The document describes a waste incineration and energy recovery system manufactured by Hafner. The modular system consists of 3 main components: a rotary kiln, heat exchanger/boiler, and flue gas purification system. It can process between 1,000-25,000 tons per year. The system is highly flexible and can operate at different temperatures for different waste streams. It also has low investment and operating costs.
Introduction To Lamco Forest Products, Engineered WoodMelanie Cauchon
LAMCO FOREST PRODUCTS: Greener Engineered Woods
STRONG Design Values up to 2.0E in Exact Widths 2½"-16", Lengths 5’8"- 32’, in any 1/16" increments. Can substitute dimensional lumber, MSR and even LVL in Modular, HUD, Panel & on-site construction as JOIST, HEADER, BEAM, STRINGER; TRUSS, FLOOR & ROOF COMPONENTS;TALL STUDS up to 32'; 14% or less moisture content & LIGHTER;
STRONG Design Values (1.5E,1.6E,1.8E and 2.0E) for substitution up to MSR to 2.0E LVL strength. HIGHER SPANS than lumber
NO SPECIAL TOOL needed to drill/nail
Can be PRE-DRILLED and Precise End Trimmed
REDUCES on site WASTE, LABOR & COST
REDUCES WEIGTH & HEIGHT at shipping of modular/manufactured homes
DESIGN VALUES in most SOFTWARES of plate connectors
Good for FIRE RATED ASSEMBLY (using 1-hr fire rated HEXION adhesive)
The document discusses Carrier Performance Series humidifiers. It notes that overly dry winter air can cause health issues and humidifiers add comfort by putting moisture back in the air. The humidifiers are efficient and effective by allowing users to feel comfortable at lower thermostat settings, improving air quality and reducing static electricity. They are also durable with corrosion resistant casing and include a five-year limited warranty. The humidifiers have easy to clean treated pads and operate quietly through precision tuned fans and motors or furnace blowers.
This document provides guidelines for using Rack Air Containment Systems (RACS) with APC cooling units. RACS isolate the supply and return air streams within a rack to improve cooling efficiency. Key benefits include warmer intake temperatures, more predictable cooling, and the ability to isolate high-density racks. RACS components allow for retrofitting and contain either the rear or front of racks. Approved configurations specify ratios of racks to cooling units. System controls must set the cooling unit to RACS mode and configure supply air temperature and fan speed settings.
The document describes Nautica's Multiple Small Plate (MSP) dehumidification technology. MSP technology uses small plate heat exchangers and smaller compressors to pre-cool and partially dehumidify incoming air, allowing larger dehumidification capacity with 50% lower energy costs than conventional systems. Nautica offers MSP technology in air handling units and fanless modules for various indoor applications, including food processing, hospitals, schools, and more.
EnergyLogic produces waste-oil heating equipment including furnaces and boilers. Their products are designed to efficiently and reliably burn used oils for heating applications. The document provides specifications for several models including the EL200B boiler, which produces 200,000 BTUs and includes features like a fuel metering pump, integrated air compressor, and optional domestic hot water coil. Maintenance requirements are also outlined, such as cleaning the heat exchanger every 500 hours of operation.
This document discusses the thermal performance of concrete masonry. It covers utilizing thermal mass advantages, selecting insulation systems, addressing thermal bridging, and controlling air infiltration. Some key points include how thermal mass can decrease heating and cooling loads, how insulation selection depends on climate and design criteria, how thermal bridging can increase heat loss, and how air infiltration accounts for a large portion of energy use. Proper insulation strategies and air sealing are important to optimize thermal performance.
The document describes a waste incineration and energy recovery system manufactured by Hafner. The modular system consists of 3 main components: a rotary kiln, heat exchanger/boiler, and flue gas purification system. It can process between 1,000-25,000 tons per year. The system is highly flexible and can operate at different temperatures for different waste streams. It also has low investment and operating costs.
Introduction To Lamco Forest Products, Engineered WoodMelanie Cauchon
LAMCO FOREST PRODUCTS: Greener Engineered Woods
STRONG Design Values up to 2.0E in Exact Widths 2½"-16", Lengths 5’8"- 32’, in any 1/16" increments. Can substitute dimensional lumber, MSR and even LVL in Modular, HUD, Panel & on-site construction as JOIST, HEADER, BEAM, STRINGER; TRUSS, FLOOR & ROOF COMPONENTS;TALL STUDS up to 32'; 14% or less moisture content & LIGHTER;
STRONG Design Values (1.5E,1.6E,1.8E and 2.0E) for substitution up to MSR to 2.0E LVL strength. HIGHER SPANS than lumber
NO SPECIAL TOOL needed to drill/nail
Can be PRE-DRILLED and Precise End Trimmed
REDUCES on site WASTE, LABOR & COST
REDUCES WEIGTH & HEIGHT at shipping of modular/manufactured homes
DESIGN VALUES in most SOFTWARES of plate connectors
Good for FIRE RATED ASSEMBLY (using 1-hr fire rated HEXION adhesive)
The document discusses Carrier Performance Series humidifiers. It notes that overly dry winter air can cause health issues and humidifiers add comfort by putting moisture back in the air. The humidifiers are efficient and effective by allowing users to feel comfortable at lower thermostat settings, improving air quality and reducing static electricity. They are also durable with corrosion resistant casing and include a five-year limited warranty. The humidifiers have easy to clean treated pads and operate quietly through precision tuned fans and motors or furnace blowers.
This document provides guidelines for using Rack Air Containment Systems (RACS) with APC cooling units. RACS isolate the supply and return air streams within a rack to improve cooling efficiency. Key benefits include warmer intake temperatures, more predictable cooling, and the ability to isolate high-density racks. RACS components allow for retrofitting and contain either the rear or front of racks. Approved configurations specify ratios of racks to cooling units. System controls must set the cooling unit to RACS mode and configure supply air temperature and fan speed settings.
The document describes Nautica's Multiple Small Plate (MSP) dehumidification technology. MSP technology uses small plate heat exchangers and smaller compressors to pre-cool and partially dehumidify incoming air, allowing larger dehumidification capacity with 50% lower energy costs than conventional systems. Nautica offers MSP technology in air handling units and fanless modules for various indoor applications, including food processing, hospitals, schools, and more.
EnergyLogic produces waste-oil heating equipment including furnaces and boilers. Their products are designed to efficiently and reliably burn used oils for heating applications. The document provides specifications for several models including the EL200B boiler, which produces 200,000 BTUs and includes features like a fuel metering pump, integrated air compressor, and optional domestic hot water coil. Maintenance requirements are also outlined, such as cleaning the heat exchanger every 500 hours of operation.
This document discusses the thermal performance of concrete masonry. It covers utilizing thermal mass advantages, selecting insulation systems, addressing thermal bridging, and controlling air infiltration. Some key points include how thermal mass can decrease heating and cooling loads, how insulation selection depends on climate and design criteria, how thermal bridging can increase heat loss, and how air infiltration accounts for a large portion of energy use. Proper insulation strategies and air sealing are important to optimize thermal performance.
Filtration units include retro-fit filter combination units, diatomaceous earth filters, and cartridge filters. Retro-fit filter combination units consist of parts that install inside and outside the pool to incorporate pumps, filters, controls and other equipment. Diatomaceous earth filters are made of polyester and fibreglass with different flow rates and outlet sizes available. Cartridge filters provide efficient water filtration.
This document provides specifications for an alternator model C630 that produces 14 volts and up to 350 amps. It has a unique brushless construction for durability and long life. It also has high temperature bearings and insulation for use in hot engine compartments. Performance curves show its output and efficiency levels across different RPM levels.
GONKA, established as a limited company in 1986 in Ostim, Ankara, has become one of the leading firms in Heating - Cooling - Air Conditioning - Ventilating Installation, with the high performance and disciplined working mentality of Halil GONCU (Mechanical engineer, BS MS ITU, 1975) and Salih KADAYIFCIOGLU (Mechanical Engineer, BS GU, 1982) within more than 23 years for both manufacturing and contracting.
GONKA Company, has been continuing its activities, in its factory located in Sincan Organized Industrial Area, since 1996. GONKA manufactures its products related to Heating - Cooling - Air Conditioning - Ventilating Installation in its factory in an area of 10.000 m2 and equipped with the latest technology.
GONKA, which is continuing its activities through its technical and managerial staff in its modern Directorate General Building in Cetin Emec Boulevard, Ankara which it has moved in 2002, has been replaced "GONKA Air Conditioning Installation Construction and Trade Joint-Stock Company" by transforming into "joint-stock company" in 2003.
GONKA enforces its activity in Turkey By serving through its network consisted of Istanbul and Ankara Region Offices and maintenance-repair services firms. In regions other than these, GONKA offers contact and service through local offices and central maintenance-repair crews.
GONKA; has KnowHow, especially about the field of "Clean Room" technology, which requires sterility in operating theatres and air conditioning-ventilating systems of environments such as operas, theatres, auditorium buildings, television studios which require silence.
GONKA has created "model company" profile in air conditioning sector through both manufacturing or supply of devices and its disciplined approach in mechanical operations by succeeding a lot of projects within last 23 years. GONKA, which has focused on internto 32 countries and succeeded many projects in Middle-East, Asia and Africa countries by its powerful foreign trade departmentational projects in last 15 years, gave representations
This document summarizes the features of SmartBank Metal-Enclosed Power Capacitor Banks from Maysteel:
[1] The banks improve power factor in industrial, commercial, and utility applications, with ratings up to 30 MVAR in a single enclosure.
[2] They are available in both fixed and automatically switched designs up to 20 steps, for voltages from 2.4 kV through 34.5 kV.
[3] Key features include heavy-gauge steel enclosures, front and rear doors, integral control and protection systems, and meeting all relevant standards.
Guardian Eco Guard Pattern Anti Reflective Solar GlassSam Malty
Guardian Industries has developed EcoGuard Pattern AR glass to optimize sunlight transmission for photovoltaic module applications. The glass uses Guardian's high-performance EcoGuard Pattern glass combined with a specially designed anti-reflective coating to maximize sunlight energy capture. Testing shows EcoGuard Pattern AR can increase module output by up to 5% compared to uncoated glass. As a global manufacturer of glass and coatings, Guardian is committed to providing innovative solar energy solutions and optimizing customers' energy costs.
This document provides specification and application information for Nelson Type LT self-regulating heater cable. The cable uses a conductive polymer core that automatically adjusts heat output in response to temperature changes along its length. It has optional metal braids and overjackets for different applications. The cable is used for freeze protection and low-temperature maintenance of pipes and systems carrying fluids, chemicals, and more.
This document provides specifications for the BNP Double 65 Suction Blast Cabinet. The cabinet features two blast stations for cleaning, peening, deburring, or finishing parts. It has safety interlocks, maximum air flow to the blast gun, and durable steel construction. Popular accessories include adjustable gun mounts, vortex tubes, and filters.
This document summarizes the features and specifications of HiSUN thin film photovoltaic modules. The modules use a tandem junction structure of amorphous silicon and microcrystalline silicon to achieve high stability and efficiency capturing more of the solar spectrum. Key features include proprietary design for high reliability, microcrystalline layer for superior long-term stability and efficiency, and bypass diodes to ensure maximum output. Specifications include electrical output values, dimensions, weight, and operating conditions. HiSUN aims to be the leading provider of efficient and affordable thin film solar technology.
This brochure presents Vacon NXP liquid cooled AC drives. As no air ducts are required, these high power density AC drives are suitable for locations where air-cooling is difficult, expensive or impractical or where installation space is at a premium such as in heavy industries with harsh operating conditions like marine & offshore, pulp & paper, renewable energy and mining & metal. These AC drives have been exclusively designed for liquid-cooling and are available in the power range from 7.5 to 5300 kW and at 380-690 VAC supply voltages for both induction motors and permanent magnet motors.
This brochure presents Vacon NXP products for Common DC Bus systems. The product range comprises front-end units, inverter units and brake chopper units in the entire power range from 550 kW to 2200 kW. The drive components are built on proven Vacon NX technology and provide the ideal energy sharing solution for a multitude of power systems. Typical applications for regenerative DC bus systems include high-power process industries such as pulp & paper, steel, metal & mining and marine cranes, where the use of braking power is relatively high. Non-regenerative DC bus systems are cost effective solutions for smaller machines and production lines, which typically use less braking power.
The Galaxy VM is a highly efficient three-phase UPS system ranging from 160 kVA to 1000 kVA that provides power protection for medium data centers and facilities. It features up to 99% efficiency in various operating modes, flexible energy storage options, and easy installation, integration, and management. The Galaxy VM lowers energy costs through its high efficiency and integrates well into electrical, physical, and monitoring environments.
Galaxy VS is a highly efficient, modular 20-150 kW UPS system that provides power protection for critical infrastructure through increased availability and reduced operating costs. It offers 99% efficiency in patented ECOnversion mode to minimize total cost of ownership, and maximizes availability through modular N+1 redundancy and scalability options. Galaxy VS is well-suited for data centers, commercial buildings, healthcare facilities, and other critical applications.
The Vestas V112-3.0 MW wind turbine sets new standards with its 54.65 meter blades, allowing it to produce more energy from lower wind speeds. It builds on proven Vestas technology to deliver reliable performance and reduce downtime. New innovations in the permanent magnet generator and full-scale converter provide excellent grid support and optimum energy production over a wide range of wind speeds.
E+I Engineering provides a fully integrated busbar distribution system utilizing five product ranges: High Powerbar, Intelligent Medium Powerbar, Medium Powerbar, Cast Resin Powerbar, and Medium Voltage Powerbar. The system offers benefits like efficiency, flexibility, quality, cost savings, and reduced project timelines through a single supplier. Customers can access E+I Engineering's BIM library to incorporate specific busbar items into 3D project plans.
The document describes the A.O. Smith Cyclone Xi commercial gas water heater. It has taken water heater functionality, performance, and design to a new level with a broader line of high efficiency models ranging from 50 to 130 gallons. It features an intelligent control system, powered anodes for superior tank protection, and venting flexibility. The Cyclone Xi also has advanced glass lining technology and can be installed in multiples to serve high demand applications.
GIS substations use SF6 gas insulation and enclosures to provide compact, reliable power distribution in a space-efficient and environmentally-friendly manner. Key components include busbars, circuit breakers, disconnectors, earthing switches, and control cubicles. Advantages include reduced size, protection from weather, and no risk of fire or explosion. Disadvantages include higher costs and need for specialized maintenance of SF6 gas. Future trends aim to improve compactness, reduce maintenance needs, and control SF6 decomposition byproducts.
Active beams provide low maintenance cooling and heating through passive technology. They require low airflow which saves fan energy. During start-up, protective films must remain on beams until spaces are clean to prevent fouling. Commissioning involves carefully lowering secondary water temperatures, balancing primary airflow, and confirming water conditions to ensure proper operation. Active beams are a versatile solution that can be tailored for various space requirements with energy savings benefits.
The document discusses key factors to consider in power system design:
1) A system must be efficient, carry imposed loads without overheating, and maintain minimum voltage drops.
2) It should provide continuous supply and minimize interruptions if faults occur.
3) The system needs to be simple and easy to operate/maintain with low losses.
4) However, a perfect system would be too costly, so economics must be balanced - using resources efficiently without equating economy with cheapness.
1) The document discusses Siemens' SIVACON S8 low-voltage switchboard that combines maximum safety and an appealing design for efficient power distribution applications up to 7000 A.
2) It offers various installation systems, functions, connection positions, section widths, and busbar positions to provide flexibility. All details merge in shape and function to simplify power distribution.
3) Extensive testing ensures maximum operational and personnel safety, even under arcing conditions. This high level of safety sets new standards for low-voltage switchboards.
This document describes a 15kV dynamic volt/VAR compensator that can be used to help distribution grids accommodate increasing levels of distributed renewable energy resources like solar. It injects reactive current to help maintain voltage standards while enabling more distributed generation. Key benefits are increased hosting capacity for renewables and reduced voltage fluctuations and harmonics. It has autonomous and dispatchable control modes and can be installed along feeders or in substations.
The document summarizes the Thermo King UT-Series self-powered truck refrigeration units. The UT-800 and UT-1200 models (1) are designed for undermount applications on trucks and trailers. They offer benefits like low fuel consumption, smaller size and lighter weight, and easy and low-cost installation. Key features include an advanced TSR-2 controller, a state-of-the-art GreenTech engine, corrosion prevention coating, and capacities from 8500W to 11200W at 0°C.
Filtration units include retro-fit filter combination units, diatomaceous earth filters, and cartridge filters. Retro-fit filter combination units consist of parts that install inside and outside the pool to incorporate pumps, filters, controls and other equipment. Diatomaceous earth filters are made of polyester and fibreglass with different flow rates and outlet sizes available. Cartridge filters provide efficient water filtration.
This document provides specifications for an alternator model C630 that produces 14 volts and up to 350 amps. It has a unique brushless construction for durability and long life. It also has high temperature bearings and insulation for use in hot engine compartments. Performance curves show its output and efficiency levels across different RPM levels.
GONKA, established as a limited company in 1986 in Ostim, Ankara, has become one of the leading firms in Heating - Cooling - Air Conditioning - Ventilating Installation, with the high performance and disciplined working mentality of Halil GONCU (Mechanical engineer, BS MS ITU, 1975) and Salih KADAYIFCIOGLU (Mechanical Engineer, BS GU, 1982) within more than 23 years for both manufacturing and contracting.
GONKA Company, has been continuing its activities, in its factory located in Sincan Organized Industrial Area, since 1996. GONKA manufactures its products related to Heating - Cooling - Air Conditioning - Ventilating Installation in its factory in an area of 10.000 m2 and equipped with the latest technology.
GONKA, which is continuing its activities through its technical and managerial staff in its modern Directorate General Building in Cetin Emec Boulevard, Ankara which it has moved in 2002, has been replaced "GONKA Air Conditioning Installation Construction and Trade Joint-Stock Company" by transforming into "joint-stock company" in 2003.
GONKA enforces its activity in Turkey By serving through its network consisted of Istanbul and Ankara Region Offices and maintenance-repair services firms. In regions other than these, GONKA offers contact and service through local offices and central maintenance-repair crews.
GONKA; has KnowHow, especially about the field of "Clean Room" technology, which requires sterility in operating theatres and air conditioning-ventilating systems of environments such as operas, theatres, auditorium buildings, television studios which require silence.
GONKA has created "model company" profile in air conditioning sector through both manufacturing or supply of devices and its disciplined approach in mechanical operations by succeeding a lot of projects within last 23 years. GONKA, which has focused on internto 32 countries and succeeded many projects in Middle-East, Asia and Africa countries by its powerful foreign trade departmentational projects in last 15 years, gave representations
This document summarizes the features of SmartBank Metal-Enclosed Power Capacitor Banks from Maysteel:
[1] The banks improve power factor in industrial, commercial, and utility applications, with ratings up to 30 MVAR in a single enclosure.
[2] They are available in both fixed and automatically switched designs up to 20 steps, for voltages from 2.4 kV through 34.5 kV.
[3] Key features include heavy-gauge steel enclosures, front and rear doors, integral control and protection systems, and meeting all relevant standards.
Guardian Eco Guard Pattern Anti Reflective Solar GlassSam Malty
Guardian Industries has developed EcoGuard Pattern AR glass to optimize sunlight transmission for photovoltaic module applications. The glass uses Guardian's high-performance EcoGuard Pattern glass combined with a specially designed anti-reflective coating to maximize sunlight energy capture. Testing shows EcoGuard Pattern AR can increase module output by up to 5% compared to uncoated glass. As a global manufacturer of glass and coatings, Guardian is committed to providing innovative solar energy solutions and optimizing customers' energy costs.
This document provides specification and application information for Nelson Type LT self-regulating heater cable. The cable uses a conductive polymer core that automatically adjusts heat output in response to temperature changes along its length. It has optional metal braids and overjackets for different applications. The cable is used for freeze protection and low-temperature maintenance of pipes and systems carrying fluids, chemicals, and more.
This document provides specifications for the BNP Double 65 Suction Blast Cabinet. The cabinet features two blast stations for cleaning, peening, deburring, or finishing parts. It has safety interlocks, maximum air flow to the blast gun, and durable steel construction. Popular accessories include adjustable gun mounts, vortex tubes, and filters.
This document summarizes the features and specifications of HiSUN thin film photovoltaic modules. The modules use a tandem junction structure of amorphous silicon and microcrystalline silicon to achieve high stability and efficiency capturing more of the solar spectrum. Key features include proprietary design for high reliability, microcrystalline layer for superior long-term stability and efficiency, and bypass diodes to ensure maximum output. Specifications include electrical output values, dimensions, weight, and operating conditions. HiSUN aims to be the leading provider of efficient and affordable thin film solar technology.
This brochure presents Vacon NXP liquid cooled AC drives. As no air ducts are required, these high power density AC drives are suitable for locations where air-cooling is difficult, expensive or impractical or where installation space is at a premium such as in heavy industries with harsh operating conditions like marine & offshore, pulp & paper, renewable energy and mining & metal. These AC drives have been exclusively designed for liquid-cooling and are available in the power range from 7.5 to 5300 kW and at 380-690 VAC supply voltages for both induction motors and permanent magnet motors.
This brochure presents Vacon NXP products for Common DC Bus systems. The product range comprises front-end units, inverter units and brake chopper units in the entire power range from 550 kW to 2200 kW. The drive components are built on proven Vacon NX technology and provide the ideal energy sharing solution for a multitude of power systems. Typical applications for regenerative DC bus systems include high-power process industries such as pulp & paper, steel, metal & mining and marine cranes, where the use of braking power is relatively high. Non-regenerative DC bus systems are cost effective solutions for smaller machines and production lines, which typically use less braking power.
The Galaxy VM is a highly efficient three-phase UPS system ranging from 160 kVA to 1000 kVA that provides power protection for medium data centers and facilities. It features up to 99% efficiency in various operating modes, flexible energy storage options, and easy installation, integration, and management. The Galaxy VM lowers energy costs through its high efficiency and integrates well into electrical, physical, and monitoring environments.
Galaxy VS is a highly efficient, modular 20-150 kW UPS system that provides power protection for critical infrastructure through increased availability and reduced operating costs. It offers 99% efficiency in patented ECOnversion mode to minimize total cost of ownership, and maximizes availability through modular N+1 redundancy and scalability options. Galaxy VS is well-suited for data centers, commercial buildings, healthcare facilities, and other critical applications.
The Vestas V112-3.0 MW wind turbine sets new standards with its 54.65 meter blades, allowing it to produce more energy from lower wind speeds. It builds on proven Vestas technology to deliver reliable performance and reduce downtime. New innovations in the permanent magnet generator and full-scale converter provide excellent grid support and optimum energy production over a wide range of wind speeds.
E+I Engineering provides a fully integrated busbar distribution system utilizing five product ranges: High Powerbar, Intelligent Medium Powerbar, Medium Powerbar, Cast Resin Powerbar, and Medium Voltage Powerbar. The system offers benefits like efficiency, flexibility, quality, cost savings, and reduced project timelines through a single supplier. Customers can access E+I Engineering's BIM library to incorporate specific busbar items into 3D project plans.
The document describes the A.O. Smith Cyclone Xi commercial gas water heater. It has taken water heater functionality, performance, and design to a new level with a broader line of high efficiency models ranging from 50 to 130 gallons. It features an intelligent control system, powered anodes for superior tank protection, and venting flexibility. The Cyclone Xi also has advanced glass lining technology and can be installed in multiples to serve high demand applications.
GIS substations use SF6 gas insulation and enclosures to provide compact, reliable power distribution in a space-efficient and environmentally-friendly manner. Key components include busbars, circuit breakers, disconnectors, earthing switches, and control cubicles. Advantages include reduced size, protection from weather, and no risk of fire or explosion. Disadvantages include higher costs and need for specialized maintenance of SF6 gas. Future trends aim to improve compactness, reduce maintenance needs, and control SF6 decomposition byproducts.
Active beams provide low maintenance cooling and heating through passive technology. They require low airflow which saves fan energy. During start-up, protective films must remain on beams until spaces are clean to prevent fouling. Commissioning involves carefully lowering secondary water temperatures, balancing primary airflow, and confirming water conditions to ensure proper operation. Active beams are a versatile solution that can be tailored for various space requirements with energy savings benefits.
The document discusses key factors to consider in power system design:
1) A system must be efficient, carry imposed loads without overheating, and maintain minimum voltage drops.
2) It should provide continuous supply and minimize interruptions if faults occur.
3) The system needs to be simple and easy to operate/maintain with low losses.
4) However, a perfect system would be too costly, so economics must be balanced - using resources efficiently without equating economy with cheapness.
1) The document discusses Siemens' SIVACON S8 low-voltage switchboard that combines maximum safety and an appealing design for efficient power distribution applications up to 7000 A.
2) It offers various installation systems, functions, connection positions, section widths, and busbar positions to provide flexibility. All details merge in shape and function to simplify power distribution.
3) Extensive testing ensures maximum operational and personnel safety, even under arcing conditions. This high level of safety sets new standards for low-voltage switchboards.
This document describes a 15kV dynamic volt/VAR compensator that can be used to help distribution grids accommodate increasing levels of distributed renewable energy resources like solar. It injects reactive current to help maintain voltage standards while enabling more distributed generation. Key benefits are increased hosting capacity for renewables and reduced voltage fluctuations and harmonics. It has autonomous and dispatchable control modes and can be installed along feeders or in substations.
The document summarizes the Thermo King UT-Series self-powered truck refrigeration units. The UT-800 and UT-1200 models (1) are designed for undermount applications on trucks and trailers. They offer benefits like low fuel consumption, smaller size and lighter weight, and easy and low-cost installation. Key features include an advanced TSR-2 controller, a state-of-the-art GreenTech engine, corrosion prevention coating, and capacities from 8500W to 11200W at 0°C.
GONKA, established as a limited company in 1986 in Ostim, Ankara, has become one of the leading firms in Heating - Cooling - Air Conditioning - Ventilating Installation, with the high performance and disciplined working mentality of Halil GONCU (Mechanical engineer, BS MS ITU, 1975) and Salih KADAYIFCIOGLU (Mechanical Engineer, BS GU, 1982) within more than 23 years for both manufacturing and contracting.
GONKA Company, has been continuing its activities, in its factory located in Sincan Organized Industrial Area, since 1996. GONKA manufactures its products related to Heating - Cooling - Air Conditioning - Ventilating Installation in its factory in an area of 10.000 m2 and equipped with the latest technology.
GONKA, which is continuing its activities through its technical and managerial staff in its modern Directorate General Building in Cetin Emec Boulevard, Ankara which it has moved in 2002, has been replaced "GONKA Air Conditioning Installation Construction and Trade Joint-Stock Company" by transforming into "joint-stock company" in 2003.
GONKA enforces its activity in Turkey By serving through its network consisted of Istanbul and Ankara Region Offices and maintenance-repair services firms. In regions other than these, GONKA offers contact and service through local offices and central maintenance-repair crews.
GONKA; has KnowHow, especially about the field of "Clean Room" technology, which requires sterility in operating theatres and air conditioning-ventilating systems of environments such as operas, theatres, auditorium buildings, television studios which require silence.
GONKA has created "model company" profile in air conditioning sector through both manufacturing or supply of devices and its disciplined approach in mechanical operations by succeeding a lot of projects within last 23 years. GONKA, which has focused on internto 32 countries and succeeded many projects in Middle-East, Asia and Africa countries by its powerful foreign trade departmentational projects in last 15 years, gave representations
GONKA, established as a limited company in 1986 in Ostim, Ankara, has become one of the leading firms in Heating - Cooling - Air Conditioning - Ventilating Installation, with the high performance and disciplined working mentality of Halil GONCU (Mechanical engineer, BS MS ITU, 1975) and Salih KADAYIFCIOGLU (Mechanical Engineer, BS GU, 1982) within more than 23 years for both manufacturing and contracting.
GONKA Company, has been continuing its activities, in its factory located in Sincan Organized Industrial Area, since 1996. GONKA manufactures its products related to Heating - Cooling - Air Conditioning - Ventilating Installation in its factory in an area of 10.000 m2 and equipped with the latest technology.
GONKA, which is continuing its activities through its technical and managerial staff in its modern Directorate General Building in Cetin Emec Boulevard, Ankara which it has moved in 2002, has been replaced "GONKA Air Conditioning Installation Construction and Trade Joint-Stock Company" by transforming into "joint-stock company" in 2003.
GONKA enforces its activity in Turkey By serving through its network consisted of Istanbul and Ankara Region Offices and maintenance-repair services firms. In regions other than these, GONKA offers contact and service through local offices and central maintenance-repair crews.
GONKA; has KnowHow, especially about the field of "Clean Room" technology, which requires sterility in operating theatres and air conditioning-ventilating systems of environments such as operas, theatres, auditorium buildings, television studios which require silence.
GONKA has created "model company" profile in air conditioning sector through both manufacturing or supply of devices and its disciplined approach in mechanical operations by succeeding a lot of projects within last 23 years. GONKA, which has focused on internto 32 countries and succeeded many projects in Middle-East, Asia and Africa countries by its powerful foreign trade departmentational projects in last 15 years, gave representations
www.gonka.com.tr
GONKA, established as a limited company in 1986 in Ostim, Ankara, has become one of the leading firms in Heating - Cooling - Air Conditioning - Ventilating Installation, with the high performance and disciplined working mentality of Halil GONCU (Mechanical engineer, BS MS ITU, 1975) and Salih KADAYIFCIOGLU (Mechanical Engineer, BS GU, 1982) within more than 23 years for both manufacturing and contracting.
GONKA Company, has been continuing its activities, in its factory located in Sincan Organized Industrial Area, since 1996. GONKA manufactures its products related to Heating - Cooling - Air Conditioning - Ventilating Installation in its factory in an area of 10.000 m2 and equipped with the latest technology.
GONKA, which is continuing its activities through its technical and managerial staff in its modern Directorate General Building in Cetin Emec Boulevard, Ankara which it has moved in 2002, has been replaced "GONKA Air Conditioning Installation Construction and Trade Joint-Stock Company" by transforming into "joint-stock company" in 2003.
GONKA enforces its activity in Turkey By serving through its network consisted of Istanbul and Ankara Region Offices and maintenance-repair services firms. In regions other than these, GONKA offers contact and service through local offices and central maintenance-repair crews.
GONKA; has KnowHow, especially about the field of "Clean Room" technology, which requires sterility in operating theatres and air conditioning-ventilating systems of environments such as operas, theatres, auditorium buildings, television studios which require silence.
GONKA has created "model company" profile in air conditioning sector through both manufacturing or supply of devices and its disciplined approach in mechanical operations by succeeding a lot of projects within last 23 years. GONKA, which has focused on internto 32 countries and succeeded many projects in Middle-East, Asia and Africa countries by its powerful foreign trade departmentational projects in last 15 years, gave representations
www.gonka.com.tr
The companies of Altra Industrial Motion offer many critical drivetrain products utilized in renewable energy applications including brakes, power packs, geared motors, couplings, shaft locking devices and linear actuators.
Energy & Environmental Design Approach Speculative Lab Buildinggreenbauer1
This document provides an overview of the design approach for a speculative LAB building to optimize energy efficiency and sustainability. Key aspects include:
1. The building layout is 50% office and 50% open LAB space.
2. HVAC design utilizes active chilled beams with roof top AHUs and a high temperature chilled water system.
3. For labs, options include CAV, VAV, or high performance hoods. East-west glazing utilizes electrochromic windows for solar control.
Green Constitutes provides renewable energy products and services including wind turbines, solar panels, energy management systems, and energy auditing. Their wind turbines use counter-rotating blades to efficiently capture energy even at low wind speeds. They also offer vertical axis wind turbines suitable for urban areas. Green Constitutes assists with developing wind farms and provides long term technical and commercial management of wind plants. In addition to renewable products, their energy management systems and auditing services help customers optimize energy efficiency and reduce costs and emissions.
1. CI/SfB
56.83 X
Vision
RADIANT TUBE HEATING SYSTEMS
2. Vision
RADIANT TUBE HEATING SYSTEMS
Introduction Features Model Range
Renowned for its pioneering track record, New advanced burner technology There are two Vision ranges:
AmbiRad, Europe’s leading supplier of • Choice of burner ratings from 15 to 50kW • The standard VS range, which is available
radiant tube heating systems, has yet again depending on model type in U tube, single linear and double linear
raised the industry standard in terms of • All units are CE approved models, can be mounted in linear or
innovation and technical performance. U tube herringbone configurations
• NOx emissions as low as 52ppm on certain
The range of high efficiency Vision radiant models – 40% lower than standard radiant • The high efficiency VSX range, with
tube heaters delivers exceptional heater recuperative heat exchanger, is available
performance in terms of efficiency and the • Combustion occurs entirely within the firing as a U tube model
potential to reduce energy costs. tube. Not only does this reduce the size VSA models are available on request
The foundation of this development is a and weight of the traditional burner control (aluminised reflectors with no end caps).
high efficiency advanced burner. housing but it also helps to reduce noise
All models can be roof or wall mounted.
levels (as quiet as 47 dB(A) 3m free field)
• New slim-line burner head provides a long
evenly distributed flame that dramatically
improves temperature distribution along the
entire length of the heater, delivering a
more even floor coverage
• The inclusion of a recuperative heat
exchanger on VSX models (patent
P308150GB), mounted adjacent to the
burner housing, significantly increases
thermal efficiencies up to 90% and
enhances radiant efficiency above 60%.
VS
VSLF
VSDL
VSX
3. Benefits
Easy to install and maintain Additional control at the touch Herringbone configuration
• On forced gas burner models all electrical of a button Herringbone systems are specifically
wiring is contained at one end of the
All models are compatible with AmbiRad designed to suit individual building
product, which is particularly time
‘SmartCom3’ control systems. SmartCom3 requirements; they can incorporate up
saving when installing single linear
(VSLF) heater models units incorporate a host of features such to ten U tube or linear heaters on one
as self-learning optimised start-up to ensure exhaust manifold. The exhaust manifold
• All units require straightforward annual
maintenance increased comfort and energy savings. may be terminated through the roof
or wall.
Optimum economy and
fuel savings
• The elimination of both distribution and
standby losses coupled with high
operational efficiencies at the point of use
enable fuel savings of up to 65% compared SmartCom3 Radiant black
control panel bulb sensor
with conventional heating systems
(Please refer to separate leaflet ‘SmartCom3
• Excellent radiant performance. More of the
Energy Management Control’ for full details.)
available heat generated is distributed to The particular benefits of herringbone
floor level thereby improving efficiency and systems are:
reducing energy consumption
• Optimised energy efficiencies
• High efficiency VSXO and VSO herringbone
• All units share a common internal flue
configurations are included on the
thereby raising efficiency within the
Government’s Energy Technology List and
building
may be eligible for Enhanced Capital
• Uniform heat distribution within the
Allowances (ECA)
space being heated
• Improved aesthetics and minimal risk
of water ingress – only one penetration
of the building is required to enable the
products of combustion to be expelled
• Universal application – they are ideal
for both new build and older premises
(in particular where penetration of an
asbestos roof is an issue)
• VSO Listed on Energy Technology List
4. Vision
RADIANT TUBE HEATING SYSTEMS
Specification
VSX model
Flueing Fresh air intake Burner
Units can be installed unflued or Fresh air can be ducted into the heat Burner ratings range between 20 and 50kW
individually flued (including concentric exchanger from outside the building to in 5kW increments. The new burner head
flues to minimise building penetrations). provide clean combustion air, required located within the firing tube leg provides a
when there are contaminates in the very long flame with even heat distribution.
atmosphere. NOx emissions are very low – as low as
52ppm on certain models.
Heat exchanger
Mounted adjacent to the burner housing.
Significantly increases thermal efficiencies up to
90% and enhances radiant efficiency above 60%.
(Patent P308150GB).
Control housing
Burner controls are mounted within a chassis
that incorporates hinged doors for ease of
access for commissioning and maintenance.
Tube finish
CALCOAT® tubes – a high technology process
that applies a tough, dense, highly emissive
surface both inside and out that eliminates the
need for painting. As a result CALCOAT®
ensures a long lasting surface that will not rust
or flake, protects welds and maintains the
highest of emissivity factors throughout the
entire life of the heater.
5. Standard radiant heater AmbiRad Vision (VSX)
Burner Burner
Burner
AmbiRad Vision improves temperature distribution along the entire
length of the heater
Turbulators
Stainless steel spiral turbulators optimise
tube temperatures by ‘scrubbing’ the flue
gases against the tube surface, maximising
heat transfer and increasing radiant efficiency.
6. Vision
RADIANT TUBE HEATING SYSTEMS
Radiant Heating Universal Application Vision Applications
Working in the same way as the sun, radiant Radiant heating has traditionally been • Aircraft hangars
heat warms all solid objects and surfaces predominant in industrial and commercial • Automotive workshops and showrooms
in its path through electromagnetic waves. buildings, especially where there are large, • Factories
Being mounted overhead, AmbiRad radiant high bay areas or where there are a high
• Retail outlets
heaters produce infrared heat that is directed number of air changes within the environment.
downwards to low level by a reflector. • Sports arenas and halls
Vision has been developed with these
• Warehouses
Infrared energy passes inertly through markets in mind and with a view to making
the air, dissipating as heat upon contact radiant heating truly competitive within new • Workshops
with people and surfaces thus creating a smaller industrial and commercial buildings.
comfortable, all-round radiant warmth at
Its application is universal including
lower air temperature. This reduces
environments with high air change, frequently
wasteful heating of empty space and makes
opened doors, or where there is a need for
substantial energy savings over conventional
zonal heating in very large premises.
boiler and air systems.
The highly efficient performance of Vision
provides greatly reduced running costs and
improved capital payback, setting new
industry standards.
Enhanced Capital Allowances (ECA)
The Government’s Enhanced Capital
Allowance scheme actively encourages
industry and commerce to reduce energy
consumption by promoting the use of
energy efficient equipment. With radiant ™
efficiencies of above 60% and thermal
efficiencies of up to 90% (reducing fossil This symbol verifies that the product has been
independently assessed and qualifies for the
fuel consumption) a significant number of
ECA scheme, an upfront tax relief enabling
Vision models are included on this list, in
businesses that invest in energy-saving
particular VSX models equipment to claim 100% first-year capital
allowances against their taxable profits.
7. TECHNICAL DATA - All Models
Gas supply Connection 1/2 BSP internal thread
Electrical supply 230 volt 1 phase 50Hz
Current rating 1.0 amp max (inductive)
External fuse rating 3 amp external
Ignition Electronic programme start up with spark ignition
Exhaust flue – twin wall diameter 127 mm (5")
Vision Standard U Tube Models (induced burner) VSUT & VSAUT
Note: All technical details shown relate to both the VSUT & VSAUT models except for clearance distances as indicated
TECHNICAL DATA
Model VS15UT4 VS15UT VS20UT VS25UT VS30UT VS35UT VS40UT VS45UT VS50UT
Nominal gross heat input kW 15.8 15.0 19.5 23.5 29.5 36.0 40.0 44.0 48.0
Nominal gas rate per burner m3/h 1.5 1.4 1.9 2.3 2.8 3.4 3.8 4.2 4.6
Dimensional & weight data
Length mm 2219 3417 4142 5066 6029 5709 5709 7471 7471
Overall height mm 260 240 240 240 240 260 260 260 260
Overall width mm 675 500 500 500 500 675 675 675 675
Total installed weight kg 41 43 50 60 70 92 92 121 121
Recommended mounting height range For mounting heights above or below those specified contact AmbiRad Design Office
Horizontal m 4 to 5 4 to 5 4.5 to 7 5 to 8 5.5 to 9 6 to 10 6.5 to 11 7 to 12 7.5 to 13
Inclined / wall mounted m 3.5 to 4.5 3.5 to 4.5 3.5 to 5 4 to 5 4 to 6 4.5 to 6.5 5 to 7 5.5 to 8 6 to 9
MINIMUM CLEARANCE DISTANCES TO COMBUSTIBLE SURFACES
Model VS15UT4 VS15UT VS20UT VS25UT VS30UT VS35UT VS40UT VS45UT VS50UT
Above reflector VS models with end caps mm All models 180
Above reflector VSA models no end caps mm All models 280
Above burner & fan assembly flued mm All models 500
Beneath tubes mm 1500 1700 2100
To the sides mm 900 1000 1100
Horizontally from fan outlet unflued mm All models 1200
End of the heater to the wall mm All models 500
Vision Standard Heat Exchanger U Tube Models (forced burner) VSX
Model VSX20UT VSX25UT VSX30UT VSX35UT VSX40UT VSX45UT VSX50UT
Nominal gross heat input kW 20.0 25.0 32.0 36.0 40.0 44.0 49.5
Nominal gas rate per burner m3/h 1.9 2.4 3.1 3.4 3.8 4.2 4.7
Dimensional & weight data
Length mm 4047 5927 7692
Overall height mm All models 450
Overall width mm All models 746
Total installed weight kg 114 158 205
Recommended mounting height range For mounting heights above or below those specified contact AmbiRad Design Office
Horizontal m 4.5 to 7 5 to 8 5.5 to 9 6 to 10 6.5 to 11 7 to 12 7.5 to 13
Inclined / wall mounted m 3.5 to 5 4 to 5 4 to 6 4.5 to 6.5 5 to 7 5.5 to 8 6 to 9
MINIMUM CLEARANCE DISTANCES TO COMBUSTIBLE SURFACES
Model VSX20UT VSX25UT VSX30UT VSX35UT VSX40UT VSX45UT VSX50UT
Above reflector mm All models 100
Above burner & heat exchanger assembly mm All models 500
Beneath tubes mm 2300 2500
To the sides mm All models 1300
Horizontally from heat exchanger outlet unflued mm All models 1200
End of the heater to the wall mm All models 700
8. Vision Standard Linear Models (forced burner) VSLF & VSALF
Note: All technical details shown relate to both the VSLF & VSALF models except for clearance distances as indicated
Model VS15LF VS20LF VS25LF VS30LF VS35LF VS40LF VS45LF VS50LF
Nominal gross heat input kW 13.8 19.5 23.5 29.5 36.5 40.0 45.0 50.0
Nominal gas rate per burner m3/h 1.3 1.9 2.3 2.8 3.5 3.8 4.3 4.8
Dimensional & weight data
Standard length option Nominal metres 6 7 8 10.5 10.5 13.5 13.5 13.5
Total installed standard length weight option kg 43 49 53 72 103 126 126 126
Extended length option Nominal metres 8 10.5 10.5 12.5 13.5 16 16 16
Total installed extended length weight option kg 53 72 72 84 126 147 147 147
Overall height mm All models 390
Overall width mm 315 470
Recommended mounting height range For heights above or below those specified contact AmbiRad Design Office
Horizontal m 4 to 5 5 to 7 5 to 7 5 to 9 5 to 11 5 to 11 6 to 12 7 to 13
Inclined / wall mounted m 3.5 to 4.5 4 to 5 4 to 5 4 to 6 4 to 7 4 to 7 5 to 8 6 to 9
MINIMUM CLEARANCE DISTANCES TO COMBUSTIBLE SURFACES
Model VS15LF VS20LF VS25LF VS30LF VS35LF VS40LF VS45LF VS50LF
Above reflector VSLF models with end caps mm All models 150
Above reflector VSALF models no end caps mm All models 280
Above burner mm All models 500
Beneath tubes mm 1500 1700 2100
To the sides mm All models 750
Horizontally from heater outlet unflued mm All models 1200
End of the heater to the wall mm All models 500
Vision Standard Linear Models (induced burner) VSLI, VSALI, VSLH & VSALH
Note: For all dimensional, weight and clearance details please refer to Vision Standard Linear Forced burner section detailed above
Model VS15LI VS20LI VS25LI VS30LI VS35LI VS40LI VS45LI VS50LI
Nominal gross heat input kW 15.0 19.5 23.5 29.5 36.0 40.0 44.0 50.0
Nominal gas rate per burner m3/h 1.4 1.9 2.3 2.8 3.4 3.8 4.2 4.8
Vision Standard Linear Models (induced burner) VSDL & VSADL
Note: For clearance details please refer to Vision Standard Linear Forced burner section detailed above
Model VS15DL VS20DL VS25DL VS30DL VS35DL VS40DL VS45DL VS50DL
Total nominal gross heat input both burners kW 30.0 39.0 47.0 59.0 72.0 80.0 88.0 100.0
Total nominal gas rate both burners m3/h 2.8 3.8 4.6 5.6 6.8 7.6 8.4 9.6
Dimensional & weight data
Standard length option Nominal metres 12 14 16 21 21 27 27 27
Total installed standard length weight option kg 86 98 106 144 206 252 252 252
Extended length option Nominal metres 16 21 21 25 27 32 32 32
Total installed extended length weight option kg 106 144 144 168 252 294 294 294
Document reference number: GB/VS/124/0912
AmbiRad Limited Fens Pool Avenue
Brierley Hill West Midlands DY5 1QA
United Kingdom
Telephone: 01384 489700
Facsimile: 01384 489707
Email: marketing@ambirad.co.uk AmbiRad is a registered trademark of AmbiRad Limited. Because of continuous product
Website: www.ambirad.co.uk innovation, AmbiRad reserves the right to change product specification without due notice.