1. 1
REPORT PRESENTATION ON
STUDENT INDUSTRIAL WORK EXPERIENCE SCHEME (SIWES)
AT
MBS ENGINEERING LIMLTED, ABUJA.
(BUILDING SERVICES AND CONSULTANCY COMPANY)
BY
AHMED USMAN
U09EE1048
DEPARTMENT OF ELECTRICAL & COMPUTER ENGINEERING
AHMADU BELLO UNIVERSITY, ZARIA.
APRIL, 2014
2. 2
INTRODUCTION
SIWES is a program designed by the university to
expose students to the practical aspects of their course
of study.
MBS Engineering Limited provides sustainable
mechanical and electrical services for buildings,
institutional and industrial complexes.
AHMED USMAN U09EE1048
3. 3
AIM AND OBJECTIVES
To acquire practical experience and professional
skills in the course of study.
AHMED USMAN U09EE1048
Skills that will serve as an aid to prospective
employment after graduation.
4. 4
OUTLINE OF THE TRAINING
ELECTRICAL SERVICES DESIGN
Lighting design
Power design
Distribution board design
Schematics design
Cable sizing
External lighting design
AHMED USMAN U09EE1048
5. LIGHTING LOAD DESIGN
This is the installation of sufficient number of
lamps and switches for a building.
The number of lamp is calculated using lumen
method.
AHMED USMAN U09EE1048
5
No. of lamps =
Area X Lux
Lamp lumen X Maintenance factor
7. POWER LOAD DESIGN
This is the installation of sufficient number of
accessories and load points.
This accessories includes Sockets, CCU, air conditions,
water heaters, television outlets etc.
AHMED USMAN U09EE1048
7
9. 9
DISTRIBUTION BOARD DESIGN
This is the design of a board that will distribute power
to each point in a building.
AHMED USMAN U09EE1048
𝑃𝑑 = √3𝐼𝑉𝑐𝑜𝑠∅
The design is based on calculation of total power
and current.
10. A) 1Φ, SIX WAYS. B) 3Φ, FOUR WAYS.
10
AHMED USMAN U09EE1048
DISTRIBUTION BOARD cont’
Figure 3: Distribution Board Schematics Design
11. 11
SCHEMATIC DESIGN
This is the design of system layout
AHMED USMAN U09EE1048
Figure 4: Schematic Design For Lighting And Power DB’s
12. 12
CABLE SIZING
The following points are considered in sizing a cable
Diversity factor
Current carrying capacity
Permissible voltage drop
Allowable (DV) < 2.5% of total voltage
AHMED USMAN U09EE1048
13. 13
ELECTRICAL GRAPHICAL SYMBOLS DESIGN
This is the design of symbols that represent the
electrical accessories.
AHMED USMAN U09EE1048
Figure 5: electrical symbol representation
14. 14
EXPERIENCE ACCOMPLISHED
Use of AutoCAD (drafting tool).
An Insight into electrical services design.
Preparation of bill of quantity.
Wiring and installation of electrical accessories.
Detection of electrical fault in a building.
AHMED USMAN U09EE1048
15. 15
CONCLUSION
As a student of Electrical Engineering, I have been
able to achieve the relevant and effective practical
industrial training and experiences within period at
MBS Engineering LTD.
AHMED USMAN U09EE1048