SlideShare a Scribd company logo
1 of 3
Download to read offline
Fluke Industrial
   Thermal Imagers
       Models: Ti32, Ti25 and Ti10
                                                                                                  Technical Data


                                                              High performance thermal
                                                              imagers have never been this
                                                              affordable. This rugged. Or,
                                                              this easy to use … until now.
                                                              We, at Fluke, are never satisfied leaving the best tools in the hands
                                                              of the elite, which is why we recently added a new member to our
                                                              thermal imaging family. The new Fluke Ti32 combines a powerful
                                                              320x240 sensor into the award winning, rugged design of the Ti25
                                                              and Ti10, delivering the first industrial grade, high performance
                                                              thermal imager. The result is strikingly crisp, detailed images that,
                                                              blended with our patented IR-Fusion®, are sure to make a lasting
                                                              impression. Don’t take our word for it—see it yourself!
Ti32                                                             Fluke thermal imagers are designed, tested, and manufactured in the
                                                              USA, and feature a two year warranty. Work in a harsh environment?
                                                              Don’t worry. These meet the stringent quality standards that Fluke prod-
                                                              ucts are known for worldwide. Able to withstand a 2 meter (6.5 foot)
                        Ti25                                  drop, they also meet the requirements for an IP54 rating against dust
                                                              and moisture.
         Industrial, mechanical,                                 For added versatility and special applications, the Ti32 includes two
         electromechanical and general                        field-swappable, rechargeable batteries. Use the optional telephoto and
         building maintenance.
                                                              wide-angle lenses to bring distant and wide views into sharp focus.
         Process, refractory insulation, tank
         and vessel levels, steam systems                     Incredible performance at unbelievably low prices.
         and traps, pipes and valves, etc.


         Electrical, unbalanced loads,
         overloaded systems, wiring mistakes
                                                              Fluke. Not just infrared, infrared you can use.®
         or component failure, etc.




                               IR-Fusion® Technology, standard on ALL Fluke thermal imagers
                               More than picture in picture                        Not all fusion is created equal
                               Infrared images alone can be difficult to under-    Don’t be fooled by imitators. Patented IR-Fusion
                               stand, which is why Fluke pioneered IR-Fusion,      is the only solution with physical parallax cor-
                               a revolutionary marriage of visible and infrared    rection, enabling the perfect alignment and
                               images never before seen in commercial or           blending of both infrared and visible images.
                               industrial thermal imagers. Automatically           While many manufacturers have attempted to
                               capturing a visible image with every infrared       duplicate Fluke IR-Fusion, none have been able
                               image allows to you always know exactly what        to match it. Turn to Fluke IR-Fusion to deliver the
                               you’re looking at.                                  industry’s best thermal images.
Detailed specifications
                                                          Ti32                                          Ti25                                          Ti10
Temperature
Temperature measurement range
                                         -20 °C to +600 °C (-4 °F to +1112 °F)           -20 °C to +350 °C (-4 °F to +662 °F)         -20 °C to +250 °C (-4 °F to +482 °F)
(not calibrated below -10 °C)
Temperature measurement                                                                                                                 ± 5 °C or 5 % (at 25 °C nominal,
                                                       ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
accuracy                                                                                                                                     whichever is greater)
On-screen emissivity correction                                                    Yes                                                                 —
On-screen reflected background
                                                                                   Yes                                                                  —
temperature compensation
On-screen transmission correction                         Yes                                                                    —
Imaging performance
Image capture frequency                  9 Hz refresh rate or 60 Hz refresh rate
                                                                                                                         9 Hz refresh rate
                                           depending upon model variation
Detector type                           320 X 240 Focal Plane Array, uncooled
                                                                                                     160 X 120 Focal Plane Array, uncooled microbolometer
                                                    microbolometer
Thermal sensitivity (NETD)              ≤ 0.05 °C at 30 °C target temp. (50 mK)          ≤ 0.1 °C at 30 °C target temp. (100 mK)       ≤ 0.2 °C at 30 °C target temp. (200 mK)
Infrared spectral band                                                                         7.5 µm to 14 µm (long wave)
Visual (visible light) camera            Industrial performance 2.0 megapixel                                     Industrial performance 1.3 megapixel
    Minimum focus distance                                                                         46 cm (approx. 18 in)
Standard infrared lens type
    Field of view                                                                                       23 ° x 17 °
    Spatial resolution (IFOV)                            1.25 mRad                                       2.5 mRad                                     2.5 mRad
    Minimum focus distance                                                                          15 cm (approx. 6 in)
Optional telephoto infrared lens type
    Field of view                                       11.5 ° x 8.7 °                                                              —
    Spatial resolution (IFOV)                            0.63 mRad                                                                  —
    Minimum focus distance                         45 cm (approx. 18 in)                                                            —
Optional wide-angle infrared lens type
    Field of view                                        46 ° x 34 °                                                                —
    Spatial resolution (IFOV)                            2.50 mRad                                                                  —
    Minimum focus distance                         7.5 cm (approx. 3 in)                                                            —
Focus mechanism                                                                       Manual, one-handed Smart Focus capability
Image presentation
Palettes
    Standard                               Ironbow, Blue-Red, High Contrast,
                                                                                            Ironbow, Blue-Red, High Contrast,                    Ironbow, Blue-Red,
                                           Amber, Amber Inverted, Hot Metal,
                                                                                               Amber, Hot Metal, Grayscale                    High Contrast, Grayscale
                                              Grayscale, Grayscale Inverted
    Ultra Contrast™                   Ironbow Ultra, Blue-Red Ultra, High Con-
                                       trast Ultra, Amber Ultra, Amber Inverted
                                                                                                                                    —
                                        Ultra, Hot Metal Ultra, Grayscale Ultra,
                                                 Grayscale Inverted Ultra
Level and span                                                                Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual
                                                                                   Yes                                                                     —
and auto modes
Fast auto-rescale in manual mode                                                   Yes                                                                     —
Minimum span (in manual mode)                                                 2.5 °C (4.5 °F)                                                         5 °C (9 °F)
Minimum span (in auto mode)                                                     5 °C (9 °F)                                                          10 °C (18 °F)
IR-Fusion® information
Automatically aligned (parallax
                                                                                                            Yes
corrected) visual and IR blending
    Picture-In-Picture (PIP)                       Three levels of on-screen IR blending displayed in center of LCD                     100 % IR displayed in center of LCD
    Full screen infrared                                 Three levels of on-screen IR blending displayed on LCD                              100 % IR displayed on LCD
Color alarms (temperature alarms)     High-temperature alarm (user-selectable)                                                      —
Voice annotation                          60 seconds maximum recording time per image; reviewable playback on imager                                       —
Image capture and data storage
                                           The Ti32 allows user to adjust palette,
                                                                                           The Ti25 allows user to adjust palette,
                                       blending, level, span, IR-Fusion® mode,
                                                                                        blending, level, span, IR-Fusion® mode,
                                          emissivity, and reflected background
                                                                                          emissivity, and reflected background                               —
                                             temperature compensation, and
                                                                                       temperature compensation on a captured
                                        transmission correction on a captured
                                                                                                 image before it is stored.
                                                image before it is stored.
Image capture, review, save
                                                                               One-handed image capture, review, and save capability
mechanism
Storage medium                              SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with
                                              60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via
                                                                                         included multi-format USB card reader
File formats                               Non-radiometric (.bmp) or (.jpeg) or
                                                                                                            Non-radiometric (.bmp) or fully-radiometric (.is2)
                                                  fully-radiometric (.is2)
                                            No analysis software required for
                                                                                                  No analysis software required for non-radiometic bitmap (.bmp) files
                                        non-radiometric (.bmp and .jpeg) files
Export file formats w/SmartView®
                                                                                BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
software
Memory review                                Thumbnail view navigation and
                                                                                                                Sequential image navigation and review
                                                      review selection

2 Fluke Corporation     Ti32, Ti25 and Ti10 Industrial Thermal Imagers
General specifications
Operating temperature         -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature           -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity             10 % to 95 % non-condensing
Display                       9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
Controls and adjustments      User selectable temperature scale (°C/°F)
                              Language selection
                              Time/Date set
                              Emissivity selection (Ti32 and Ti25 only)
                              Reflected background temperature compensation (Ti32 and Ti25 only)
                              Transmission correction (Ti32 only)
                              User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software)
                              (Ti32 and Ti25 only)
                              High temperature alarm (Ti32 only)
                              User selectable backlight: “Full Bright” or “Auto”
                              Information display preference (Ti32 only)
Software                      SmartView® full analysis and reporting software included
Batteries                     Ti32: Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
                              Ti25 and Ti10: Internal rechargeable battery pack (included)
Battery life                  Ti32: Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD)
                              Ti25 and Ti10: Three to four hours continuous use (assumes 50 % brightness of LCD)
Battery charge time           2.5 hours to full charge
AC battery charging           Ti32: Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included.
                              Optional 12 V automotive charging adapter.
                              Ti25 and Ti10: AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned
                              off, ac mains adapters included.
AC operation                  AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
Power saving                  Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity
Safety standards              CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006
C Tick                        IEC/EN 61326-1
US FCC                        CFR 47, Part 15 Class B
Vibration                     0.03 g2/Hz (3.8 grms), IEC 68-2-6
Shock                         25 g, IEC 68-2-29
Drop                          Ti32: 2 meter (6.5 feet) with standard lens, Ti25 and Ti10: 2 meter (6.5 feet)
Size (H x W x L)              Ti32: 27.7 cm x 12.2 cm x 17.0 cm (10.9 in x 4.8 in x 6.7 in), Ti25 and Ti10: 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in)
Weight (battery included)     Ti32 1.05 kg (2.3 lb), Ti25 and Ti10: 1.2 kg (2.6 lb)
Enclosure rating              IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty                      Two-years (standard)
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported Languages           Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish,
                              Swedish, Traditional Chinese, and Turkish




  Ordering information
  FLK-Ti32 9Hz Industrial-Commercial Thermal Imager, 9 Hz
  FLK-Ti32 60Hz Industrial-Commercial Thermal Imager, 60 Hz
  Included with Ti32 models
  Thermal imager with standard infrared lens; ac power supply and battery pack charger (including
  mains adapters); two, rugged lithium ion smart battery packs; SD memory card; multi-format USB
  memory card reader for downloading images into your computer; SmartView® software with free
  software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap;                   Fluke. Not just infrared.
  printed users manual; warranty registration card; interactive training DVD.                                                 Infrared you can use.™
  FLK-Ti25 9Hz Thermal Imager
                                                                                                                       Fluke Corporation
  FLK-Ti10 9Hz Thermal Imager                                                                                          PO Box 9090, Everett, WA 98206 U.S.A.
  Included with Ti25 and Ti10 models                                                                                   Fluke Europe B.V.
  Thermal imager with standard infrared lens, ac power supply/battery charger (including mains                         PO Box 1186, 5602 BD
  adapters); SD memory card; multi-format USB memory card reader for downloading images into                           Eindhoven, The Netherlands
  your computer; SmartView® software with free software upgrades for life; rugged, hard carrying                       For more information call:
  case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card;                   In the U.S.A. (800) 443-5853 or
  interactive training DVD.                                                                                            Fax (425) 446-5116
                                                                                                                       In Europe/M-East/Africa +31 (0) 40 2675 200 or
  Optional accessories                                                                                                 Fax +31 (0) 40 2675 222
  FLK-LENS/TELE1 Telephoto Infrared Lens (Ti32 only)                                                                   In Canada (800)-36-FLUKE or
                                                                                                                       Fax (905) 890-6866
  FLK-LENS/WIDE1 Wide-angle Infrared Lens (Ti32 only)                                                                  From other countries +1 (425) 446-5500 or
  TI-CAR-CHARGER Thermal Imager Vehicle Charger                                                                        Fax +1 (425) 446-5116
  TI-VISOR Thermal Imager Visor                                                                                        Web access: http://www.fluke.com
  BOOK-ITP Introduction to Thermography Principles Book                                                                ©2009 Fluke Corporation.
                                                                                                                       Specifications subject to change without notice.
  TI-TRIPOD Tripod Mounting Base Accessory                                                                             Printed in U.S.A. 8/2009 3467124D D-EN-N

                                                                                                                       Modification of this document is not permitted
                                                                                                                       without written permission from Fluke Corporation.

3 Fluke Corporation    Ti32, Ti25 and Ti10 Industrial Thermal Imagers

More Related Content

What's hot

US Cove Light AC HO / HO Graze Specification
US Cove Light AC HO / HO Graze SpecificationUS Cove Light AC HO / HO Graze Specification
US Cove Light AC HO / HO Graze Specificationvalorlighting
 
Testo 552 vacuum gauge
Testo 552 vacuum gaugeTesto 552 vacuum gauge
Testo 552 vacuum gaugeTesto Limited
 
Study on Droplet-based Liquid Cooling of an Hotspot using Digital Microfluidics
Study on Droplet-based Liquid Cooling of an Hotspot using Digital MicrofluidicsStudy on Droplet-based Liquid Cooling of an Hotspot using Digital Microfluidics
Study on Droplet-based Liquid Cooling of an Hotspot using Digital Microfluidicsbgshreyas85
 
Testo thermography industry_2012
Testo thermography industry_2012Testo thermography industry_2012
Testo thermography industry_2012Testo Limited
 
Izinova display-solution 2013
Izinova  display-solution 2013Izinova  display-solution 2013
Izinova display-solution 2013openerp1
 
Testo 635 datasheet 2012
Testo 635 datasheet 2012Testo 635 datasheet 2012
Testo 635 datasheet 2012Testo Limited
 
Testo - Thermal Imaging - Industry
Testo - Thermal Imaging - IndustryTesto - Thermal Imaging - Industry
Testo - Thermal Imaging - IndustryTesto Limited
 
Detectors for light microscopy
Detectors for light microscopyDetectors for light microscopy
Detectors for light microscopyandortech
 
Instructions | Hikmicro Thunder | Optics Trade
Instructions | Hikmicro Thunder | Optics TradeInstructions | Hikmicro Thunder | Optics Trade
Instructions | Hikmicro Thunder | Optics TradeOptics-Trade
 
Mpt presentation by manish abraham
Mpt presentation by manish abrahamMpt presentation by manish abraham
Mpt presentation by manish abrahamManish Abraham
 
Auto Kerato Refracto Tonometer
Auto Kerato Refracto TonometerAuto Kerato Refracto Tonometer
Auto Kerato Refracto Tonometerscorbion
 

What's hot (18)

US Cove Light AC HO / HO Graze Specification
US Cove Light AC HO / HO Graze SpecificationUS Cove Light AC HO / HO Graze Specification
US Cove Light AC HO / HO Graze Specification
 
Testo 552 vacuum gauge
Testo 552 vacuum gaugeTesto 552 vacuum gauge
Testo 552 vacuum gauge
 
Study on Droplet-based Liquid Cooling of an Hotspot using Digital Microfluidics
Study on Droplet-based Liquid Cooling of an Hotspot using Digital MicrofluidicsStudy on Droplet-based Liquid Cooling of an Hotspot using Digital Microfluidics
Study on Droplet-based Liquid Cooling of an Hotspot using Digital Microfluidics
 
Testo thermography industry_2012
Testo thermography industry_2012Testo thermography industry_2012
Testo thermography industry_2012
 
Izinova display-solution 2013
Izinova  display-solution 2013Izinova  display-solution 2013
Izinova display-solution 2013
 
Testo 885 datasheet
Testo 885 datasheetTesto 885 datasheet
Testo 885 datasheet
 
Dome Ir Catalouge
Dome Ir CatalougeDome Ir Catalouge
Dome Ir Catalouge
 
Testo 635 datasheet 2012
Testo 635 datasheet 2012Testo 635 datasheet 2012
Testo 635 datasheet 2012
 
Spec Sheet
Spec SheetSpec Sheet
Spec Sheet
 
ecatalog
ecatalogecatalog
ecatalog
 
Gk21 Led light
Gk21 Led lightGk21 Led light
Gk21 Led light
 
Testo - Thermal Imaging - Industry
Testo - Thermal Imaging - IndustryTesto - Thermal Imaging - Industry
Testo - Thermal Imaging - Industry
 
Detectors for light microscopy
Detectors for light microscopyDetectors for light microscopy
Detectors for light microscopy
 
Instructions | Hikmicro Thunder | Optics Trade
Instructions | Hikmicro Thunder | Optics TradeInstructions | Hikmicro Thunder | Optics Trade
Instructions | Hikmicro Thunder | Optics Trade
 
Vt Dat A4 Nov 07 Rev
Vt Dat A4 Nov 07 RevVt Dat A4 Nov 07 Rev
Vt Dat A4 Nov 07 Rev
 
Mpt presentation by manish abraham
Mpt presentation by manish abrahamMpt presentation by manish abraham
Mpt presentation by manish abraham
 
Ms4400
Ms4400Ms4400
Ms4400
 
Auto Kerato Refracto Tonometer
Auto Kerato Refracto TonometerAuto Kerato Refracto Tonometer
Auto Kerato Refracto Tonometer
 

Viewers also liked (20)

El rol del formador 2
El rol del formador 2El rol del formador 2
El rol del formador 2
 
мистецтво фотографії
мистецтво фотографіїмистецтво фотографії
мистецтво фотографії
 
Acta 2011 mar 08
Acta 2011 mar 08Acta 2011 mar 08
Acta 2011 mar 08
 
Ellis island
Ellis islandEllis island
Ellis island
 
Daniela pict
Daniela pictDaniela pict
Daniela pict
 
ProtectIV
ProtectIVProtectIV
ProtectIV
 
Beta testing with CI
Beta testing with CIBeta testing with CI
Beta testing with CI
 
1 dissertation guidelines_v3_2011_cohort
1 dissertation guidelines_v3_2011_cohort1 dissertation guidelines_v3_2011_cohort
1 dissertation guidelines_v3_2011_cohort
 
ITMI Symposium 2013 brochure
ITMI Symposium 2013 brochureITMI Symposium 2013 brochure
ITMI Symposium 2013 brochure
 
NewcastleGateshead Initiative partner update meeting 25 Feb 2016
NewcastleGateshead Initiative partner update meeting 25 Feb 2016NewcastleGateshead Initiative partner update meeting 25 Feb 2016
NewcastleGateshead Initiative partner update meeting 25 Feb 2016
 
2011-12 hsaa - may 26-11
2011-12 hsaa - may 26-112011-12 hsaa - may 26-11
2011-12 hsaa - may 26-11
 
2011 05-28 pam marshall
2011 05-28 pam marshall2011 05-28 pam marshall
2011 05-28 pam marshall
 
scc-apr-21-2011
scc-apr-21-2011scc-apr-21-2011
scc-apr-21-2011
 
10 doosa besar
10 doosa besar10 doosa besar
10 doosa besar
 
My sql
My sqlMy sql
My sql
 
Evaluation - 1
Evaluation - 1Evaluation - 1
Evaluation - 1
 
Evaluation- 1
Evaluation- 1Evaluation- 1
Evaluation- 1
 
Confiance Newsletter:Take it to the bank
Confiance Newsletter:Take it to the bankConfiance Newsletter:Take it to the bank
Confiance Newsletter:Take it to the bank
 
Smoking
SmokingSmoking
Smoking
 
Fisk escabeche
Fisk escabecheFisk escabeche
Fisk escabeche
 

Similar to Ti32 Data Sheet

Fluke Industrial Thermal Imagers
Fluke Industrial Thermal ImagersFluke Industrial Thermal Imagers
Fluke Industrial Thermal ImagersFlukeinMalta
 
Technical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_en
Technical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_enTechnical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_en
Technical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_enPT. Siwali Swantika
 
Technical Data Fluke Ti300+ Thermal Camera (Datasheet)
Technical Data Fluke Ti300+ Thermal Camera (Datasheet)Technical Data Fluke Ti300+ Thermal Camera (Datasheet)
Technical Data Fluke Ti300+ Thermal Camera (Datasheet)PT. Siwali Swantika
 
FLIR T420, FLIR T420 IR Camera FLIR T 420
FLIR T420, FLIR T420 IR Camera FLIR T 420FLIR T420, FLIR T420 IR Camera FLIR T 420
FLIR T420, FLIR T420 IR Camera FLIR T 420raymondbaxterrdx
 
Katalog fluke-ir-and-contact-thermometers-by-tridinamika
Katalog fluke-ir-and-contact-thermometers-by-tridinamikaKatalog fluke-ir-and-contact-thermometers-by-tridinamika
Katalog fluke-ir-and-contact-thermometers-by-tridinamikaPT. Tridinamika Jaya Instrument
 
Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300
Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300
Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300PT. Siwali Swantika
 
Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
 
Industrial Thermal Imagers
Industrial Thermal ImagersIndustrial Thermal Imagers
Industrial Thermal ImagersPremier Farnell
 
Katalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamika
Katalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamikaKatalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamika
Katalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamikaPT. Tridinamika Jaya Instrument
 
FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420
FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420
FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420raymondbaxterrdx
 
FLIR T 640 Thermal Imaging Camera
FLIR T 640 Thermal Imaging CameraFLIR T 640 Thermal Imaging Camera
FLIR T 640 Thermal Imaging Camerabryanafranciswrm
 
Smoke detection in challenging environments
Smoke detection in challenging environmentsSmoke detection in challenging environments
Smoke detection in challenging environments亮儒 黃
 
Technical Data Fluke TiX Series Thermal Imager
Technical Data Fluke TiX Series Thermal ImagerTechnical Data Fluke TiX Series Thermal Imager
Technical Data Fluke TiX Series Thermal ImagerPT. Siwali Swantika
 
What do you need to Measure
What do you need to MeasureWhat do you need to Measure
What do you need to MeasurePaul Alger
 

Similar to Ti32 Data Sheet (20)

Ti32
Ti32Ti32
Ti32
 
Fluke Industrial Thermal Imagers
Fluke Industrial Thermal ImagersFluke Industrial Thermal Imagers
Fluke Industrial Thermal Imagers
 
Katalog fluke-industrial-thermal-imagers
Katalog fluke-industrial-thermal-imagersKatalog fluke-industrial-thermal-imagers
Katalog fluke-industrial-thermal-imagers
 
Technical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_en
Technical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_enTechnical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_en
Technical Data Fluke Ti401 PRO, Ti480, TiX501, TiX580_en
 
Technical Data Fluke Ti300+ Thermal Camera (Datasheet)
Technical Data Fluke Ti300+ Thermal Camera (Datasheet)Technical Data Fluke Ti300+ Thermal Camera (Datasheet)
Technical Data Fluke Ti300+ Thermal Camera (Datasheet)
 
Katalog fluke-building-thermal-imagers
Katalog fluke-building-thermal-imagersKatalog fluke-building-thermal-imagers
Katalog fluke-building-thermal-imagers
 
FLIR T420, FLIR T420 IR Camera FLIR T 420
FLIR T420, FLIR T420 IR Camera FLIR T 420FLIR T420, FLIR T420 IR Camera FLIR T 420
FLIR T420, FLIR T420 IR Camera FLIR T 420
 
Katalog fluke-ir-and-contact-thermometers-by-tridinamika
Katalog fluke-ir-and-contact-thermometers-by-tridinamikaKatalog fluke-ir-and-contact-thermometers-by-tridinamika
Katalog fluke-ir-and-contact-thermometers-by-tridinamika
 
Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300
Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300
Technical Data Fluke Ti480, Ti450, Ti400 dan Ti300
 
Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 59 Max. Hubungi PT. Siwali Swantika 021-45850618
 
Industrial Thermal Imagers
Industrial Thermal ImagersIndustrial Thermal Imagers
Industrial Thermal Imagers
 
FLIR T640 Infrared Camera
FLIR T640 Infrared CameraFLIR T640 Infrared Camera
FLIR T640 Infrared Camera
 
Katalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamika
Katalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamikaKatalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamika
Katalog trotec-infrared-camera-thermal-imager-thermography-ic-series-tridinamika
 
FLIR T 640 IR Camera
FLIR T 640 IR CameraFLIR T 640 IR Camera
FLIR T 640 IR Camera
 
FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420
FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420
FLIR T420, FLIR T420 Thermal Imaging Camera FLIR T 420
 
FLIR T 640 Thermal Imaging Camera
FLIR T 640 Thermal Imaging CameraFLIR T 640 Thermal Imaging Camera
FLIR T 640 Thermal Imaging Camera
 
Smoke detection in challenging environments
Smoke detection in challenging environmentsSmoke detection in challenging environments
Smoke detection in challenging environments
 
Technical Data Fluke TiX Series Thermal Imager
Technical Data Fluke TiX Series Thermal ImagerTechnical Data Fluke TiX Series Thermal Imager
Technical Data Fluke TiX Series Thermal Imager
 
Rf360
Rf360Rf360
Rf360
 
What do you need to Measure
What do you need to MeasureWhat do you need to Measure
What do you need to Measure
 

More from FlukeinMalta

ScopeMeter 190 Series II
ScopeMeter 190 Series IIScopeMeter 190 Series II
ScopeMeter 190 Series IIFlukeinMalta
 
Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011FlukeinMalta
 
Ti32, TiR32 User Manual
Ti32, TiR32 User ManualTi32, TiR32 User Manual
Ti32, TiR32 User ManualFlukeinMalta
 
Save Money with Fluke Thermal Imagers
Save Money with Fluke Thermal ImagersSave Money with Fluke Thermal Imagers
Save Money with Fluke Thermal ImagersFlukeinMalta
 

More from FlukeinMalta (6)

ScopeMeter 190 Series II
ScopeMeter 190 Series IIScopeMeter 190 Series II
ScopeMeter 190 Series II
 
Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011Fluke Test Tools Catalog 2010/2011
Fluke Test Tools Catalog 2010/2011
 
Ti32, TiR32 User Manual
Ti32, TiR32 User ManualTi32, TiR32 User Manual
Ti32, TiR32 User Manual
 
Save Money with Fluke Thermal Imagers
Save Money with Fluke Thermal ImagersSave Money with Fluke Thermal Imagers
Save Money with Fluke Thermal Imagers
 
Ti25 manual
Ti25 manualTi25 manual
Ti25 manual
 
Ti25 brochure
Ti25 brochureTi25 brochure
Ti25 brochure
 

Ti32 Data Sheet

  • 1. Fluke Industrial Thermal Imagers Models: Ti32, Ti25 and Ti10 Technical Data High performance thermal imagers have never been this affordable. This rugged. Or, this easy to use … until now. We, at Fluke, are never satisfied leaving the best tools in the hands of the elite, which is why we recently added a new member to our thermal imaging family. The new Fluke Ti32 combines a powerful 320x240 sensor into the award winning, rugged design of the Ti25 and Ti10, delivering the first industrial grade, high performance thermal imager. The result is strikingly crisp, detailed images that, blended with our patented IR-Fusion®, are sure to make a lasting impression. Don’t take our word for it—see it yourself! Ti32 Fluke thermal imagers are designed, tested, and manufactured in the USA, and feature a two year warranty. Work in a harsh environment? Don’t worry. These meet the stringent quality standards that Fluke prod- ucts are known for worldwide. Able to withstand a 2 meter (6.5 foot) Ti25 drop, they also meet the requirements for an IP54 rating against dust and moisture. Industrial, mechanical, For added versatility and special applications, the Ti32 includes two electromechanical and general field-swappable, rechargeable batteries. Use the optional telephoto and building maintenance. wide-angle lenses to bring distant and wide views into sharp focus. Process, refractory insulation, tank and vessel levels, steam systems Incredible performance at unbelievably low prices. and traps, pipes and valves, etc. Electrical, unbalanced loads, overloaded systems, wiring mistakes Fluke. Not just infrared, infrared you can use.® or component failure, etc. IR-Fusion® Technology, standard on ALL Fluke thermal imagers More than picture in picture Not all fusion is created equal Infrared images alone can be difficult to under- Don’t be fooled by imitators. Patented IR-Fusion stand, which is why Fluke pioneered IR-Fusion, is the only solution with physical parallax cor- a revolutionary marriage of visible and infrared rection, enabling the perfect alignment and images never before seen in commercial or blending of both infrared and visible images. industrial thermal imagers. Automatically While many manufacturers have attempted to capturing a visible image with every infrared duplicate Fluke IR-Fusion, none have been able image allows to you always know exactly what to match it. Turn to Fluke IR-Fusion to deliver the you’re looking at. industry’s best thermal images.
  • 2. Detailed specifications Ti32 Ti25 Ti10 Temperature Temperature measurement range -20 °C to +600 °C (-4 °F to +1112 °F) -20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F) (not calibrated below -10 °C) Temperature measurement ± 5 °C or 5 % (at 25 °C nominal, ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) accuracy whichever is greater) On-screen emissivity correction Yes — On-screen reflected background Yes — temperature compensation On-screen transmission correction Yes — Imaging performance Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate 9 Hz refresh rate depending upon model variation Detector type 320 X 240 Focal Plane Array, uncooled 160 X 120 Focal Plane Array, uncooled microbolometer microbolometer Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C target temp. (50 mK) ≤ 0.1 °C at 30 °C target temp. (100 mK) ≤ 0.2 °C at 30 °C target temp. (200 mK) Infrared spectral band 7.5 µm to 14 µm (long wave) Visual (visible light) camera Industrial performance 2.0 megapixel Industrial performance 1.3 megapixel Minimum focus distance 46 cm (approx. 18 in) Standard infrared lens type Field of view 23 ° x 17 ° Spatial resolution (IFOV) 1.25 mRad 2.5 mRad 2.5 mRad Minimum focus distance 15 cm (approx. 6 in) Optional telephoto infrared lens type Field of view 11.5 ° x 8.7 ° — Spatial resolution (IFOV) 0.63 mRad — Minimum focus distance 45 cm (approx. 18 in) — Optional wide-angle infrared lens type Field of view 46 ° x 34 ° — Spatial resolution (IFOV) 2.50 mRad — Minimum focus distance 7.5 cm (approx. 3 in) — Focus mechanism Manual, one-handed Smart Focus capability Image presentation Palettes Standard Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, Amber, Amber Inverted, Hot Metal, Amber, Hot Metal, Grayscale High Contrast, Grayscale Grayscale, Grayscale Inverted Ultra Contrast™ Ironbow Ultra, Blue-Red Ultra, High Con- trast Ultra, Amber Ultra, Amber Inverted — Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual Yes — and auto modes Fast auto-rescale in manual mode Yes — Minimum span (in manual mode) 2.5 °C (4.5 °F) 5 °C (9 °F) Minimum span (in auto mode) 5 °C (9 °F) 10 °C (18 °F) IR-Fusion® information Automatically aligned (parallax Yes corrected) visual and IR blending Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center of LCD 100 % IR displayed in center of LCD Full screen infrared Three levels of on-screen IR blending displayed on LCD 100 % IR displayed on LCD Color alarms (temperature alarms) High-temperature alarm (user-selectable) — Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager — Image capture and data storage The Ti32 allows user to adjust palette, The Ti25 allows user to adjust palette, blending, level, span, IR-Fusion® mode, blending, level, span, IR-Fusion® mode, emissivity, and reflected background emissivity, and reflected background — temperature compensation, and temperature compensation on a captured transmission correction on a captured image before it is stored. image before it is stored. Image capture, review, save One-handed image capture, review, and save capability mechanism Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader File formats Non-radiometric (.bmp) or (.jpeg) or Non-radiometric (.bmp) or fully-radiometric (.is2) fully-radiometric (.is2) No analysis software required for No analysis software required for non-radiometic bitmap (.bmp) files non-radiometric (.bmp and .jpeg) files Export file formats w/SmartView® BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF software Memory review Thumbnail view navigation and Sequential image navigation and review review selection 2 Fluke Corporation Ti32, Ti25 and Ti10 Industrial Thermal Imagers
  • 3. General specifications Operating temperature -10 °C to +50 °C (14 °F to 122 °F) Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries Relative humidity 10 % to 95 % non-condensing Display 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover Controls and adjustments User selectable temperature scale (°C/°F) Language selection Time/Date set Emissivity selection (Ti32 and Ti25 only) Reflected background temperature compensation (Ti32 and Ti25 only) Transmission correction (Ti32 only) User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software) (Ti32 and Ti25 only) High temperature alarm (Ti32 only) User selectable backlight: “Full Bright” or “Auto” Information display preference (Ti32 only) Software SmartView® full analysis and reporting software included Batteries Ti32: Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level Ti25 and Ti10: Internal rechargeable battery pack (included) Battery life Ti32: Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD) Ti25 and Ti10: Three to four hours continuous use (assumes 50 % brightness of LCD) Battery charge time 2.5 hours to full charge AC battery charging Ti32: Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. Ti25 and Ti10: AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains adapters included. AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006 C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Class B Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6 Shock 25 g, IEC 68-2-29 Drop Ti32: 2 meter (6.5 feet) with standard lens, Ti25 and Ti10: 2 meter (6.5 feet) Size (H x W x L) Ti32: 27.7 cm x 12.2 cm x 17.0 cm (10.9 in x 4.8 in x 6.7 in), Ti25 and Ti10: 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in) Weight (battery included) Ti32 1.05 kg (2.3 lb), Ti25 and Ti10: 1.2 kg (2.6 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard) Recommended calibration cycle Two-years (assumes normal operation and normal aging) Supported Languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish Ordering information FLK-Ti32 9Hz Industrial-Commercial Thermal Imager, 9 Hz FLK-Ti32 60Hz Industrial-Commercial Thermal Imager, 60 Hz Included with Ti32 models Thermal imager with standard infrared lens; ac power supply and battery pack charger (including mains adapters); two, rugged lithium ion smart battery packs; SD memory card; multi-format USB memory card reader for downloading images into your computer; SmartView® software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; Fluke. Not just infrared. printed users manual; warranty registration card; interactive training DVD. Infrared you can use.™ FLK-Ti25 9Hz Thermal Imager Fluke Corporation FLK-Ti10 9Hz Thermal Imager PO Box 9090, Everett, WA 98206 U.S.A. Included with Ti25 and Ti10 models Fluke Europe B.V. Thermal imager with standard infrared lens, ac power supply/battery charger (including mains PO Box 1186, 5602 BD adapters); SD memory card; multi-format USB memory card reader for downloading images into Eindhoven, The Netherlands your computer; SmartView® software with free software upgrades for life; rugged, hard carrying For more information call: case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card; In the U.S.A. (800) 443-5853 or interactive training DVD. Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Optional accessories Fax +31 (0) 40 2675 222 FLK-LENS/TELE1 Telephoto Infrared Lens (Ti32 only) In Canada (800)-36-FLUKE or Fax (905) 890-6866 FLK-LENS/WIDE1 Wide-angle Infrared Lens (Ti32 only) From other countries +1 (425) 446-5500 or TI-CAR-CHARGER Thermal Imager Vehicle Charger Fax +1 (425) 446-5116 TI-VISOR Thermal Imager Visor Web access: http://www.fluke.com BOOK-ITP Introduction to Thermography Principles Book ©2009 Fluke Corporation. Specifications subject to change without notice. TI-TRIPOD Tripod Mounting Base Accessory Printed in U.S.A. 8/2009 3467124D D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation. 3 Fluke Corporation Ti32, Ti25 and Ti10 Industrial Thermal Imagers