The paper describes the use of Newton Raphson method to control the Input signal level to an Amplifier to achieve a desired Output level. The normal method is to start from a pre-determined input ,and then slowly increasing the input levels in discrete steps until the desired Output is achieved. This Newton Ralphson method achieved the desired output in less than 3-4 iterations when used in Production Quality Control setup, reducing Test Cycle Time.