SlideShare a Scribd company logo
1 of 8
Download to read offline
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
1G 1290nm 80km CDWM SFP Transceiver
Specification Revision Record
Date Version Page Revision Description Prepare Approve
20210706 1.0 Zhang S
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 1G 1290nm 80km CDWM SFP Transceiver
Model SFP-1G-CWDM-1290-80
File No. SFP-1G-CWDM-1290-80-T02#151042
Version 1.0
Issuing Date 2021-7-6
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
SFP-1G-CWDM-1290-80-T02 SFP transceivers are high performance, cost effective modules supporting
data-rate of 1.25Gb/s and 80km transmission distance with SMF. The transceiver consists of three
sections: an uncooled CWDM DFB laser transmitter, a PIN photodiode integrated with a trans-impedance
preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The
transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further
information, please refer to SFP MSA.
Product Feature
Supports bit rates up to1.25Gbps
Duplex LC connector
Hot pluggable SFP footprint
CWDM 1290nm laser transmitter and PIN photo-detector
Applicable for 80Km SMF connection
Low power consumption, < 0.8W
Digital Diagnostic Monitor Interface
Compliant with SFP MSA and SFF-8472
Very low EMI and excellent ESD protection
Operating case temperature: 0 to 70 °C (commercial)
Application
Gigabit Ethernet
WDM systems
Switch to Switch interface
Switched backplane applications
Router/Server interface
Other optical transmission systems
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Functional Diagram
Absolute Maximum Ratings
Parameter Symbol Min Max Unit Note
Supply Voltage Vcc -0.5 4.0 V
Storage Temperature Ts -40 85 °C
Relative Humidity RH 0 85 %
Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver.
General Operating Characteristic
Parameter Symbol Min Typ Max Unit Note
Supply Voltage Vcc 3.13 3.3 3.47 V
Supply Current Icc 220 mA
Data Rate DR 1.25 Gb/s
Operating Case Temperature Tc 0 70 °C Commercial
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V)
Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V)
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Operating Wavelength λ λ-7.5nm λ λ+7.5nm nm 1
Ave. output power
(Enabled)
PAVE 0 5 dBm 2
Extinction Ratio ER 9 dB 2
RMS spectral width Δλ 1 nm
Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 3
Parameter Symbol Min. Typ Max. Unit Note
Transmitter
Differential data input swing VIN,PP 120 820 mVpp 1
Tx Disable Input-High VIH 2.0 Vcc+0.3 V
Tx Disable Input-Low VIL 0 0.8 V
Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2
Tx Fault Output-Low VOL 0 0.5 V 2
Input differential impedance Rin 100 Ω
Receiver
Differential data output swing Vout,pp 300 650 800 mVpp 3
Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2
Rx LOS Output-Low VROL 0 0.8 V 2
Notes:
1. TD+/- are internally AC coupled with 100Ω differential termination inside the module.
2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ
resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V.
3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user
SERDES.
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Dispersion penalty TDP 3.9 dB
Output Optical Eye Compliant with IEEE802.3 z (class 1 laser safety)
Receiver
Operating Wavelength λ 1270 1610 nm
Receiver Sensitivity PSEN1 -24 dBm 4
Overload PAVE -3 dBm 4
LOS Assert Pa -35 dBm
LOS De-assert Pd -25 dBm
LOS Hysteresis Pd-Pa 0.5 dB
Notes
1. λ means 1270nm~1610nm, Total 18 wavelengths, 20nm spacing.
2. Measured at 1.25 Gb/s with PRBS 2 223 – 1
NRZ test pattern.
3. Unfiltered, measured with a PRBS223 – 1
test pattern @1.25Gbps
4. Measured at 1.25Gb/s with PRBS 223 – 1 NRZ test pattern for BER < 1x10-12
Pin Definition And Functions
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
Pin Symbol Name/Description Notes
1 VeeT Tx ground
2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1
3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2
4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3
5 MOD-DEF1 2 wire serial interface clock input (SCL) 3
6 MOD-DEF0 Model present indication 3
7 Rate select No connection
8 LOS Rx loss of signal, Open Collector Output, active “H” 4
9 VeeR Rx ground
10 VeeR Rx ground
11 VeeR Rx ground
12 RD- Inverse received data out 5
13 RD+ Received data out 5
14 VeeR Rx ground
15 VccR Rx power supply
16 VccT Tx power supply
17 VeeT Tx ground
18 TD+ Transmit data in 6
19 TD- Inverse transmit data in 6
20 VeeT Tx ground
Notes:
1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And
should be pulled up with a 4.7 – 10KΩ resistor on the host board.
2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within
the module with a 4.7 – 10KΩ resistor. Its states are:
Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined
High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 7 -
3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10K
Ω resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V.
Mod-Def 0 has been grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4. When high, this output indicates loss of signal (LOS). Low indicates normal operation.
5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines
which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done
inside the module and is thus not required on the host board.
6. D+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on the host board.
Digital Diagnostic Specifications
The SFP-1G-CWDM-1290-80-T02 transceivers can be used in host systems that require
either internally or externally calibrated digital diagnostics.
Parameter Symbol Units Min. Max. Accuracy Note
Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1
Transceiver supply voltage DVoltage V 2.8 4.0 ±3%
Transmitter bias current DBias mA 2 80 ±10% 2
Transmitter output power DTx-Power dBm -3 +8 ±3dB
Receiver average input power DRx-Power dBm -27 0 ±3dB
Notes:
1.When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75
2.The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser
3. Internal/ External Calibration compatible.
SFP-1G-CWDM-1290-80-T02#151042
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 8 -
Typical Interface Circuit
Package Dimensions
Wavelength Latch Color
1290nm Gray
Ordering Information
Part Number Description
SFP-1G-CWDM-1290-80
SFP, 1.25G, CWDM, 1290nm, 80Km, 0~70℃,
with Digital Diagnostic Monitor

More Related Content

Similar to sfp-1g-cwdm-1290nm-80km-transceiver-module-151042.pdf

Similar to sfp-1g-cwdm-1290nm-80km-transceiver-module-151042.pdf (20)

sfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdf
sfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdfsfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdf
sfp-1g-cwdm-1430nm-80km-optical-transceiver-151049.pdf
 
sfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdf
sfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdfsfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdf
sfp-1g-cwdm-1610nm-80km-fiber-optical-module-151058.pdf
 
sfp-1g-cwdm-1470nm-80km-fiber-optical-transceiver-151051.pdf
sfp-1g-cwdm-1470nm-80km-fiber-optical-transceiver-151051.pdfsfp-1g-cwdm-1470nm-80km-fiber-optical-transceiver-151051.pdf
sfp-1g-cwdm-1470nm-80km-fiber-optical-transceiver-151051.pdf
 
sfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdf
sfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdfsfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdf
sfp-1g-cwdm-1530nm-80km-fiber-optical-transceiver-151054.pdf
 
sfp-1g-cwdm-1450nm-80km-optical-transceiver-151050.pdf
sfp-1g-cwdm-1450nm-80km-optical-transceiver-151050.pdfsfp-1g-cwdm-1450nm-80km-optical-transceiver-151050.pdf
sfp-1g-cwdm-1450nm-80km-optical-transceiver-151050.pdf
 
SFP-1G-CWDM-1450-80-T02#151050.pdf
SFP-1G-CWDM-1450-80-T02#151050.pdfSFP-1G-CWDM-1450-80-T02#151050.pdf
SFP-1G-CWDM-1450-80-T02#151050.pdf
 
sfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdf
sfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdfsfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdf
sfp-1g-cwdm-1550nm-80km-transceiver-module-151055.pdf
 
sfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdf
sfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdfsfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdf
sfp-1g-cwdm-1350nm-80km-fiber-optical-module-151045.pdf
 
sfp-1g-cwdm-1270nm-80km-fiber-optical-module-151041.pdf
sfp-1g-cwdm-1270nm-80km-fiber-optical-module-151041.pdfsfp-1g-cwdm-1270nm-80km-fiber-optical-module-151041.pdf
sfp-1g-cwdm-1270nm-80km-fiber-optical-module-151041.pdf
 
sfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdf
sfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdfsfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdf
sfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdf
 
sfp-1g-cwdm-1270nm-40km-fiber-optical-module-151023.pdf
sfp-1g-cwdm-1270nm-40km-fiber-optical-module-151023.pdfsfp-1g-cwdm-1270nm-40km-fiber-optical-module-151023.pdf
sfp-1g-cwdm-1270nm-40km-fiber-optical-module-151023.pdf
 
sfp-1g-cwdm-1290nm-40km-fiber-optical-module-151024.pdf
sfp-1g-cwdm-1290nm-40km-fiber-optical-module-151024.pdfsfp-1g-cwdm-1290nm-40km-fiber-optical-module-151024.pdf
sfp-1g-cwdm-1290nm-40km-fiber-optical-module-151024.pdf
 
sfp-1g-cwdm-1370nm-40km-fiber-tranceiver-151028.pdf
sfp-1g-cwdm-1370nm-40km-fiber-tranceiver-151028.pdfsfp-1g-cwdm-1370nm-40km-fiber-tranceiver-151028.pdf
sfp-1g-cwdm-1370nm-40km-fiber-tranceiver-151028.pdf
 
sfp-1g-cwdm-1330nm-40km-fiber-optical-module-151026.pdf
sfp-1g-cwdm-1330nm-40km-fiber-optical-module-151026.pdfsfp-1g-cwdm-1330nm-40km-fiber-optical-module-151026.pdf
sfp-1g-cwdm-1330nm-40km-fiber-optical-module-151026.pdf
 
sfp-1g-cwdm-1310nm-40km-fiber-optical-module-151025.pdf
sfp-1g-cwdm-1310nm-40km-fiber-optical-module-151025.pdfsfp-1g-cwdm-1310nm-40km-fiber-optical-module-151025.pdf
sfp-1g-cwdm-1310nm-40km-fiber-optical-module-151025.pdf
 
sfp-1g-cwdm-1450nm-40km-fiber-optical-module-151032.pdf
sfp-1g-cwdm-1450nm-40km-fiber-optical-module-151032.pdfsfp-1g-cwdm-1450nm-40km-fiber-optical-module-151032.pdf
sfp-1g-cwdm-1450nm-40km-fiber-optical-module-151032.pdf
 
sfp-1g-cwdm-1590nm-40km-fiber-optical-module-151039.pdf
sfp-1g-cwdm-1590nm-40km-fiber-optical-module-151039.pdfsfp-1g-cwdm-1590nm-40km-fiber-optical-module-151039.pdf
sfp-1g-cwdm-1590nm-40km-fiber-optical-module-151039.pdf
 
sfp-1g-cwdm-1390nm-40km-optical-transceiver-module-151029.pdf
sfp-1g-cwdm-1390nm-40km-optical-transceiver-module-151029.pdfsfp-1g-cwdm-1390nm-40km-optical-transceiver-module-151029.pdf
sfp-1g-cwdm-1390nm-40km-optical-transceiver-module-151029.pdf
 
sfp-1g-cwdm-1470nm-40km-fiber-optical-module-151033.pdf
sfp-1g-cwdm-1470nm-40km-fiber-optical-module-151033.pdfsfp-1g-cwdm-1470nm-40km-fiber-optical-module-151033.pdf
sfp-1g-cwdm-1470nm-40km-fiber-optical-module-151033.pdf
 
SFP-1G-CWDM-1470-40-T02#151033.pdf
SFP-1G-CWDM-1470-40-T02#151033.pdfSFP-1G-CWDM-1470-40-T02#151033.pdf
SFP-1G-CWDM-1470-40-T02#151033.pdf
 

More from GLsun Mall

osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
GLsun Mall
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
GLsun Mall
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
GLsun Mall
 

More from GLsun Mall (20)

to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfto56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
 
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfto56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
 
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfto56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
 
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfosw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
 
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfosw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
 
fsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docfsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.doc
 
fsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docfsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.doc
 
fsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docfsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.doc
 
fsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docfsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.doc
 
fsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docfsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.doc
 
multi-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfmulti-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdf
 
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
 
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
 
1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf
 
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
 
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
 
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
 

Recently uploaded

CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
giselly40
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
Earley Information Science
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
vu2urc
 

Recently uploaded (20)

Real Time Object Detection Using Open CV
Real Time Object Detection Using Open CVReal Time Object Detection Using Open CV
Real Time Object Detection Using Open CV
 
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
Bajaj Allianz Life Insurance Company - Insurer Innovation Award 2024
 
A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)A Domino Admins Adventures (Engage 2024)
A Domino Admins Adventures (Engage 2024)
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptxEIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
EIS-Webinar-Prompt-Knowledge-Eng-2024-04-08.pptx
 
The Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptxThe Codex of Business Writing Software for Real-World Solutions 2.pptx
The Codex of Business Writing Software for Real-World Solutions 2.pptx
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...Workshop - Best of Both Worlds_ Combine  KG and Vector search for  enhanced R...
Workshop - Best of Both Worlds_ Combine KG and Vector search for enhanced R...
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?What Are The Drone Anti-jamming Systems Technology?
What Are The Drone Anti-jamming Systems Technology?
 
Slack Application Development 101 Slides
Slack Application Development 101 SlidesSlack Application Development 101 Slides
Slack Application Development 101 Slides
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 
Advantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your BusinessAdvantages of Hiring UIUX Design Service Providers for Your Business
Advantages of Hiring UIUX Design Service Providers for Your Business
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 

sfp-1g-cwdm-1290nm-80km-transceiver-module-151042.pdf

  • 1. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 1 - 1G 1290nm 80km CDWM SFP Transceiver Specification Revision Record Date Version Page Revision Description Prepare Approve 20210706 1.0 Zhang S All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission, any unit or individual can’t reproduce, copy or use it for any commercial purpose. Product 1G 1290nm 80km CDWM SFP Transceiver Model SFP-1G-CWDM-1290-80 File No. SFP-1G-CWDM-1290-80-T02#151042 Version 1.0 Issuing Date 2021-7-6
  • 2. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 2 - Product Description SFP-1G-CWDM-1290-80-T02 SFP transceivers are high performance, cost effective modules supporting data-rate of 1.25Gb/s and 80km transmission distance with SMF. The transceiver consists of three sections: an uncooled CWDM DFB laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information, please refer to SFP MSA. Product Feature Supports bit rates up to1.25Gbps Duplex LC connector Hot pluggable SFP footprint CWDM 1290nm laser transmitter and PIN photo-detector Applicable for 80Km SMF connection Low power consumption, < 0.8W Digital Diagnostic Monitor Interface Compliant with SFP MSA and SFF-8472 Very low EMI and excellent ESD protection Operating case temperature: 0 to 70 °C (commercial) Application Gigabit Ethernet WDM systems Switch to Switch interface Switched backplane applications Router/Server interface Other optical transmission systems
  • 3. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 3 - Functional Diagram Absolute Maximum Ratings Parameter Symbol Min Max Unit Note Supply Voltage Vcc -0.5 4.0 V Storage Temperature Ts -40 85 °C Relative Humidity RH 0 85 % Note: Stress in excess of the maximum absolute ratings can cause permanent damage to the transceiver. General Operating Characteristic Parameter Symbol Min Typ Max Unit Note Supply Voltage Vcc 3.13 3.3 3.47 V Supply Current Icc 220 mA Data Rate DR 1.25 Gb/s Operating Case Temperature Tc 0 70 °C Commercial
  • 4. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 4 - Electrical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V) Optical Characteristics (TOP(C) = 0 to 70 ℃, TOP(I) =-40 to 85 ℃, VCC = 3.13 to 3.47 V) Parameter Symbol Min. Typ Max. Unit Note Transmitter Operating Wavelength λ λ-7.5nm λ λ+7.5nm nm 1 Ave. output power (Enabled) PAVE 0 5 dBm 2 Extinction Ratio ER 9 dB 2 RMS spectral width Δλ 1 nm Rise/Fall time (20%~80%) Tr/Tf 0.26 ns 3 Parameter Symbol Min. Typ Max. Unit Note Transmitter Differential data input swing VIN,PP 120 820 mVpp 1 Tx Disable Input-High VIH 2.0 Vcc+0.3 V Tx Disable Input-Low VIL 0 0.8 V Tx Fault Output-High VOH 2.0 Vcc+0.3 V 2 Tx Fault Output-Low VOL 0 0.5 V 2 Input differential impedance Rin 100 Ω Receiver Differential data output swing Vout,pp 300 650 800 mVpp 3 Rx LOS Output-High VROH 2.0 Vcc+0.3 V 2 Rx LOS Output-Low VROL 0 0.8 V 2 Notes: 1. TD+/- are internally AC coupled with 100Ω differential termination inside the module. 2. Tx Fault and Rx LOS are open collector outputs, which should be pulled up with 4.7k to 10kΩ resistors on the host board. Pull up voltage between 2.0V and Vcc+0.3V. 3. RD+/- outputs are internally AC coupled, and should be terminated with 100Ω (differential) at the user SERDES.
  • 5. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 5 - Dispersion penalty TDP 3.9 dB Output Optical Eye Compliant with IEEE802.3 z (class 1 laser safety) Receiver Operating Wavelength λ 1270 1610 nm Receiver Sensitivity PSEN1 -24 dBm 4 Overload PAVE -3 dBm 4 LOS Assert Pa -35 dBm LOS De-assert Pd -25 dBm LOS Hysteresis Pd-Pa 0.5 dB Notes 1. λ means 1270nm~1610nm, Total 18 wavelengths, 20nm spacing. 2. Measured at 1.25 Gb/s with PRBS 2 223 – 1 NRZ test pattern. 3. Unfiltered, measured with a PRBS223 – 1 test pattern @1.25Gbps 4. Measured at 1.25Gb/s with PRBS 223 – 1 NRZ test pattern for BER < 1x10-12 Pin Definition And Functions
  • 6. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 6 - Pin Symbol Name/Description Notes 1 VeeT Tx ground 2 Tx Fault Tx fault indication, Open Collector Output, active “H” 1 3 Tx Disable LVTTL Input, internal pull-up, Tx disabled on “H” 2 4 MOD-DEF2 2 wire serial interface data input/output (SDA) 3 5 MOD-DEF1 2 wire serial interface clock input (SCL) 3 6 MOD-DEF0 Model present indication 3 7 Rate select No connection 8 LOS Rx loss of signal, Open Collector Output, active “H” 4 9 VeeR Rx ground 10 VeeR Rx ground 11 VeeR Rx ground 12 RD- Inverse received data out 5 13 RD+ Received data out 5 14 VeeR Rx ground 15 VccR Rx power supply 16 VccT Tx power supply 17 VeeT Tx ground 18 TD+ Transmit data in 6 19 TD- Inverse transmit data in 6 20 VeeT Tx ground Notes: 1. When high, this output indicates a laser fault of some kind. Low indicates normal operation. And should be pulled up with a 4.7 – 10KΩ resistor on the host board. 2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10KΩ resistor. Its states are: Low (0 – 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0V~Vcc+0.3V): Transmitter Disabled Open: Transmitter Disabled
  • 7. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 7 - 3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10K Ω resistor on the host board. The pull-up voltage shall be between 2.0V~Vcc+0.3V. Mod-Def 0 has been grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4. When high, this output indicates loss of signal (LOS). Low indicates normal operation. 5. RD+/-: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. 6. D+/-: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. Digital Diagnostic Specifications The SFP-1G-CWDM-1290-80-T02 transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics. Parameter Symbol Units Min. Max. Accuracy Note Transceiver temperature DTemp-E ºC -45 +90 ±5ºC 1 Transceiver supply voltage DVoltage V 2.8 4.0 ±3% Transmitter bias current DBias mA 2 80 ±10% 2 Transmitter output power DTx-Power dBm -3 +8 ±3dB Receiver average input power DRx-Power dBm -27 0 ±3dB Notes: 1.When Operating temp.=0~70 ºC,the range will be min=-5,Max=+75 2.The accuracy of the Tx bias current is 10% of the actual current from the laser driver to the laser 3. Internal/ External Calibration compatible.
  • 8. SFP-1G-CWDM-1290-80-T02#151042 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 8 - Typical Interface Circuit Package Dimensions Wavelength Latch Color 1290nm Gray Ordering Information Part Number Description SFP-1G-CWDM-1290-80 SFP, 1.25G, CWDM, 1290nm, 80Km, 0~70℃, with Digital Diagnostic Monitor