI
3/4"3/4"
NCNC
2"
NC
2"
NC
2"
2"
2"
3/4" NC
2"
P-2
RECIRC PUMP
30 GPM
3 HP 1730 RPM
NC
PI
3/4"
3/4"
NC
NC1"
3/4"
2"
NC
9
FT
9A
HS
9
FY
9
FY
FRC
9
DCS
FRC
9
9
FY
P/I
P/I
P/I
DCS
FRC
9
9B
HS
3/4"
3"
2" Sch 40 C.S. (Typical)
2"
NC
3/4"
2"
3"
E-1 (K)
TI
14
TT
15
TT
2"
E-2 (M)
2"
3/4"
NC
2"
2"
TI
14
DCS
TI
15
DCS 1"
2" 2"
3/4"
NC
3/4"
NC
NC
2"
FC
16
TT
TI
16
DCS
Chilled Water Return
Chilled Water Supply
2"
2"
Hot Water Return
2" Ins.
19
FV
1"
2"
3/4"
NC
3/4"
NC
NC
2"
FC
9
FV
2"
1"
2"
3/4"
NC
3/4"
NC2"
FC
2"2" Ins.
3/4"
NC
2"
13
TT
FRC
18
DCS
17
TV
18
HS
18
TY
I/P
TI
13
DCS
FRC
18 18
HS
18
FY
P/I
18
FT
Hot Water Supply
11
TT
TI
11
DCS
19A
HS
19
FY
I/P
FRC
19
DCS
FRC
19 19B
HS
19
FY
P/I
19
FT
LEGEND
Gate Valve
Check Valve
Normally Closed ValveNC
I/P
NC
FC
NC
PROCESS TRAINING FACILITY
DRAWN BY: RAMONA L. TATESCALE: 3:4 05-06-2015 SHEET 1 OF 1
LAMAR INSTITUTE OF TECHNOLOGY DFTG 2308

More Related Content

Viewers also liked

P12-11
P12-11P12-11
LOOP DIAGRAM 09L308-Size B
LOOP DIAGRAM 09L308-Size BLOOP DIAGRAM 09L308-Size B
LOOP DIAGRAM 09L308-Size B
Ramona Van Slyke
 
Blackout Avoidance & Undervoltage Load Shedding
Blackout Avoidance & Undervoltage Load SheddingBlackout Avoidance & Undervoltage Load Shedding
Blackout Avoidance & Undervoltage Load Shedding
michaeljmack
 
auto matic load shedding control for substation
auto matic load shedding control for substationauto matic load shedding control for substation
auto matic load shedding control for substation
bishow kandel
 
Engineering As Carrier Option
Engineering As Carrier OptionEngineering As Carrier Option
Engineering As Carrier Option
Vinodrai Engineers P Ltd.,
 
Effects of load shedding in pakistan
Effects of load shedding in pakistanEffects of load shedding in pakistan
Effects of load shedding in pakistan
nabeeloutlaw
 
6 things you should know about industrial engineering
6 things you should know about industrial engineering6 things you should know about industrial engineering
6 things you should know about industrial engineering
IE Saeed Shurrab
 

Viewers also liked (7)

P12-11
P12-11P12-11
P12-11
 
LOOP DIAGRAM 09L308-Size B
LOOP DIAGRAM 09L308-Size BLOOP DIAGRAM 09L308-Size B
LOOP DIAGRAM 09L308-Size B
 
Blackout Avoidance & Undervoltage Load Shedding
Blackout Avoidance & Undervoltage Load SheddingBlackout Avoidance & Undervoltage Load Shedding
Blackout Avoidance & Undervoltage Load Shedding
 
auto matic load shedding control for substation
auto matic load shedding control for substationauto matic load shedding control for substation
auto matic load shedding control for substation
 
Engineering As Carrier Option
Engineering As Carrier OptionEngineering As Carrier Option
Engineering As Carrier Option
 
Effects of load shedding in pakistan
Effects of load shedding in pakistanEffects of load shedding in pakistan
Effects of load shedding in pakistan
 
6 things you should know about industrial engineering
6 things you should know about industrial engineering6 things you should know about industrial engineering
6 things you should know about industrial engineering
 

Similar to PROCESS TRAINING FACILITY

Fabrication drawings
Fabrication drawingsFabrication drawings
Fabrication drawings
Dongze Di
 
WIRING DIAGRAM MAZDA 3 2018.pdf
WIRING DIAGRAM MAZDA 3 2018.pdfWIRING DIAGRAM MAZDA 3 2018.pdf
WIRING DIAGRAM MAZDA 3 2018.pdf
Autorepairdiagnostic
 
Catalogo industrial-gates (3)
Catalogo industrial-gates (3)Catalogo industrial-gates (3)
Catalogo industrial-gates (3)
thi sac thi sac
 
700-1810-100 D.PDF
700-1810-100       D.PDF700-1810-100       D.PDF
700-1810-100 D.PDF
A. Ovidiu "Ovy" Lungu
 
Diagrama cummins
Diagrama cumminsDiagrama cummins
Diagrama cummins
Miguel Angel Santos Pintado
 
Haiti hydropower potential-Appendix-E-1
Haiti hydropower potential-Appendix-E-1Haiti hydropower potential-Appendix-E-1
Haiti hydropower potential-Appendix-E-1
Francis Mitchell
 
Hakko 936 schematic
Hakko 936 schematicHakko 936 schematic
Hakko 936 schematic
Iman Teguh Pribadi
 
Carga muerta
Carga muertaCarga muerta
Carga muerta
anthony martinez luna
 
Chicago Med Portfolio
Chicago Med PortfolioChicago Med Portfolio
Chicago Med Portfolio
Juan Bautista
 

Similar to PROCESS TRAINING FACILITY (9)

Fabrication drawings
Fabrication drawingsFabrication drawings
Fabrication drawings
 
WIRING DIAGRAM MAZDA 3 2018.pdf
WIRING DIAGRAM MAZDA 3 2018.pdfWIRING DIAGRAM MAZDA 3 2018.pdf
WIRING DIAGRAM MAZDA 3 2018.pdf
 
Catalogo industrial-gates (3)
Catalogo industrial-gates (3)Catalogo industrial-gates (3)
Catalogo industrial-gates (3)
 
700-1810-100 D.PDF
700-1810-100       D.PDF700-1810-100       D.PDF
700-1810-100 D.PDF
 
Diagrama cummins
Diagrama cumminsDiagrama cummins
Diagrama cummins
 
Haiti hydropower potential-Appendix-E-1
Haiti hydropower potential-Appendix-E-1Haiti hydropower potential-Appendix-E-1
Haiti hydropower potential-Appendix-E-1
 
Hakko 936 schematic
Hakko 936 schematicHakko 936 schematic
Hakko 936 schematic
 
Carga muerta
Carga muertaCarga muerta
Carga muerta
 
Chicago Med Portfolio
Chicago Med PortfolioChicago Med Portfolio
Chicago Med Portfolio
 

PROCESS TRAINING FACILITY

  • 1. V-1 FEED TANK V-2 SURGE TANK E-1 HEATER E-2 COOLER 1B HS 1 LV 1 LY I/P 1" FC LRC 1 LY 1 LRC 1 HS 1A P/I 2" NC 1" 1" NC 2" 3/4" NC DCS 2" 2" 1 1/2" NC 5 LG 1" NC 2" 2" 1" NC 1 LT 1" NC2" 2" 1" NC V-1 2"2" 1" NC 2" NC 2" 2" 2" 2" PI 3/4" 3/4" 3/4" NC NC NC 1" 2" 3/4" NC NC 2 FT 2 HS FRC 2A 2B FY P/I FRC 2B DCS HS 2 FY 2B 2" NC 2 FV 1" 2" 2" 3/4" NC 3/4" NC 2" 2" 1 1/2" NC 6 LG 1" NC 2" 2" 1" NC 6 LT 1"2" 2" 1" NC V-2 2" 2" 1" NC 2" P-1 FEED PUMP 30 GPM 3 HP 1730 RPM 2" NC 3/4" NC 2" 2" 3/4" NC 1 1/2" 1" P-3 SPARE PUMP 30 GPM 3 HP 1730 RPM PI 3/4"3/4" NCNC 2" NC 2" NC 2" 2" 2" 3/4" NC 2" P-2 RECIRC PUMP 30 GPM 3 HP 1730 RPM NC PI 3/4" 3/4" NC NC1" 3/4" 2" NC 9 FT 9A HS 9 FY 9 FY FRC 9 DCS FRC 9 9 FY P/I P/I P/I DCS FRC 9 9B HS 3/4" 3" 2" Sch 40 C.S. (Typical) 2" NC 3/4" 2" 3" E-1 (K) TI 14 TT 15 TT 2" E-2 (M) 2" 3/4" NC 2" 2" TI 14 DCS TI 15 DCS 1" 2" 2" 3/4" NC 3/4" NC NC 2" FC 16 TT TI 16 DCS Chilled Water Return Chilled Water Supply 2" 2" Hot Water Return 2" Ins. 19 FV 1" 2" 3/4" NC 3/4" NC NC 2" FC 9 FV 2" 1" 2" 3/4" NC 3/4" NC2" FC 2"2" Ins. 3/4" NC 2" 13 TT FRC 18 DCS 17 TV 18 HS 18 TY I/P TI 13 DCS FRC 18 18 HS 18 FY P/I 18 FT Hot Water Supply 11 TT TI 11 DCS 19A HS 19 FY I/P FRC 19 DCS FRC 19 19B HS 19 FY P/I 19 FT LEGEND Gate Valve Check Valve Normally Closed ValveNC I/P NC FC NC PROCESS TRAINING FACILITY DRAWN BY: RAMONA L. TATESCALE: 3:4 05-06-2015 SHEET 1 OF 1 LAMAR INSTITUTE OF TECHNOLOGY DFTG 2308