SlideShare a Scribd company logo

More Related Content

What's hot (20)

60001
6000160001
60001
 
240
240240
240
 
65040W
65040W65040W
65040W
 
65023
6502365023
65023
 
92001
9200192001
92001
 
STC
STCSTC
STC
 
SHBxR
SHBxRSHBxR
SHBxR
 
121
121121
121
 
250
250250
250
 
220
220220
220
 
5303
53035303
5303
 
3510
35103510
3510
 
9423
94239423
9423
 
SEB
SEBSEB
SEB
 
60060
6006060060
60060
 
9303
93039303
9303
 
614
614614
614
 
1042
10421042
1042
 
60058
6005860058
60058
 
HBB
HBBHBB
HBB
 

Viewers also liked (14)

RINSTRUM X320
RINSTRUM X320RINSTRUM X320
RINSTRUM X320
 
5223
52235223
5223
 
9102 MOUNT
9102 MOUNT9102 MOUNT
9102 MOUNT
 
BCOM
BCOMBCOM
BCOM
 
9123
91239123
9123
 
SQB
SQBSQB
SQB
 
SBC
SBCSBC
SBC
 
5203
52035203
5203
 
5123
51235123
5123
 
RINSTRUM X320
RINSTRUM X320RINSTRUM X320
RINSTRUM X320
 
KITCHEN EQUIPMENTS
KITCHEN EQUIPMENTSKITCHEN EQUIPMENTS
KITCHEN EQUIPMENTS
 
IW2P1
IW2P1IW2P1
IW2P1
 
SSB MOUNT
SSB MOUNTSSB MOUNT
SSB MOUNT
 
LPS
LPSLPS
LPS
 

Similar to ASC (20)

1130
11301130
1130
 
60051
6005160051
60051
 
60063
6006360063
60063
 
HPS
HPSHPS
HPS
 
DSR
DSRDSR
DSR
 
1030
10301030
1030
 
1033
10331033
1033
 
SQB-H
SQB-HSQB-H
SQB-H
 
355
355355
355
 
CSP-M
CSP-MCSP-M
CSP-M
 
3520
35203520
3520
 
9103
91039103
9103
 
120
120120
120
 
1242
12421242
1242
 
1260
12601260
1260
 
65058-TSA
65058-TSA65058-TSA
65058-TSA
 
9803
98039803
9803
 
SSB
SSBSSB
SSB
 
1320
13201320
1320
 
1004
10041004
1004
 

ASC

  • 1. Revere www.vpgtransducers.com 1 Model ASC Technical contact in Americas: lc.usa@vishaypg.com; Europe: lc.eur@vishaypg.com; Asia: lc.asia@vishaypg.com Document No.:11842 Revision: 23-Jul-2012 Compression Load Cell FEATURES • Capacities: 30, 40, 50, and 60T • Self-aligning, stainless steel single column • Hermetically sealed, IP66 and IP68 • Certified to OIML R60, 6000d and NTEP class IIIL, 10000 divisions • Built-in surge protection tubes (GDTs) • Current calibration output (SC) ensures easy and accurate parallel connection of multiple load cells • Optional ❍❍ Digital version available (model DSC) APPLICATIONS • Weighbridges • Silo hopper weighing DESCRIPTION The ASC is a single column, stainless steel compression load cell. This product is suitable for use in road and rail weigh bridges and process weighing applications. The welded construction and built-in surge protection ensure that this product can be used successfully in harsh environments. This load cell meets the stringent Weights and Measures requirements throughout Europe and the USA. OUTLINE DIMENSIONS in millimeters Cable specifications Cable length: 15m Excitation + Green Excitation – Black Output + White Output – Red Shield Transparent / Yellow Shield is not connected to the load cell body. Compression Load Cell Document No.:11842 Revision: 23-Jul-2012 Model ASC
  • 2. Revere www.vpgtransducers.com 2 Model ASC Technical contact in Americas: lc.usa@vishaypg.com; Europe: lc.eur@vishaypg.com; Asia: lc.asia@vishaypg.com Document No.:11842 Revision: 23-Jul-2012 Compression Load Cell SPECIFICATIONS PARAMETER VALUE UNIT Standard capacities (Emax) 30, 40, 50, 60 ton Accuracy class according to OIML R-60 NTEP IIIL Non- Approved C3 C6 Max. no. of verfication intervals 10000 3000 6000 Min. verification interval (Vmin=Emax/Y) Emax/6,000 Emax/12,000 Min. verification interval, type MR Emax/15,000 Emax/30,000 Rated output (=S) 2 mV/V Rated output tolerance 0.02 ±mV/V Zero balance 1.0 ±% FSO Combined error 0.0200 0.05000 0.0230 0.0120 ±% FSO Non-repeatability 0.0100 0.0200 0.0100 0.018 ±% FSO Minimum dead load output return 0.0250 0.0500 0.0167 0.008 ±% FSO Creep error (30 minutes) 0.0600 0.0245 0.0120 ±% FSO Creep error (20–30 minutes) 0.030 0.0200 0.0053 0.0026 ±% FSO Temperature effect on min. dead load output (0.001) 0.0250 0.0117 0.0058 ±% FSO/5°C (/°F) Temp. effect on min. dead load output, type MR 0.0047 0.0023 ±% FSO/5°C Temperature effect on sensitivity (0.0008) 0.0250 0.0088 0.0045 ±% FSO/5°C (/°F) Minimum dead load 0 % Emax Maximum safe overload 150 % Emax Ultimate overload 300 % Emax Deflection at Emax 0.5 max. mm Excitation voltage 5 to 20 V Maximum excitation voltage 25 V Input resistance 700±35 Ω Output resistance 700±35 Ω Insulation resistance ≥5000 MΩ Compensated temperature range –10 to +40 °C Operating temperature range –40 to +80 °C Storage temperature range –40 to +90 °C Element material Stainless steel 1.4542 Sealing (DIN 40.050 / EN60.529) IP66 and IP68 SC-Version (current calibration) Standard FSO—Full Scale Output SC-version: The rated output and the output resistance are balanced in such a way, that the output current is calibrated to within 0.05% of a reference value. This allows easy parallel connection of the load cells. All specifications subject to change without notice.
  • 3. Vishay Precision Group Document No.: 63999 Revision: 27-Apr-2011 www.vishaypg.com 1 Legal Disclaimer Notice Disclaimer Legal Disclaimer Notice Disclaimer Document No.: 63999 Revision: 27-Apr-2011 ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE. Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay Precision Group”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. The product specifications do not expand or otherwise modify Vishay Precision Group’s terms and conditions of purchase, including but not limited to, the warranty expressed therein. Vishay Precision Group makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase. To the maximum extent permitted by applicable law, Vishay Precision Group disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Information provided in datasheets and/or specifications may vary from actual results in different applications and performance may vary over time. Statements regarding the suitability of products for certain types of applications are based on Vishay Precision Group’s knowledge of typical requirements that are often placed on Vishay Precision Group products. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any conduct of Vishay Precision Group. The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay Precision Group products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay Precision Group for any damages arising or resulting from such use or sale. Please contact authorized Vishay Precision Group personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.