SlideShare a Scribd company logo
1 of 19
COOLINGTOWERMANUFACTURER
ENGINEERINGANDDESIGN
WATERPUMPS
HEATEXCHANGERS
HEATERS
STORAGE TANKS
ETC.
Mission
At CTS, we provide high quality customer service. We strive to create a culture of teamwork with
positive communication to drive company innovation and ensure customers receive the most cost
effective and energy efficient cooling towers, empowering their company to meet and exceed their
desired thermal performance and production goals for your water-cooled equipment.
Vision
Our vision is to support all
involved in the cooling
tower industry to be
proactive in selecting
equipment that is cost
effective and energy
efficient to meet challenges
faced in the field and in this
everchanging world.
CTS Customer Base and History
◦ Among our satisfied customers you will find OEM representatives (Other Equipment Manufacturers), industrial contractors, mechanical
consulting and design engineers, chemical manufacturers, food and beverage manufacturers and processors, refrigeration warehouse
companies, industrial buyers, utility companies, a large dry-cleaning market, etc.
◦ Cooling Tower Systems product line is within 74 countries with direct representation worldwide.
◦ Cooling Tower Systems is a manufacturer’s representative for cooling tower lines and related equipment for over 35 years. We have many different
models of cooling towers in production, to include counter flow induced draft, counter flow crossflow, fluid cooling towers (closed loop system),
high temperature cooling towers, industrial cooling towers, low noise cooling towers, etc.
◦ Our most common cooling tower we sell into the North and South America would be our counter flow induced draft, FRP (non-corrosive)
cooling tower models, which is more energy efficient, cost effective, non-corrosive nature, and would be considered our most desirable model.
◦ CTS has been a member of the Cooling Tower Institute (CTI) since 1972 and rate our cooling towers per their specifications. We are CTI
certified on our R-LC model line and will give a manufacturer CTI certification stating that all models of cooling towers that we select,
using proper design conditions, will meet and exceed STD-201 CTI certification.
Three Main Reasons to Buy
A CTS Cooling Tower
1. Non-Corrosive Nature of Cooling Tower
 The hot and cold deck are manufactured from PVC and FRP (Fiberglassed Reinforced Polyester). All steel components have a quality hot dip
galvanizing that does resist corrosion. All fasteners on our cooling towers are 304 stainless steel in nature. We also have the capability of
manufacturing all support components in 304 stainless steel.
2. Energy Efficiency
 Our counterflow induced draft cooling towers allow us to be more energy efficient than a conventional tower. This is because it is a round
circular type cooling tower with fresh intake from center of tower, 360 degrees around it. This allows an increase of fresh air supply verses a
conventional cross-flow or counter-flow cooling tower, which only draws air from two sides of the system. Our counter flow induced cooling
towers will use less fan motor horsepower when compared with other conventional style cooling towers.
3. Warranty
◦ Cooling Tower Systems, Inc. offers the best warranty in the industry, which is 20 years on the FRP (fiberglass reinforced polyester)
components that are manufactured with a gel coating to protect it from ozone’s and UV lights. Our FRP is mixed with a gel coating that
strengthens and protects it from the UV (ultraviolet) light rays in the ozone. This provides a higher resistance to rot and decay to all FRP
portions of the cooling towers in extreme climate environments.
◦ The reason we can give a 20-year warranty verses others in the industry that give up to a 5 years warranty, is due to the FRP of tower to
include the casing and cold-water basin. They have been gel coated during the manufacturing process, providing protection from UV
ultraviolet ozone.
Unique Features of a CTS Cooling Tower
Quality
◦ Our cooling towers are non-rusting, FRP, counter flow, and induced draft. Its unique design allows water to
recirculate and evaporate out the top of the tower. Our standard drift loss on T-2 models is approximately 0.1% of
circulating water. CTS offers a Drift Eliminator Assembly that can decrease the loss of water to approximately
0.05%. The interior of this assembly has an S like structure so that water is not vaporized and then returned to the
cooling tower.
Maintenance
◦ Due to the round and constant motion of water in our cooling towers, this makes it very difficult for bacteria and
mold to grow. Water is never stagnant in the cooling tower and is constantly being recirculated.
◦ We do have operation and service manual that needs to be reviewed and followed before a cooling tower is put into
service.
◦ This information is available and downloadable from our website at www.coolingtowersystems.com
Accessories Sold with CTS Cooling Towers
Water Pumps: CTS has a quality line of water pumps, specially designed for our cooling towers. This product line allows users to maintain higher levels of efficiency over a
wider range of operating conditions. Light weight and low noise. Suction and discharge connections are inline designed in the same size as towers to simplify piping in any
direction for installation. All water pumps come with a TEFC motor for outdoor use.
Immersion Heater: CTS has developed a full line of winterization kits. We provide both screw type heaters with thermostats and bottom mount heaters with control panels.
These are installed in the basin of the cooling tower to protect them from freezing during the cold weather months.
In cold climate using immersion heaters with an on and off thermostat control panel keeps the cold-water basin from freezing.
Heat Exchanger: A system that combines a cooling tower with a plate heat exchanger, and you'll save money from day one. You'll also get a system that maintains effective
fluid isolation and cools HVAC or process liquids more efficiently. A tower system with a heat exchanger is far less expensive to buy than any evaporative cooler. Couple the
tower and the heat exchanger, and you also get a more efficient system that's cheaper to run, incorporates superior stainless-steel components, uses colder water (not glycol),
and requires smaller components — including heat pumps — with lower horsepower.
Storage Tank: Above ground, horizontal and vertical storage tanks are available for the purpose of storing water during the hot or cold weather months. Features tie-down
slots, built-in graduation gallon-count indicators, siphon tube, offset fill-well and self-vented, slosh proof lids. Vertical storage tanks are most frequently used for nursing mobile
application equipment and bulk storage. In a cold climate for winter use it is preferred not to use the cold-water basin for your processed water, instead elevate the cooling
tower outside so after you get your desired thermal performance all the cooling towers processed water will flow inside into a remote processed water tank that is in a
controlled atmosphere.
T-2250
Single Cell System
BTU/hr 3,750,000
T-3250
Multi-Cell System
BTU/hr 18,750,000
T-3000
Multi-Cell System
BTU/hr 15,000,000
CTS Cooling
Towers
T-2 Model
T-23 (3 ton) up to
T-2800 (800 ton)
T-3 Model
T-3000 (1000 ton)
T-3250 (1250)
T-3500 (1500 ton)
CCT Model
CCT-3 (3 ton) up to
CCT-15 (15 ton)
Special Order
LLC Closed Circuit
RLC CTI Certified
CCT-237-10
10 Nominal Tons Based on
Design Condition of
95/85/75 @ 30 GPM
•This is 10 nominal ton cooling
with sump pump and electrical
switches installed and tested.
•Equipped with a dual on/off
switch - one for the motor and
one for the sump pump
•Wired and tested to low voltage,
single phase electricity
•Common uses include small
process cooling, machinery
cooling, and pond cooling
applications.
T-280
80 Nominal Tons Based on
Design Condition of
95/85/75 @ 237 GPM
BTU/hr
1,200,000
T-2125
125 Nominal Tons
Based on Design Condition of
95/85/75 @ 369 GPM
BTU/hr
1,875,000
T-2200
200 Nominal Tons Based on
Design Condition of
95/85/75 @ 592
BTU/hr
3,000,000
T-2500
500 Nominal Tons of
Cooling Tower based on
Design Condition of
95/85/75 @ 1,505 GPM
BTU/hr
7,500,000
T-3250
1,250 Nominal Tons Based
on a Design Condition of
95/85/75 @ 3,761 GPM
BTU/hr
18,750,000
T-2700
Ontario,
California
700 Nominal Tons Based
on Design Condition of
95/85/75 @ 2,101 GPM
BTU/hr
10,500,000
Click Play to See Video
Example of Companies that Use
CTS Cooling Towers
https://maphub.net/coolingtowersystems/map
Sample of CTS Cooling Tower Locations in Operation in US
Thank you!
Joe Coates, Owner
478-737-4616
Dr. Dana Coates Eckman, CEO
559-676-2321
Office Number: 478-755-1905
All product information and literature is available on our website at
www.coolingtowersystems.com

More Related Content

Similar to Cooling Tower Systems

Coolinside DTC Liquid Cooling Solution.pdf
Coolinside DTC Liquid Cooling Solution.pdfCoolinside DTC Liquid Cooling Solution.pdf
Coolinside DTC Liquid Cooling Solution.pdfbui thequan
 
brochure_Kelvion_Polacel CMDR 2016-Eng
brochure_Kelvion_Polacel CMDR 2016-Engbrochure_Kelvion_Polacel CMDR 2016-Eng
brochure_Kelvion_Polacel CMDR 2016-EngGrégory Le Frene
 
Rittal Isı Değiştiricileri 104 129
Rittal Isı Değiştiricileri 104 129Rittal Isı Değiştiricileri 104 129
Rittal Isı Değiştiricileri 104 129erdinc klima
 
Gireesh product - heat exchanger
Gireesh product - heat exchangerGireesh product - heat exchanger
Gireesh product - heat exchangerGirishHHH
 
Gama power plant -- An overview (2018)
Gama power plant -- An overview (2018)Gama power plant -- An overview (2018)
Gama power plant -- An overview (2018)IndraneelBhattachary4
 
Chiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueChiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueTomas Eriksson
 
Kelvion afc product_line_brochure_en (1)
Kelvion afc product_line_brochure_en (1)Kelvion afc product_line_brochure_en (1)
Kelvion afc product_line_brochure_en (1)Roy Niekerk
 
brochure_Kelvion_Polacel CMDIF 2016-Eng
brochure_Kelvion_Polacel CMDIF 2016-Engbrochure_Kelvion_Polacel CMDIF 2016-Eng
brochure_Kelvion_Polacel CMDIF 2016-EngGrégory Le Frene
 
Service ariston depok 0813-8024-0365
Service ariston depok 0813-8024-0365Service ariston depok 0813-8024-0365
Service ariston depok 0813-8024-0365komporariston
 
Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...
Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...
Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...Juma Yousef J. Saleh جمعة يوسف جمعة صالح
 
Solarus Powercollectors Technical Brochure
Solarus Powercollectors Technical BrochureSolarus Powercollectors Technical Brochure
Solarus Powercollectors Technical BrochureAndy Varoshiotis
 

Similar to Cooling Tower Systems (20)

Coolinside DTC Liquid Cooling Solution.pdf
Coolinside DTC Liquid Cooling Solution.pdfCoolinside DTC Liquid Cooling Solution.pdf
Coolinside DTC Liquid Cooling Solution.pdf
 
brochure_Kelvion_Polacel CMDR 2016-Eng
brochure_Kelvion_Polacel CMDR 2016-Engbrochure_Kelvion_Polacel CMDR 2016-Eng
brochure_Kelvion_Polacel CMDR 2016-Eng
 
Breezair tbs580
Breezair tbs580 Breezair tbs580
Breezair tbs580
 
Rittal Isı Değiştiricileri 104 129
Rittal Isı Değiştiricileri 104 129Rittal Isı Değiştiricileri 104 129
Rittal Isı Değiştiricileri 104 129
 
Gireesh product - heat exchanger
Gireesh product - heat exchangerGireesh product - heat exchanger
Gireesh product - heat exchanger
 
Gama power plant -- An overview (2018)
Gama power plant -- An overview (2018)Gama power plant -- An overview (2018)
Gama power plant -- An overview (2018)
 
Chiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueChiller Plant-EN - Catalogue
Chiller Plant-EN - Catalogue
 
Chiller Plant-EN - Catalogue
Chiller Plant-EN - CatalogueChiller Plant-EN - Catalogue
Chiller Plant-EN - Catalogue
 
Kelvion afc product_line_brochure_en (1)
Kelvion afc product_line_brochure_en (1)Kelvion afc product_line_brochure_en (1)
Kelvion afc product_line_brochure_en (1)
 
brochure_Kelvion_Polacel CMDIF 2016-Eng
brochure_Kelvion_Polacel CMDIF 2016-Engbrochure_Kelvion_Polacel CMDIF 2016-Eng
brochure_Kelvion_Polacel CMDIF 2016-Eng
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Fidvi Refrigeration Corporate Profile
Fidvi Refrigeration Corporate ProfileFidvi Refrigeration Corporate Profile
Fidvi Refrigeration Corporate Profile
 
Service ariston depok 0813-8024-0365
Service ariston depok 0813-8024-0365Service ariston depok 0813-8024-0365
Service ariston depok 0813-8024-0365
 
Harga water heater ariston 081313462267
Harga water heater ariston 081313462267Harga water heater ariston 081313462267
Harga water heater ariston 081313462267
 
Cooling Tower Depot Capabilities Brochure
Cooling Tower Depot Capabilities BrochureCooling Tower Depot Capabilities Brochure
Cooling Tower Depot Capabilities Brochure
 
BE_YK_EngineeringGuide_G
BE_YK_EngineeringGuide_GBE_YK_EngineeringGuide_G
BE_YK_EngineeringGuide_G
 
FLYGT 3000 SERIES
FLYGT 3000 SERIESFLYGT 3000 SERIES
FLYGT 3000 SERIES
 
ATE Brochure
ATE BrochureATE Brochure
ATE Brochure
 
Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...
Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...
Module (s 203) fundamentals of cooling tower أساسيات ومبدأ عمل أبراج التبريد-...
 
Solarus Powercollectors Technical Brochure
Solarus Powercollectors Technical BrochureSolarus Powercollectors Technical Brochure
Solarus Powercollectors Technical Brochure
 

Recently uploaded

Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brandgvaughan
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLScyllaDB
 
Story boards and shot lists for my a level piece
Story boards and shot lists for my a level pieceStory boards and shot lists for my a level piece
Story boards and shot lists for my a level piececharlottematthew16
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Enterprise Knowledge
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebUiPathCommunity
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 3652toLead Limited
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...Fwdays
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clashcharlottematthew16
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationSafe Software
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 

Recently uploaded (20)

Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brand
 
Developer Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQLDeveloper Data Modeling Mistakes: From Postgres to NoSQL
Developer Data Modeling Mistakes: From Postgres to NoSQL
 
Story boards and shot lists for my a level piece
Story boards and shot lists for my a level pieceStory boards and shot lists for my a level piece
Story boards and shot lists for my a level piece
 
Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024Designing IA for AI - Information Architecture Conference 2024
Designing IA for AI - Information Architecture Conference 2024
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
Dev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio WebDev Dives: Streamline document processing with UiPath Studio Web
Dev Dives: Streamline document processing with UiPath Studio Web
 
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
Tech-Forward - Achieving Business Readiness For Copilot in Microsoft 365
 
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks..."LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
"LLMs for Python Engineers: Advanced Data Analysis and Semantic Kernel",Oleks...
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
Transcript: New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 
Powerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time ClashPowerpoint exploring the locations used in television show Time Clash
Powerpoint exploring the locations used in television show Time Clash
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
DMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special EditionDMCC Future of Trade Web3 - Special Edition
DMCC Future of Trade Web3 - Special Edition
 
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort ServiceHot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
Hot Sexy call girls in Panjabi Bagh 🔝 9953056974 🔝 Delhi escort Service
 
Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry InnovationBeyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
Beyond Boundaries: Leveraging No-Code Solutions for Industry Innovation
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 

Cooling Tower Systems

  • 2. Mission At CTS, we provide high quality customer service. We strive to create a culture of teamwork with positive communication to drive company innovation and ensure customers receive the most cost effective and energy efficient cooling towers, empowering their company to meet and exceed their desired thermal performance and production goals for your water-cooled equipment.
  • 3. Vision Our vision is to support all involved in the cooling tower industry to be proactive in selecting equipment that is cost effective and energy efficient to meet challenges faced in the field and in this everchanging world.
  • 4. CTS Customer Base and History ◦ Among our satisfied customers you will find OEM representatives (Other Equipment Manufacturers), industrial contractors, mechanical consulting and design engineers, chemical manufacturers, food and beverage manufacturers and processors, refrigeration warehouse companies, industrial buyers, utility companies, a large dry-cleaning market, etc. ◦ Cooling Tower Systems product line is within 74 countries with direct representation worldwide. ◦ Cooling Tower Systems is a manufacturer’s representative for cooling tower lines and related equipment for over 35 years. We have many different models of cooling towers in production, to include counter flow induced draft, counter flow crossflow, fluid cooling towers (closed loop system), high temperature cooling towers, industrial cooling towers, low noise cooling towers, etc. ◦ Our most common cooling tower we sell into the North and South America would be our counter flow induced draft, FRP (non-corrosive) cooling tower models, which is more energy efficient, cost effective, non-corrosive nature, and would be considered our most desirable model. ◦ CTS has been a member of the Cooling Tower Institute (CTI) since 1972 and rate our cooling towers per their specifications. We are CTI certified on our R-LC model line and will give a manufacturer CTI certification stating that all models of cooling towers that we select, using proper design conditions, will meet and exceed STD-201 CTI certification.
  • 5. Three Main Reasons to Buy A CTS Cooling Tower 1. Non-Corrosive Nature of Cooling Tower  The hot and cold deck are manufactured from PVC and FRP (Fiberglassed Reinforced Polyester). All steel components have a quality hot dip galvanizing that does resist corrosion. All fasteners on our cooling towers are 304 stainless steel in nature. We also have the capability of manufacturing all support components in 304 stainless steel. 2. Energy Efficiency  Our counterflow induced draft cooling towers allow us to be more energy efficient than a conventional tower. This is because it is a round circular type cooling tower with fresh intake from center of tower, 360 degrees around it. This allows an increase of fresh air supply verses a conventional cross-flow or counter-flow cooling tower, which only draws air from two sides of the system. Our counter flow induced cooling towers will use less fan motor horsepower when compared with other conventional style cooling towers. 3. Warranty ◦ Cooling Tower Systems, Inc. offers the best warranty in the industry, which is 20 years on the FRP (fiberglass reinforced polyester) components that are manufactured with a gel coating to protect it from ozone’s and UV lights. Our FRP is mixed with a gel coating that strengthens and protects it from the UV (ultraviolet) light rays in the ozone. This provides a higher resistance to rot and decay to all FRP portions of the cooling towers in extreme climate environments. ◦ The reason we can give a 20-year warranty verses others in the industry that give up to a 5 years warranty, is due to the FRP of tower to include the casing and cold-water basin. They have been gel coated during the manufacturing process, providing protection from UV ultraviolet ozone.
  • 6.
  • 7. Unique Features of a CTS Cooling Tower Quality ◦ Our cooling towers are non-rusting, FRP, counter flow, and induced draft. Its unique design allows water to recirculate and evaporate out the top of the tower. Our standard drift loss on T-2 models is approximately 0.1% of circulating water. CTS offers a Drift Eliminator Assembly that can decrease the loss of water to approximately 0.05%. The interior of this assembly has an S like structure so that water is not vaporized and then returned to the cooling tower. Maintenance ◦ Due to the round and constant motion of water in our cooling towers, this makes it very difficult for bacteria and mold to grow. Water is never stagnant in the cooling tower and is constantly being recirculated. ◦ We do have operation and service manual that needs to be reviewed and followed before a cooling tower is put into service. ◦ This information is available and downloadable from our website at www.coolingtowersystems.com
  • 8. Accessories Sold with CTS Cooling Towers Water Pumps: CTS has a quality line of water pumps, specially designed for our cooling towers. This product line allows users to maintain higher levels of efficiency over a wider range of operating conditions. Light weight and low noise. Suction and discharge connections are inline designed in the same size as towers to simplify piping in any direction for installation. All water pumps come with a TEFC motor for outdoor use. Immersion Heater: CTS has developed a full line of winterization kits. We provide both screw type heaters with thermostats and bottom mount heaters with control panels. These are installed in the basin of the cooling tower to protect them from freezing during the cold weather months. In cold climate using immersion heaters with an on and off thermostat control panel keeps the cold-water basin from freezing. Heat Exchanger: A system that combines a cooling tower with a plate heat exchanger, and you'll save money from day one. You'll also get a system that maintains effective fluid isolation and cools HVAC or process liquids more efficiently. A tower system with a heat exchanger is far less expensive to buy than any evaporative cooler. Couple the tower and the heat exchanger, and you also get a more efficient system that's cheaper to run, incorporates superior stainless-steel components, uses colder water (not glycol), and requires smaller components — including heat pumps — with lower horsepower. Storage Tank: Above ground, horizontal and vertical storage tanks are available for the purpose of storing water during the hot or cold weather months. Features tie-down slots, built-in graduation gallon-count indicators, siphon tube, offset fill-well and self-vented, slosh proof lids. Vertical storage tanks are most frequently used for nursing mobile application equipment and bulk storage. In a cold climate for winter use it is preferred not to use the cold-water basin for your processed water, instead elevate the cooling tower outside so after you get your desired thermal performance all the cooling towers processed water will flow inside into a remote processed water tank that is in a controlled atmosphere.
  • 9. T-2250 Single Cell System BTU/hr 3,750,000 T-3250 Multi-Cell System BTU/hr 18,750,000 T-3000 Multi-Cell System BTU/hr 15,000,000 CTS Cooling Towers T-2 Model T-23 (3 ton) up to T-2800 (800 ton) T-3 Model T-3000 (1000 ton) T-3250 (1250) T-3500 (1500 ton) CCT Model CCT-3 (3 ton) up to CCT-15 (15 ton) Special Order LLC Closed Circuit RLC CTI Certified
  • 10. CCT-237-10 10 Nominal Tons Based on Design Condition of 95/85/75 @ 30 GPM •This is 10 nominal ton cooling with sump pump and electrical switches installed and tested. •Equipped with a dual on/off switch - one for the motor and one for the sump pump •Wired and tested to low voltage, single phase electricity •Common uses include small process cooling, machinery cooling, and pond cooling applications.
  • 11. T-280 80 Nominal Tons Based on Design Condition of 95/85/75 @ 237 GPM BTU/hr 1,200,000
  • 12. T-2125 125 Nominal Tons Based on Design Condition of 95/85/75 @ 369 GPM BTU/hr 1,875,000
  • 13. T-2200 200 Nominal Tons Based on Design Condition of 95/85/75 @ 592 BTU/hr 3,000,000
  • 14. T-2500 500 Nominal Tons of Cooling Tower based on Design Condition of 95/85/75 @ 1,505 GPM BTU/hr 7,500,000
  • 15. T-3250 1,250 Nominal Tons Based on a Design Condition of 95/85/75 @ 3,761 GPM BTU/hr 18,750,000
  • 16. T-2700 Ontario, California 700 Nominal Tons Based on Design Condition of 95/85/75 @ 2,101 GPM BTU/hr 10,500,000 Click Play to See Video
  • 17. Example of Companies that Use CTS Cooling Towers
  • 18. https://maphub.net/coolingtowersystems/map Sample of CTS Cooling Tower Locations in Operation in US
  • 19. Thank you! Joe Coates, Owner 478-737-4616 Dr. Dana Coates Eckman, CEO 559-676-2321 Office Number: 478-755-1905 All product information and literature is available on our website at www.coolingtowersystems.com