Iowa State University
Ames, Iowa
IE 571
Occupational Biomechanics
Single Hand Held Controller Ergonomic Evaluation
Final Exam
Thomas M. Schnieders
4 May 2015
I E 5 7 1 F i n a l E x a m | 2
Table of Contents
Table of Contents............................................................................................................................ 2
Table of Figures .............................................................................................................................. 3
List of Tables................................................................................................................................... 3
List of Appendices........................................................................................................................... 3
I. Executive Summary..................................................................................................................... 4
II. Introduction ................................................................................................................................. 5
III. Schedule ...................................................................................Error! Bookmark not defined.
IV. Customer Requirements Specification...................................................................................... 6
Statement of Need .......................................................................................................................... 6
System Descriptions and Functions ............................................................................................... 8
Function Tree.................................................................................................................................. 8
Function Chart and Block Diagrams............................................................................................... 9
Operating Environment................................................................................................................. 11
Deliverables .................................................................................................................................. 12
V. Market Research...................................................................................................................... 12
VI. Global and Social Impacts....................................................................................................... 12
VII. Recommendations and Design Concepts for the Redesign ................................................. 13
System specification..................................................................................................................... 13
Key Technical Challenges ............................................................................................................ 13
Ergonomic Evaluation................................................................................................................... 14
Testing of controller ...................................................................................................................... 17
Ergonomic Improvements and Design Concepts......................................................................... 19
Mathematical Verification of the Redesign................................................................................... 22
Trade Studies................................................................................................................................ 23
VII. Future Work............................................................................................................................ 24
VIII. References ............................................................................................................................ 25
I E 5 7 1 F i n a l E x a m | 3
Table of Figures
Figure 1: CAD-model of the Single Hand Held Controller………………………………………7
Figure 2: Function Tree of the Single Handle Controller…………………………………………8
Figure 3: Functional Flow Chart for single hand held controller…………………………………9
Figure 4: Muscles of the Back…………………………………………………………………...15
Figure 5: Muscles of the Forearm………………………………………………………………..16
Figure 6: How the test stand was assembled…………………………………………………….16
Figure 7: The hand controller set together with the test stand…………………………………...17
Figure 8: The pistol grip concept………………………………………………………………...19
Figure 9: The forces affecting the arm from the existing model………………………………...20
Figure 10: The extra handle to counteract torque in the body…………………………………...20
List of Tables
Table 1: Classification of force/torque for selection of manual control actuators……………….14
Table 2: Minimum recommended dimensions of manual control actuators……………………..14
Table 3: Results from the calculations…………………………………………………………...22
List of Appendices
Appendix A: Customer Requirement Benchmarking
Appendix B: ISO 9355-3: 2006
Appendix C: Matlab Code
Appendix D: Body Part Discomfort Chart
Appendix E: Borg CR10 Scale
Appendix F: Force Recording
Appendix G: New Handle
Appendix H: Extra Handle
Appendix I: Part 00001
Appendix J: Part 00002
Appendix K: Part 00003
Appendix L: Part 0004
Appendix M: Part 0005
Appendix N: Part 0006
Appendix O: Part 0007
Appendix P: Part 0008
I E 5 7 1 F i n a l E x a m | 4
I. Executive Summary
Included in this report is a project plan for the project “Single Hand Held Controller,” for IE 571,
Occupational Biomechanics at Iowa State University. The project plan details statement of need,
customer requirements, and market research. The project is for by Altec, a leading provider of
products and services ranging from electric utility to contractor markets. Paul Zinnel and Chris
Barnes will be the team’s primary contacts at Altec. The team will be advised by Dr. Mani Mina.
The evaluation is on pilot pressure hand held controllers and will initially focus on the
ergonomic standards research and evaluation. The report ends with an evaluation on full pressure
hand held controllers, the design and building of a test platform, a redesign of the original
controller and other suggestions for Altec.
The purpose of this project is to find ergonomic standards that relate to single handle controllers
and aerial devices, design and develop a test platform and method for testing Altec’s iso grip
controllers, and evaluate if Altec’s controllers meet ergonomic standards. The reason for the
project comes from high strain in the shoulder and arm on operators during two and three
function movements. By analyzing, testing, and simulating these forces, an ergonomic evaluation
will be completed and suggestions and recommendations for a redesign will be proposed. A
redesigned prototype will be submitted which will meet the ergonomic standards.
I E 5 7 1 F i n a l E x a m | 5
II. Introduction
Ergonomics has become a topic of larger importance over the recent decades and is a significant
aspect for individuals and companies in more than one way. Poor ergonomic conditions can
cause more severe issues than one might think. Many workers are injured in the workplace due
to incorrect ergonomic conditions, which usually consist of attritional wear due to incorrect
movements, strains, and lifts.
Ergonomics also affects the company in a larger degree, regarding the economic and productive
aspects. An injury caused by work related conditions is a cost for the injured employee,
company, and society. By reducing the risks for strain injury or attritional wear with better
ergonomic standards and conditions at the job site, savings of resources for the company,
employee, and society can occur. A company with good ergonomic conditions and products are
more competitive and are more attractive as an employer.
Altec, a company which was established over 80 years ago, delivers products and services in
more than 100 countries worldwide. Their core values include putting the customer first,
enjoyment of work, and quality. With this stated, their products need to meet good ergonomic
conditions since they are used daily by their customers. One subject of ergonomic discussion is
their single hand held controller used in aerial devices. Operators of the aerial devices use the
single hand held controller during a work day, which could range in length from 1-8 hours per
day. This requires that the controllers meet good ergonomic conditions in order to prevent
injuries caused by the controller and ease utilization.
In order to supply Altec an ergonomic evaluation of the single hand held controller and suggest a
redesign, specific requirements have to be met.
I E 5 7 1 F i n a l E x a m | 6
IV. Customer Requirements Specification
Statement of Need
Altec offers many different products such as digger derricks, pressure diggers, and ground pole
drivers. However, the focus of the MD5 team will be on the aerial trucks. The aerial trucks are
the units utilized for power line access. There are four main types of aerial trucks produced by
Altec: the Non-Overcenter, the Overcenter; the Telescopic; and the Telescopic Articulating. The
Non-Overcenter (Figure I) line of trucks has lift baskets that are capable of reaching up to 150
ft. The Overcenter can reach heights up to 93.3 ft. The Telescopic can reach heights up to 63 ft.
Lastly, the Telescopic Articulating line can reach heights up to 64.8 ft.
Figure 1: An example of a Non-Overcenter aerial truck
The controller utilized to operate the lift basket of the aerial trucks is a trademark patent of the
company. The controller is designed for one-arm operations, and there are two main types of
controllers: full-pressure (Figure 2) and pilot-pressure (team MD5 will work with the full-pressure
controller). Both controller types operate on a hydraulic system; however; the pilot-pressure
controller has a secondary pressure system that serves as median between the user and the main
I E 5 7 1 F i n a l E x a m | 7
hydraulic system. Thus, the hydraulic system is more efficient in delivering power to necessary
functions.
Figure 2: Side view of the controller
Altec Industries have several different single hand held controllers to maneuver their products.
Over the last few years there have been customer complaints about fatigue caused by their iso
grip controllers, especially during two and three function movements that involve pulling the
controller backwards and upwards at the same time. Altec desires to investigate the ergonomics
surrounding the single handle controller and see whether it matches any ergonomic standards. If
it does not fit ergonomic standards, Altec would like to be provided with an alternative design or
improvements that could solve the problem and alleviate fatigue.
Figure 3: CAD-model of the Single Hand Held Controller
The problem is most prominent when operators use an upwards and backwards motion
simultaneously. Additionally, the slow movement of the boom leads to more time required to
I E 5 7 1 F i n a l E x a m | 8
hold the controller using the safety interlock system. It is also very important that the
improvements do not include an electrical systems since the product is supposed to be used in an
environment where electricity is not suitable and could be fatal. Additionally, Altec’s controller
falls under the ANSI/SIA A92.2-2009 Vehicle-Mounted Elevating and Rotating Aerial Devices
standard. The improvements or new design must also fit the dimensions of the controller box
previously used.
To determine whether the controller fits the ergonomic standards there must be a method for
testing the forces on the controllers. This method will preferably be a physical model designed
and manufactured which should be suitable for the six different controls.
System Descriptions and Functions
Function Tree
Figure 2, below, demonstrates the two different operating systems of the single handle controller.
The positioning system is the system causing fatigue, strain and uncomfortable movements of the
arm and shoulder. The safety system is an essential system for the single handle controller and
will have to have the same fundamental design in a redesign, due to its function and importance
during utilization of the single handle controller.
Figure 4: Function Tree of the Single Handle Controller
I E 5 7 1 F i n a l E x a m | 9
Function Chart and Block Diagrams
In Figure 5, below, the specific functions of the single hand held controller are shown. For a
possible redesign and prototype, all these functions need to be considered, evaluated and
retained. The functions of positioning the cubicle, see figure 3 below, of the aerial device can be
divided in to the functions listed in Figure 4.
Figure 5: Functional Flow Chart for single hand held controller
The definitions of the functions are listed below:
Move Up/Down: Move and position the cubicle upwards and downwards in a vertical direction
by pulling/pushing the single hand held controller upwards/downwards.
Move Back and Forward: This function on the single hand held controller is interconnected with
the Move Up/Down function. While moving the cubicle from starting base position (horizontal
position) to an upright vertical position, the joint connecting the two shafts will force a motion
I E 5 7 1 F i n a l E x a m | 10
where the cubicle will move backwards and forwards while positioning into a vertical upright
position. By pushing the single hand held controller forward/backward the cubicle will move
forwards/backwards.
Interlock: As a safety measure the single hand held controller has a lever which needs to be
pressed in while operating the cubicle of the aerial device. If the interlock is not pressed in it is
not possible to use the controller for any operations.
The Move Up/Down function and Move Back/Forward can be combined into a two-function
movement operation. This functionality is a customer requirement to retain during the project
and all functions listed above are necessary to retain for a redesign of the single hand held
controller.
All three functions can also be combined into a three-function operation. This report will not
focus on this.
A detailed breakdown of the control interface is featured in Figures 6 - 11. The interlock linkage
(Figure 7) is the safety feature that prevents the user from experiencing a self-induced controller
response. Essentially, this means that the lift arms (also known as booms) can only move while
the handle of the controller is squeezed. Pushing forward or backward on the controller activates
the linkages featured in Figure 8. These motions raise and lower the bottom boom of the aerial
truck. Pulling up and down on the controller activates the linkages featured in Figure 9. These
motions raise and lower the upper boom. Tilling and twisting the controller activates the linkages
in Figures 10& 11, respectively. These motions allow the user to rotate the lower boom in a circular
pattern. The controller is also capable of performing compound movements. For example, the
controller can be orientated so that the operator can raise the lower and upper booms and rotate
the lower boom.
I E 5 7 1 F i n a l E x a m | 11
Figure 6: Linkages for motion Figure 7: Interlock linkage Figure 8: Forward/
Backward control
control linkage
Figure 9: Up/ Down Control Figure 10: Tiller control Figure 11: Twist
control linkage linkage
linkage
Operating Environment
The single hand held controllers are used in the cubicle of the skylift of the aerial devices. The
operators use the single hand held controllers during a work shift ranging from one to eight
hours. The major part of the work is performed in an outdoor environment and the operators
spend most of their shift in the cubicle. Depending on what type of work is performed, the single
handle controller is used a number of different ways and the operator’s arm can be in different
I E 5 7 1 F i n a l E x a m | 12
positions. One operator might only use the single handle controller to position the cubicle to get
up to and down from the working site, while another operator might have a job which includes
needing to position the cubicle several times during one work shift. Hence, the usage of the
single handle controller differentiates depending on the tasks that need to be performed by the
operator, leading to different working conditions for each operator. Some of the aerial devices
are also used to work on power lines, which directly demands an isolated and non-electrical
controller.
Deliverables
At the end of this project, a final report, recommendations, a set of ergonomic standards, and an
analysis of Altec’s controllers will be presented with notes on how to improve the ergonomics of
the controllers. A testing stand and testing procedure for force testing on the controllers will also
be delivered to Altec. Additionally, if time permits, a prototype of the improved handle will be
delivered either in CAD format or physical prototype. Force data and MATLAB calculations will
be performed for the original controller and presented in the final report, and MATLAB
estimations will be performed for the prototype.
V. Market Research
There are two primary systems to look at in the market – Altec’s ISO-Grip Control system and a
scissor lift controller. A breakdown of their benchmarking may be seen in Appendix A, attached.
Note that the customer requirement ranking is broken down as such: rank 9: “Very Important”,
rank 3: “Moderately Important”, Rank 1: “Minor Important”. The option preference ranking is as
follows: rank 9: Requirement “Strongly” Met, Rank 3: Requirement “Moderately” Met, and rank
1: Requirement “Barely” Met.
VI. Global and Social Impacts
The ergonomic evaluation will supply Altec with recommendations regarding ergonomic
standards and suggestions for better ergonomic conditions for the single handle controller. With
this Altec can chose to use the evaluation and improve the ergonomic conditions of the single
I E 5 7 1 F i n a l E x a m | 13
handle controller. By doing so, Altec will be more competitive in the market with supplying
aerial devices with better ergonomic controllers. Altec will be more attractive to customers, since
good ergonomic conditions will improve the work environment and productivity of any company
which is very beneficial for both Altec as for their customers who are leasing or buying the aerial
devices. Consequently, it might lead to Altec creating new relations and gaining more customers,
thus increasing its revenue and gaining a lead in the different markets Altec provides services
and products in.
An ergonomically improved single hand held controller also enables work possibilities and
opportunities for elder operators. Avoiding fatigue, strain issues and complications as the
operators get older allows them to work until retirement and the companies avoid having to pay
for medical expenses. A better ergonomic control invites for a more pleasant and work friendly
environment as an operator of the aerial devices. Operators will evade possible physical and
mental pain due to injuries caused by a less ergonomic controller.
In summary, more ergonomically fit single handle controllers and devices in general are
preferred due to the many benefits to employees, employers, and leasing companies.
VII. Recommendations and Design Concepts for the Redesign
System specification
There are specific functional structures which need to be considered for a possible redesign of
the single hand held controller. Specific functions of the single hand held controller need to be
retained to meet Altec’s requirements for the project and the controller. As stated in the
Customer Requirement Specifications section, there are five main functions of the single hand
held controller, which are to be retained in any redesign.
Key Technical Challenges
I E 5 7 1 F i n a l E x a m | 14
The key technical challenge for the design and function of the single hand held controller is that
it cannot be electrical. Due to the Customer Requirements, the hand held controller is acquired to
be entirely isolated and operated with nothing more than forces, torques, and hydraulics. For the
redesigned single hand held control the same requirements have to be met. The key challenge
would therefore be to design a hand held control with smoother operation without using
electronics.
Furthermore, the single hand held controller is to be locked and not moveable, therefore, another
technical challenge is to make the handheld controller more ergonomic without being able to
change the height of the control to suit the length of the operator. It is also to be fit into the box
where it is positioned in the cubicle, which constrains the size of the controller.
Ergonomic Evaluation
The team was only able to locate one ergonomic standard that relates to Altec’s iso grip handle --
ISO 9355-3:2006 Ergonomic requirements for the design of displays and control actuators --
Part 3: Control actuators. The standard’s abstract is as follows: ISO 9355-3:2006 gives
ergonomic requirements for, and guidance on, the selection, design and location of control
actuators adapted to the needs of the operator, suitable for the control task in question and
taking account of the circumstances of their use. It is applicable to manual control actuators
used in equipment for both occupational and private use. The 40 page standard can be seen in
Appendix B. Team MD 6 utilized four subject matter experts to locate the most relevant
standard.
Alex Renner, PhD candidate, was the team’s first point of contact. Thomas Schnieders worked
with Mr. Renner in the Virtual Reality Applications Center. Mr. Renner has many years of
experience in manufacturing and mechanical engineering working with ergonomics in the
workplace. Mr. Renner gave the team a number of textbooks to reference and facilitated the 3D
printing of the prototype handle.
Dr. Jason Gillette was the team’s second contact. Dr. Gillette received his masters and doctorate
at Iowa State University in Biomechanics and teaches courses on Biomechanics and injury
I E 5 7 1 F i n a l E x a m | 15
prevention in the workplace. Dr. Gillette also gave the team a few text resources as well as a
short list of things to consider while re-designing the controller. Dr. Gillette pointed the team to
Dr. Gary Mirka and Dr. Rick Stone to help in the search of an ergonomic standard. Dr. Mirka
and Dr. Stone work with standards on a regular basis. Additionally, Dr. Stone does research in
ergonomics and biomechanics. Dr. Stone suggested the use of the ISO 9355-3:2006 standard and
the three other subject matter experts agreed on the decision.
The ISO standard details out suggestions for design and gives a standard of force values for
control actuators in section 5.2.3 Task requirement c) – Classification of force/torque (force)
(Table 1).
Table 1: Classification of force/torque for selection of manual control actuators
Additionally, the standard provides a listing for minimum dimensions of manual control
actuators (section 8.2 of the standard). A copy of that data can be seen in the table below. Altec’s
controller meets this standard.
Table 2: Minimum recommended dimensions of manual control actuators
I E 5 7 1 F i n a l E x a m | 16
Guidelines for single handle controllers have been evaluated and applied on the Altec’s pilot
pressure single handle controller. The guidelines discuss size of handles, angles and positions of
arm and body and how to best reduce forces, strain and fatigue on the body.
There are some ergonomic standards and guidelines on how the handle should be modelled and
the current handle was within acceptable range. The most common problem with handles is that
they are either too big/small, stiff, awkwardly placed or slippery. The handle was at an
acceptable size and not slippery, thanks to the Altec logo, and not too stiff. There was, however,
a problem with the placement of the controller. Based on the ISO standard, as well as discussions
with Dr. Stone and Dr. Gillette, the placement of the controller creates an unnatural wrist angle
which can lead to strain and fatigue in the wrist, shoulder, and forearm.
From the team’s discussions with Dr. Stone, Dr. Mirka, and Dr. Gillette, as well as repeated
manual testing, the team noted that the stress and fatigue would be most prominent in the
following muscles: the latissimus dorsi, the trapezius, the levator scapulae, the flexor
retinaculum, the pronator quadratus, and the brachioradialis (see figures 4 & 5).
Figure 4: Muscles of the Back
I E 5 7 1 F i n a l E x a m | 17
Figure 5: Muscles of the Forearm
Testing of controller
The testing was done using a force gauge meter where strings were attached to the handle of the
controller. The controller was positioned in a test stand that was developed. The test stand was
then manufactured by Altec. The test stand consists of 4 parts that was assembled with bolts and
nuts. Then the hand controller was attached with bolts and nuts to the test stand, as seen in Figure
6. The drawing files for the test stand can be seen in Appendix I through P, attached.
Figure 6: How the test stand was assembled
I E 5 7 1 F i n a l E x a m | 18
The test stand was then locked in position with c-clamps to make sure nothing but the controller
itself would be able to move during the testing. The final set up for testing should look like
figure 7, below. The test stand would be suitable for the EMG-testing as well as for the force
gauge testing.
Figure 7: The hand controller set together with the test stand
The strings were then connected to the gauge meter and pulled from the approximate center of
the controller’s handle until the controller reached its maximum movable distance. To make sure
the controller moved its full range of motion, the team first pushed or pulled the controller to its
full extent. The values the team were after were the minimum amount of force required for the
controller to reach its maximum distance in each of the primary directions. To normalize the
data, it was collected from three different individuals and an average was calculated. A larger
sample size would have been preferable, however, the team is confident that the data would still
average out to a very similar result.
The highest value was 10.2 lbs or 45.37 N and the lowest value was 4.2 lbs or 18.68 N. These
results made it possible to determine which of the controllers were the stiffest based on the
average values and it was controller 970042561. The least stiff was controller 716-61949. The
recorded forces may be seen in Appendix F. The accuracy of the measurements are not the best,
but the average gives somewhat of a correct estimate since all of the independent measured
forces was within an acceptable interval.
I E 5 7 1 F i n a l E x a m | 19
Most of the forces fell within the average degree of requirements found in the ISO 9355-3
standard, this can also be seen in Table 2, above. For Altec’s iso-grip controller, the forces
should lie in the low to negligible range found in the table, indicating that the controller could
use a redesign to best fit within the ergonomic standard.
Additional EMG data was to be collected to show which muscles were experiencing the greatest
strain. EMG, or electromyography essentially measures the electrical impulses produced by
skeletal muscles as a result of movement. The higher the amount of electrical potential generated
by muscle cells, the higher the signal recorded. In other words, the more force required of the
muscles, which can indicate strain and load bearing, the higher the output. Every individual’s
musculature is essentially the same but there are slight differences. This difference can be
normalized by comparing an individual’s EMG data for the original controller, coupled with the
force data, against the same individual’s EMG and force data against the redesigned prototype.
With the help of their subject matter experts a hypothesize was formed about which muscles
would experience strain. Even though a total of fifteen user study participants were found, due to
time constraints and lack of availability with Dr. Stone, the data was unable to be collected. This
data would have shown clearer results, but since the mathematical model, see Mathematical
Verification of Redesign, and the measured forces gives an estimation regarding whether the
controllers fulfill the ergonomic standards or not.
Ergonomic Improvements and DesignConcepts
To be able to reduce the strain on the wrist, forearm, and shoulder the angle of the handle needed
to be changed. There were different design concepts that would have improved the angle, but the
final concept was to change the grip to a pistol grip, as seen in Figure 5. The redesigned handle
may also be seen in Appendix G, the relevant SolidWorks files may be seen in the relevant folder
on CyPoint. This design was chosen through the use of the ISO 9355-3 standard, the textbook
references on biomechanics, and the recommendations of Dr. Stone and Dr. Gillette.
Additionally, the team chose this concept because it would be the least expensive option,
I E 5 7 1 F i n a l E x a m | 20
whereas other concepts involved replacing more than one part in each of the already existing
controllers.
Figure 8: The pistol grip concept
The pistol grip concept changes the force distribution in the arm and back reducing the strain.
The force required to hold in the interlock to be able to operate the controller is negligible and is
therefore not considered to be a problem.
In the original design for the iso grip controller, the wrist would be bent downward causing point
T2 (see Figure 9, below) to swing out away from the body creating a torque in the elbow joint as
well as in the wrist and shoulder. This created high strain in the levator scapulae and the
supraspinatus. Additionally, fatigue could result in the triceps and trapezius from repeated usage.
The pistol grip provides a much more natural movement reducing the strain in the levator
scapulae, the supraspinatus, the latissimus dorsi, the trapezius, the flexor retinaculum, the
pronator quadratus, and the brachioradialis. Furthermore, the fatigue in the triceps and trapezius
is also reduced. I was hoping to be able to further back its findings with relevant EMG data.
I E 5 7 1 F i n a l E x a m | 21
Figure 9: The forces affecting the arm from the existing model
The second recommendation is an extra handle for the other arm, see Figure 10, attached to the
cubicle. The extra handle may be seen in Appendix H.. The extra handle would help counteract
the torque using the handheld controller which could potentially reduce strain and fatigue in the
internal and external obliques and the latissimus dorsi. When pulling with a force F1, for
example, there will be a clockwise torque in the body and this could be counteracted by applying
a counter torque via the extra grip.
Figure 10: The extra handle to counteract torque in the body
The twist motion is very non-ergonomic according to Dr. Stone, especially when using the
already existing grip. The best ergonomic solution would be to exclude the twist motion entirely.
The muscles of the human body are optimal when movements are in line with the body.
I E 5 7 1 F i n a l E x a m | 22
A combination of the pistol grip and extra handle would, theoretically, reduce the forces and
torques applied on the joints and muscles to the low and negligible sections for degree of
requirements. This combination keeps the body’s limbs in line allowing for peak performance
with minimal force.
A model of the redesigned prototype with the pistol grip was 3D printed using the Virtual Reality
Applications Center’s Makerbot Replicator 2X to help affirm the change in ergonomics with a
change in grip style.
Mathematical Verification of the Redesign
To evaluate the redesigned prototype in an ergonomic point of view a mathematical model was
set up. The model is derived from Figure 9.
By calculating the torque in three joints of the arm; the wrist, the elbow, and the shoulder it
should be easy to see if the prototype has decreased the strain that is a result of the torque. It is
assumed that the forces that is needed to operate the existing joystick, is also needed to operate
the redesigned prototype. Meaning that the forces used in this model will be the measured forces
from the testing and they will be constant. The lengths l1, l2 and l3 will also be kept constant in
both cases. The input variables consists of the angles θ1, θ2 and θ3, which will vary between the
existing controller and the prototype and has been measured during operation of both of them.
The calculations were done in MatLab and may be seen in the attached Appendix C.
The results from the calculations is ambiguous and shows that the torque is reduced in some of
the joints with the redesign, but it also shows that it increases in some of the other joints, see
Table 3. These calculations doesn’t show which of the two designs is the most ergonomic.
However, Altec’s main customer complaints were about the two function movement that
included the Pull Up and the Pull Backward move. During this specific move the torque has
decreased with the redesign. The team still strongly believes the redesign is more ergonomic.
The EMG data would help show the ergonomic difference based on muscle activity.
I E 5 7 1 F i n a l E x a m | 23
Table 3: Results from the calculations
Trade Studies
For Altec, a new single handle control would certainly be a major investment with an uncertainty
in profitability. The current single handle controllers have been in utilization since 2001 and all
the aerial devices are equipped with either the pilot pressure single handle controller or a similar
controller. Thus, leading to a difficult decision making on which ways would be the better
balanced solutions for Altec and their customers.
An entirely redesigned single handle control would be a tremendous expense, even to an
established company like Altec. The time for redesigning, cost of production, replacing the
current controllers and to educate the operators in how to use the new single handle control
might be superfluous for Altec. Altec already has devoted and established customers, meaning
that Altec might not be in a need to execute such an extensive transformation for the single
handle controller used in the aerial devices. In order to pursue that kind of adjustment, the
customer complaints have to more extensive and larger in number to prove the necessity of a
redesign. An extended examination and complaint analysis has to be performed in order to
understand and assess the complaints on pain, fatigue and injuries after using the single handle
I E 5 7 1 F i n a l E x a m | 24
controller. The team recommends that Altec has the companies who are filing complaints have
their workers fill out a Body Part Discomfort Chart (Appendix D) and a Borg CR10 Scale
(Appendix E).
One possibility for Altec and the customers is to apply some of the ergonomic recommendations
in this report, such as implementing a supportive handle. By doing so, Altec can examine if a
smaller adjustment can make a big difference for the operators without costing Altec a larger
amount of money. This way, the operating environment will be more ergonomically suited,
without major readjustments of the single handle controller and find out if any OSHA 200
(injury and illness record keeping) forms have been filed.
A balanced technical solution for Altec would be to implement the second handle and perform a
follow up evaluation. Ideally, Altec would implement both the second handle as well as the
pistol grip controller.
VII. Future Work
There is still work to be done on the pistol grip design. The SolidWorks model presented by the
team does not fully take into account the interlock. It merely offers an ergonomic solution. Team
MD6 primarily focused on the ergonomics in terms of the controller and the force/strain loadings
on the muscles in this project. Additionally, EMG testing would vastly contribute to the validity
of the ergonomic solutions presented in this report.
I E 5 7 1 F i n a l E x a m | 25
VIII. References
[1]"Altec ISO-Grip Control System." Altec News and Articles. 5 Oct. 2013
<http://info.altec.com/articles/bid/242179/Altec-ISO-Grip-Control-System>.
[2]"ANSI/SIA A92.2-2009 Vehicle Mounted Elevating and Rotating Aerial Devices."
ANSI eStandards Store. 5 Oct. 2013
<http://webstore.ansi.org/RecordDetail.aspx?sku=ANSI%2FSIA+A92.2-2009>.
[3]Chaffin, Don B., Gunnar Andersson, and Bernard J. Martin. Occupational
biomechanics. New York: Wiley-Interscience Publication, 1999.
[4]Chaffin, Don B., Gunnar B. J. Andersson, and Bernard J. Martin. Occupational
biomechanics. New York: Wiley, 2006.
[5]"CSA C225-10 Vehicle-mounted Aerial Devices (Includes Update 1)." ANSI
eStandards Store. 5 Oct. 2013
<http://webstore.ansi.org/RecordDetail.aspx?sku=CSA+C225-10>.
[6]"Ergonomics." Ergonomics: OSH Answers. 5 Oct. 2013
<http://www.ccohs.ca/oshanswers/ergonomics/>.
[7]"Ergonomics." US Army Combat Readiness/Saftey Center. 5 Oct. 2013
<https://safety.army.mil/soh/OCCUPATIONALHEALTH/Ergonomics/tabid/561/Default
.aspx>.
[8]"Hand Tool Ergonomics." Ergonomics: OSH Answers. 06 Oct. 2013
<http://www.ccohs.ca/oshanswers/ergonomics/handtools/>.
[9]"IEC 61057 ED. 1.0 B: 1991 Aerial Devices with Insulating Boom Used for Live
Working." ANSI eStandards Store. 5 Oct. 2013
<http://webstore.ansi.org/RecordDetail.aspx?sku=IEC+61057+Ed.+1.0+b%3a1991>.
[10]"Pushing & Pulling." Ergonomics: OSH Answers. 5 Oct. 2013
<http://www.ccohs.ca/oshanswers/ergonomics/push1.html>.
[11]Strength Data for Design Safety. Phase I. Department of Trade and Industry, October
2000.
[12]Strength Data for Design Safety. Phase II. Department of Trade and Industry,
October 2000.
I E 5 7 1 F i n a l E x a m | 26
[13]"Tecnomatix." Assembly Planning and Validation: Siemens PLM Software. 06 Oct.
2013
<http://www.plm.automation.siemens.com/en_us/products/tecnomatix/assembly_plannin
g/index.shtml>.
[14]"Tecnomatix." Jack and Process Simulate Human: Siemens PLM Software. 5 Oct.
2013
<http://www.plm.automation.siemens.com/en_us/products/tecnomatix/assembly_plannin
g/jack/index.shtml>.
[15]Wickens, Christopher D., Sallie E. Gordon, and Yili Liu. An introduction to human
factors engineering. Upper Saddle River, NJ: Pearson Prentice Hall, 2004.
[16] Altec
[17] Dr. Jason Gillette, Associate Professor, Department of Kinesiology, Iowa State
University. Postdoctoral: University of Kentucky, Biomedical Engineering; Doctor of
Philosophy: Iowa State University, Biomedical Engineering, and Engineering Mechanics.
[18] Dr. Richard Stone, Associate Professor, Department of Industrial Manufacturing
Systems Engineering; Doctor of Philosophy: University of Buffalo – New York,
Industrial Engineering.
[19] Alex Renner, Doctor of Philosophy candidate, Iowa State University, Mechanical
Engineering and Human Computer Interaction.
[20] Dr. Gary Mirka, associate dean, Iowa State University. Doctor of Philosophy,
Industrial and Systems Engineering, Ohio State University.

More Related Content

Similar to IE571 Final Schnieders

Design and development of a load monitoring device for physical rehabilitation
Design and development of a load monitoring device for physical rehabilitationDesign and development of a load monitoring device for physical rehabilitation
Design and development of a load monitoring device for physical rehabilitationAlex Proulx
 
Experimental and numerical stress analysis of a rectangular wing structure
Experimental and numerical stress analysis of a rectangular wing structureExperimental and numerical stress analysis of a rectangular wing structure
Experimental and numerical stress analysis of a rectangular wing structureLahiru Dilshan
 
IRJET - Development of Pneumatic Exoskeleton Suit
IRJET - Development of Pneumatic Exoskeleton SuitIRJET - Development of Pneumatic Exoskeleton Suit
IRJET - Development of Pneumatic Exoskeleton SuitIRJET Journal
 
Design and Analysis of Chute System to obtain World Class OEE
Design and Analysis of Chute System to obtain World Class OEEDesign and Analysis of Chute System to obtain World Class OEE
Design and Analysis of Chute System to obtain World Class OEEijsrd.com
 
Aespire 6X Participant Guide (1).pdf
Aespire 6X Participant Guide (1).pdfAespire 6X Participant Guide (1).pdf
Aespire 6X Participant Guide (1).pdfJUANRAMONMONCADABACA
 
Electronic pressure sensors used in aircraft
Electronic pressure sensors used in aircraftElectronic pressure sensors used in aircraft
Electronic pressure sensors used in aircraftLahiru Dilshan
 
IRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba Tool
IRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba ToolIRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba Tool
IRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba ToolIRJET Journal
 
Innova 3145 Ford OBD1 Code Reader User Manual
Innova 3145 Ford OBD1 Code Reader User ManualInnova 3145 Ford OBD1 Code Reader User Manual
Innova 3145 Ford OBD1 Code Reader User ManualTim Miller
 
How to design a machine?
How to design a machine?How to design a machine?
How to design a machine?swargpatel283
 

Similar to IE571 Final Schnieders (20)

Design and development of a load monitoring device for physical rehabilitation
Design and development of a load monitoring device for physical rehabilitationDesign and development of a load monitoring device for physical rehabilitation
Design and development of a load monitoring device for physical rehabilitation
 
Experimental and numerical stress analysis of a rectangular wing structure
Experimental and numerical stress analysis of a rectangular wing structureExperimental and numerical stress analysis of a rectangular wing structure
Experimental and numerical stress analysis of a rectangular wing structure
 
Accelerated Stress Testing
Accelerated Stress TestingAccelerated Stress Testing
Accelerated Stress Testing
 
IRJET - Development of Pneumatic Exoskeleton Suit
IRJET - Development of Pneumatic Exoskeleton SuitIRJET - Development of Pneumatic Exoskeleton Suit
IRJET - Development of Pneumatic Exoskeleton Suit
 
Ergo Report FULL PRESS
Ergo Report FULL PRESSErgo Report FULL PRESS
Ergo Report FULL PRESS
 
Vt training plc_1
Vt training plc_1Vt training plc_1
Vt training plc_1
 
Design and Analysis of Chute System to obtain World Class OEE
Design and Analysis of Chute System to obtain World Class OEEDesign and Analysis of Chute System to obtain World Class OEE
Design and Analysis of Chute System to obtain World Class OEE
 
Vt training plc_1
Vt training plc_1Vt training plc_1
Vt training plc_1
 
Abb technical guide no.10 revd
Abb technical guide no.10 revdAbb technical guide no.10 revd
Abb technical guide no.10 revd
 
Aespire 6X Participant Guide (1).pdf
Aespire 6X Participant Guide (1).pdfAespire 6X Participant Guide (1).pdf
Aespire 6X Participant Guide (1).pdf
 
Electronic pressure sensors used in aircraft
Electronic pressure sensors used in aircraftElectronic pressure sensors used in aircraft
Electronic pressure sensors used in aircraft
 
Anp011
Anp011Anp011
Anp011
 
Ssp 204
Ssp 204Ssp 204
Ssp 204
 
IRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba Tool
IRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba ToolIRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba Tool
IRJET - Ergonomic Assessment in Vehicle Assembly Line using Reba Tool
 
Innova 3145 Ford OBD1 Code Reader User Manual
Innova 3145 Ford OBD1 Code Reader User ManualInnova 3145 Ford OBD1 Code Reader User Manual
Innova 3145 Ford OBD1 Code Reader User Manual
 
630 project
630 project630 project
630 project
 
CEBD010100.PDF
CEBD010100.PDFCEBD010100.PDF
CEBD010100.PDF
 
K012556370
K012556370K012556370
K012556370
 
K012556370
K012556370K012556370
K012556370
 
How to design a machine?
How to design a machine?How to design a machine?
How to design a machine?
 

IE571 Final Schnieders

  • 1. I E 5 7 1 F i n a l E x a m | 1 Iowa State University Ames, Iowa IE 571 Occupational Biomechanics Single Hand Held Controller Ergonomic Evaluation Final Exam Thomas M. Schnieders 4 May 2015
  • 2. I E 5 7 1 F i n a l E x a m | 2 Table of Contents Table of Contents............................................................................................................................ 2 Table of Figures .............................................................................................................................. 3 List of Tables................................................................................................................................... 3 List of Appendices........................................................................................................................... 3 I. Executive Summary..................................................................................................................... 4 II. Introduction ................................................................................................................................. 5 III. Schedule ...................................................................................Error! Bookmark not defined. IV. Customer Requirements Specification...................................................................................... 6 Statement of Need .......................................................................................................................... 6 System Descriptions and Functions ............................................................................................... 8 Function Tree.................................................................................................................................. 8 Function Chart and Block Diagrams............................................................................................... 9 Operating Environment................................................................................................................. 11 Deliverables .................................................................................................................................. 12 V. Market Research...................................................................................................................... 12 VI. Global and Social Impacts....................................................................................................... 12 VII. Recommendations and Design Concepts for the Redesign ................................................. 13 System specification..................................................................................................................... 13 Key Technical Challenges ............................................................................................................ 13 Ergonomic Evaluation................................................................................................................... 14 Testing of controller ...................................................................................................................... 17 Ergonomic Improvements and Design Concepts......................................................................... 19 Mathematical Verification of the Redesign................................................................................... 22 Trade Studies................................................................................................................................ 23 VII. Future Work............................................................................................................................ 24 VIII. References ............................................................................................................................ 25
  • 3. I E 5 7 1 F i n a l E x a m | 3 Table of Figures Figure 1: CAD-model of the Single Hand Held Controller………………………………………7 Figure 2: Function Tree of the Single Handle Controller…………………………………………8 Figure 3: Functional Flow Chart for single hand held controller…………………………………9 Figure 4: Muscles of the Back…………………………………………………………………...15 Figure 5: Muscles of the Forearm………………………………………………………………..16 Figure 6: How the test stand was assembled…………………………………………………….16 Figure 7: The hand controller set together with the test stand…………………………………...17 Figure 8: The pistol grip concept………………………………………………………………...19 Figure 9: The forces affecting the arm from the existing model………………………………...20 Figure 10: The extra handle to counteract torque in the body…………………………………...20 List of Tables Table 1: Classification of force/torque for selection of manual control actuators……………….14 Table 2: Minimum recommended dimensions of manual control actuators……………………..14 Table 3: Results from the calculations…………………………………………………………...22 List of Appendices Appendix A: Customer Requirement Benchmarking Appendix B: ISO 9355-3: 2006 Appendix C: Matlab Code Appendix D: Body Part Discomfort Chart Appendix E: Borg CR10 Scale Appendix F: Force Recording Appendix G: New Handle Appendix H: Extra Handle Appendix I: Part 00001 Appendix J: Part 00002 Appendix K: Part 00003 Appendix L: Part 0004 Appendix M: Part 0005 Appendix N: Part 0006 Appendix O: Part 0007 Appendix P: Part 0008
  • 4. I E 5 7 1 F i n a l E x a m | 4 I. Executive Summary Included in this report is a project plan for the project “Single Hand Held Controller,” for IE 571, Occupational Biomechanics at Iowa State University. The project plan details statement of need, customer requirements, and market research. The project is for by Altec, a leading provider of products and services ranging from electric utility to contractor markets. Paul Zinnel and Chris Barnes will be the team’s primary contacts at Altec. The team will be advised by Dr. Mani Mina. The evaluation is on pilot pressure hand held controllers and will initially focus on the ergonomic standards research and evaluation. The report ends with an evaluation on full pressure hand held controllers, the design and building of a test platform, a redesign of the original controller and other suggestions for Altec. The purpose of this project is to find ergonomic standards that relate to single handle controllers and aerial devices, design and develop a test platform and method for testing Altec’s iso grip controllers, and evaluate if Altec’s controllers meet ergonomic standards. The reason for the project comes from high strain in the shoulder and arm on operators during two and three function movements. By analyzing, testing, and simulating these forces, an ergonomic evaluation will be completed and suggestions and recommendations for a redesign will be proposed. A redesigned prototype will be submitted which will meet the ergonomic standards.
  • 5. I E 5 7 1 F i n a l E x a m | 5 II. Introduction Ergonomics has become a topic of larger importance over the recent decades and is a significant aspect for individuals and companies in more than one way. Poor ergonomic conditions can cause more severe issues than one might think. Many workers are injured in the workplace due to incorrect ergonomic conditions, which usually consist of attritional wear due to incorrect movements, strains, and lifts. Ergonomics also affects the company in a larger degree, regarding the economic and productive aspects. An injury caused by work related conditions is a cost for the injured employee, company, and society. By reducing the risks for strain injury or attritional wear with better ergonomic standards and conditions at the job site, savings of resources for the company, employee, and society can occur. A company with good ergonomic conditions and products are more competitive and are more attractive as an employer. Altec, a company which was established over 80 years ago, delivers products and services in more than 100 countries worldwide. Their core values include putting the customer first, enjoyment of work, and quality. With this stated, their products need to meet good ergonomic conditions since they are used daily by their customers. One subject of ergonomic discussion is their single hand held controller used in aerial devices. Operators of the aerial devices use the single hand held controller during a work day, which could range in length from 1-8 hours per day. This requires that the controllers meet good ergonomic conditions in order to prevent injuries caused by the controller and ease utilization. In order to supply Altec an ergonomic evaluation of the single hand held controller and suggest a redesign, specific requirements have to be met.
  • 6. I E 5 7 1 F i n a l E x a m | 6 IV. Customer Requirements Specification Statement of Need Altec offers many different products such as digger derricks, pressure diggers, and ground pole drivers. However, the focus of the MD5 team will be on the aerial trucks. The aerial trucks are the units utilized for power line access. There are four main types of aerial trucks produced by Altec: the Non-Overcenter, the Overcenter; the Telescopic; and the Telescopic Articulating. The Non-Overcenter (Figure I) line of trucks has lift baskets that are capable of reaching up to 150 ft. The Overcenter can reach heights up to 93.3 ft. The Telescopic can reach heights up to 63 ft. Lastly, the Telescopic Articulating line can reach heights up to 64.8 ft. Figure 1: An example of a Non-Overcenter aerial truck The controller utilized to operate the lift basket of the aerial trucks is a trademark patent of the company. The controller is designed for one-arm operations, and there are two main types of controllers: full-pressure (Figure 2) and pilot-pressure (team MD5 will work with the full-pressure controller). Both controller types operate on a hydraulic system; however; the pilot-pressure controller has a secondary pressure system that serves as median between the user and the main
  • 7. I E 5 7 1 F i n a l E x a m | 7 hydraulic system. Thus, the hydraulic system is more efficient in delivering power to necessary functions. Figure 2: Side view of the controller Altec Industries have several different single hand held controllers to maneuver their products. Over the last few years there have been customer complaints about fatigue caused by their iso grip controllers, especially during two and three function movements that involve pulling the controller backwards and upwards at the same time. Altec desires to investigate the ergonomics surrounding the single handle controller and see whether it matches any ergonomic standards. If it does not fit ergonomic standards, Altec would like to be provided with an alternative design or improvements that could solve the problem and alleviate fatigue. Figure 3: CAD-model of the Single Hand Held Controller The problem is most prominent when operators use an upwards and backwards motion simultaneously. Additionally, the slow movement of the boom leads to more time required to
  • 8. I E 5 7 1 F i n a l E x a m | 8 hold the controller using the safety interlock system. It is also very important that the improvements do not include an electrical systems since the product is supposed to be used in an environment where electricity is not suitable and could be fatal. Additionally, Altec’s controller falls under the ANSI/SIA A92.2-2009 Vehicle-Mounted Elevating and Rotating Aerial Devices standard. The improvements or new design must also fit the dimensions of the controller box previously used. To determine whether the controller fits the ergonomic standards there must be a method for testing the forces on the controllers. This method will preferably be a physical model designed and manufactured which should be suitable for the six different controls. System Descriptions and Functions Function Tree Figure 2, below, demonstrates the two different operating systems of the single handle controller. The positioning system is the system causing fatigue, strain and uncomfortable movements of the arm and shoulder. The safety system is an essential system for the single handle controller and will have to have the same fundamental design in a redesign, due to its function and importance during utilization of the single handle controller. Figure 4: Function Tree of the Single Handle Controller
  • 9. I E 5 7 1 F i n a l E x a m | 9 Function Chart and Block Diagrams In Figure 5, below, the specific functions of the single hand held controller are shown. For a possible redesign and prototype, all these functions need to be considered, evaluated and retained. The functions of positioning the cubicle, see figure 3 below, of the aerial device can be divided in to the functions listed in Figure 4. Figure 5: Functional Flow Chart for single hand held controller The definitions of the functions are listed below: Move Up/Down: Move and position the cubicle upwards and downwards in a vertical direction by pulling/pushing the single hand held controller upwards/downwards. Move Back and Forward: This function on the single hand held controller is interconnected with the Move Up/Down function. While moving the cubicle from starting base position (horizontal position) to an upright vertical position, the joint connecting the two shafts will force a motion
  • 10. I E 5 7 1 F i n a l E x a m | 10 where the cubicle will move backwards and forwards while positioning into a vertical upright position. By pushing the single hand held controller forward/backward the cubicle will move forwards/backwards. Interlock: As a safety measure the single hand held controller has a lever which needs to be pressed in while operating the cubicle of the aerial device. If the interlock is not pressed in it is not possible to use the controller for any operations. The Move Up/Down function and Move Back/Forward can be combined into a two-function movement operation. This functionality is a customer requirement to retain during the project and all functions listed above are necessary to retain for a redesign of the single hand held controller. All three functions can also be combined into a three-function operation. This report will not focus on this. A detailed breakdown of the control interface is featured in Figures 6 - 11. The interlock linkage (Figure 7) is the safety feature that prevents the user from experiencing a self-induced controller response. Essentially, this means that the lift arms (also known as booms) can only move while the handle of the controller is squeezed. Pushing forward or backward on the controller activates the linkages featured in Figure 8. These motions raise and lower the bottom boom of the aerial truck. Pulling up and down on the controller activates the linkages featured in Figure 9. These motions raise and lower the upper boom. Tilling and twisting the controller activates the linkages in Figures 10& 11, respectively. These motions allow the user to rotate the lower boom in a circular pattern. The controller is also capable of performing compound movements. For example, the controller can be orientated so that the operator can raise the lower and upper booms and rotate the lower boom.
  • 11. I E 5 7 1 F i n a l E x a m | 11 Figure 6: Linkages for motion Figure 7: Interlock linkage Figure 8: Forward/ Backward control control linkage Figure 9: Up/ Down Control Figure 10: Tiller control Figure 11: Twist control linkage linkage linkage Operating Environment The single hand held controllers are used in the cubicle of the skylift of the aerial devices. The operators use the single hand held controllers during a work shift ranging from one to eight hours. The major part of the work is performed in an outdoor environment and the operators spend most of their shift in the cubicle. Depending on what type of work is performed, the single handle controller is used a number of different ways and the operator’s arm can be in different
  • 12. I E 5 7 1 F i n a l E x a m | 12 positions. One operator might only use the single handle controller to position the cubicle to get up to and down from the working site, while another operator might have a job which includes needing to position the cubicle several times during one work shift. Hence, the usage of the single handle controller differentiates depending on the tasks that need to be performed by the operator, leading to different working conditions for each operator. Some of the aerial devices are also used to work on power lines, which directly demands an isolated and non-electrical controller. Deliverables At the end of this project, a final report, recommendations, a set of ergonomic standards, and an analysis of Altec’s controllers will be presented with notes on how to improve the ergonomics of the controllers. A testing stand and testing procedure for force testing on the controllers will also be delivered to Altec. Additionally, if time permits, a prototype of the improved handle will be delivered either in CAD format or physical prototype. Force data and MATLAB calculations will be performed for the original controller and presented in the final report, and MATLAB estimations will be performed for the prototype. V. Market Research There are two primary systems to look at in the market – Altec’s ISO-Grip Control system and a scissor lift controller. A breakdown of their benchmarking may be seen in Appendix A, attached. Note that the customer requirement ranking is broken down as such: rank 9: “Very Important”, rank 3: “Moderately Important”, Rank 1: “Minor Important”. The option preference ranking is as follows: rank 9: Requirement “Strongly” Met, Rank 3: Requirement “Moderately” Met, and rank 1: Requirement “Barely” Met. VI. Global and Social Impacts The ergonomic evaluation will supply Altec with recommendations regarding ergonomic standards and suggestions for better ergonomic conditions for the single handle controller. With this Altec can chose to use the evaluation and improve the ergonomic conditions of the single
  • 13. I E 5 7 1 F i n a l E x a m | 13 handle controller. By doing so, Altec will be more competitive in the market with supplying aerial devices with better ergonomic controllers. Altec will be more attractive to customers, since good ergonomic conditions will improve the work environment and productivity of any company which is very beneficial for both Altec as for their customers who are leasing or buying the aerial devices. Consequently, it might lead to Altec creating new relations and gaining more customers, thus increasing its revenue and gaining a lead in the different markets Altec provides services and products in. An ergonomically improved single hand held controller also enables work possibilities and opportunities for elder operators. Avoiding fatigue, strain issues and complications as the operators get older allows them to work until retirement and the companies avoid having to pay for medical expenses. A better ergonomic control invites for a more pleasant and work friendly environment as an operator of the aerial devices. Operators will evade possible physical and mental pain due to injuries caused by a less ergonomic controller. In summary, more ergonomically fit single handle controllers and devices in general are preferred due to the many benefits to employees, employers, and leasing companies. VII. Recommendations and Design Concepts for the Redesign System specification There are specific functional structures which need to be considered for a possible redesign of the single hand held controller. Specific functions of the single hand held controller need to be retained to meet Altec’s requirements for the project and the controller. As stated in the Customer Requirement Specifications section, there are five main functions of the single hand held controller, which are to be retained in any redesign. Key Technical Challenges
  • 14. I E 5 7 1 F i n a l E x a m | 14 The key technical challenge for the design and function of the single hand held controller is that it cannot be electrical. Due to the Customer Requirements, the hand held controller is acquired to be entirely isolated and operated with nothing more than forces, torques, and hydraulics. For the redesigned single hand held control the same requirements have to be met. The key challenge would therefore be to design a hand held control with smoother operation without using electronics. Furthermore, the single hand held controller is to be locked and not moveable, therefore, another technical challenge is to make the handheld controller more ergonomic without being able to change the height of the control to suit the length of the operator. It is also to be fit into the box where it is positioned in the cubicle, which constrains the size of the controller. Ergonomic Evaluation The team was only able to locate one ergonomic standard that relates to Altec’s iso grip handle -- ISO 9355-3:2006 Ergonomic requirements for the design of displays and control actuators -- Part 3: Control actuators. The standard’s abstract is as follows: ISO 9355-3:2006 gives ergonomic requirements for, and guidance on, the selection, design and location of control actuators adapted to the needs of the operator, suitable for the control task in question and taking account of the circumstances of their use. It is applicable to manual control actuators used in equipment for both occupational and private use. The 40 page standard can be seen in Appendix B. Team MD 6 utilized four subject matter experts to locate the most relevant standard. Alex Renner, PhD candidate, was the team’s first point of contact. Thomas Schnieders worked with Mr. Renner in the Virtual Reality Applications Center. Mr. Renner has many years of experience in manufacturing and mechanical engineering working with ergonomics in the workplace. Mr. Renner gave the team a number of textbooks to reference and facilitated the 3D printing of the prototype handle. Dr. Jason Gillette was the team’s second contact. Dr. Gillette received his masters and doctorate at Iowa State University in Biomechanics and teaches courses on Biomechanics and injury
  • 15. I E 5 7 1 F i n a l E x a m | 15 prevention in the workplace. Dr. Gillette also gave the team a few text resources as well as a short list of things to consider while re-designing the controller. Dr. Gillette pointed the team to Dr. Gary Mirka and Dr. Rick Stone to help in the search of an ergonomic standard. Dr. Mirka and Dr. Stone work with standards on a regular basis. Additionally, Dr. Stone does research in ergonomics and biomechanics. Dr. Stone suggested the use of the ISO 9355-3:2006 standard and the three other subject matter experts agreed on the decision. The ISO standard details out suggestions for design and gives a standard of force values for control actuators in section 5.2.3 Task requirement c) – Classification of force/torque (force) (Table 1). Table 1: Classification of force/torque for selection of manual control actuators Additionally, the standard provides a listing for minimum dimensions of manual control actuators (section 8.2 of the standard). A copy of that data can be seen in the table below. Altec’s controller meets this standard. Table 2: Minimum recommended dimensions of manual control actuators
  • 16. I E 5 7 1 F i n a l E x a m | 16 Guidelines for single handle controllers have been evaluated and applied on the Altec’s pilot pressure single handle controller. The guidelines discuss size of handles, angles and positions of arm and body and how to best reduce forces, strain and fatigue on the body. There are some ergonomic standards and guidelines on how the handle should be modelled and the current handle was within acceptable range. The most common problem with handles is that they are either too big/small, stiff, awkwardly placed or slippery. The handle was at an acceptable size and not slippery, thanks to the Altec logo, and not too stiff. There was, however, a problem with the placement of the controller. Based on the ISO standard, as well as discussions with Dr. Stone and Dr. Gillette, the placement of the controller creates an unnatural wrist angle which can lead to strain and fatigue in the wrist, shoulder, and forearm. From the team’s discussions with Dr. Stone, Dr. Mirka, and Dr. Gillette, as well as repeated manual testing, the team noted that the stress and fatigue would be most prominent in the following muscles: the latissimus dorsi, the trapezius, the levator scapulae, the flexor retinaculum, the pronator quadratus, and the brachioradialis (see figures 4 & 5). Figure 4: Muscles of the Back
  • 17. I E 5 7 1 F i n a l E x a m | 17 Figure 5: Muscles of the Forearm Testing of controller The testing was done using a force gauge meter where strings were attached to the handle of the controller. The controller was positioned in a test stand that was developed. The test stand was then manufactured by Altec. The test stand consists of 4 parts that was assembled with bolts and nuts. Then the hand controller was attached with bolts and nuts to the test stand, as seen in Figure 6. The drawing files for the test stand can be seen in Appendix I through P, attached. Figure 6: How the test stand was assembled
  • 18. I E 5 7 1 F i n a l E x a m | 18 The test stand was then locked in position with c-clamps to make sure nothing but the controller itself would be able to move during the testing. The final set up for testing should look like figure 7, below. The test stand would be suitable for the EMG-testing as well as for the force gauge testing. Figure 7: The hand controller set together with the test stand The strings were then connected to the gauge meter and pulled from the approximate center of the controller’s handle until the controller reached its maximum movable distance. To make sure the controller moved its full range of motion, the team first pushed or pulled the controller to its full extent. The values the team were after were the minimum amount of force required for the controller to reach its maximum distance in each of the primary directions. To normalize the data, it was collected from three different individuals and an average was calculated. A larger sample size would have been preferable, however, the team is confident that the data would still average out to a very similar result. The highest value was 10.2 lbs or 45.37 N and the lowest value was 4.2 lbs or 18.68 N. These results made it possible to determine which of the controllers were the stiffest based on the average values and it was controller 970042561. The least stiff was controller 716-61949. The recorded forces may be seen in Appendix F. The accuracy of the measurements are not the best, but the average gives somewhat of a correct estimate since all of the independent measured forces was within an acceptable interval.
  • 19. I E 5 7 1 F i n a l E x a m | 19 Most of the forces fell within the average degree of requirements found in the ISO 9355-3 standard, this can also be seen in Table 2, above. For Altec’s iso-grip controller, the forces should lie in the low to negligible range found in the table, indicating that the controller could use a redesign to best fit within the ergonomic standard. Additional EMG data was to be collected to show which muscles were experiencing the greatest strain. EMG, or electromyography essentially measures the electrical impulses produced by skeletal muscles as a result of movement. The higher the amount of electrical potential generated by muscle cells, the higher the signal recorded. In other words, the more force required of the muscles, which can indicate strain and load bearing, the higher the output. Every individual’s musculature is essentially the same but there are slight differences. This difference can be normalized by comparing an individual’s EMG data for the original controller, coupled with the force data, against the same individual’s EMG and force data against the redesigned prototype. With the help of their subject matter experts a hypothesize was formed about which muscles would experience strain. Even though a total of fifteen user study participants were found, due to time constraints and lack of availability with Dr. Stone, the data was unable to be collected. This data would have shown clearer results, but since the mathematical model, see Mathematical Verification of Redesign, and the measured forces gives an estimation regarding whether the controllers fulfill the ergonomic standards or not. Ergonomic Improvements and DesignConcepts To be able to reduce the strain on the wrist, forearm, and shoulder the angle of the handle needed to be changed. There were different design concepts that would have improved the angle, but the final concept was to change the grip to a pistol grip, as seen in Figure 5. The redesigned handle may also be seen in Appendix G, the relevant SolidWorks files may be seen in the relevant folder on CyPoint. This design was chosen through the use of the ISO 9355-3 standard, the textbook references on biomechanics, and the recommendations of Dr. Stone and Dr. Gillette. Additionally, the team chose this concept because it would be the least expensive option,
  • 20. I E 5 7 1 F i n a l E x a m | 20 whereas other concepts involved replacing more than one part in each of the already existing controllers. Figure 8: The pistol grip concept The pistol grip concept changes the force distribution in the arm and back reducing the strain. The force required to hold in the interlock to be able to operate the controller is negligible and is therefore not considered to be a problem. In the original design for the iso grip controller, the wrist would be bent downward causing point T2 (see Figure 9, below) to swing out away from the body creating a torque in the elbow joint as well as in the wrist and shoulder. This created high strain in the levator scapulae and the supraspinatus. Additionally, fatigue could result in the triceps and trapezius from repeated usage. The pistol grip provides a much more natural movement reducing the strain in the levator scapulae, the supraspinatus, the latissimus dorsi, the trapezius, the flexor retinaculum, the pronator quadratus, and the brachioradialis. Furthermore, the fatigue in the triceps and trapezius is also reduced. I was hoping to be able to further back its findings with relevant EMG data.
  • 21. I E 5 7 1 F i n a l E x a m | 21 Figure 9: The forces affecting the arm from the existing model The second recommendation is an extra handle for the other arm, see Figure 10, attached to the cubicle. The extra handle may be seen in Appendix H.. The extra handle would help counteract the torque using the handheld controller which could potentially reduce strain and fatigue in the internal and external obliques and the latissimus dorsi. When pulling with a force F1, for example, there will be a clockwise torque in the body and this could be counteracted by applying a counter torque via the extra grip. Figure 10: The extra handle to counteract torque in the body The twist motion is very non-ergonomic according to Dr. Stone, especially when using the already existing grip. The best ergonomic solution would be to exclude the twist motion entirely. The muscles of the human body are optimal when movements are in line with the body.
  • 22. I E 5 7 1 F i n a l E x a m | 22 A combination of the pistol grip and extra handle would, theoretically, reduce the forces and torques applied on the joints and muscles to the low and negligible sections for degree of requirements. This combination keeps the body’s limbs in line allowing for peak performance with minimal force. A model of the redesigned prototype with the pistol grip was 3D printed using the Virtual Reality Applications Center’s Makerbot Replicator 2X to help affirm the change in ergonomics with a change in grip style. Mathematical Verification of the Redesign To evaluate the redesigned prototype in an ergonomic point of view a mathematical model was set up. The model is derived from Figure 9. By calculating the torque in three joints of the arm; the wrist, the elbow, and the shoulder it should be easy to see if the prototype has decreased the strain that is a result of the torque. It is assumed that the forces that is needed to operate the existing joystick, is also needed to operate the redesigned prototype. Meaning that the forces used in this model will be the measured forces from the testing and they will be constant. The lengths l1, l2 and l3 will also be kept constant in both cases. The input variables consists of the angles θ1, θ2 and θ3, which will vary between the existing controller and the prototype and has been measured during operation of both of them. The calculations were done in MatLab and may be seen in the attached Appendix C. The results from the calculations is ambiguous and shows that the torque is reduced in some of the joints with the redesign, but it also shows that it increases in some of the other joints, see Table 3. These calculations doesn’t show which of the two designs is the most ergonomic. However, Altec’s main customer complaints were about the two function movement that included the Pull Up and the Pull Backward move. During this specific move the torque has decreased with the redesign. The team still strongly believes the redesign is more ergonomic. The EMG data would help show the ergonomic difference based on muscle activity.
  • 23. I E 5 7 1 F i n a l E x a m | 23 Table 3: Results from the calculations Trade Studies For Altec, a new single handle control would certainly be a major investment with an uncertainty in profitability. The current single handle controllers have been in utilization since 2001 and all the aerial devices are equipped with either the pilot pressure single handle controller or a similar controller. Thus, leading to a difficult decision making on which ways would be the better balanced solutions for Altec and their customers. An entirely redesigned single handle control would be a tremendous expense, even to an established company like Altec. The time for redesigning, cost of production, replacing the current controllers and to educate the operators in how to use the new single handle control might be superfluous for Altec. Altec already has devoted and established customers, meaning that Altec might not be in a need to execute such an extensive transformation for the single handle controller used in the aerial devices. In order to pursue that kind of adjustment, the customer complaints have to more extensive and larger in number to prove the necessity of a redesign. An extended examination and complaint analysis has to be performed in order to understand and assess the complaints on pain, fatigue and injuries after using the single handle
  • 24. I E 5 7 1 F i n a l E x a m | 24 controller. The team recommends that Altec has the companies who are filing complaints have their workers fill out a Body Part Discomfort Chart (Appendix D) and a Borg CR10 Scale (Appendix E). One possibility for Altec and the customers is to apply some of the ergonomic recommendations in this report, such as implementing a supportive handle. By doing so, Altec can examine if a smaller adjustment can make a big difference for the operators without costing Altec a larger amount of money. This way, the operating environment will be more ergonomically suited, without major readjustments of the single handle controller and find out if any OSHA 200 (injury and illness record keeping) forms have been filed. A balanced technical solution for Altec would be to implement the second handle and perform a follow up evaluation. Ideally, Altec would implement both the second handle as well as the pistol grip controller. VII. Future Work There is still work to be done on the pistol grip design. The SolidWorks model presented by the team does not fully take into account the interlock. It merely offers an ergonomic solution. Team MD6 primarily focused on the ergonomics in terms of the controller and the force/strain loadings on the muscles in this project. Additionally, EMG testing would vastly contribute to the validity of the ergonomic solutions presented in this report.
  • 25. I E 5 7 1 F i n a l E x a m | 25 VIII. References [1]"Altec ISO-Grip Control System." Altec News and Articles. 5 Oct. 2013 <http://info.altec.com/articles/bid/242179/Altec-ISO-Grip-Control-System>. [2]"ANSI/SIA A92.2-2009 Vehicle Mounted Elevating and Rotating Aerial Devices." ANSI eStandards Store. 5 Oct. 2013 <http://webstore.ansi.org/RecordDetail.aspx?sku=ANSI%2FSIA+A92.2-2009>. [3]Chaffin, Don B., Gunnar Andersson, and Bernard J. Martin. Occupational biomechanics. New York: Wiley-Interscience Publication, 1999. [4]Chaffin, Don B., Gunnar B. J. Andersson, and Bernard J. Martin. Occupational biomechanics. New York: Wiley, 2006. [5]"CSA C225-10 Vehicle-mounted Aerial Devices (Includes Update 1)." ANSI eStandards Store. 5 Oct. 2013 <http://webstore.ansi.org/RecordDetail.aspx?sku=CSA+C225-10>. [6]"Ergonomics." Ergonomics: OSH Answers. 5 Oct. 2013 <http://www.ccohs.ca/oshanswers/ergonomics/>. [7]"Ergonomics." US Army Combat Readiness/Saftey Center. 5 Oct. 2013 <https://safety.army.mil/soh/OCCUPATIONALHEALTH/Ergonomics/tabid/561/Default .aspx>. [8]"Hand Tool Ergonomics." Ergonomics: OSH Answers. 06 Oct. 2013 <http://www.ccohs.ca/oshanswers/ergonomics/handtools/>. [9]"IEC 61057 ED. 1.0 B: 1991 Aerial Devices with Insulating Boom Used for Live Working." ANSI eStandards Store. 5 Oct. 2013 <http://webstore.ansi.org/RecordDetail.aspx?sku=IEC+61057+Ed.+1.0+b%3a1991>. [10]"Pushing & Pulling." Ergonomics: OSH Answers. 5 Oct. 2013 <http://www.ccohs.ca/oshanswers/ergonomics/push1.html>. [11]Strength Data for Design Safety. Phase I. Department of Trade and Industry, October 2000. [12]Strength Data for Design Safety. Phase II. Department of Trade and Industry, October 2000.
  • 26. I E 5 7 1 F i n a l E x a m | 26 [13]"Tecnomatix." Assembly Planning and Validation: Siemens PLM Software. 06 Oct. 2013 <http://www.plm.automation.siemens.com/en_us/products/tecnomatix/assembly_plannin g/index.shtml>. [14]"Tecnomatix." Jack and Process Simulate Human: Siemens PLM Software. 5 Oct. 2013 <http://www.plm.automation.siemens.com/en_us/products/tecnomatix/assembly_plannin g/jack/index.shtml>. [15]Wickens, Christopher D., Sallie E. Gordon, and Yili Liu. An introduction to human factors engineering. Upper Saddle River, NJ: Pearson Prentice Hall, 2004. [16] Altec [17] Dr. Jason Gillette, Associate Professor, Department of Kinesiology, Iowa State University. Postdoctoral: University of Kentucky, Biomedical Engineering; Doctor of Philosophy: Iowa State University, Biomedical Engineering, and Engineering Mechanics. [18] Dr. Richard Stone, Associate Professor, Department of Industrial Manufacturing Systems Engineering; Doctor of Philosophy: University of Buffalo – New York, Industrial Engineering. [19] Alex Renner, Doctor of Philosophy candidate, Iowa State University, Mechanical Engineering and Human Computer Interaction. [20] Dr. Gary Mirka, associate dean, Iowa State University. Doctor of Philosophy, Industrial and Systems Engineering, Ohio State University.