Draka Offshore Cables British Standard / UKOOA Program

1,168 views

Published on

As a successful international cable manufacturer nobody knows more about cable than Draka. Through a continual programme of research and development, Draka lead the way with a world beating range of premium quality cables that meet and often exceed British Standards and are fully BASEC approved.

Draka is a major supplier to the construction industry, with a complete range of housewiring and low voltage supply cables, for use in domestic premises, commercial office developments and public buildings, such as retail business parks, hospitals and sports complexes. In addition to this general range of energy cables, the company is a market leader in the production of fire retardant cables and addresses the needs of a host of specific, individual markets and applications.

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,168
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Draka Offshore Cables British Standard / UKOOA Program

  1. 1. Marine, Oil & GasBRITISH STANDARD / UKOOA
  2. 2. Offshore CablesBritish Standard / UKOOAProgramIndexFlame retardant halogen-free earthing cable with enhanced oil resistance RU 0.6/1 kv…………..………………………………………………....…………………………………………...2Flame retardant halogen-free unarmoured power cable with enhanced oil resistance RU 0.6/1 kv…………………………………………………………….…………………………….4Flame retardant halogen-free armoured power cable with enhanced oil resistance RFCU 0.6/1 kv……..…………………………….……………………….…….………………….6Flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance RFCU(C) 250v — Collective Screen…………….....................10Flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance RFCU(I) 250v — Individual Screen……………….....................14Fire resistant, flame retardant halogen-free armoured power cable with enhanced oil resistance BFCU 0.6/1 kv …………………….…....…..……….…………………...18Fire resistant, flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance BFCU(C) 250v — Collective Screen….......22Fire resistant, flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance BFCU(I) 250v — Individual Screen………..…26UKOOA Coding System……………………………………………………………………………………………………………………………………………………………………………………………………………….…….31Technical InformationConductor resistance………………………………………………………………………………………………………………………………………………………………………………………………………..32Installation recommendations…………………………………………………………………………………………………………………………………………………………………………………………..33Voltage tests after installation………………………………………………………………………………………………………………………………………………………………………………………….34Volt drop (RFCU power cable)……………………………………………………………………………………………………………………………………………………………………………………………35Volt drop (BFCU power cable)……………………………………………………………………………………………………………………………………………………………………………………………36Cable code designation……………………………………………………………………………………………………………………………………………………………………………………………………...371www.drakaMOG.comInformation subject to change without noticeMarine, Oil & Gas
  3. 3. RU 0.6/1KV Earthing cableFlame retardant halogen-free earthing cable.Enhanced oil-resistance.RU 0.6/1kVOperating temperature : 90°COperating Voltage : 0.6/1kVUnarmoured cable for fixed installation for earthingpurposes in safe areas.Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS6883 - DesignBS6360 class 2 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 - Flame RetardantIEC60332-3-22 - Flame retardantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low SmokeCodeLetterConductor Tinned stranded circular copper, BS6360, class 2Insulation R EP-rubber, GP4 to BS7655:section 1.2Inner sheath No inner sheath, additional tapes may be appliedArmour/screen No armourOuter sheath UFlame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF)SW4 to BS7655 section 2.6. (Mud resistant version available on request)Marking text"metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number ofcores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cableactually supplied)Outer sheathcolourGreen/YellowCore identificationSingle core - off white2Constructionwww.drakaMOG.comInformation subject to change without noticeMarine, Oil & Gas
  4. 4. RU 0.6/1KV Earthing cableMarine, Oil & GasPart number Description Sheath Colour Design standard840080 RU 0.6/1kV 1X 6mm² YELLOW/GREEN BS 6883:1999840081 RU 0.6/1kV 1X 16mm² YELLOW/GREEN BS 6883:1999840082 RU 0.6/1kV 1X 25mm² YELLOW/GREEN BS 6883:1999840083 RU 0.6/1kV 1X 35mm² YELLOW/GREEN BS 6883:1999840084 RU 0.6/1kV 1X 70mm² YELLOW/GREEN BS 6883:1999Number ofcoresCross sectioncore, mm²ConductorDiameter, mmInsulationThickness, mmThicknessOuter Sheath,mmApprox OverallDiameter, mmApprox Weightof Cable(Kg/Km)Copper contentApprox.(Kg/Km)1 6 3.15 1.0 1 7.5 115 551 16 5.15 1.0 1.1 9.5 230 1441 25 6.45 1.2 1.2 11.5 340 2291 35 7.65 1.2 1.2 12.5 440 3081 70 10.85 1.4 1.3 16.5 820 620Range and dimensionsOrdering informationNumber of cores Cross section core,mm²Max. conductorresistance at 20°C,Ohm/kmMax. conductorresistance at 90°C,Ohm/kmCurrent rating IEC60092-352 TableB.4, AmpereShort circuit rating 1second, Ampere1 6 3.11 3.97 52 8401 16 1.16 1.48 96 22401 25 0.734 0.936 127 35001 35 0.529 0.675 157 49001 70 0.27 0.344 242 9800Electrical valuesAmbientTemp °C35 40 45 50 55 60 65 70 75 80Ratingfactor1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47Minimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature8 x DOD < 25 mm - 4 x D, OD > 25mm - 6 x D50 N /mm² -20°CInstallation recommendationsAmbient temperature correction factors3www.drakaMOG.comInformation subject to change without notice
  5. 5. Marine, Oil & GasRU 0.6/1KV Unarmoured power cableFlame retardant halogen-free power cable.Enhanced oil-resistance.RU 0.6/1kVOperating temperature : 90°COperating Voltage : 0.6/1kVUnarmoured cable for fixed installation where cableprotection is not required. Power, control and lightingin safe areas.Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS6883 - DesignBS6360 class 2 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 - Flame RetardantIEC60332-3-22 - Flame retardantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low SmokeCodeLetterConductor Tinned stranded circular copper, BS6360, class 2Insulation R EP-rubber, GP4 to BS7655:section 1.2Inner sheath No inner sheath, additional tapes may be appliedArmour/screen No armourOuter sheath UFlame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF)SW4 to BS7655 section 2.6. (Mud resistant version available on request)Marking text"metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number ofcores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cableactually supplied)Outer sheathcolourBlackCore identificationAll cores are offwhite with black numbers No 1,2,3…….4Constructionwww.drakaMOG.comInformation subject to change without notice
  6. 6. Marine, Oil & GasRange and dimensionsOrdering informationElectrical valuesMinimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature8 x DOD < 25 mm - 4 x D, OD > 25mm - 6 x D50 N /mm² -20°CInstallation recommendationsAmbientTemp °C35 40 45 50 55 60 65 70 75 80Ratingfactor1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47Ambient temperature correction factors5RU 0.6/1KV Unarmoured power cableNumber ofcoresCross sectioncore, mm²ConductorDiameter, mmInsulationThickness, mmThickness OuterSheath, mmApprox OverallDiameter, mmWeight ofCable Approx.(Kg/Km)Copper contentApprox.(Kg/Km)2 1.5 1.6 0.8 1.1 8.5 120 282 2.5 2.0 0.8 1.1 9.5 150 463 1.5 1.6 0.8 1.1 9 140 423 2.5 2.0 0.8 1.1 10 180 693 4 2.55 1.0 1.2 12 275 1103 6 3.15 1.0 1.2 13.5 360 1644 1.5 1.6 0.8 1.1 10 165 564 2.5 2.0 0.8 1.1 11 220 923 10 4.05 1.0 1.3 15.5 530 2713 16 5.15 1.0 1.4 18 770 434Part number Description Sheath Colour Design standard840300 RU 0.6/1kV 2X 1.5mm² BLACK BS 6883:1999840301 RU 0.6/1kV 2X 2.5mm² BLACK BS 6883:1999840302 RU 0.6/1kV 3X 1.5mm² BLACK BS 6883:1999840303 RU 0.6/1kV 3X 2.5mm² BLACK BS 6883:1999840304 RU 0.6/1kV 3X 4mm² BLACK BS 6883:1999840305 RU 0.6/1kV 3X 6mm² BLACK BS 6883:1999840306 RU 0.6/1kV 4X 1.5mm² BLACK BS 6883:1999840307 RU 0.6/1kV 4X 2.5mm² BLACK BS 6883:1999840312 RU 0.6/1kV 3X 10mm² BLACK BS 6883:1999840313 RU 0.6/1kV 3X 16mm² BLACK BS 6883:1999Number ofcoresCross sectioncore, mm²Max. conductorresistance at20°C, Ohm/kmMax. conductorresistance at90°C, Ohm/kmReactance at50Hz, Ohm/kmReactance at60Hz, Ohm/kmCurrent ratingIEC 60092-352Table B.4,AmpereShort circuitrating 1second,Ampere2 1.5 12.2 15.6 0.103 0.123 20 2102 2.5 7.56 9.64 0.096 0.115 26 3503 1.5 12.2 15.6 0.103 0.123 16 2103 2.5 7.56 9.64 0.096 0.115 21 3503 4 4.7 5.90 0.096 0.115 28 5603 6 3.11 3.97 0.090 0.108 36 8404 1.5 12.2 15.6 0.103 0.123 16 2104 2.5 7.56 9.64 0.096 0.115 21 3503 10 1.84 2.35 0.084 0.101 50 14003 16 1.16 1.48 0.080 0.096 67 2240www.drakaMOG.comInformation subject to change without notice
  7. 7. Marine, Oil & GasRFCU 0.6/1KV Power, Control or Lighting cableFlame retardant halogen-free power cable.Enhanced oil-resistance.RFCU 0.6/1kVOperating temperature : 90°COperating Voltage : 0,6/1kVArmoured cable for fixed installation for power,control or lighting in both EX and safe areas wherecable protection is required. General purpose use.Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS6883 / UKOOA - DesignBS6360 class 2 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 - Flame RetardantIEC60332-3-22 - Flame retardantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low Smoke6CodeLetterConductor Tinned stranded circular copper, BS 6360, class 2Insulation R EP-rubber, GP4 to BS 7655: section 1.2Lay up / Shielding Cores laid up in concentric layersInner covering F Flame retardant and halogen-free thermoset compoundTape over innercoveringPET tape + rubberized Polyamide tapeArmour/screen C Galvanized steel wire braidTape over armour/screenPET tape + rubberised Polyamide tapeOuter sheathU Flame retardant, halogen-free, enhanced oil-resisting thermoset compound(LSF), SW4 to BS 7655 section 2.6Marking text"metre mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "numberof cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differon cable actually supplied)Outer sheath colour BlackConstructionCore identificationAll cores are offwhite with black numbers No 1,2,3…….www.drakaMOG.comInformation subject to change without notice
  8. 8. RFCU 0.6/1KV Power, Control or Lighting cableMarine, Oil & GasRange and dimensions7Number ofcoresCrosssectioncore, mm²ConductorDiameter,mmInsulationThickness,mmThicknessInnerSheath,mmApproxDiameterinnerSheath,mmDiameterBraid Wire,mmThicknessOuterSheath,mmApproxOverallDiameter,mmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)2 1.5 1.6 0.8 1.1 8.5 0.3 1.2 12.5 280 282 2.5 2.0 0.8 1.1 9.5 0.3 1.2 13.5 320 462 4 2.55 1.0 1.2 11.5 0.3 1.3 15.5 440 743 1.5 1.6 0.8 1.1 9 0.3 1.2 13 310 423 2.5 2.0 0.8 1.1 10 0.3 1.3 14 360 693 4 2.55 1.0 1.2 12.5 0.3 1.3 16.5 490 1103 6 3.15 1.0 1.2 13.5 0.3 1.4 18 610 1643 16 5.15 1.0 1.4 18.5 0.3 1.6 23 1120 4343 35 7.65 1.2 1.7 25.5 0.45 1.9 31 2150 9273 70 10.85 1.4 2 34 0.45 2.2 40 3770 18634 1.5 1.6 0.8 1.1 10 0.3 1.3 14 350 564 4 2.55 1.0 1.2 13.5 0.3 1.4 18 590 1474 6 3.15 1.0 1.3 15 0.3 1.5 19.5 740 2184 16 5.15 1.0 1.5 20.5 0.3 1.7 25.5 1390 5784 25 6.45 1.2 1.7 25 0.45 1.9 31 2130 9174 35 7.65 1.2 1.8 28 0.45 2 34 2620 12367 2.5 2.0 0.8 1.2 13.5 0.3 1.4 18.5 590 16112 2.5 2.0 0.8 1.4 18 0.3 1.6 22.5 900 27519 2.5 2.0 0.8 1.5 21 0.3 1.7 27 1240 4354 70 10.85 1.4 2.1 38 0.45 2.4 44 4670 24843 10 4.05 1.0 1.3 16 0.3 1.5 20.5 830 2713 25 6.45 1.2 1.6 22.5 0.3 1.8 28 1640 6884 10 4.05 1.0 1.4 17.5 0.3 1.6 22.5 1000 36119 1.5 1.6 0.8 1.4 19 0.3 1.6 24 960 2644 50 9.0 1.4 1.9 33 0.45 2.2 39.5 3480 17164 95 12.60 1.6 2.3 43.5 0.45 2.6 50.5 6080 33512 6 3.15 1.0 1.2 13 0.3 1.4 17 540 1094 6 3.15 1.0 1.3 15 0.3 1.5 19.5 740 21837 2.5 2.0 0.8 1.8 29 0.45 2 35 2270 8472 16 5.15 1.0 1.4 17.5 0.3 1.5 22 940 28927 2.5 2.0 0.8 1.7 25.5 0.45 1.9 31.5 1820 6187 1.5 1.6 0.8 1.2 12 0.3 1.3 17 470 9812 1.5 1.6 0.8 1.3 16 0.3 1.5 20.5 710 1672 35 7.65 1.2 1.6 23.5 0.3 1.8 28.5 1650 6183 50 9.0 1.4 1.8 29.5 0.45 2 35 2830 12874 2.5 2.0 0.8 1.1 11 0.3 1.3 15 420 923 95 12.60 1.6 2.2 39 0.45 2.4 45 4860 25135 1.5 1.6 0.8 1.1 11 0.3 1.3 15 440 83www.drakaMOG.comInformation subject to change without notice
  9. 9. RFCU 0.6/1KV Power, Control or Lighting cableMarine, Oil & Gas8Ordering informationPart number Description Sheath Colour Design standard UKOOA Code840049 RFCU 0.6/1kV 2X 1.5mm² BLACK BS 6883 : 1999 WB202840050 RFCU 0.6/1kV 2X 2.5mm² BLACK BS 6883 : 1999 WB203840051 RFCU 0.6/1kV 2X 4mm² BLACK BS 6883 : 1999 WB204840052 RFCU 0.6/1kV 3X 1.5mm² BLACK BS 6883 : 1999 WB302840053 RFCU 0.6/1kV 3X 2.5mm² BLACK BS 6883 : 1999 WB303840054 RFCU 0.6/1kV 3X 4mm² BLACK BS 6883 : 1999 WB304840055 RFCU 0.6/1kV 3X 6mm² BLACK BS 6883 : 1999 WB306840056 RFCU 0.6/1kV 3X 16mm² BLACK BS 6883 : 1999 WB316840057 RFCU 0.6/1kV 3X 35mm² BLACK BS 6883 : 1999 WB335840058 RFCU 0.6/1kV 3X 70mm² BLACK BS 6883 : 1999 WB370840059 RFCU 0.6/1kV 4X 1.5mm² BLACK BS 6883 : 1999 WB402840061 RFCU 0.6/1kV 4X 4mm² BLACK BS 6883 : 1999 WB404840062 RFCU 0.6/1kV 4X 6mm² BLACK BS 6883 : 1999 WB406840063 RFCU 0.6/1kV 4X 16mm² BLACK BS 6883 : 1999 WB416840064 RFCU 0.6/1kV 4X 25mm² BLACK BS 6883 : 1999 WB425840065 RFCU 0.6/1kV 4X 35mm² BLACK BS 6883 : 1999 WB435840068 RFCU 0.6/1kV 7X 2.5mm² BLACK BS 6883 : 1999 WB703840070 RFCU 0.6/1kV 12X 2.5mm² BLACK BS 6883 : 1999 WBA03840071 RFCU 0.6/1kV 19X 2.5mm² BLACK BS 6883 : 1999 WBB03840088 RFCU 0.6/1kV 4X 70mm² BLACK BS 6883 : 1999 WB470840154 RFCU 0.6/1kV 3X 10mm² BLACK BS 6883 : 1999 WB310840158 RFCU 0.6/1kV 3X 25mm² BLACK BS 6883 : 1999 WB325840159 RFCU 0.6/1kV 4X 10mm² BLACK BS 6883 : 1999 WB410840160 RFCU 0.6/1kV 19X 1.5mm² BLACK BS 6883 : 1999 WBB02840166 RFCU 0.6/1kV 4X 50mm² BLACK BS 6883 : 1999 WB450840242 RFCU 0.6/1kV 4X 95mm² BLACK BS 6883 : 1999 WB495840245 RFCU 0.6/1kV 2X 6mm² BLACK BS 6883 : 1999 WB206840246 RFCU 0.6/1kV 4X 6mm² BLACK BS 6883 : 1999 WB406840256 RFCU 0.6/1kV 37X 2.5mm² BLACK BS 6883 : 1991 WBD03840258 RFCU 0.6/1kV 2X 16mm² BLACK BS 6883 : 1999 WB216840262 RFCU 0.6/1kV 27X 2.5mm² BLACK BS 6883 : 1991 WBC03840263 RFCU 0.6/1kV 7X 1.5mm² BLACK BS 6883 : 1999 WB702840264 RFCU 0.6/1kV 12X 1.5mm² BLACK BS 6883 : 1999 WBA02840269 RFCU 0.6/1kV 2X 35mm² BLACK BS 6883 : 1999 WB235840283 RFCU 0.6/1kV 3X 50mm² BLACK BS 6883 : 1999 WB350840284 RFCU 0.6/1kV 4X 2.5mm² BLACK BS 6883 : 1999 WB403840311 RFCU 0.6/1kV 3X 95mm² BLACK BS 6883 : 1999 WB395840338 RFCU 0.6/1kV 5X 1.5mm² BLACK BS 6883 : 1999 -www.drakaMOG.comInformation subject to change without notice
  10. 10. RFCU 0.6/1KV Power, Control or Lighting cableMarine, Oil & Gas9www.drakaMOG.comInformation subject to change without noticeElectrical valuesNumber ofcoresCross sectioncore, mm²Max. conductorresistance at20°C, Ohm/kmMax. conductorresistance at90°C, Ohm/kmReactance at50Hz, Ohm/kmReactance at60Hz, Ohm/kmCurrent ratingIEC 60092-352Table B.4,AmpereShort circuitrating 1second,Ampere2 1.5 12.2 15.6 0.103 0.123 20 2102 2.5 7.56 9.64 0.096 0.115 26 3502 4 4.7 5.99 0.096 0.115 34 5603 1.5 12.2 15.6 0.103 0.123 16 2103 2.5 7.56 9.64 0.096 0.115 21 3503 4 4.7 5.99 0.096 0.115 28 5603 6 3.11 3.97 0.090 0.108 36 8403 16 1.16 1.48 0.080 0.096 67 22403 35 0.529 0.675 0.076 0.092 110 49003 70 0.27 0.344 0.074 0.088 169 98004 1.5 12.2 15.6 0.103 0.123 16 2104 4 4.7 5.99 0.096 0.115 28 5604 6 3.11 3.97 0.090 0.108 36 8404 16 1.16 1.48 0.080 0.096 67 22404 25 0.734 0.936 0.079 0.095 89 35004 35 0.529 0.675 0.076 0.092 110 49007 2.5 7.56 9.64 0.096 0.115 15.5 35012 2.5 7.56 9.64 0.096 0.115 13 35019 2.5 7.56 9.64 0.096 0.115 11 3504 70 0.27 0.344 0.074 0.088 169 98003 10 1.84 2.35 0.084 0.101 50 14003 25 0.734 0.936 0.079 0.095 89 35004 10 1.84 2.35 0.084 0.101 50 140019 1.5 12.2 15.6 0.103 0.123 8.5 2104 50 0.391 0.499 0.076 0.092 137 70004 95 0.195 0.249 0.073 0.088 205 133002 6 3.11 3.97 0.090 0.108 44 8404 6 3.11 3.97 0.090 0.108 36 84037 2.5 7.56 9.64 0.096 0.115 9 3502 16 1.16 1.48 0.080 0.096 80 224027 2.5 7.56 9.64 0.096 0.115 10 3507 1.5 12.2 15.6 0.103 0.123 12 21012 1.5 12.2 15.6 0.103 0.123 10 2102 35 0.529 0.675 0.076 0.092 133 49003 50 0.391 0.499 0.076 0.092 137 70004 2.5 7.56 9.64 0.096 0.115 21 3503 95 0.195 0.249 0.073 0.088 205 133005 1.5 12.2 15.6 0.103 0.123 13.5 210Minimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature8 x DOD < 25 mm - 4 x D, OD > 25mm - 6 x D50 N /mm² -20°CInstallation recommendationsAmbientTemp °C35 40 45 50 55 60 65 70 75 80Ratingfactor1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47Ambient temperature correction factors
  11. 11. Marine, Oil & GasRFCU(C) 250V, Collective screened instrumentationFlame retardant halogen-free instrumentationcable. Enhanced oil-resistance.RFCU(C) 250VOperating temperature : 90°COperating Voltage : 250VFixed installation for instrumentation, communication,control and alarm systems in both EX– and safe areas.Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS6883 / UKOOA - DesignBS6360 class 2 or 5 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 - Flame RetardantIEC60332-3-22 - Flame retardantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low Smoke10CodeLetterConductorTinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)Insulation R EP-rubber, GP4 to BS 7655: section 1.2Pair/Triple/QuadtwistingColour coded cores twisted together to form a pair, triple or quad, wrappedwith polyester tape. Pairs, triples or quads are laid up, collectively screenedwith aluminium backed polyester tape with tinned copper drain wire. Pairs,triples, or quads are identified by numbers printed directly on the insulatedconductors.Inner covering F Flame retardant and halogen-free thermoset compoundTape over innercoveringPET tape + rubberized Polyamide tapeArmour/screen C Galvanized steel wire braidTape over armour/screenPET tape + rubberised Polyamide tapeOuter sheathU Flame retardant, halogen-free, enhanced oil-resisting thermoset compound(LSF), SW4 to BS 7655 section 2.6Marking text"metre mark" "year" "DRAKA" "RFCU(C)" "UKOOA code" "150/250V""number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)Outer sheath colour Grey or BlueConstructionCore identificationPair - Black—White, numbered 1-1, 2-2, 3-3 ……Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 ……Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 …..Each core is identified by contrasting numerals & words repeatedalong the whole length of the cable.www.drakaMOG.comInformation subject to change without notice
  12. 12. Marine, Oil & Gas11www.drakaMOG.comInformation subject to change without noticeRFCU(C) 250V, Collective screened instrumentationRange and dimensionsNumberofelementsNo ofcores inelementCrosssectioncore, mm²ConductorDiameter,mmInsulationThicknessmmThicknessInnerSheath,mmDiameterInnerSheath,mmDiameterBraidWire, mmThicknessOuterSheath,mmApproxOverallDiameter ,mmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 420 457 2 0.75 1.15 0.8 1.4 16.5 0.3 1.5 21 660 9712 2 0.75 1.15 0.8 1.6 21.5 0.3 1.7 26 1000 16427 2 0.75 1.15 0.8 1.9 29 0.45 2.2 35.5 1980 3593 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 420 457 2 0.75 1.15 0.8 1.4 16.5 0.3 1.5 21 660 9712 2 0.75 1.15 0.8 1.6 21.5 0.3 1.7 26 1000 16419 2 0.75 1.15 0.8 1.7 24.5 0.45 1.9 30 1460 25727 2 0.75 1.15 0.8 1.9 29 0.45 2.2 35.5 1980 3592 2 1 1.3 0.8 1.2 12 0.3 1.4 16.5 400 4120 2 0.75 1.15 0.8 1.8 25.5 0.45 2 31.5 1570 27120 2 0.75 1.15 0.8 1.8 25.5 0.45 2 31.5 1570 2717 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 850 18312 2 1.5 1.6 0.8 1.7 24.5 0.45 1.9 30 1470 30920 2 1.5 1.6 0.8 1.9 29 0.45 2.2 35.5 2130 51127 2 1.5 1.6 0.8 2.1 33.5 0.45 2.4 40 2650 6877 3 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 820 14412 3 0.75 1.15 0.8 1.7 24 0.3 1.9 29 1290 2443 3 0.75 1.15 0.8 1.3 13.5 0.3 1.4 18 510 653 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 823 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 823 2 1 1.3 0.8 1.2 12.5 0.3 1.4 17 460 583 3 0.75 1.15 0.8 1.3 13.5 0.3 1.4 18 510 6512 3 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1840 4613 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 825 2 1.5 1.6 0.8 1.4 17 0.3 1.6 21.5 730 1322 2 0.75 1.15 0.8 1.2 11.5 0.3 1.3 15.5 370 312 2 1.5 1.6 0.8 1.2 13 0.3 1.4 17 450 575 2 0.75 1.15 0.8 1.3 15 0.3 1.5 19.5 570 71
  13. 13. RFCU(C) 250V, Collective screened instrumentationMarine, Oil & Gas12www.drakaMOG.comInformation subject to change without noticeElectrical valuesTypeCapacitance,approx. (nF/km)Inductance,approx, (mH/km)Resistance at20°C, max.(Ohm/km)L/R ratio,(microH/Ohm)Insulationresistance(MinimumMohm x km)Unshielded pair 0,75 mm² 80 0,75 26,7 14 940Unshielded triple 0,75 mm² 80 0,75 26,7 14 940Unshielded pair 1,0 mm² 85 0,73 20,0 18 840Unshielded triple 1,0 mm² 85 0,73 20,0 18 840Unshielded pair 1,5 mm² 90 0,68 13,7 24,8 730Unshielded triple 1,5 mm² 90 0,68 13,7 24,8 730Unshielded pair 2,5 mm² 90 0,70 7,56 46,3 620Unshielded triple 2,5 mm² 90 0,70 7,56 46,3 620Ordering informationPart number Description Sheath Colour Design standard UKOOA Code840003 RFCU(C) 250V 3PAIR 0.75mm² GREY BS 6883 : 1999 KJH00840004 RFCU(C) 250V 7PAIR 0.75mm² GREY BS 6883 : 1999 KJJ00840005 RFCU(C) 250V 12PAIR 0.75mm² GREY BS 6883 : 1999 KJK00840007 RFCU(C) 250V 27PAIR 0.75mm² GREY BS 6883 : 1999 KJM00840023 RFCU(C) 250V 3PAIR 0.75mm² BLUE BS 6883 : 1999 KGH00840024 RFCU(C) 250V 7PAIR 0.75mm² BLUE BS 6883 : 1999 KGJ00840025 RFCU(C) 250V 12PAIR 0.75mm² BLUE BS 6883 : 1999 KGK00840026 RFCU(C) 250V 19PAIR 0.75mm² BLUE BS 6883 : 1991 -840027 RFCU(C) 250V 27PAIR 0.75mm² BLUE BS 6883 : 1999 KGM00840117 RFCU(C) 250V 2PAIR 1mm² GREY BS 6883 : 1991 -840128 RFCU(C) 250V 20PAIR 0.75mm² GREY BS 6883 : 1999 KJL00840156 RFCU(C) 250V 20PAIR 0.75mm² BLUE BS 6883 : 1999 KGL00840176 RFCU(C) 250V 7PAIR 1.5mm² GREY BS 6883 : 1991 KJJ02840177 RFCU(C) 250V 12PAIR 1.5mm² GREY BS 6883 : 1991 KJK02840178 RFCU(C) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 KJL02840179 RFCU(C) 250V 27PAIR 1.5mm² GREY BS 6883 : 1991 KJM02840222 RFCU(C) 250V 7TRIP 0.75mm² BLUE BS 6883 : 1999 KGT00840223 RFCU(C) 250V 12TRIP 0.75mm² BLUE BS 6883 : 1999 KGU00840231 RFCU(C) 250V 3TRIP 0.75mm² GREY BS 6883 : 1999 KJS00840236 RFCU(C) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 KGH02840237 RFCU(C) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 KJH02840241 RFCU(C) 250V 3PAIR 1mm² GREY BS 6883 : 1999 KJH01840274 RFCU(C) 250V 3TRIP 0.75mm² GREY BS 6883 : 1999 KJS00840277 RFCU(C) 250V 12TRIP 1.5mm² BLUE BS 6883 : 1991 KGU02840294 RFCU(C) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 KJH02840295 RFCU(C) 250V 5PAIR 1.5mm² GREY BS 6883 : 1991 -840332 RFCU(C) 250V 2PAIR 0.75mm² GREY BS 6883 : 1991 -840333 RFCU(C) 250V 2PAIR 1.5mm² GREY BS 6883 : 1991 -840334 RFCU(C) 250V 5PAIR 0.75mm² GREY BS 6883 : 1991 -
  14. 14. 13www.drakaMOG.comInformation subject to change without noticeInstallation recommendationsMinimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature10 x D 8 x D 50 N /mm² -20°CMarine, Oil & GasRFCU(C) 250V, Collective screened instrumentation
  15. 15. Marine, Oil & GasRFCU(I) 250V, Individual screened instrumentationFlame retardant halogen-free instrumentationcable. Enhanced oil-resistance.RFCU(I) 250VOperating temperature : 90°COperating Voltage : 250VFixed installation for instrumentation, communication,control and alarm systems in both EX– and safe areas.Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS6883 / UKOOA - DesignBS6360 class 2 or 5 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 - Flame RetardantIEC60332-3-22 - Flame retardantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low Smoke14CodeLetterConductorTinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)Insulation R EP-rubber, GP4 to BS 7655: section 1.2Pair/Triple/Quadtwisting / lay upColour coded cores twisted together to form a pair, triple or quad, which isindividually screened with aluminium backed polyester tape with a tinnedcopper drain wire. Each pair, triple or quad is wrapped with polyester tape toprevent electrical contact with adjacent pairs, triples or quads.Individually shielded pairs, triples or quads are laid up in concentric layers andwrapped with a PETP tape.Pairs, triples, or quads are identified by numbers printed directly on theinsulated conductors.Inner covering F Flame retardant and halogen-free thermoset compoundTape over innercoveringPET tape + rubberized Polyamide tapeArmour/screen C Galvanized steel wire braidTape over armour/screenPET tape + rubberised Polyamide tapeOuter sheathU Flame retardant, halogen-free, enhanced oil-resisting thermoset compound(LSF), SW4 to BS 7655 section 2.6Marking text"metre mark" "year" "DRAKA" "RFCU(I)" "UKOOA code" "150/250V""number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied)Outer sheath colour Grey or BlueConstructionCore identificationPair - Black—White, numbered 1-1, 2-2, 3-3 ……Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 ……Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 …..Each core is identified by contrasting numerals & words repeatedalong the whole length of the cable.www.drakaMOG.comInformation subject to change without notice
  16. 16. Marine, Oil & Gas15www.drakaMOG.comInformation subject to change without noticeRFCU(I) 250V, Individual screened instrumentationRange and dimensionsNumberofelementsNo ofcores inelementCrosssectioncore, mm²ConductorDiameter,mmInsulationThicknessmmThicknessInnerSheath,mmApproxDiameterInnerSheath,mmDiameterBraidWire, mmThicknessOuterSheath,mmApproxOverallDiametermmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)1 2 0.75 1.15 0.8 1 7.5 0.3 1.2 11.5 230 181 4 0.75 1.15 0.8 1.2 9 0.3 1.3 13.5 310 311 2 0.75 1.15 0.8 1 7.5 0.3 1.2 11.5 230 181 4 0.75 1.15 0.8 1.2 9 0.3 1.3 13.5 310 311 2 1 1.3 0.8 1 8 0.3 1.2 12 240 241 2 1 1.3 0.8 1 8 0.3 1.2 12 240 241 4 1 1.3 0.8 1.2 9.5 0.3 1.4 14 340 413 2 1 1.3 0.8 1.3 13 0.3 1.4 17 490 711 3 1 1.3 0.8 1.1 8.5 0.3 1.2 12.5 285 327 3 0.75 1.15 0.8 1.5 18.5 0.3 1.7 23.5 900 17012 3 0.75 1.15 0.8 1.7 25 0.45 2 31 1530 2937 2 0.75 1.15 0.8 1.4 16.5 0.3 1.6 21 720 1247 2 0.75 1.15 0.8 1.4 16.5 0.3 1.6 21 720 12412 2 0.75 1.15 0.8 1.6 22 0.3 1.8 27 1110 21212 2 0.75 1.15 0.8 1.6 22 0.3 1.8 27 1110 2123 3 0.75 1.15 0.8 1.3 14 0.3 1.5 18.5 530 733 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 430 533 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 430 5320 2 1.5 1.6 0.8 2 31.5 0.45 2.3 38 2430 63519 2 0.75 1.15 0.8 1.8 26 0.45 2 32 1660 33612 3 0.75 1.15 0.8 1.7 25 0.45 2 31 1530 2937 3 0.75 1.15 0.8 1.5 18.5 0.3 1.7 23.5 900 1703 2 1.5 1.6 0.8 1.3 14 0.3 1.5 18.5 560 953 3 0.75 1.15 0.8 1.3 14 0.3 1.5 18.5 530 733 2 1.5 1.6 0.8 1.3 14 0.3 1.5 18.5 560 951 2 1.5 1.6 0.8 1.1 8.5 0.3 1.2 12.5 290 321 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 320 451 3 0.75 1.15 0.8 1 8 0.3 1.2 12 245 251 4 1 1.3 0.8 1.2 9.5 0.3 1.4 14 340 411 4 1.5 1.6 0.8 1.2 10 0.3 1.4 14.5 370 571 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 320 45
  17. 17. Marine, Oil & Gas16www.drakaMOG.comInformation subject to change without noticeRFCU(I) 250V, Individual screened instrumentationElectrical valuesTypeCapacitance,approx. (nF/km)Inductance,approx (mH/km)Resistance at 20°C,max. (Ohm/km)L/R ratio, (microH/Ohm)Insulationresistance(Minimum MOhmxkm)Shielded pair 0,75 mm² 90 0,75 26,7 14 940Shielded triple 0,75 mm² 90 0,75 26,7 14 940Shielded quad 0,75 mm² 60 0,91 26,7 14 940Shielded pair 1 mm² 100 0,73 20,0 18 840Shielded triple 1 mm² 100 0,73 20,0 18 840Shielded quad 1 mm² 70 0,95 20,0 18 840Shielded pair 1,5 mm² 110 0,68 13,7 24,8 730Shielded triple 1,5 mm² 110 0,68 13,7 24,8 730Shielded quad 1,5 mm² 80 0,99 13,7 24,8 730Shielded pair 2,5 mm² 120 0,70 7,56 46,3 620Part number Description Sheath Colour Design standard UKOOA Code840001 RFCU(I) 250V 1PAIR 0.75mm² GREY BS 6883 : 1999 KKF00840002 RFCU(I) 250V 1QUAD 0.75mm² GREY BS 6883 : 1999 KKX00840021 RFCU(I) 250V 1PAIR 0.75mm² BLUE BS 6883 : 1999 KHF00840022 RFCU(I) 250V 1QUAD 0.75mm² BLUE BS 6883 : 1999 KHX00840094 RFCU(I) 250V 1PAIR 1mm² GREY BS 6883 : 1999 KKF01840095 RFCU(I) 250V 1PAIR 1mm² BLUE BS 6883 : 1999 KHF01840096 RFCU(I) 250V 1QUAD 1mm² BLUE BS 6883 : 1999 KHX01840100 RFCU(I) 250V 3PAIR 1mm² BLUE BS 6883 : 1999 KHH01840121 RFCU(I) 250V 1TRIP 1mm² GREY BS 6883 : 1999 KKR01840211 RFCU(I) 250V 7TRIP 0.75mm² BLUE BS 6883 : 1999 KHT00840212 RFCU(I) 250V 12TRIP 0.75mm² BLUE BS 6883 : 1999 KHU00840214 RFCU(I) 250V 7PAIR 0.75mm² GREY BS 6883 : 1999 KKJ00840215 RFCU(I) 250V 7PAIR 0.75mm² BLUE BS 6883 : 1999 KHJ00840216 RFCU(I) 250V 12PAIR 0.75mm² GREY BS 6883 : 1999 KKK00840221 RFCU(I) 250V 12PAIR 0.75mm² BLUE BS 6883 : 1999 KHK00840224 RFCU(I) 250V 3TRIP 0.75mm² BLUE BS 6883 : 1999 KHS00840226 RFCU(I) 250V 3PAIR 0.75mm² GREY BS 6883 : 1999 KKH00840227 RFCU(I) 250V 3PAIR 0.75mm² BLUE BS 6883 : 1999 KHH00840235 RFCU(I) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 KKL02840238 RFCU(I) 250V 19PAIR 0.75mm² BLUE BS 6883 : 1991 -840239 RFCU(I) 250V 12TRIP 0.75mm² GREY BS 6883 : 1999 KKU00840272 RFCU(I) 250V 7TRIP 0.75mm² GREY BS 6883 : 1999 KKT00840275 RFCU(I) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 KKH02840276 RFCU(I) 250V 3TRIP 0.75mm² GREY BS 6883 : 1999 KKS00840278 RFCU(I) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 KHH02840293 RFCU(I) 250V 1PAIR 1.5mm² GREY BS 6883 : 1991 KKF02840296 RFCU(I) 250V 1TRIP 1.5mm² GREY BS 6883 : 1991 KKR02840335 RFCU(I) 250V 1TRIP 0.75mm² GREY BS 6883 : 1999 KKR00840336 RFCU(I) 250V 1QUAD 1mm² GREY BS 6883 : 1999 KKX01840337 RFCU(I) 250V 1QUAD 1.5mm² GREY BS 6883 : 1991 KKX02840339 RFCU(I) 250V 1TRIP 1.5mm² BLUE BS 6883 : 1991 KHR02Ordering information
  18. 18. Marine, Oil & Gas17www.drakaMOG.comInformation subject to change without noticeRFCU(I) 250V, Individual screened instrumentationMinimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature10 x D 8 x D 50 N /mm² -20°CInstallation recommendations
  19. 19. Marine, Oil & GasBFCU 0.6/1KV Fire resistant Power, Control or Lighting cableFire resistant, Flame retardant halogen-freepower cable. Enhanced oil-resistance.BFCU 0.6/1kVOperating temperature : 90°COperating Voltage : 0.6/1kVArmoured cable for fixed installation for power,control or lighting in both EX and safe areas,emergency and critical systems where there is arequirement for fire resistant cables.Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS7917/BS6883/UKOOA - DesignBS6360 class 2 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 &3-22 - Flame RetardantIEC60331-21 - Fire ResistantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low Smoke18CodeLetterConductor Tinned stranded circular copper, BS 6360, class 2Insulation B Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2Lay up / Shielding Cores laid up in concentric layersInner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compoundTape over innercoveringPET tape + rubberized Polyamide tapeArmour/screen C Galvanized steel wire braidTape over armour/screenPET tape + rubberised Polyamide tapeOuter sheathU Flame retardant, halogen-free, enhanced oil-resisting thermoset compound(LSF), SW4 to BS 7655 section 2.6Marking text"metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "numberof cores" "conductor size" "BS7917" "IEC60331-21” “IEC60332-3-22" (markingmay differ on cable actually supplied)Outer sheath colour BlackConstructionCore identificationAll cores are offwhite with black numbers No 1,2,3…….www.drakaMOG.comInformation subject to change without notice
  20. 20. Marine, Oil & Gas19www.drakaMOG.comInformation subject to change without noticeBFCU 0.6/1KV Fire resistant Power, Control or Lighting cableNumber ofcoresCrosssectioncore, mm²ConductorDiameter,mmInsulationThickness,mmThicknessInnerSheath,mmApproxDiameterInnerSheath,mmDiameterBraid Wire,mmThicknessOuterSheath,mmApproxOverallDiameter,mmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)2 2.5 2.0 0.8 1.1 10 0.3 1.2 14 350 463 1.5 1.6 0.8 1.1 10 0.3 1.2 14 340 423 2.5 2.0 0.8 1.1 10.5 0.3 1.3 15 410 694 1.5 1.6 0.8 1.1 11 0.3 1.3 15 400 564 2.5 2.0 0.8 1.1 11.5 0.3 1.3 16 450 927 2.5 2.0 0.8 1.2 14 0.3 1.4 18.5 620 16112 2.5 2.0 0.8 1.4 19 0.3 1.6 24 960 27527 2.5 2.0 0.8 1.7 27.5 0.45 1.9 33.5 1900 61819 2.5 2.0 0.8 1.5 22.5 0.3 1.7 27.5 1360 4354 70 10.85 1.4 2.1 38 0.45 2.4 45 4650 24843 4 2.55 1.0 1.2 13 0.3 1.3 17 540 1102 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 295 2812 1.5 1.6 0.8 1.3 17.5 0.3 1.5 22 770 1673 6 3.15 1.0 1.2 14.5 0.3 1.4 18.5 650 1642 4 2.55 1.0 1.2 12.5 0.3 1.3 16.5 470 743 10 4.05 1.0 1.3 16.5 0.3 1.5 21 840 2712 10 4.05 1.0 1.3 15.5 0.3 1.4 20 710 1813 25 6.45 1.2 1.6 23.5 0.3 1.8 28.5 1710 6882 6 3.15 1.0 1.2 13.5 0.3 1.4 18 570 1092 16 5.15 1.0 1.4 18 0.3 1.5 22.5 780 2894 6 3.15 1.0 1.3 16 0.3 1.5 20.5 790 2184 35 7.65 1.2 1.8 29 0.45 2 35 2700 12362 35 7.65 1.2 1.6 24.5 0.3 1.8 29.5 1740 6183 35 7.65 1.2 1.7 26 0.45 1.9 32 2210 9273 16 5.15 1.0 1.4 19 0.3 1.6 24 1160 4343 50 9.0 1.4 1.8 30.5 0.45 2 36.5 2890 12933 70 10.85 1.4 2 34.5 0.45 2.2 41 3810 18634 4 2.55 1.0 1.2 14.5 0.3 1.4 18.5 630 1473 95 12.60 1.6 2.2 39.5 0.45 2.4 46.5 4950 25137 1.5 1.6 0.8 1.2 13 0.3 1.3 17 520 98Range and dimensions
  21. 21. Marine, Oil & Gas20www.drakaMOG.comInformation subject to change without noticeBFCU 0.6/1KV Fire resistant Power, Control or Lighting cablePart number Description Sheath Colour Design standard UKOOA Code840073 BFCU 0.6/1kV 2X 2.5mm² BLACK BS 7917 : 1999 YD203840074 BFCU 0.6/1kV 3X 1.5mm² BLACK BS 7917 : 1999 YD302840075 BFCU 0.6/1kV 3X 2.5mm² BLACK BS 7917 : 1999 YD303840076 BFCU 0.6/1kV 4X 1.5mm² BLACK BS 7917 : 1999 YD402840077 BFCU 0.6/1kV 4X 2.5mm² BLACK BS 7917 : 1999 YD403840078 BFCU 0.6/1kV 7X 2.5mm² BLACK BS 7917 : 1999 YD703840079 BFCU 0.6/1kV 12X 2.5mm² BLACK BS 7917 : 1999 YDA03840108 BFCU 0.6/1kV 27X 2.5mm² BLACK BS 6883 : 1991 YDC03840136 BFCU 0.6/1kV 19X 2.5mm² BLACK BS 7917 : 1999 YDB03840151 BFCU 0,6/1kV 4X 70 MM2 BLACK BS 7917 : 1999 YD470840153 BFCU 0.6/1kV 3X 4mm² BLACK BS 7917 : 1999 YD304840162 BFCU 0.6/1kV 2X 1.5mm² BLACK BS 7917 : 1999 YD202840165 BFCU 0,6/1kV 12X 1,5mm2 BLACK BS 7917 : 1999 YDA02840167 BFCU 0.6/1kV 3X 6mm² BLACK BS 7917 : 1999 YD306840230 BFCU 0.6/1kV 2X 4mm² BLACK BS 7917 : 1999 YD204840233 BFCU 0.6/1kV 3X 10mm² BLACK BS 7917 : 1999 YD310840243 BFCU 0,6/1kV 2X 10MM2 BLACK BS 7917 : 1999 YD210840248 BFCU 0.6/1kV 3X 25mm² BLACK BS 7917 : 1999 YD325840249 BFCU 0.6/1kV 2X 6mm² BLACK BS 7917 : 1999 YD206840250 BFCU 0,6/1kV 2X 16 MM2 BLACK BS 7917 : 1999 YD216840257 BFCU 0.6/1kV 4X 6mm² BLACK BS 7917 : 1999 YD406Ordering information840259 BFCU 0.6/1kV 4X 35mm² BLACK BS 7917 : 1999 YD435840270 BFCU 0.6/1kV 2X 35mm² BLACK BS 7917 : 1999 YD235840273 BFCU 0.6/1kV 3X 35mm² BLACK BS 7917 : 1999 YD335840297 BFCU 0.6/1kV 3X 16mm² BLACK BS 7917 : 1999 YD316840298 BFCU 0.6/1kV 3X 50mm² BLACK BS 7917 : 1999 YD350840299 BFCU 0.6/1kV 3X 70mm² BLACK BS 7917 : 1999 YD370840308 BFCU 0.6/1kV 4X 4mm² BLACK BS 7917 : 1999 YD404840309 BFCU 0.6/1kV 3X 95mm² BLACK BS 7917 : 1999 YD370840310 BFCU 0.6/1kV 7X 1.5mm² BLACK BS 7917 : 1999 YD702
  22. 22. Marine, Oil & Gas21www.drakaMOG.comInformation subject to change without noticeBFCU 0.6/1KV Fire resistant Power, Control or Lighting cableNumber ofcoresCross sectioncore, mm²Max. conductorresistance at20°C, Ohm/kmMax. conductorresistance at90°C, Ohm/kmReactance at50Hz, Ohm/kmReactance at60Hz, Ohm/kmCurrent ratingIEC 60092-352Table B.4,AmpereShort circuitrating 1second,Ampere2 2.5 7.56 9.64 0.101 0.121 26 3503 1.5 12.2 15.6 0.108 0.130 16 2103 2.5 7.56 9.64 0.101 0.121 21 3504 1.5 12.2 15.6 0.108 0.130 16 2104 2.5 7.56 9.64 0.101 0.121 21 3507 2.5 7.56 9.64 0.101 0.121 15.5 35012 2.5 7.56 9.64 0.101 0.121 13 35027 2.5 7.56 9.64 0.101 0.121 10 35019 2.5 7.56 9.64 0.101 0.121 11 3504 70 0.27 0.344 0.075 0.090 169 98003 4 4.7 5.99 0.100 0.120 28 5602 1.5 12.2 15.6 0.108 0.130 20 21012 1.5 12.2 15.6 0.108 0.130 10 2103 6 3.11 3.97 0.094 0.112 36 8402 4 4.7 5.99 0.100 0.120 34 5603 10 1.84 2.35 0.088 0.105 50 14002 10 1.84 2.35 0.088 0.105 61 14003 25 0.734 0.936 0.081 0.097 89 35002 6 3.11 3.97 0.094 0.112 44 8402 16 1.16 1.48 0.082 0.099 80 22404 6 3.11 3.97 0.094 0.112 36 8404 35 0.529 0.675 0.078 0.094 110 49002 35 0.529 0.675 0.078 0.094 133 49003 35 0.529 0.675 0.078 0.094 110 49003 16 1.16 1.48 0.082 0.099 67 22403 50 0.391 0.499 0.078 0.093 137 70003 70 0.27 0.344 0.075 0.090 169 98004 4 4.7 5.99 0.100 0.120 28 5603 95 0.195 0.249 0.075 0.090 205 133007 1.5 12.2 15.6 0.108 0.130 12 210Electrical valuesMinimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature8 x DOD < 25 mm - 4 x D, OD > 25mm - 6 x D50 N /mm² -20°CInstallation recommendationsAmbientTemp °C35 40 45 50 55 60 65 70 75 80Ratingfactor1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47Ambient temperature correction factors
  23. 23. Marine, Oil & GasBFCU(C) 250V, Fire Resistant, Collective screened instrumentationFire resistant, Flame retardant halogen-freeinstrumentation cable. Enhanced oil-resistance.BFCU(C) 250VOperating temperature : 90°COperating Voltage : 250VFixed installation for instrumentation, communication,control and alarm systems in both EX– and safe areas,emergency and critical systems where there is arequirement for fire resistant cables..Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS7917/BS6883/UKOOA - DesignBS6360 class 2 or 5 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 & 3-22 - Flame RetardantIEC60331-21 - Fire ResistantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low Smoke22CodeLetterConductorTinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)Insulation B Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2Pair/Triple/QuadtwistingColour coded cores twisted together to form a pair, triple or quad, wrappedwith polyester tape. Pairs, triples or quads are laid up, collectively screenedwith aluminium backed polyester tape with tinned copper drain wire. Pairs,triples, or quads are identified by numbers printed directly on the insulatedconductors.Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compoundTape over innercoveringPET tape + rubberized Polyamide tapeArmour/screen C Galvanized steel wire braidTape over armour/screenPET tape + rubberised Polyamide tapeOuter sheathU Flame retardant, halogen-free, enhanced oil-resisting thermoset compound(LSF), SW4 to BS 7655 section 2.6Marking text"metre mark" "year" "DRAKA" "BFCU(C)" "UKOOA code" "150/250V""number of pair, triples or quads" "conductor size" "BS7917" “IEC60331-21”"IEC60332-3-22" (marking may differ on cable actually supplied)Outer sheath colour Grey or BlueConstructionCore identificationPair - Black—White, numbered 1-1, 2-2, 3-3 ……Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 ……Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 …..Each core is identified by contrasting numerals & words repeatedalong the whole length of the cable.www.drakaMOG.comInformation subject to change without notice
  24. 24. Marine, Oil & Gas23www.drakaMOG.comInformation subject to change without noticeBFCU(C) 250V, Fire Resistant, Collective screened instrumentationRange and dimensionsNumberofelementsNo ofcores inelementCrosssectioncore, mm²ConductorDiameter,mmInsulationThicknessmmThicknessInnerSheath,mmApproxDiameterInnerSheath,mmDiameterBraidWire, mmThicknessOuterSheath,mmApproxOverallDiametermmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)3 2 0.75 1.15 0.8 1.2 13 0.3 1.4 17.5 460 457 2 0.75 1.15 0.8 1.4 17.5 0.3 1.5 22 740 9812 2 0.75 1.15 0.8 1.6 22.5 0.3 1.7 27.5 1120 16419 2 0.75 1.15 0.8 1.7 26 0.45 1.9 32 1600 25827 2 0.75 1.15 0.8 1.9 31 0.45 2.2 37.5 2190 3603 2 0.75 1.15 0.8 1.2 13 0.3 1.4 17.5 460 457 2 0.75 1.15 0.8 1.4 17.5 0.3 1.5 22 740 9812 2 0.75 1.15 0.8 1.6 22.5 0.3 1.7 27.5 1120 16419 2 0.75 1.15 0.8 1.7 26 0.45 1.9 32 1600 25827 2 0.75 1.15 0.8 1.9 31 0.45 2.2 37.5 2190 3603 2 1 1.3 0.8 1.2 13.5 0.3 1.4 18 490 582 2 1.5 1.6 0.8 1.2 13.5 0.3 1.4 18 470 5720 2 0.75 1.15 0.8 1.8 27 0.45 2 33 1720 2713 2 1.5 1.6 0.8 1.3 14.5 0.3 1.4 19 570 827 2 1.5 1.6 0.8 1.4 19.5 0.3 1.6 24 920 18312 2 1.5 1.6 0.8 1.7 26 0.45 1.9 31.5 1560 31020 2 0.75 1.15 0.8 1.8 27 0.45 2 33 1720 27120 2 1.5 1.6 0.8 1.9 31 0.45 2.2 37.5 2260 51127 2 1.5 1.6 0.8 2.1 35.5 0.45 2.4 42 2820 6887 3 0.75 1.15 0.8 1.4 19.5 0.3 1.6 24.5 930 14412 3 0.75 1.15 0.8 1.7 26 0.3 1.9 31.5 1450 2453 2 2.5 2 0.8 1.3 16 0.3 1.5 20.5 680 14712 2 2.5 2 0.8 1.8 28.5 0.45 2 34.5 1960 5652 2 0.75 1.15 0.8 1.2 12 0.3 1.3 16.5 390 313 3 0.75 1.15 0.8 1.3 15 0.3 1.4 19 550 657 3 1.5 1.6 0.8 1.5 22 0.3 1.7 27 1180 27112 3 1.5 1.6 0.8 1.8 29.5 0.45 2 35.5 2020 4627 2 1.5 1.6 0.8 1.4 19.5 0.3 1.6 24 920 18320 2 1.5 1.6 0.8 1.9 31 0.45 2.2 37.5 2260 5112 2 1.5 1.6 0.8 1.2 13.5 ± 0.8 0.3 1.4 18 ± 0.8 470 573 2 1.5 1.6 0.8 1.3 14.5 ± 0.8 0.3 1.4 19 ± 0.8 570 825 2 1.5 1.6 0.8 1.4 18 ± 0.8 0.3 1.6 22.5 ± 1 780 1335 2 1.5 1.6 0.8 1.4 18 ± 0.8 0.3 1.6 22.5 ± 1 780 1337 2 1.5 1.6 0.8 1.4 19.5 ± 0.8 0.3 1.6 24 ± 1 920 1832 2 0.75 1.15 0.8 1.2 12 ± 0.8 0.3 1.3 16.5 ± 0.8 390 313 2 1 1.3 0.8 1.2 13.5 ± 0.8 0.3 1.4 18 ± 0.8 490 585 2 0.75 1.15 0.8 1.3 15.5 ± 0.8 0.3 1.5 20 ± 1 620 715 2 0.75 1.15 0.8 1.3 15.5 ± 0.8 0.3 1.5 20 ± 1 620 7112 2 1.5 1.6 0.8 1.7 26 ± 1 0.45 1.9 31.5 ± 1.5 1560 310
  25. 25. Marine, Oil & Gas24www.drakaMOG.comInformation subject to change without noticeBFCU(C) 250V, Fire Resistant, Collective screened instrumentationTypeCapacitance,approx. (nF/km)Inductance,approx, (mH/km)Resistance at 20°C, max. (Ohm/km)L/R ratio,(microH/Ohm)Insulationresistance(Minimum MOhmx km)Unshielded pair 0,75 mm² 80 0,75 26,7 14 940Unshielded triple 0,75 mm² 80 0,75 26,7 14 940Unshielded pair 1,0 mm² 85 0,73 20,0 18 840Unshielded triple 1,0 mm² 85 0,73 20,0 18 840Unshielded pair 1,5 mm² 90 0,68 13,7 24,8 730Unshielded triple 1,5 mm² 90 0,68 13,7 24,8 730Unshielded pair 2,5 mm² 90 0,70 7,56 46,3 620Unshielded triple 2,5 mm² 90 0,70 7,56 46,3 620Electrical valuesPart number Description Sheath Colour Design standard UKOOA Code840011 BFCU(C) 250V 3PAIR 0.75mm² GREY BS 7917 : 1999 GNH00840012 BFCU(C) 250V 7PAIR 0.75mm² GREY BS 7917 : 1999 GNJ00840013 BFCU(C) 250V 12PAIR 0.75mm² GREY BS 7917 : 1999 GNK00840014 BFCU(C) 250V 19PAIR 0.75mm² GREY BS 6883 : 1991 -840015 BFCU(C) 250V 27PAIR 0.75mm² GREY BS 7917 : 1999 GNM00840031 BFCU(C) 250V 3PAIR 0.75mm² BLUE BS 7917 : 1999 GLH00840032 BFCU(C) 250V 7PAIR 0.75mm² BLUE BS 7917 : 1999 GLJ00840033 BFCU(C) 250V 12PAIR 0.75mm² BLUE BS 7917 : 1999 GLK00840034 BFCU(C) 250V 19PAIR 0.75mm² BLUE BS 6883 : 1991 -840035 BFCU(C) 250V 27PAIR 0.75mm² BLUE BS 7917 : 1999 GLM00840090 BFCU(C) 250V 3PAIR 1mm² BLUE BS 7917 : 1999 GLH01840111 BFCU(C) 250V 2PAIR 1.5mm² BLUE BS 6883 : 1991 -840124 BFCU(C) 250V 20PAIR 0.75mm² GREY BS 7917 : 1999 GNL00840132 BFCU(C) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 GNH02840133 BFCU(C) 250V 7PAIR 1.5mm² GREY BS 6883 : 1991 GNJ02840134 BFCU(C) 250V 12PAIR 1.5mm² GREY BS 6883 : 1991 GNK02840144 BFCU(C) 250V 20PAIR 0.75mm² BLUE BS 7917 : 1999 GLL00840171 BFCU(C) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 GNL02840172 BFCU(C) 250V 27PAIR 1.5mm² GREY BS 6883 : 1991 GNM02840173 BFCU(C) 250V 7TRIP 0.75mm² GREY BS 7917 : 1999 GNT00840174 BFCU(C) 250V 12TRIP 0.75mm² GREY BS 7917 : 1999 GNU00Ordering information
  26. 26. Marine, Oil & Gas25www.drakaMOG.comInformation subject to change without noticeBFCU(C) 250V, Fire Resistant, Collective screened instrumentationMinimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature10 x D 8 x D 50 N /mm² -20°CInstallation recommendations840203 BFCU(C) 250V 3PAIR 2.5mm² GREY BS 6883 : 1991 GNH03840205 BFCU(C) 250V 12PAIR 2.5mm² GREY BS 6883 : 1991 GNK03840220 BFCU(C) 250V 2PAIR 0.75mm² GREY BS 6883 : 1991 -840255 BFCU(C) 250V 3TRIP 0.75mm² GREY BS 7917 : 1999 GNS00840260 BFCU(C) 250V 7TRIP 1.5mm² GREY BS 6883 : 1991 GNT02840261 BFCU(C) 250V 12TRIP 1.5mm² GREY BS 6883 : 1991 GNU02840265 BFCU(C) 250V 7PAIR 1.5mm² BLUE BS 6883 : 1991 GLJ02840266 BFCU(C) 250V 20PAIR 1.5mm² BLUE BS 6883 : 1991 GLL02840285 BFCU(C) 250V 2PAIR 1.5mm² GREY BS 6883 : 1991 -840286 BFCU(C) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 GLH02840287 BFCU(C) 250V 5PAIR 1.5mm² GREY BS 6883 : 1991 -840288 BFCU(C) 250V 5PAIR 1.5mm² BLUE BS 6883 : 1991 -840289 BFCU(C) 250V 7PAIR 1.5mm² BLUE BS 6883 : 1991 GLJ02840317 BFCU(C) 250V 2PAIR 0.75mm² BLUE BS 6883 : 1991 -840318 BFCU(C) 250V 3PAIR 1mm² GREY BS 7917 : 1999 GNH01840319 BFCU(C) 250V 5PAIR 0.75mm² GREY BS 6883 : 1991 -840320 BFCU(C) 250V 5PAIR 0.75mm² BLUE BS 6883 : 1991 -840321 BFCU(C) 250V 12PAIR 1.5mm² BLUE BS 6883 : 1991 GLK02Part number Description Sheath Colour Design standard UKOOA Code
  27. 27. Marine, Oil & GasBFCU(I) 250V, Fire Resistant, Individual screened instrumentationFire resistant, Flame retardant halogen-freeinstrumentation cable. Enhanced oil-resistance.BFCU(I) 250VOperating temperature : 90°COperating Voltage : 250VFixed installation for instrumentation, communication,control and alarm systems in both EX– and safe areas,emergency and critical systems where there is arequirement for fire resistant cables..Enhanced MUD resistant version also available for usein areas exposed to mud and drilling / cleaning fluids,meeting the mud resistance requirement in NEK 606.Application Standards appliedBS7917/6883/UKOOA - DesignBS6360 class 2 or 5 - ConductorBS7655 section 1.2 - InsulationBS7655 section 2.6 - SheathIEC 60332-1 & 3-22 - Flame RetardantIEC60331-21 - Fire ResistantIEC60754-1,2 - Halogen FreeIEC 61034-1,2 - Low Smoke26CodeLetterConductorTinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)Insulation B Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2Pair/Triple/Quadtwisting / lay upColour coded cores twisted together to form a pair, triple or quad, which isindividually screened with aluminium backed polyester tape with a tinnedcopper drain wire. Each pair, triple or quad is wrapped with polyester tape toprevent electrical contact with adjacent pairs, triples or quads.Individually shielded pairs, triples or quads are laid up in concentric layers andwrapped with a PETP tape.Pairs, triples, or quads are identified by numbers printed directly on theinsulated conductors.Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compoundTape over innercoveringPET tape + rubberized Polyamide tapeArmour/screen C Galvanized steel wire braidTape over armour/screenPET tape + rubberised Polyamide tapeOuter sheathU Flame retardant, halogen-free, enhanced oil-resisting thermoset compound(LSF), SW4 to BS 7655 section 2.6Marking text"metre mark" "year" "DRAKA" "BFCU(I)" "UKOOA code" "150/250V""number of pair, triples or quads" "conductor size" "BS7917" “IEC60331-21”"IEC60332-3-22" (marking may differ on cable actually supplied)Outer sheath colour Grey or BlueConstructionCore identificationPair - Black—White, numbered 1-1, 2-2, 3-3 ……Triple— Black—White—Red, numbered 1-1-1, 2-2-2, 3-3-3 ……Quad— Black—White—Red—Blue, numbered 1-1-1-1, 2-2-2-2 …..Each core is identified by contrasting numerals & words repeatedalong the whole length of the cable.www.drakaMOG.comInformation subject to change without notice
  28. 28. Marine, Oil & Gas27www.drakaMOG.comInformation subject to change without noticeBFCU(I) 250V, Fire Resistant, Individual screened instrumentationRange and dimensionsNumberofelementsNo ofcores inelementCrosssectioncore, mm²ConductorDiameter,mmInsulationThicknessmmThicknessInnerSheath,mmApproxDiameterInnerSheath,mmDiameterBraidWire, mmThicknessOuterSheath,mmApproxOverallDiametermmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)1 2 0.75 1.15 0.8 1 8 0.3 1.2 12 260 181 4 0.75 1.15 0.8 1.2 10 0.3 1.3 14 330 311 3 0.75 1.15 0.8 1 8.5 0.3 1.2 12.5 280 253 3 0.75 1.15 0.8 1.3 14.5 0.3 1.5 19 590 737 3 0.75 1.15 0.8 1.5 20 0.3 1.7 24.5 990 17112 3 0.75 1.15 0.8 1.7 26.5 0.45 2 32.5 1640 2931 2 0.75 1.15 0.8 1 8 0.3 1.2 12 245 181 4 0.75 1.15 0.8 1.2 10 0.3 1.3 14 330 311 3 0.75 1.15 0.8 1 8.5 0.3 1.2 12.5 280 253 3 0.75 1.15 0.8 1.3 14.5 0.3 1.5 19 590 737 3 0.75 1.15 0.8 1.5 20 0.3 1.7 24.5 990 17112 3 0.75 1.15 0.8 1.7 26.5 0.45 2 32.5 1640 2931 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 300 321 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 571 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 300 321 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 571 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 330 451 2 1 1.3 0.8 1 8.5 0.3 1.2 12.5 270 241 2 1 1.3 0.8 1 8.5 0.3 1.2 12.5 270 247 2 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 800 1241 3 1 1.3 0.8 1.1 9 0.3 1.2 13 310 321 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 330 457 2 1.5 1.6 0.8 1.5 20.5 0.3 1.7 25 1030 2227 2 1.5 1.6 0.8 1.5 20.5 0.3 1.7 25 1030 2222 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18.5 500 641 4 1 1.3 0.8 1.2 10 0.3 1.4 14.5 360 411 4 1 1.3 0.8 1.2 10 0.3 1.4 14.5 360 411 3 1 1.3 0.8 1.1 9 0.3 1.2 13 310 327 2 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 800 12420 2 0.75 1.15 0.8 1.9 30 0.45 2.1 36.5 2040 3541 4 2.5 2 0.8 1.3 12 0.3 1.5 16.5 500 1003 2 0.75 1.15 0.8 1.2 13.5 0.3 1.4 17.5 480 533 2 1 1.3 0.8 1.3 14 0.3 1.4 18.5 520 713 2 0.75 1.15 0.8 1.2 13.5 0.3 1.4 17.5 480 53
  29. 29. Marine, Oil & Gas28www.drakaMOG.comInformation subject to change without noticeBFCU(I) 250V, Fire Resistant, Individual screened instrumentation12 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 21320 2 0.75 1.15 0.8 1.9 30 0.45 2.1 36.5 2040 3545 2 0.75 1.15 0.8 1.3 16 0.3 1.5 20.5 660 893 2 1.5 1.6 0.8 1.3 15 0.3 1.5 19.5 600 965 2 0.75 1.15 0.8 1.3 16 0.3 1.5 20.5 660 8920 2 1.5 1.6 0.8 2 34 0.45 2.3 41 2640 6361 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 575 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 840 1595 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 840 15912 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 2132 2 0.75 1.15 0.8 1.2 12.5 0.3 1.4 17 430 362 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18.5 500 642 2 0.75 1.15 0.8 1.2 12.5 0.3 1.4 17 430 362 3 0.75 1.15 0.8 1.3 14 0.3 1.4 18 490 492 3 1 1.3 0.8 1.3 14.5 0.3 1.5 19 530 652 3 1.5 1.6 0.8 1.3 15.5 0.3 1.5 20 600 893 3 1 1.3 0.8 1.3 15.5 0.3 1.5 20 630 973 3 1.5 1.6 0.8 1.4 16.5 0.3 1.5 21 730 1343 2 1 1.3 0.8 1.3 14 0.3 1.4 18.5 520 713 2 1.5 1.6 0.8 1.3 15 0.3 1.5 19.5 600 9612 2 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1750 38212 2 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1750 38220 2 1.5 1.6 0.8 2 34 0.45 2.3 41 2640 636NumberofelementsNo ofcores inelementCrosssectioncore, mm²ConductorDiameter,mmInsulationThicknessmmThicknessInnerSheath,mmApproxDiameterInnerSheath,mmDiameterBraidWire, mmThicknessOuterSheath,mmApproxOverallDiametermmWeight ofCableApprox.(Kg/Km)CoppercontentApprox.(kg/km)TypeCapacitance,approx. (nF/km)Inductance,approx (mH/km)Resistance at 20°C, max. (Ohm/km)L/R ratio, (microH/Ohm)Insulationresistance(MinimumMOhmx km)Shielded pair 0,75 mm² 90 0,75 26,7 14 940Shielded triple 0,75 mm² 90 0,75 26,7 14 940Shielded quad 0,75 mm² 60 0,91 26,7 14 940Shielded pair 1 mm² 100 0,73 20,0 18 840Shielded triple 1 mm² 100 0,73 20,0 18 840Shielded quad 1 mm² 70 0,95 20,0 18 840Shielded pair 1,5 mm² 110 0,68 13,7 24,8 730Shielded triple 1,5 mm² 110 0,68 13,7 24,8 730Shielded quad 1,5 mm² 80 0,99 13,7 24,8 730Shielded pair 2,5 mm² 120 0,70 7,56 46,3 620Electrical values
  30. 30. Marine, Oil & Gas29www.drakaMOG.comInformation subject to change without noticeBFCU(I) 250V, Fire Resistant, Individual screened instrumentationOrdering informationPart number Description Sheath Colour Design standard UKOOA Code840009 BFCU(I) 250V 1PAIR 0.75mm² GREY BS 7917 : 1999 GPF00840010 BFCU(I) 250V 1QUAD 0.75mm² GREY BS 7917 : 1999 GPX00840017 BFCU(I) 250V 1TRIP 0.75mm² GREY BS 7917 : 1999 GPR00840018 BFCU(I) 250V 3TRIP 0.75mm² GREY BS 7917 : 1999 GPS00840019 BFCU(I) 250V 7TRIP 0.75mm² GREY BS 7917 : 1999 GPT00840020 BFCU(I) 250V 12TRIP 0.75mm² GREY BS 7917 : 1999 GPU00840029 BFCU(I) 250V 1PAIR 0.75mm² BLUE BS 7917 : 1999 GMF00840030 BFCU(I) 250V 1QUAD 0.75mm² BLUE BS 7917 : 1999 GMX00840037 BFCU(I) 250V 1TRIP 0.75mm² BLUE BS 7917 : 1999 GMR00840038 BFCU(I) 250V 3TRIP 0.75mm² BLUE BS 7917 : 1999 GMS00840039 BFCU(I) 250V 7TRIP 0.75mm² BLUE BS 7917 : 1999 GMT00840040 BFCU(I) 250V 12TRIP 0.75mm² BLUE BS 7917 : 1999 GMU00840041 BFCU(I) 250V 1PAIR 1.5mm² GREY BS 6883 : 1991 GPF02840042 BFCU(I) 250V 1QUAD 1.5mm² GREY BS 6883 : 1991 GPX02840045 BFCU(I) 250V 1PAIR 1.5mm² BLUE BS 6883 : 1991 GMF02840046 BFCU(I) 250V 1QUAD 1.5mm² BLUE BS 6883 : 1991 GMX02840087 BFCU(I) 250V 1TRIP 1.5mm² BLUE BS 6883 : 1991 GMR02840089 BFCU(I) 250V 1PAIR 1mm² BLUE BS 7917 : 1999 GMF01840123 BFCU(I) 250V 1PAIR 1mm² GREY BS 7917 : 1999 GPF01840125 BFCU(I) 250V 7PAIR 0.75mm² GREY BS 7917 : 1999 GPJ00840127 BFCU(I) 250V 1TRIP 1mm² GREY BS 7917 : 1999 GPR01840131 BFCU(I) 250V 1TRIP 1.5mm² GREY BS 6883 : 1991 GPR02840138 BFCU(I) 250V 7PAIR 1.5mm² GREY BS 6883 : 1991 GPJ02840139 BFCU(I) 250V 7PAIR 1.5mm² BLUE BS 6883 : 1991 GMJ02840140 BFCU(I) 250V 2PAIR 1.5mm² BLUE BS 6883 : 1991 -840141 BFCU(I) 250V 1QUAD 1mm² GREY BS 7917 : 1999 GPX01840142 BFCU(I) 250V 1QUAD 1mm² BLUE BS 7917 : 1999 GMX01840157 BFCU(I) 250V 1TRIP 1mm² BLUE BS 7917 : 1999 GMR01840175 BFCU(I) 250V 7PAIR 0.75mm² BLUE BS 7917 : 1999 GMJ00840200 BFCU(I) 250V 20PAIR 0.75mm² GREY BS 7917 : 1999 GPL00840202 BFCU(I) 250V 1QUAD 2.5mm² GREY BS 6883 : 1991 GPX03840217 BFCU(I) 250V 3PAIR 0.75mm² BLUE BS 7917 : 1999 GMH00840218 BFCU(I) 250V 3PAIR 1mm² GREY BS 7917 : 1999 GPH01840240 BFCU(I) 250V 3PAIR 0.75mm² GREY BS 7917 : 1999 GPH00840253 BFCU(I) 250V 12PAIR 0.75mm² GREY BS 7917 : 1999 GPK00840254 BFCU(I) 250V 20PAIR 0.75mm² BLUE BS 7917 : 1999 GML00840267 BFCU(I) 250V 5PAIR 0.75mm² BLUE BS 6883 : 1991 -840268 BFCU(I) 250V 3PAIR 1.5mm² GREY BS 6883 : 1991 GPH02840271 BFCU(I) 250V 5PAIR 0.75mm² GREY BS 6883 : 1991 -840280 BFCU(I) 250V 20PAIR 1.5mm² GREY BS 6883 : 1991 GPL02840281 BFCU(I) 250V 1QUAD 1.5mm² GREY BS 6883 : 1991 GPX02840290 BFCU(I) 250V 5PAIR 1.5mm² GREY BS 6883 : 1991 -840291 BFCU(I) 250V 5PAIR 1.5mm² BLUE BS 6883 : 1991 -
  31. 31. Marine, Oil & Gas30www.drakaMOG.comInformation subject to change without noticeBFCU(I) 250V, Fire Resistant, Individual screened instrumentationPart number Description Sheath Colour Design standard UKOOA Code840292 BFCU(I) 250V 12PAIR 0.75mm² BLUE BS 7917 : 1999 GMK00840314 BFCU(I) 250V 2PAIR 0.75mm² GREY BS 6883 : 1991 -840315 BFCU(I) 250V 2PAIR 1.5mm² GREY BS 6883 : 1991 -840316 BFCU(I) 250V 2PAIR 0.75mm² BLUE BS 6883 : 1991 -840322 BFCU(I) 250V 2TRIP 0.75mm² GREY BS 6883 : 1991 -840323 BFCU(I) 250V 2TRIP 1mm² GREY BS 6883 : 1991 -840324 BFCU(I) 250V 2TRIP 1.5mm² GREY BS 6883 : 1991 -840325 BFCU(I) 250V 3TRIP 1mm² GREY BS 7917 : 1999 GPS01840326 BFCU(I) 250V 3TRIP 1.5mm² GREY BS 6883 : 1991 GPS02840327 BFCU(I) 250V 3PAIR 1mm² BLUE BS 7917 : 1999 GMH01840328 BFCU(I) 250V 3PAIR 1.5mm² BLUE BS 6883 : 1991 GMH02840329 BFCU(I) 250V 12PAIR 1.5mm² GREY BS 6883 : 1991 GPK02840330 BFCU(I) 250V 12PAIR 1.5mm² BLUE BS 6883 : 1991 GMK02840331 BFCU(I) 250V 20PAIR 1.5mm² BLUE BS 6883 : 1991 GML02Minimum Bending Radius duringInstallationMinimum Bending Radius FixedInstalledMaximum Tensile Load DuringInstallationMinimum InstallationTemperature10 x D 8 x D 50 N /mm² -20°CInstallation recommendations
  32. 32. Marine, Oil & Gas31www.drakaMOG.comInformation subject to change without noticeUKOOA Cable coding1stCharacterType Voltage Type VoltageF Fire resistant, reduced halogen 150/250V M Flame retardant, reduced halogen 3.8/6.6kVG Fire resistant, low smoke and fume 150/250V N Flame retardant, reduced halogen 1.9/3.3kVH Flame retardant, reduced halogen 8.7/15kV P Flame retardant, reduced halogen 6.35/11kVJ Flame retardant, reduced halogen 150/250V W Flame retardant, low smoke and fume 600/1000VK Flame retardant, low smoke and fume 150/250V X Fire resistant, reduced halogen 600/1000VL Flame retardant, reduced halogen 600/1000V Y Fire resistant, low smoke and fume 600/1000V2ndCharacterBasic construction Sheath colour Armour ScreenA Flame retardant Black (600/1000V), Red (HV) Bronze braidB Flame retardant Black (600/1000V), Red (HV) GSWBC Fire resistant Black (600/1000V) Bronze braidD Fire resistant Black (600/1000V) GSWBE Flame retardant Green/Yellow NoneF Flame retardant Black NoneG Flame retardant Light Blue GSWB CollectiveH Flame retardant Light Blue GSWB IndividualJ Flame retardant Grey GSWB CollectiveK Flame retardant Grey GSWB IndividualL Fire resistant Light Blue GSWB CollectiveM Fire resistant Light Blue GSWB IndividualN Fire resistant Grey GSWB CollectiveP Fire resistant Grey GSWB IndividualY Flame retardant Orange GSWB Co-axial3rdCharacter1 Single core B 19 core K 12 pair T 7 triple2 2 core C 27 core L 20 pair U 12 triple3 3 core D 37 core M 27 pair X 1 quad4 4 core F 1 pair N 37 pair Y 3 quad7 7 core H 3 pair R 1 triple Z 7 quadA 12 core J 7 pair S 3 triple4th& 5thCharacter00 0.75 mm² Flexible (class 5) stranded tinned copper cores 50 50 mm² Stranded tinned copper cores01 1.0 mm² Flexible (class 5) stranded tinned copper cores 70 70 mm² Stranded tinned copper cores02 1.5 mm² Flexible (class 5) stranded tinned copper cores 95 95 mm² Stranded tinned copper cores03 2.5 mm² Stranded tinned copper cores 0A 120 mm² Stranded tinned copper cores04 4 mm² Stranded tinned copper cores 0B 150 mm² Stranded tinned copper cores05 4 mm² Stranded tinned copper cores 0C 185 mm² Stranded tinned copper cores06 6 mm² Stranded tinned copper cores 0D 240 mm² Stranded tinned copper cores10 10 mm² Stranded tinned copper cores 0E 300 mm² Stranded tinned copper cores16 16 mm² Stranded tinned copper cores 0F 400 mm² Stranded tinned copper cores25 25 mm² Stranded tinned copper cores 0G 500 mm² Stranded tinned copper cores35 35 mm² Stranded tinned copper cores 0H 630 mm² Stranded tinned copper cores
  33. 33. Marine, Oil & Gas32www.drakaMOG.comInformation subject to change without noticeTechnical informationCONDUCTOR RESISTANCEIn accordance with BS 6360, class 2 (IEC 228,class2.)Nominal conductor No. of strands Maximum resistance per km ( ohm )area ( mm² ) n x mmØ 20 °C 90 °C1,5 7 x 0,53 12,2 15,32,5 7 x 0,67 7,56 9,644 7 x 0,85 4,7 5,996 7 x 1,05 3,11 3,9710 7 x 1,35 1,84 2,3516 7 x 1,71 1,16 1,4825 7 x 2,15 0,734 0,93635 19 x 1,53 0,529 0,67550 19 x 1,80 0,391 0,49970 19 x 2,17 0,270 0,34495 37 x 1,80 0,195 0,249120 37 x 2,03 0,154 0,196150 37 x 2,27 0,126 0,161185 37 x 2,52 0,100 0,128240 61 x 2,24 0,0762 0,0972300 61 x 2,52 0,0607 0,0774In accordance with BS 6360, class 5— Flexible tinned conductors for instrumentation and multicore cablesNominal conductor No. of strands Maximum resistance per km( ohm )area ( mm² ) n x mmØ 20 °C 90 °C0,75 21 x 0,21 26,7 34,181,0 27 x 0,21 20,0 25,61,5 26 x 0,26 13,7 17,54
  34. 34. Marine, Oil & Gas33www.drakaMOG.comInformation subject to change without noticeTechnical informationINSTALLATION RECOMMENDATIONSThe following installation recommendations are inaccordance with British Standard 6883:1999, appendix B.Installation temperature.Minimum recommended installation temperature for cablesaccording to BS 6883 is -15°C.Minimum cable bending radius.The cables specified in accordance with BS 6883 should not be bent to a radius smaller than that specified in thetable below. Wherever possible, larger installation radii should be used. In the case of radial field cables the bendradii specified in the table below are applicable to bends made without the use of a former. Where the bend iscarefully controlled using a former, the minimum radii can be reduced to 12D in the case of three-core cables and15D for single-core cables.Type of cable Overall diameter Minimum bending radiusScreened multipair, triple and quad Any 8xDMulticore unarmoured (unbraided) 600/1000 V ≤10 mm>10 mm to ≤25 mm>25 mm3xD4xD6xDMulticore wire braided 600/1000 V ≤25 mm>25 mm4xD6xDWire braided 1900/3300 V,3300/3300 VAny 6xDNon-radial field wire braided 3800/6600 V,6600/6600 V and 6350/11000 VAny 12xDRadial field wire braided 3800/6600 V,6350/11000 Vand 8700/15000 V cablesAll single-corecables20xDAll three-core cables 15xDWhere “D” is the overall diameter of the cable
  35. 35. Marine, Oil & Gas34www.drakaMOG.comInformation subject to change without noticeTechnical informationVoltage test after installationVoltage tests after installation are not a requirement of this standard. If performed, the test should be made withdirect current at the voltage in the table below after all terminating and jointinghas been carried out but before before connection to the system. The voltage should be increased gradually to thefull value and maintained continuously for 15 min between either:(a) the conductor and the screen in case of screened cores; or(b) each conductor and all the other conductors and braid, if any, inthe case of unscreened cores.Voltage tests after installationRated voltage U0 Test voltage d.ckV0,150,61,93,33,86,356,68,7kV2,56111818252537Installations pulling tension(Not specified in BS 6883)The cable pulling tension during installation can be estimated by means of the following formula:P = 5 kp x total cross section of conductorsin the armoured cable.orP = 2,5 kp x total cross section of conductorsin the unarmoured cable.Additional tension will be supplied from the braid and the insulation and sheathing compound.Storage conditions(Not specified in BS 6883)Extended storage conditions on the site can be estimated to at least two years.The cable‑ends always have to be sealed to stop ingress of moisture. One turn of the cable have to be scrapped ifthe cable end not have been sealed.
  36. 36. Marine, Oil & Gas35www.drakaMOG.comInformation subject to change without noticeTechnical informationVoltage drop / RFCU 0.6/1kV 90°C 50 HzValues of voltage drop for three phase circuit are tabulated with different power factors (cos"fi")Conductor area, mm² Voltage drop, (V/A*km) R at 90°C X at 50HzPowerfactor 0,2 0,3 0,5 0,7 0,8 0,9 11,5 5,440 8,160 13,60 19,05 21,78 24,52 27,30 15,6 0,1032,5 3,373 5,060 8,44 11,82 13,51 15,21 16,96 9,64 0,0964 2,108 3,163 5,27 7,39 8,45 9,52 10,64 5,99 0,0966 1,407 2,110 3,52 4,93 5,65 6,36 7,12 3,97 0,09010 0,843 1,265 2,11 2,96 3,39 3,83 4,30 2,35 0,08416 0,541 0,811 1,35 1,90 2,18 2,46 2,78 1,48 0,08025 0,352 0,528 0,88 1,24 1,42 1,61 1,84 0,936 0,07935 0,260 0,391 0,65 0,92 1,06 1,20 1,38 0,675 0,07650 0,199 0,299 0,50 0,71 0,81 0,93 1,07 0,499 0,07670 0,145 0,218 0,37 0,52 0,60 0,68 0,80 0,344 0,07595 0,112 0,168 0,28 0,40 0,46 0,53 0,63 0,249 0,073120 0,093 0,140 0,24 0,33 0,39 0,45 0,54 0,196 0,072150 0,081 0,122 0,20 0,29 0,34 0,39 0,47 0,161 0,072185 0,069 0,105 0,18 0,25 0,29 0,34 0,42 0,128 0,072240 0,059 0,089 0,15 0,21 0,25 0,29 0,36 0,0972 0,072300 0,052 0,078 0,13 0,19 0,22 0,26 0,33 0,0774 0,071Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15Voltage drop / RFCU 0.6/1kV 90°C 60 HzValues of voltage drop for three phase circuit are tabulated with different power factors (cos"fi")Conductor area, mm² Voltage drop, (V/A*km) R at 90°C X at 60HzPowerfactor 0,2 0,3 0,5 0,7 0,8 0,9 11,5 5,447 8,171 13,62 19,08 21,81 24,56 27,35 15,6 0,1232,5 3,380 5,070 8,45 11,84 13,54 15,25 17,01 9,64 0,1154 2,115 3,173 5,29 7,42 8,48 9,56 10,69 5,99 0,1156 1,413 2,120 3,54 4,96 5,67 6,40 7,17 3,97 0,10810 0,849 1,274 2,13 2,98 3,42 3,86 4,35 2,35 0,10116 0,546 0,820 1,37 1,92 2,20 2,49 2,82 1,48 0,09625 0,357 0,536 0,90 1,26 1,45 1,64 1,88 0,936 0,09535 0,266 0,399 0,67 0,94 1,08 1,23 1,42 0,675 0,09250 0,205 0,308 0,52 0,73 0,84 0,96 1,11 0,499 0,09270 0,151 0,227 0,38 0,54 0,62 0,71 0,84 0,344 0,09195 0,117 0,176 0,30 0,42 0,49 0,56 0,67 0,249 0,088120 0,098 0,147 0,25 0,35 0,41 0,47 0,57 0,196 0,086150 0,086 0,130 0,22 0,31 0,36 0,42 0,52 0,161 0,087185 0,074 0,112 0,19 0,27 0,32 0,37 0,46 0,128 0,086240 0,064 0,096 0,16 0,23 0,27 0,32 0,40 0,0972 0,086300 0,057 0,086 0,15 0,21 0,25 0,29 0,37 0,0774 0,086Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15
  37. 37. Marine, Oil & Gas36www.drakaMOG.comInformation subject to change without noticeTechnical informationVoltage drop / BFCU 0.6/1kV 90°C 50 HzValues of voltage drop for three phase circuit are tabulated with different power factors (cos"fi")Conductor area, mm² Voltage drop, (V/A*km) R at 90°C X at 50HzPowerfactor 0.2 0.3 0.5 0.7 0.8 0.9 11.5 5.442 8.163 13.608 19.059 21.789 24.527 27.314 15.6 0.1082.5 3.375 5.062 8.440 11.824 13.520 15.223 16.972 9.64 0.1014 2.110 3.165 5.278 7.397 8.461 9.531 10.647 5.99 0.16 1.408 2.112 3.523 4.940 5.652 6.371 7.132 3.97 0.09410 0.845 1.268 2.115 2.967 3.398 3.834 4.310 2.35 0.08816 0.541 0.812 1.356 1.905 2.182 2.466 2.787 1.48 0.08225 0.352 0.529 0.884 1.244 1.427 1.616 1.842 0.936 0.08135 0.261 0.392 0.655 0.923 1.061 1.204 1.381 0.675 0.07850 0.200 0.300 0.503 0.710 0.817 0.929 1.077 0.499 0.07870 0.145 0.218 0.366 0.518 0.597 0.682 0.800 0.344 0.07595 0.112 0.169 0.284 0.403 0.465 0.534 0.635 0.249 0.075120 0.093 0.140 0.236 0.336 0.389 0.447 0.538 0.196 0.073150 0.081 0.122 0.206 0.293 0.340 0.393 0.477 0.161 0.073185 0.070 0.105 0.177 0.253 0.295 0.341 0.420 0.128 0.073240 0.059 0.089 0.149 0.215 0.250 0.291 0.364 0.0972 0.072300 0.052 0.078 0.132 0.191 0.223 0.260 0.330 0.0774 0.072Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15Voltage drop / BFCU 0.6/1kV 90°C 60 HzValues of voltage drop for three phase circuit are tabulated with different power factors (cos"fi")Conductor area, mm² Voltage drop, (V/A*km) R at 90°C X at 60HzPowerfactor 0.2 0.3 0.5 0.7 0.8 0.9 11.5 5.449 8.175 13.628 19.089 21.825 24.570 27.374 15.6 0.132.5 3.382 5.073 8.458 11.850 13.552 15.262 17.026 9.64 0.1214 2.117 3.176 5.296 7.424 8.493 9.570 10.701 5.99 0.126 1.414 2.122 3.540 4.964 5.681 6.406 7.181 3.97 0.11210 0.851 1.277 2.130 2.990 3.425 3.867 4.356 2.35 0.10516 0.547 0.821 1.372 1.927 2.210 2.499 2.833 1.48 0.09925 0.358 0.538 0.899 1.265 1.453 1.647 1.885 0.936 0.09735 0.267 0.400 0.670 0.945 1.086 1.235 1.425 0.675 0.09450 0.205 0.308 0.516 0.730 0.841 0.958 1.117 0.499 0.09370 0.151 0.226 0.380 0.538 0.621 0.711 0.841 0.344 0.0995 0.118 0.177 0.297 0.423 0.490 0.563 0.676 0.249 0.09120 0.099 0.148 0.250 0.356 0.413 0.476 0.579 0.196 0.088150 0.086 0.130 0.219 0.313 0.364 0.422 0.518 0.161 0.088185 0.075 0.113 0.191 0.273 0.319 0.370 0.461 0.128 0.088240 0.064 0.096 0.163 0.235 0.274 0.320 0.405 0.0972 0.087300 0.057 0.086 0.145 0.209 0.245 0.287 0.368 0.0774 0.086Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15
  38. 38. Marine, Oil & Gas37www.drakaMOG.comInformation subject to change without noticeTechnical informationCODE DESIGNATIONEPR - Ethylene Propylene Rubber insulationAccording to BS 7655 (section 1.2) , type GP4MGT - Mica Glass TapeEPR - Inner covering, flame retardant halogen-free EP-rubber based compoundGSWB - Galvanized Steel wire BraidPBWB - Phosphore Bronze Wire BraidLSF - Flame retardant, halogen-free, enhanced oil-resisting and mud resistant thermoset compoundIn accordance with BS 7655 Section 2.6 type SW4Materials 1.Letter:Insulation2.Letter:Bedding/Sheath3.Letter:Braid/Armour4.Letter:Outher SheathMica/EPR- insulation BEPR- insulation REPR- based bedding FGalvanized Steel Wire Braid CPhosphor bronze wire PLSF U UAdditional abbreviation for instrumentation cables:Collective screen cable............................ (c)Individual pair/triple screened cable........... (i)
  39. 39. Other catalogues available on request:NEK606 Offshore CablesRFOU 0.6/1kvBFOU 0.6/1kvRFOU 6/10(12)kvRFOU 8.7/15kvRFOU 12/20(24)kvRFOU(C) & RFOU(I) 250vBFOU(C) & BFOU(I) 250vUX EarthRU 0.6/1kvBU 0.6/1kvQFCI Fire Resistant Armoured Fibre OpticsBostrig Type P IEEE Rig CablesPowerControlSignalArmoured & UnarmouredMarine Fibre OpticsVFD Type PBostmarine CablesPowerControlSignalShipline Marine CablesTI 0.6/1kvTI(C) 0.6/1kvTXOI 0.6/1kvTXOI 250vBI 0.6/1kvBI(C) 250vBI(I) 250vBXOI 0.6/1kvBXOI 250vBXOI(I) 250vTFOI 6/10(12)kvShipline Plus Marine CablesHUSK—TFXI 0.6/1kvHUSO—TIOI 0.6/1kvHUCOM TIOI(C) 250vMarine, Oil & Gaswww.drakaMOG.comInformation subject to change without notice
  40. 40. Marine, Oil & GasUnit 3, Peterseat Drive, Peterseat ParkAltens Industrial Estate,Aberdeen AB12 3HTUKTel: +44 (0) 1224 244 800Fax: + 44 (0) 1224 249 839Fax to Email: +44 (0) 8704 580 303Email: us-uksales@draka.comwww.drakaMOG.comBS/UKOOACAT07/2008

×