ARCH-256-PROJ-3-MBERG-2story.FDN.det.2
- 1. CALL FLOOR JOISTS HERE
@16" O.C. TYP.
#4 TOP AND BOTTOM TYP.
#4 VERT. @ 48" O.C. TYP.
6 MIL POLY (MIN) VAPOR
BARRIER ADHERE TO TOP OF
STEM WALL AND DRAPE
OVER FOOTING TYP.4" PERF. DRAINPIPE,
CONNECT TO APPROVED
DRAIN SYSTEM
1 1/2" (MINUS)
DRAIN ROCK TYP.
FILTER FABRIC
AS REQ.
iINSULATE RIM JOIST
W/ R30, R38 OR R38+
(MUST FILL CAVITY -
DEPTH OF JOIST) BATT.
INSULATION CONT. @
PARALLEL BAYS, 6-12
@ PERP. BAYS TYP.
5/8" OR 3/4" CDX
PLYWD. TYP.
R 21 BATT
INSULATION TYP.
1/2' GYP. BD. TYP.
1/2" DIA. X 12" ANCHOR BOLTS
W/ 7" EMBED @ 6'-0" O.C. TYP.
CONT. RIM JOIST TYP.
BUIDING WRAP ON 1/2"
OSB OR CDX PLYWD. ON
2X6'S @ 24" O.C. TYP.
3/8"MIN. W/ 1 1/2' MIN.
BATTENS @ EA. STUD TYP.
CALL SIDING HERE TYP.
3"
CLR.
CLR.
8"
6" @ (1) STRORY
1'-4"
8"
1'-6"8"
MIN.MIN.
111/2"
ENERGY TRUST 2-STORY FOUNDATION DETAIL OPT. 1
SCALE 1 1/2 = 1'-0" ARCH 256 W2 - M.BERG
6"@1-story
3" RIGID INSUL. @ STEM
WALL AND FOOTING.
SEAL JOINTS W/ SPRAY
FOAM INSUL. TYP.
EXTERIOR FINISH TYP.
FLASH TYP.
1" RIGID FOAM (OPT.)
SEAL ALL JOINTS
DENOTES CAULK OR
CONSTRUCTION ADHESIVE.
SEAL ALL JOINTS TO CREATE
AIR BARRIER. TYP.
APPLY SCREEN TO PERMIT
AIR FLOW AND EXCLUDE
INSECTS @RAINSCREEN TYP.
1'-0" @ 1-STORY
3"
UNDISTURBED SOIL TYP.