Crowcon manufactures fixed point gas detectors called TXgard & Flamgard Plus that reliably detect flammable, toxic, or oxygen gases. They have flexible output options and a low cost of ownership due to long life sensors, simple parts replacement, and non-intrusive calibration. The detectors come in three models - Flamgard Plus detects explosive levels of hydrocarbons, TXgard Plus detects toxic or oxygen gases with a choice of sensors, and TXgard-IS+ is an intrinsically safe model that can be used in Zone 0, 1, or 2 hazardous areas.
The Dräger X-am 2500® was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2, CO, NO2, SO2 and H2S. Reliable and fully mature measuring technology, durable sensors and easy handling guarantee a high degree
of safety with extremely low operating costs.
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest
possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can be configured to meet individual requirements.
The FLUXUS® flowmeter series includes a variety of transmitters
and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous areas.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
Draeger cataloger for fire & gas detection solution in region Australia, New Zealand, PNG & Pacific Islands. Please contact us for any further information.
United Electric TX200 Pressure TransmitterIves Equipment
The TX200 is a compact, rugged pressure transmitter utilizing ASIC technology to provide optimum sensor signal conditioning and temperature compensation of the sensor output. It is designed for process control industries worldwide and ideally suited for petrochemical and upstream oil and gas applications. The TX200 provides a cost-effective solution to using conventional process transmitters.
The xed range model tX200B is recommended for use where process pressure is consistent within the range and where physical access to the transmitter is limited or not required.
The eld adjustable model tX200a allows access to zero and span the transmitter. The transmitter may be spanned up to 5:1 and for ease of calibration, does not require a calibrated pressure source and can be calibrated in-place.
Cameron's CamCor™ PRO Series Coriolis flow meter features high-accuracy, shallow bow-shaped dual sensor tubes and is ideal for oilfield production applications. This industrial process-grade Coriolis flow meter offers high performance for accuracy, repeatability, wide flow range, low pressure loss, and safe design.
The Brooks® Ar-MiteTM is a reliable, low flow metal tube flowmeter with 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication. This model is a practical and economical approach to low flow rate indication for high pressure and difficult to handle fluids. Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
The Dräger X-am 2500® was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2, CO, NO2, SO2 and H2S. Reliable and fully mature measuring technology, durable sensors and easy handling guarantee a high degree
of safety with extremely low operating costs.
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest
possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can be configured to meet individual requirements.
The FLUXUS® flowmeter series includes a variety of transmitters
and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous areas.
H2scan’s 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan’s hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
Draeger cataloger for fire & gas detection solution in region Australia, New Zealand, PNG & Pacific Islands. Please contact us for any further information.
United Electric TX200 Pressure TransmitterIves Equipment
The TX200 is a compact, rugged pressure transmitter utilizing ASIC technology to provide optimum sensor signal conditioning and temperature compensation of the sensor output. It is designed for process control industries worldwide and ideally suited for petrochemical and upstream oil and gas applications. The TX200 provides a cost-effective solution to using conventional process transmitters.
The xed range model tX200B is recommended for use where process pressure is consistent within the range and where physical access to the transmitter is limited or not required.
The eld adjustable model tX200a allows access to zero and span the transmitter. The transmitter may be spanned up to 5:1 and for ease of calibration, does not require a calibrated pressure source and can be calibrated in-place.
Cameron's CamCor™ PRO Series Coriolis flow meter features high-accuracy, shallow bow-shaped dual sensor tubes and is ideal for oilfield production applications. This industrial process-grade Coriolis flow meter offers high performance for accuracy, repeatability, wide flow range, low pressure loss, and safe design.
The Brooks® Ar-MiteTM is a reliable, low flow metal tube flowmeter with 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication. This model is a practical and economical approach to low flow rate indication for high pressure and difficult to handle fluids. Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
Drager PointGard 2000 Series Gas Detection SystemFlow-Tech, Inc.
The Drager PointGard® 2000 series is a self-contained gas detection system for the continuous area monitoring of toxic or flammable gases in ambient air. PointGard® 2000’s rugged, water-resistant enclosure comes complete with a horn and strobes, a built-in power supply, and reliable DragerSensor®.
Magnetrol Guide Wave Radar Level Transmitter For Hygienic ApplicationsMiller Energy, Inc.
For hygienic applications, the transmitters are available with a 304 stainless steel housings designed specifically for use in facilities with the special requirements for the wetted and non-wetted materials, process connections and surface finishes of hygienic industries.
Similar to Crowcon TXgard IS Fixed Gas Detector - Spec Sheet (20)
Itron - Gas, Water & Heat Meters - Corporate Brochure
Crowcon TXgard IS Fixed Gas Detector - Spec Sheet
1. TXgard & Flamgard Plus
Fixed Point Gas Detectors
l Flexible output options
l Low cost of ownership
l Rugged and reliable
l Wide range of sensors
l Non-intrusive calibration
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
www.thorneanderrick.co.uk
2. When lives and property are at risk and you need gas detection
equipment that is totally reliable, you need Crowcon. For over 40
years Crowcon has been developing and manufacturing high quality
products with a reputation for reliability and technical innovation.
Crowcon fixed detectors have been proven in many arduous
environments, including oil and gas exploration, water treatment,
chemical plants and steel mills. They are however also chosen in
many other applications where reliability, dependability and lack of
false alarms are valued, for example in the automotive and aerospace
manufacturing sectors, on scientific and research facilities and in
high-utilisation medical, civil or commercial plants.
With 3 models available, we have a detector to suit your requirements.
The Flamgard and TXgard Plus range of detectors offer reliable detection of flammable, toxic or oxygen gases with a local display and
optional relays.
Choosing the fixed gas detector for your needs
Flamgard Plus:
Flamgard Plus is a Flameproof (Ex d), ATEX and UL certified flammable gas detector, which uses poison-resistant pellistors to detect
explosive levels of hydrocarbons, hydrogen and other flammable gases and vapours, including aviation fuel and leaded petrol vapours.
TXgard Plus:
TXgard Plus is a Flameproof (Ex d), ATEX and UL certified toxic or oxygen gas detector with local LCD display. A choice of sensors
are available enabling use in a wide range of applications, including water treatment, oil and gas exploration, chemical plants and steel
production.
TXgard-IS+:
TXgard-IS+ is a Intrinsically Safe (I.S.) toxic and oxygen gas detector with local LCD display. A wide choice of sensors is available for use
in a variety of applications. TXgard-IS+ is ATEX certified for use in Zone 0,1 or 2 hazardous areas, and also UL and cUL certified for use
in Division 1 or 2 hazardous areas.
TXgard & Flamgard Plus
Toxic and oxygen gas detector with display
TXgard-IS+TXgard PlusFlamgard Plus
3. Please see the back page for full technical specifications.
Low cost of ownership
Non-intrusive one man calibration
Long life sensors
Simple parts replacement
Flexible output options
4-20mA current sink or source
2 or 3 wire formats
Optional relays for alarm and fault
Rugged and reliable
TXgard Plus and Flamgard Plus are constructed using marine grade aluminium
with a stainless steel sensor housing
TXgard-IS+ is made from tough carbon loaded nylon
Ingress protection to IP65 as standard
Wide range of sensors
Choice of catalytic beads for a wide selection of flammable gases and vapours
Extensive range of electrochemical sensors for toxic gases and oxygen
Non-intrusive calibration
Calibration can be performed locally without the need for hot work permits
Local display and buttons enable calibration without opening the junction box
Works with a wide selection of control panels
Can be used for switching local alarms
Minimises operational down-time
Gas detector tailored to your requirements
Easy to operate and maintain
Keeps interuption to on-site activity to a minimum
Proven track record for operation in the harshest environments
4. P03019GB Issue 6 August 2013
TXgard & Flamgard Plus Specification:
Size
Weight
Enclosure material
Ingress Protection
Cable entries
Power
Operating temperatures
Humidity
Relays (optional)
Display
Calibration method
Electrical output
Terminals
Sensor type
Repeatability
Zero drift
Response time
Hazardous area zones
Approvals
EMC compliance
200 x 115 x 115mm
(7.9 x 6.1 x 6.1ins)
2.2kg (4.9lbs)
Junction box: Marine grade alloy
Sensor housing: 316 stainless steel
Flamgard Plus TXgard Plus TXgard-IS+
IP65
160 x 123 x 92mm
(6.3 x 4.8 x 4.5ins)
0.7kg (1.5lbs)
Junction box: Carbon loaded nylon
Sensor housing: ABD Plastic
2 x M20 or 1/2” NPT
10-30Vdc, 210mA max (relay version)
160mA max (non relay)
1 x M20 or 1/2” NPT with adaptor
8-32Vdc, 4-20mA loop-powered
-10o
C to +55o
C (14o
F to 131o
F) -10o
C to +55o
C (14o
F to 131o
F) * -20o
C to +55o
C (-4o
F to 131o
F) *
* Figures shown exclude the sensors - Please contact Crowcon for a full list of sensor operating temperatures
0-99% RH non-condensing 15 to 90% RH non-condensing
SPNO or SPNC contacts rated
30Vdc 1A (non-inductive load) for Alarm 1, Alarm 2, Fault
3-digit LCD back-lit display, LED status indicator
Via magnetically operated buttons
N/A
2-Line, 16 character LCD
Via push-buttons
2 wire 4-20mA
Suitable for up to 1.5mm2
cable Suitable for up to 2.5mm2
cable
Catalytic bead Electrochemical
+/- 2% FSD typically
+/-2% FSD, 6 months typically
T90 <15 seconds typically Contact Crowcon for a full list of sensor response times
Zone 1 or 2
Zone 0, 1 or 2
Division 1 or 2
(when connected via an isolation
device)
Ex II 1 G
Exia IIC T4 Ga
UL Class I, groups A, B, C and D
Ex II 2 G
Exd IIC T6 Gb
UL Class I Zone 1
EN50270, FCC, ICES-003
Gas Type
Acetylene (C2
H2
)*
Ammonia (NH3
)
Butane (C4
H10
)
Ethanol (C2
H5
OH)
Ethane (C2
H6
)
Ethylene (C2
H4
)
Hexane (C6
H14
)
Hydrogen (H2
)
LPG
Methane (CH4
)
Methanol (CH3
OH)
Pentane (C5
H12
)
Petrol vapor
Propane (C3
H8
)
Propanol (C3
H8
O)
Range Available:
Flamgard Plus
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
0-100% LEL
LEL (% vol.)
2.3
15
1.4
3.1
2.4
2.3
1.0
4
2
4.4
6
1.1
1.3
1.7
2.1
STEL (ppm)
35
200
0.5
0.3
-
10 (MEL)
3
10
1
0.2
-
0.06
0.2
1
LTEL (ppm)
25
30
-
0.1
-
-
1.8
5
1
-
-
0.02
0.1
1
Gas Type
Ammonia (NH3
)
Carbon monoxide (CO)
Chlorine (CL2
)
Chlorine dioxide CLO2
)
Hydrogen (H2
)
Hydrogen cyanide (HCN)
Hydrogen fluoride (HF)
Hydrogen sulphide (H2
S)
Nitrogen dioxide (NO2
)
Ozone (O3
)
Oxygen (O2
)
Phosgene (COCl2
)
Phosphine (PH3
)
Sulphur Dioxide (SO2
)
Range Available:
TXgard-IS+
50, 100, 1000ppm
250, 500ppm
5, 10, 20ppm
1 ppm
2000ppm, 50% LEL, 100% LEL
25ppm
10ppm
25, 50, 100, 200ppm
10ppm
1ppm
25% vol.
1ppm
2ppm
10, 20, 30ppm
Range Available:
TXgard Plus
-
100, 250, 500, 1000ppm
-
-
-
-
-
15, 20, 25, 50, 100, 200ppm
-
-
25%
-
-
-
LEL figures derived from EN60079-20-1:2010
*Acetylene option not available on UL certified version
STEL & LTEL figures are derived from the UK HSE document: EH40. Other thresholds may apply in countries outside the UK.
3 wire 4-20mA, sink or source
Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email: northernsales@thorneandderrick.co.uk
Website: www.heattracing.co.uk
www.thorneanderrick.co.uk