The document provides installation instructions for an IntelliSense IS25100TC passive infrared motion sensor in 6 steps: 1) Select a mounting location, 2) Separate the sensor housings, 3) Mount the unit, 4) Wire the sensor, 5) Set the DIP switches, and 6) Configure the sensitivity and walk-test the sensor. Key details include guidelines for selecting a mounting location, how to connect wires and set switches, and how to test the sensor.
1. Select the mounting location. ❷ Separate the sensor housings and remove the printed cir- the Connect wires terminal
❶ cuit board (PCB).
❸ Mount the unit. ❹ Wire mmsensor. AWG). Observetothe properas shown using wire size 0.8
- 1.5 (22-16 polarity.
Wire
Knockouts
Corner
Mount Strain Relief Options
Knockouts
Wall Mount
Knockouts
#6
pan-head
screws
Test/Arm TAMPER ALARM POWER Test/Arm TAMPER ALARM POWER
0 VDC - Vsupply, 30 mA, 30 mA, 21 mA, 12 VDC,* 0 VDC - Vsupply, 30 mA, 30 mA, 21 mA, 12 VDC,*
1.8 mA max 24 VDC 24 VDC 25 mA max 1.8 mA max 24 VDC 24 VDC 25 mA max
Normally Closed Loop, No EOL Resistor Normally Open Loop, No EOL Resistor
Tamper Knockout
• Slide the wire through the wire knockouts in the
back housing, attach the wire with a wire tie,
Aim away from: and cut off the excess wire tie.
PCB Latch • Mount the back housing flat against a wall or in
a corner using #6 screws supplied. [Notes: If
Test/Arm TAMPER ALARM POWER Test/Arm TAMPER ALARM POWER
using the wall tamper, refer to the Tamper 0 VDC - Vsupply, 30 mA, 30 mA, 21 mA, 12 VDC,* 0 VDC - Vsupply, 30 mA, 30 mA, 21 mA, 12 VDC,*
1.8 mA max 24 VDC 24 VDC 25 mA max 1.8 mA max 24 VDC 24 VDC 25 mA max
Mounting Location Guidelines Switches section. If using a mounting bracket
• Use a small screwdriver to remove the cover screw (if see the Accessories section, and follow the Normally Closed Loop, w/ EOL Resistors Normally Open Loop, w/ EOL Resistors
• 2.3 m - 2.7 m (7.5' - 9') mounting height.
installed), then push in the housing latch at the bottom of the installation instructions supplied with the
• Avoid direct or reflected sunlight.
sensor, and gently pull apart the housings. bracket.]
• Aim sensor away from windows or heating/cooling devices. Note: EOL = Single End-of-Line supervised resistor.
• Push outward on the PCB latch and lift the PCB out of the • Replace the PCB.
• Sensor must have a clear line-of-sight to protected area.
housing. • Seal any openings with RTV compound. *For UL voltage, see Specifications Section.
❺ Set the DIP switches. ❻ Configure the sensitivity and walk-test the sensor.
Set the sensitivity appropriate for the application (see options below), replace the front cover, and apply power to the sensor. Begin walk-test
after the LED stops flashing (see the LED Operation section). Walk through the detection zones, observing the sensor’s LED whenever motion is
detected. The red LED shows actual alarm relay operation.
Install the look-down mask (black The absolute range of all PIR units is subject to variation because of different types of clothing, backgrounds, and ambient temperature. For this reason,
End of Line ring supplied) as shown, to reduce ensure that the most likely intruder routes are well within the PIR’s detection zones and that walk-testing is carried out along those routes.
(EOL) Screws the look-down sensitivity if desired.
Terminal
Block
SWITCH OFF ON
1 (PC) Pulse Count 2 Pulse Count 1
LED
2 (SENS) Low Sensitivity High Sensitivity
3 (LED) LED Disabled LED Enabled
4 (POL) Active Low Active High
DIP Polarity
Switch Test* Input (L) = Test*; (H) = Normal (H) = Test*; (L) = Normal
Arm Input (L) = Arm; (H) = Disarm (H) = Arm; (L) = Disarm
(Notes: Default switch settings are shown in grey.
PCB Latch See the Specifications section for more information on the
Test/Arm inputs. *Test = Remote LED Enable.)
IntelliSense® IS25100TC Passive Infrared Motion Sensor Installation Instructions
The PCB alignment
guide should
always point down,
as shown.
Note: Pulse count 2 setting is not Note: For High Security applications, disable the LED
recommended for long range devices. (S3=OFF), and set the sensitivity to High (S1 and S2=ON).