This 4-page test report from SGS Taiwan Ltd summarizes the results of chemical analysis of a sample submitted by Rising Trading Co., Ltd. The report tested for levels of perfluorooctane sulfonates (PFOS) and perfluorooctanoic acid (PFOA) in a transparent liquid sample. Both PFOS and PFOA levels were below the method detection limit of 10 mg/kg. The report provides details on sample description, test methods, results, notes, and reference information on PFOS restrictions.
This 4-page test report from SGS Taiwan Ltd summarizes the results of chemical testing of a varnish sample submitted by Rising Trading Co., Ltd. The report found non-detectable levels of perfluorooctane sulfonates and perfluorooctanoic acid in the transparent liquid part of the sample. Testing was performed using US EPA methods and involved sample extraction, concentration/dilution, and analysis by liquid chromatography-mass spectrometry.
This test report from SGS Taiwan Ltd presents the results of tests conducted on a sample of size (paint) submitted by Rising Trading Co., Ltd. The tests were conducted to analyze if the sample contained regulated substances like cadmium, lead, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers. The test results showed that the concentrations of all regulated substances tested were below the method detection limits.
This document is a test report from SGS Taiwan Ltd. that analyzes a sample of varnish (Sample Description: VARNISH, Style/Item No.: F53-800BNF) submitted by Rising Trading Co., Ltd. The report details the results of testing for regulated substances like cadmium, lead, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs) according to IEC 62321. The test results were all negative, with levels of regulated substances below the method detection limit.
The document summarizes the results of testing to identify extractables and leachables from a nylon syringe filter. Multiple analytical techniques were used, identifying several oligomers of nylon 6 in leachables and additional compounds like methyl esters, glycerol esters, and alkanes in exhaustive extracts. The major polymer antioxidant Irgafos 168 was also detected.
21 quantitative lc-msms analysis of 15 estrogens and estrogen metabolites in ...CPSA-2012_5-Minutes-Fame
Primera Analytical Solutions Corp. is an analytical chemistry contract research organization founded in 2002 that offers pharmaceutical and biotech companies a range of analytical services including GMP analytical testing, method development and validation, stability testing, bioanalysis of clinical samples, preformulation, and protein characterization. It has a team of PhD scientists, robust SOPs and quality systems, ICH-compliant stability chambers, and was FDA audited in 2008 and 2012 with no observations.
Intrapersonal intelligence refers to one's awareness and understanding of oneself, according to Howard Gardner's theory of multiple intelligences. Gardner proposed that people possess different types of intelligence and may be particularly strong in some types and weak in others. Those with high intrapersonal intelligence have a clear understanding of themselves and what they need in different settings. They tend to be self-reflective, perfectionistic, and prefer working alone. While they can lack interpersonal skills, developing these abilities through group work is important to prevent isolation. A lack of intrapersonal intelligence may contribute to inconsistent choices and failure to develop life goals.
This two-page test report from SGS Testing Korea Co., Ltd summarizes the results of testing samples of NEW MDK K INK BASE submitted by SAMYOUNG INK & PAINT MFG CO., LTD. The samples were tested for levels of perfluorooctanoic acid and perfluorooctane sulfonates and found to be not detected above the method detection limit of 1 mg/kg for both substances. The report provides details of the testing performed, samples analyzed, test methods used, and results obtained.
This 4-page test report from SGS Taiwan Ltd summarizes the results of chemical testing of a varnish sample submitted by Rising Trading Co., Ltd. The report found non-detectable levels of perfluorooctane sulfonates and perfluorooctanoic acid in the transparent liquid part of the sample. Testing was performed using US EPA methods and involved sample extraction, concentration/dilution, and analysis by liquid chromatography-mass spectrometry.
This test report from SGS Taiwan Ltd presents the results of tests conducted on a sample of size (paint) submitted by Rising Trading Co., Ltd. The tests were conducted to analyze if the sample contained regulated substances like cadmium, lead, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers. The test results showed that the concentrations of all regulated substances tested were below the method detection limits.
This document is a test report from SGS Taiwan Ltd. that analyzes a sample of varnish (Sample Description: VARNISH, Style/Item No.: F53-800BNF) submitted by Rising Trading Co., Ltd. The report details the results of testing for regulated substances like cadmium, lead, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs) according to IEC 62321. The test results were all negative, with levels of regulated substances below the method detection limit.
The document summarizes the results of testing to identify extractables and leachables from a nylon syringe filter. Multiple analytical techniques were used, identifying several oligomers of nylon 6 in leachables and additional compounds like methyl esters, glycerol esters, and alkanes in exhaustive extracts. The major polymer antioxidant Irgafos 168 was also detected.
21 quantitative lc-msms analysis of 15 estrogens and estrogen metabolites in ...CPSA-2012_5-Minutes-Fame
Primera Analytical Solutions Corp. is an analytical chemistry contract research organization founded in 2002 that offers pharmaceutical and biotech companies a range of analytical services including GMP analytical testing, method development and validation, stability testing, bioanalysis of clinical samples, preformulation, and protein characterization. It has a team of PhD scientists, robust SOPs and quality systems, ICH-compliant stability chambers, and was FDA audited in 2008 and 2012 with no observations.
Intrapersonal intelligence refers to one's awareness and understanding of oneself, according to Howard Gardner's theory of multiple intelligences. Gardner proposed that people possess different types of intelligence and may be particularly strong in some types and weak in others. Those with high intrapersonal intelligence have a clear understanding of themselves and what they need in different settings. They tend to be self-reflective, perfectionistic, and prefer working alone. While they can lack interpersonal skills, developing these abilities through group work is important to prevent isolation. A lack of intrapersonal intelligence may contribute to inconsistent choices and failure to develop life goals.
This two-page test report from SGS Testing Korea Co., Ltd summarizes the results of testing samples of NEW MDK K INK BASE submitted by SAMYOUNG INK & PAINT MFG CO., LTD. The samples were tested for levels of perfluorooctanoic acid and perfluorooctane sulfonates and found to be not detected above the method detection limit of 1 mg/kg for both substances. The report provides details of the testing performed, samples analyzed, test methods used, and results obtained.
SGS Testing Korea Co., Ltd. conducted testing on ink samples submitted by SAMYOUNG INK & PAINT MFG CO., LTD. The testing screened for substances of very high concern according to the REACH regulation and found no substances above reporting limits. The report provides details on test methods, substances screened for, and results.
This document is a test report from SGS Taiwan Ltd. that summarizes the results of tests conducted on a sample of CORNING GORILLA® GLASS Style/Item No. GORILLA® 2319 provided by CORNING DISPLAY TECHNOLOGIES TAIWAN CO., LTD. The report details that testing was performed between December 10, 2015 and December 17, 2015 to analyze the sample for substances including cadmium, lead, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and phthalates. The test results indicated that all measured substances were not detected in the sample.
The document is a product specification sheet for SMD chip common mode chokes. It includes:
1. Product name, specifications, customer information, and contact details.
2. Description of the product shape, size, applications, features, and test equipment.
3. Standard electrical specifications including impedance, DC resistance, current rating, and tolerance.
4. Recommended PCB layout pattern, tape and reel specifications, common mode performance curve, and electrical performance test procedures.
5. Material safety data sheet.
1. The document is a test report from the Electronics Testing Center Taiwan that analyzes a sample of "Crystal Anti-Blue Light Tempered Glass Screen Protector" provided by Free S. speed international Co., Ltd.
2. The report details the test methods and results for substances like lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers. All results were below detection limits.
3. The report includes sample information, test results presented in a table, photos of the sample, and a flow chart of the testing process.
This document is an approval sheet from HT-TECH CORPORATION for a power inductor. It includes:
1. Specifications for the part number HNT2512MT1R0-E, including electrical characteristics, mechanical dimensions, and test conditions.
2. A coil inspection report with test data showing the part meets specifications for inductance, DC resistance, and physical dimensions.
3. Reliability test conditions and results for environmental and physical characteristic tests to ensure product quality and reliability.
The test report provides the results of chemical analysis of a sample received from DING OIL International Trade Co.,Ltd between October 5-15, 2015. The report details the testing methods used and findings for various properties such as specific gravity, viscosity, flash point, pour point, and levels of elements like sulfur, lead, cadmium and mercury. The sample was found to meet specifications for these characteristics and elements were either not detected or within allowed limits.
This document is a test report from an industrial safety laboratory. It provides test results for an unnamed product from an unnamed supplying/producing company in an unnamed origin country. The test report number and date are provided, as well as a note that the report cannot be separated or used if altered. Test results and detection limits are presented in a table, but no values are included. The supervisor's signature is present to verify the report.
This document provides test methods for analyzing phthalate content in children's products used by the U.S. Consumer Product Safety Commission (CPSC). It describes sample preparation, phthalate extraction, gas chromatography-mass spectrometry operating procedures, quality control measures, and calculations for determining phthalate concentration. Comments on the methods are encouraged by March 31, 2009. The general approach is to grind samples, dissolve in solvents, filter, dilute, and analyze by GC-MS, integrating peak areas to quantify six regulated phthalates.
This document is a resume for Prashant Mehta summarizing his professional experience and qualifications. He has over 10 years of experience working in chemical laboratories conducting environmental testing and analysis. His experience includes working as an organic extraction technician, GC analyst in semi-volatile and volatile organic departments, and wet chem analyst. He is proficient in various analytical techniques and instrumentation used to test parameters like oil and grease, COD, BOD, metals, and volatile and semi-volatile organics according to EPA methods. He aims to obtain a challenging position in chemical, environmental, or related industries.
This document is an approval sheet from HT-TECH CORPORATION for a customer. It includes:
1. Specification sheets describing the product specifications, dimensions, electrical characteristics, and reliability test conditions.
2. Inspection reports with test data for electrical characteristics and dimensions, as well as results within specifications.
3. SGS REPORT providing results of tests for various substances like lead, cadmium, mercury, and others, all of which were not detected above the method detection limits.
This document contains a summary of Haytham Mohammed Ahmed Aly's qualifications and work experience. It details his 20 years of experience as a chemist and laboratory manager at SIDPEC Petrochemicals Company in Egypt, where he currently serves as the Deputy Manager of the Ethylene, Utility and Environmental Research Department, overseeing 4 shift teams. It also lists his educational background and training certificates in chemistry and laboratory analysis techniques.
This document outlines the validation of an analytical method for quantifying gentamycin sulfate in gentamycin sulfate cream using a microbial assay. The method involves extracting gentamycin sulfate from cream samples using chloroform, then performing a cylinder plate assay with Staphylococcus epidermidis to quantify gentamycin sulfate levels. The validation will evaluate the method's specificity, precision, intermediate precision (ruggedness), and accuracy according to ICH guidelines. Responsibilities for developing and approving the validation protocol and performing testing are defined. The validation protocol describes the product profile, materials and equipment needed, analytical method, and performance parameters to be tested.
This poster describes analytical operating conditions for analysis of US EPA Method 8260C1, Revision 3, August 2006, and includes BFB tune parameters, calibration details, and a complete MDL and Precision and Accuracy study for almost 100 target compounds at multiple concentrations.
Peter Ndula has over 15 years of experience as a research scientist at Sasol leading projects in olefin tetramerization. He currently manages the polymer fouling mitigation project. He has extensive experience designing and running experiments in a continuous stirred tank reactor and analyzing resulting products. Ndula also has a background in quality control and teaching.
Jop description for Senior lab chemist ( shift leader)Haytham Aly
The document summarizes the duties and responsibilities of a senior lab chemist at an ethylene, utility, and environmental laboratory. Key responsibilities included supervising a shift team, ensuring correct and timely reporting of test results to customers, maintaining quality standards and accreditation, conducting safety audits, and being an expert in a wide range of analytical testing methods for samples like condensates, naphthas, gases, and amine solutions. Maintaining ISO/IEC 17025 accreditation and safety standards were priorities.
Read through our procedure handbook for the iScreen OFD saliva drug test kit. Perfect for pain management clinics and laboratories!
**Bulk pricing available!!**
Interested in learning more or placing an order? Give me a call at 858-875-0250 or send me an email to jjanke@confirmbiosciences.com!
This document describes a multi pass test stand that is used to test the performance of hydraulic and fuel filters according to ISO standards. The test stand injects filter elements with continuous contaminants while online particle sensors measure contamination levels, allowing for evaluation of the filter elements' performance. Test results are automatically generated into a report by the computer software. The test stand can test filtration performance, particle retention ability, contamination holding capacity, and differential pressure characteristics of filter elements.
iScreen OFD Oral Fluid Drug Screen ProceduresMichael Zures
Confirm BioSciences offers the iScreen OFD substance abuse screening device. This is a saliva drug test kit that tests for amphetamines, cocaine, methamphetamines, opiates, PCP & marijuana (THC).
This test is perfect for pre-employment drug testing and staffing agencies and using a mouth swab drug test removes the "ick" factor often associated with urine drug testing.
**Bulk pricing available!**
Interested in learning more or placing an order? Give me a call at 858-875-0266 or send me an email a mzures@gmail.com!
Tuv ROHS certificate --plastic pneumatic push in fittingsXHnotion Pneumatic
XHnotion pneumatic fittings get ROHS certificate from TUV.
This is new series fittings. Material is made from Nylon.
Lighter weight and corrision resistance.
This document discusses guidelines and best practices for handling out-of-specification (OOS) analytical results. It outlines procedures that regulatory agencies like the FDA recommend for investigating OOS results, including performing a preliminary assessment, full laboratory investigation, and documenting findings. The document emphasizes that OOS results should not be invalidated without a thorough investigation to identify the root cause and prevent future errors.
SGS Testing Korea Co., Ltd. conducted testing on ink samples submitted by SAMYOUNG INK & PAINT MFG CO., LTD. The testing screened for substances of very high concern according to the REACH regulation and found no substances above reporting limits. The report provides details on test methods, substances screened for, and results.
This document is a test report from SGS Taiwan Ltd. that summarizes the results of tests conducted on a sample of CORNING GORILLA® GLASS Style/Item No. GORILLA® 2319 provided by CORNING DISPLAY TECHNOLOGIES TAIWAN CO., LTD. The report details that testing was performed between December 10, 2015 and December 17, 2015 to analyze the sample for substances including cadmium, lead, mercury, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and phthalates. The test results indicated that all measured substances were not detected in the sample.
The document is a product specification sheet for SMD chip common mode chokes. It includes:
1. Product name, specifications, customer information, and contact details.
2. Description of the product shape, size, applications, features, and test equipment.
3. Standard electrical specifications including impedance, DC resistance, current rating, and tolerance.
4. Recommended PCB layout pattern, tape and reel specifications, common mode performance curve, and electrical performance test procedures.
5. Material safety data sheet.
1. The document is a test report from the Electronics Testing Center Taiwan that analyzes a sample of "Crystal Anti-Blue Light Tempered Glass Screen Protector" provided by Free S. speed international Co., Ltd.
2. The report details the test methods and results for substances like lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls, and polybrominated diphenyl ethers. All results were below detection limits.
3. The report includes sample information, test results presented in a table, photos of the sample, and a flow chart of the testing process.
This document is an approval sheet from HT-TECH CORPORATION for a power inductor. It includes:
1. Specifications for the part number HNT2512MT1R0-E, including electrical characteristics, mechanical dimensions, and test conditions.
2. A coil inspection report with test data showing the part meets specifications for inductance, DC resistance, and physical dimensions.
3. Reliability test conditions and results for environmental and physical characteristic tests to ensure product quality and reliability.
The test report provides the results of chemical analysis of a sample received from DING OIL International Trade Co.,Ltd between October 5-15, 2015. The report details the testing methods used and findings for various properties such as specific gravity, viscosity, flash point, pour point, and levels of elements like sulfur, lead, cadmium and mercury. The sample was found to meet specifications for these characteristics and elements were either not detected or within allowed limits.
This document is a test report from an industrial safety laboratory. It provides test results for an unnamed product from an unnamed supplying/producing company in an unnamed origin country. The test report number and date are provided, as well as a note that the report cannot be separated or used if altered. Test results and detection limits are presented in a table, but no values are included. The supervisor's signature is present to verify the report.
This document provides test methods for analyzing phthalate content in children's products used by the U.S. Consumer Product Safety Commission (CPSC). It describes sample preparation, phthalate extraction, gas chromatography-mass spectrometry operating procedures, quality control measures, and calculations for determining phthalate concentration. Comments on the methods are encouraged by March 31, 2009. The general approach is to grind samples, dissolve in solvents, filter, dilute, and analyze by GC-MS, integrating peak areas to quantify six regulated phthalates.
This document is a resume for Prashant Mehta summarizing his professional experience and qualifications. He has over 10 years of experience working in chemical laboratories conducting environmental testing and analysis. His experience includes working as an organic extraction technician, GC analyst in semi-volatile and volatile organic departments, and wet chem analyst. He is proficient in various analytical techniques and instrumentation used to test parameters like oil and grease, COD, BOD, metals, and volatile and semi-volatile organics according to EPA methods. He aims to obtain a challenging position in chemical, environmental, or related industries.
This document is an approval sheet from HT-TECH CORPORATION for a customer. It includes:
1. Specification sheets describing the product specifications, dimensions, electrical characteristics, and reliability test conditions.
2. Inspection reports with test data for electrical characteristics and dimensions, as well as results within specifications.
3. SGS REPORT providing results of tests for various substances like lead, cadmium, mercury, and others, all of which were not detected above the method detection limits.
This document contains a summary of Haytham Mohammed Ahmed Aly's qualifications and work experience. It details his 20 years of experience as a chemist and laboratory manager at SIDPEC Petrochemicals Company in Egypt, where he currently serves as the Deputy Manager of the Ethylene, Utility and Environmental Research Department, overseeing 4 shift teams. It also lists his educational background and training certificates in chemistry and laboratory analysis techniques.
This document outlines the validation of an analytical method for quantifying gentamycin sulfate in gentamycin sulfate cream using a microbial assay. The method involves extracting gentamycin sulfate from cream samples using chloroform, then performing a cylinder plate assay with Staphylococcus epidermidis to quantify gentamycin sulfate levels. The validation will evaluate the method's specificity, precision, intermediate precision (ruggedness), and accuracy according to ICH guidelines. Responsibilities for developing and approving the validation protocol and performing testing are defined. The validation protocol describes the product profile, materials and equipment needed, analytical method, and performance parameters to be tested.
This poster describes analytical operating conditions for analysis of US EPA Method 8260C1, Revision 3, August 2006, and includes BFB tune parameters, calibration details, and a complete MDL and Precision and Accuracy study for almost 100 target compounds at multiple concentrations.
Peter Ndula has over 15 years of experience as a research scientist at Sasol leading projects in olefin tetramerization. He currently manages the polymer fouling mitigation project. He has extensive experience designing and running experiments in a continuous stirred tank reactor and analyzing resulting products. Ndula also has a background in quality control and teaching.
Jop description for Senior lab chemist ( shift leader)Haytham Aly
The document summarizes the duties and responsibilities of a senior lab chemist at an ethylene, utility, and environmental laboratory. Key responsibilities included supervising a shift team, ensuring correct and timely reporting of test results to customers, maintaining quality standards and accreditation, conducting safety audits, and being an expert in a wide range of analytical testing methods for samples like condensates, naphthas, gases, and amine solutions. Maintaining ISO/IEC 17025 accreditation and safety standards were priorities.
Read through our procedure handbook for the iScreen OFD saliva drug test kit. Perfect for pain management clinics and laboratories!
**Bulk pricing available!!**
Interested in learning more or placing an order? Give me a call at 858-875-0250 or send me an email to jjanke@confirmbiosciences.com!
This document describes a multi pass test stand that is used to test the performance of hydraulic and fuel filters according to ISO standards. The test stand injects filter elements with continuous contaminants while online particle sensors measure contamination levels, allowing for evaluation of the filter elements' performance. Test results are automatically generated into a report by the computer software. The test stand can test filtration performance, particle retention ability, contamination holding capacity, and differential pressure characteristics of filter elements.
iScreen OFD Oral Fluid Drug Screen ProceduresMichael Zures
Confirm BioSciences offers the iScreen OFD substance abuse screening device. This is a saliva drug test kit that tests for amphetamines, cocaine, methamphetamines, opiates, PCP & marijuana (THC).
This test is perfect for pre-employment drug testing and staffing agencies and using a mouth swab drug test removes the "ick" factor often associated with urine drug testing.
**Bulk pricing available!**
Interested in learning more or placing an order? Give me a call at 858-875-0266 or send me an email a mzures@gmail.com!
Tuv ROHS certificate --plastic pneumatic push in fittingsXHnotion Pneumatic
XHnotion pneumatic fittings get ROHS certificate from TUV.
This is new series fittings. Material is made from Nylon.
Lighter weight and corrision resistance.
This document discusses guidelines and best practices for handling out-of-specification (OOS) analytical results. It outlines procedures that regulatory agencies like the FDA recommend for investigating OOS results, including performing a preliminary assessment, full laboratory investigation, and documenting findings. The document emphasizes that OOS results should not be invalidated without a thorough investigation to identify the root cause and prevent future errors.
1. Signature Not Verified
For Question,
Please Contact with SGS
www.tw.sgs.com
測試報告
號碼(No.) : CE/2009/76418 日期(Date) : 2009/08/06 頁數(Page) : 1 of 4
Test Report
立成貿易股份有限公司 *CE/2009/76418*
RISING TRADING CO., LTD.
台北市中山區松江路158號6樓之5
6FL-5, NO. 158, SUNG CHIANG RD., (104) TAIPEI, TAIWAN
以下測試樣品係由客戶送樣, 且由客戶聲稱並經客戶確認如下 (The following samples was/were submitted and
identified by/on behalf of the client as):
樣品名稱(Sample Description) : 底漆油 (SIZE)
樣品型號(Style/Item No.) : S-75-700
收件日期(Sample Receiving Date) : 2009/07/31
測試期間(Testing Period) : 2009/07/31 TO 2009/08/06
==================================================================================================================
測試結果(Test Results) : 請見下一頁 (Please refer to next pages).
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company.
This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention
is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings
at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd.
Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan / 33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com
Member of the SGS Group (SGS SA)
2. 測試報告
號碼(No.) : CE/2009/76418 日期(Date) : 2009/08/06 頁數(Page) : 2 of 4
Test Report
立成貿易股份有限公司 *CE/2009/76418*
RISING TRADING CO., LTD.
台北市中山區松江路158號6樓之5
6FL-5, NO. 158, SUNG CHIANG RD., (104) TAIPEI, TAIWAN
測試結果(Test Results)
測試部位(PART NAME) NO.1 : 透明液體 (TRANSPARENT LIQUID)
方法偵測 結果
測試項目 單位 測試方法
極限值 (Result)
(Test Items) (Unit) (Method)
(MDL) NO.1
全氟辛烷磺酸 / Perfluorooctane mg/kg 參考US EPA 3540C: 1996方法, 以液相 10 n.d.
sulfonates (PFOS) 層析質譜儀檢測全氟辛烷磺酸含量. /
PFOS – Acid With reference to US EPA 3540C:
PFOS – Metal Salt 1996 method for PFOS Content.
PFOS – Amide Analysis was performed by LC/MS.
全氟辛酸(銨) / PFOA (CAS No.: mg/kg 參考US EPA 3540C: 1996方法, 以液相 10 n.d.
000335-67-1) 層析質譜儀檢測全氟辛酸(銨)含量. /
With reference to US EPA 3540C:
1996 method for PFOA Content.
Analysis was performed by LC/MS.
備註(Note):
1. mg/kg = ppm;0.1wt% = 1000ppm
2. n.d. = Not Detected (未檢出)
3. MDL = Method Detection Limit (方法偵測極限值)
PFOS參考資訊(Reference Information) : 指令 2006/122/EC (Directive 2006/122/EC)
(1) 該物質不可置於市場上或使用於特殊物質或配置成分重量濃度等於或大於0.005%.
(May not be placed on the market or used as a substance or constituent of preparations in a
concentration equal to or higher than 0.005 % by mass.
(2) 該物質不可置於市場上的半成品或商品或其物件; 假若零件上明顯地具有PFOS並參照結構上及微細構造上計算
2
PFOS重量濃度等於或大於0.1%, 而紡織品或其他覆蓋物質, 如果PFOS在覆蓋物質中含量等於或大於1µ . g/m
(May not be placed on the market in semi-finished products or articles, or parts thereof, if the
concentration of PFOS is equal to or higher than 0.1 % by mass calculated with reference to the
mass of structurally or microstructurally distinct parts that contain PFOS or, for textiles or other
2
coated materials, if the amount of PFOS is equal to or higher than 1µ
g/m of the coated material.)
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company.
This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention
is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings
at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd.
Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan / 33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com
Member of the SGS Group (SGS SA)
3. 測試報告
號碼(No.) : CE/2009/76418 日期(Date) : 2009/08/06 頁數(Page) : 3 of 4
Test Report
立成貿易股份有限公司 *CE/2009/76418*
RISING TRADING CO., LTD.
台北市中山區松江路158號6樓之5
6FL-5, NO. 158, SUNG CHIANG RD., (104) TAIPEI, TAIWAN
全氟辛酸(銨)/全氟辛烷磺酸分析流程圖/
Analytical flow chart of PFOA/PFOS content
1) 測試人員:劉家瑗 / Name of the person who made measurement: Carrie Liu
2) 測試負責人:陳新智 / Name of the person in charge of measurement: Shinjyh Chen
樣品前處理 /
Sample pretreatment
索式萃取法萃取
(參考方法 US EPA 3540C) /
Sample extraction by Soxhlet extraction
(Reference method US EPA 3540C)
萃取液稀釋 /濃縮 /
Concentrate/Dilute Extracted solution
以液相層析質譜儀分析萃取液 /
Analysis was performed by LC/MS
數據 / Data
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company.
This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention
is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings
at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd.
Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan / 33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com
Member of the SGS Group (SGS SA)
4. 測試報告
號碼(No.) : CE/2009/76418 日期(Date) : 2009/08/06 頁數(Page) : 4 of 4
Test Report
立成貿易股份有限公司 *CE/2009/76418*
RISING TRADING CO., LTD.
台北市中山區松江路158號6樓之5
6FL-5, NO. 158, SUNG CHIANG RD., (104) TAIPEI, TAIWAN
** 報告結尾(End of Report) **
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested. This test report cannot be reproduced, except in full, without prior written permission of the Company.
This Test Report is issued by the Company under its General Conditions of Service printed overleaf or available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. Attention
is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this Test Report is advised that information contained hereon reflects the Company’s findings
at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and
offenders may be prosecuted to the fullest extent of the law.
SGS Taiwan Ltd.
Chemical-Taipei 33 WuChyuan Road, Wuku Industrial Zone, Taipei County, Taiwan / 33 t + 886 (02)2299 3279 f + 886 (02)2299 3237 www.sgs.com
Member of the SGS Group (SGS SA)