10. E.1002.31
INSTRUCTIONS
Please read the instructions before commencing installation and retain for future reference.
Fitting: Plastic
SPECIFICATIONS:
Power Source: 220-240V/AC
Detection Range: 360°
Power Frequency: 50Hz
Detection Distance: 6m max (<24℃)
Ambient Light: <3-2000LUX (adjustable)
Working Temperature: -20~+40°
Working Humidity: <93%RH
Power Consumption: approx 0.5W
Rated Load: Max.1200W
300W
Installation Height: 2.2-4m
Detection Moving Speed: 0.6-1.5m/s
Electrical products can cause death, injury, damage to property.
Installation of this product must be carried out by a qualified electrician, in accordance with
SANS 10142. On completion of installation, ensure that the Certificate of Compliance is
updated.
INSTALLATION INSTRUCTIONS:
Ensure mains supply switched off.
INSTALLATION ADVICE: Detector responds to changes in temperature, avoid the following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors, etc.
- Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, etc.
- Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
_____________________________________________________________________________________________________________________
- Rotate bottom cover anti-clockwise and remove. (Fig1)
- Insert power wire through the circular cut-out into the connection terminal (Fig1).
- Connect according to the connection-wire diagram (Fig2)
- Mount the bottom cover onto a selected position with supplied screws. (Fig1)
- Position the sensor onto the bottom cover and turn clockwise until it locks in place.
- After finishing installation, turn on the power and test it.
Setting up the Sensor
Set the LUX knob to the maximum (sun), TIME knob to the minimum (-).
Switch on the power; the sensor will be ON in standby mode. After the 30 second warm-up, the sensor is ready for function. Once there is movement, the sensor starts to
work. It will stop working within the time-delay 3-10 sec when there is no other detection found.
The sensor will resume once it detects a new movement.
Set LUX knob to the minimum (moon), which means the sensor will only work at night (<3LUX). If the ambient light around the testing site is more than 3LUX, the sensor
cannot work. For testing, you can use a piece of cloth for example, to cover the sensor to check if it works normally on night mode.
Spazio Lighting (Pty) LTD
JOHANNESBURG OFFICE: 52 Andries Street North | Wynberg/Sandton | South Africa | Tel: +27 11 555 5555 | Fax: +27 11 555 5544
CAPETOWN OFFICE: 105 Buitenkant Street | Gardens | 8001 | Tel: +27 21 461 0061 | Fax: +27 21 461 0063
info@spazio.co.za
Infrared Motion Sensor (SURFACE MOUNT)
Fig1
Fig2
11. E.1001.31
INSTRUCTIONS
Please read the instructions before commencing installation and retain for future reference.
Fitting: Plastic
SPECIFICATIONS:
Power Source: 220-240V/AC
Detection Range: 180°
Power Frequency: 50Hz
Detection Distance: 5m –12m max (<24C) adjustable
Ambient Light: <3-2000LUX (adjustable)
Working Temperature: -20~+40°
Working Humidity: <93%RH
Power Consumption: approx 0.5W
Rated Load: Max.1200W
300W
Installation Height: 1.8 – 2.5m
Detection Moving Speed: 0.6-1.5m/s
Electrical products can cause death, injury, damage to property.
Installation of this product must be carried out by a qualified electrician, in
accordance with SANS 10142. On completion of installation, ensure that the
Certificate of Compliance is updated.
INSTALLATION INSTRUCTIONS:
Ensure mains supply switched off.
INSTALLATION ADVICE: Detector responds to changes in temperature, avoid the
following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors, etc.
- Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, etc.
- Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants, etc.
_____________________________________________________________________________________________________________________
-Remove the faceplate using a screw-driver. (Fig 1) Pull the wire through the wire cut-out.
-Mount the device onto a selected position with the supplied screws (Fig 2).
-Connect the power wire according to the connection-wire diagram (Fig 3)
-Re-attach the front cover; turn on the power to test.
Setting up the Sensor
Set the LUX knob to the maximum (sun), TIME knob to the minimum (-).
Switch on the power; the sensor will be ON in standby mode. After the 30 second warm-up, the sensor is ready for function. Once there is movement, the sensor starts to
work. It will stop working within the time-delay 3-10 sec when there is no other detection found.
The sensor will resume once it detects a new movement.
Set LUX knob to the minimum (moon), which means the sensor will only work at night (<3LUX). If the ambient light around the testing site is more than 3LUX, the sensor
cannot work. For testing, you can use a piece of cloth for example, to cover the sensor to check if it works normally on night mode.
Spazio Lighting (Pty) LTD
JOHANNESBURG OFFICE: 52 Andries Street North | Wynberg/Sandton | South Africa | Tel: +27 11 555 5555 | Fax: +27 11 555 5544
CAPETOWN OFFICE: 105 Buitenkant Street | Gardens | 8001 | Tel: +27 21 461 0061 | Fax: +27 21 461 0063
info@spazio.co.za
Infrared Motion Sensor (WALL MOUNT)
Fig 1
Fig 2
Fig 3
12. E.1003.31
INSTRUCTIONS
Please read the instructions before commencing installation and retain for future reference.
Fitting: Plastic
SPECIFICATIONS:
Power Source: 220-240V/AC
Detection Range: 360°
Power Frequency: 50Hz
Detection Distance: 6m max (<24℃)
Ambient Light: <3-2000LUX (adjustable)
Working Temperature: -20~+40℃
Working Humidity: <93%RH
Power Consumption: approx 0.5W
Rated Load: Max.1200W
300W
Installation Height: 2.2 – 4m
Detection Moving Speed: 0.6-1.5m/s
Electrical products can cause death, injury, damage to property.
Installation of this product must be carried out by a qualified electrician, in
accordance with SANS 10142. On completion of installation, ensure that the
Certificate of Compliance is updated.
INSTALLATION INSTRUCTIONS:
Ensure mains supply switched off.
INSTALLATION ADVICE: Detector responds to changes in temperature, avoid the
following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors, etc.
- Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, etc.
- Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants, etc
_____________________________________________________________________________________________________________________
- Unclip the transparent vinyl cover which is at the bottom of the sensor and loosen the screws in the connection terminal (Fig 1)
- Connect the power to connection terminal of sensor according to the connection-wire diagram. (Fig 2)
- Install transparent vinyl cover back into the original location.
- Fold the springs upwards. (Fig 3)
- Fit into a cut-out or installation box, once inserted the clips will hold it securely in place. (Fig 4
- After finishing installation, turn on the power and test it.
Set the LUX knob to the maximum (sun), TIME knob to the minimum (-).
Setting up the Sensor
Switch on the power; the sensor will be ON in standby mode. After the 30 second warm-up, the sensor is ready for function. Once there is movement, the sensor starts to
work. It will stop working within the time-delay 3-10 sec when there is no other detection found.
The sensor will resume once it detects a new movement.
Set LUX knob to the minimum (moon), which means the sensor will only work at night (<3LUX). If the ambient light around the testing site is more than 3LUX, the sensor
cannot work. For testing, you can use a piece of cloth for example, to cover the sensor to check if it works normally on night mode.
Spazio Lighting (Pty) LTD
JOHANNESBURG OFFICE: 52 Andries Street North | Wynberg/Sandton | South Africa | Tel: +27 11 555 5555 | Fax: +27 11 555 5544
CAPETOWN OFFICE: 105 Buitenkant Street | Gardens | 8001 | Tel: +27 21 461 0061 | Fax: +27 21 461 0063
info@spazio.co.za
Recessed Infrared Motion Sensor
Fig 1
Fig 2
Fig 3
Fig 4