No Eguipments Featuresand Technical parameters
1 Mobile Digital X-RAY machines − Chụp tổng quát, chụp phổi, chụp cột sống, sọ não, chụp khớp.
− DR-Digital Radiography
− Max Voltage: 150kVp, current range: 10 mA to 300 mA, range time: 1 ms - 5s.
2 X-RAYGenerator for X-ray
machines
− Couple Structural of high-voltage module, oil free, ultra high frequency to 240 kHz;
used for X-RAY machine with the X-ray digital sensor plate Flat Panel, portable X-RAY
machine or other conventional X-RAY machine;
− Capacity: 30; 45; 50; 65; 80 kW;
− Voltage 40-125 kV or 40-150 kV, change 1 kV;
− Current 10 mA to 300 mA, 400, 500, 630, 800, 1000 mA
− Ray dose of 0.4 - 1000 mAs,
− Time 1ms - 10s.
3 Digital X-RAY machines (fixed)
4 Routine and High frequency
Mobile Digital X-RAY machines
5 Digital Panoramic dental X-ray
Machine
6 Portable Black and white
Doppler pulse ultrasound
machine.
− General examination, abdominal, obstetrics and gynecology, vascular...
− Frequency Ultrasonic: Multiple Frequency: 2 to 9 MHz
− Probe: linear (Linear) and a fan (Convex), micro convex, Transvaginal (option), - depth
survey: 2 -24 cm
− Display mode: B, B / B, B / M, M, B / D
7 Portable and trolley Color
Doppler pulse ultrasound
machine.
− General examination, abdominal, obstetrics and gynecology, urinary system,
digestive, cardiovascular...
− Frequency Ultrasonic: Multiple Frequency: 2 to 14 MHz.
− Probe: Can be used with a variety of probes with different frequency bands: Volume
probe, Liner, convex, phased array, micro convex, Transvaginal.
− Survey depth: 2-30 cm
1. Specialized Diagnostic Imaging Equipment
4.
No Eguipments Featuresand Technical parameters
1 5 parameters patient monitor show the measured parameters: ECG, RESP, SPO2, NIBP,
TEMP
2 6 parameters patient monitor (with
EtCO2)
show the measured parameters: ECG, RESP, SPO2, NIBP,
TEMP, EtCO2
3 6 parameters patient monitor show the measured parameters: ECG, RESP, SPO2, NIBP,
TEMP and blood pressure at measurement point
4 Obstetric Monitor monitoring uterine contractions (TOCO), fetal heart rate
(Fhr), blood pressure (NIBP) and the concentration of
oxygen (SPO2).
5 Measuring Device for saturation
concentration of oxygen in the blood
(SPO2)
6 EEG (EEG) 32/64 channels connected
with computer, data storage in
computer
7 Pocket ECG
2. Bio-signal and Monitoring Equipment
No Eguipments Featuresand Technical parameters
1 Electrical Syringe Pump - Applied for type syringe 10, 20, 30 and 60 mL.
- Set the pump speed range:
+ Syringe 10, 20, 30 mL: 0.1 - 300 mL/h (0.1mL / h step);
+ Syringe 60 mL: 0.1 to 1200 mL/h (0.1 to 999.9 mL/h:
0.1 mL/h step; 1000 - 1200 mL / h: 1 mL / h step)
2 Electrical low pressure vacuum
service Equipment
3 Mobile Oxygen Enrichment
Equipment
5l/min
4. Equipment for Medical Treatment
7.
No Eguipments Featuresand Technical parameters
1 Autoclave sterilizer 50/75 liter, 20 liter.
Center autoclave sterilization capacity
from 150 to 1000 liters
- Fully automatic control system, display steamed temperature ,
steamed time, drying time and cycle work procedure.
- Microprocessor control center.
- at least 5 automatically program installed
2 Sterilization cabinet different capacity:
53 liters; 80 liters; 100 liters; 120 liters;
160 liters; 200 liters; 420 liters
- fully automatically control by microprocessor,
- integrated intelligent program to control the temperature, time
of sterilization process with high accuracy.
3 Warmer cabinet with different capacity:
53 liters; 80 liters; 100 liters; 120 liters;
160 liters; 200 liters; 420 liters.
- fully automatically control by microprocessor,
- integrated intelligent program to control the temperature, time
of sterilization process with high accuracy.
4 Medical waste treatment system with
combination of water steam , microwave
technology and waste mill
Effective sterilization treatment by a combination of high pressure
of water steam and microwave conditions, additional milling
functions to reduce the volume of waste,
5 Medical wastewater treatment system
with AAO & MBR (anaerobic-anoxic-
aerobic) technology
Biotechnology combination of anoxic tank with the activated
sludge and membrane technology MBR, hight effective, small land
area, flexible. Capacity 150m3/day - 1000m3/day.
5. Disinfection, sterilization, and hospital waste treatment Equipment
8.
AMEKA X-VIEW MOBILEDIGITAL
General capture, lungs, spine, skull,
shooting match.
X-ray digital direct system (DR-
Digital Radiography).
Max voltage: 150kVp, current range:
10 mA to 300 mA, range time: 1 ms -
5s.
X-ray collimator
X-ray Tube Assembly Heating and
Cooling Curve
Amorphous Silicon Digital X-Ray
Imager
X-ray Generator
Digital
radiographic
X-ray
systems
9.
Display the measuredparameters: ECG, RESP,
SPO2, NIBP, TEMP.
ECG: measured 7 lead and displayed 2 leads at
the same time, heart rate ...
RESP: Breathing resistance.
SpO2: Measurement of oxygen saturation in the
blood concentration.
NIBP: Measured blood pressure intervention,
IBP: intervention blood pressure.
TEMP: temperature.
Measure respiratory rate and thoracic
impedance waveform.
European standards.
Standard published: Manufacturer 0001:2011 /
AMEC-MEDICAL
Multi parameter Patient monitors
10.
Syringe pump
Syringe thatis used in the case of
intravenous trace dose (low dose) and to
maintain a relatively long period of time.
Applied for type sy-line 10, 20, 30 and 60 ml.
Set the pump speed range:
+ Sy-line 10, 20, 30 mL: 0.1 - 300 mL / h
(0.1mL / h step)
+ Sy-line 60 mL: 0.1 to 1200 mL / h
(0.1 to 999.9 mL / h: 0.1 mL / h step)
(1000 - 1200 mL / h: 1 mL / h step)
Syringe pump
ECG
ECG 3,6,9, 12channels
• Large color touch-screen
• Alphanumeric keyboard and one-touch
operation
• Sleep mode to save energy and extend LCD life
• Automatic measurement and interpretation
tested with authoritative database
• Built-in rechargeable Li-ion battery
• Large ECG recordings storage capacity
• Support USB flash disk
• Extend printing once arrhythmia is detected
• Support external printer via USB port
• Grid printing on A4 size fax paper
• Support barcode scanner to simplify workflow
• Quick switch for gender and age groups
• Multi-format data export capability
• Data transmitting to PC via LAN/Wi-Fi
13.
Ultrasound black andwhite portable with pulse doppler
General examination, abdominal, obstetrics and
gynecology, vascular ...
Frequency Ultrasonic: Multiple Frequency: 2 to 9
MHz.
Types of probes: The use of 02 linear transducer
(Linear) and a fan (Convex), micro convex and
Transvaginal (option).
Depth survey: 2 -24 cm.
Display mode: B, B / B, B / M, M, B / D
Digital
diagnostic
ultrasound
systems
14.
Ultrasound color dopplersystem
Digital
diagnostic
ultrasound
systems
Hình minh họa
General examination, abdominal,
obstetrics and gynecology, urinary system,
digestive, cardiovascular ...
Frequency Ultrasonic: Multiple Frequency:
2 to 14 MHz.
Transducer: Can be used with a variety of
probes with different frequency bands:
Volume probe, Liner, convex, phased array,
micro convex, Transvaginal.
Survey depth: 2-30 cm.
Display mode: / B;/ 2B; / 4B; / M; / B / M; /
C; / PD; / PW; / CW; / B / C; / B / PD; / B /
PW; / B / CW; / B / C / M; / B / C / PW; / B / C
/ CW; / B / PD / PW; / B / PD / CW; / 3D
15.
1. Autoclave sterilizationcenters from 150 to 800 liter capacity.
2. Autoclave sterilizer 50/75 liter.
3. Autoclave sterilizer 20 liter
Features and specifications:
- Fully automatic control system, display steamed
temperature , steamed time, drying time and cycle
work procedure.
- Microprocessor control center.
- at least 5 automatically program installed
P1: (low temperature Steamed) Sterilization sorts
of interesting things to open as the temperature-
sensitive gloves, plastic, plastic tubular material
consumption.
P2 (Steamed high temperature): Sterilize the kind
of distress sealed mantle, general clothing,
underwear.
P3: Sterilize surgical instruments sealed or open.
P4: Sterilization of instruments and appliances
enclosed in a paper bag with coated insulation
standards.
P5: Sterilization of instruments sensitive to
temperature, pressure, vacuum pressure, things
to jamming sell out, poison bottles of all kinds.
Autoclave
sterilization
- Medicine cabinet2000 l, 3000 l; 4000 l
Features and specifications:
Medicine cabinet label RM-TS controller
completely automatically by the processor,
integrated program dedicated temperature
control, time. Island hot air fan system creates
uniform cabinet temperature, and separate
steam for drying, dried medicinal herbs most
effective.
- The drying chamber is made of stainless steel
SUS304, the shell is made of corrugated coating
is durable
- Oven is well insulated with high quality
vitreous, does not increase the room
temperature
Tủ
sấy
dược
liệu
Medicine cabinet
18.
Medical waste treatment
system:
(1)Solid Waste;
(2) Waste water treatment;
Currently, combustion technology is a new
trend because no toxic emissions, the
advantage of this technology is to develop
highly effective for infectious waste, does
not cause secondary pollution.
Derived from the use of technology
trends, the Company and the research unit
focused choice and perfect fit technology
and menu requirements of the health sector
to develop, provide treatment systems for
hospitals in the future.
Medical waste treatment system:
Option + steam microwave technology
combined Disposal equipment.
Technological advantages:
Effective sterilization treatment by a
combination of high pressure and microwave
conditions, upgrade / or additional
equipment, additional functions such as
cutting mill to reduce the volume of waste.
There are a number of different power levels
depending on the scale processing, to
achieve effective treatment by STAATT (level
III).
Solid Waste System in Hospital
19.
wastewater The
receiving
Circulatory flow
Anoxictank Oxic tank ) Membrane Bio
Reaction
Diagram AAO & MBR technology
Technology selection:
AAO technology options & MBR (anaerobic-
anoxic-aerobic) is a new biotechnology with a
combination of anoxic tank with the activated
sludge process and membrane technology
MBR.
Technological advantages:
This is modern technology, complete whole
from start to finish so for high efficiency
wastewater treatment, small land area,
flexible.
Solid Waste System in Hospital
E-METER
1
PHASE
E-METER 1 PHASE
Nominalvoltage 230V
Voltage 5(20)A,10(40)A, 20(80)A
Frequency 50Hz ± 2% (60Hz ± 2%
Frequency Accuracy Constant the to CL1 with the capacity and CL2
effects of reactive power
Meter constant 2500 imp/kWh – 3000 imp/kWh
Temp -100
C ~ 700
C
Allow moisture ≤95%
Power consumption of
voltage circuit
≤ 2W, 10VA
Power consumption of
current circuit
≤ 4VA
Backup battery voltage 3.6VDC, backup battery can work continuously for
two years in terms of storage and 10 years in
terms of the meter to be caught in the net.
22.
E-METER
3
PHASE
E-METER 3 PHASEs
Nominalvoltage /
phase
:
57 -240V (3 phases 4 wire)
100 - 415V (3 phases 3 wire)
Voltage :
Meters for direct measurement: 5(20)A,10(40)A, 20(80)A
Meters for indirect measurement:1(1.2)A, 5(6)A, 1(4)A,
5(20)A
Frequency :
50Hz ± 2% (60Hz ± 2% option)
Accuracy :
CL 0.5 (can be made up to the correct level CL0.2) at work
and CL2 with reactive power.
Meter constant :
5000 imp/kWh.
Temp
Storge Temp
:
:
-100
C ~ 700
C
-250C ~ 700C
Allow moisture :
≤95%
Real-time clock :
± 30s/months
Each voltage
circuit
:
max 10VA
Each current
circuit
:
max 1VA
Backup battery
voltage
3.6VDC, backup battery can work continuously for two
years in terms of storage and 10 years in terms of the
meter to be caught in the net.
23.
ULTILITES
TELECOMMUNICATION
MULTIPLE
ACCESS
ULTILITES TELECOMMUNICATION MULTIPLEACCESS
T-COMMAXX system include 3 multiplexer
families:
TC – 8200 PCM/PDH MULTIPLEXER TO PROVIDE
THE BASE INTERFACE FOR USER
TC – 8500 SDH MULTIPLEXER TO PROVIDE HIGH
SPEED DATA ACCESS SERVICES TO SDH
NETWORKS
TC – 8800 DXC MULTIPLEXER TO SUPPORT
MULTI-SERVICE PROVISION PLATFORMS (MSSP)
T-commaxx system are designed with the latest advance
semiconductor and transmission technologies, so it covers the full-
range applications from standard telephone access to high capacity
optical SDH accesses for utility communication
24.
FIRE
ALARM
SYSTEM
FIRE ALARM SYSTEM
T-SAFESYSTEM
TS-6200 Center Control System
TS-6210 Fire Alarm Control Panel (FACP)
TS-6400 Addressable Detector Series
TS-6410 Photoelectric Smoke Detector
TS-6420 Thermal Detector
TS-6430 Infrared Flame Detector
TS-6440 Ultraviolet Flame Detector
TS-6450 Manual Pull Station
TS-6600 Warning Series
TS-6610 Horn Device
TS-6620 Strobe Device
TS-6630 Announcement Device
TS-6800 Power Supply Series
TS-6810 AC-to-DC Converter
TS-6820 Extend Power Supply for Horn/Strobe Devices
25.
IP
PABX
AND
IP
PHONE
IP PABX ANDIP PHONE
• The full performance as conventional PBX switchboard.
• Supports 50 extensions, 20 concurrent calls.
• 8 FXO or FXS connection with post line (RJ11).
• 1 USB communication ports and MMC/SD card slot 1
• 1 WAN port, 1 LAN port speed of 10/100Mbps
• Based on the Asterisk
• Web configuration
• SIP/IAX server integration
• Supports Static/DHCP, PPPoE protocols
• Encoding/decoding (Codec): g.711-Ulaw, Alaw, g.711-g.726, g.729,
GSM, SPEEX
• Communicate with PSTN using Zap
• SIP/IAX protocol connection
• Zap protocol analog connection
• Large voicemail (Voice Mail Server)