TF1 Quick Reference Installation and Cleaning Guide
1. TF1 installation and cleaning
Quick Reference Guide
Lid tightening
www.fernox.com
For full instructions please refer to TF1 instructions.
In the event that the lid of the TF1
has been removed, ensure the lid
is fully re-tightened to the correct
position (lining up the embossed
line mark on both the lid and the
inlet/outlet port), using the spanner
provided (see diagram).
The TF1 unit does not need to be
disassembled for installation, cleaning
or servicing however if disassembled,
replace all appropriate seals for
example the lid collar/bleed valve
‘O’ rings, as good practice dictates
(spares are provided with product in
box). Additional Fernox TF1 Range
Seal and ‘O’ ring kit is available:
item number 59288.
Fast clean for TF1 Compact & TF1 Total Filter
– no need to remove lid
30 seconds
Close inlet and
outlet valves
Open outlet and
drain valves
Close drain valve,
replace magnet and
open inlet valve
Remove magnet
1 2 3 4
2. Fernox, Alent plc, Forsyth Road, Sheerwater, Woking, Surrey GU21 5RZ
Technical Helpline: +44 (0)870 870 0362 Email: sales@fernox.com
Fernox Total Filter TF1 is UK UK Patent No. GB2448232. Patent Applied For GB1213773.3A
www.fernox.com
Sealed system Open vented system
How to change the orientation for both the TF1
Compact TF1 Total Filter
Using a flat end screwdriver
in the recess shown, gently
lever the locking clip into
the ‘unlock’ position.
Pull the inlet/outlet port
approximately 3 mm away
from the body to allow
rotation to the required
position.
Push the inlet/outlet port
back towards the body of
the unit to prevent further
rotation.
Push the locking clip
securely back into the
‘lock’ position.
Flow
Flow Return
Return
Best position
Good position
Flow
Flow Return
Return
Best position
Good position