3. KITCHEN
DINING
15'-0" x 15'-10"
12'-8" x 15'-9"
LIVING ROOM
15'-0" x 19'-6"
FAMILY ROOM
15'-0" x 21'-0"
GARAGE
21'-6" x 30'-0"
GUEST BEDROOM
12'-0" x 11'-6"
BATHROOM
8'-2" x 5'-9"
NOOK
12'-6" x 13'-11"
FOYER
12'-0" x 12'-0"
UTILITY
9'-3" x 6'-6"
OVEN
FR. FRZ.
PANT.
DESK
CLOSET
CLOSET
FP
BAR
LAUNDRY CHUTE
DN
UP
DN
LINE OF FLOOR ABOVE
DW
LINE OF FLOOR ABOVE
A
B
C
D
E
F
2' - 0" 13' - 6" 12' - 6" 15' - 6" 22' - 6"
9'-0"6'-6"1'-11"20'-7"10'-6"2'-0"7'-6"
C:UsersEricDesktop4115Braemar4115BraemarBoulevard_EM2.rvt
Permit Application Package
Interior Alterations - 2-Storey Residential Building
4115 E. Braemar Road, N. Vancouver, B.C.
4. Permit Application Package
Interior Alterations - 2-Storey Residential Building
6737 Crabapple Drive, Whistler, B.C.
UP
UP
UP
4
DCA
3
2
1
B
KITCHEN
10'-0" x 8'-6"
LIVING/ DINING
13'-2" x 16'-9"
BATHROOM
8'-0" x 5'-0"
KITCHEN
8'-0" x 9'-11"
LIVING
19'-0" x 10'-0"
DINING
8'-4" x 11'-6"
BEDROOM
11'-3" x 8'-6"
BATHROOM
8'-0" x 5'-0"
FP
CLOSET
CLOSET
STORAGE
ricDesktopactive.FTW.107-6737Crabapple-Whistler6737Crabapple_EM.rvt
5. Permit Application Package
2nd Storey Addition - Single Storey Residential Building
4611 Westlawn Drive, Burnaby, B.C.
Project:
Drawing:
Scale: DWG. NO:
Copyright reserved. This design and drawing
is the exclusive property of METRIC and
cannot be used for any purpose without the
written consent of the Architect.
This drawing is not to be used for construction
until issued for that purpose by the Architect.
Prior to commencement of the work the
contractor shall: verify all dimensions, datums
and levels to identify any errors or omissions;
ascertain any discrepencies between this
drawing and the full contract documents; and,
bring these items to the attention of the
Architect for clarification.
:
SUBMISSION
No. Date Description
Project Status:
Architectural Design: Mark Peers
Technician: Cameron Hardisty
Contacts:
Tuscan Developments Inc: 604-542-9114
www.tuscandevelopments.com
Residence for:
Radu & Larisa Beschea
15/12/20148:49:51AMC:UsersUserDocumentsWorkTuscanDevelopmentsTD.005-BescheaResidence–6335BryantSt(Burnaby)6335BryantStreet_2.2_BP.rvt
PERSPECTIVE
TD.005
RENOVATION & 2nd FLOOR
ADDITION
Tuscan Developments
6335 Bryant Street - Burnaby, BC
2 2014-12-15 - RE-ISSUED FOR PERMIT
1- 2014-10-20 - ISSUED FOR PERMIT
Re-Issued for Permit
REVISION
No. Date Description
6. BASEMENT
372'-4 13/16"
MAIN FLOOR
380'-4 13/16"
UPPER FLOOR
389'-10 13/16"
MAX. HEIGHT
399'-6 3/8"
t/o EXISTING WALL
387'-4 13/16"
4 123
PROPOSED ROOF ASSEMBLY
TORCH-ON ROOFING FINISH
VENTING LAYER (PT WOOD STRAPPING)
ROOFING MEMBRANE
3/4" SHEATHING
ROOF JOIST(SEE STRUCTURAL)
BATT INSULATION (R-28)
6mil POLY VAPOUR BARRIER
1/2" GWB
EXISTING CONC. SOG ASSEMBLY
6" CONC. SOG
6mil POLY VB
GRAVEL BASECOURSE
PROPOSED UPPER FLOOR ASSEMBLY
1.5" CONC. SKIM COAT c/w RADIANT IN-FLOOR HEATING
3/4" PLYWOOD
2x10 TJI (SEE STRUCTURAL)
1/2" GWB
PROPOSED EXTERIOR WALL ASSEMBLY
PROPOSED SIDING (see A.300)
3/4" PT WOOD STRAPPING
2-LAYER BLDG PAPER
1/2" SHEATHING
2x6 WOOD STUD
BATT INSULATION (R-20)
6mil POLY VAPOUR BARRIER
1/2" GWB
PROPOSEDADDITIONEXISTINGSINGLE-FAMILYDWELLING
9'-8"9'-6"8'-0"
19'-2"
1" / 12" 1" / 12"
8'-6"8'-6"7'-0"
UPPER FLOOR
389'-10 13/16"
MINIMUM
1'-6"
1' - 6"
Project:
Drawing:
Copyright reserved. This design and drawing
is the exclusive property of METRIC and
cannot be used for any purpose without the
written consent of the Architect.
This drawing is not to be used for construction
until issued for that purpose by the Architect.
SUBMISSION
No. Date Description
Project Status:
Contacts:
Tuscan Developments Inc: 604-542-9114
www.tuscandevelopments.com
Residence for:
Radu & Larisa Beschea
SECTION
TD.005
RENOVATION & 2nd FLOOR
ADDITION
Tuscan Developments
6335 Bryant Street - Burnaby, BC
2 - 2014-12-15 - RE-ISSUED FOR PERMIT
1- 2014-09-23 - ISSUED TO STRUCTURAL
Re-Issued for Permit
REVISION
No. Date Description
SCALE: 1/2" = 1'-0"
2
WINDOW SEAT DETAIL
BASEMENT
372'-4 13/16"
MAIN FLOOR
380'-4 13/16"
UPPER FLOOR
389'-10 13/16"
t/o EXISTING WALL
387'-4 13/16"
B
1
A.400
ROOF HEIGHT
399'-6 3/8"
NEW HORIZONTAL HARDI-BOARD SIDING
col: CHARCOAL
NEW WOOD TRIM
NEW HORIZONTAL WOOD SIDING
-SANDED + STAINED
PROPOSEDADDITIONPRE-EXISTINGHOME
EXISTING ROOF
PEAK
394'-2"
CA
x2'-0" 6'-0" x4'-0" 6'-0" x2'-0" 6'-0" x2'-0" 6'-0" x2'-0" 6'-0"
x6'-0" 3'-0"
x8'-0" 6'-0"
6'-0" x 6'-0" 5'-0" x 6'-8"
5'-0" x 6'-8"
9'-8"9'-6"8'-0"
NEW RAIL TO MATCH EXISTING & BCBC (LATEST EDITION) PART 9
E/P: 374.69'
E/P: 375.77'
x2'-0" 6'-0" x2'-0" 6'-0"
REMOVE EXISTING STORAGE
ENCLOSURE BELOW DECK
MAIN FLOOR
380'-4 13/16"
UPPER FLOOR
389'-10 13/16"
t/o EXISTING WALL
387'-4 13/16"
B
1
A.400
ROOF HEIGHT
399'-6 3/8"
NEW HORIZONTAL HARDI-BOARD SIDING
col: CHARCOAL
NEW WOOD TRIM
NEW HORIZONTAL WOOD SIDING
-SANDED + STAINED
PRE-EXISTINGHOMEPROPOSEDADDITION
EXISTING BRICK SIDING
-PAINTED CHARCOAL
NEW METAL + GLASS ENTRY DOOR
NEW ROOF
EXISTING ROOF
PEAK
394'-2"
C A
x2'-6" 3'-6" x4'-6" 3'-6" x4'-6" 3'-6"
x3'-0" 3'-0"
x6'-0" 4'-8"x12'-0" 4'-8"
4'-0" x 6'-0"
4'-0" x 6'-8"
E/P: 378.97'E/P: 378.61'
PlotDate:15/12/201412:37:09PMC:UsersUserDocumentsWorkTuscanDevelopmentsTD.005-BescheaResidence–6335BryantSt(Burnaby)6335BryantStreet_2.2_BP.rvt
SCALE: 1/4" = 1'-0"
1
North
SCALE: 1/4" = 1'-0"
2
South
Permit Application Package
2nd Storey Addition - Single Storey Residential Building
4611 Westlawn Drive, Burnaby, B.C.