SlideShare a Scribd company logo
1 of 1
Download to read offline
14
COATING THICKNESS GAUGE
ARW-156“FN” For order 220121954
This compact Coating thickness gauge with built-in probe dual-tecnology “FN” is suitable for the measurement of coa-
tings (paint, zinc, plastic, rubber, ceramics, etc..) On both ferrous metals “F” (carbon steel, iron, cast iron, etc. .) and not-
ferrous metals“N”(stainless steel,aluminum,copper,etc.)..
This instrument is suitable for anyone who needs to measure a coating of paint or other coating easily and quickly with
a reasonable cost. You just place the probe on the surface to be measured and you can immediately determine the
thickness of the coating so identifying any repainting,inconsistency or unevenness of the surface tested.
Coating Thickness Gauge with built-in probe
Easy operation via“Menu”function (in English)
Built-in probe“FN AUTO”
Two selectable measuring modes:SINGLE (Single) CONTINUE (continued)
Two recording modes:DIRECT (direct measurement) and GROUP (measurement divided into max.4 groups
storable)
Display statistical data:AVG (average),MAX (maximum),MIN (minimum),NO.,(N ° readings),S.DEV (standard
deviation)
Zero calibration simple
Internal memory for 320 readings (80 for each group)
Alarm signal (High) and (Low)
USB interface and data management software
Measuring range 0-1250um
Resolution 0μm ÷-50μm 0,1μm 50μm ÷850μm 1μm than 10μm
Accuracy +/- (2 μm + 3% of reading) o +/- (0.1mils + 3% of reading)
Minimum thickness of the material
(substrate) 0.5mm
Memory 320 readings can be divided into max.4 batches
Size 120x62x32mm
Power supply Alkaline Batteries
Weight 175gr.
Supplied complete with USB cable,software for data management
case and user manual
TECHNICAL FEATURES
Ideal for any type of coating (paint,plastic,zinc,chrome,rubber,ceramics,etc..),on magnetic metallic bases“FE”(versions 8826
F - FN 8826). FN 8826 version also allows you to measure coatings (paint, plastics, anodizing, chrome, rubber, ceramics, etc..) of
non-magnetic metal bases“NFE”.
Coating thickness gauge
For coatings on ferrous ferrous metals (magnetic)
For coatings on ferrous and non ferrous metals (magnetic and not-magnetic)
ARW 8826 F
ARW 8826 FN
For order 220121334
For order 220121335
Thicknesses calibration standard in additional (values on request)
Excellent quality/price
Complete with separate probe with extension cable
appropriate for each type of flat or radiused surface
Easy and quick calibration with 4 thicknesses calibration stan-
dard (50 - 100 - 200 -500 μm)
Large LCD display with 4 digits
Low battery warning
Supplied with ABS case,probe (2 for FN 8826 version),Zero plate,4 thick-
nesses calibration standard and user manual.
Measuring range 0-1200 μm FE (FE-NFE version 8822)
Resolution 0,1 μm up to 100 μm - 1 μm up to 2000 μm
Accuracy ± 3% of reading or ± 2 μm
Operating temperature 0 + 50°C
Operating Humidity < 80%
Power supply 4 batterie 1,5 V (AA-UM3)
Size Instrument 161 x 69 x 32 mm
Size probe Ø 15 mm - H 55 mm
TECHNICAL FEATURES
Optional accessories for ARW 8826 F - ARW 8826 FN
www.measureinstruments.eu

More Related Content

Similar to Coating thickness gauge

Similar to Coating thickness gauge (9)

QS Metrology Private Limited, New Delhi
QS Metrology Private Limited, New DelhiQS Metrology Private Limited, New Delhi
QS Metrology Private Limited, New Delhi
 
Ultrasonic thickness gauge
Ultrasonic thickness gaugeUltrasonic thickness gauge
Ultrasonic thickness gauge
 
Bogen Technical LMSN
Bogen Technical LMSNBogen Technical LMSN
Bogen Technical LMSN
 
Introduction to Phased Array Using the OmniScan MX2 - Part One
Introduction to Phased Array Using the OmniScan MX2 - Part OneIntroduction to Phased Array Using the OmniScan MX2 - Part One
Introduction to Phased Array Using the OmniScan MX2 - Part One
 
TOFD PRO System
TOFD PRO SystemTOFD PRO System
TOFD PRO System
 
Advanced Probes for Austenitic and CRA Weld Inspection Webinar
Advanced Probes for Austenitic and CRA Weld Inspection WebinarAdvanced Probes for Austenitic and CRA Weld Inspection Webinar
Advanced Probes for Austenitic and CRA Weld Inspection Webinar
 
Magneto optics applications
Magneto optics applicationsMagneto optics applications
Magneto optics applications
 
Stairway Advertising Adverstep Technical Data Sheet
Stairway Advertising Adverstep Technical Data SheetStairway Advertising Adverstep Technical Data Sheet
Stairway Advertising Adverstep Technical Data Sheet
 
Elcometer 121 4-standard-top-paint-inspection-gauges is designed to measure t...
Elcometer 121 4-standard-top-paint-inspection-gauges is designed to measure t...Elcometer 121 4-standard-top-paint-inspection-gauges is designed to measure t...
Elcometer 121 4-standard-top-paint-inspection-gauges is designed to measure t...
 

More from link2013

More from link2013 (18)

Thermometers and probes
Thermometers and probesThermometers and probes
Thermometers and probes
 
Thermohygrometers
ThermohygrometersThermohygrometers
Thermohygrometers
 
Tachometer
TachometerTachometer
Tachometer
 
Stroboscope and gloss meter
Stroboscope and gloss meterStroboscope and gloss meter
Stroboscope and gloss meter
 
Sound level meters
Sound level metersSound level meters
Sound level meters
 
Pipe and cable locator
Pipe and cable locatorPipe and cable locator
Pipe and cable locator
 
Digital Ph meter
Digital Ph meterDigital Ph meter
Digital Ph meter
 
Particle counter arw 9880
Particle counter arw 9880Particle counter arw 9880
Particle counter arw 9880
 
Manometers and leak detector
Manometers and leak detectorManometers and leak detector
Manometers and leak detector
 
Laser distance meter
Laser distance meterLaser distance meter
Laser distance meter
 
Dynanometer
DynanometerDynanometer
Dynanometer
 
Insulation tester
Insulation testerInsulation tester
Insulation tester
 
Infrared thermometers
Infrared thermometersInfrared thermometers
Infrared thermometers
 
Geiger counter arw 9501
Geiger counter arw 9501Geiger counter arw 9501
Geiger counter arw 9501
 
Anemometer pitot tube arw 8920
Anemometer pitot tube arw 8920Anemometer pitot tube arw 8920
Anemometer pitot tube arw 8920
 
Clamp meters and Multimeters
Clamp meters and MultimetersClamp meters and Multimeters
Clamp meters and Multimeters
 
Thermo anemometers with vane probe
Thermo anemometers with vane probeThermo anemometers with vane probe
Thermo anemometers with vane probe
 
Electro smog meters
Electro smog metersElectro smog meters
Electro smog meters
 

Coating thickness gauge

  • 1. 14 COATING THICKNESS GAUGE ARW-156“FN” For order 220121954 This compact Coating thickness gauge with built-in probe dual-tecnology “FN” is suitable for the measurement of coa- tings (paint, zinc, plastic, rubber, ceramics, etc..) On both ferrous metals “F” (carbon steel, iron, cast iron, etc. .) and not- ferrous metals“N”(stainless steel,aluminum,copper,etc.).. This instrument is suitable for anyone who needs to measure a coating of paint or other coating easily and quickly with a reasonable cost. You just place the probe on the surface to be measured and you can immediately determine the thickness of the coating so identifying any repainting,inconsistency or unevenness of the surface tested. Coating Thickness Gauge with built-in probe Easy operation via“Menu”function (in English) Built-in probe“FN AUTO” Two selectable measuring modes:SINGLE (Single) CONTINUE (continued) Two recording modes:DIRECT (direct measurement) and GROUP (measurement divided into max.4 groups storable) Display statistical data:AVG (average),MAX (maximum),MIN (minimum),NO.,(N ° readings),S.DEV (standard deviation) Zero calibration simple Internal memory for 320 readings (80 for each group) Alarm signal (High) and (Low) USB interface and data management software Measuring range 0-1250um Resolution 0μm ÷-50μm 0,1μm 50μm ÷850μm 1μm than 10μm Accuracy +/- (2 μm + 3% of reading) o +/- (0.1mils + 3% of reading) Minimum thickness of the material (substrate) 0.5mm Memory 320 readings can be divided into max.4 batches Size 120x62x32mm Power supply Alkaline Batteries Weight 175gr. Supplied complete with USB cable,software for data management case and user manual TECHNICAL FEATURES Ideal for any type of coating (paint,plastic,zinc,chrome,rubber,ceramics,etc..),on magnetic metallic bases“FE”(versions 8826 F - FN 8826). FN 8826 version also allows you to measure coatings (paint, plastics, anodizing, chrome, rubber, ceramics, etc..) of non-magnetic metal bases“NFE”. Coating thickness gauge For coatings on ferrous ferrous metals (magnetic) For coatings on ferrous and non ferrous metals (magnetic and not-magnetic) ARW 8826 F ARW 8826 FN For order 220121334 For order 220121335 Thicknesses calibration standard in additional (values on request) Excellent quality/price Complete with separate probe with extension cable appropriate for each type of flat or radiused surface Easy and quick calibration with 4 thicknesses calibration stan- dard (50 - 100 - 200 -500 μm) Large LCD display with 4 digits Low battery warning Supplied with ABS case,probe (2 for FN 8826 version),Zero plate,4 thick- nesses calibration standard and user manual. Measuring range 0-1200 μm FE (FE-NFE version 8822) Resolution 0,1 μm up to 100 μm - 1 μm up to 2000 μm Accuracy ± 3% of reading or ± 2 μm Operating temperature 0 + 50°C Operating Humidity < 80% Power supply 4 batterie 1,5 V (AA-UM3) Size Instrument 161 x 69 x 32 mm Size probe Ø 15 mm - H 55 mm TECHNICAL FEATURES Optional accessories for ARW 8826 F - ARW 8826 FN www.measureinstruments.eu