17. LIFTS • STANDARDS:-
1. HOTEL SHOULD PROVIDE ATLEAST 2 PASSENGER
LIFTS ( MANY MORE CAN BE INCLUDED TO
MAXIMIZE GUEST CONVINIENCE.)
2. 2. MINIMUM 1 NO. OF SERVICE LIFTS SHOULD BE
PROVIDED.
3. THE LIFT LOBBY SHOULD BE 1.5 -2 TIMES THE CAR
SIZE
4. FOR 13 PASSENGER LIFT IT SHOULD BE 2.5 X 1.9.
• PROVIDED/INFERENCE :-
1. THEY HAVE PROVIDED 4 PASSENGER LIFTS AND 4
SERVICE LIFTS
2. .2. FOR 13 PASSENGER LIFT THEY HAVE
PROVIDED 2.5X1.9.HENCE THEY HAVE FOLLOWED
STANDARDS.
LIFTS
18. FIRE SAFETY
FIRE SAFETY MEASURES
• STANDARDS:-
1. FOR BUILDING WHICH IS 15M- 30M HIGH FOLLOWING PROVISIONS SHOULD BE MADE.HOUSE REEL, WET RISER, DOWN COMER,
YARD HYDRANT, AUTOMATIC SPRINKLER SYSTEM, MANUALLY OPERATED FIRE ALARM SYSTEM & AUTOMATIC DETECTION ALARM
SYSTEM.
2. FIRE EXITS SHOULD BE PROVIDED AT EVERY 30M DISTANCES.
3. FIRE CONTROL ROOM SHOULD BE 4M X 4M.
4. UNDERGROUND WATER STORAGE CAPACITY SHOULD BE 100000 LTRS.
5. FIRE PUMP ROOM SHOULD BE 10M .IN LENGTH MIN.
• PROVIDED/INFERENCE:-
ALL THE ABOVE PROVISIONS ARE MADE IN THIS HOTEL.
21. CONCEPT :
THE ROOMS ARE BASED ON AN URBAN STUDIO
LOFT , MEANT FOR THE URBAN NOMAD WITH
AMENITIES AFFORDING GUESTS TO WORK
EFFECTIVELY OR TRAVEL COMFORTABLY WITH
BUSINESS COLLEAGUES.
OPEN PLAN SPACE WITHIN WHICH -
28M2 IS ZONED INTO A BEDROOM STUDY
CORNER,
RELAXATION CORNER,
NATURALLY-LIT SHOWER,
WALK-IN WARDROBE,
BATHROOM AND GLASS-ENCLOSED WC.
APPLIANCES AND CONVENIENCES OF A
TELEVISION, MINI-BAR, MAGAZINE RACK AND
AV SYSTEMS ARE ALL BUILT INTO WALLS.
NATURAL LIGHT AND DESIGNED FOR SPACE
CONSERVATION.
THE ROOMS CARRY AN OPEN, LIGHT AND
LIFTED AMBIANCE.
THE BED AS A CENTRAL FEATURE BECOMES A
CIRCULATION ELEMENT, EVOKING SPATIAL
FLUIDITY.
ROOM - DETAILS
22. MATERIAL
• WORKMANSHIP DEFECTS EMBRACED –
RAW RUSTIC LOOK
• BUSH-HAMMER FINISH; ENHANCING OR
HIDE THE TEXTURE OF EXPOSED
CONCRETE
• IN PLACES WHERE CONC. IS
INAPPROPRIATE– STONE OR TIMBER
PANELING
• ‘FLUX LINES’ EMBEDDED IN CONCRETE
INTERIOR AND EXTERIOR – SYMBOLIZE
BRAND, AVOID/CONCEAL EXPANSION
JOINTS
• ALL LOCAL MATERIALS TO AVOID CARBON
EXPENDITURE
• GROUND PLANE BECOMES GREEN ROOF
• HIGHLY REFLECTIVE GLASS WITH DARK
AND LIGHT TINTED ONES – SAVE ENERGY
SERVICES:
• LINEN ROOM WHICH ACCOMMODATES 4
ROTATIONS OF CLOTHES
• SUPPORT KITCHEN – MAJOR STORAGE AND
PRELIMINARY CUTTING
• IN HOUSE DOCTOR – DOCTOR FOR ONE HOUR
AND ON ON-CALL
• DEPARTMENTS – DEAN – FINANCE – SALES –
FOOD AND BEVERAGE – LEARNING AND
DEVELOPMENT – SECURITY – FRONT OFFICE/
RECEPTION
• LT/HT, HVAC IN THE HUGE MACHINERY ROOM
IN THE BASEMENT.
• _____ FIRE EXITS
• WASTE WATER TREATMENT ROOM
WATER USAGE
• BASEMENT – 3 TANKS • ROOF – 7 TANKS • 150L/C/D • 9
MATERIALS AND SERVICES
23. SUSTAINABLE MEASURES
• WATER SAVINGS INITIATIVES
– 80% USE OF RECYCLE WATER WITHIN
HOTEL PREMISES I.E. IRRIGATION,
FLUSHING AND COOLING TOWERS
– FLOW CONTROL DEVICE INWATER TAPS
FOR GUEST ROOMS.
– TOUCH LESS SENSOR WATER TAPS IN
LOCKERS
ELECTRICAL• DG:-1. THEY HAVE USED 750 KVA CAPACITY OF 2 NO.S 2. STANDARD SIZE
FOR DG ROOM SHOULD BE 10700MM(L) X 7700MM(W) X 6100MM(H).3. THEY HAVE
ADEQUATE AMOUNT OF SPACE FOR THIS ROOM.• TRANSFORMER:-1. THEY HAVE
PROVIDED 1000KVA CAPACITY OF TWO NO.S2. STANDARD SIZE FOR 1000KVA ROOM IS 5M
X 5M.3. THEY HAVE PROVIDED ADEQUATE SPACE FOR TRANSFORMER.• HT AND LT
ROOMS:-1. STANDARD ROOM SIZE FOR H.T SHOULD BE 4M X 4M.2. STANDARD LT ROOM
SIZE SHOULD BE 4M X 6M.3. THEY HAVE PROVIDE ADEQUATE SPACE FOR BOTH THESE
ROOMS. BACK OF THE HOUSE ANALYSIS :AC PLANT ROOM• THEY HAVE PROVIDED 3 NO.S
OF 250 T
• ENERGY SAVINGS
INITIATIVES
– MOTION SENSORS IN
PUBLIC AREA TOILETS
– TIMERS ON EXTERNAL
LIGHTING
– 5 KW SOLAR PANEL
COMMISSIONED LAST YEAR
WHICH SUPPLY FIRE EXITS
LIGHTS FOR ENTIRE HOTEL.
– IN PROCESS TO REPLACE 12
V, 50 W HALOGEN WITH 7
WATT LED IN GUEST ROOM .
40% LED’S HAS ALREADY
BEEN FIXED
ELECTRICALS AND SUSTAINABLE MEASURES
30. • THE BUILDING COMPRISES TWO BLOCKS, ONE ON EITHER
SIDE OF THE BUS STANDS:
TICKET OFFICE AND CUSTOMER SERVICES, WITH A
PETROL STATION AND SHOP ACCOMMODATED ROUND
THE BACK
COMMERCIAL SPACES AND OFFICES FOR THE TOWN
HALL
• MAIN USE COMPREHENDS THE NEW BUS STATION, PLACED IN
THE MOST PROMINENT POINT OF THE PLOT, NEXT TO THE
ROUNDABOUT, AND DIRECTLY VISIBLE FROM ALL POINTS.
LIKEWISE, A WIDE GREEN AREA IS PLACED NEXT TO THE
ROAD, TO EMPHASISE ITS PUBLIC ROLE.
• THE MAIN DECK HAS A VOID IN THE CENTRAL AREA TO
PROVIDE A KIND OF GARDEN, WHOSE PURPOSE IS TO
PROVIDE LIGHT, REFERENCE POINT AND TO SERVE AS A
BOUNDARY BETWEEN DIFFERENT USES AND SPACED.
• THE BUILDING'S MOST
PROMINENT FEATURE IS THE
HUGE CANOPY, WHICH IS
SUPPORTED BY ANGLED
WALLS AT THE REAR AND A
SLENDER COLUMN IN ONE
CORNER. THE REMAINING
CORNER REACHES OUT
UNSUPPORTED OVER THE BUS
STANDS.
• THIS FEATURE MAKES
THE STRUCTURE MUCH MORE
NOTICEABLE THAN
THE INDUSTRIAL BUILDINGS
THAT DOMINATE THE AREA,
HELPING TO PASSENGERS TO
EASILY LOCATE IT
BUS STATION
LOCATION : SANTA POLA, SPAIN
•ARCHITECTS: EMILIO VICEDO, MANUEL
LILLO
•AREA: 6010 M²
•THIS PROJECT IS SET AS AN URBAN
STRATEGY TO SOLVE THE PUBLIC USES PLOT
EXISTING IN THE SOUTH ACCESS TO SANTA
POLA TOWN, CONFORMING A KIND OF ‘DOOR
TO THE CITY’.
•THIS PROJECT HAD TO REALISE ITS NATURE
AS A LANDMARK, AND WAS SETTLED AS AN
ORGANIC AND UNIFORM ENSEMBLE OF
BUILDING PIECES AND SPACES.
INTRODUCTION