Our Burner Controllers can easily deal with flame monitoring, ignition, and fuel cutoff. They work well for the batch operations. These are made using the finest quality materials that have been bought from vendors who deal especially with few people only and we are one of them. The Burner Controllers have got a trial operation mode and seven segment displays using which you can carry out work and maintenance.
It’s quite safe to use
It’s easy to understand
It’s easy to see
It’s easy to use
The controllers are housed in an ABS plastic enclosure with overall size of 70 mm (L) x 110 mm (B) x 105 mm ( H). The enclosure consists of a base and Plug in Controller module, which facilitates easy replacement at sites.
MODELS FOR OIL FIRED BURNERS CONTROLLERS:
710 – PR – MA (equivalent to MA-81O Controllers) sensing by LDR.
712 – PR – 24 – PI4 (equivalent to LOA – 21 & LOA – 24 controllers)
FOR GAS FIRED BURNERS CONTROLLERS:
722 – FR – P5, where the flame sensing is done by using Flame Rod.
732 – UV – P5, where flame sensing is by UV Sensor.
2. ý www.linearsystemsindia.com
LINEAR SYSTEMS, a technocrat rm based in Mumbai (India)
is a well established and reputed manufacturer of Burner
Controllers for Boilers and Furnaces. Controllers are
manufactured deploying state-of-the-art technology.
Founded in 1986, the rm has relentlessly worked for
innovation for the Flame Monitoring in the process
industry. At Linear Systems, we believe in
LED Indication of Sequence Progress
Attractive and Compact Enclosures
Local and Remote Reset Facility
Two Years of Warranty
Work as a team with customers and suppliers
Demonstrate our respect, integrity and honesty in what
we do
Maintain a clean and healthy working environment
Growth coupled with customer’s satisfaction
Quality Products Timely Delivery
Cutomer SatisfactionAfter Sales Service
Features of Our Products
Our Vision
LS LINEAR SYSTEMS
Founded in 1986
3. BURNER / SEQUENCE CONTROLLERS
( For Big Size Burners )
Gas Fired Burners / Furnaces with UV Flame Sensing
307-GL-S Gas Controller, with Inbuilt UV Amplifer.
307-GID-P (inbuilt Amplier) & 307-GE-P (with External
Amplier)
307-GE-S Gas Controller, with External UV Amplier
with Piolet Flame, Damper, Blower and Ignition Terminals.
Without Piolet Flame Proving :
Oil Fired Burners/ Boilers:
107-S-60, 107-S-30 (Standard models
with pre purge time of 60 seconds and 30
seconds)
107-S-FO (Controller for Furnace Oil)
107-M ( Suitable for Nestler Boilers)
107-TU
LS-107 (Suitable for IAEC Make Boilers)
150-P-6 (Equivalent to MA-150 Controller)
100 / 200 / 300
Series Controllers
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
4. UV SENSOR AND AMPLIFIERS
UV Sensor 1
UV Sensor for
Oil/Gas Flames
UV Sensor 2
UV Amplier
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
5. LINEAR SYSTEM's Flame rod sensor senses the ame using
ame detection rectication technique. The Amplier provides
a voltage for the Flame Electrode. The ame electrode is
immersed in ame to sensed. The current thus generated by
the ow of electrons through the ame to the ground is
detected by the controller for presence of ame. The sensor
senses only the burning ame and completely insensitive to
visible light and refractory glows. It is best suited for sensing
ame in Gas red burners.
UV / FR / PR
(Flame Amplier)
FLAME ROD AMPLIFIERS
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
6. BURNER CONTROLLERS
(For small and medium sized industries)
Models for Oil Fired Burners Controllers:
For Gas Fired Burners Controllers:
710 - PR - MA (equivalent to MA-81O Controllers)
sensing by LDR.
712 - PR - 24 - PI4 (equivalent to LOA - 21 & LOA
- 24 Controllers)
722 - FR - P5, where the ame sensing is done by
using Flame Rod.
732 - UV - P5, where ame sensing is by UV Sensor.
The controllers are housed in
an ABS plastic enclosure with
overall size of 70mm(L)x110mm
(B)x105mm(H). The enclosure
consists of a base and Plug in
Controller module, which facilitates
easy replacement at sites.
700 Series Controllers
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
7. FLAME SENSORS FLAME SENSORS
FLAME SENSOR
FLAME SENSORS:
Flame Sensor uses a Light Dependent Resistor (LDR) for sensing
ame. The ame sensor essentially senses the "Light" emitted by
lame. It is usually suited only for oil burners in Boilers. It is not
suitable for Furnaces, where background fefractory brich glows.
These sensor senses all types of light, including Sun light and rays
emitted by electric bulb ltube light.
Models :-
Flame Sensor (FS - 1) with Front Viewing
Flame Sensor (FS - 2) with Side Viewing
Flame Sensor (FS - 3) Equivalent to Satronic Sensors
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
8. FLAME AMPLIFIER:
FLAME EYE (FE-01) is a ame detector, which is sensitive to visible
light. This used CDS (cadmium Sulphate) photo resistor as light
sensing device. This is suitable for sensing ame in oil red burners.
Amplier has two potential free relay contacts rated at 230V AC,
5 Amps.
UV / FR / PR
(Flame Amplier)
FLAME AMPLIFIER
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
9. LS LINEAR SYSTEMS
Founded in 1986
Technical Data-Ignition
System MKZ 100-(Part
No. 0 096 600 017)
Operating Voltage : 230V
(-15 %+10%) 50/60 Hz
Primary Current : 0.22 A
Output : 50 VA
IGNITION
TRANSFORMER
IGNITION TRANSFORMER
Connections
Primary
Secondary
Ignition voltage
Ignition Frequency
Ignition Spark Energy
Duty Cycle
Sparking distance
Fitting Position
Weight
Operating Temprature
2x at plug 2.8mm
2x4mm drops-in pins
2x7.5kV
25/30hz
approx. 500mJ
100%
1.5-3mm
0-60C
as required
300g
:
:
:
:
:
:
:
:
:
:
ý www.linearsystemsindia.com
10. LS LINEAR SYSTEMS
Founded in 1986
Detect small Ionisation current. Economical Flame
Sensor for small Gas Burners. Available in 6.25mm
Diameter and 3mm Diameter.
FLAME ROD FOR GAS FLAMES
Flame Rod
3 mm Dia
Flame Rod
6.25 mm Dia
ý www.linearsystemsindia.com
11. SOME OF OUR CLIENTS
LS LINEAR SYSTEMS
Founded in 1986
ý www.linearsystemsindia.com
12. Ofce Address
LS LINEAR SYSTEMS
Founded in 1986
To View E-Catalogue
Please Scan QR Code
307, Vikrant Industrial Estate,
Govandi Post Ofce Road,
Deonar, Mumbai - 400 088,
Maharashtra, India.
9820707710
(022) 2551 2534
(022) 2557 6002
info@linearsystemsindia.com
info@linearsystems.in
ý www.linearsystemsindia.com