Accurate Online Silica Analyzers, Silica Analyzer, High Sensitivity Online Silica Monitor, Sodium & Silica Trace Measurement System For More Information Please Logon http://cutt.us/OrU4p
2. R
ONLINE STEAM SODIUM
ANALYZER
The Online Steam Sodium Analyzer have been modernized record online steam sodium meters. They have been
most appropriate matched for modernized industrial applications, preferred for energy plants as well as alternative
associated application, granted with Professional ppb turn sodium electrode that is specifically written for cation
sodium measurement. Beside being rarely correct the online sodium meters have been really low maintenance.
The singular underline of the meters have been tall grade of fortitude as well as Large LCD, display. These units
have been row mounted for easy operation.
Features
Ÿ Professional ppb turn sodium electrode.
Ÿ Special designmen for cation sodium measurement.
Ÿ The lowest upkeep of a analyzer.
Ÿ Large LCD display.
Ÿ The fortitude is high.
Ÿ Low upkeep consumption.
Ÿ The row ascent is easy for operating.
Technical Specifications
Transmitter Data
Measuring Range:
0.00~9.36) pNa,0.01μg/L~23.0g/L,(-1000~+1000)mV
Min. Resolution:
0.01pNa,0.01ug/L,0.1mV
Accuracy:
0.01pNa, 1display byte, ± 0.5mV(between ±10℃of the calibration
temperature)
Stability:
±0.01pNa/24h,±1display byte/24h,±0.5mV/24h
Current Output:
(0~10)mA or (0~20)mA or (4~20)mA(two channel isolated output)
Output Precision:
±1%F.
Max. Output loading:
800Ω
Power Supply:
(220±22)VAC, (50±1)Hz
TECHNOLOGIES PVT. LTD.
3. R
Power Consumption:
8W
Insulation:
Line & Neutral of power supply to earth, 1500V/1minute, no flying arc
Alarm Output
high concentration alarm、low concentration alarm、high temperature alarm、
low temperature alarm(the alarm value can be changed by program, two items
in four can be set.)
Conmmunication:
CAN bus(optional)
Auto Data Record
It can record the history data, history event and calibration record automatically
Instrument Data
Measuring Range:
(1.00~8.00)pNa, 0.23ug/L~2300mg/L
Min. Resolution:
0.01pna or 0.01ug/l
Accuracy:
±0.02pna or ±0.5ug/l, the larger one (during the ±10℃of the calibration
temperature)
Responding Time:
reach 90% in 2 minutes at 25℃
Temperature Electrode:
Pt1000
Temperature Range:
Temperature Precision:
Temperature Resolution:
Temperature Compensation Range: (0.1~60.0)℃(automatic or manual)
Calibration:
sample and two points standard solution calibration.
Overall Dimension:
450W×690H×190Dmm(panel mounting)
Panel Cutout:
410mm×645mm
Weight:
20kg
Sample Data
Temperature:
(5~50)℃
Pressure:
( 50~300)Kpa
Flow:
(6~40)L/H
Solid allows in sample: ≤5 um
(no jelly and grease in the
sample)
Environment Data
Ambient Temperature:
(5~45)℃
Ambient Humidity:
≤90%RH (no condensation)
Transportation Temp.:
(-25~55)℃(the transportation temperature of the electrode should be higher
than 0℃
TECHNOLOGIES PVT. LTD.
4. An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485
WHO: GMP Products | GLP Compliant Products
www.acmasindia.com |
www.acmasglobal.com | www.measuring-meters.com
TECHNOLOGIES PVT. LTD.
CORPORATE OFFICE/ SHOWROOM (INDIA)
Plot No. 352-353, Sector – 57
Phase- IV Kundli, Sonepat, Haryana - 131028
Land Line No.: +91 - 11- 47619688,
Fax: +91-11-47619788
E-mail.: info@acmasindia.com
SALES OFFICE (HONG KONG)
Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East,
Sheung Wan, Hong Kong (PRC)
Tel.: 0086-13929598046 | 0086- 18922303099
E-mail.: hk@acmasindia.com
SALES OFFICE (RUSSIA)
Inmed Trade Street Ozerkovsky Embankment,
Unit No 50, Straine- 1, Off- 502, Moscow, Russia
E-mail.: info@acmasindia.com
Tel.: 0049- 79592345 | Email: russia@acmasindia.com