History of the “Big Rig” Events
NHL “Big Rig”...NHL “Big Rig”...
The Call to DutyThe Call to Duty
Dan Craig
NHL Facility Operations Manager
Event Teams Weather
2009 Winter Classic
Wrigley Field, Chicago
vs
00
C
Overcast
2010 Winter Classic
Fenway Park, Boston
vs
10
C
Overcast
2011 Winter Classic
Heinz Field, Pittsburgh
vs
100
C
Overcast
2011 Alumni Game
Heinz Field, Pittsburgh
vs
100
C
Overcast
2011 Heritage Classic
McMahon Stadium, Calgary
vs
-150
C
Partly Cloudy
2012 Winter Classic Citizens
Bank Park Philadelphia
vs
30
C
Mostly Cloudy
2014 Winter Classic
Michigan Stadium, Ann Arbor
vs
-110
C
Light Snow
2014 Stadium Series
Dodger Stadium, Los Angeles
vs
250
C
Overcast
2014 Stadium Series
Yankee Stadium, New York
vs
-80
C
Clear
2014 Stadium Series
Yankee Stadium, New York
vs
-60
C
Clear
2014 Stadium Series
Soldier Field, Chicago
vs
-50
C
Overcast
2014 Heritage Classic
BC Place, Vancouver
vs
Indoor
2015 Winter Classic
Nationals Park, Washington
vs
70
C
Mostly Cloudy
2015 Stadium Series
Levi’s Stadium, Santa Clara
vs
200
C
Partly Cloudy
2016 Winter Classic
Gillette Stadium, Foxborough
vs
50
C
Overcast
2016 Stadium Series
TCF Bank Stadium, Minneapolis
vs
20
C
Overcast
2016 Stadium Series
Coors Field, Denver
vs
210
C
Mostly Cloudy
“My experience with CIMCO started when I worked
at the Rexall Place in Edmonton. I have been in the
business for a number of years and have not seen
another company as experienced and professional
as CIMCO. They provide the best refrigeration
mechanics in the world. Being in the NHL spotlight I
cannot afford to cut any corners when it comes to
maintaining our plants.”
“Big Rig” Specifications“Big Rig” Specifications
Refrigerant:
 R717 (Ammonia)
Two Compressors for a total of 310TR:
RXF 85 compressor
 140TR (10°F Evaporating temperature and 95°F condensing
temperature)
 235HP motor
 Quantum LX Microprocessor
RXF-101 Compressor
 170TR (10°F Evaporating temperature and 95°F condensing
temperature)
 263 HP motor
 Quantum LX Microprocessor
Evaporative condenser Model: Evapco LRC-379
 Capacity 4760 MBH
 40HP fan motor
Alfa Laval Plate and Frame heat exchanger:
 Model T20-BWFS
 13340 lb/hr ammonia flowrate
 857300 Lb/hr glycol flowrate
 Glycol supply temperature 15°F
 Complete with 42” surge drum
Pumps (2)
 Armstrong base mounted end suction pumps
 1400gpm
 40HP each
Trailer
 53’ step deck trailer
 Manufacturer Di-Mond Trailers in Burlington.
 65,000 Lbs Gross Weight, with equipment
Electrical
 460V/3ph/60hz power from Generator typically
 591 HP total
 1055 FLA
www.cimcorefrigeration.com

NHL Trailer FS (4)

  • 1.
    History of the“Big Rig” Events NHL “Big Rig”...NHL “Big Rig”... The Call to DutyThe Call to Duty Dan Craig NHL Facility Operations Manager Event Teams Weather 2009 Winter Classic Wrigley Field, Chicago vs 00 C Overcast 2010 Winter Classic Fenway Park, Boston vs 10 C Overcast 2011 Winter Classic Heinz Field, Pittsburgh vs 100 C Overcast 2011 Alumni Game Heinz Field, Pittsburgh vs 100 C Overcast 2011 Heritage Classic McMahon Stadium, Calgary vs -150 C Partly Cloudy 2012 Winter Classic Citizens Bank Park Philadelphia vs 30 C Mostly Cloudy 2014 Winter Classic Michigan Stadium, Ann Arbor vs -110 C Light Snow 2014 Stadium Series Dodger Stadium, Los Angeles vs 250 C Overcast 2014 Stadium Series Yankee Stadium, New York vs -80 C Clear 2014 Stadium Series Yankee Stadium, New York vs -60 C Clear 2014 Stadium Series Soldier Field, Chicago vs -50 C Overcast 2014 Heritage Classic BC Place, Vancouver vs Indoor 2015 Winter Classic Nationals Park, Washington vs 70 C Mostly Cloudy 2015 Stadium Series Levi’s Stadium, Santa Clara vs 200 C Partly Cloudy 2016 Winter Classic Gillette Stadium, Foxborough vs 50 C Overcast 2016 Stadium Series TCF Bank Stadium, Minneapolis vs 20 C Overcast 2016 Stadium Series Coors Field, Denver vs 210 C Mostly Cloudy “My experience with CIMCO started when I worked at the Rexall Place in Edmonton. I have been in the business for a number of years and have not seen another company as experienced and professional as CIMCO. They provide the best refrigeration mechanics in the world. Being in the NHL spotlight I cannot afford to cut any corners when it comes to maintaining our plants.”
  • 2.
    “Big Rig” Specifications“BigRig” Specifications Refrigerant:  R717 (Ammonia) Two Compressors for a total of 310TR: RXF 85 compressor  140TR (10°F Evaporating temperature and 95°F condensing temperature)  235HP motor  Quantum LX Microprocessor RXF-101 Compressor  170TR (10°F Evaporating temperature and 95°F condensing temperature)  263 HP motor  Quantum LX Microprocessor Evaporative condenser Model: Evapco LRC-379  Capacity 4760 MBH  40HP fan motor Alfa Laval Plate and Frame heat exchanger:  Model T20-BWFS  13340 lb/hr ammonia flowrate  857300 Lb/hr glycol flowrate  Glycol supply temperature 15°F  Complete with 42” surge drum Pumps (2)  Armstrong base mounted end suction pumps  1400gpm  40HP each Trailer  53’ step deck trailer  Manufacturer Di-Mond Trailers in Burlington.  65,000 Lbs Gross Weight, with equipment Electrical  460V/3ph/60hz power from Generator typically  591 HP total  1055 FLA www.cimcorefrigeration.com