Column Sensor | Cantilever Beam Load Cell | S-type Tension Pressure Sensor | Capsule Sensor | Tension Sensor | Multi Dimensional Force Sensor | Micro Sensor | Spoke Pressure Sensor | Weighing Module | Static Torque Sensor | Dynamic Torque Sensor | Diffused Silicon Pressure Transmitter | Weighing Junction Box | Weighing Transducer

1 of 2
Download to read offline
DAYSENSOR
DYX-309 Coverlever-type weighing sensor
Features:
·Special for concrete folding machine
·The structure is highly low
·The comprehensive accuracy is high
·Anti-interference signals are stable
·Quality alloy steel with nickel plating
·widely used in electronic belt scale,
packaging scale, filling scale In the
equal weighing equipment.And the
automation equipment field and testing
Trial field.
qualification
Rated quantitative schedule Kg 50-1000
Output sensitivity mV/V 2.0±0.05
Zero point output %F.S. ±1
Non-linear %F.S. 0.03
lag %F.S. 0.03
Repeatability %F.S. 0.03
Creep (30 min) %F.S. 0.03
Temperature sensitivity drift %F.S./10℃ 0.03
Zero temperature drift %F.S./10℃ 0.05
Response frequency Hz 1k
Material 42CrMoA
impedance Ω 350
Insulation resistance MΩ/100V DC ≥5000
Use voltage V 5-15
Operating temperature range ℃ -20-60
Safety overload %R.C. 150
Extreme overload %R.C. 200
Cable line specifications m Φ5*3m
Cable limit pull force N 98
TEDS selectable
1) High temperature sensors are available, with a maximum operating temperature of 150℃.
2) High impedance sensors can be provided with an output impedance of 1000 Ω.
https://www.loadcells.store
DAYSENSOR
Product Size Fig
Unit: mm
Range (kg) 50 100 200 500 1000
force diagram
The groove is the force point
Ad

Recommended

More Related Content

Similar to DYX-309.pdf

Similar to DYX-309.pdf (20)

DYLF-102.pdf
DYLF-102.pdfDYLF-102.pdf
DYLF-102.pdf
 
DYPB-002.pdf
DYPB-002.pdfDYPB-002.pdf
DYPB-002.pdf
 
DYLF-105.pdf
DYLF-105.pdfDYLF-105.pdf
DYLF-105.pdf
 
DYPB-001.pdf
DYPB-001.pdfDYPB-001.pdf
DYPB-001.pdf
 
DYBH-101.pdf
DYBH-101.pdfDYBH-101.pdf
DYBH-101.pdf
 
DYPB-003.pdf
DYPB-003.pdfDYPB-003.pdf
DYPB-003.pdf
 
DYQ-101.pdf
DYQ-101.pdfDYQ-101.pdf
DYQ-101.pdf
 
DYZX-001.pdf
DYZX-001.pdfDYZX-001.pdf
DYZX-001.pdf
 
DYLY-106.pdf
DYLY-106.pdfDYLY-106.pdf
DYLY-106.pdf
 
DYTSC.pdf
DYTSC.pdfDYTSC.pdf
DYTSC.pdf
 
DYX-305.pdf
DYX-305.pdfDYX-305.pdf
DYX-305.pdf
 
DYLY-107.pdf
DYLY-107.pdfDYLY-107.pdf
DYLY-107.pdf
 
DYLY-109.pdf
DYLY-109.pdfDYLY-109.pdf
DYLY-109.pdf
 
DYMH-101.pdf
DYMH-101.pdfDYMH-101.pdf
DYMH-101.pdf
 
DYLY-103.pdf
DYLY-103.pdfDYLY-103.pdf
DYLY-103.pdf
 
DYLY-105.pdf
DYLY-105.pdfDYLY-105.pdf
DYLY-105.pdf
 
DYLY-101.pdf
DYLY-101.pdfDYLY-101.pdf
DYLY-101.pdf
 
DYMK-007.pdf
DYMK-007.pdfDYMK-007.pdf
DYMK-007.pdf
 
DYMH-103.pdf
DYMH-103.pdfDYMH-103.pdf
DYMH-103.pdf
 
DYLY-108.pdf
DYLY-108.pdfDYLY-108.pdf
DYLY-108.pdf
 

More from arco zhang

More from arco zhang (20)

DYZ-103.pdf
DYZ-103.pdfDYZ-103.pdf
DYZ-103.pdf
 
DYZL-101.pdf
DYZL-101.pdfDYZL-101.pdf
DYZL-101.pdf
 
DYZ-109.pdf
DYZ-109.pdfDYZ-109.pdf
DYZ-109.pdf
 
DYZ-106.pdf
DYZ-106.pdfDYZ-106.pdf
DYZ-106.pdf
 
DYZC-055.pdf
DYZC-055.pdfDYZC-055.pdf
DYZC-055.pdf
 
DYZ-014.pdf
DYZ-014.pdfDYZ-014.pdf
DYZ-014.pdf
 
DYZ-107.pdf
DYZ-107.pdfDYZ-107.pdf
DYZ-107.pdf
 
DYZ-102.pdf
DYZ-102.pdfDYZ-102.pdf
DYZ-102.pdf
 
DYZ-100.pdf
DYZ-100.pdfDYZ-100.pdf
DYZ-100.pdf
 
DYZL-106.pdf
DYZL-106.pdfDYZL-106.pdf
DYZL-106.pdf
 
DYZL-104.pdf
DYZL-104.pdfDYZL-104.pdf
DYZL-104.pdf
 
DYZ-013.pdf
DYZ-013.pdfDYZ-013.pdf
DYZ-013.pdf
 
DYZ-104.pdf
DYZ-104.pdfDYZ-104.pdf
DYZ-104.pdf
 
DYTB-001.pdf
DYTB-001.pdfDYTB-001.pdf
DYTB-001.pdf
 
DYZ-015.pdf
DYZ-015.pdfDYZ-015.pdf
DYZ-015.pdf
 
DYZ-011.pdf
DYZ-011.pdfDYZ-011.pdf
DYZ-011.pdf
 
DYZHL.pdf
DYZHL.pdfDYZHL.pdf
DYZHL.pdf
 
DYZ-105.pdf
DYZ-105.pdfDYZ-105.pdf
DYZ-105.pdf
 
DYZ-101.pdf
DYZ-101.pdfDYZ-101.pdf
DYZ-101.pdf
 
DYZL-105.pdf
DYZL-105.pdfDYZL-105.pdf
DYZL-105.pdf
 

DYX-309.pdf

  • 1. DAYSENSOR DYX-309 Coverlever-type weighing sensor Features: ·Special for concrete folding machine ·The structure is highly low ·The comprehensive accuracy is high ·Anti-interference signals are stable ·Quality alloy steel with nickel plating ·widely used in electronic belt scale, packaging scale, filling scale In the equal weighing equipment.And the automation equipment field and testing Trial field. qualification Rated quantitative schedule Kg 50-1000 Output sensitivity mV/V 2.0±0.05 Zero point output %F.S. ±1 Non-linear %F.S. 0.03 lag %F.S. 0.03 Repeatability %F.S. 0.03 Creep (30 min) %F.S. 0.03 Temperature sensitivity drift %F.S./10℃ 0.03 Zero temperature drift %F.S./10℃ 0.05 Response frequency Hz 1k Material 42CrMoA impedance Ω 350 Insulation resistance MΩ/100V DC ≥5000 Use voltage V 5-15 Operating temperature range ℃ -20-60 Safety overload %R.C. 150 Extreme overload %R.C. 200 Cable line specifications m Φ5*3m Cable limit pull force N 98 TEDS selectable 1) High temperature sensors are available, with a maximum operating temperature of 150℃. 2) High impedance sensors can be provided with an output impedance of 1000 Ω. https://www.loadcells.store
  • 2. DAYSENSOR Product Size Fig Unit: mm Range (kg) 50 100 200 500 1000 force diagram The groove is the force point