SlideShare a Scribd company logo
Resolite Sheds New Light
           TRED-SAFE™ SPECIFICATIONS
                                                                                                                                      on Walkable FRP Roof Panels
           1. Walkable fiberglass reinforced polymer wall/roof panels shall be Resolite
              Tred-Safe Type 1645 translucent or opaque, corrosion resistant and fire retardant
              as manufactured by Resolite, Moscow, TN., www.resolite.com,


                                                                                                                       Truly Walkable FRP Roof
              1-888-RESOLITE (1-888-737-6548).
           2. Panel manufacturer shall be ISO 9002 certified.
           3. Resin shall be high quality isophthalic, neopentyl glycol and halogenated polyester
              with acrylic modification and UV stabilizers. Resin content of the panel shall be a
              minimum of 55% by weight.                                                                                  Panel
           4. Glass reinforcement shall be composed of multiple layers of bidirectional
              continuous strand WOVEN MAT and chopped strand multi-directional glass. Glass


                                                                                                                       High Resin Content for
              content shall be a maximum 45% by weight. Both the interior and exterior surface of
              the panel shall have an internal Corrosion Weathering (C/W) barrier fused to the
              fiberglass matrix during the manufacturing process.
           5. Panel finish shall have an embossed exterior and embossed interior to
              maximize panel longevity.
                                                                                                                        Improved Corrosion
           6. Panel weight shall be nominal 16 ounces per square foot.
           7. Color shall be translucent #35 Frost with a 50% light transmission OR opaque #33                           Resistance
              Stone White. (Special Custom Colors are available by request)
           8. Profile shall be standard: 7.2 x 1.5” or 4.2 x 1-1/16 optional: 7.2D x 1.75.


                                                                                                                       WOVEN Fiberglass Mat
           9. Panels shall be Class 1 Fire Rated with a Flame Spread of 25.
              The flame spread rating shall be achieved without the use of fillers.

                                                                                                                         Reinforcement for Added
           STATEMENT OF POLICY
           The information provided herein is solely based on factual data available to Resolite from many               Safety in Roof Applications
           years of experience in manufacturing, field evaluation, testing and research. This is to be used



                                                                                                                       Class 1 Fire Rated
           only as a general guide by the designer and builder.

           The overall satisfactory performance of any structural application is predicated by proper design
           and erection. Resolite will not assume any responsibility for the design, detailing, or erection of the
           substructure to which Resolite panels are attached.

           STORAGE RECOMMENDATIONS
                                                                                                                         Flame Spread 25
           Prior to installation, Resolite panels should be stored indoors in an upright position. Never pile flat,



                                                                                                                       Opaque  Translucent Panels
           as condensation may form between the panels causing internal fiberbloom and permanent dam-
           age.

           COLOR NOTICE
           Resolite disclaims all warranties expressed or implied with respect to color and/or translucency of
           polyester resin products.

           ADDITIONAL RESOLITE CATALOGS
           Literature and samples availible upon request.

           DISCLAIMER
           The information contained herein is for information purposes only. Resolite reserves the right to
           change or withdraw such information, or the designs and details of the products upon which it is
           based, either wholly or in any portion thereof, without further notice. For design and detailing
           assistance on specific products, contact your Resolite sales representative.
                                                                                                                                 ®




                                                                                                                                                   TM


                                     285 Industrial Drive
                                     Moscow, TN 38057
                  ®
                                     Ph: 888-RESOLITE (888-737-6548)
www.resolite.com                     Fax: 901-877-1388
                                     Email: sales@resolite.com
TM




      Tred-Safe Features

• A Truly Walkable † Roof Panel- has high impact                                       • Two Standard Colors- opaque 33 Stone White
  resistance and is capable of safely supporting                                         and translucent 35 Frost (50% light
                                                                                                                                                        Roofing Live Load (PSF)
  normal foot traffic and weight of a maintenance                                        transmission). Custom colors also available.                                     20                   30                           40                         50                                         60
  worker without buckling or damage.
                                                                                       • Two standard Profiles- 7.2 x 1.5 and 4.2 x                              1       2      3       1      2       3          1        2     3            1        2           3             1               2         3
• Fire Rated - Class 1 Flame Spread classification of 25*.                               1-1/16. Optional profiles: 7.2D x 1.75                         7.2     7’9” 10’5” 9’7” 6’10” 9’1” 8’5”              6’2” 8’1” 7’8”                 5’9”      7’2”        7’1” 5’5” 6’7”                         6’8”

• Corrosion Resistant- produced with high resin                                        • Outstanding Performance- Tred-Safe is                            4.2     5’7” 7’6” 6’10” 4’10” 6’6” 6’0”              4’5” 5’9” 5’5”                 4’1”      5’2”        5’1” 3’10” 4’9”                        4’9”
  content (55% by weight) premium quality isophthalic                                    backed by 30 years of case history in the
  halogenated polyester resin.                                                           corrosion and industrial market.                               Siding / Roofing Wind Load (PSF)
• Outstanding Weathering- our premium quality resin                                    • Load/Span Data- based on full scale tests to                                     20                    30                          40                          50                                        60
  incorporates neopentyl glycol, acrylic modification                                    simulate actual field conditions.                                                                                                                                                         1              2         3
                                                                                                                                                                   1      2      3       1       2       3          1       2      3           1         2           3
  and UV stabilizers.
                                                                                       • Exceeds ASTM D 3841- standard                                    7.2    10’2” 13’2” 12’7” 8’11” 10’9” 11’0” 8’1” 9’3” 10’0”                          7’6” 8’4”             9’3”         7’1” 7’5”                 8’6”
• Embossed Surface- both exterior and interior                                           specification for Glass- Fiber- Reinforced
  surface finishes are embossed creating a resin rich                                    Polyester Plastic Panels.                                        4.2     7’4” 9’5”     9’0”     6’4” 7’8” 7’10” 5’9” 6’8”               7’2”         5’4” 6’0”             6’8”         5’1” 5’5”                 6’1”
  surface to improve UV and corrosion resistance.
                                                                                                                                                                                                                                            Notes:
• C/W Barrier Protection- a protective barrier on both                                                                                             TM


                                                                                                                                                        Types Available                                      1645                           1. Load/Span limits are based on full scale panel tests
                                                                                                                                                                                                                                               representing actual field conditions.
                                                                                                                                    TM




  exterior and interior surfaces that is fused into the                                                                                                                                                                                     2. Panel span/deflection ratios (L/D) shall be limited to
                                                                                                                                                        Nominal Weight, oz./sq. ft.                         16 oz.
  resin/fiberglass matrix to give the panel even greater                                                                                                                                                                                       L/20 for wind loads and L/45 for live loads.
                                                                                                                                                                                                                                            3. Factors of safety shall be 1.88 for panels subject to
                                                                                                                          TM




  protection against degradation and eliminate any need                                                                        TM



                                                                                                                                                        Nominal Thickness, in.**                             .100                              wind loads and 2.5 for panels subjected to live loads.
  for surface applied coatings.                                                                                                                                                                                                             4. Load/Span limits are based on fasteners with 3/4
                                                                                                                                                        Nominal Resin Content                                55%                               washers in every low for 7.2 and fasteners with 5/8”
                                                                                               TM             TM




                                                                                                                                                                                                                                               washers in every other low for 4.2.
• Multiple Glass Reinforcements- Tred-Safe panels                                                                                                       Hardness, Barcol                                                                    5. Other panel types, weights, glass reinforcements, resin
  utilize a 5 layer combination of glass reinforcement                                                                                                                                                        40                               types, lengths, fastening options, or special loading
                                                                                                                                                        ASTM D 2583                                                                            requirements may be available. Please contact Resolite
  including bidirectional continuous strand WOVEN and                                                                                                                                                                                          Customer Service Department for more information.
  chopped strand glass. This multi-layered glass fiber                                                                                                  Flexural Stength, psi
                                                                                       Tred-Safe™ FRP Composite Panel                                   ASTM D 790
                                                                                                                                                                                                          42,000
  reinforcement provides:
  • Better impact resistance                                                                                                                            Flexural Modulus, psi                                                                7.2 x 1.5” Rib (optionalcoverage 43.2)
                                                                                                                                                                                                                                                            optional
                                                                                                                                                                                                                                                                      width 46.5
                                                                                               Embossed Resin Rich Surface                                                                                              6
  • Better fastener pullover values                                                                                                                     ASTM D 790                                      1.30 x 10
  • Better resistance to longitudinal splitting
  • Better resistance to internal shear stresses                                                                                                        Tensile Strength, psi                                                                                7.2
                                                                                       Chopped Strand Fiberglass
                                                                                                                                                        ASTM D 638                                        32,000                                                                                  1-1/2
                                                                                                                                                                                                                                                                        36 Coverage
  • Uniform longitudinal and transverse reinforcements
                                                                                                                                                                                                                                                                    39.25 Finish Width
   provide increased flexural stability under cyclic                                                                                                    Fire Resistance Ignition Point               820° F to 900° F
    loading                                                                                                                                             ASTM D 1929
                                                                                                                                                                                                                                            4.2 x 1-1/16” Corrugated
                                                                                                                                                        Flame Spread Classification
 †
   A Tred-Safe walkable panel is one that is resistant to puncturing and tearing; is                                                                    ASTM E 84                                            25*
 rugged and durable; and is capable of safely supporting normal foot traffic and the                                                                                                                                                                         4.2                       1-1/16
 weight of a maintenance worker without buckling or damage. Please note that                                                                                                                                                                                         37.8 Coverage
 beyond actual material capabilities, standard construction safety measures must be                                                                     Flammability                       Average Time of Burning less than 5 sec
                                                                                                       Bidirectional Woven                                                                Average Extent of Burning less than 15 mm                                  42 Finish Width
 observed and are the responsibility of the owner. Under actual service conditions
 such as elevated temperatures or corrosive environments, some reduction in strength                Fiberglass Reinforements                            ASTM D 635                         Building Code Classification CC1 or C1
 is possible over time, thus limiting the walkability of the panels. This should be                                                                                                                                                     *  Resolite advises that the numerical flame spread
 considered when selecting the allowable spans and when accessing the roof for                                                                                                                                                             classification is not intended to reflect hazards presented
 maintenance. Maximum walkable spans should be limited to 7' 6. Simple spans are                       C/W Barrier                           TM

                                                                                                                                                        Coefficient of Expansion                        2.89 x 10-5                        by this or any other material under actual fire conditions.
 not recommended for foot traffic; planks or ladders should be used for these                                                                           (in/in °F) ASTM D696                                                            ** All thicknesses based on flat material. Nominal
 conditions.                                                                                                                                                                                                                               thickness varies with profile.

More Related Content

What's hot

CMS Danskin Product Guide
CMS Danskin Product GuideCMS Danskin Product Guide
CMS Danskin Product GuideAshlie Carty
 
I2i Presentation
I2i PresentationI2i Presentation
I2i Presentation
nawlij
 
FIXXUS contributes to food safety compliance
FIXXUS contributes to food safety complianceFIXXUS contributes to food safety compliance
FIXXUS contributes to food safety compliance
Danny Cook
 
RnM Brochure
RnM BrochureRnM Brochure
RnM Brochure
Aaquib Ansari
 
Expansion Brochure
Expansion BrochureExpansion Brochure
Expansion Brochure
José Luis Jarpa
 
Re-grout clark bros 4 cyl hyper compressor
Re-grout clark bros 4 cyl hyper compressorRe-grout clark bros 4 cyl hyper compressor
Re-grout clark bros 4 cyl hyper compressor
Gert-Jan Mulder
 
Debabrata Panda_118CR0681_Tribology assignment.pptx
Debabrata Panda_118CR0681_Tribology assignment.pptxDebabrata Panda_118CR0681_Tribology assignment.pptx
Debabrata Panda_118CR0681_Tribology assignment.pptx
DEBABRATAPANDA20
 
Sort overview of what we do
Sort overview of what we doSort overview of what we do
Sort overview of what we do
Joe Tillman
 
Sustainability in Ceilings
Sustainability in CeilingsSustainability in Ceilings
Sustainability in CeilingsOverbury
 
Ruredil PBO Data Sheet
Ruredil PBO Data SheetRuredil PBO Data Sheet
Ruredil PBO Data Sheet
Patrick J. Morrissey
 
Producing Flaked Breakfast Cereals
Producing Flaked Breakfast CerealsProducing Flaked Breakfast Cereals
Producing Flaked Breakfast Cereals
Milling and Grain magazine
 
composites
compositescomposites
composites
musinirambabu
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
IJERD Editor
 
Boen fitness english_final_mpe0t
Boen fitness english_final_mpe0tBoen fitness english_final_mpe0t
Boen fitness english_final_mpe0t
Kavaler
 
No. 3 & 5 gough hill path rbl 1169 the peak
No. 3 & 5 gough hill path rbl 1169 the peakNo. 3 & 5 gough hill path rbl 1169 the peak
No. 3 & 5 gough hill path rbl 1169 the peakbumatech
 

What's hot (20)

CMS Danskin Product Guide
CMS Danskin Product GuideCMS Danskin Product Guide
CMS Danskin Product Guide
 
I2i Presentation
I2i PresentationI2i Presentation
I2i Presentation
 
FIXXUS contributes to food safety compliance
FIXXUS contributes to food safety complianceFIXXUS contributes to food safety compliance
FIXXUS contributes to food safety compliance
 
RnM Brochure
RnM BrochureRnM Brochure
RnM Brochure
 
Dodge USAF Bearings Brochure
Dodge USAF Bearings BrochureDodge USAF Bearings Brochure
Dodge USAF Bearings Brochure
 
SMARTDEK-Brochure
SMARTDEK-BrochureSMARTDEK-Brochure
SMARTDEK-Brochure
 
321 r
321 r321 r
321 r
 
Expansion Brochure
Expansion BrochureExpansion Brochure
Expansion Brochure
 
Re-grout clark bros 4 cyl hyper compressor
Re-grout clark bros 4 cyl hyper compressorRe-grout clark bros 4 cyl hyper compressor
Re-grout clark bros 4 cyl hyper compressor
 
Debabrata Panda_118CR0681_Tribology assignment.pptx
Debabrata Panda_118CR0681_Tribology assignment.pptxDebabrata Panda_118CR0681_Tribology assignment.pptx
Debabrata Panda_118CR0681_Tribology assignment.pptx
 
Sort overview of what we do
Sort overview of what we doSort overview of what we do
Sort overview of what we do
 
Sustainability in Ceilings
Sustainability in CeilingsSustainability in Ceilings
Sustainability in Ceilings
 
Boot Brochure
Boot BrochureBoot Brochure
Boot Brochure
 
Structure
StructureStructure
Structure
 
Ruredil PBO Data Sheet
Ruredil PBO Data SheetRuredil PBO Data Sheet
Ruredil PBO Data Sheet
 
Producing Flaked Breakfast Cereals
Producing Flaked Breakfast CerealsProducing Flaked Breakfast Cereals
Producing Flaked Breakfast Cereals
 
composites
compositescomposites
composites
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
 
Boen fitness english_final_mpe0t
Boen fitness english_final_mpe0tBoen fitness english_final_mpe0t
Boen fitness english_final_mpe0t
 
No. 3 & 5 gough hill path rbl 1169 the peak
No. 3 & 5 gough hill path rbl 1169 the peakNo. 3 & 5 gough hill path rbl 1169 the peak
No. 3 & 5 gough hill path rbl 1169 the peak
 

Similar to Tred Safe Product Brochure

Glass Ceramic Prod Lit09lr
Glass Ceramic Prod Lit09lrGlass Ceramic Prod Lit09lr
Glass Ceramic Prod Lit09lr
andrewsavile
 
Why sgp laminated glass cannot be replaced by dg41 laminated glass
Why sgp laminated glass cannot be replaced by dg41 laminated glassWhy sgp laminated glass cannot be replaced by dg41 laminated glass
Why sgp laminated glass cannot be replaced by dg41 laminated glass
QINGDAO MORN BUILDING MATERIALS CO.,LTD
 
Ant-tracking Silicone Compound from Project Sales Corp, India
Ant-tracking Silicone Compound from Project Sales Corp, IndiaAnt-tracking Silicone Compound from Project Sales Corp, India
Ant-tracking Silicone Compound from Project Sales Corp, IndiaProject Sales Corp
 
Executive Brcohure 2009
Executive Brcohure 2009Executive Brcohure 2009
Executive Brcohure 2009
jimweaver
 
Reznoclad Brochure final_2016
Reznoclad Brochure final_2016Reznoclad Brochure final_2016
Reznoclad Brochure final_2016Reznoclad HPL
 
Tech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_EmailTech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_EmailMiddle East Insulation LLC
 
Newsletter electrical july 2004
Newsletter electrical july 2004Newsletter electrical july 2004
Newsletter electrical july 2004Project Sales Corp
 
Alpha exactalloy Solder preforms for product and process improvement
Alpha exactalloy Solder preforms for product and process improvementAlpha exactalloy Solder preforms for product and process improvement
Alpha exactalloy Solder preforms for product and process improvement
reginahuse
 
Abrasion Resistant Coatings on Polycarbonate
Abrasion Resistant Coatings on PolycarbonateAbrasion Resistant Coatings on Polycarbonate
Abrasion Resistant Coatings on Polycarbonate
dmulvilleacree
 
Renolit stretch ceiling films.
Renolit stretch ceiling films.Renolit stretch ceiling films.
Renolit stretch ceiling films.
Vivek Todi
 
Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...
Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...
Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...
Sartomer
 
Liquid Asphaltic Composition (LAC) - RIW
Liquid Asphaltic Composition (LAC) - RIW Liquid Asphaltic Composition (LAC) - RIW
Liquid Asphaltic Composition (LAC) - RIW
RIW Ltd
 
RIW Flexiseal
RIW Flexiseal RIW Flexiseal
RIW Flexiseal
RIW Ltd
 
Failure analysis & test procedure #1 rev
Failure analysis & test procedure #1 revFailure analysis & test procedure #1 rev
Failure analysis & test procedure #1 rev
Bambang Afrinaldi
 
Noble Drilling Case Study - Thread Pastes - Project Sales Corp
Noble Drilling Case Study - Thread Pastes - Project Sales CorpNoble Drilling Case Study - Thread Pastes - Project Sales Corp
Noble Drilling Case Study - Thread Pastes - Project Sales CorpProject Sales Corp
 
New uv curing oled encapsulation adhesive with low water
New uv curing oled encapsulation adhesive with low waterNew uv curing oled encapsulation adhesive with low water
New uv curing oled encapsulation adhesive with low watertimknight8
 

Similar to Tred Safe Product Brochure (20)

Glass Ceramic Prod Lit09lr
Glass Ceramic Prod Lit09lrGlass Ceramic Prod Lit09lr
Glass Ceramic Prod Lit09lr
 
732
732732
732
 
Why sgp laminated glass cannot be replaced by dg41 laminated glass
Why sgp laminated glass cannot be replaced by dg41 laminated glassWhy sgp laminated glass cannot be replaced by dg41 laminated glass
Why sgp laminated glass cannot be replaced by dg41 laminated glass
 
Ant-tracking Silicone Compound from Project Sales Corp, India
Ant-tracking Silicone Compound from Project Sales Corp, IndiaAnt-tracking Silicone Compound from Project Sales Corp, India
Ant-tracking Silicone Compound from Project Sales Corp, India
 
Executive Brcohure 2009
Executive Brcohure 2009Executive Brcohure 2009
Executive Brcohure 2009
 
Reznoclad Brochure final_2016
Reznoclad Brochure final_2016Reznoclad Brochure final_2016
Reznoclad Brochure final_2016
 
Tech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_EmailTech_Brochure_Cladding_Remake_Booklet_LQ_Email
Tech_Brochure_Cladding_Remake_Booklet_LQ_Email
 
Newsletter electrical july 2004
Newsletter electrical july 2004Newsletter electrical july 2004
Newsletter electrical july 2004
 
Metal protector
Metal protectorMetal protector
Metal protector
 
Alpha exactalloy Solder preforms for product and process improvement
Alpha exactalloy Solder preforms for product and process improvementAlpha exactalloy Solder preforms for product and process improvement
Alpha exactalloy Solder preforms for product and process improvement
 
Abrasion Resistant Coatings on Polycarbonate
Abrasion Resistant Coatings on PolycarbonateAbrasion Resistant Coatings on Polycarbonate
Abrasion Resistant Coatings on Polycarbonate
 
filmquest 4 pages
filmquest 4 pagesfilmquest 4 pages
filmquest 4 pages
 
Renolit stretch ceiling films.
Renolit stretch ceiling films.Renolit stretch ceiling films.
Renolit stretch ceiling films.
 
Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...
Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...
Radiation-Cured Components & Their Use in Hard, Scratch Resistant Coating App...
 
Liquid Asphaltic Composition (LAC) - RIW
Liquid Asphaltic Composition (LAC) - RIW Liquid Asphaltic Composition (LAC) - RIW
Liquid Asphaltic Composition (LAC) - RIW
 
RIW Flexiseal
RIW Flexiseal RIW Flexiseal
RIW Flexiseal
 
Failure analysis & test procedure #1 rev
Failure analysis & test procedure #1 revFailure analysis & test procedure #1 rev
Failure analysis & test procedure #1 rev
 
Noble Drilling Case Study
Noble Drilling Case StudyNoble Drilling Case Study
Noble Drilling Case Study
 
Noble Drilling Case Study - Thread Pastes - Project Sales Corp
Noble Drilling Case Study - Thread Pastes - Project Sales CorpNoble Drilling Case Study - Thread Pastes - Project Sales Corp
Noble Drilling Case Study - Thread Pastes - Project Sales Corp
 
New uv curing oled encapsulation adhesive with low water
New uv curing oled encapsulation adhesive with low waterNew uv curing oled encapsulation adhesive with low water
New uv curing oled encapsulation adhesive with low water
 

Tred Safe Product Brochure

  • 1. Resolite Sheds New Light TRED-SAFE™ SPECIFICATIONS on Walkable FRP Roof Panels 1. Walkable fiberglass reinforced polymer wall/roof panels shall be Resolite Tred-Safe Type 1645 translucent or opaque, corrosion resistant and fire retardant as manufactured by Resolite, Moscow, TN., www.resolite.com, Truly Walkable FRP Roof 1-888-RESOLITE (1-888-737-6548). 2. Panel manufacturer shall be ISO 9002 certified. 3. Resin shall be high quality isophthalic, neopentyl glycol and halogenated polyester with acrylic modification and UV stabilizers. Resin content of the panel shall be a minimum of 55% by weight. Panel 4. Glass reinforcement shall be composed of multiple layers of bidirectional continuous strand WOVEN MAT and chopped strand multi-directional glass. Glass High Resin Content for content shall be a maximum 45% by weight. Both the interior and exterior surface of the panel shall have an internal Corrosion Weathering (C/W) barrier fused to the fiberglass matrix during the manufacturing process. 5. Panel finish shall have an embossed exterior and embossed interior to maximize panel longevity. Improved Corrosion 6. Panel weight shall be nominal 16 ounces per square foot. 7. Color shall be translucent #35 Frost with a 50% light transmission OR opaque #33 Resistance Stone White. (Special Custom Colors are available by request) 8. Profile shall be standard: 7.2 x 1.5” or 4.2 x 1-1/16 optional: 7.2D x 1.75. WOVEN Fiberglass Mat 9. Panels shall be Class 1 Fire Rated with a Flame Spread of 25. The flame spread rating shall be achieved without the use of fillers. Reinforcement for Added STATEMENT OF POLICY The information provided herein is solely based on factual data available to Resolite from many Safety in Roof Applications years of experience in manufacturing, field evaluation, testing and research. This is to be used Class 1 Fire Rated only as a general guide by the designer and builder. The overall satisfactory performance of any structural application is predicated by proper design and erection. Resolite will not assume any responsibility for the design, detailing, or erection of the substructure to which Resolite panels are attached. STORAGE RECOMMENDATIONS Flame Spread 25 Prior to installation, Resolite panels should be stored indoors in an upright position. Never pile flat, Opaque Translucent Panels as condensation may form between the panels causing internal fiberbloom and permanent dam- age. COLOR NOTICE Resolite disclaims all warranties expressed or implied with respect to color and/or translucency of polyester resin products. ADDITIONAL RESOLITE CATALOGS Literature and samples availible upon request. DISCLAIMER The information contained herein is for information purposes only. Resolite reserves the right to change or withdraw such information, or the designs and details of the products upon which it is based, either wholly or in any portion thereof, without further notice. For design and detailing assistance on specific products, contact your Resolite sales representative. ® TM 285 Industrial Drive Moscow, TN 38057 ® Ph: 888-RESOLITE (888-737-6548) www.resolite.com Fax: 901-877-1388 Email: sales@resolite.com
  • 2. TM Tred-Safe Features • A Truly Walkable † Roof Panel- has high impact • Two Standard Colors- opaque 33 Stone White resistance and is capable of safely supporting and translucent 35 Frost (50% light Roofing Live Load (PSF) normal foot traffic and weight of a maintenance transmission). Custom colors also available. 20 30 40 50 60 worker without buckling or damage. • Two standard Profiles- 7.2 x 1.5 and 4.2 x 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 • Fire Rated - Class 1 Flame Spread classification of 25*. 1-1/16. Optional profiles: 7.2D x 1.75 7.2 7’9” 10’5” 9’7” 6’10” 9’1” 8’5” 6’2” 8’1” 7’8” 5’9” 7’2” 7’1” 5’5” 6’7” 6’8” • Corrosion Resistant- produced with high resin • Outstanding Performance- Tred-Safe is 4.2 5’7” 7’6” 6’10” 4’10” 6’6” 6’0” 4’5” 5’9” 5’5” 4’1” 5’2” 5’1” 3’10” 4’9” 4’9” content (55% by weight) premium quality isophthalic backed by 30 years of case history in the halogenated polyester resin. corrosion and industrial market. Siding / Roofing Wind Load (PSF) • Outstanding Weathering- our premium quality resin • Load/Span Data- based on full scale tests to 20 30 40 50 60 incorporates neopentyl glycol, acrylic modification simulate actual field conditions. 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 and UV stabilizers. • Exceeds ASTM D 3841- standard 7.2 10’2” 13’2” 12’7” 8’11” 10’9” 11’0” 8’1” 9’3” 10’0” 7’6” 8’4” 9’3” 7’1” 7’5” 8’6” • Embossed Surface- both exterior and interior specification for Glass- Fiber- Reinforced surface finishes are embossed creating a resin rich Polyester Plastic Panels. 4.2 7’4” 9’5” 9’0” 6’4” 7’8” 7’10” 5’9” 6’8” 7’2” 5’4” 6’0” 6’8” 5’1” 5’5” 6’1” surface to improve UV and corrosion resistance. Notes: • C/W Barrier Protection- a protective barrier on both TM Types Available 1645 1. Load/Span limits are based on full scale panel tests representing actual field conditions. TM exterior and interior surfaces that is fused into the 2. Panel span/deflection ratios (L/D) shall be limited to Nominal Weight, oz./sq. ft. 16 oz. resin/fiberglass matrix to give the panel even greater L/20 for wind loads and L/45 for live loads. 3. Factors of safety shall be 1.88 for panels subject to TM protection against degradation and eliminate any need TM Nominal Thickness, in.** .100 wind loads and 2.5 for panels subjected to live loads. for surface applied coatings. 4. Load/Span limits are based on fasteners with 3/4 Nominal Resin Content 55% washers in every low for 7.2 and fasteners with 5/8” TM TM washers in every other low for 4.2. • Multiple Glass Reinforcements- Tred-Safe panels Hardness, Barcol 5. Other panel types, weights, glass reinforcements, resin utilize a 5 layer combination of glass reinforcement 40 types, lengths, fastening options, or special loading ASTM D 2583 requirements may be available. Please contact Resolite including bidirectional continuous strand WOVEN and Customer Service Department for more information. chopped strand glass. This multi-layered glass fiber Flexural Stength, psi Tred-Safe™ FRP Composite Panel ASTM D 790 42,000 reinforcement provides: • Better impact resistance Flexural Modulus, psi 7.2 x 1.5” Rib (optionalcoverage 43.2) optional width 46.5 Embossed Resin Rich Surface 6 • Better fastener pullover values ASTM D 790 1.30 x 10 • Better resistance to longitudinal splitting • Better resistance to internal shear stresses Tensile Strength, psi 7.2 Chopped Strand Fiberglass ASTM D 638 32,000 1-1/2 36 Coverage • Uniform longitudinal and transverse reinforcements 39.25 Finish Width provide increased flexural stability under cyclic Fire Resistance Ignition Point 820° F to 900° F loading ASTM D 1929 4.2 x 1-1/16” Corrugated Flame Spread Classification † A Tred-Safe walkable panel is one that is resistant to puncturing and tearing; is ASTM E 84 25* rugged and durable; and is capable of safely supporting normal foot traffic and the 4.2 1-1/16 weight of a maintenance worker without buckling or damage. Please note that 37.8 Coverage beyond actual material capabilities, standard construction safety measures must be Flammability Average Time of Burning less than 5 sec Bidirectional Woven Average Extent of Burning less than 15 mm 42 Finish Width observed and are the responsibility of the owner. Under actual service conditions such as elevated temperatures or corrosive environments, some reduction in strength Fiberglass Reinforements ASTM D 635 Building Code Classification CC1 or C1 is possible over time, thus limiting the walkability of the panels. This should be * Resolite advises that the numerical flame spread considered when selecting the allowable spans and when accessing the roof for classification is not intended to reflect hazards presented maintenance. Maximum walkable spans should be limited to 7' 6. Simple spans are C/W Barrier TM Coefficient of Expansion 2.89 x 10-5 by this or any other material under actual fire conditions. not recommended for foot traffic; planks or ladders should be used for these (in/in °F) ASTM D696 ** All thicknesses based on flat material. Nominal conditions. thickness varies with profile.