1. Personal Information
Name Mohammed ansary mahamoud Mohammed Ali
Present
Position
Aswan high dam hydro power station electrical
Protection Engineer
Gender Male
Date of Birth 19101982
Place of Birth Aswan
Nationality Egyptian
Address Aswan –Sahary –Building 67
Martial Status Married
Military status Completed
E-mail Mohammed_ansary@yahoo.com
Home Tele +201113959819
Mobile Tele +201000330584
Education
Name Bachelor's degree in electric power engineering
Graduate June 2004
Faculty Faculty of engineering-Assiut university
City Assiut
Country Egypt
Specialization Power and machine electric engineering
General grade good
percentage 68.4%
project Magnetic field underneath laboratory three-phase transmission lines
Grade of project Excellent
skills
Languages Arabic (mother language) : excellent
English : good
Computer Windows, office, Internet,matlab,autocad and etap
2. Driving license Available
Special skills
Fast learning, good performance and hard working
-
1 Position
Aswan high dam hydro power plant station electrical
Operation Engineer
Company name Hydro plants generation company (HPGC)
Place Aswan – Egypt
Period From 20/04/2005 till 6/03/2011
Responsibilities • Control of frequency,voltage,active power, reactive power
of Egyptian electric network
• Management the control room of hydro power plant
• Using the distribution control system "DCS"in the control
of the all equipments of hydro power plant
• Responsible for monitoring and
operation of:
- synchrons generator
- power transformer
- auto transformer
- control panel
- measurement instrument
- HV circuit breaker
- HV network(500,220,132)KV
- MV distribution plant(6KV)
- LV distribution plant(400V)
- Fire fighting system for power units
-Operation of the main power units and auxiliary equipment
plant. Records/reports/takes corrective actions to correct
abnormalities.
• Directs the work of plant operators and shift helper.
• Ensures that routine checks and tests are carried out to
schedule.
• Able to carry out plant instructions and documentation.
• Assists in monitoring plant operation and performance and
takes a lead in identifying and rectifying operational
problems.
• Able to perform 12 hours shift work
2 Position
Aswan high dam hydro power plant station electrical
Protection Engineer
Company name Hydro plants generation company (HPGC)
Place Aswan – Egypt
Period From 7/03/2011 till now
Responsibilities • . Installing, pre-commissioning and commissioning, testing
3. and maintenance of the electromechanical, static, digital
and numerical protective relays (ABB, BBC, SIEMENS,
ELIN,..) for power generation station, HV substation and
HV transmission networks.
• Installing, pre-commissioning and commissioning, testing
and maintenance of the synchronization digital devices for
generation units and transmission lines (15.75, 220, 500
kV).
• Installing, precommissioning and commissioning, testing
and maintenance the control and protection circuits for LV
and HV Circuit Breakers (15.75, 220, 500 kV).
• Installing, pre-commissioning and commissioning, testing
and maintenance protection equipments for AC & DC
station services (11 kV, 6.6 kV, 0.4 kV AC, 220 V DC).
• Installing, pre-commissioning and commissioning and
testing voltage & current transformers.
• Use Hi-tech tools such, OMICRON CMC 356 test set and
Double F6150 test set.
• Using different standards (IEEE and ANSI, IEC,..).
• Power system analysis and fault studies.
• Short circuit calculations.
• Protective relays setting calculations.
• Cooperating with the rehabilitation companies which are
worked and interfacing the newer equipment with existing
DCS controller.
• Installing, pre-commissioning and commissioning, testing
and maintenance the cooling system for 501 MVA double
autotransformers and their numerical protective relays.
• Specify the technical specifications for some equipment
such as protective relays, chargers, testers (primary and
secondary). Finally, contract agreement to six 500 kV
circuit breakers and two power switching devices PSD.
• Installing, pre-commissioning and commissioning six 500
kV circuit breakers and two power switching devices PSD.
• Installing, pre-commissioning, commissioning and testing
two fault recorders REASON.
TRANNING ABROAD
From 22nd August2011 till 26th
August 2011 in MR GmbH,Germany
Participated in a product information course on MR tap-changer equipment
TRANNING INSIDE
4. From 3-14 June 2012 in Network Training Center Cairo
South Helwan
Basic Protection(p2(
REFRENCES
SENG. Mohammad Amr Awadelkarim
Chairman of board of Hydro Plants Generation
Company (HPGC)
High Dam west post office, Post Code 81521,
Aswan, Egypt.
Tel: +2 (097) 3480412, Fax: +2 (097) 3480463
ENG. Ahmed Saber Jabr
Chief of production sectors of Hydro Plants
Generation Company (HPGC)
High Dam west post office, Post Code 81521,
Aswan, Egypt.
Tel: +2 (097) 3480571, Fax: +2 (097) 3481000
ENG. Abdel Hafez Farghali Abdel Hafez
Manager of protection and testing department
High Dam Power Plant
High Dam west post office, Post Code 81521, Aswan, Egypt.
Tel: +2 (097) 3480571