1. Basic Concepts: Electricity
β’ The network of generating stations, substations and power line is
called the βpower systemβ.
β’ Voltage is the energy difference between the positive and negative
terminals of the battery.
ππππ‘πππ = πΆπ’πππππ‘ Γ π ππ ππ π‘ππππ
πππ€ππ = πΆπ’πππππ‘ Γ ππππ‘πππ
β’ Power Factor (pf) is a measure of the angular difference between
voltage and current.
2. Load behaviour
β’ The power required by electrical equipment is called Load.
β’ Load curve is a graph showing the value of total active power load for
a utility at different points of time in a day.
β’ Load factor (LF) is the ratio between average load and maximum load.
It is given in percentage.
β’ Load Duration curve for a year shows the number of hours in a year
that the load is equal, or more than a given MW value. It is used to
analyse the power system over a longer period of time, say one year.
3. Input-Output Curve
β’ The Input-Output curve is a graph of the heat input rate in kcal/h
against power output in kW.
π»πππ‘ π ππ‘π =
πΌπππ’π‘ πππ‘π ππ ππππ/β
ππ’π‘ππ’π‘ ππ ππ
β’ The units of heat rate are kcal/kWh
4. Major Concepts of the Power System
β’ The Installed Capacity of a generating unit is its maximum MW
capacity at the time of installation.
β’ For many reasons, the maximum capacity may reduce a little over a
period of time. This reduced capacity is called the Derated Capacity.
β’ The Minimum Capacity is the minimum MW at which the generating
unit can operate in a stable way.
β’ Energy generated by a generating unit is measured by metering
instruments at the station and can also be calculated if one knows the
average hourly MW generation.
5. Major Concepts of the Power System
β’ Plant Load Factor (PLF) for a generating unit is calculated as the ratio of energy actually
generated, to the energy it would have generated if it were operating at its maximum
capacity.
ππΏπΉ = 100 Γ
Energy generated in a year
Max energy generation possible in a year
3
β’ Availability of a generating unit is the average of the declared generating capacity values
over a period of time (typically a year). It is expressed as a percentage of the Installed
capacity minus auxiliary consumption.
π΄π£πππππππππ‘π¦ = 100 Γ
Hours for which the unit is available for generating power
Total Hours in the Year
6. Transmission Substation
β’ The transmission system consists of all the substations inter-
connected by transmission lines. It is like a mesh and is called the
transmission grid.
β’ A transmission substation is spread over a large area (a few 1000
square yards) with a lot of equipment. There will be:
β’ Transformers: used to convert one AC voltage to another
β’ Bus bars: a line at one voltage level to which many connections are made
β’ Circuit breakers: an elaborate switch used at high voltages and currents
β’ Isolators: A switch which cannot be operated when there is current flowing in
the circuit
β’ Protective relays: They are designed to sense when there are abnormal
voltages and currents
7. Protection System
β’ The equipment may damage when very high currents flow through it, due
to a fault.
β’ A Fault occurs when two transmission lines touch each other, or if one or
many lines touch the ground.
β’ The protection system starts acting when a fault happens.
β’ The relays detect the fault and give a signal to open the circuit breakers.
β’ The circuit breaker closes after some time and if the fault has disappeared,
the supply is restored.
β’ If the fault persists, the circuit breaker opens again. This cycle called βauto-
reclosingβ is repeated till the fault goes away. Otherwise, the circuit
breaker is kept open till an operator attends to it.
8. How the power system works
β’ The power system has three sub-systems. The sub-systems are:
β’ Distribution system, which is the first link to the consumer
β’ Transmission system, which carries bulk power from generating stations to
the distribution substations
β’ Generation system, which is the production centre
9. Features of Distribution System
β’ The distribution is coordinated from a Distribution Control Centre
(DCC).
β’ The DCC will have the layout of the substations and feeders in the
area and specifications of various equipments in the distribution
system.
β’ It will also handle load management and routine load-shedding
operations.
β’ Emergency load shedding instructions are conveyed from the head
office to the DCC, which in turn instructs the field staff to open some
feeders to reduce the load.
10. Features of Transmission System
β’ At the state level, the operation of power system is co-ordinated from the
Load Dispatch Centre (LDC), typically located in the state capital.
β’ It is connected to three or four Sub Load Dispatch Centres (Sub-LDCs), which
in turn are connected to major substations and generating stations.
β’ The state LDC is connected to the Regional LDC (RLDC). The RLDC monitors a
whole region.
11. Generation System
β’ Generating stations are the production centres, which function under
the co-ordination of the LDC. Private and state owned utilities get
instructions from the state LDC whereas the central generating
stations are instructed by the regional LDC (RLDC).
β’ Types of Generating Stations:
β’ Hydro Station
β’ Coal Based Station
β’ Gas-based station
β’ Nuclear station
β’ Wind, Solar, Bio-Gas, Co-Generation
12. Transmission and Distribution Loss
β’ The losses occur due to:
β’ Technical Loss- It occurs due to its physical characteristics (power lines,
transformers, substation equipment etc)
β’ Non-technical loss- It occurs due to wrong measurement (billing, by the
utility) of energy supplied to consumers
β’ T&D loss usually refers to the Active Energy Loss, occurring between
an energy source and a consumer, over a period of time.