- 1. UP
CO
CO
LAUNDRY
ROOM
003
ELEC.RM
001
SERV. ELEV.
058
PLUMBING
002
10"10"SD
10" SD
(13,150 SF)
(2) PW DN
W/ CHECK VALVE
& GATE VALVE
CONTROL
PANEL
3" DRAIN FROM
SPRINKLER
SYSTEM
3" DRAIN SPILL
ON GRADE
S-3
4"4" W
6"6" W
4"4"W
4"4"W
6"6"W
SE
3,4
SE
5,6
4"4" W
2"2" W
GI
1
4"4" W
SE-5,6
CONTROL
PANEL
PROVIDE 4" CO
3" FS-1
2"2" W
2"2" V
3" PW4"4" W
3" PW
2" CO
4" W DN
2"2" V
3" PW
WASHER
SE-7,8
CONTROL
PANEL
6"6" SD
2"2" SD 3"3" SD
2", 3" & 6" PUMPED
STORM DRAIN
FROM SP-1,2,3
SP-1,2,3
CONTROL
PANEL
SP
1,2,3
SE
7,8
4"4" GW
CO
3"3" GW
2"2" V
4"4"GW
3"3" GW
3" CO
3"3" GW
2"2" V
3"3" GW
2"2" GW
3"3" GW
3"3" GW
2"2" V
CO
3"3" GW
3"3" GW
2"2" V
2"2" V
3"3" GW
2"2" V
3"3" GW3"3" GW
2"2" V
3"3" GW
2"2" GW
4"4"GW4"4"GW4"4"GW
2"
2"GW
3"3" GW
2"2" V
2"2" V
3"3" GW
3"3" GW3"3" GW
4"4" GW
CO
3"3" GW
2"2" V
3"3" GW
3"3" GW
2"2" V
3"3" GW
3"3" GW2"2" W
6"6"W
3"3" W
3"3" W
3"3" W2"2" V
2"2" V
3"3" W
2"2" W
2"2" W
3"3" W
2"2" V
3"3" W
4"4" W 3"3" W 4"4" W
(FD)
(FS)
(FS)
(A-032)
(FD)
(FS)
(A-040)
(FS)
(FD)
(FS)
(A-135)
(FS)
(A-117)
2"2" V
(FS)
(FD)
(FD)
(FS)
(A-071)
3"3" GW2"2" V
2"2" W
(A-070)
(L)
(WC) 3"3" W
2"2" V
3"3" W
4"4" W
2"2" V
2"2"W
4"4" W4"4" W
4"4" W
2"2" W
4"4" W
6"6"W6"6"W6"6"W
(FS)
(FS)
(MS
)
2"2" W
6"6"W
2"2" W (A-091)
2"2" V
TD-1
3"3" V
2"2" V
(2) 2 1/2" PW DN
W/ CHECK VALVE
& GATE VALVE
2"2" W
4"4" W
4"4" W
2"2" W
6"6" W
(2)2 1/2" PW DN
3"3" V
3" PW
6"6" W
3"3" GV
3"3" GV
2"2" V4"4" GW
2" W UP TO POOL MAIN DRAIN
REFER TO POOL DRAWINGS
(TYP. FOR 4)
3" W FROM
POOL MAIN DRAIN
4"4" W
1
1" CD
1" CD
3
1" CD DN
1
1"1" CD
2
DRYERS
15" SD
WV
106-1
WV
103-1
WV
105-1
WV
107-1
WV
109-1
WV
102-1
WV
111-1
WV
104-1
WV
113-1
4"4" W
16 DFU'S
4"4" W
16 DFU'S
14 DFU'S
14 DFU'S
18 DFU'S
4"4"W
24 DFU'S
25 DFU'S
4"4"W
30 DFU'S
30 DFU'S
4"4"W
23 DFU'S
56 DFU'S
4"4" SD
6"6" SD
@ 1%
4"4" W
4"4" SD
6"6" SD
6"6" SD
6"6" SD
4"4" SD
6"6" SD
4"4" SD
8"8" SD
3"3" SD
3"3" SD
3"3" SD
3"3"SD
3"3" SD
6"6" SD
6"6" SD6"6" SD6"6" SD
3"3" SD
4"
4"SD
3"3"SD3"3"SD
3"3" SD 3"3" SD
3"3" W
3"3" SD
3"3" SD
3"3" SD 3"3" SD
3"3" SD
3"3" SD
3"3"SD
3"3" SD
3"3"SD
3"3" W
3"3" SD
3"3" SD
3"3"SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
6"6" SD
3"3" SD
3"3" SD
3"3" SD 3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3"SD4"4"SD
3"
3"SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
4"4"SD10"10"SD
6"6" SD
10"10"SD
2"2" V
2"2" V
3"3" GW
(FS)
3"3" V
3"3" V
3"3" SD
3"3" SD
3"3" SD
3"
3"SD
4"4" SD
10"10" SD
15" SD
3"3" SD
3"3" SD
3"3" SD
10"10" SD10"10" SD
3"3" SD
(B-022)
(FS)
(FS)
1
1"1" CD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
2
4
5
WASHER
5
(AD)
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3" SD
3"3"SD3"3"SD
3"
3"SD
3"3" SD
3"
3"SD
3"3"SD3"3"SD
SE
9,10
3" FD-1
2"2" V
SE-9,10
CONTROL
PANEL
2
2
2"2" V
2" V DN
FROM FS-1
3"3" V
3"3" SD
SE
11,12
P1.0B2
2
POOL
EQUIPMENT
016
4" PW @1%
3"3" V
3"3"V
3"3" V
2
3"3" SD
3"3" SD
3"3" SD
3"3" SD
(AD)
3"3" SD
(AD)
3"3" SD
(AD)
3"3" SD
3"3" SD
(PD)
4"4" SD 3"
3"SD
10"10" SD 10"10" SD
3"3" SD
3"3" SD
4"4" SD
3"3" SD
3"3" SD
3"3"SD
3"3" SD
3"3"SD
3"3" SD
3"3"SD
3"3" SD
3"3"SD
4"4" SD
3"3" SD3"3" SD
3"3" SD
3"3" SD
3"
3"SD
4"4" SD
4"4" SD
4"4" SD
4"4" W
4"4" W
4"4"W
2
70 DFU'S
4"4" W
4"4" W
4"4" W
76 DFU'S
2"2" W
1 1/2"1 1/2" V
(FS)
2
WV
101-1
4"4" W
2" PW
2"2" V
2"2" V
30 DFU'S
(AD) (AD) (AD)
3"3" SD3"3" SD
2"2" W
(SH)
2"2" V
2"2"W
2"2" W
4"4" W
6"6" W
6"6" W
6"6"W
EWS-1
4"4" W
4"4" W
4"4" W
4"4" W
4"4" W
30 DFU'S
30 DFU'S
SE-11,12
CONTROL
PANEL
SE
11,12
3" FD-1
EWS-1
3" FS-1
3" FS-1
POOL
EQUIPMENT
016
4" PW
@1%
(2)2 1/2" PW DN 3" W POOL DRAIN DN
WITH MIN. 6" AIRGAP
6
3" W FROM
POOL MAIN DRAIN
BELL RECEPTOR
2" W & V DN 2"2" V2"2" V
2"2" V
2" V DN
2" V ABOVE 9" AFF
2" V FROM SUMP PIT
2"2"V
2"2" V 3"3" V
(AD)
3"3" SD4"4" SD
10"10" SD
ArchitectureEngineeringPlanningInteriors
©,DLRGroupinc.,aCaliforniacorporation,ALLRIGHTSRESERVED
KEY PLAN
Revisions
PISMOBEACHHOTEL
147STIMSONAVENUE,PISMOBEACH,CA93449
NORTH
75-16718-00
02-09-16
4THPLANCHECKSUBMITTAL
09/30/2016
10/17/20166:47:48PM
C:Revit75-16718-00_MEP_2016_CENTRAL_klee.rvt
01/29/2016
PLUMBINGBASEMENTPLAN-WASTE&VENT-AREABP1.0B2
SCALE: 1/8" = 1'-0"P1.0B2
1 PLUMBING BASEMENT FLOOR PLAN - WASTE & VENT
KEY NOTES
FAN COIL UNIT. SEE MECHANICAL PLANS.
CONDENSATE DRAIN DOWN & CONNECT TO TAIL PIECE OF
THE LAVATORY/SINK P-TRAP. SEE DETAIL #42/P5.2.
CONDENSATE DRAIN DOWN & TERMINATE ABOVE MOP SINK
OR FLOOR SINK WITH AIR GAP. SEE DETAIL #43/P5.2.
UP TO TRENCH DRAIN
PUMPED RECYCLED WATER BETWEEN PIT PUMP & RECYCLED
WATER SYSTEM. SEE LAUNDRY DRAWINGS PL1.1 & PL1.2 FOR
REFERENCE.
SEE SWIMMING POOL DRAWING SP-10 FOR CONTINUATION.
1
2
3
4
5
SCALE: 1/4" = 1'-0"P1.0B2
2 PLUMBING ENLARGED PLAN - POOL EQUIPMENT
6
2
REGISTERE
D
PROFESSIONAL
ENGINEER
AI
NROFILACFOETAT
S
No. M 34223
ESANAT
COCEA
LACINAHCE
M
Exp. 12/31/16