SlideShare a Scribd company logo
1 of 26
Download to read offline
E-light+Laser Multifuctional Beauty
Equipment Yinhe-King USER MANUAL
Please read this manual carefully
before operating this machine and
Retain it for future reference.
For your safety
1.Before open the machine,you must fill the water to this machine until the water
automatically come out of overflow,means the water is full of water tank. or it will
easily make it broken.
1.Keep any reflecting things out of the operating room,such as mirror,watch,jewellery...
2.Operator and the patient must wear the professional protective glasses and googles.
3.Any intense pulsed light without correct using can injure the body. In the course of
working,the device will produce high pressure.So every operator should keep warning,
operating according to this introduction.
4.Patient:Well-trained operator and appropriate disposal treatment room is very
necessary and important.Moreover,the patient should also know the treatment theory and
wear the professional protective eyepatch, protecting eyes from burning.
5.Operator:Durng the treatment, it’s possible to touch the intense pulsed light,so it’s
necessary to wear the professional protective glasses.
6.Treatment room: the room must clear mark “using intense pulsed light”
7.Except the authorized mechanic, anyone have no right to examine and repair the
machine,especially the inside of device that including electrical source, cooling
system,optical organs and treatment head.Notice the dangerous high pressure inside.
8.Make sure whether it’s accordant to your resident voltage or not.
9.Maintenance must after turning off the device and drawing out the electrical source
line.Or it’s most possible to injure people and damage the equipment.
10.Keep the filter and the probe clean.
11.Stop turning on when finding slack from treatment head. If turning on, close right now.
12.Over light energy could burn skin, that results in atrophy or pigment deposit.
13.Do not directly see the intensed pulsed light during treatment,even wearing the
protective glasses and eyepatch.
14.Do not allow to point the treatment handpiece to the air.Generally,hang it in the bracket
of the machine.
15.High pressure inside the equipment. It’s possible to deposit electricity in some parts
even after switching off. So it’s not allowed to open equipment beyond the authorized
mechanics.
16.When maintaining, please close power, cover board, and observe in person.
17.Total weight is a little heavy, so please take care when moving.
18.The temperature will raise after absorbing light energy, so please take actions to
reduce the flammable risk on treatment parts or around area.
19.Do not use ethanol, acetone or other flammable things on skin before treatment.If
necessary,please use soap or water.
20.When listerizing the treatment head or other parts in ethanol, please wait till dry
Who is forbidden?
1.People who are allergic to light.
2.Pregnant women,Diabetes suffers,cardiac patients,people with Hypertension,Epilepsy
and skin cancer.
3.People with cardiac pacemaker and defibrillator.
4.People whose treatment parts are damaged.
5.People are just back from the beach.The skin is very weak after the exposure in the sun
in this time.
6.People have taken some photosensitive food or drug recently.
Important Information
This user's guide contains important information on the use and operation of
this machine.Please read all the information carefully for optimal performance
and to prevent any damage to or misuse of the machine.Any changes or
modifications not expressly approved in this user's guide could void your
warranty for this equipment.
Overview
 Accessories
Check to make sure you have all parts shown below.
Fileter E-light handle Key
Remarks:
1.Power line:to connect machine
2.Foot switch:for operation
3.Treatment handpiece:for treatment
4.Trips:part of the treatment head
5.Protective glasses:for operator; Protective goggles:for patients
6.Keys:main switch to open and close the machine
7.Watering bottle:for filling water to the machine
Part of the machine
Front of the Machine
Picture one
Pay attention:
1.Place the device on the level ground.(If there’s water on the surface of the device,please
wait till dry then input water to test).Keep 22℃-28℃ temperature and the humidity not
more than 20% in the treatment room.
a. If there’s something hurt suddenly happened,press down the Red button(Emergency
switch) at once.If you do not move the machine to long distance place,do not
press down the emergency button.When you finish the treatment,just close the key
switch and pull out the power line rear of this machine.
3.Gently turn the Emergency switch( red button) towards right before opening key
switch.Usually the button will bounce at once,If not,you should continue to revolving the
red button until it’s absolutely bounce.
Laser
handle
Display
screen
Key switch
Emergency button
E-light handle
1.1.Laser Part
Principle of Treatment
Laser uses the high energy laser beams emitted by a sapphire to effectively smash
pigments inside pathologically changed tissues, i.e. light explosion and
photo-thermolysis principle: the high energy produced by the laser is emitted instantly, so
that laser beams with a fixed wavelength can penetrate the epidermis into pathologically
changed tissues within a certain working time (12ns), and quickly smash corresponding
pigments, which expand rapidly and explode instantly due to extreme heat. A part of the
pigment cluster (on the surface of the epidermis) pops out of the body, a part of the
pigment cluster (inside basal tissues) are smashed into fine particles that can be
devoured by macrophages, while some dirt and cuticle remaining on skin epidermis are
smashed and decomposed by the principle of active carbon explosion, then devoured
and digested by macrophages, and finally expelled out of the body via the circulation of
the human lymphatic system, thus the pigments in the pathologically changed tissues will
fade out and disappear gradually. And yet no damage will be done to the normal skin
tissues in the vicinity since they do not absorb laser beams with a certain wavelength.
b. Applications:
1) Removalof eyebrow line, eye line, lip line...etc
2) Removalof tattoo(red, blue, black...etc)
3) Clearance speckle, black naevus, fleck, age spots...etc
4) Removal of vascular lesion and spider vessel...etc
c. Feature and Benefits:
1) Innovative in laser technology, strict in technical detection, precise in manufacture.
2) Special designed cooling system ensures constantly working.
3) New fashionable outlook design.
4) Portable and aseismatic, convenient for transportation.
5) No injury to normal tissue.
6) Remove pigmentation without side effects or scar.
7) Accurate infrared indication light makes the spot position more accurately and
increases the utilization of light point
A Operating Instructions
When the instrument is turned on, the welcome screen (Figure 1) will show up. Press any
button to enter into the treatment screen:
Screen Display:
After having entered into the treatment screen, the operator can press the Frequency
button and Voltage button to adjust working frequency and working voltage. Press the first
button to the left (Trigger). When the xenon lamp is successfully turned on, the button
status indication will show an “inverse effect”. Press the Working button to enable working,
an “OK” symbol will show up in the status indication zone. Then, the operator can start
working by stepping on the foot pedal. During working, a pulse count is added whenever a
pulse is released. To turn off the instrument, first press the Working button to stop working,
then press the Trigger button to turn off the xenon light, and lastly turn off the power switch.
During working, the operator can directly press the Trigger button to exit pre-ignition.
When the foot pedal is stepped on, all the buttons will not work.
Introduction to Operation for Treating Various Defects
Removing Tattooed Eyebrow
1. Removing Monochromatic Blue or Black Tattooed Eyebrow
During operation, the patient should not open his/her eyes. The operator selects the
required laser energy according to the depth of the tattooed eyebrow (adjust laser beams
to a suitable energy level), and holds the laser gun by hand and slowly moves the gun
close to the area to be treated from the normal skin around the area, so as to help the
patient adapt psychologically. Then, the operator can set the laser beam emission rate to
5Hz, and perform the treatment when the gunpoint is 1-2 fingers width away from the area
to be treated. It is OK to start treating from the tail of the eyebrow or the head of the
eyebrow. If there is a sign of color recovery within 5-10 minutes after treatment, second
treatment can be performed. At this time, the energy level should be 20-40 units higher
than that used for the first treatment. The gunpoint should be 1-2 fingers width away from
the area to be treated, so as to further smash pigments and boost absorption by the body.
Check the result one and a half month later. For a patient who has some remaining
pigments, second treatment can be performed. (If the energy cannot be absorbed due to
faded color, active carbon can be applied for the treatment in order to facilitate energy
absorption.)
2. Removing Makeup Tattooed Eyebrow (it will take 2-3 times of treatment to
completely remove makeup tattooed eyebrow)
The operator can set the laser beam emission rate to 3 Hz. First use a 1064nm light head
to perform the treatment with the gunpoint placed at a distance of 2-3 fingers width away
from the area to be treated. Then use a 532nm light head to perform the treatment. Since
coffee (brown) color is a mixed/harmonizing color, treatment usually needs to be
performed more than two times, and the interval of treatment is 45-90 days. When
performing treatment for the second time, the operator should select a light head
according to the remaining color. (If the energy cannot be absorbed due to faded color,
active carbon can be applied for the treatment in order to facilitate energy absorption.)
3. Removing Tattooed Eye Lines
The operator can set the laser beam emission rate to 3 Hz. Adjust the laser energy to the
lowest level (initial laser beam emission value), and place the gunpoint at a distance of 1-2
fingers width away from the area to be treated – it will be just right when the light spot can
be seen by eye! The operator must use a piece of thick medical gauze or an eyelid patch
to well protect the eyes. First, the operator should remove the lower tattooed eye line –
ask patient to tightly close his/her eyes and “look” upward at the same time. The operator
uses his/her forefinger to hold the gauze and push the upper eyelid upward, uses his/her
middle finger to open the lower eyelid to expose the lower eye line and uses 5Hz laser
beams to perform the treatment. After this, the operator can remove the upper tattooed
eye line – ask the patient to tightly close his/her eyes and “look” downward at the same
time, while the operator uses his/her middle finger to hold the gauze and press the eyelid
downward, uses his/her forefinger to push the eyelid upward to expose the upper tattooed
eye line, and uses 5Hz laser beams to perform the treatment.
4. Removing Tattooed Lip Lines
The operator can set the laser beam emission rate to 5Hz, and place the gunpoint at a
distance of 3-4 fingers width away from the area to be treated. When removing black,
coffee, crimson or brown lip lines, the operator should first use a 1064nm light head to
perform the treatment, and then repeat with a 532nm light head. When removing light red,
red, light coffee or light brown eye lines, the operators should use a 532nm light head to
perform the treatment.
Attention: Treatment must be performed on all tattooed lip lines within half a year after
tattooing. Otherwise, the operation will fail. The course of treatment is 45-60 days.
Periodical treatment should be performed until lip line tattoo is clear.
5. Removing Tattoo, Birthmark, Venus of Ota and Nevus Spilus
The operator can set the laser beam emission rate to 3-5Hz, place the gunpoint at a
distance of 3-4 fingers width away from the area to be treated, and use the energy as
close to the focal high energy as possible to perform the treatment. The result will be the
best if bleeding spots show up. For removing common dark blue marks, the operator
should select a 1064nm light head to perform the treatment. For removing red or coffee
marks, the operator should select a 532nm light head to perform the treatment. The
course of treatment is 45-90 days. Periodical treatment should be performed until the
mark is cleared (if the energy cannot be absorbed due to faded color, active carbon can
be applied for the treatment in order to facilitate energy absorption).
For treating a birthmark and nevus spilus, we recommend the use of a 1064nm light head.
For treating a birthmark, the treatment must be performed until bleeding shows up. For
treating a nevus of spilus, the result will be the best if bleeding spots show up. If a 1064nm
light head is ineffective for treating a dark color birthmark, a 532nm light head can be used
to perform the treatment. The course of treatment is 45-90 days. Periodical treatment
should be performed until the mark is cleared.
7.Skin Rejuvenation
8. Reaction During Operation
Due to the instant radiation of high energy laser beams, the pigment cluster of
pathologically changed tissues quickly decomposes into fine particles that can be
devoured by macrophages in the human body; some pigments on the epidermis instantly
pop out of the body, while other pigments inside deep layer tissues are evenly distributed
to the epidermis. Therefore, the color will be recovered somewhat within a short period of
time after operation. When tissues with a dark color or deep lines are treated, local signs
of redness, blain or even bleeding spots may occur due to the intense absorption of laser
energy by melanin. These are normal reactions of the tissues. The degree of local
inflammation varies with different patients. When inflammation is alleviated, the patient
may feel itching or tissue hardening when touching the tissue. In general, all these will
disappear naturally within 3-7 days after operation. They may last for 1-3 months for some
patients with poor physical conditions.
9. Caring after Operation
Within 1-3 days after operation, the patient should never apply make up on the eyebrow,
washing or touching the bleeding area, lest it might cause infection. The patient should
pay attention to sunscreening to prevent sunlight from causing hyper-pigmentation. For a
patient having serious bleeding or swelling, he/she can take some antibiotic medicines
such as acetylspiramycin according to the instruction of his/her doctor. In 72 hours after
operation, the patient should coat the treated area with recover/repairing cream to
facilitate healing. The patient should avoid direct UV radiation. Taking vitamin C orally can
alleviate pigment return. Before the crust peels off, the treated area should not be in
contact with water or be rubbed. Within one week after operation, the patient should give
up spicy food, seafood, irritating food, cigarette and wine, and never have dark color food
such as coffee and cola. The patient should let the crust peel off naturally. Within one
week after pigment treatment the patient should not have sex in order to prevent pigment
return. Pigment fading away is a slow process, which is usually one and a half month or so.
If a patient needs to be treated again in order to achieve the best result, the interval of
treatment should be about 2 months. The treatment for some defects may need to be
performed for multiple times according to the nature of pathological change, the
shade/depth of pigments, and different areas.
 Installation E-Light Part
E-Light Beauty System
Theory
It combines three advanced technologies: Bipolar Radio Frequency + IPL +Skin
Contact Cooling.
When the three are united in one treatment, wonderful treatment experience and
result can be expected. The energy of Radio Frequency can reach the middle and
deep layer of the skin and heat up tissue, thus, lower energy is applied during the
IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased
significantly and better result can be expected. In addition, cooling system involved
in E-light can also ease the uncomfortable feeling.
The absorbing of the energy of radio frequency is not concerned with melanin. So,
the E-Light treatment can get good result on the soft or thin hair so as to decrease
the risk caused by traditional IPL treatment.
Application Range
1.Remove undesired hair permanently from various areas of the body for all
kinds of hair color;
2.Remove specklesage spotsun-induced freckles from various types of skin;
3.Remove facial vascular lesions;
4.Skin rejuvenating and lessen deep wrinkles;
5.Tighten skin and remove acne.
6.Skin whitening.
Advantage
1.Remarkable effects on fuscous spot and live spot
2.Great effect on unwanted hair removal, both thick black hair and tiny hair, and
comfortable during the treatment
3.Avoid burn, pigment mark and blister during former IPL treatment
4.Wide range of treatment, great effect, and with high safety factor
5.Large color touch screen, comfortable and elegant
6.Breakthrough based on traditional IPL technology
 Operation Steps
1.There's five modes in all,take skin rejuvenation as an example:
2.Start to operate
2.1 Choose filter for Skin rejuvenation 530nm,set up it to the treatment head
2.2Choose the treatment mode,touch the Key [skin rejuvenation]
2.3 Begin to operate after touch the [Standby] first,at this time, [Ready] will show you.
Pay attention:the treatment head must close to the surface of skin,gently press down the
green or yellow button of the treatment head.Of course you could also use foot touch to
operate.in this case,you do not need to press down two buttons of the head.Just steps on
the E-light foot switch.
If you finish this operation:
Step one:you just need to touch this [Ready] key,then back to Pic.3.
Step two:turn off the key switch ,you need to turn the key to left.
According to the above statement, other treatment modes can be operated like it.
The technical parameters of operation
*640nm,690nm--Hair Removal
*530nm--Pigmentation Therapy,Spots Removal,Skin Rejuvenation
*580nm,590nm--Vascular Therapy
*480nm,430nm--Acne Treatment
Pay attention:the filters above are optional
Pay Attention:
The parameters above are just as your reference,you'd better start a little smaller energy
the first operation,then ask the patients if they feel like a slight tingling or a pinch similar to
the snap of a rubber band.IF yes,continue to treat,or you try to increase the parameters
gradually two by two,like 10/12/14...For first treatment,we suggest IPL energy start from
6.You'd better repeat to shot the same treatment area.
Hair Removal
Hair Removal
a. one course in all,every months as one treatment,4-6 treatments in all.Usually,very
significant effect will show you after 2-3 treatments. For thick hairs,it needs 3
treatments.For soft and thin hair,it needs 5 treatments.Treatment time:For two arms:in 1.5
Pre-operation Clean skin Apply even gel on skin
hours;For two legs:in 1.5 hours;For armpit hairs:in 30 minutes.
d. Effect of cooling gel: cooling and light transporting
e. Usage: spread the cooling gel on the treatment area before treatment, about 3mm
thickness; 20 minutes after the treatment, scrape the cooling gel, or cooling with ice for
10-20 minutes
f. Operating sequence: shave away unwanted hair or shear the unwanted hair, 1-2mm to
the hair root first,then Clean skin and spread cooling gel on the treatment area; after the
treatment, make an ice cooling treatment.
Skin Rejuvenation(530nm)
Skin Rejuvenation
a. one course in all,every 3 weeks one treatment,4-6 treatments in all.Usually,very
significant effect will show you after 2-3 treatments.For face treatment,it needs about 30
minutes.
b.Pre-operation:deeply skin cleaning,remove acne,blackhead
c. Feelings in the treatment: Swollen feelings inside skin.A little inflamed feelings on skin
after the treatment.
d. Effect of cooling gel: cooling and light transporting
e. Usage: spread the cooling gel on the treatment area before treatment, about 3mm
thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for
10-20 minutes
f. Operating sequence: Clean skin and spread cooling gel on the treatment area; after
the treatment, make an ice cooling treatment.
Acne Treatment(480nm)
Acne Treatment
a. 1-2 course.(very serious skin problems,it needs 2 course),3 weeks one treatment.4-6
treatments in all,very significant effects show after 2-3 treatments.
b. Pre-operation:deeply clean skin.
c. Feelings in the treatment: very Swollen feelings inside skin.A little painful inflamed
feelings on skin after the treatment.
d. Effect of cooling gel: cooling and light transporting
e. Usage: spread the cooling gel on the treatment area before treatment, about 3mm
thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for
10-20 minutes
f. Operating sequence: Clean skin and spread cooling gel on the treatment area; after
the treatment, make an ice cooling treatment.
Vascular Therapy(530nm)
Vascular Therapy
a. 4-6 treatments as one course,3 weeks apart,one or two course in all.Very obvious
effects will show you after 2-3 treatments.
b. Feelings in the treatment: Swollen feelings inside skin.A little inflamed feelings on skin
after the treatment.
c. Effect of cooling gel: cooling and light transporting
d. Usage: spread the cooling gel on the treatment area before treatment, about 3mm
thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for
10-20 minutes
e. Operating sequence: Clean skin and spread cooling gel on the treatment area; after the
treatment, make an ice cooling treatment.
Pigmentation Therapy(530nm)
Pigmentation Therapy
a. 1-2 course(2 course is for very serious skin problems,like serious chloasma),3-4 weeks
one treatment,4-6 treatments in all.
b.Treatment symptoms:the freckles become darker after one treatment,the treatment area
will be red,the freckles will gradually be light and drop off.
c.Feelings in the treatment:some pain feelings like needle pricking. In one week after the
treatment, spots will be darker first.Usually after one cycle treatment,the perfect results
will show you.ffect of cooling gel: cooling and light transporting
e.Usage: spread the cooling gel on the treatment area before treatment, about 3mm
thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for
10-20 minutes
f.Operating sequence: Clean skin and spread cooling gel on the treatment area; after the
treatment, make an ice cooling treatment.
Maintenance
1.No stress on the Screen, prevent from breaking up
2.Keep the filters and probe clean,do not let the cooling gel enter into probe. We suggest
you slightly clean the filters' wafer after each treatment with soft and clean paper towel,if
it's very dirty on its wafer,please Dip the paper towel in a little dehydrated alcohol.then
clean it.just as follows:
1.Filters and Treatment head
 Operation
1.Normal watering:Screw off the little screw cap from overflow,then Input water(pure
water or distilled water):Connect the watering bottle and inlet well,when there’s water
automatically spill from the overflow,means the water is full of the water tank,at this time
you have to keep the outlet closed.
1.1 Change the water inside of the machine every 10-15 days if you use the machine very
often.
1.2 When changing water,just screw off the screw of outlet.(You’d better put a water
container under it)
1.3 Our Apparatus is equipped with powerful cooling system,after five minute's
working,you have to filling water again till there's water automatically spill from the spilt
hole.For this new machine,if the probe is very hot in the beginning 10 seconds
working,please do not hesitate to close it right now.Then shaking this treatment head 3
times over your head,in this case,the water of the head will flow back into water tank.If the
probe is still hot,you can just repeat this action. Please never power on the equipment if
you do not fill water in it.
2.Insert the relevant filter to the E-light treatment handle, then turn on the key switch. After
that, please observe the water circulation inside the device. Normally, you will hear the
sound of water flow. The probe runs cold in 1-2 minutes, at this time, you have to turn on
the cooling switch at the rear of this machine, just press it. If the treatment head is too
cooling, then please turn off it for a while.
3. Starting up
3.1 Press any point on the screen ,the screen will show you as follows:
3.2 Press to come into the following setting screen:
press return back to the picture 2.
There are six modes:hair removal, skin rejuvenation ,pigmentation therapy, vascular
therapy, acne therapy, wrinkle removal. Choose any one that you want to do, let us take
hair removal for example.
Pre-operation
1.clean skin, record detail skin conditions.
2.remover the hair of the treatment area.
3.spread cooling gel on the treatment area, about 3-5mm.
2.Start to operate
2.1 Choose filter for hair removal 640nm,set up it to the treatment head
2.2Choose the treatment mode,touch the Key [hair removal]
2.3Adjust the parameters according to the feeling of patient
saving buttons, after adjusting the parameters ,touch
any saving button,this parameters can be saved in it, then you can receive the
parameters by touch the saving button.
press to increase or decrease energy of IPL and RF.
adjust cooling lever.
When you adjust the pulse width,pulse delay and frequency,you should touch the button
needing adjust ,then touch the
2.4 Begin to operate after touch the first,at this time, then will be
lighted
IPL energy
RF energy
Counter
Pulse width
Pulse delay
Frequency
Pay attention:the treatment head must close to the surface of skin,gently press down the
green or yellow button of the treatment head.Of course you could also use foot touch to
operate.in this case,you do not need to press down two buttons of the head.Just steps on
the E-light foot switch.
2.5If you finish this operation:
Step one:you just need to touch this key,then will be off.
Step two: touch to turn back to picture 2.
Step three: turn off the key switch , you need to turn the key to left.
According to the above statement, other treatment modes can be operated like it.
Warns after treatment and Maintenance
 Warnings after treatment
1.Pay attention:In one month after treatment,the patient should use sunscreen
SPF15,when going out,you'd better take an umbrella and wearing a hat in case of
sunburn.If your skin expose in the sun,it will increase the regeneration rate of
melanoma,directly result in excessive pigmentation.
2.You should often use moisture mask to supply water to your skin.Keep your skin retain
water.You'd better use a mask before treatment.
3.Do not make up immediately after treatment.You'd better use the pure biological skin
care products,not chemical products and the silty cosmetics.If there's flare on treatment
area,a doctor should be notified immediately and stop make-up.Take some VitC or VitE.
4.Treatment course:6-8 times as one course,2-3 course in all.The next treatment should
be carried out after 3 weeks .After one course treatment,the problems such as age
spots,spots,ect will be solved,the skin becomes shiny and flexible.
5.As physical differences in personal,individual customers may be temporary
discomfort,small blisters,pigmentations,flare,in this case,we suggest you use ice pack for
30 minutes,you can make up 5 days later after treatment.
 Maintenance
1.No stress on the Screen, prevent from breaking up
2.Keep the filters and probe clean,do not let the cooling gel enter into probe.
3.The handle is fragile, please take care when pick up and dropt it in the
bracket.
4.Every 15 days to change the water. After changing water, please make sure water
circulate normally before usage. If the probe continuing be in high temperature after
continuing working too long.you could change half of water from the machine.In this
case,the temperature will reduce at once.
5.To keep the powerful energy,we suggest you change the water after 3000 shots.
6.Please check the surface of treatment head if there's attachement object after
treatment,if so,please lightly clean it with lens paper or absolute alcohol.
 Malfunction and solutions
1.No power supply:
a.Check up whether there is power sup
b.Check up whether the power line is connected well.
c.Check up the fuse, which could be pulled out at the bottom of hole for power plug.
d.Check up if you open the key switch and emergency switch.
Solution:
a.connect well the power line
b.change the fuse;
c.open the key switch and release the emergency switch button
2.Non-Refrigeration after opening the machine:
a.cooling electric source is broken
b.Semiconductor is broken
c.there's air in the treatment head,non well water circulation
Solution:
Contact us directly
3.Treatment Head leakage:
a.the srews of the head loose
b.the water pipe inner of the head has dropped down
c.lamp or crystal of the head is broken
Solution:
Contact us
4.The Treament head can't light on:
a.The head is broken
b.The controller is broken
c.The Power line is broken
Solution:
Contact us
No Flashing
a.Do not control well of the switch on the treatment head
b.Make the wrong operation
c.The controller is broken
d.The power line is broken
e.Need to change a new treatment head.
Solution:
Contact us

More Related Content

What's hot

Rex karaⅱ eng
Rex karaⅱ engRex karaⅱ eng
Rex karaⅱ eng
jumiss
 
Autel Powerscan PS100 User Manual
Autel Powerscan PS100 User ManualAutel Powerscan PS100 User Manual
Autel Powerscan PS100 User Manual
obddeal
 

What's hot (10)

Gurin Portable Ultrasonic Massager
Gurin Portable Ultrasonic MassagerGurin Portable Ultrasonic Massager
Gurin Portable Ultrasonic Massager
 
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable batteryPm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
Pm-120 tens unit electronic pulse massager with 6 mode and rechargeable battery
 
Rex karaⅱ eng
Rex karaⅱ engRex karaⅱ eng
Rex karaⅱ eng
 
Ebeauty 808nm Diode Laser Machine user manual
Ebeauty 808nm Diode Laser Machine user manualEbeauty 808nm Diode Laser Machine user manual
Ebeauty 808nm Diode Laser Machine user manual
 
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable BatteryPM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
PM-180 Tens Unit Electronic Pulse Massager, Backlit LCD and Rechargeable Battery
 
Zmpcrm077000.12 User's manual
Zmpcrm077000.12 User's  manualZmpcrm077000.12 User's  manual
Zmpcrm077000.12 User's manual
 
ZMPCRM077000.12 User's Manual
ZMPCRM077000.12 User's ManualZMPCRM077000.12 User's Manual
ZMPCRM077000.12 User's Manual
 
ZMPCRM077000.12 User's manual
ZMPCRM077000.12 User's  manualZMPCRM077000.12 User's  manual
ZMPCRM077000.12 User's manual
 
Autel Powerscan PS100 User Manual
Autel Powerscan PS100 User ManualAutel Powerscan PS100 User Manual
Autel Powerscan PS100 User Manual
 
John deere te gator utility vehicle service repair manual
John deere te gator utility vehicle service repair manualJohn deere te gator utility vehicle service repair manual
John deere te gator utility vehicle service repair manual
 

Viewers also liked

Corporate Profile
Corporate ProfileCorporate Profile
Duffy, Daniel J. Current Resume
Duffy, Daniel J. Current ResumeDuffy, Daniel J. Current Resume
Duffy, Daniel J. Current Resume
danduffy49
 
Web quest
Web questWeb quest
Web quest
LUYEDIC
 
News Jun 21-27
News Jun 21-27News Jun 21-27
News Jun 21-27
nuthorn
 
News June 8-14
News June 8-14 News June 8-14
News June 8-14
nuthorn
 
Web quest
Web questWeb quest
Web quest
LUYEDIC
 

Viewers also liked (18)

Corporate Profile
Corporate ProfileCorporate Profile
Corporate Profile
 
La famiglia lucchetto
La famiglia lucchettoLa famiglia lucchetto
La famiglia lucchetto
 
Test
TestTest
Test
 
Duffy, Daniel J. Current Resume
Duffy, Daniel J. Current ResumeDuffy, Daniel J. Current Resume
Duffy, Daniel J. Current Resume
 
Ict revolution at fcsit
Ict revolution at fcsit Ict revolution at fcsit
Ict revolution at fcsit
 
Chuc nang phan mem quan ly khach hang crm
Chuc nang phan mem quan ly khach hang crmChuc nang phan mem quan ly khach hang crm
Chuc nang phan mem quan ly khach hang crm
 
Luck
LuckLuck
Luck
 
Web quest
Web questWeb quest
Web quest
 
Hizb 54
Hizb 54Hizb 54
Hizb 54
 
News Jun 21-27
News Jun 21-27News Jun 21-27
News Jun 21-27
 
Diapositivas
DiapositivasDiapositivas
Diapositivas
 
Women trends
Women trendsWomen trends
Women trends
 
News June 8-14
News June 8-14 News June 8-14
News June 8-14
 
Smart DP Transmitter 100SDP
Smart DP Transmitter 100SDPSmart DP Transmitter 100SDP
Smart DP Transmitter 100SDP
 
Hizb 30
Hizb 30Hizb 30
Hizb 30
 
Hizb 21
Hizb 21Hizb 21
Hizb 21
 
Ski
SkiSki
Ski
 
Web quest
Web questWeb quest
Web quest
 

Similar to Yinhe King User Manual

Rex karaⅱ eng
Rex karaⅱ engRex karaⅱ eng
Rex karaⅱ eng
jumiss
 
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIASV5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
MiNeyi1
 
Manual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizadoManual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizado
JorgeCobo11
 
Portable 808-Brochure
Portable 808-BrochurePortable 808-Brochure
Portable 808-Brochure
Beibei Wang
 
Jay 1 neutral user manuel
Jay 1 neutral user manuelJay 1 neutral user manuel
Jay 1 neutral user manuel
Jeroxxx
 
Forimi SHR Machine FMS-1
Forimi SHR Machine FMS-1Forimi SHR Machine FMS-1
Forimi SHR Machine FMS-1
Beibei Wang
 

Similar to Yinhe King User Manual (20)

Yinhe V18 User Manual
Yinhe V18 User ManualYinhe V18 User Manual
Yinhe V18 User Manual
 
Rex karaⅱ eng
Rex karaⅱ engRex karaⅱ eng
Rex karaⅱ eng
 
E 013 diode laser user manual
E 013 diode laser user manualE 013 diode laser user manual
E 013 diode laser user manual
 
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIASV5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
V5PRO MANUAL.MAQUINA REDUCCION DE MEDIAS
 
Manual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizadoManual de usuario ultrasonido focalizado
Manual de usuario ultrasonido focalizado
 
High frequency
High frequencyHigh frequency
High frequency
 
Cosderma Triple wavelength diode laser
Cosderma Triple wavelength diode laserCosderma Triple wavelength diode laser
Cosderma Triple wavelength diode laser
 
Uja1.0 slimming machine
Uja1.0 slimming machine Uja1.0 slimming machine
Uja1.0 slimming machine
 
Yinhe 808 user manual
Yinhe 808 user manualYinhe 808 user manual
Yinhe 808 user manual
 
Fractional co2 laser operation instruction
Fractional co2 laser  operation instructionFractional co2 laser  operation instruction
Fractional co2 laser operation instruction
 
Portable 808-Brochure
Portable 808-BrochurePortable 808-Brochure
Portable 808-Brochure
 
Jay 1 neutral user manuel
Jay 1 neutral user manuelJay 1 neutral user manuel
Jay 1 neutral user manuel
 
mp_c3004.pdf
mp_c3004.pdfmp_c3004.pdf
mp_c3004.pdf
 
E 146 multifunctional eye & face&neck device
E 146 multifunctional eye & face&neck deviceE 146 multifunctional eye & face&neck device
E 146 multifunctional eye & face&neck device
 
Forimi SHR Machine FMS-1
Forimi SHR Machine FMS-1Forimi SHR Machine FMS-1
Forimi SHR Machine FMS-1
 
Body Care Machines and Laser Hair Removal Equipment By LaserHeal
Body Care Machines and Laser Hair Removal Equipment By LaserHealBody Care Machines and Laser Hair Removal Equipment By LaserHeal
Body Care Machines and Laser Hair Removal Equipment By LaserHeal
 
Detecteur de champ magnetique
Detecteur de champ magnetiqueDetecteur de champ magnetique
Detecteur de champ magnetique
 
Taiyi fiber laser marking machine manual english edition
Taiyi fiber laser marking machine manual english editionTaiyi fiber laser marking machine manual english edition
Taiyi fiber laser marking machine manual english edition
 
Ръководство Xiaomi Mi Roborock 2
Ръководство Xiaomi Mi Roborock 2Ръководство Xiaomi Mi Roborock 2
Ръководство Xiaomi Mi Roborock 2
 
Medical Infrared Thermometer - K1176079898
Medical Infrared Thermometer - K1176079898Medical Infrared Thermometer - K1176079898
Medical Infrared Thermometer - K1176079898
 

Recently uploaded

ASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptxASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptx
AnushriSrivastav
 
ASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptxASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptx
AnushriSrivastav
 

Recently uploaded (20)

CHAPTER- 1 NATIONAL-POLICIES-AND-LEGISLATION.pdf
CHAPTER- 1 NATIONAL-POLICIES-AND-LEGISLATION.pdfCHAPTER- 1 NATIONAL-POLICIES-AND-LEGISLATION.pdf
CHAPTER- 1 NATIONAL-POLICIES-AND-LEGISLATION.pdf
 
The Pfizer testimony by Melissa Mac Atee
The Pfizer testimony by Melissa Mac AteeThe Pfizer testimony by Melissa Mac Atee
The Pfizer testimony by Melissa Mac Atee
 
Management of Colorectal Cancer for the Trainee Surgeon
Management of Colorectal Cancer for the Trainee SurgeonManagement of Colorectal Cancer for the Trainee Surgeon
Management of Colorectal Cancer for the Trainee Surgeon
 
Leaukemia and it cause sign and symptoms
Leaukemia and it cause sign and symptomsLeaukemia and it cause sign and symptoms
Leaukemia and it cause sign and symptoms
 
Best Way 30-Days Keto Meal Plan For Diet
Best Way 30-Days Keto Meal Plan For DietBest Way 30-Days Keto Meal Plan For Diet
Best Way 30-Days Keto Meal Plan For Diet
 
ASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptxASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF BED PAN BY ANUSHRI SRIVASTAVA.pptx
 
ASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptxASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptx
ASSISTING WITH THE USE OF URINAL BY ANUSHRI SRIVASTAVA.pptx
 
Storage_of _Bariquin_Components_in_Storage_Boxes.pptx
Storage_of _Bariquin_Components_in_Storage_Boxes.pptxStorage_of _Bariquin_Components_in_Storage_Boxes.pptx
Storage_of _Bariquin_Components_in_Storage_Boxes.pptx
 
pathology seminar presentation best ppt by .pptx
pathology seminar presentation best ppt by  .pptxpathology seminar presentation best ppt by  .pptx
pathology seminar presentation best ppt by .pptx
 
Breaking Down Oppositional Defiant Disorder Treatments
Breaking Down Oppositional Defiant Disorder TreatmentsBreaking Down Oppositional Defiant Disorder Treatments
Breaking Down Oppositional Defiant Disorder Treatments
 
Occupational Therapy Management for Parkinson's Disease - Webinar 2024
Occupational Therapy Management for Parkinson's Disease - Webinar 2024Occupational Therapy Management for Parkinson's Disease - Webinar 2024
Occupational Therapy Management for Parkinson's Disease - Webinar 2024
 
Dr. Gaurav Gangwani: Leading Interventional Radiologist in Mumbai, India
Dr. Gaurav Gangwani: Leading Interventional Radiologist in Mumbai, IndiaDr. Gaurav Gangwani: Leading Interventional Radiologist in Mumbai, India
Dr. Gaurav Gangwani: Leading Interventional Radiologist in Mumbai, India
 
Boost Your Brain: Discover Natural Herbal Memory Supplements for Enhanced Cog...
Boost Your Brain: Discover Natural Herbal Memory Supplements for Enhanced Cog...Boost Your Brain: Discover Natural Herbal Memory Supplements for Enhanced Cog...
Boost Your Brain: Discover Natural Herbal Memory Supplements for Enhanced Cog...
 
Importance-of-Protein-During-Pregnancy Time
Importance-of-Protein-During-Pregnancy TimeImportance-of-Protein-During-Pregnancy Time
Importance-of-Protein-During-Pregnancy Time
 
Chris Shade BS MEd MS LPC-Associate "Presume" (What Do I Do?)
Chris Shade BS MEd MS LPC-Associate "Presume" (What Do I Do?)Chris Shade BS MEd MS LPC-Associate "Presume" (What Do I Do?)
Chris Shade BS MEd MS LPC-Associate "Presume" (What Do I Do?)
 
Renal Replacement Therapy - ICU Guidlines
Renal Replacement  Therapy - ICU GuidlinesRenal Replacement  Therapy - ICU Guidlines
Renal Replacement Therapy - ICU Guidlines
 
Pharmacology and Toxicology Thesis Defense by Slidesgo.pptx
Pharmacology and Toxicology Thesis Defense by Slidesgo.pptxPharmacology and Toxicology Thesis Defense by Slidesgo.pptx
Pharmacology and Toxicology Thesis Defense by Slidesgo.pptx
 
Master the Art of Yoga with Joga Yoga Training
Master the Art of Yoga with Joga Yoga TrainingMaster the Art of Yoga with Joga Yoga Training
Master the Art of Yoga with Joga Yoga Training
 
For Better Jaipur #ℂall #Girl Service ❤89011-83002❤ Jaipur #ℂall #Girls
For Better Jaipur #ℂall #Girl Service ❤89011-83002❤ Jaipur #ℂall #Girls For Better Jaipur #ℂall #Girl Service ❤89011-83002❤ Jaipur #ℂall #Girls
For Better Jaipur #ℂall #Girl Service ❤89011-83002❤ Jaipur #ℂall #Girls
 
Homeopathy Medicine for Diabetes_ Balancing Blood Sugar .pdf
Homeopathy Medicine for Diabetes_ Balancing Blood Sugar .pdfHomeopathy Medicine for Diabetes_ Balancing Blood Sugar .pdf
Homeopathy Medicine for Diabetes_ Balancing Blood Sugar .pdf
 

Yinhe King User Manual

  • 1. E-light+Laser Multifuctional Beauty Equipment Yinhe-King USER MANUAL Please read this manual carefully before operating this machine and Retain it for future reference. For your safety 1.Before open the machine,you must fill the water to this machine until the water automatically come out of overflow,means the water is full of water tank. or it will
  • 2. easily make it broken. 1.Keep any reflecting things out of the operating room,such as mirror,watch,jewellery... 2.Operator and the patient must wear the professional protective glasses and googles. 3.Any intense pulsed light without correct using can injure the body. In the course of working,the device will produce high pressure.So every operator should keep warning, operating according to this introduction. 4.Patient:Well-trained operator and appropriate disposal treatment room is very necessary and important.Moreover,the patient should also know the treatment theory and wear the professional protective eyepatch, protecting eyes from burning. 5.Operator:Durng the treatment, it’s possible to touch the intense pulsed light,so it’s necessary to wear the professional protective glasses. 6.Treatment room: the room must clear mark “using intense pulsed light” 7.Except the authorized mechanic, anyone have no right to examine and repair the machine,especially the inside of device that including electrical source, cooling system,optical organs and treatment head.Notice the dangerous high pressure inside. 8.Make sure whether it’s accordant to your resident voltage or not. 9.Maintenance must after turning off the device and drawing out the electrical source line.Or it’s most possible to injure people and damage the equipment. 10.Keep the filter and the probe clean. 11.Stop turning on when finding slack from treatment head. If turning on, close right now. 12.Over light energy could burn skin, that results in atrophy or pigment deposit. 13.Do not directly see the intensed pulsed light during treatment,even wearing the protective glasses and eyepatch. 14.Do not allow to point the treatment handpiece to the air.Generally,hang it in the bracket of the machine. 15.High pressure inside the equipment. It’s possible to deposit electricity in some parts even after switching off. So it’s not allowed to open equipment beyond the authorized mechanics. 16.When maintaining, please close power, cover board, and observe in person. 17.Total weight is a little heavy, so please take care when moving. 18.The temperature will raise after absorbing light energy, so please take actions to reduce the flammable risk on treatment parts or around area. 19.Do not use ethanol, acetone or other flammable things on skin before treatment.If necessary,please use soap or water. 20.When listerizing the treatment head or other parts in ethanol, please wait till dry Who is forbidden? 1.People who are allergic to light. 2.Pregnant women,Diabetes suffers,cardiac patients,people with Hypertension,Epilepsy and skin cancer.
  • 3. 3.People with cardiac pacemaker and defibrillator. 4.People whose treatment parts are damaged. 5.People are just back from the beach.The skin is very weak after the exposure in the sun in this time. 6.People have taken some photosensitive food or drug recently. Important Information This user's guide contains important information on the use and operation of this machine.Please read all the information carefully for optimal performance and to prevent any damage to or misuse of the machine.Any changes or modifications not expressly approved in this user's guide could void your warranty for this equipment. Overview  Accessories Check to make sure you have all parts shown below.
  • 4. Fileter E-light handle Key Remarks: 1.Power line:to connect machine 2.Foot switch:for operation 3.Treatment handpiece:for treatment 4.Trips:part of the treatment head 5.Protective glasses:for operator; Protective goggles:for patients 6.Keys:main switch to open and close the machine 7.Watering bottle:for filling water to the machine Part of the machine Front of the Machine
  • 5. Picture one Pay attention: 1.Place the device on the level ground.(If there’s water on the surface of the device,please wait till dry then input water to test).Keep 22℃-28℃ temperature and the humidity not more than 20% in the treatment room. a. If there’s something hurt suddenly happened,press down the Red button(Emergency switch) at once.If you do not move the machine to long distance place,do not press down the emergency button.When you finish the treatment,just close the key switch and pull out the power line rear of this machine. 3.Gently turn the Emergency switch( red button) towards right before opening key switch.Usually the button will bounce at once,If not,you should continue to revolving the red button until it’s absolutely bounce. Laser handle Display screen Key switch Emergency button E-light handle
  • 6. 1.1.Laser Part Principle of Treatment Laser uses the high energy laser beams emitted by a sapphire to effectively smash pigments inside pathologically changed tissues, i.e. light explosion and photo-thermolysis principle: the high energy produced by the laser is emitted instantly, so that laser beams with a fixed wavelength can penetrate the epidermis into pathologically changed tissues within a certain working time (12ns), and quickly smash corresponding pigments, which expand rapidly and explode instantly due to extreme heat. A part of the pigment cluster (on the surface of the epidermis) pops out of the body, a part of the pigment cluster (inside basal tissues) are smashed into fine particles that can be devoured by macrophages, while some dirt and cuticle remaining on skin epidermis are smashed and decomposed by the principle of active carbon explosion, then devoured and digested by macrophages, and finally expelled out of the body via the circulation of the human lymphatic system, thus the pigments in the pathologically changed tissues will fade out and disappear gradually. And yet no damage will be done to the normal skin tissues in the vicinity since they do not absorb laser beams with a certain wavelength. b. Applications: 1) Removalof eyebrow line, eye line, lip line...etc 2) Removalof tattoo(red, blue, black...etc) 3) Clearance speckle, black naevus, fleck, age spots...etc 4) Removal of vascular lesion and spider vessel...etc
  • 7. c. Feature and Benefits: 1) Innovative in laser technology, strict in technical detection, precise in manufacture. 2) Special designed cooling system ensures constantly working. 3) New fashionable outlook design. 4) Portable and aseismatic, convenient for transportation. 5) No injury to normal tissue. 6) Remove pigmentation without side effects or scar. 7) Accurate infrared indication light makes the spot position more accurately and increases the utilization of light point A Operating Instructions When the instrument is turned on, the welcome screen (Figure 1) will show up. Press any button to enter into the treatment screen: Screen Display:
  • 8.
  • 9.
  • 10.
  • 11. After having entered into the treatment screen, the operator can press the Frequency
  • 12. button and Voltage button to adjust working frequency and working voltage. Press the first button to the left (Trigger). When the xenon lamp is successfully turned on, the button status indication will show an “inverse effect”. Press the Working button to enable working, an “OK” symbol will show up in the status indication zone. Then, the operator can start working by stepping on the foot pedal. During working, a pulse count is added whenever a pulse is released. To turn off the instrument, first press the Working button to stop working, then press the Trigger button to turn off the xenon light, and lastly turn off the power switch. During working, the operator can directly press the Trigger button to exit pre-ignition. When the foot pedal is stepped on, all the buttons will not work. Introduction to Operation for Treating Various Defects Removing Tattooed Eyebrow 1. Removing Monochromatic Blue or Black Tattooed Eyebrow During operation, the patient should not open his/her eyes. The operator selects the required laser energy according to the depth of the tattooed eyebrow (adjust laser beams to a suitable energy level), and holds the laser gun by hand and slowly moves the gun close to the area to be treated from the normal skin around the area, so as to help the patient adapt psychologically. Then, the operator can set the laser beam emission rate to 5Hz, and perform the treatment when the gunpoint is 1-2 fingers width away from the area to be treated. It is OK to start treating from the tail of the eyebrow or the head of the eyebrow. If there is a sign of color recovery within 5-10 minutes after treatment, second treatment can be performed. At this time, the energy level should be 20-40 units higher than that used for the first treatment. The gunpoint should be 1-2 fingers width away from the area to be treated, so as to further smash pigments and boost absorption by the body. Check the result one and a half month later. For a patient who has some remaining pigments, second treatment can be performed. (If the energy cannot be absorbed due to faded color, active carbon can be applied for the treatment in order to facilitate energy absorption.) 2. Removing Makeup Tattooed Eyebrow (it will take 2-3 times of treatment to completely remove makeup tattooed eyebrow) The operator can set the laser beam emission rate to 3 Hz. First use a 1064nm light head to perform the treatment with the gunpoint placed at a distance of 2-3 fingers width away from the area to be treated. Then use a 532nm light head to perform the treatment. Since coffee (brown) color is a mixed/harmonizing color, treatment usually needs to be performed more than two times, and the interval of treatment is 45-90 days. When performing treatment for the second time, the operator should select a light head according to the remaining color. (If the energy cannot be absorbed due to faded color, active carbon can be applied for the treatment in order to facilitate energy absorption.)
  • 13. 3. Removing Tattooed Eye Lines The operator can set the laser beam emission rate to 3 Hz. Adjust the laser energy to the lowest level (initial laser beam emission value), and place the gunpoint at a distance of 1-2 fingers width away from the area to be treated – it will be just right when the light spot can be seen by eye! The operator must use a piece of thick medical gauze or an eyelid patch to well protect the eyes. First, the operator should remove the lower tattooed eye line – ask patient to tightly close his/her eyes and “look” upward at the same time. The operator uses his/her forefinger to hold the gauze and push the upper eyelid upward, uses his/her middle finger to open the lower eyelid to expose the lower eye line and uses 5Hz laser beams to perform the treatment. After this, the operator can remove the upper tattooed eye line – ask the patient to tightly close his/her eyes and “look” downward at the same time, while the operator uses his/her middle finger to hold the gauze and press the eyelid downward, uses his/her forefinger to push the eyelid upward to expose the upper tattooed eye line, and uses 5Hz laser beams to perform the treatment. 4. Removing Tattooed Lip Lines The operator can set the laser beam emission rate to 5Hz, and place the gunpoint at a distance of 3-4 fingers width away from the area to be treated. When removing black, coffee, crimson or brown lip lines, the operator should first use a 1064nm light head to perform the treatment, and then repeat with a 532nm light head. When removing light red, red, light coffee or light brown eye lines, the operators should use a 532nm light head to perform the treatment. Attention: Treatment must be performed on all tattooed lip lines within half a year after tattooing. Otherwise, the operation will fail. The course of treatment is 45-60 days. Periodical treatment should be performed until lip line tattoo is clear. 5. Removing Tattoo, Birthmark, Venus of Ota and Nevus Spilus The operator can set the laser beam emission rate to 3-5Hz, place the gunpoint at a distance of 3-4 fingers width away from the area to be treated, and use the energy as close to the focal high energy as possible to perform the treatment. The result will be the best if bleeding spots show up. For removing common dark blue marks, the operator should select a 1064nm light head to perform the treatment. For removing red or coffee marks, the operator should select a 532nm light head to perform the treatment. The course of treatment is 45-90 days. Periodical treatment should be performed until the mark is cleared (if the energy cannot be absorbed due to faded color, active carbon can be applied for the treatment in order to facilitate energy absorption). For treating a birthmark and nevus spilus, we recommend the use of a 1064nm light head. For treating a birthmark, the treatment must be performed until bleeding shows up. For treating a nevus of spilus, the result will be the best if bleeding spots show up. If a 1064nm light head is ineffective for treating a dark color birthmark, a 532nm light head can be used to perform the treatment. The course of treatment is 45-90 days. Periodical treatment should be performed until the mark is cleared. 7.Skin Rejuvenation
  • 14. 8. Reaction During Operation Due to the instant radiation of high energy laser beams, the pigment cluster of pathologically changed tissues quickly decomposes into fine particles that can be devoured by macrophages in the human body; some pigments on the epidermis instantly pop out of the body, while other pigments inside deep layer tissues are evenly distributed to the epidermis. Therefore, the color will be recovered somewhat within a short period of time after operation. When tissues with a dark color or deep lines are treated, local signs of redness, blain or even bleeding spots may occur due to the intense absorption of laser energy by melanin. These are normal reactions of the tissues. The degree of local inflammation varies with different patients. When inflammation is alleviated, the patient may feel itching or tissue hardening when touching the tissue. In general, all these will disappear naturally within 3-7 days after operation. They may last for 1-3 months for some patients with poor physical conditions. 9. Caring after Operation Within 1-3 days after operation, the patient should never apply make up on the eyebrow, washing or touching the bleeding area, lest it might cause infection. The patient should pay attention to sunscreening to prevent sunlight from causing hyper-pigmentation. For a patient having serious bleeding or swelling, he/she can take some antibiotic medicines such as acetylspiramycin according to the instruction of his/her doctor. In 72 hours after operation, the patient should coat the treated area with recover/repairing cream to facilitate healing. The patient should avoid direct UV radiation. Taking vitamin C orally can alleviate pigment return. Before the crust peels off, the treated area should not be in contact with water or be rubbed. Within one week after operation, the patient should give
  • 15. up spicy food, seafood, irritating food, cigarette and wine, and never have dark color food such as coffee and cola. The patient should let the crust peel off naturally. Within one week after pigment treatment the patient should not have sex in order to prevent pigment return. Pigment fading away is a slow process, which is usually one and a half month or so. If a patient needs to be treated again in order to achieve the best result, the interval of treatment should be about 2 months. The treatment for some defects may need to be performed for multiple times according to the nature of pathological change, the shade/depth of pigments, and different areas.  Installation E-Light Part E-Light Beauty System Theory It combines three advanced technologies: Bipolar Radio Frequency + IPL +Skin Contact Cooling. When the three are united in one treatment, wonderful treatment experience and result can be expected. The energy of Radio Frequency can reach the middle and deep layer of the skin and heat up tissue, thus, lower energy is applied during the IPL treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and better result can be expected. In addition, cooling system involved in E-light can also ease the uncomfortable feeling. The absorbing of the energy of radio frequency is not concerned with melanin. So, the E-Light treatment can get good result on the soft or thin hair so as to decrease the risk caused by traditional IPL treatment.
  • 16. Application Range 1.Remove undesired hair permanently from various areas of the body for all kinds of hair color; 2.Remove specklesage spotsun-induced freckles from various types of skin; 3.Remove facial vascular lesions; 4.Skin rejuvenating and lessen deep wrinkles; 5.Tighten skin and remove acne. 6.Skin whitening. Advantage 1.Remarkable effects on fuscous spot and live spot 2.Great effect on unwanted hair removal, both thick black hair and tiny hair, and comfortable during the treatment 3.Avoid burn, pigment mark and blister during former IPL treatment 4.Wide range of treatment, great effect, and with high safety factor 5.Large color touch screen, comfortable and elegant 6.Breakthrough based on traditional IPL technology  Operation Steps
  • 17. 1.There's five modes in all,take skin rejuvenation as an example: 2.Start to operate 2.1 Choose filter for Skin rejuvenation 530nm,set up it to the treatment head 2.2Choose the treatment mode,touch the Key [skin rejuvenation] 2.3 Begin to operate after touch the [Standby] first,at this time, [Ready] will show you. Pay attention:the treatment head must close to the surface of skin,gently press down the green or yellow button of the treatment head.Of course you could also use foot touch to operate.in this case,you do not need to press down two buttons of the head.Just steps on the E-light foot switch. If you finish this operation: Step one:you just need to touch this [Ready] key,then back to Pic.3. Step two:turn off the key switch ,you need to turn the key to left. According to the above statement, other treatment modes can be operated like it. The technical parameters of operation *640nm,690nm--Hair Removal *530nm--Pigmentation Therapy,Spots Removal,Skin Rejuvenation *580nm,590nm--Vascular Therapy *480nm,430nm--Acne Treatment Pay attention:the filters above are optional Pay Attention: The parameters above are just as your reference,you'd better start a little smaller energy the first operation,then ask the patients if they feel like a slight tingling or a pinch similar to the snap of a rubber band.IF yes,continue to treat,or you try to increase the parameters gradually two by two,like 10/12/14...For first treatment,we suggest IPL energy start from 6.You'd better repeat to shot the same treatment area. Hair Removal Hair Removal a. one course in all,every months as one treatment,4-6 treatments in all.Usually,very significant effect will show you after 2-3 treatments. For thick hairs,it needs 3 treatments.For soft and thin hair,it needs 5 treatments.Treatment time:For two arms:in 1.5 Pre-operation Clean skin Apply even gel on skin
  • 18. hours;For two legs:in 1.5 hours;For armpit hairs:in 30 minutes. d. Effect of cooling gel: cooling and light transporting e. Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20 minutes after the treatment, scrape the cooling gel, or cooling with ice for 10-20 minutes f. Operating sequence: shave away unwanted hair or shear the unwanted hair, 1-2mm to the hair root first,then Clean skin and spread cooling gel on the treatment area; after the treatment, make an ice cooling treatment. Skin Rejuvenation(530nm) Skin Rejuvenation a. one course in all,every 3 weeks one treatment,4-6 treatments in all.Usually,very significant effect will show you after 2-3 treatments.For face treatment,it needs about 30 minutes. b.Pre-operation:deeply skin cleaning,remove acne,blackhead c. Feelings in the treatment: Swollen feelings inside skin.A little inflamed feelings on skin after the treatment. d. Effect of cooling gel: cooling and light transporting e. Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for 10-20 minutes f. Operating sequence: Clean skin and spread cooling gel on the treatment area; after the treatment, make an ice cooling treatment.
  • 19. Acne Treatment(480nm) Acne Treatment a. 1-2 course.(very serious skin problems,it needs 2 course),3 weeks one treatment.4-6 treatments in all,very significant effects show after 2-3 treatments. b. Pre-operation:deeply clean skin. c. Feelings in the treatment: very Swollen feelings inside skin.A little painful inflamed feelings on skin after the treatment. d. Effect of cooling gel: cooling and light transporting e. Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for 10-20 minutes f. Operating sequence: Clean skin and spread cooling gel on the treatment area; after the treatment, make an ice cooling treatment. Vascular Therapy(530nm)
  • 20. Vascular Therapy a. 4-6 treatments as one course,3 weeks apart,one or two course in all.Very obvious effects will show you after 2-3 treatments. b. Feelings in the treatment: Swollen feelings inside skin.A little inflamed feelings on skin after the treatment. c. Effect of cooling gel: cooling and light transporting d. Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for 10-20 minutes e. Operating sequence: Clean skin and spread cooling gel on the treatment area; after the treatment, make an ice cooling treatment. Pigmentation Therapy(530nm) Pigmentation Therapy a. 1-2 course(2 course is for very serious skin problems,like serious chloasma),3-4 weeks one treatment,4-6 treatments in all. b.Treatment symptoms:the freckles become darker after one treatment,the treatment area will be red,the freckles will gradually be light and drop off. c.Feelings in the treatment:some pain feelings like needle pricking. In one week after the treatment, spots will be darker first.Usually after one cycle treatment,the perfect results will show you.ffect of cooling gel: cooling and light transporting e.Usage: spread the cooling gel on the treatment area before treatment, about 3mm thickness; 20 minutes after the treatment, scrape the cooling gel, and cooling with ice for 10-20 minutes
  • 21. f.Operating sequence: Clean skin and spread cooling gel on the treatment area; after the treatment, make an ice cooling treatment. Maintenance 1.No stress on the Screen, prevent from breaking up 2.Keep the filters and probe clean,do not let the cooling gel enter into probe. We suggest you slightly clean the filters' wafer after each treatment with soft and clean paper towel,if it's very dirty on its wafer,please Dip the paper towel in a little dehydrated alcohol.then clean it.just as follows: 1.Filters and Treatment head  Operation 1.Normal watering:Screw off the little screw cap from overflow,then Input water(pure water or distilled water):Connect the watering bottle and inlet well,when there’s water automatically spill from the overflow,means the water is full of the water tank,at this time you have to keep the outlet closed. 1.1 Change the water inside of the machine every 10-15 days if you use the machine very often. 1.2 When changing water,just screw off the screw of outlet.(You’d better put a water container under it) 1.3 Our Apparatus is equipped with powerful cooling system,after five minute's working,you have to filling water again till there's water automatically spill from the spilt hole.For this new machine,if the probe is very hot in the beginning 10 seconds working,please do not hesitate to close it right now.Then shaking this treatment head 3 times over your head,in this case,the water of the head will flow back into water tank.If the
  • 22. probe is still hot,you can just repeat this action. Please never power on the equipment if you do not fill water in it. 2.Insert the relevant filter to the E-light treatment handle, then turn on the key switch. After that, please observe the water circulation inside the device. Normally, you will hear the sound of water flow. The probe runs cold in 1-2 minutes, at this time, you have to turn on the cooling switch at the rear of this machine, just press it. If the treatment head is too cooling, then please turn off it for a while. 3. Starting up 3.1 Press any point on the screen ,the screen will show you as follows: 3.2 Press to come into the following setting screen:
  • 23. press return back to the picture 2. There are six modes:hair removal, skin rejuvenation ,pigmentation therapy, vascular therapy, acne therapy, wrinkle removal. Choose any one that you want to do, let us take hair removal for example. Pre-operation 1.clean skin, record detail skin conditions. 2.remover the hair of the treatment area. 3.spread cooling gel on the treatment area, about 3-5mm. 2.Start to operate 2.1 Choose filter for hair removal 640nm,set up it to the treatment head 2.2Choose the treatment mode,touch the Key [hair removal] 2.3Adjust the parameters according to the feeling of patient
  • 24. saving buttons, after adjusting the parameters ,touch any saving button,this parameters can be saved in it, then you can receive the parameters by touch the saving button. press to increase or decrease energy of IPL and RF. adjust cooling lever. When you adjust the pulse width,pulse delay and frequency,you should touch the button needing adjust ,then touch the 2.4 Begin to operate after touch the first,at this time, then will be lighted IPL energy RF energy Counter Pulse width Pulse delay Frequency
  • 25. Pay attention:the treatment head must close to the surface of skin,gently press down the green or yellow button of the treatment head.Of course you could also use foot touch to operate.in this case,you do not need to press down two buttons of the head.Just steps on the E-light foot switch. 2.5If you finish this operation: Step one:you just need to touch this key,then will be off. Step two: touch to turn back to picture 2. Step three: turn off the key switch , you need to turn the key to left. According to the above statement, other treatment modes can be operated like it. Warns after treatment and Maintenance  Warnings after treatment 1.Pay attention:In one month after treatment,the patient should use sunscreen SPF15,when going out,you'd better take an umbrella and wearing a hat in case of sunburn.If your skin expose in the sun,it will increase the regeneration rate of melanoma,directly result in excessive pigmentation. 2.You should often use moisture mask to supply water to your skin.Keep your skin retain water.You'd better use a mask before treatment. 3.Do not make up immediately after treatment.You'd better use the pure biological skin care products,not chemical products and the silty cosmetics.If there's flare on treatment area,a doctor should be notified immediately and stop make-up.Take some VitC or VitE. 4.Treatment course:6-8 times as one course,2-3 course in all.The next treatment should be carried out after 3 weeks .After one course treatment,the problems such as age spots,spots,ect will be solved,the skin becomes shiny and flexible. 5.As physical differences in personal,individual customers may be temporary discomfort,small blisters,pigmentations,flare,in this case,we suggest you use ice pack for 30 minutes,you can make up 5 days later after treatment.  Maintenance 1.No stress on the Screen, prevent from breaking up 2.Keep the filters and probe clean,do not let the cooling gel enter into probe. 3.The handle is fragile, please take care when pick up and dropt it in the bracket. 4.Every 15 days to change the water. After changing water, please make sure water circulate normally before usage. If the probe continuing be in high temperature after continuing working too long.you could change half of water from the machine.In this case,the temperature will reduce at once. 5.To keep the powerful energy,we suggest you change the water after 3000 shots. 6.Please check the surface of treatment head if there's attachement object after
  • 26. treatment,if so,please lightly clean it with lens paper or absolute alcohol.  Malfunction and solutions 1.No power supply: a.Check up whether there is power sup b.Check up whether the power line is connected well. c.Check up the fuse, which could be pulled out at the bottom of hole for power plug. d.Check up if you open the key switch and emergency switch. Solution: a.connect well the power line b.change the fuse; c.open the key switch and release the emergency switch button 2.Non-Refrigeration after opening the machine: a.cooling electric source is broken b.Semiconductor is broken c.there's air in the treatment head,non well water circulation Solution: Contact us directly 3.Treatment Head leakage: a.the srews of the head loose b.the water pipe inner of the head has dropped down c.lamp or crystal of the head is broken Solution: Contact us 4.The Treament head can't light on: a.The head is broken b.The controller is broken c.The Power line is broken Solution: Contact us No Flashing a.Do not control well of the switch on the treatment head b.Make the wrong operation c.The controller is broken d.The power line is broken e.Need to change a new treatment head. Solution: Contact us