www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường. Chuyên cung cấp vật tư cho dự án xử lý nước sạch, nước thải và môi trường. Envimart luôn đồng hành, tin cậy với đối tác nhà thầu, nhà tích hợp và người sử dụng.
1. Model F12/D Toxic Gas Transmitter -
Page 1 of 12
SS-F12_D, RN (1/22)
RS485 & JUNCTION BOX ENCLOSURE DIMENSIONS
ATI-0818a
Enclosure Dimensions
AC or DC POWERED ENCLOSURE DIMENSIONS
NOTES:
1) Enclosure Matl: Grey Polycarbonate w/S.S. Hardware
Weatherproof & Corrosion resistant
2) Ratings: Nema 4X ATI-0841a
NOTES:
1) Enclosure Matl: Grey Polycarbonate w/S.S. Hardware
Weatherproof & Corrosion resistant
2) Ratings: Nema 4X
3) Junction box DOES NOT contain an LCD front Panel
2. Model F12/D Toxic Gas Transmitter -
Page 2 of 12
SS-F12_D, RN (1/22)
ENCLOSURE MOUNTING OPTIONS
ATI-0821
Enclosure Mounting
PANEL MOUNT TRANSMITTER
ATI-0842
3. Model F12/D Toxic Gas Transmitter -
Page 3 of 12
SS-F12_D, RN (1/22)
TRANSMITTER CONNECTIONS
ATI-0844
TX / A(-)
G
-
To Aux On
Front Lid
JUMPER
INSTALLED
BY CUSTOMER
(-) 8
(L) 115/230 VAC
(N) - Neutral
(G) - Earth Ground
RX / B(+)
RL3
RL2
RL1
(+)
J4a
14
1
2
3
4
5
6
7
8
OPTIONAL
AC VERSION
(SHOWN)
1
TB6
Comm
(+) - 12-30 VDC
(-) - Neutral
(G) - Ground
TB3
CUSTOMER
CONNECTIONS
4-20 mA INPUT
PLC, DCS or
SCADA System
(RS232/485)
2
3
4
5
6
7
1
8
TB4
DC VERSION
+
POWERED 4-20mA OUTPUT WIRING
4. Model F12/D Toxic Gas Transmitter -
Page 4 of 12
SS-F12_D, RN (1/22)
Remote System
HEATED SENSOR WIRING DIAGRAMS
ATI-0903
Conductor Colors
T/B Pos Sensor
Wires
Generator
Wires
1 WHITE
2 YELLOW
3 BLUE BLUE
4 PURPLE WHITE
5 GRAY
6 GREEN
7 BLACK
8 BROWN BLACK
9 RED RED
10 ORANGE ORANGE
11 WHT / BLK
12 GREEN
IF USING CLOSE COUPLED HEATED
SENSOR (00-1699), WIRE
COLORS WILL BE PINK
IF USING 6 FT. HEATED SENSOR
(00-1878), WIRE COLORS WILL
BE RED.
TRANSMITTER AC OR VDC POWERED VERSION
REMOTE SYSTEM INTERCONNECT WIRING DIAGRAM
ATI-0840
5. Model F12/D Toxic Gas Transmitter -
Page 5 of 12
SS-F12_D, RN (1/22)
REMOTE SYSTEM (w/HEATED SENSOR) INTERCONNECT WIRING DIAGRAM (LOOP POWERED)
Remote System
TB4
TB3 14
1
1
2
3
4
5
6
7
8
J4a
TB6
G
N
L
RL3
RL2
RL1
2
3
4
5
6
7
1
8
Junction Box
WHT (AUX -)
BLK
(AUX +)
WHT (HTR -)
BLK (HTR +)
TB4
TB4
BLK
(G)
GRN
(Rx)
BLK
(Tx)
RED
(V+)
Shld
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
2
3
4
5
6
7
1
8
AC or 12/24 VDC Transmitter
EACH PAIR HAS A DRAIN
WIRE IN IT
DOES NOT MATTER WHICH
DRAIN IS CONNECTED DRAIN
ON (1) END ONLY
6 COND. (3 TWISTED PAIR) CABLE
(31-0068)
100 FT. MAX.
BLK
(G)
GRN
(Rx)
BLK
(Tx)
RED
(V+)
REMOTE SYSTEM (w/HEATED SENSOR) INTERCONNECT WIRING DIAGRAM (AC OR VDC POWERED)
6. Model F12/D Toxic Gas Transmitter -
Page 6 of 12
SS-F12_D, RN (1/22)
TRANSMITTER ACCESSORIES
ATI-0820
GAS TRANSMITTER
RELAY BOARD CONNECTIONS
ATI-0847
7. Model F12/D Toxic Gas Transmitter -
Page 7 of 12
SS-F12_D, RN (1/22)
INSERTION SENSOR DIMENSIONS PIPE ADAPTER DIMENSIONS
Sensor Dimensions
ATI-0670
ATI-0669
6ft. REMOTE SENSOR DIMENSIONS
(00-1702)
ATI-1032
8. Model F12/D Toxic Gas Transmitter -
Page 8 of 12
SS-F12_D, RN (1/22)
Dimensionals
INSERTION PROBE - OPERATING MODE
INSERTION PROBE - CALIBRATING MODE
ATI-0663
ATI-0664
9. Model F12/D Toxic Gas Transmitter -
Page 9 of 12
SS-F12_D, RN (1/22)
INTEGRAL INSERTION PROBE - DIMENSIONS
ATI-1131
10. Model F12/D Toxic Gas Transmitter -
Page 10 of 12
SS-F12_D, RN (1/22)
INTEGRAL INSERTION PROBE - OPERATING MODE
INSERTION PROBE - CALIBRATING MODE
ATI-1132
ATI-1133
11. Model F12/D Toxic Gas Transmitter -
Page 11 of 12
SS-F12_D, RN (1/22)
Wiring Diagrams
INSERTION PROBE - WIRING DIAGRAM
ATI-0876
Conductor Colors
TB3 Pos Sensor Wires
1 WHITE FROM SHLD
2 BROWN
3 RED & (2) DRAINS
4 BLACK
5 YELLOW
6 GREEN
7 BLUE
8 VIOLET
9 GRAY
10 WHITE
11 BLK/WHT
12 BLU/WHT
13 N/C
14 NC
12. Model F12/D Toxic Gas Transmitter -
Page 12 of 12
SS-F12_D, RN (1/22)
6 FT. SENSOR CABLE - WIRING DIAGRAM
ATI-0890
Wiring Diagrams
Conductor Colors
TB3 Pos Sensor Wires
1 WHITE
2 YELLOW
3 BLUE & (2) DRAINS
4 PURPLE
5 GRAY
6 N/C
7 BLACK
8 BROWN
9 RED
10 BLK w/ WHITE
11 N/C
12 GREEN
13 N/C
14 NC