2. RDW2 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 1600, 2500, 4000, 6300A
Rated current: 200A~6300A
Rated operating voltage: AC 400V, AC 690V
Number of pole: 3P, 4P
Breaking capacity: 25kA~125kA
Installation mode: Fixed type, Drawer type
RDW1 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 630, 1000, 2000, 3200, 4000, 6300A
Rated current: 100A~6300A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 42kA~120kA
Installation mode: Fixed type, Drawer type
RDW17 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 1600, 1605, 2500, 2505, 3200, 3205A
Rated current: 630A~5000A
Rated operating voltage: AC 380V, AC 660V
Number of pole: 3P, 4P
Breaking capacity: 50kA~80kA
Installation mode: Fixed type, Drawer type
DW15 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 630, 1600, 2500, 4000, 6300A
Rated current: 200A~6300A
Rated operating voltage: AC 380V
Number of pole: 3P
Breaking capacity: 20kA~80kA
Installation mode: Fixed type, Drawer type (only for 630 type)
DW16 Series Intelligent Universal
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 630, 2000, 4000A
Rated current: 100A~4000A
Rated operating voltage: AC 400V
Number of pole: 3P
Breaking capacity: 20kA~80kA
RDM1 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 63, 100, 250, 400, 630, 800, 1250A
Rated current: 10A~1250A
Rated operating voltage: AC 400V, AC 690V
Number of pole: 2P (only for 100, 250 type), 3P, 4P
Breaking capacity: 25kA~100kA
RDM1E Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 63, 100, 250, 400, 630, 800, 1250A
Rated current: 10A~1250A
Rated operating voltage: AC 400V, AC 690V
Number of pole: 3P, 4P
Breaking capacity: 25kA~100kA
RDM11 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 100, 160, 250, 400, 630A
Rated current: 16A~630A
Rated operating voltage: AC 690V
Number of pole: 3P, 4P
Breaking capacity: 25kA~50kA
www.peopleelectric.com 016
3. RDM6 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 125, 160, 250, 400, 630, 800, 1250, 1600A
Rated current: 12.5A~1600A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 25kA~65kA
DZ20 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 100, 225, 400, 630, 1250, 2000A
Rated current: 16A~2000A
Rated operating voltage: AC 380V
Number of pole: 3P, 4P
Breaking capacity: 18kA~100kA
RDM108 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 20, 32, 63A
Rated current: 0.16A~63A
Rated operating voltage: AC 660V
Number of pole: 3P
Breaking capacity: 1.5kA~22kA
DZ15 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 40, 100A
Rated current: 6A~100A
Rated operating voltage: AC 220V, AC 380V
Number of pole: 1P, 2P, 3P, 4P
Breaking capacity: 3kA~5kA
RDM10 Series Moulded Case Circuit
Breaker (MCCB)
Confirms to: IEC60947-2
Frame size: 100, 160, 400, 630A
Rated current: 16A~630A
Rated operating voltage: AC 400V
Number of pole: 3P
Breaking capacity: 7.5kA~15kA
RDM1L Series Residual Operated
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 225, 400, 800A
Rated current: 10A~800A
Rated operating voltage: AC 400V
Number of pole: 2P (only for 100M, 225L, 225M type),
3P, 4P
Breaking capacity: 35kA~100kA
Residual operated current: 30/100/300/500/1000mA
RDL20 Series Residual Operated
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 160, 250, 400, 630A
Rated current: 50A~630A
Rated operating voltage: AC 380V
Number of pole: 3P +N
Breaking capacity: 12kA~30kA
Residual operated current: 100/200/300/500mA
RDM30LE Series Intelligent Leakage
Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 250, 400, 630A
Rated current: 63A~630A
Rated operating voltage: AC 380V
Number of pole: 3P +N
Breaking capacity: 6kA~36kA
Residual operated current: 100/300/500/1000mA
017 www.peopleelectric.com
Distribution Components
4. DZL25 Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 250A
Rated current: 40A~250A
Rated operating voltage: AC 380V
Number of pole: 4P
Breaking capacity: 6kA, 10kA
Residual operated current: 30/50/100/200/300/500mA
DZ15LE Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 40, 100A
Rated current: 6A~100A
Rated operating voltage: AC 220V, AC 380V
Number of pole: 2P, 3P, 4P
Breaking capacity: 3kA, 5kA
Residual operated current: 30/50/75/100mA
RDM10L Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 100, 250A
Rated current: 40A~250A
Rated operating voltage: AC 380V
Number of pole: 4P
Breaking capacity: 6kA, 10kA
Residual operated current: 75/100/150/200/300mA
RDL18 Series Leakage Circuit Breaker
Confirms to: IEC60947-2
Frame size: 20, 32A
Rated current: 10A~32A
Rated operating voltage: AC 220V
Number of pole: 2P
Breaking capacity: 500A
Residual operated current: 30mA
RDQH Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Frame size: 63, 100, 225, 400, 630, 800, 1250, 1600A
Rated current: 10A~1600A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 5kA~35kA
ATS grade: CB class
RDQ1 Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Frame size: 63A
Rated current: 6A~63A
Rated operating voltage: AC 220V, AC 400V
Number of pole: 2P, 3P, 4P
Breaking capacity: 5kA
ATS grade: CB class
RDWQ2 Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Frame size: 1000, 2000, 3200, 4000, 6300A
Rated current: 200A~6300A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 10kA~100kA
ATS grade: CB class
RDQ6 Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Rated current: 63A~3150A
Rated operating voltage: AC 400V
Number of pole: 2P, 3P, 4P
Breaking capacity: 5kA~80kA
ATS grade: PC class
www.peopleelectric.com 018
5. RDH5D Series Dual Power Supply
Automatic Transfer Switch
Confirms to: GB/T14048.11
Rated current: 32A~3200A
Rated operating voltage: AC 400V
Number of pole: 3P, 4P
Breaking capacity: 5kA~80kA
ATS grade: PC class
HD, HS Series Open Type Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 200, 400, 600, 1000, 1500, 2000, 3000A
Rated current: 100~3000A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~50kA
Number of pole: 1P, 2P, 3P, 4P
HS11FH Series Protective Open Type
Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400A
Rated current: 100~400A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~20kA
Number of pole: 3P, 4P
HD11F Series Open Type
Knife Switch
Mistake-proof
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400A, 600, 1000, 1500A
Rated current: 100~1500A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~40kA
Number of pole: 3P, 4P
HD11FH Series Protective Open Type
Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400A
Rated current: 100~400A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated short-time withstand current: 6kA~20kA
Number of pole: 3P, 4P
HR3 Series Fuse Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 100, 200, 400, 600, 1000A
Rated current: 100~1000A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Number of pole: 3P
RDHG1 Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Rated current: 32~63A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 3P
HR18 Series Fuse Knife Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated current: 160~630A
Rated operating voltage: AC 400V, AC 660V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 3P
019 www.peopleelectric.com
Distribution Components
6. RDHG2B Series Strip Type Fuse
Switch Disconnector
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated current: 160~630A
Rated operating voltage: AC 400V, AC 690V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 3P
HR5 Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated operating voltage: AC 380V, AC 660V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50~100kA
Number of pole: 3P
HR6 Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 250, 400, 630A
Rated operating voltage: AC 380V, AC 660V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50~100kA
Number of pole: 3P
HR17B Series Fuse Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 40, 60, 160, 250, 400, 630A
Rated operating current: 40~630A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Electrical life: 200~600 times
Number of pole: 2P, 3P, 4P
RDH5 Series Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 63, 100, 125, 160, 200, 400, 630, 1000,
1250, 1600, 2000, 2500, 3200A
Rated operating current: 63~3200A
Rated operating voltage: AC 400V
Rated impact withstand voltage: 8kV
Operation mode: operation inside of cabinet, operation
outside of cabinet
Number of pole: 3P, 4P
RDH5R Series Isolation Switch Fuse
Group
Confirms to: GB14048.3, IEC60947-3
Frame size: 160, 400, 630A
Rated operating current: 160~630A
Rated operating voltage: AC 380V
Rated impact withstand voltage: 8kV
Rated limit short-circuit current: 50kA
Number of pole: 2P, 3P, 4P
HH15 Series Isolation Switch Fuse
Group
Confirms to: GB14048.3, IEC60947-3
Rated operating current: (QSA) 63~800A
(QA) 125~1000A
(QP) 250~3150A
Rated operating voltage: AC 380V, AC 660V,
Rated limit short-circuit current: 50kA
Operation mode: operation outside of cabinet
Number of pole: 3P
JDW2 Series Low Voltage Outdoor
Isolation Switch
Confirms to: GB14048.3, IEC60947-3
Rated operating current: 200~800A
Rated operating voltage: AC 500V
www.peopleelectric.com 020
7. HH3 Series Load Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 60, 100, 150, 200, 300, 400, 600A
Rated current: 60~600A
Rated voltage: AC 380V
Rated limit short-circuit current: 50kA
Number of pole: 3P
HH4 Series Load Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 15, 30, 60, 100A
Rated current: 15~100A
Rated voltage: AC 380V
Rated limit short-circuit current: 50kA
Number of pole: 3P
HK2 Series Load Switch
Confirms to: GB14048.3, IEC60947-3
Frame size: 16, 32, 63, 75A
Rated current: 16~75A
Rated voltage: AC 220V, AC 380V
Rated limit short-circuit current: 50kA
Number of pole: 2P, 3P
RDT16 Series Powder Filled Cartridge
Knife Type Contact Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 10~1250A
Rated voltage: Up to AC 690V
Rated breaking capacity: 120kA
Scope of breaking and usage category: gG type and aM
type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RDF16 Series Powder Filled Cartridge
Knife Type Contact Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 16~630A
Rated voltage: Up to AC 690V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RL1 Series Screw Type Fuse
Confirms to: GB/T13539.3, IEC60269-3
Rated current: 2~200A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RT18, HG30 Series Powder Filled
Cartridge Cylindrical Cape Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 2~125A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
and aM type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RT19 Series Powder Filled Cartridge
Cylindrical Cape Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 2~100A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
and aM type
It is mainly used for electric circuit’s over-load and
short-circuit protection
021 www.peopleelectric.com
Distribution Components
8. RT14 Series Powder Filled Cartridge
Cylindrical Cape Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 2~63A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RT0 Series Powder Filled Cartridge
Knife Type Contact Fuse
Confirms to: GB/T13539.2, IEC60269-2
Rated current: 10~1000A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: gG type
It is mainly used for electric circuit’s over-load and
short-circuit protection
RS0, RS3 Series Fast Fuse
Confirms to: GB/T13539.4, IEC60269-4
Rated current: (RS 0) 10A~1250A
(RS 0) 10A~1000A
Rated voltage: AC 380V
Rated breaking capacity: 50kA
Scope of breaking and usage category: aR type
It is mainly used for the protection of semiconductor
crystal tube and its complete equipment
NGT Series Fast Fuse
Confirms to: GB/T13539.4, IEC60269-4
Rated current: 25~630A
Rated voltage: AC 380V, 660V, 800V, 1000V
Rated breaking capacity: 100kA
Scope of breaking and usage category: aR type
It is mainly used for the protection of semiconductor
crystal tube and its complete equipment
BSMJ (Y), BZMJ (Y) Series Auto-
Healing Low Voltage Shunt Capacitor
Confirms to: GB/T12847, IEC831-1
Rated operating voltage: AC 250V, AC 400V, AC 450V
AC 525V, AC 690V, AC 750V
Rated capacity: 1-50kvar
It can be used with CJ 19, combination switch
RD-ZM Series Intelligent Low Voltage
Capacitor
Confirms to: GB/T29312
Rated operating voltage: AC 380V/ 220V
Rated capacity: total compensation of 5~40kvar;
separated compensation of 5~20kvar
It can compensation in situ by one machine, and also
can networking to intelligently automatic operation by
multi-machines, and no need to add reactive compensation
controller to control.
JKW5C Series Low Voltage Reactive
Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP40
JKW6C Series Low Voltage Reactive
Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP40
www.peopleelectric.com 022
9. JKL6C, JKL6B Series Low Voltage
Reactive Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP 40
JKG2B, JKW5B Series Low Voltage
Reactive Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V/ 380V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 5A
Controlled circuit No.: 1~12 circuits
Protection grade: IP 40
JKWR Series Low Voltage Reactive
Compensation Controller
Confirms to: JB/T 9663
Rated operating voltage: AC 220V
Rated current: AC 0~5A
Capacity of contacts: AC 220V 7A
Controlled circuit No.: 1~13 circuits
Protection grade: IP 40
DB Series Distribution Box
JXF Series Outdoor Distribution
Box Enclosure
Rated voltage: 220/380V
Rated current: 125A
Installation: Surface mounted
Protection grade: Ip65
Height: 250; 300; 400; 500; 600; 800; 1000; 1200mm, etc.
Width: 200; 250; 300; 400; 500; 600; 1000mm, etc.
Depth: 150; 200; 250; 300mm, etc.
Modules: 4, 6, 8, 12, 18, 24, 34 ways
Installation: Surface mounting, Flush mounting
Material: Plastic, Metal
Protection grade: IP40
023 www.peopleelectric.com
Distribution Components