SlideShare a Scribd company logo
1 of 6
OptoACTIVE
                                                     ™




              The System You’ve
                   Dreamed Of.
               Ultra Slim ANC Headphones for 95%
               MR EPI Noise Reduction in Real-Time




                                                         The Only Active Noise Control
                                                         Communications System for MRI


SOUND SOLUTIONS FROM LIGHT TECHNOLOGY
+
OptoACTIVE
                                 ™



Total Noise Control and Two-Way
Communications System for MRI
                                                     Passive
The Answer to Your Dreams.
OptoACTIVE™ provides the highest level of noise



                                                                    Active
reduction available in MRI-safe headphones, and is
the only communications system to use real-time
algorithmic, active harmonic noise cancelling, as
well as Optoacoustics’ proprietary passive noise
reduction techniques, to reduce 95 percent of MR
EPI main gradient resonance for the patient.                         Noise Control
OptoACTIVE Benefits:
   Safely cancels EPI main gradient noise
   Unsurpassed sound clarity                                                                                                           An
   Quiet two-way communication during
   a scan                                            Safely and effectively
                                                                                                                             Achievement
   Records sound as patient hears it                 reduces EPI noise by 60 dB                                                   in Quiet
   Self-calibrating with SPL monitoring in           (over 95%) without latency.
   real time
   Enables use of high fidelity audio stimuli        OptoACTIVE uses two complementary techniques to eliminate
                                                     EPI main gradient noise for the patient:
   Instant control over performance with
   digital touch display                                Optimal passive noise reduction with a revolutionary slim design,
                                                        resulting in unsurpassed sound clarity, wearer comfort and safety
   Concurrent multiple audio inputs,
                                                        Real-time algorithmic, out-of-phase harmonic active noise cancelling using
   including TTL                                        our proprietary DSP
   Certified EMI/RFI immunity                        The System reduces gradient noise so effectively that we’ve even added Waves® MaxxAudio digital sound
                                                     enhancement. Voice and high-fidelity audio has never sounded better in MRI.
Engineering that
                                     Rivals Magic
Ultra-slim OptoACTIVE headphones are
designed for advanced 20- or 32-channel




                                                         +
coils used in 3T and 7T fMRI.
OptoACTIVE provides the slimmest and most sensitive
headphones available today for use in MRI, with a
frequency response range of 50-20,000 Hz.
Built-in optical microphones enable automatic



                                                        Slim
self-calibration, SPL monitoring and real-time in-ear
stereo sound recording.
With its proprietary DSP and predictive behavior
algorithms, OptoACTIVE sets the standard for robust,
dependable active noise control in a wide variety of
applications and settings, regardless of the MRI
platform.




                                                          Robust                         Ideal for the study of:
                                                                                       Sleeping disorders, autism, children
                                                          Engineering                 suffering from claustrophobia,
                                                                                     auditory fMRI and many other new
                                                                                     research areas that were previously
                                                                                   impractical or unattainable.
                                                                 OptoACTIVE is used in the world’s leading MR research
                                                                facilities, and comes bundled with our industry-leading
                                                               FOMRI-III™ noise cancelling microphone.
+
                                            Self-Calibrates in
                                             Less Than 20 Seconds

           Smart
                                    Simple
                                    Operation                       LCD touch-screen
                                                                    control console displays noise
                                                                    exposure, stimuli levels and spectrum
OptoACTIVE matches innovation with operating simplicity,
enabling you to focus entirely on the research at hand.
                                                                    analysis in real time.
The system is completely self-calibrating, session-by-session,
Patient-by-Patient. A short sequence of screen taps tells                      At every moment, the technician can access all basic
OptoACTIVE to calibrate its advanced noise cancelling                          noise cancelling, advanced attenuation and channel
algorithms for a scan – an operation that takes 16 seconds and                 selection. OptoACTIVE uses a hybrid LCD digital touch
requires no specialized knowledge or operator intervention.                    and pushbutton console that intuitively controls:
Embedded DSP algorithms are optimized for the challenging                         Initial and ongoing calibrations
acoustic characteristics of MRI, including resonance frequencies,                 Real time noise cancelling
dynamic range and varying duty-cycle time events.
                                                                                  Channel level volume and recording
Our bundled OptiMRI software enables concurrent recording of
                                                                                  Music mixing with left/right gain control
built-in left and right channel microphone outputs, filtered
speech processed by the DSP, and up to three synchronized TTL                     Full duplex in-line PTT communications
events. A complete set of output post-processing capabilities is                  FOMRI-III noise-cancelling microphone
also provided.
System Accessories
The Challenge of EPI Sequence Noise in MRI                                                                              OptoACTIVE accessories enable the highest possible system
                                                                                                                        performance and operating throughput.
EPI sequences used in fMRI are the loudest in
MR imaging, sometimes exceeding 120 dB in a             MAIN EPI NOISE AT 117 dB SPL (RED)

3T scanner. That equates to the noise intensity                                                                         Quiet 2-Way
of a jet engine at takeoff. Even more challenging      PASSIVE ATTENUATION (GREEN)                                      Communication
for engineers than the intensity of MRI noise are                                                                       with FOMRI-III™
                                                                                                   60 dB
the noise transients and harmonics that are                                                                             Microphone
generated at up to several KHz during various                                                                           The gold-standard for high quality
fMRI duty cycles, and which exhibit endless                                                                             MRI speech recording and operating
patterns of variation.                                                                                                  simplicity comes bundled with
                                                        ACTIVE + PASSIVE ATTENUATION (BLUE)
To solve this, Optoacoustics has developed and                                                                          OptoACTIVE headphones.
implemented a tailor-made, selective digital                                                                            The FOMRI-III noise cancelling
algorithm which actively attenuates EPI gradient                                                                        microphone can be mounted
noise in all its forms. Our proprietary real-time   Frequency domain graph showing full                                 securely on any sized head coil,            Hear precisely
                                                                                                                        using our instant strap-on              what is said inside
method drives the same noise created by the         60 dB attenuation (95%) of the main EPI                             gooseneck boom.
                                                                                                                                                                     the bore, and
MR machine out of phase, then feeds it back         resonance, resulting from combined                                  Completely safe, this ultra-flexible
into the patient’s headphones. When both real                                                                                                                  synchronize speech
                                                    passive and active noise cancellation.                              mount enables extremely close             to TTL signals in
and out-of-phase sounds are superimposed, true                                                                          voice proximity and filtered
                                                                                                                                                                         real time.
noise cancellation is achieved.                                                                                         recording with low latency.

                                                                                                                            Crisp, clear speech in real time
                                                                                                                            Selectable, automatic noise reduction
                        MR SUITE          CONTROL ROOM
                                                                                                                            Synchronize speech with up to 3 TTL signals
  OptoACTIVE Headphones
                ™

                                                                DSP +                                                       Monitor, record and broadcast filtered speech
  in RF Head Coil
                                                                Electro-                                                    Plug-and-play operation
                                                                Optical                                                     Strap-on microphone mounting on your RF coil
                                                                Unit                     The OptoACTIVE system is
                             Fiber Optic Cable
                                   15 m                                                  a product of more than a
                                                                                         decade of acoustics
                                                        RS-232 Cable
                                                                                         research, MRI applied          OptoVAC Vacuum
                                                                                         engineering, and close         Enhancer
                                                                                         partnering with leading
                                                                Two-Way                  MRI research facilities.       Easily attaches to headphones
 Ultra-Slim                                                     Control                                                 to improve active noise
 Headphones               10 mm                                 Console                  OptoACTIVE components          cancelling performance by an
                          width                                                          are installed in both the MR   additional 10 dB.
                          compressed
                                                                                         Suite and the Control Room.
OptoACTIVE™ SYSTEM SPECIFICATIONS                                                 OptoACTIVE Control Console                                                                                               FOMRI-III™ Optical Microphone
                                                                                                                                                                                                             Our FOMRI-III microphone brings unprecedented clear speech to
OptoACTIVE Slim Optical ANC Headphones                                                         POWER                               USB OUT       BALANCE         PROGRAM       BALANCE
                                                                                                                                                                                                             MRI and enables high quality two-way communications.
                                                                                                                                                        LINE 2                       LINE 1




  Frequency Response                              50-15,000 Hz
                                                                                                                                             L               R
                                                                                                                                                                                                             Configuration Type                   Dual channel, perpendicular
  Maximum Sound Pressure Level                    104 dB SPL                                                                                                               L             R


                                                                                                                                                                                                             Frequency Response                   50-20,000 Hz
  Total Harmonic Distortion                       < 1 % at 1 Pa
                                                                                                                                                                                                             Max. Sound Pressure Level (SPL)      130 dB SPL
  Passive Noise Attenuation                       25 dB                                        LINE 1     ANALOG       MIC IN     EARPHONE         -    +            DIGITAL             RESET
                                                                                                                                                 +12 Vdc (1A)                                                Total Harmonic Distortion            < 1% at 94 dB SPL
  Active Noise Cancellation                       > 20 dB SPL (> 90 %)                                       OPTOACOUSTICS LTD.
                                                                                                                                                                           OPTICAL IN
                                                                                                             MODEL: OptoACTIVE                                               LINE 2
                                                                                                                                                                                                             Operating Temperature                0 to +60 °C (32 to +140 °F)
  EPI Main Resonance Attenuation                  > 50 dB (> 99%)                                            SN:



  Total Noise Attenuation                         > 40 dB SPL (> 99 %)
                                                                                                                                                                                                           FOMRI-III Subcomponents
  DSP Latency                                     0 msec, Real-time
                                                                                                                                                                                                             Microphone Housing                   Polycarbonate
  Headphones Base Material                        Polyurethane                        Features:         (1) PTT Speak to Patient (Using Built-in Microphone)
                                                                                                                                                                                                               Head Dimensions                    60/20/25 mm [L/W/H]
  Maximum Headphone Thickness                     10 mm                                                 (2) Self-Hearing Volume Control
                                                                                                                                                                                                               Head Weight                        160 g
  Optical Fiber Cable (MIL STD)                                                                         (4) External Audio Volume Control
                                                                                                                                                                                                             Mounting Attachment Box              Polycarbonate
     Cable Coating Material                       Polyester Elastomer
                                                                                                                                                                                                               Box Dimensions                     60/60/25 mm [L/W/H]
     Cable Dimensions 15 m [L], 5 mm [D]                                              Dimensions                                                        105/165/220 mm [H/D/W]
                                                                                                                                                                                                               Mounting Mechanism                 Velcro® Strips
     Cable Connector                              4 x ST                              Weight                                                            1.2 Kg
                                                                                                                                                                                                             3D Adjustable Boom                   Polypropylene
                                                                                      Power                                                             12-15 V DC
OptoACTIVE Electro-Optical Unit (EOU)                                                                                                                                                                          Boom Dimensions                    300/16 mm [L/D]
                                                                                      Input Connectors
                                                                                                                                                                                                             Optical Fiber Cable (MIL STD)
  Box Dimensions                            44 / 46 / 21.1 cm [H/D/W]                    Optical                                                        8 x ST (Main, Reference)
                                                                                                                                                                                                               Coating Material                   Polyester Elastomer
  Weight                                    6 kg (13.3 lb)                                                                                              SPDIF (for external audio)
                                                                                                                                                                                                               Cable Dimensions                   15 m [L], 5 mm [D]
  Power                                     110 V / 220 V DC 2A                          Power                                                          3.5 mm
                                                                                                                                                                                                               Connector                          4 x ST
  Operating Temperature                     0 to +40 °C (32 to +104 °F)                  TTL                                                            3 x BNC
                                                                                                                                                                                                             Pop Screen (Disposable)              Polycarbonate, Polyester
                                                                                         DSP (for algorithm updates)                                    1 x USB
                                                                                      Output Connectors (for Built-in Mic)
OptoACTIVE™ is a component of Optoacoustics’ MRI Multi-Channel Optical                                                                                                                                     FOMRI-III OptiMRI Software
                                                                                         Analog (Main, Ref, DSP)                                        3 x RCA (100 mV/Pa)
Communication (MOC) System which has been granted approval as a US FDA                                                                                                                                       Sampling Frequency
510(k) device.                                                                           Digital (Main/Ref, DSP/TTL)                                    2 x USB, SPDIF
                                                                                                                                                                                                               OptiMRI 3.1 (DSP)                  8,000/16,000 Hz, 16 Bit
A portion of the ANC algorithm used in OptoACTIVE is licensed from the MRC            Noise Reduction (for Built-in Mic)                                Low/Med/High (15-40 dB)
                                                                                                                                                                                                             Latency
Institute of Hearing Research (IHR) at Nottingham, UK.                                Loudspeaker (Built-in)
                                                                                                                                                                                                               OptiMRI 3.1 (DSP)                  12 msec
                                                                                         Frequency Response                                             100-10,000 Hz
                                                                                         Gain Knob RangeUp to +45 dB



                                                            www.optoacoustics.com/optoactive                                                                                                     Optoacoustics is a leading manufacturer of high performance, optical
                                                                                                                                                                                                 fiber-based sound and vibration sensors. Each of our products combines
                                                            PHONE +1 866-867-5029 US Toll Free                          HEADQUARTERS                                                             the natural intelligence of optics and acoustics to meet technical
                                                                  +972 3-634-4488                                       17 Hanotea Street                                                        performance demands which cannot be addressed by conventional
                                                                                                                        73160 Mazor                                                              sensing solutions. Optoacoustics’ pioneering technology is protected by
                                                            FAX   +972 3-634-9292                                       Israel
                                                            EMAIL info@optoacoustics.com                                                                                                         over 20 international patents.
                                                            Copyright © 2012 Optoacoustics Ltd. All rights reserved. The information appearing here is subject to change without notice. Unless otherwise indicated, all product names are trademarks
    SOUND SOLUTIONS FROM LIGHT TECHNOLOGY                   of Optoacoustics Ltd.                                                                                                                                                  BR-ACTIVE-1 0912

More Related Content

What's hot

Polycom Video Communications
Polycom Video CommunicationsPolycom Video Communications
Polycom Video CommunicationsVideoguy
 
BohanTech CCTV Camera Price List
BohanTech CCTV Camera Price ListBohanTech CCTV Camera Price List
BohanTech CCTV Camera Price ListBohanTech
 
BRC-H900P
BRC-H900PBRC-H900P
BRC-H900PAVNed
 
Integrated smart surveillance systems for rail-based mass transportation
Integrated smart surveillance systems for rail-based mass transportationIntegrated smart surveillance systems for rail-based mass transportation
Integrated smart surveillance systems for rail-based mass transportationFrancesco Flammini
 
Cooled 640x480 15um MWIR Thermal Infrared| FLIR MWIR Thermal Imaging Laser ...
Cooled 640x480 15um MWIR Thermal Infrared|  FLIR MWIR Thermal Imaging  Laser ...Cooled 640x480 15um MWIR Thermal Infrared|  FLIR MWIR Thermal Imaging  Laser ...
Cooled 640x480 15um MWIR Thermal Infrared| FLIR MWIR Thermal Imaging Laser ...Tim Troxel
 
5 Megapixel IP camera
5 Megapixel IP camera5 Megapixel IP camera
5 Megapixel IP cameraJos Reterink
 
Catalogoprojectos steinel
Catalogoprojectos steinelCatalogoprojectos steinel
Catalogoprojectos steinelMiguel Silva
 

What's hot (14)

FLIR T 640 IR Camera
FLIR T 640 IR CameraFLIR T 640 IR Camera
FLIR T 640 IR Camera
 
Polycom Video Communications
Polycom Video CommunicationsPolycom Video Communications
Polycom Video Communications
 
Mx pf d24_en_111104
Mx pf d24_en_111104Mx pf d24_en_111104
Mx pf d24_en_111104
 
Fluke TiR32
Fluke TiR32 Fluke TiR32
Fluke TiR32
 
BohanTech CCTV Camera Price List
BohanTech CCTV Camera Price ListBohanTech CCTV Camera Price List
BohanTech CCTV Camera Price List
 
BRC-H900P
BRC-H900PBRC-H900P
BRC-H900P
 
Sony BRC-Z700
Sony BRC-Z700Sony BRC-Z700
Sony BRC-Z700
 
Sncep520 sip2113 f
Sncep520 sip2113 fSncep520 sip2113 f
Sncep520 sip2113 f
 
Integrated smart surveillance systems for rail-based mass transportation
Integrated smart surveillance systems for rail-based mass transportationIntegrated smart surveillance systems for rail-based mass transportation
Integrated smart surveillance systems for rail-based mass transportation
 
Ppt 新
Ppt 新Ppt 新
Ppt 新
 
Ihear
IhearIhear
Ihear
 
Cooled 640x480 15um MWIR Thermal Infrared| FLIR MWIR Thermal Imaging Laser ...
Cooled 640x480 15um MWIR Thermal Infrared|  FLIR MWIR Thermal Imaging  Laser ...Cooled 640x480 15um MWIR Thermal Infrared|  FLIR MWIR Thermal Imaging  Laser ...
Cooled 640x480 15um MWIR Thermal Infrared| FLIR MWIR Thermal Imaging Laser ...
 
5 Megapixel IP camera
5 Megapixel IP camera5 Megapixel IP camera
5 Megapixel IP camera
 
Catalogoprojectos steinel
Catalogoprojectos steinelCatalogoprojectos steinel
Catalogoprojectos steinel
 

Similar to OptoActive MRI Headphones

Audio technica atcs-60 brochure
Audio technica atcs-60 brochureAudio technica atcs-60 brochure
Audio technica atcs-60 brochureRadikal Ltd.
 
PHOENIX AUDIO TECHNOLOGIES - A large Audio Signal Algorithm Portfolio
PHOENIX AUDIO TECHNOLOGIES  - A large Audio Signal Algorithm PortfolioPHOENIX AUDIO TECHNOLOGIES  - A large Audio Signal Algorithm Portfolio
PHOENIX AUDIO TECHNOLOGIES - A large Audio Signal Algorithm PortfolioHTCS LLC
 
Lecture 8 audio compression
Lecture 8 audio compressionLecture 8 audio compression
Lecture 8 audio compressionMr SMAK
 
Lecture 8 audio compression
Lecture 8 audio compressionLecture 8 audio compression
Lecture 8 audio compressionMr SMAK
 
A review of Noise Suppression Technology for Real-Time Speech Enhancement
A review of Noise Suppression Technology for Real-Time Speech EnhancementA review of Noise Suppression Technology for Real-Time Speech Enhancement
A review of Noise Suppression Technology for Real-Time Speech EnhancementIRJET Journal
 
The general directions of GritTec's researches
The general directions of GritTec's researchesThe general directions of GritTec's researches
The general directions of GritTec's researchesGritTec Ltd.
 
MyLab Alpha brochure
MyLab Alpha brochureMyLab Alpha brochure
MyLab Alpha brochureMIDEAS
 
Specific features of hearing aids
Specific features of hearing aidsSpecific features of hearing aids
Specific features of hearing aidsPra_buddha
 
Dukane 8916 H
Dukane 8916 HDukane 8916 H
Dukane 8916 HMEAV
 
HXR-NX5E
HXR-NX5EHXR-NX5E
HXR-NX5EAVNed
 
29.skinput technology
29.skinput technology29.skinput technology
29.skinput technologyNaga Dinesh
 
MyRay_Hyperion+X5+Panoramic+Imager
MyRay_Hyperion+X5+Panoramic+ImagerMyRay_Hyperion+X5+Panoramic+Imager
MyRay_Hyperion+X5+Panoramic+ImagerDavid Medimurac
 
Silent sound technology final report
Silent sound technology final reportSilent sound technology final report
Silent sound technology final reportLohit Dalal
 
Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...
Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...
Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...Plantronics Europe and Africa
 
Coordinated Adaptive Processing.pdf
Coordinated Adaptive Processing.pdfCoordinated Adaptive Processing.pdf
Coordinated Adaptive Processing.pdfMaiGaber4
 

Similar to OptoActive MRI Headphones (20)

Audio technica atcs-60 brochure
Audio technica atcs-60 brochureAudio technica atcs-60 brochure
Audio technica atcs-60 brochure
 
PHOENIX AUDIO TECHNOLOGIES - A large Audio Signal Algorithm Portfolio
PHOENIX AUDIO TECHNOLOGIES  - A large Audio Signal Algorithm PortfolioPHOENIX AUDIO TECHNOLOGIES  - A large Audio Signal Algorithm Portfolio
PHOENIX AUDIO TECHNOLOGIES - A large Audio Signal Algorithm Portfolio
 
Lecture 8 audio compression
Lecture 8 audio compressionLecture 8 audio compression
Lecture 8 audio compression
 
Lecture 8 audio compression
Lecture 8 audio compressionLecture 8 audio compression
Lecture 8 audio compression
 
Passion™440
Passion™440Passion™440
Passion™440
 
A review of Noise Suppression Technology for Real-Time Speech Enhancement
A review of Noise Suppression Technology for Real-Time Speech EnhancementA review of Noise Suppression Technology for Real-Time Speech Enhancement
A review of Noise Suppression Technology for Real-Time Speech Enhancement
 
N
NN
N
 
brochure
brochurebrochure
brochure
 
The general directions of GritTec's researches
The general directions of GritTec's researchesThe general directions of GritTec's researches
The general directions of GritTec's researches
 
Sony VPL-MX25
Sony VPL-MX25Sony VPL-MX25
Sony VPL-MX25
 
MyLab Alpha brochure
MyLab Alpha brochureMyLab Alpha brochure
MyLab Alpha brochure
 
Specific features of hearing aids
Specific features of hearing aidsSpecific features of hearing aids
Specific features of hearing aids
 
Silent Sound Technology
Silent Sound TechnologySilent Sound Technology
Silent Sound Technology
 
Dukane 8916 H
Dukane 8916 HDukane 8916 H
Dukane 8916 H
 
HXR-NX5E
HXR-NX5EHXR-NX5E
HXR-NX5E
 
29.skinput technology
29.skinput technology29.skinput technology
29.skinput technology
 
MyRay_Hyperion+X5+Panoramic+Imager
MyRay_Hyperion+X5+Panoramic+ImagerMyRay_Hyperion+X5+Panoramic+Imager
MyRay_Hyperion+X5+Panoramic+Imager
 
Silent sound technology final report
Silent sound technology final reportSilent sound technology final report
Silent sound technology final report
 
Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...
Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...
Boost your Workforce Productivity by Adopting the Acoustic Intelligence Frame...
 
Coordinated Adaptive Processing.pdf
Coordinated Adaptive Processing.pdfCoordinated Adaptive Processing.pdf
Coordinated Adaptive Processing.pdf
 

OptoActive MRI Headphones

  • 1. OptoACTIVE ™ The System You’ve Dreamed Of. Ultra Slim ANC Headphones for 95% MR EPI Noise Reduction in Real-Time The Only Active Noise Control Communications System for MRI SOUND SOLUTIONS FROM LIGHT TECHNOLOGY
  • 2. + OptoACTIVE ™ Total Noise Control and Two-Way Communications System for MRI Passive The Answer to Your Dreams. OptoACTIVE™ provides the highest level of noise Active reduction available in MRI-safe headphones, and is the only communications system to use real-time algorithmic, active harmonic noise cancelling, as well as Optoacoustics’ proprietary passive noise reduction techniques, to reduce 95 percent of MR EPI main gradient resonance for the patient. Noise Control OptoACTIVE Benefits: Safely cancels EPI main gradient noise Unsurpassed sound clarity An Quiet two-way communication during a scan Safely and effectively Achievement Records sound as patient hears it reduces EPI noise by 60 dB in Quiet Self-calibrating with SPL monitoring in (over 95%) without latency. real time Enables use of high fidelity audio stimuli OptoACTIVE uses two complementary techniques to eliminate EPI main gradient noise for the patient: Instant control over performance with digital touch display Optimal passive noise reduction with a revolutionary slim design, resulting in unsurpassed sound clarity, wearer comfort and safety Concurrent multiple audio inputs, Real-time algorithmic, out-of-phase harmonic active noise cancelling using including TTL our proprietary DSP Certified EMI/RFI immunity The System reduces gradient noise so effectively that we’ve even added Waves® MaxxAudio digital sound enhancement. Voice and high-fidelity audio has never sounded better in MRI.
  • 3. Engineering that Rivals Magic Ultra-slim OptoACTIVE headphones are designed for advanced 20- or 32-channel + coils used in 3T and 7T fMRI. OptoACTIVE provides the slimmest and most sensitive headphones available today for use in MRI, with a frequency response range of 50-20,000 Hz. Built-in optical microphones enable automatic Slim self-calibration, SPL monitoring and real-time in-ear stereo sound recording. With its proprietary DSP and predictive behavior algorithms, OptoACTIVE sets the standard for robust, dependable active noise control in a wide variety of applications and settings, regardless of the MRI platform. Robust Ideal for the study of: Sleeping disorders, autism, children Engineering suffering from claustrophobia, auditory fMRI and many other new research areas that were previously impractical or unattainable. OptoACTIVE is used in the world’s leading MR research facilities, and comes bundled with our industry-leading FOMRI-III™ noise cancelling microphone.
  • 4. + Self-Calibrates in Less Than 20 Seconds Smart Simple Operation LCD touch-screen control console displays noise exposure, stimuli levels and spectrum OptoACTIVE matches innovation with operating simplicity, enabling you to focus entirely on the research at hand. analysis in real time. The system is completely self-calibrating, session-by-session, Patient-by-Patient. A short sequence of screen taps tells At every moment, the technician can access all basic OptoACTIVE to calibrate its advanced noise cancelling noise cancelling, advanced attenuation and channel algorithms for a scan – an operation that takes 16 seconds and selection. OptoACTIVE uses a hybrid LCD digital touch requires no specialized knowledge or operator intervention. and pushbutton console that intuitively controls: Embedded DSP algorithms are optimized for the challenging Initial and ongoing calibrations acoustic characteristics of MRI, including resonance frequencies, Real time noise cancelling dynamic range and varying duty-cycle time events. Channel level volume and recording Our bundled OptiMRI software enables concurrent recording of Music mixing with left/right gain control built-in left and right channel microphone outputs, filtered speech processed by the DSP, and up to three synchronized TTL Full duplex in-line PTT communications events. A complete set of output post-processing capabilities is FOMRI-III noise-cancelling microphone also provided.
  • 5. System Accessories The Challenge of EPI Sequence Noise in MRI OptoACTIVE accessories enable the highest possible system performance and operating throughput. EPI sequences used in fMRI are the loudest in MR imaging, sometimes exceeding 120 dB in a MAIN EPI NOISE AT 117 dB SPL (RED) 3T scanner. That equates to the noise intensity Quiet 2-Way of a jet engine at takeoff. Even more challenging PASSIVE ATTENUATION (GREEN) Communication for engineers than the intensity of MRI noise are with FOMRI-III™ 60 dB the noise transients and harmonics that are Microphone generated at up to several KHz during various The gold-standard for high quality fMRI duty cycles, and which exhibit endless MRI speech recording and operating patterns of variation. simplicity comes bundled with ACTIVE + PASSIVE ATTENUATION (BLUE) To solve this, Optoacoustics has developed and OptoACTIVE headphones. implemented a tailor-made, selective digital The FOMRI-III noise cancelling algorithm which actively attenuates EPI gradient microphone can be mounted noise in all its forms. Our proprietary real-time Frequency domain graph showing full securely on any sized head coil, Hear precisely using our instant strap-on what is said inside method drives the same noise created by the 60 dB attenuation (95%) of the main EPI gooseneck boom. the bore, and MR machine out of phase, then feeds it back resonance, resulting from combined Completely safe, this ultra-flexible into the patient’s headphones. When both real synchronize speech passive and active noise cancellation. mount enables extremely close to TTL signals in and out-of-phase sounds are superimposed, true voice proximity and filtered real time. noise cancellation is achieved. recording with low latency. Crisp, clear speech in real time Selectable, automatic noise reduction MR SUITE CONTROL ROOM Synchronize speech with up to 3 TTL signals OptoACTIVE Headphones ™ DSP + Monitor, record and broadcast filtered speech in RF Head Coil Electro- Plug-and-play operation Optical Strap-on microphone mounting on your RF coil Unit The OptoACTIVE system is Fiber Optic Cable 15 m a product of more than a decade of acoustics RS-232 Cable research, MRI applied OptoVAC Vacuum engineering, and close Enhancer partnering with leading Two-Way MRI research facilities. Easily attaches to headphones Ultra-Slim Control to improve active noise Headphones 10 mm Console OptoACTIVE components cancelling performance by an width are installed in both the MR additional 10 dB. compressed Suite and the Control Room.
  • 6. OptoACTIVE™ SYSTEM SPECIFICATIONS OptoACTIVE Control Console FOMRI-III™ Optical Microphone Our FOMRI-III microphone brings unprecedented clear speech to OptoACTIVE Slim Optical ANC Headphones POWER USB OUT BALANCE PROGRAM BALANCE MRI and enables high quality two-way communications. LINE 2 LINE 1 Frequency Response 50-15,000 Hz L R Configuration Type Dual channel, perpendicular Maximum Sound Pressure Level 104 dB SPL L R Frequency Response 50-20,000 Hz Total Harmonic Distortion < 1 % at 1 Pa Max. Sound Pressure Level (SPL) 130 dB SPL Passive Noise Attenuation 25 dB LINE 1 ANALOG MIC IN EARPHONE - + DIGITAL RESET +12 Vdc (1A) Total Harmonic Distortion < 1% at 94 dB SPL Active Noise Cancellation > 20 dB SPL (> 90 %) OPTOACOUSTICS LTD. OPTICAL IN MODEL: OptoACTIVE LINE 2 Operating Temperature 0 to +60 °C (32 to +140 °F) EPI Main Resonance Attenuation > 50 dB (> 99%) SN: Total Noise Attenuation > 40 dB SPL (> 99 %) FOMRI-III Subcomponents DSP Latency 0 msec, Real-time Microphone Housing Polycarbonate Headphones Base Material Polyurethane Features: (1) PTT Speak to Patient (Using Built-in Microphone) Head Dimensions 60/20/25 mm [L/W/H] Maximum Headphone Thickness 10 mm (2) Self-Hearing Volume Control Head Weight 160 g Optical Fiber Cable (MIL STD) (4) External Audio Volume Control Mounting Attachment Box Polycarbonate Cable Coating Material Polyester Elastomer Box Dimensions 60/60/25 mm [L/W/H] Cable Dimensions 15 m [L], 5 mm [D] Dimensions 105/165/220 mm [H/D/W] Mounting Mechanism Velcro® Strips Cable Connector 4 x ST Weight 1.2 Kg 3D Adjustable Boom Polypropylene Power 12-15 V DC OptoACTIVE Electro-Optical Unit (EOU) Boom Dimensions 300/16 mm [L/D] Input Connectors Optical Fiber Cable (MIL STD) Box Dimensions 44 / 46 / 21.1 cm [H/D/W] Optical 8 x ST (Main, Reference) Coating Material Polyester Elastomer Weight 6 kg (13.3 lb) SPDIF (for external audio) Cable Dimensions 15 m [L], 5 mm [D] Power 110 V / 220 V DC 2A Power 3.5 mm Connector 4 x ST Operating Temperature 0 to +40 °C (32 to +104 °F) TTL 3 x BNC Pop Screen (Disposable) Polycarbonate, Polyester DSP (for algorithm updates) 1 x USB Output Connectors (for Built-in Mic) OptoACTIVE™ is a component of Optoacoustics’ MRI Multi-Channel Optical FOMRI-III OptiMRI Software Analog (Main, Ref, DSP) 3 x RCA (100 mV/Pa) Communication (MOC) System which has been granted approval as a US FDA Sampling Frequency 510(k) device. Digital (Main/Ref, DSP/TTL) 2 x USB, SPDIF OptiMRI 3.1 (DSP) 8,000/16,000 Hz, 16 Bit A portion of the ANC algorithm used in OptoACTIVE is licensed from the MRC Noise Reduction (for Built-in Mic) Low/Med/High (15-40 dB) Latency Institute of Hearing Research (IHR) at Nottingham, UK. Loudspeaker (Built-in) OptiMRI 3.1 (DSP) 12 msec Frequency Response 100-10,000 Hz Gain Knob RangeUp to +45 dB www.optoacoustics.com/optoactive Optoacoustics is a leading manufacturer of high performance, optical fiber-based sound and vibration sensors. Each of our products combines PHONE +1 866-867-5029 US Toll Free HEADQUARTERS the natural intelligence of optics and acoustics to meet technical +972 3-634-4488 17 Hanotea Street performance demands which cannot be addressed by conventional 73160 Mazor sensing solutions. Optoacoustics’ pioneering technology is protected by FAX +972 3-634-9292 Israel EMAIL info@optoacoustics.com over 20 international patents. Copyright © 2012 Optoacoustics Ltd. All rights reserved. The information appearing here is subject to change without notice. Unless otherwise indicated, all product names are trademarks SOUND SOLUTIONS FROM LIGHT TECHNOLOGY of Optoacoustics Ltd. BR-ACTIVE-1 0912