The Bomb in Your Home Needs Your Attention!
                             By Stephen Ruback, Professional Inspector        [TREC license 6030]               page 1 of 2

    Not the icon of doom that shows          A common water heater tank size         blow, they will be spewing boiling
up on your computer at the worst          is 50 gallons, so the pressure in that     water full blast. As the water heater
possible time – this is the real thing.   one gallon air space, at boiling,          keeps heating, they will keep
You just haven’t recognized it            would rise to more than 900,000 psi,       spewing. Wouldn’t it be handy if
because it’s been disguised as a          if the tank were strong enough. It         that boiling water was directed
water heater.                             would have to be a really super            outside to a visible location that
    Remember that cylindrical thing       strong tank to hold that kind of           didn’t cause damage? Well, they are
hidden away in some corner, closet        pressure. Better than that – there’s       supposed to be, but not all are. You
or attic that magically converts the      no air space at all in your water          may wish to check yours.
cool, incoming water to a nice hot        heater. That means the pressure                The valve is sized to discharge
bath or shower? That’s it. Some           potential is infinite, but lets just say   enough hot water from the tank, to
folks even have two of them.              that it’s greater than trillions of        keep the tank from overheating by
    Let’s think a little smaller for a    pounds per square inch! No tank in         pulling in cool water from the
moment. When you heat a few cups          the known universe could hold back         supply line. If the pipe is blocked,
of water in a pot, or teakettle. Once     that kind of pressure. In short, if the    restricted or too small, we’re back to
that water is boiling, what could         thermostat gets tired, falls asleep,       the bomb. The discharge pipe for the
happen if it spilled? Could that be       quits or dies on the job, your water       PT valve is not supposed to be
dangerous or harmful? Of course.          heater will keep on heating –              smaller than the size of the opening
    Now, enlarge the picture. Water       without other intervention – quickly       on the valve [typically 3/4 copper or
is rather compact, weighing in at         becoming a 300 - 400 pound bomb.           galvanized pipe]. If it is, your flow
about 8.2 pounds per gallon. If you          Water heaters do blow up –              is restricted. Elbows restrict flow.
convert that measly single gallon of      spectacularly! They can make like a        More than four, and you and your
water to a gas [steam], it will insist    rocket and land down the street.           family are definitely at risk. Uphill
on taking up more than 1250 gallons       They can level a house. It’s               flow allows water to collect in the
of space. Your water heater tank          happened a lot. The death toll is          pipe. When it blows, that water can
doesn’t have anywhere near that           real. It’s not a pretty thought. That’s    act like a plug – kaboom. Keep that
kind of room inside, and it’s already     why an enterprising fellow, back in        drain line running down, all the way
busy, holding 40 or 50 gallons of         the 40’s invented a low cost device        to the end.
water. Turning all 40 gallons into        to prevent these catastrophes. It’s            Your PT valve should have a
steam would demand more than              called a Temperature & Pressure [or        dedicated drain line. That is a line
50,000 gallons of space. This could       Pressure/Temperature] relief valve.        not connected to the drip pan or any
be a problem.                             That’s your T&P or PT valve for            other line, and going directly to a
    What would happen if the              short. If your thermostat fails and        safe and visible location [preferably
thermostat died and the heater went       the PT valve doesn’t do its job or is      outside]. Any deviation from this
into full-time on mode? A typical         improperly installed, we are back to       can cause serious problems.
electric water heater would reach         square one with a very real, live              For it to work, the temperature
full boiling temperature in little        bomb in the house. It’s because of         sensor inside must extend into the
more than two hours. A typical gas        the PT valves, and short water             tank several inches. When it is
heater     would      reach    boiling    heater life spans, that we don’t hear      installed in a pipe outside of the
temperature in less than an hour.         much in the news about water heater        tank, it won’t work. Be sure yours is
    Let’s look briefly at how big a       explosions these days.                     installed in the right place for your
problem that might be. Just for               Thermostats are sealed units with      tank. That’s directly on top, or on
illustration, consider one gallon of      no user serviceable parts inside. We       the side of the water tank. If your
water in a two gallon super strong,       are at their mercy, but PT valves are      water heater is so old it doesn’t have
sealed tank. That gives a whole           a slightly different story. They can       a PT valve port, replace it, real soon.
gallon of air space to play with.         be checked for proper installation             PT valves get old and die,
Converting that gallon of water into      and routinely checked for operation        sometimes before the water heater
steam, will raise the pressure in that       A PT valve is required for each         dies. The only way to know if one
tank to more than 18 thousand psi.        water heater, but they are not always      works is to test it. That's why there’s
[pounds per square inch].                 installed properly, and they can die       a little lever on top, so you can open
    Typical water heater tanks are        too. Yours is calling to you at this       it briefly to verify it is not stuck.
claimed to withstand as much as           very moment.                                   The valve manufacturer suggests,
150 psi. A significant portion of that       Their function is to automatically      in rather large print, the valve
pressure allowance is taken up with       open and relieve the temperature           should be tested at least once a year.
normal water pressure which               and pressure in an overheat                It’s a simple thing to do. Be sure the
typically runs more than 50 psi, but      situation,     thus     avoiding      an   drain line for your PT valve is
it gets even more interesting.            explosion.                                 directed to a safe place, and lift the
                                             That means, in an emergency             lever for a few seconds.
The Bomb in Your Home Needs Your Attention!
                             By Stephen Ruback, Professional Inspector      [TREC license 6030]               page 2 of 2

   Observe the water flow and             good to breathe, carbon monoxide         adventures can be avoided with
return the lever to its original          kills, quietly and without smell.        proper preparation, vigilance and
position. If it works, you’re OK. If it   Early trouble signs are nausea and       timely maintenance. Leaks never
won’t open, or won’t close fully,         headaches. Be sure your water            really fix themselves in the long run.
you have a bomb waiting to happen.        heater has a generous supply of             That brings up a related question.
Any      malfunction      calls    for    outside air for combustion, and that     Where is your main water shut off
replacement of the valve.                 the flue is fully vented to the          valve? Can you quickly and easily
   When you do your weekly or             outside. Those water heaters tucked      turn off your water supply before
monthly home maintenance survey           into a closet or back room suck large    your house is flooded, when you
– you do that, right? Every time you      amounts of air from your living          have an emergency leak? There is
walk by the PT valve outlet, notice       space and depend on poorly sealed        supposed to be a service supply
whether it is dribbling water. If it      house construction for that air. In      valve for every house, but a
does, it’s time for replacement, as       newer, tighter, energy efficient         surprisingly large number do not
your bomb is almost ready.                construction, inside gas water           have one. Just because you have one
                                          heaters must have a dependable           doesn’t mean it works. It’s simple to
Other Common Concerns                     source of combustion air from the        test. Close the main service valve,
   Water heaters in garages should        outside.                                 then open one faucet and see if the
be installed with their ignition              Typical life expectancy for gas      water stops flowing. If it doesn’t,
sources at least 18 inches above the      water heaters is about ten years, a      you have a problem.
floor. That’s because cars get            little more for electric. The most          If your only shutoff valve is at the
parked in garages. Cars carry             common failure mode is a leak.           meter in one of those cute plastic
gasoline, which is very flammable.        When was the last time you even          boxes near the curb, think about
Cars can leak gasoline. Gasoline          looked at your water heater? Unless      how much damage could be caused
vapors are heavier than air, so they      it’s in the garage, it is supposed to    by a runaway leak when it takes
would gather at floor level. Most         have a drip pan under it, with at        hours for the water department to
garages are open enough to allow          least a 1 inch diameter drain line,      respond to your call.
some of the vapor to escape [from a       directed to a visible location              In the case of water heaters, and
small leak], hence the 18 inch            [preferably outside]. That way,          plumbing in general, “out of sight is
height. Does this apply to electric       when [not if] it leaks, you may have     out of mind” may not be in your
heaters too? You bet. Switches            a visible warning before the flood. Is   best interest.
generate sparks, and the electric         your drip pan bigger than the               By the way, new homes always
thermostat operates a switch.             diameter of the heater to catch all      need an inspection too. Be sure of
   Gas water heaters offer additional     probable leaks? It is clear of           what you are buying, and avoid ugly
dangers. The hot combustion gasses        insulation and other debris that         surprises with a thorough home
are supposed to be directed outside       could plug the drain? Most are not.      inspection, before you close the
by the flue pipe. Right on the side of    If your water heater is in your          deal. You will save money and
each section of the pipe it says keep     garage and you have a bunch of           trouble in the long run.
at least one inch space from              stuff stored in your garage, you
flammable materials. Does wood            might appreciate having a drip pan          Stephen Ruback is a licensed
burn? Does plastic burn? Of course,       under that water heater too.             Professional Inspector; member of
so make sure nothing is too close to          Where is your shut off valve?        TAREI [Texas Association of Real
your flue pipe – like rafters, roofing    When the water heater leaks, it          Estate Inspectors] and HAR
materials, foam insulated pipes or        would be handy to be able to shut        [Houston Association of Realtors];
plastic ducts.                            off the hot water line and still be      approved by TREC [Texas Real
   If your flue pipe doesn’t specify a    able to use the cold facilities. Be      Estate Commission] as a
clearance distance, it is probably        sure you can get to that valve. Not      Professional Home Inspection
single wall type that gets even hotter    all are accessible. Even worse, some     Instructor.
and requires even more space. Such        have been installed on the output           In addition, he has earned a BS in
flue pipes are outmoded and               side which turns off the hot water       engineering from Trinity University,
considered       unsafe.     Schedule     flow to the house, but does not stop     is an author of several books and
replacement as soon as possible.          the water coming into the water          teaches a variety of self
   Gas water heaters actually have a      heater – oops.                           empowerment courses through
fire in the bottom to heat the water.         Corroded fittings, valves and        Leisure Learning. For more
This fire requires lots of air to         joints indicate a problem waiting to     information, he can be reached at
support the combustion. Inadequate        happen.      It’s    usually    more     832-489-1071.
combustion air causes generation of       convenient to have these taken care
carbon monoxide.                          of before they spring into
   While any exhaust fumes are not        emergency mode. Most plumbing

More Related Content

More from LSC-CyFair Academy for Lifelong Learning

More from LSC-CyFair Academy for Lifelong Learning (20)

Immigration
ImmigrationImmigration
Immigration
 
Land - Genealogical Research
Land - Genealogical ResearchLand - Genealogical Research
Land - Genealogical Research
 
Wills & Probate
Wills & ProbateWills & Probate
Wills & Probate
 
Genealogy Research Class - Feb 26
Genealogy Research Class - Feb 26Genealogy Research Class - Feb 26
Genealogy Research Class - Feb 26
 
Genealogy Research Class Feb 26, 2016
Genealogy Research Class   Feb 26, 2016Genealogy Research Class   Feb 26, 2016
Genealogy Research Class Feb 26, 2016
 
Colonial States Information
Colonial States InformationColonial States Information
Colonial States Information
 
Vital Records Online
Vital Records OnlineVital Records Online
Vital Records Online
 
Vital Records Search
Vital Records SearchVital Records Search
Vital Records Search
 
A Cross to Share - Spring 2016
A Cross to Share  -  Spring 2016A Cross to Share  -  Spring 2016
A Cross to Share - Spring 2016
 
Census Forms 1900-1940
Census Forms 1900-1940Census Forms 1900-1940
Census Forms 1900-1940
 
Genealogy Census and Military Records
Genealogy Census and Military RecordsGenealogy Census and Military Records
Genealogy Census and Military Records
 
Birth Death Marriage Certificates by State
Birth Death Marriage Certificates by StateBirth Death Marriage Certificates by State
Birth Death Marriage Certificates by State
 
Class 1 - Welcome
Class 1 - WelcomeClass 1 - Welcome
Class 1 - Welcome
 
Virtual campus tour cal sp16
Virtual campus tour cal sp16Virtual campus tour cal sp16
Virtual campus tour cal sp16
 
Reason and Being Human
Reason and Being HumanReason and Being Human
Reason and Being Human
 
Relativism
RelativismRelativism
Relativism
 
Brooklyn and Manhattan
Brooklyn and ManhattanBrooklyn and Manhattan
Brooklyn and Manhattan
 
Women's Self-Defense Tips
Women's Self-Defense TipsWomen's Self-Defense Tips
Women's Self-Defense Tips
 
Philosophy Class Added to Schedule
Philosophy Class Added to SchedulePhilosophy Class Added to Schedule
Philosophy Class Added to Schedule
 
Moo Shu Chicken and Vegetables
Moo Shu Chicken and VegetablesMoo Shu Chicken and Vegetables
Moo Shu Chicken and Vegetables
 

Bomb in Your House

  • 1. The Bomb in Your Home Needs Your Attention! By Stephen Ruback, Professional Inspector [TREC license 6030] page 1 of 2 Not the icon of doom that shows A common water heater tank size blow, they will be spewing boiling up on your computer at the worst is 50 gallons, so the pressure in that water full blast. As the water heater possible time – this is the real thing. one gallon air space, at boiling, keeps heating, they will keep You just haven’t recognized it would rise to more than 900,000 psi, spewing. Wouldn’t it be handy if because it’s been disguised as a if the tank were strong enough. It that boiling water was directed water heater. would have to be a really super outside to a visible location that Remember that cylindrical thing strong tank to hold that kind of didn’t cause damage? Well, they are hidden away in some corner, closet pressure. Better than that – there’s supposed to be, but not all are. You or attic that magically converts the no air space at all in your water may wish to check yours. cool, incoming water to a nice hot heater. That means the pressure The valve is sized to discharge bath or shower? That’s it. Some potential is infinite, but lets just say enough hot water from the tank, to folks even have two of them. that it’s greater than trillions of keep the tank from overheating by Let’s think a little smaller for a pounds per square inch! No tank in pulling in cool water from the moment. When you heat a few cups the known universe could hold back supply line. If the pipe is blocked, of water in a pot, or teakettle. Once that kind of pressure. In short, if the restricted or too small, we’re back to that water is boiling, what could thermostat gets tired, falls asleep, the bomb. The discharge pipe for the happen if it spilled? Could that be quits or dies on the job, your water PT valve is not supposed to be dangerous or harmful? Of course. heater will keep on heating – smaller than the size of the opening Now, enlarge the picture. Water without other intervention – quickly on the valve [typically 3/4 copper or is rather compact, weighing in at becoming a 300 - 400 pound bomb. galvanized pipe]. If it is, your flow about 8.2 pounds per gallon. If you Water heaters do blow up – is restricted. Elbows restrict flow. convert that measly single gallon of spectacularly! They can make like a More than four, and you and your water to a gas [steam], it will insist rocket and land down the street. family are definitely at risk. Uphill on taking up more than 1250 gallons They can level a house. It’s flow allows water to collect in the of space. Your water heater tank happened a lot. The death toll is pipe. When it blows, that water can doesn’t have anywhere near that real. It’s not a pretty thought. That’s act like a plug – kaboom. Keep that kind of room inside, and it’s already why an enterprising fellow, back in drain line running down, all the way busy, holding 40 or 50 gallons of the 40’s invented a low cost device to the end. water. Turning all 40 gallons into to prevent these catastrophes. It’s Your PT valve should have a steam would demand more than called a Temperature & Pressure [or dedicated drain line. That is a line 50,000 gallons of space. This could Pressure/Temperature] relief valve. not connected to the drip pan or any be a problem. That’s your T&P or PT valve for other line, and going directly to a What would happen if the short. If your thermostat fails and safe and visible location [preferably thermostat died and the heater went the PT valve doesn’t do its job or is outside]. Any deviation from this into full-time on mode? A typical improperly installed, we are back to can cause serious problems. electric water heater would reach square one with a very real, live For it to work, the temperature full boiling temperature in little bomb in the house. It’s because of sensor inside must extend into the more than two hours. A typical gas the PT valves, and short water tank several inches. When it is heater would reach boiling heater life spans, that we don’t hear installed in a pipe outside of the temperature in less than an hour. much in the news about water heater tank, it won’t work. Be sure yours is Let’s look briefly at how big a explosions these days. installed in the right place for your problem that might be. Just for Thermostats are sealed units with tank. That’s directly on top, or on illustration, consider one gallon of no user serviceable parts inside. We the side of the water tank. If your water in a two gallon super strong, are at their mercy, but PT valves are water heater is so old it doesn’t have sealed tank. That gives a whole a slightly different story. They can a PT valve port, replace it, real soon. gallon of air space to play with. be checked for proper installation PT valves get old and die, Converting that gallon of water into and routinely checked for operation sometimes before the water heater steam, will raise the pressure in that A PT valve is required for each dies. The only way to know if one tank to more than 18 thousand psi. water heater, but they are not always works is to test it. That's why there’s [pounds per square inch]. installed properly, and they can die a little lever on top, so you can open Typical water heater tanks are too. Yours is calling to you at this it briefly to verify it is not stuck. claimed to withstand as much as very moment. The valve manufacturer suggests, 150 psi. A significant portion of that Their function is to automatically in rather large print, the valve pressure allowance is taken up with open and relieve the temperature should be tested at least once a year. normal water pressure which and pressure in an overheat It’s a simple thing to do. Be sure the typically runs more than 50 psi, but situation, thus avoiding an drain line for your PT valve is it gets even more interesting. explosion. directed to a safe place, and lift the That means, in an emergency lever for a few seconds.
  • 2. The Bomb in Your Home Needs Your Attention! By Stephen Ruback, Professional Inspector [TREC license 6030] page 2 of 2 Observe the water flow and good to breathe, carbon monoxide adventures can be avoided with return the lever to its original kills, quietly and without smell. proper preparation, vigilance and position. If it works, you’re OK. If it Early trouble signs are nausea and timely maintenance. Leaks never won’t open, or won’t close fully, headaches. Be sure your water really fix themselves in the long run. you have a bomb waiting to happen. heater has a generous supply of That brings up a related question. Any malfunction calls for outside air for combustion, and that Where is your main water shut off replacement of the valve. the flue is fully vented to the valve? Can you quickly and easily When you do your weekly or outside. Those water heaters tucked turn off your water supply before monthly home maintenance survey into a closet or back room suck large your house is flooded, when you – you do that, right? Every time you amounts of air from your living have an emergency leak? There is walk by the PT valve outlet, notice space and depend on poorly sealed supposed to be a service supply whether it is dribbling water. If it house construction for that air. In valve for every house, but a does, it’s time for replacement, as newer, tighter, energy efficient surprisingly large number do not your bomb is almost ready. construction, inside gas water have one. Just because you have one heaters must have a dependable doesn’t mean it works. It’s simple to Other Common Concerns source of combustion air from the test. Close the main service valve, Water heaters in garages should outside. then open one faucet and see if the be installed with their ignition Typical life expectancy for gas water stops flowing. If it doesn’t, sources at least 18 inches above the water heaters is about ten years, a you have a problem. floor. That’s because cars get little more for electric. The most If your only shutoff valve is at the parked in garages. Cars carry common failure mode is a leak. meter in one of those cute plastic gasoline, which is very flammable. When was the last time you even boxes near the curb, think about Cars can leak gasoline. Gasoline looked at your water heater? Unless how much damage could be caused vapors are heavier than air, so they it’s in the garage, it is supposed to by a runaway leak when it takes would gather at floor level. Most have a drip pan under it, with at hours for the water department to garages are open enough to allow least a 1 inch diameter drain line, respond to your call. some of the vapor to escape [from a directed to a visible location In the case of water heaters, and small leak], hence the 18 inch [preferably outside]. That way, plumbing in general, “out of sight is height. Does this apply to electric when [not if] it leaks, you may have out of mind” may not be in your heaters too? You bet. Switches a visible warning before the flood. Is best interest. generate sparks, and the electric your drip pan bigger than the By the way, new homes always thermostat operates a switch. diameter of the heater to catch all need an inspection too. Be sure of Gas water heaters offer additional probable leaks? It is clear of what you are buying, and avoid ugly dangers. The hot combustion gasses insulation and other debris that surprises with a thorough home are supposed to be directed outside could plug the drain? Most are not. inspection, before you close the by the flue pipe. Right on the side of If your water heater is in your deal. You will save money and each section of the pipe it says keep garage and you have a bunch of trouble in the long run. at least one inch space from stuff stored in your garage, you flammable materials. Does wood might appreciate having a drip pan Stephen Ruback is a licensed burn? Does plastic burn? Of course, under that water heater too. Professional Inspector; member of so make sure nothing is too close to Where is your shut off valve? TAREI [Texas Association of Real your flue pipe – like rafters, roofing When the water heater leaks, it Estate Inspectors] and HAR materials, foam insulated pipes or would be handy to be able to shut [Houston Association of Realtors]; plastic ducts. off the hot water line and still be approved by TREC [Texas Real If your flue pipe doesn’t specify a able to use the cold facilities. Be Estate Commission] as a clearance distance, it is probably sure you can get to that valve. Not Professional Home Inspection single wall type that gets even hotter all are accessible. Even worse, some Instructor. and requires even more space. Such have been installed on the output In addition, he has earned a BS in flue pipes are outmoded and side which turns off the hot water engineering from Trinity University, considered unsafe. Schedule flow to the house, but does not stop is an author of several books and replacement as soon as possible. the water coming into the water teaches a variety of self Gas water heaters actually have a heater – oops. empowerment courses through fire in the bottom to heat the water. Corroded fittings, valves and Leisure Learning. For more This fire requires lots of air to joints indicate a problem waiting to information, he can be reached at support the combustion. Inadequate happen. It’s usually more 832-489-1071. combustion air causes generation of convenient to have these taken care carbon monoxide. of before they spring into While any exhaust fumes are not emergency mode. Most plumbing