RIBO "ATEX" Series: the complete range of RIBO industrial vacuum cleaners complying with EEC/94/09 (ATEX) regulations.
Electric single-phase and three-phase, compressed-air-feeding industrial vacuum cleaners suitable to use in ATEX classified zone 1 - 21 and 2 - 22.
La marcatura ce degli aggregati riciclati bergamo 16.09
RIBO "ATEX" Series: industrial vacuum cleaners complying with ATEX regulations
1. R
ATEX SERIES
Aspiratori industriali conformi alla direttiva 94/09/CE
Industrial vacuum cleaners as per EEC/94/09 regulations
Dal 1968 qualità ed affidabilità garantite nel tempo
Since 1968 quality and reliability over the time
Aspirapolvere industriali
Apparecchiature tecniche per l’aspirazione industriale
Industrial vacuum cleaners
Vacuum technologies for industrial applications
C
M
Y
CM
MY
CY
CMY
K
scheda Atex 1.pdf 09/06/2006 17.25.18scheda Atex 1.pdf 09/06/2006 17.25.18
2. ASPIRATORI ELETTRICI MONOFASE E TRIFASE
RIBO ELECTRIC SINGLE-PHASE AND THREE-PHASEVACUUM CLEANERS
VS - ATEX
GLI ASPIRATORI RIBO DELLA SERIE VS SONO DISPONIBILI CON POTENZE DA 1,1 A 11 KW
RIBO VS-SERIES INDUSTRIAL VACUUM CLEANERS ARE AVAILABLE WITH POWER FROM 1,1 TO 11 KW
VS1,5
1,1 Kw
VS2
1,1 Kw
VS3
2,2 Kw
VS5
4 Kw
VS7
5,5 Kw
VS10
7,5 Kw
VS12
11 Kw
Gli aspiratori industriali trifase delle
serie VS sono disponibili per l'utilizzo
all'interno delle zone classificate in varie
configurazioni per l'aspirazione di:
- polveri e materiali solidi in
genere;
- trucioli anche abrasivi e taglienti;
- liquidi.
Possono essere impiegati sia come
unità aspiranti e filtranti mobili con
contenitori di varie dimensioni,sia come
unità fisse per impianti centralizzati e di
trasporto pneumatico (anche con
tramoggia di carico)
RIBO VS Series three-phase industiral
vacuum cleaners are fit for use in classified
zones in various configurations,for
vacuuming of:
-powders and dry solid materials
-sharp and abrasive swarfs
-liquids
RIBO vacuum cleaners can be used either as
mobile vacuuming and filtering units, with
containers featuring various dimensions,
either as central fixed vacuuming units and
conveying systems (also with loading
hopper)
modelli disponibili certificati/certified available models
2/22
per zone classificate
for classified zonesATEX 2
1/21
2/22
per zone classificate
for classified zonesATEX 1
La soluzione migliore per ogni
esigenza
di aspirazione industriale.
Potenza,versatilità di impiego,
continuità di servizio 24 ore su 24.
Alte prestazioni,ingombri ridotti
e livelli minimi di rumorosità
Tutto ciò con la tradizionale
QUALITA',AFFIDABILITA'
e ROBUSTEZZA
delle apparecchiature RIBO.
5 anni di garanzia
su tutti imodelli
Produttore da oltre
vent'anni di aspiratori
industriali in configurazione
anti-deflagrante ed anti-
fiamma RIBO ha adeguato le
proprie apparecchiature ai
requisiti imposti dalla normativa
ATEX,implementando tra l'altro:
- componenti elettrici con il più alto
grado di protezione richiesto;
- filtri antistatici in tessuto certificato con
trattamento ignifugo ed a ritardo di fiamma;
- Trattamento di plastificazione con polvere
epossidica conduttiva, utilizzo di compo-
nenti ed accessori in materiale conduttivo
per garantire la piena equipotenzialità e
messa a terra dell'apparecchiatura, con
valori di resistenza elettrica testati e
registrati su ciascun aspiratore.
C
M
Y
CM
MY
CY
CMY
K
scheda Atex 2.pdf 09/06/2006 17.29.02scheda Atex 2.pdf 09/06/2006 17.29.02
3. ASPIRATORI AD ALIMENTAZIONE PNEUMATICA
COMPRESSED-AIR VACUUM CLEANERS
COMPAIR - ATEX
GLI ASPIRATORI RIBO DELLA SERIE COMPAIR SONO DISPONIBILI CON DUE TIPOLOGIE DI TESTATA APSIRANTE
RIBO COMPAIR-SERIES INDUSTRIAL VACUUM CLEANERS ARE AVAILABLE WITH TWO TYPES OF VACUUMING GROUP
281
Modelli a 1 gruppo aspirante
1 suction unit models
551
Modelli a 2 gruppi aspiranti
2 suction units models
Gli aspiratori ad alimentazione
pneumatica della serie COMPAIR,
caratterizzati dalla COMPLETA ASSENZA
DI COMPONENTI ELETTRICI E DI ORGANI
IN MOVIMENTO, sono disponibili per
l'utilizzo all'interno delle zone classificate
in varie configurazioni, per L'aspirazione
di:
- polveri e materiali solidi in
genere;
- trucioli anche abrasivi e taglienti;
- liquidi.
Possono essere impiegati sia come unità
aspiranti e filtranti mobili con contenitori
di varie dimensioni, sia come unità fisse
per impianti centralizzati e di trasporto
pneumatico (anche con tramoggia di
carico)
RIBO compressed-air industrial vacuum
cleaners, featuring COMPLETE ABSENCE OF
ELECTRING COMPONENTS AND SELF-
MOVING PARTS, are fit for use in classified
zones,for vacuuming of:
-powders and dry solid materials
-sharp and abrasive swarfs
-liquids
RIBO vacuum cleaners can be used either as
mobile vacuuming and filtering units, with
containers featuring various dimensions,
either as central fixed vacuuming units and
conveying systems (also with loading
hopper)
modelli disponibili certificati/certified available models
2/22
per zone classificate
for classified zonesATEX 21/21
2/22
per zone classificate
for classified zonesATEX 1
The best solution for all the needs
of industrial cleaning and vacuuming
Power,use versatility,service
continuity 24h
High performance,compact size
and the lowest noise level
Everything with the traditional
QUALITY,RELIABILITY
and ROBUSTNESS
of RIBO vacuum cleaners
5 years warranty
on all the models
Over 20 year manufacturer
of explosion-proof and
flame-proof industrial
vacuum cleaners, RIBO has
updated its machines to the
requirements of ATEX regulations,
featuring among other things:
- electric components with the highest
protection level required;
- anti-static filters in certified material with
fire-proof and flame retadring threatment;
- Plasticized painting with epoxy conductive
powder and components/accessories in
conductive material, in order to grant full
equi-potentiality and earthing of the
machine, with tested resistence levels, on
every machine.
C
M
Y
CM
MY
CY
CMY
K
scheda Atex 3.pdf 09/06/2006 17.28.03scheda Atex 3.pdf 09/06/2006 17.28.03
4. sw.sodielac.wwwybcihparg
Le direttive 94/09/CE e 99/92/CE (direttive ATEX)
La direttiva 94/09/CE (obbligatoria dal 1 luglio 2003) regolamenta le caratteri-
stiche costruttive e di sicurezza che devono essere rispettate per l'installazione e
l'utilizzo di apparecchiature in ogni ambiente in cui può generarsi un'atmosfera
esplosiva.
Tutte le apparecchiature (parte elettrica e meccanica - sistemi, macchine singole,
componenti) destinate ad essere utilizzate in atmosfera potenzialmente esplosiva
generata da gas o polvere, devono essere conformi a questa direttiva
(certificazione o conformità ATEX).
La direttiva 99/92/CE ATEX (obbligatoria dal 1 luglio 2006) impone al datore di
lavoro di certificare le zone potenzialmente a rischio di esplosione,suddividendo
gli ambienti in cui può generarsi atmosfera esplosiva in ZONE CLASSIFICATE.
La direttiva 94/09/CE suddivide le apparecchiature utilizzabili nelle zone classifi-
cate in GRUPPI e CATEGORIE.
EEC/94/09 end EEC/99/92 regulations (ATEX regulations)
EEC/94/09 regulations (compulsory since July 1 2003). regulate the constructive
and safety characteristics to be respected in the installation and use of appliances
in every environment in which an explosive atmosphere could be generated.
All the equipment (electric and mechanic parts - systems, machines and compo-
nents) assigned to be used on potentially explosive atmosphere generated by gas
or dust, must be in keeping with ATEX regulations (ATEX certification
/conformity).
EEC/99/92 regulations (compulsory since July 1 2006) compel companies to
certify all the zones presenting potential risks of explosion, dividing all the
environment where explosive atmosphere could be generated in CLASSIFIED
ZONES.
EEC/94/09 regulations divide the equipment to be used in classified zones in
GROUPS and CATEGORIES.
GRUPPO/GROUP 2 - INDUSTRIE DI SUPERFICIE/SURFACE INDUSTRIES
Sostanza che genera l'atmosfera esplosiva
Substance generating explosive atmosphere
Gas
ZONA/ZONE 0 20 21 2 22
Gas
Continua
Continuous
Continua
Continuous
Intermittente
Intermittent
Occasionale
Occasional
Occasionale
Occasional
Polvere
Dust
Polvere
Dust
Gas
Gas
Polvere
Dust
Presenza di atmosfera esplosiva
Presence of explosive atmosphere
Categoria delle apparecchiature
Equipment category
1G 1D
1
Intermittente
Intermittent
Gas
Gas
2G 2D 3G 3D
R
RIBO s.r.l.
40050 VILLANOVA (BOLOGNA) ITALY
Via Tosarelli,173
Tel.+ 39 051 780280 Fax:+ 39 051 780230
www.ribo.net
e-mail:info@ribo.net
iadtiropirtatisonoidnicativi,licsoturtterosiavresiridroppateraidomfehciodnauq.onutroppo
errerutcafinameht;yrotacidniyleremsinevignoitamrofniehTcenmeedyamehsaemitynatasegnahcekamotthgirehtseves.yrasse
According to the classified zone where will be used, every single equipment
must belong to a specific category/group,following the scheme below.
A seconda della zona classificata in cui andrà ad essere utilizzata, ogni appa-
recchiatura deve appartenere ad una specifica categoria/gruppo, secondo lo
schema riportato di seguito.
C
M
Y
CM
MY
CY
CMY
K
scheda Atex 4.pdf 09/06/2006 17.26.04scheda Atex 4.pdf 09/06/2006 17.26.04