Regression analysis: Simple Linear Regression Multiple Linear Regression
Foamlink 944 r
1. Version 01/
944 03.09.2007
r
FoamLINK 944 r is a tape with a polyolefin foam as carrier.
The compressible foam carrier gives an good adhesion immediately after apllication even on rough and
slightly uneven surfaces.
ADHESION Steel I 35 I - - - - I - - - - I - - - - I - - - - I - - - - I
in accordance to AFERA 4001 Aluminium I 33 I - - - - I - - - - I - - - - I - - - - I - - -
Glass I 34 I - - - - I - - - - I - - - - I - - - - I - - - -
PMMA I 34 I - - - - I - - - - I - - - - I - - - - I - - - -
PVC I 29 I - - - - I - - - - I - - - - I - - - -
PP I 20 I - - - - I - - - - I
PE I 18 I - - - - I - - -
N / 25mm 10 15 20 25 30 35
COHESION 20º C I 75 I - - - I - - - I - - - I - - - I - - - I - -
in accordance to AFERA 4012 70º C I 20 I
N / 625mm2 20 30 40 50 60 70
01 / LINER
TAPECONSTRUCTION HDPE-liner, blue,
both sides siliconized, 125µm
02 / ADHESIVE
polyacrylate, class: r
coating weight: 90 g/m²
03 / CARRIER
01
PE-foam, 185 kg/m³
Color: black
02 Thickness: 0,8 mm
04 / ADHESIVE
03 polyacrylate, class: r
coating weight: 90 g/m²
Thickness
of tape 04
without liner The service temperature ranges from
approx. 1.0 mm - 40° to +70° short term even up to +90°
C C, C
STORAGE
This product should be stored at ambient temperatures of around 20° avoiding wide temperature fluctuations and direct sunlight. The storage environment
C,
should have a relative humidity of approx. 50%. In ideal storage conditions, the shelf life of this material will be approx. 12 months from the delivery date.
Within this 12 month period, when stored correctly, there should be no deterioration of the products published performance specification.
The values presented in this document have been determined by standard test methods and are average values that should not be used for specification or
approval purposes. Our recommendations for use are based on testing undertaken by BIOLINK and considered to be reliable. However, it is the
responsibility of the customer to undertake his own testing, in order to determine the products suitability for use. BIOLINK do not accept any reponsibility or
liability, directly or consequencially, for loss or damage caused as a result of their recommendations.
BIOLINK, Gesellschaft für Verbindungstechnologien mbH BIOLINK UK LTD
Jeschkenstrasse 20 · 82538 Geretsried,
Telefon 08171. 9396-26 · Telefax 08171. 9396-26 Tel: +44 (0)1327 704709 Fax: +44 (0)1327 706958
www.biolink-tapes.de · info@biolink-tapes.com www.biolink-tapes.de · info@biolink.co.uk