2. CONTENT
1 Machine introduction
1.1 System composition
1.2 Accessories description
1.3 Installation
1.4 Equipment parameter
2 System introduction
2.1 Working principle
2.2 Range of application
2.3 Advantage
2.4 Screen
3 Treatment
3.1 Safety check before treatment
3.2 Treatment procedure
3.3 Postoperative care and side effects
3.3 Treatment parameter
4 Notice
4.1 Installation environment
4.2 Notice before use
4.3 Notice during use
4.4 Notice after use
4.5 Operation procedure
5 Contact
3. front viewfront view
1.1 System composition
1. Machine Introduction
Handle Supporter
LED Screen
Emergency Button
Key Switch
4. Rear view
1.1 System composition
1. Machine Introduction
Handle holder
Air Switch
Foot Switch
Power Plug
Filter
Handle plug
Water Overflow
Water output
Water Input
6. 1.3 Installation
1. Machine Introduction
The system should be installed away from the hot air, and have
a certain distance with other objects.
Remove the machine parts and place the room for 30 minutes.
Step 1: Install the hand mount, as shown - to the appropriate
position.
7. 1.3 Installation
1. Machine Introduction
Step 3: Install the handle; shake the handle left and right,
hear two sounds, and install firmly.
Step 4: Install the pedal and power cord, as shown - according
to the panel to install.
8. 1.3 Installation
1. Machine Introduction
Step 5: add water - as shown in the CPC will be inserted in the
WATER OVERFLOE, from the WATER INPUT filled with pure
water; CPC has to be inserted in the WATER OVERLOW
always.
9. 1.4 Equipment parameter
1. Machine Introduction
Laser power 800W
Laser type Semiconductor laser
wavelength 808nm, 755nm , 1064nm
Spot size 12*23mm
Energy Density 10-100j/cm2 ( Continuously
adjustable )
Pulse width 20-800ms ( Continuously
adjustable )
frequency 0.5-10Hz
Refrigeration
method
Water cycle refrigeration system +
semiconductor refrigeration
Treatment head
temperature
0-4℃
Total power 2000W
Voltage AC/100-240 V, 50-60 Hz , 10A
10. 2.1 working principle
2. System Introduction
The basic principle of semiconductor laser hair removal machine is bio-
thermal effect.
The machine emits a 808nm laser that can easily be absorbed by
melanin in the hair follicle without damaging the surrounding normal
epidermis.
The energy of light is absorbed by the hair roots and hair follicles and
converted into heat, thereby increasing the temperature of the hair
follicles until the temperature is high enough, the hair follicle structure is
irreversibly damaged, the damaged hair follicles will have a natural
physiological process can not grow hair , So as to achieve the purpose
of permanent hair removal.
Modern design, stable output, short exposure, permanent effects, easy
to control, have good clinical efficacy, high safety.
2.2 Range of application
808 semiconductor laser hair removal machine for any color, any
hair color hair removal.
Contraindications:
1. A history of keloid and photosensitive disease
2 To be treated with a skin infection or a history of herpes
simplex
3. In six weeks, have used other ways of hair removal
4. Patients with coagulopathy
5. Pregnant women, epilepsy patients
6. Sun tanne, severe skin black, skin care patients with caution.
11. 2.3 Advantage
2. System Introduction
Safety: 808 nm semiconductor laser machine with stable
performance, long life: it is real-time intelligent CPU control.
Fast: 12 * 12mm spot coverage is high, fast removal of hair,
high efficiency.
Efficacy: 808nm wavelength of the laser is in the near infrared
spectrum (0.75-1.50μm), can pass through the depth of dermis
and adipose tissue, reach the different positions and depth of the
hair follicle, is a good absorption of melanin.
No pain: sapphire cooling head, cooling under the skin 0 ~ 4
. Provide cooling all of these ways, comfortable without pain.℃
Convenient: easy to use the design, easy to operate the man-
machine interface - touch screen, easy to operate.
Permanent Hair Removal: Apply to all skin colors and works
well.
12. 2.4 Screen
2. System Introduction
Machine language selection interface, you can choose
between two languages
Gender selection interface
13. 2.4 Screen
2. System Introduction
Select the option area for women to enter the treatment site
Select the male to enter the treatment site selection interface
14. 2.4 Screen
2. System Introduction
Select the female treatment site for the forehead interface
Optional range - , skin color is white to darkⅠ Ⅳ
15. 2.4 Screen
2. System Introduction
Energy: 10-100J;
Pulse Width: Pulse width, 20-800ms
Rep Rate: Frequency, 0.5-10Hz
COUNT: the current count, click on the "number" to view the
total number of the use of the handle;
RESET: clear the current count;
ON: start stop button, select the step on the foot or press the
handle button to work
BACK: return key to return to the previous operation interface.
Select the male treatment site for the armpit of the user
interface
16. 2.4 Screen
2. System Introduction
Optional range - , skin color is white to darkⅠ Ⅳ
Energy: 10-120J;
Pulse Width: Pulse width, 20-800ms
Rep Rate: Frequency, 0.5-10Hz
COUNT: The current count, click on the "number" to view the
total number of the use of the handle;
RESET: clear the current count;
ON: start stop button, select the step on the foot or press the
handle button to work
BACK: return key to return to the previous operation
interface.
Energy constraints of the pulse width and frequency, pulse
width and constrain the frequency.
For example, when the energy is 10J / cm², the minimum pulse
width is 20Ms and the maximum pulse width is 7020Ms.
The minimum frequency is 1Hz and the maximum frequency is
17. 2.4 Screen
2. System Introduction
Background entry: continuous click 10 times to set the button
18. 30r / s: water flow size;
19 :℃ water temperature size;
ID CODE: handle identification chip ID;
TOTAL COUNT: the total number of handles used;
:Second language choice
: Touch screen sound button, can turn off
2. System Introduction
2.4 Screen
19. 3. Treatment
3.1 Safety check before treatment
View the patient's treatment record.
It is recommended to select the appropriate patient
parameters based on the patient's condition and clinical
treatment guidelines.
The patient's skin is ready for work such as cleaning,
anesthesia.
All operating program status should be monitored on the
screen.
3.2 Treatment procedure
3.2.1 Preparation before treatment
When the patient's skin is dark, please protect the skin from
sunlight, 4-6 weeks before treatment to avoid the sun,
Keep the treatment site clean, dry, to shave hair, remove
grease and dirt.
3.2.2 Anesthesia
Use anesthesia or unnecessary, depending on the treatment
site (if in sensitive parts), and the patient's sensitivity to pain.
3.2.3 Treatment method
20. 3. Treatment
(1) The operator and the patient need to wear protective glasses
to prevent damage to the laser eye. Apply cold gel for the
treatment site to reduce the local epidermis temperature, the
release of pain, but also for the treatment of the head to provide
lubrication.
(2) Set the treatment parameters, first test, and then do the
normal treatment of energy density test to get the best results.
According to different clinical conditions and personal
circumstances, set the treatment parameters.
In general, 2-3 points should be tested first if each hair follicle
senses injection of pain, which means that the power density is
correct. If nothing feels low power.
(3) During the treatment, press the laser head to make the
perfect connection with the skin surface, drive the part of the
blood to reduce the oxygenated hemoglobin to absorb the laser
power.
Generally, proper overlap should be maintained. Because the
overlap will damage the skin, so the rate should be controlled
below 10 ‰.
Ultra-wide interval pulse will weaken the therapeutic effect.
(4) In the course of treatment, in order to ensure safety and
effectiveness, sapphire treatment head should always clean up.
3.2 Treatment procedure
21. 3. Treatment
(5) Different parts of the hair have different growth cycle, so the
treatment interval changes accordingly.
Like the hair on the head, the relative quiescence is short, (about
12-16 weeks). Treatment interval of 30 days, so that the hair of
the development period.
In the body and limbs of the hair, the rest of the time 12-24
weeks; treatment interval is 60 days.
In general, the best time is when the hair begins to grow.
(6) With some chlortetracycline ointment, erythromycin and other
antibiotic ointment, the treatment in the treatment part, or gently
hand wash the surface to avoid local infection.
Use sunscreen (SPF> 15: PA + + +) to avoid direct sunlight and
prevent pigmentation.
3.2 Treatment procedure
3.3 Postoperative care and side effects
(1) superficial lesions after treatment
(2) pigmentation or pigment loss may occur.
But this complication is temporary; it will recover naturally after a
few months.
(3) treatment will be a slight pain, but can be accepted, you can
also use local anesthetic cream, under normal circumstances do
not use
(4) Allergic purpura (HSP) may occur 1-3 days after treatment.
(5) mild redness will appear in the treatment site, but usually will
disappear after a few hours.
22. 3. Treatment
3.4 Treatment Parameter
The following treatment parameters for reference only, the
customer needs to be adjusted in the appropriate treatment.
1. Point treatment:
Set the machine energy to high energy, the frequency should
be set to low frequency 1Hz. The machine has default
parameters, the doctor can adjust according to the
situation, but please do not adjust the frequency, only
adjust the energy; in this mode, adjust the energy pulse
width will automatically adjust.
Male Skin Type White Yellow Brown Dark
Lipstones Energy 20 18 17 15
Pulse Width 92 86 86 80
Frequency 1 1 1 1
Underarm Energy 24 21 20 18
Pulse Width 100 88 95 86
Frequency 1 1 1 1
Forehead Energy 15 13 12 10
Pulse Width 80 70 68 48
Frequency 1 1 1 1
23. 3. Treatment
3.4 Treatment Parameter
Male Skin Type White Yellow Brown Dark
Bikini Energy 17 15 14 13
Pulse Width 76 80 70 70
Frequency 1 1 1 1
Thigh Energy 25 22 21 20
Pulse Width 100 95 90 90
Frequency 1 1 1 1
Leg Energy 20 18 17 15
Pulse Width 80 86 90 80
Frequency 1 1 1 1
Female Skin Type White Yellow Brown Dark
Lipstones Energy 22 20 18 16
Pulse Width 110 110 95 90
Frequency 1 1 1 1
Underarm Energy 25 23 22 20
Pulse Width 110 100 90 90
Frequency 1 1 1 1
Forehead Energy 16 15 13 10
Pulse Width 85 80 70 48
Frequency 1 1 1 1
24. 3. Treatment
3.4 Treatment Parameter
Female Skin Type White Yellow Brown Dark
Bikini Energy 18 16 15 13
Pulse Width 80 90 80 70
Frequency 1 1 1 1
Thigh Energy 25 23 22 20
Pulse Width 100 100 90 90
Frequency 1 1 1 1
Leg Energy 22 20 18 16
Pulse Width 95 90 90 85
Frequency 1 1 1 1
2. Slide therapy
Set the machine energy to low energy, the frequency should
be set to high frequency 8Hz.
During the treatment of doctors do not need to adjust the
parameters, they only need to choose according to the
patient's choice of treatment time and the number of treatment.
25. 3. Treatment
3.4 Treatment Parameter
Male/Female Skin Type White Yellow Brown Dark
Parameter Energy: 5 Pulse Width: 80ms Frequency : 5cm2
Lipstones Speed 3cm/s 3cm/s 5cm/s 5cm/s
Treatment
Time
0.5min 0.5min 1min 1min
Underarm Speed 3cm/s 3cm/s 5cm/s 5cm/s
Treatment
Time
1min 1min 1.5min 2min
Forehead Speed 1cm/s 1cm/s 2cm/s 2cm/s
Treatment
Time
0.5min 0.5min 0.5min 0.5min
Bikini Speed 1cm/s 1cm/s 2cm/s 2cm/s
Treatment
Time
0.5min 0.5min 0.5min 0.5min
Thigh Speed 3cm/s 3cm/s 5cm/s 5cm/s
Treatment
Time
1min 1min 1.5min 1.5min
Leg Speed 3cm/s 3cm/s 5cm/s 5cm/s
Treatment
Time
1min 1min 1.5min 1.5min
26. 4. Notice
4.1 Installation Environment
Working environment:
a) Ambient temperature: at room temperature around 25 for℃
treatment, room temperature can not be too low or too high.
b) Relative humidity: ≤ 80%
c) atmospheric pressure range: 860hPa ~ 1060hPa;
d) Power: 110 ~ 220V + 10%, 50 / 60Hz.
Transport and storage conditions:
a) Temperature range: -20 ~ 60 ℃
b) relative density range: ≤ 100%;
c) Atmospheric pressure range: 500hPa ~ 1060hPa.
4.2 Notice before use
[1] Before starting, the tank must be filled with water and must be
inserted into the handle.
[2] Check the buttons to make sure they work properly.
[3] Ensure that the room temperature is higher than 16 ° C.
[4] When using the machine, the CPC will be inserted in the
exhaust port, push bubbles out.
[5] Each time you change the water from OVERFLOW a small
amount of water, there is water out.
27. 4. Notice
4.3 Notice during use
[1] Before hair removal, kick off the hair, because the hair will absorb the laser
energy and produce a strong heat, resulting in local skin thermal damage, and
laser treatment head damage.
[2] Start debugging from low-power energy to prevent burns and find the right
therapeutic energy to reach the patient's treatment level.
[3] Make sure the laser output is in contact with the skin.
[4] During treatment, be sure to keep sapphire clean. Any substance that
absorbs laser energy on the treatment head increases the temperature after
absorbing the laser, causing damage to the epidermis and pain.
[5] If the water temperature below 16 ℃, there will be water temperature
protection, the machine starts running for 10 minutes to be higher than 16 ℃
water temperature;
if the machine work continuously, the water temperature is higher than 36 ℃,
there will be water temperature protection, Machine to be less than 36 when℃
the water temperature
[6] When the Rep Rate is set to 0.5Hz, each time the light interval of 2s.
[7] Continue to press the button , the handle have voice only in the first light; if
you want the handle every time having voice, press the button time needs more
than 1s interval.
4.4 Notice after use
[1] Can work in the handle state shutdown, ready to state.
[2] After each treatment, use alcohol to clean the handle.
[3] When you take out the handle, the machine must be closed.
[4] Replace the water once a month, must use pure water.
[5] 3-6 months to replace the filter.
28. 4. Notice
[1] Remove the treatment area excess hair (stay 1-2mm)
[2] Clean the treatment area and do skin disinfection
(According to demands to apply anesthetic cream. After use machine , put
anesthetic cream to avoid burn)
[3] At the treatment area smear cool gel about 2mm thickness
[4] Adjust the treatment parameters:
According to the system to adjust the parameters in the system, the general
parameter adjustment to follow the principle:
The customer can tolerate the maximum value of treatment (in the case of no
burns, higher energy better result )
Generally if the customer can tolerate energy, it will not burn the skin,
remember not in the same part to do treatment twice in one time, because the
energy will gather easily scalded skin, when you are skilled in the operation of
the machine, even you put anesthesia cream you also know very clearly which
Parameters will not burn skin, but the effect is the best.
[5] Wear protective goggles and goggles for treatment, if some area not good
treat, you can treat again, but must not be in the same place for a continuous
light until the hair follicles can be slightly red hair.
[6] After treatment, clean the skin after the application of anti-inflammatory
ointment, avoid moisture within a day, avoid the sun within a week.
Clean the treatment area, you can wipe with alcohol every day to avoid the
occurrence of folliculitis
[7] Continue to treatment.
4.5 Operation procedure
29. After-sale Service
Our company solemnly promises:
We provide two-year free after-sale (Not including consumable –
heads, and man-power damage )service since the date of signing a
contract. However, damages caused by man and consumables are
not included. If the equipment fails during the warranty time, our
professionals will provide a door to door service. This equipment will
have a lifelong maintenance. While if some parts need to be
changed, you need to pay.