1. Report Identification: 500 Sea Breeze Dr Page 1 of 39
Inspection Report
John Doe
Property Address:
500 Sea Breeze Dr
Dallas TX 75104
Spec-Pro Inspection Services, LLC
Kevan Brent Giles TREC # 7297
P.O. Box 4328
Cedar Hill, TX 75106
817-247-6819
2. Report Identification: 500 Sea Breeze Dr Page 2 of 39
PROPERTY INSPECTION REPORT
Prepared For: John Doe
(Name of Client)
Concerning: 500 Sea Breeze Dr, Dallas, TX 75104
(Address or Other Identification of Inspected Property)
By: Kevan Brent Giles TREC # 7297 / Spec-Pro Inspection Services, LLC 6/18/2010
(Name and License Number of Inspector) (Date)
(Name, License Number and Signature of Sponsoring Inspector, if required)
This property inspection report may include an inspection agreement (contract), addenda, and other information related to
property conditions. If any item or comment is unclear, you should ask the inspector to clarify the findings. It is important that
you carefully read ALL of this information.
This inspection is subject to the rules (“Rules”) of the Texas Real Estate Commission (“TREC”), which can be found at
www.trec.state.tx.us.
The TREC Standards of Practice (Sections 535.227-535.233 of the Rules) are the minimum standards for inspections by
TREC-licensed inspectors. An inspection addresses only those components and conditions that are present, visible, and
accessible at the time of the inspection. While there may be other parts, components or systems present, only those items
specifically noted as being inspected were inspected. The inspector is not required to move furnishings or stored items. The
inspection report may address issues that are code-based or may refer to a particular code; however, this is NOT a code
compliance inspection and does NOT verify compliance with manufacturer’s installation instructions. The inspection does
NOT imply insurability or warrant ability of the structure or its components. Although some safety issues may be addressed
in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential
hazards.
In this report, the inspector will note which systems and components were Inspected (I), Not Inspected (NI), Not Present
(NP), and/or Deficient (D). General deficiencies include inoperability, material distress, water penetration, damage,
deterioration, missing parts, and unsuitable installation. Comments may be provided by the inspector whether or not an item
is deemed deficient. The inspector is not required to prioritize or emphasize the importance of one deficiency over another.
Some items reported as Deficient may be considered life-safety upgrades to the property. For more information, refer to
Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I.
This property inspection is not an exhaustive inspection of the structure, systems, or components. The inspection may not
reveal all deficiencies. A real estate inspection helps to reduce some of the risk involved in purchasing a home, but it cannot
eliminate these risks, nor can the inspection anticipate future events or changes in performance due to changes in use or
occupancy. It is recommended that you obtain as much information as is available about this property, including any seller’s
disclosures, previous inspection reports, engineering reports, building/remodeling permits, and reports performed for or by
relocation companies, municipal inspection departments, lenders, insurers, and appraisers. You should also attempt to
determine whether repairs, renovation, remodeling, additions, or other such activities have taken place at this property. It is
not the inspector’s responsibility to confirm that information obtained from these sources is complete or accurate or that this
inspection is consistent with the opinions expressed in previous or future reports.
Promulgated by the Texas Real Estate Commission(TREC) P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or (512)459-6544
(http:www.trec.state.tx.us). REI 7-2 (8/09)
3. Report Identification: 500 Sea Breeze Dr Page 3 of 39
ITEMS IDENTIFIED IN TH3E REPORT DO NOT OBLIGATE ANY PARTY TO MAKE REPAIRS OR TAKE OTHER
ACTIONS, NOR IS THE PURCHASER REQUIRED TO REQUEST THAT THE SELLER TAKE ANY ACTION. When a
deficiency is reported, it is the client’s responsibility to obtain further evaluations and/or cost estimates from qualified service
professionals. Any such follow-up should take place prior to the expiration of any time limitations such as option periods.
Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve additional repair
costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the structure or
systems and add to the original repair costs. The inspector is not required to provide follow-up services to verify that proper
repairs have been made.
Property conditions change with time and use. For example, mechanical devices can fail at any time, plumbing gaskets and
seals may crack if the appliance or plumbing fixture is not used often, roof leaks can occur at any time regardless of the
apparent condition of the roof, and the performance of the structure and the systems may change due to changes in use or
occupancy, effects of weather, etc. These changes or repairs made to the structure after the inspection may render
information contained herein obsolete or invalid. This report is provided for the specific benefit of the client named above and
is based on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report may
provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the
meaning of the information in this report. It is recommended that you hire a licensed inspector to perform an inspection to
meet your specific needs and to provide you with current information concerning this property.
ADDITIONAL INFORMATION PROVIDED BY INSPECTOR:
Termite-WDI (Wood Destroying Insect or Organism) Inspection is NOT provided in this report. This
report is NOT a complete list of repairs and is limited to those items that are readily accessible at time of
inspection. Paint, Floor coverings, and other Cosmetic Items are specifically excluded from this report.
This Inspection-Report does NOT include Mold Testing, Microbial and/or Bio-growth Identification. This
inspection does NOT include any form of Heating and Cooling System(s) warranty and/or guarantee.
This report cannot, and does NOT represent operational performance, warranties, or condition(s) of any
items after the date and time of inspection
4. Report Identification: 500 Sea Breeze Dr Page 4 of 39
I=Inspected NI=Not Inspected NP=Not Present D=Deficiency
I NI NP D
I. STRUCTURAL SYSTEMS
A. Foundations
Type of Foundation: SLAB-ON-GRADE
Columns or Piers: Not present
Vantage point from which the crawlspace space was inspected: NO CRAWL SPACE
Comments:
(1) Planting beds were installed against foundation wall at sides and rear of structure. Irrigating planting
beds installed next to the structure may introduce excessive amounts of moisture to soil supporting the
foundation. This condition can cause foundation and other structural damage from undermining, heaving or
settling, depending on soil composition, moisture content and other conditions.(Picture 1)
A. Picture 1
(2) FOUNDATION PERFORMANCE OPINION: The visible portions of the concrete slab foundation
appeared to be in serviceable condition and is performing the function intended at the time of this
inspection. Most of the slab under floor coverings were not visible at time of inspection.
Note: Weather conditions, drainage, leakage, and other adverse factors are able to effect structures, and
differential movements are likely and/or can occur. The inspectors opinion is based on visual observations
of accessible and unobstructed areas of the structure at the time of the inspection. Future performance of
the structure cannot be predicted or warranted.
SUGGESTED FOUNDATION MAINTENANCE & CARE - Proper drainage and moisture maintenance to
all types of foundations due to the expansive nature of the area load bearing soils. Drainage must be
directed away from all sides of the foundation with grade slopes. In most cases, floor coverings and/or
stored articles prevent recognition of signs of settlement - cracking in all but the most severe cases. It is
important to note, this was not a structural engineering survey nor was any specialized testing done of any
sub-slab plumbing systems during this limited visual inspection, as these are specialized processes
requiring excavation. In the event that structural movement is noted, client is advised to consult with a
Structural Engineer who can isolate and identify causes, and determine what corrective steps, if any,
should be considered to either correct and/or stop structural movement.
B. Grading & Drainage - Comments:
5. Report Identification: 500 Sea Breeze Dr Page 5 of 39
I NI NP D
(1) The gutters have debris and roofing aggregate in areas around structure. The debris in gutters can
also conceal rust, deterioration, or leaks that are not visible until cleaned, in order to find any conditions
that may exist.(Picture 1)
NOTE: The gutters appear intact, but since we are not allowed to test the rain gutters for leaks, I am still
unable to determine if gutters leak at seams or spills water.
B. Picture 1
(2) Downspout attachment detached from rain gutter system at rear of structure. Recommend
reattaching downspout drains as necessary for normal function.(Picture 2)(Picture 3)
B. Picture 2 B. Picture 3
C. Roof Covering Materials
Type (s) of Roof Covering: ARCHITECTURAL, ASPHALT COMPOSITION
Viewed From: Walked roof
Roof Ventilation: Gable vents, Soffit Vents (Air Inlet), Turbines
Comments:
(1) Nail heads and/or fasteners exposed to weather at peak of roof and around vent flashings. Nail
fasteners (Nail-heads) can erode away allowing flashing and/or shingles to come loose if siliconized roof
caulking is not applied.(Picture 1)(Picture 2)(Picture 3)
6. Report Identification: 500 Sea Breeze Dr Page 6 of 39
I NI NP D
C. Picture 1 C. Picture 2 C. Picture 3
(2) Because of the many variables which affect the lifespan of roof-covering materials, the Inspector does
not provide an estimate of the expected long-term service life of any roof-covering materials. This is in
accordance with all inspection industry Standards of Practice.
The following factors affect the lifespan of roof-covering materials:
- Roofing material quality: Better quality materials generally last longer.
- Installation method: Improper installation may reduce lifespan.
- Number of layers: Roofs installed over existing roofs will have reduced lifespan.
- Structure orientation: South-facing roofs will have shorter lifespans.
- Degree of roof slope: Flatter roofs will have shorter lifespans.
- Climate zone (snow & rain): Harsh climates shorten roof lifespans.
- Temperature swings: climates with large daily temperature differentials (within 24-hour cycles) will shorten
roof lifespans.
- Homesite conditions (overhanging tree branches, wind, etc.)
- Roof color: Darker roofs absorb more heat which shortens roof lifespan.
- Elevation: Homes at higher elevations are exposed to more ultra violet (UV) light, which shortens roof
lifespan.
- Home orientation: Roofs which receive more sun deteriorate more quickly than roofs which receive less
sun.
- Roof structure ventilation: Poor ventilation shortens roof lifespans.
- Quality of maintenance: Poor maintenance will reduce lifespan.
NOTE: BE ADVISED, THAT IT IS A GOOD IDEA TO CONSULT WITH YOUR INSURANCE UNDERWRITER FOR INSURABILITY
OF THIS ROOF COVERING AND/OR RELATED COMPONENTS BEFORE PURCHASING AND/OR MOVING INTO HOME. THE
7. Report Identification: 500 Sea Breeze Dr Page 7 of 39
I NI NP D
HOME INSPECTOR MAKES EVERY EFFORT TO DELIGENTLY OBSERVE AND REPORT DAMAGE, IMPROPERLY INSTALLED
MATERIALS, AND UNSAFE CONDITIONS ON THE ROOF COVERING. SOME AREAS THAT ARE NOT VISIBLE OR ACCESSIBLE
CAN GO UNDETECTED AND CAN POSSIBLY LEAK AFTER THE INSPECTION, EVEN IF THE ROOF COVERING APPEARS TO
BE FUNCTIONING NORMALLY. THEREFORE, NO REPRESENTATION OF WARRANTIES ARE IMPLIED ON THIS ROOF
COVERING. IT IS ENTIRELY UP TO THE HOME OWNER TO HIRE EXPERTS KOWLEGABLE AND ABLE TO MAKE
APPROPRIATE REPAIRS IF NECESSARY.
D. Roof Structure & Attic
Viewed From: Walked, Some areas not accessible
Roof Structure: Rough Framing, 2 x 10 Ridge Beams, 2 x 6 Ridge Rafters, 2 X 8 Rafters, 2 x 4 Collar-
Ties, 2 x 6 Purlins, 2 x 4 Purlin supports(With stiff-backs), Plywood Sheathing, Some areas not visible
Attic Insulation: Blown
Approximate Average Depth of Insulation: less than 6 inches, Inadeqaute
Approximate Average Thickness of Vertical Insulation: NOT VISIBLE (Behind walls)
Attic info: Pull Down stairs
Comments:
(1) The pull down stairs have loose hardware at room add-on location. Injury could result if not
repaired.(Picture 1)
D. Picture 1
(2) Insulation missing at back of attic stair access inside room add-on location. Lack of insulation can
affect efficiency of heating and cooling levels within the structure if not applied. Recommend adding
insulation as necessary.(Picture 2)
D. Picture 2
(3) Scuttle opening into attic space was inaccessible due personal belongings and furniture in way of
access at guest house location. Since we are not allowed to move or dismantle personal items. I am unable
8. Report Identification: 500 Sea Breeze Dr Page 8 of 39
I NI NP D
to determine the condition or deficiencies of attic structure and related components at time of this
inspection. (Picture 1)
D. Picture 3
(4) Insufficient amounts of insulation observed inside attic space, with less than 6 inches in some
locations. Recommend adding insulation of a minimum of 8-10 inches or as necessary for normal
function.(No photo)
E. Walls (Interior & Exterior)
Wall Structure: Wood studs (Not visible)
Comments:
(1) Trim separation and gap openings in caulking-seams on soffit, eave boards, and at horizontal siding
in various locations outside of structure. Openings beginning to develop in siding where plant hooks may
not be securely attached to the header at front porch.(Picture 1)(Picture 2)
NOTE: Open penetrations may allow moisture, insects, and/or pests to enter if not corrected and
maintained as needed. Therefore, it is recommended sealing these areas as necessary to prevent further
deterioration.
E. Picture 1 OPENINGS IN E. Picture 2 FRONT PORCH E. Picture 3 SEAM OPENINGS
SOFFIT
(2) Vegetation growing against the exterior walls may introduce pests and/or accelerate deterioration of
the exterior wall covering by retaining moisture. Watering this vegetation will introduce moisture to the soil
which may eventually reach the foundation. Moisture in soil supporting the foundation can affect the ability
of the foundation to support the weight of the structure above and can cause damage from soil heaving or
settling, depending on soil composition and other conditions.(Picture 4)
NOTE: The Inspector recommends removal of the vegetation from exterior walls. Consider replacement
with vegetation having low water requirements.
9. Report Identification: 500 Sea Breeze Dr Page 9 of 39
I NI NP D
E. Picture 4 TRIM BACK 3-6"
(3) Unfinished wall surfaces observed near ceiling inside front bedroom at guest house location.
Previous drywall repairs can indicate possible water penetration(s) may have occurred and could return.
Therefore, it is recommended to monitor affected areas and correct as necessary.(Picture 5)
E. Picture 5 GUEST HOUSE
BEDROOM
F. Ceilings & Floors
Floor Structure: CONCRETE SLAB, POST-TENSION-CABLE-SYSTEM (PTS)
Floor System Insulation: NOT VISIBLE
Ceiling Structure: 2X6, &, 2 X 8, CEILING JOISTS (Where visible)
Comments:
(1) THIS REPORT DOES NOT INCLUDE THE INSPECTION OF COSMETIC DAMAGE AND/OR THE CONDITION OF FLOORS,
WALLS, CEILING TEXTURE AND PAINT COVERINGS, STAINS, OR OTHER SURFACES ON CABINETS, COUNTERTOPS AND
PROVIDE AN EXHAUSTIVE LIST OF LOCATIONS OF WATER PENETRATIONS. (535.228 Standards of Practice. Section j,
Paragraphs 1-2)
(2) Caulking separation in seams at panel board attachment points around outside of structure.
Recommend adding siliconized caulking as necessary when openings occur.(Picture 1)
F. Picture 1
10. Report Identification: 500 Sea Breeze Dr Page 10 of 39
I NI NP D
G. Doors (Interior & Exterior) - Comments:
Doorway threshold is unfinished and baseboard materials missing at the master bathroom. This can be
a tripping hazard if not corrected. Recommend installing the proper threshold, transitions, and baseboard
materials as necessary for normal function.(Picture 1)
G. Picture 1
H. Windows - Comments:
(1) Most window exteriors appeared to be in serviceable condition at the time of the inspection. Inspection
of window exteriors typically includes examination of exterior sash and sill condition, flashing above window
(presence and condition), steel lentils or brick-ledge (where applicable), moisture-intrusion integrity.
NOTABLE EXCEPTIONS TO INSPECTING THESE WINDOWS ARE LIMITED TO IDENTIFYING, ISOLATING, AND/OR
DETERMINING LIFE EXPECTANCY OF DOUBLE-PANED WINDOWS OR IF THEY WILL BECOME FOGGED OR ARE VOIDED.
SOME DOUBLE OR THERMAL-PANE WINDOWS MAY LOSE THEIR SEALS LATER ON DOWN THE LINE, WHERE FOGGING
AND/OR CONDENSATION BUILD-UP MAY APPEAR AND DISAPPEAR AS TEMPERATURE AND HUMIDITY CHANGES OCCUR.
SOME WINDOWS WITH LOST SEALS MAY NOT HAVE BEEN EVIDENT AT THE TIME OF THE INSPECTION. THEREFORE,
WINDOWS ARE ONLY CHECKED FOR OBVIOUS FOGGING. IF SOME SEALS ARE NOTED, RECOMMEND ALL WINDOWS BE
CHECKED BY A SPECIALIST FOR ANY FURTHER LOST SEALS BETWEEN PANES
NOTE: SIGNS OF LOST SEALS IN THERMAL PANE WINDOWS MAY APPEAR AND DISAPPEAR AS
TEMPERATURE AND HUMIDITY CHANGES. SOME WINDOWS WITH LOST SEALS MAY NOT HAVE
BEEN EVIDENT AT THE TIME OF THE INSPECTION. THEREFORE, WINDOWS ARE ONLY CHECKED
FOR OBVIOUS FOGGING. IF SOME SEALS ARE NOTED, RECOMMEND ALL WINDOWS BE
CHECKED BY A SPECIALIST FOR ANY FURTHER LOST SEALS BETWEEN PANES.
(2) Air leakage can develop around window components where insulation and caulking should be
applied. Methods used to prevent air leakage at windows typically include installation of a foam sealant
around windows. Confirmation of effective installation of windows against air leakage would require blower
door testing or invasive methods, both of which are beyond the scope of the General Home Inspection.
(Picture 1)
NOTE: Homes without an effective seal against air leakage at windows will incur higher annual heating/
cooling costs and occupants may experience lower comfort levels than with a similar home which is
effectively sealed.
11. Report Identification: 500 Sea Breeze Dr Page 11 of 39
I NI NP D
H. Picture 1 OPENINGS AROUND
WINDOWS
I. Stairways (Interior & Exterior) - Comments:
Not present
J. Fireplace / Chimney
Chimney (exterior): METAL FLUE PIPE, ATTACHED METAL CHIMNEY-CAP
Operable Fireplaces: None
Types of Fireplaces: SOLID FUEL WOOD STOVE
Number of Woodstoves: One
Comments:
Wood stove and chimney-flue should be cleaned by a licensed chimney sweeper professional and
evaluated for leakage as needed for safety before further usage.(Picture 1)
J. Picture 1
K. Porches, Balconies, Decks and Carports - Comments:
(1) Small stress cracks in concrete patios are common, due to lack of expansion joints and are considered
cosmetic. The appearance of settlement cracks in concrete patio does not appear to affect foundation
performance at time of this inspection.(Picture 1)
12. Report Identification: 500 Sea Breeze Dr Page 12 of 39
I NI NP D
K. Picture 1
(2) The patio cover appeared to be in serviceable condition at the time of the inspection.
Inspection of the patio cover typically includes examination of the following…
• attachment to home
• structural integrity
• post bases (for wood decay)
L. Other - Comments:
The home was occupied during inspection with furniture and personal storage items in areas where
accessibility could not be obtained. Since I am not allowed to move furniture or personal belongings,
condition(s) of areas behind these items are unknown.
REI 7-2 (8/09)
13. Report Identification: 500 Sea Breeze Dr Page 13 of 39
I=Inspected NI=Not Inspected NP=Not Present D=Deficiency
I NI NP D
II. ELECTRICAL SYSTEMS
A. Service Entrance and Panels
Electrical Service Conductors: BELOW GROUND
Panel Capacity: (2) 200 AMP Service Panels, (1) 100 AMP SUB-PANEL
Grounding electrode sytem and bonding: NOT VISIBLE
Panel Type: CIRCUIT BREAKERS
Comments:
(1) Two 200amp Service panel boxes are located inside garage room add-on and at the metal garage
location in back of structure. One 100 amp sub-panel box is located at outside metal horse barn or stable.
(2) Voltage readings at the service panels were 124.0 - 124.1 Volts and appears to be performing as
intended at time of inspection.
(3) One service panel screw missing in panel-box at room add-on location. Recommend installing a
non-pointed screw approved for electrical use.(Picture 1)
A. Picture 1
(4) Combustible materials observed inside sub-panel box at horse stable should be removed. Plug
covers or breakers missing over charged circuitry components can be hazardous if not corrected.
Recommend service as necessary for safety.(Picture 2)
A. Picture 2 SUB-PANEL IN
STABLES
(5) Some labels are present, but are illegible or confusing at service panels inside garage and stable
locations. Recommend correcting for safety reasons.(Picture 3)
14. Report Identification: 500 Sea Breeze Dr Page 14 of 39
I NI NP D
A. Picture 3
B. Branch Circuits - Connected Devices, and Fixtures
Branch wire 15 and 20 AMP: COPPER
Type of Wiring: "ROMEX" WIRE CONDUCTORS
GFCI (Ground Fault Circuit Iterruptors) locations: BATHROOM(S), GARAGE, OUTDOOR, KITCHEN
COUNTERTOP, NOT PRESENT IN OTHER REQUIRED LOCATIONS
AFCI (Arch Fault Circuit Iterruptors) locations: NOT PRESENT AT ALL REQUIRED LOCATIONS
Comments:
(1) The indoor smoke detector(s) should have new battery back-up installed and tested at common
hallway to bedrooms and inside living areas as necessary for safety.(Picture 1)
B. Picture 1
(2) Cover plates damaged and missing in various electrical outlet locations inside main structure and at
metal garage. Shock or personal injury can occur if not corrected.(Picture 2)(Picture 3)(Picture 4)(Picture
5)
B. Picture 2 Garage room add-on B. Picture 3 Upstairs attic B. Picture 4 Metal Garage
15. Report Identification: 500 Sea Breeze Dr Page 15 of 39
I NI NP D
B. Picture 5 Metal garage
(3) Wire-stops (bushing protectors) missing around wire conductors, where sharp metal edges can cut
into sheathing. Plug covers are also needed where openings into panel boxes are present. Electrical
issues can be hazardous until corrected and should be performed by a certified electrical
contractor.(Picture 6)(Picture 7)(Picture 8)(Picture 9)(Picture 10)(Picture 11)(Picture 12)(Picture 13)
B. Picture 6 Panel Box at House B. Picture 7 Panel Box at House B. Picture 8 Panel Box at
detached garage
B. Picture 9 No wire-stop at metal B. Picture 10 Panel Box at B. Picture 11 Panel Box at
boxes detached garage detached garage
B. Picture 12 Panel Box at B. Picture 13 No wire stop at well
detached garage pump
(4) Electrical outlets under bar and at metal garage are not GFCI (Ground Fault Circuit Interrupter)
protected, but were operable at time of this inspection. Although, GFCI protection of electrical circuits may
not have been required at the time in which this home was built, as general knowledge of safe building
16. Report Identification: 500 Sea Breeze Dr Page 16 of 39
I NI NP D
practices has improved with the passage of time and building standards have changed to reflect current
understanding.(Picture 14)(Picture 15)
NOTE: This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets.
2. Replacing the electrical circuit outlet located closest to the main electrical service panel with a GFCI
outlet.
3. Replacing the breaker currently protecting the electrical circuit that contains these outlets with a GFCI
breaker.
B. Picture 14 NO GFCI UNDER B. Picture 15 NO GFCI AT METAL
BAR GARAGE
(5) Open wire splice connections observed at each fluorescent light fixture location inside metal
garage. According to electrical standards, wire connections should terminate inside an approved junction-
box as necessary for safety.(Picture 16)
B. Picture 16 Missing J-Boxes at
Metal Garage Lighting
(6) Breaker amperages to the main outdoor AC condensing unit was rated at 40 max. amps, according
to manufacturer's requirements. The maximum amps at the breaker switch location inside structure was 60
amps. Max. Breaker Amperages at the AC condensing unit should match breaker amperage at the panel.
Therefore, a higher rated breaker may not trip as needed in case of an emergency. Breaker replacement
at the panel-box may be necessary and should be further evaluated and/or serviced by a qualified Heating
and Cooling expert.(Picture 17)
17. Report Identification: 500 Sea Breeze Dr Page 17 of 39
I NI NP D
B. Picture 17 Breaker to Main Condensing-unit
(7) Multiple GFCI (Ground Fault Circuit Interrupter) protected outlets applied on the same circuit at
kitchen counter-top location. Electrical standards require only one GFCI outlet per "breaker-leg" is needed,
and should be installed at the first receptacle from the service panel. Recommend replacing GFCI outlet
with a standard receptacle as necessary for normal function.(Picture 18)(Picture 19)
B. Picture 18 OPEN GROUND
B. Picture 19 Install closest to panel
(8) Light bulb needed or fixture repair at outdoor light fixture in rear of structure. Some outdoor lighting
did not function when tested.(Picture 20)
B. Picture 20 Outdoor lighting
(9) The electrical system does not have AFCI (Arc-fault circuit interrupters) protection at required
locations in bedrooms and living areas as necessary for safety.This standard was not enforced and
may not have been required when the home was constructed. AFCI Protected outlets were effectively
introduced January 1st, 2002, and was mandated by the NEC (National Electric Code) to protect 15 and
20 amp branch circuits servicing bedrooms in new construction. This is not a new home, so simply
18. Report Identification: 500 Sea Breeze Dr Page 18 of 39
I NI NP D
consider the benefits of installing them as necessary for safety when children are present.(Picture
21)(Picture 22)
NOTE: AFCI breakers are now required to be installed in all living and bedroom circuits. These safety
devices are intended to detect the kinds of electrical arcs that can cause fire and/or personal injury. An
AFCI breaker is designed to trip when it detects a dangerous arc, either in the house wiring, when hot's
and neutrals are accidentally crossed, defects in an extension cord, and/or appliance.
B. Picture 22 Missing AFCI
Breakers
B. Picture 21 Why AFCI? Safety!
REI 7-2 (8/09)
19. Report Identification: 500 Sea Breeze Dr Page 19 of 39
I=Inspected NI=Not Inspected NP=Not Present D=Deficiency
I NI NP D
III. HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS
A. Heating Equipment
Type of System: WHOLE HOUSE, Heat Pump Forced Air (also provides cool air)
Energy Source: ELECTRIC
Number of Heat Systems (excluding wood): Three
Comments:
Heat temperature readings with the thermostats set on heat mode from read 110-126 and is heating
within temperature(s) allowed for normal operation.
B. Cooling Equipment
Type of System: Air conditioning equipment:, CENTRAL, SPLIT SYSTEM (Air handler / Condensing
Unit)
Number of AC Only Units: Three
Comments:
(1) The air conditioning equipment is a split system, in which the cabinet housing, the compressor, cooling
fan, and condensing coils, were located physically apart from the evaporator coils. As is typical with split
systems, the compressor/condenser cabinet was located at the home's exterior, so that the heat is
collected or absorbed from inside the home and then released to the outside by conduction. The indoor
evaporator coils are designed to collect heat from the interior, cool it down with refrigerant (Conduction),
and then return the conditioned-cooler air back into the room by convection.(Picture 1)(Picture 2)
The ambient air test was performed by using thermometers on the air handler portion of Air conditioner
units, to determine if the difference in temperatures of the supply and return air are between 14 degrees
and 22 degrees which indicates that the units are cooling as intended fro normal operation.
x Unit #1 - Supply Air Temp: 60-62 Return Air Temp: 78 Temp. Differential: 18 Degrees F (Normal)
x Unit #2 - Supply Air Temp: 67-72 Return Air Temp: 82 Temp. Differential: 15 Degrees F (Normal)
Air Conditioning equipment located at the metal garage location:
x Unit #3 - Supply Air Temp: 66-68 Return Air Temp: 84 Temp. Differential: 18 Degrees F (Normal)
20. Report Identification: 500 Sea Breeze Dr Page 20 of 39
I NI NP D
B. Picture 1
B. Picture 2
(2) Openings in the evaporator-coil cabinet at the air-handler unit will introduce conditioned air into the
attic space and increase energy loss if not corrected. Recommend installing a plug drain cover as
needed.(Picture 3)
B. Picture 3
(3) Recommend installing a float valve device that signals the thermostat to shut off the system in
case primary drain line blockage. This can protect the evaporator coils from damage and prolong life
expectancy of the cooling system if correctly applied.(Picture 4)(Picture 5)
B. Picture 4
B. Picture 5
(4) 3/4 inch PVC drain line missing to drip pan supplying service to the room add-on location.
Secondary drain source should be installed and plumbed to terminate at an outdoor soffit-panel
location.(Picture 6)
21. Report Identification: 500 Sea Breeze Dr Page 21 of 39
I NI NP D
B. Picture 6 DRIP PAN AT SMALL
AC
C. Duct System, Chases, and Vents
Ductwork: Insulated, Flex ducting
Filter Type: Disposable
Comments:
Flex ducting should be hung properly from rafters and not lay directly on ceiling joists. Noise vibration,
eventual collapse and deterioration of the bottom sides of the ductwork can occur if not properly hung as
suggested by today's standards and/or manufacturer's requirements.(Picture 1)(Picture 2)
NOTE: Ductwork that is not properly hung from rafters may have not been a standard when the home
was built but can be corrected if necessary.
C. Picture 1 C. Picture 2
REI 7-2 (8/09)
22. Report Identification: 500 Sea Breeze Dr Page 22 of 39
I=Inspected NI=Not Inspected NP=Not Present D=Deficiency
I NI NP D
IV. PLUMBING SYSTEM
A. Water Supply System and Fixtures
Water Source: Well or Spring, Public
Location of water meter: Street
Location of main water supply valve: Unable to locate
Static water pressure reading: 46 pounds/square inch
Water Filters: (We do not inspect filtration systems)
Comments:
(1) Main water meter is buried under soil at street in front of property. Recommend removing soils as
necessary for normal function.(Picture 1)
A. Picture 1
(2) The toilet is loose at floor at master bathroom location. Repairs may involve re-setting the toilet on
a new wax seal. I recommend a qualified licensed plumber repair or correct as needed.(Picture 2)
A. Picture 2
(3) Anti-siphoning devices or "vacuum-breakers" missing at both outdoor faucet locations in front and
back of structure. Vacuum breakers installed on outdoor "hose-bibs" can protect clean potable water lines
from contamination that can occur when fixtures are in use. Recommend repair or replace as
necessary.(Picture 3)(Picture 4)
23. Report Identification: 500 Sea Breeze Dr Page 23 of 39
I NI NP D
A. Picture 3 A. Picture 4
(4) I could not locate the main shut-off for water, or is buried under soil at front of structure. Please
ask the current owners for the location. Otherwise, you will need to use a water key at the street meter or
have a plumber install one as needed.(No photo)
B. Drains, Waste, and Vents
Washer Drain Size: 2" Diameter
Plumbing Waste: PVC
Comments:
The General Home Inspection is a visual inspection of the home systems and their visible, accessible
components. I evaluate drain pipes by operating and observing each operable home plumbing fixture to
ensure proper drainage at each fixture at the time of the inspection. Blockages can occur between the
time the home is inspected and the time you move in, sometimes due to cleaning activities. Blockages
will eventually occur, usually relative in severity to the age of the plumbing system, and will range from
minor blockages of branch lines, or at the traps beneath sinks, tubs, and showers, to major blockages in
the main sewer line. Minor blockages are usually easily cleared, either by chemical or mechanical means
or by removing and cleaning the traps. The Inspector recommends that you ask the sellers if they have
ever experienced any drainage problems. If the home is older, you may wish to have the main waste line
video-scanned before the expiration of you Inspection Objection Deadline, as replacement can be
expensive.
C. Water Heating Equipment
Energy Source: Electric (slow recovery)
Capacity: (2) 40 Gallon, 1-50 Gallon Unit at Garage
Water Heater Location: Attic, Closet downstairs, Garage
Comments:
(1) Water heater is located directly on the floor of the metal garage where a vehicle can come into
contact with unit. Standards require that all water heaters located inside garages should be installed no
less than 18 inches off the floor or as necessary for safety. Due to deficiencies noted, it is recommended
that further evaluation(s) and/or repairs be performed by a qualified person and/or certified plumbing
contractor.(Picture 1)
24. Report Identification: 500 Sea Breeze Dr Page 24 of 39
I NI NP D
C. Picture 1
(2) The lifespan of water heaters depends upon the following:
- The quality of the water heater
- The chemical composition of the water
- The long-term water temperature settings
- The quality and frequency of past and future maintenance
NOTE: I recommend flushing the water heater once a year and replacing the anode every four years.
You should keep the water temperature set at a minimum of 110 degrees Fahrenheit to kill microbes and
a maximum of 130 degrees to prevent scalding.
D. Hydro-Massage Therapy Equipment - Comments:
(1) Sealant should be applied around openings where water can enter behind the hydro-tub as
necessary for normal function. Recommend applying siliconized caulking as needed.(Picture 1)
D. Picture 1
(2) Unable to access pump compartment to the hydro-tub without dismantling or prying open the
panel cover. Since I am not allowed to dismantle panels and covers, knowing the condition of pump,
related components, and proper grounding for safety is unknown at time of this inspection.(Picture 2)
26. Report Identification: 500 Sea Breeze Dr Page 26 of 39
I=Inspected NI=Not Inspected NP=Not Present D=Deficiency
I NI NP D
V. APPLIANCES
A. Dishwasher - Comments:
Dish washing unit performs as intended when set on normal cycle at time of this inspection.
NOTE: We do not inspect inside of unit for cleanliness.
B. Food Waste Disposer - Comments:
Food disposal unit performs as intended under normal operating conditions at time of this inspection.
C. Range Exhaust Vent - Comments:
Range exhaust unit performs as intended under normal conditions at time of this inspection.
D. Ranges, Cooktops and Ovens - Comments:
Temperature reading with thermostat set at 350 degrees, read 352 degrees, and is performing within the
20 degree margin allowed.
NOTE: IF PRESENT, DELAY TIMER AND SELF-CLEANING MODE ARE NOT TESTED.
E. Microwave Oven - Comments:
Microwave leak test reading indicates NO leakage present 0.0 - 0.0 MW/CM2 and is performing the
function intended for normal use.
F. Trash Compactor - Comments:
Not present
G. Mechanical Exhaust Vents and Bathroom Heaters - Comments:
The Exhaust Fan(s) are plumbed to vent inside attic space from all downstairs bathroom locations.
Many homes have their vent pipes poised to vent into attic space, which may have been acceptable by
standards when this home was constructed. Therefore, It is up to you to determine weather or not this is a
concern, or needs further consideration from a general contractor.(Picture 1)(Picture 2)
27. Report Identification: 500 Sea Breeze Dr Page 27 of 39
I NI NP D
G. Picture 1
G. Picture 2
H. Garage Door Operator(s) - Comments:
(1) The garage door will reverse when met with resistance.
(2) The sensors are in place for garage door(s) and will reverse the door.
I. Doorbell and Chimes - Comments:
Door bell did not work when tested at front of home. Standards recommend that a hard-wired door bell
type of system should be present, which are considered more reliable than battery operated units. (Picture
1)
I. Picture 1
J. Dryer Vents - Comments:
Dryer vents should be cleaned as necessary before usage.
REI 7-2 (8/09)
28. Report Identification: 500 Sea Breeze Dr Page 28 of 39
I=Inspected NI=Not Inspected NP=Not Present D=Deficiency
I NI NP D
VI. OPTIONAL SYSTEMS
A. Lawn and Garden Sprinkler System - Comments:
(1) Zones # 3 has a broken and/or damaged sprinkler head(s) at right side (Facing front) of structure.
Recommend service before further usage.(Picture 1)
A. Picture 1 Zone# 3 damaged
head
(2) Zones # 7 has 2 broken and/or damaged sprinkler heads at front of structure. Recommend service
before further usage.(Picture 2)(Picture 3)
A. Picture 2 Zone# 7 damaged A. Picture 3 Zone# 7
heads
(3) Zones # 9 has 2 damaged sprinkler heads at rear of structure. Recommend service before further
usage.(Picture 4)(Picture 5)
A. Picture 4 Zone# 9 damaged A. Picture 5 Zone# 9
heads
B. Swimming Pools, Spas, Hot Tubs, and Equipment
Type of Construction: Not applicable
Comments:
29. Report Identification: 500 Sea Breeze Dr Page 29 of 39
I NI NP D
Not present
C. Outbuildings - Comments:
Performing function intended.
D. Outdoor Cooking Equipment
Energy Source: Not applicable
Comments:
Not present
E. Gas Supply System - Comments:
No gas service to structure at time of inspection.
F. Private Water Wells (A coliform analysis is recommended)
Type of Pump: In-line electrical pump system
Type of Storage Equipment: Tank with Internal Air Bladder System
Comments:
(1) Well pump, pressure tank, and related components appear to be properly installed to manufacturer's
requirements and is performing the functional purpose intended at time of this inspection.(Picture 1)
F. Picture 1
(2) Well water content was tested for 10 different common contaminates that is listed below. Due to
seasonal changes, it is recommended by the EPA that frequent testing of private household wells be
performed accordingly to maintain safe water purity levels. The well water was tested for the following
contaminants:
• Coliform Bacteria ( B): Pathogenic organisms that can cause disease. None allowed for normal
test.
• Pesticides ( Pe): From agricultural uses. Linked to increase cancer rates. Must be below 3 & 4
ppb
• Nitrates ( N): Fertilizer and animal waste. Can cause developmental problems. Must be < 10.0
ppm
• Lead ( Pb): Known to cause developmental harm, neurological and kidney damage. Be below
15 ppb
30. Report Identification: 500 Sea Breeze Dr Page 30 of 39
I NI NP D
• Iron ( Fe): Can leave reddish brown staining. cause brain damage and bone loss. Should be <
0.3 ppm
• Nitrites ( N): From fertilizer and animal waste. Can cause developmental problems. Be below 1.0
ppm
• Hardness ( Hd): Causes lime scale and detergent usage. Should be 50 ppm or less for normal
function.
• PH ( pH): Can cause heavy metal (Lead) leaching and plumbing damage. Should be 6.5 to 8.5
nominal.
• Chlorine ( CL): By-products that can increase cancer risk, bad taste, and smell. Should be below
4 ppm
• Copper ( Cu): High levels can cause gastrointestinal distress. Should be below 1.3 ppm normal
content.
(3) Test results of the contaminate levels on your private household well were as follows:
1. Bacteria; Vial stayed purple after 48 hours which indicates a normal test and no bacteria. OK
2. Pesticides; Test strips indicate less than 3-4 ppb and indicates normal test. OK
3. Nitrates; Test strip indication was 0.5 ppm which indicates a normal test. OK
4. Lead; Test strip indicates less than 3-4 ppb and indicates a normal test. OK
5. Iron; Test strip indicates 0.0 ppm which indicates a normal test. OK
6. Nitrites; Test strip indication was 0 ppm which indicates a normal test. OK
7. Hardness; Test strip indication was 120 ppm and is higher than 50 ppm which indicates positive
test.
8. Ph; Test strip indication of 6.5 indicates a normal test. OK
9. Chlorine; Test strip indication was 0 ppm which indicates a normal test. OK
10. Copper; Test strip indication was 0 ppm which indicates a normal test. OK
To summarize; Your onsite water well is bacteria free, no mineral or pesticides detected and no lead or
ph unbalance was present at time of inspection. Water hardness was detected, which may require the
possible need for a water softener system be installed as necessary for normal function.
G. Private Sewage Disposal (Septic) System
Type of System: Unknown
Location of Drain Field: Unable to determine
Septic Tank: Not Inspected (Below ground)
Comments:
31. Report Identification: 500 Sea Breeze Dr Page 31 of 39
I NI NP D
This inspection did not access the tank into the onsite septic system at rear of main structure. For a more
detailed inspection, I recommend you contact a septic pumping company and have them clean it. At that
time the system can be properly inspected for normal function. This may be especially important, if
recorded documentation on the maintenance history of this system is not available.(Picture 1)(Picture 2)
G. Picture 2 COVERED BY SOIL
G. Picture 1
H. Whole-House Vacuum Systems - Comments:
Appears to be performing the function intended.
I. Other Built-in Appliances - Comments:
Not Applicable
REI 7-2 (8/09)
Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Spec-Pro Inspection Services, LLC
32. Report Identification: 500 Sea Breeze Dr Page 32 of 39
Table of Contents
Cover Page ......................................................................................... 1
I STRUCTURAL SYSTEMS ................................................................ 4
II ELECTRICAL SYSTEMS ............................................................... 13
III HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS19
IV PLUMBING SYSTEM ................................................................... 22
V APPLIANCES ................................................................................ 26
VI OPTIONAL SYSTEMS ................................................................. 28
Table of Contents.............................................................................. 32
Intro Page.......................................................................................... 33
General Summary ............................................................................. 34
33. Report Identification: 500 Sea Breeze Dr Page 33 of 39
Date: 6/18/2010 Time: 10:30 AM Report ID: 10308006
Property: Customer: Real Estate Professional:
500 Sea Breeze Dr John Doe
Dallas TX 75104
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be
considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second
opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or
replacement of item, component or unit should be considered before you purchase the property.
Inspected (I) = I visually observed the item, component or unit and if no other comments were made then it appeared to be
functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was
functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Not Functioning or in need of repair (D) = The item, component or unit is not functioning as intended or needs further
inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need
replacement.
NOTE: Homes more than 6 years old may have areas that are not current in code requirements. This is not a new home and
this home cannot be expected to meet current code standards. While this inspection makes every effort to point out safety
issues, it does not inspect for code. It is common that homes of any age will have had repairs performed and some repairs
may not be in a workmanlike manner. Some areas may appear less than standard. This inspection looks for items that are
not functioning as intended. It does not grade the repair. It is sometimes common to see old plumbing or mixed materials.
Sometimes water signs in crawlspaces or basements could be years old from a problem that no longer exists. Or, it may still
need further attention and repair. Determining this can be difficult in a lived in home. Sometimes homes have signs of
damage to wood from wood eating insects. Having this is typical and fairly common. If the home inspection reveals signs of
damage you should have a pest control company inspect further for activity and possible hidden damage. The home
inspection does not look for possible manufacturer re-calls on components that could be in this home. Always consider hiring
the appropriate expert for any repairs or further inspection.
Standards of Practice: In Attendance: Type of building:
Texas Real Estate Commission (TREC 7A-1 Customer Single Family (1 story)
/ 7-2)
Approximate age of building: Temperature: Weather:
Under 10 Years Over 95 degrees F Hot and Humid
Ground/Soil surface condition: Rain in last 3 days: Radon Test:
Dry No No
Water Test:
Yes, Well water only. (See VI. Optional
Systems, sec. F)
34. Report Identification: 500 Sea Breeze Dr Page 34 of 39
General Summary
Spec-Pro Inspection Services, LLC
P.O. Box 4328
Cedar Hill, TX 75106
817-247-6819
Customer
John Doe
Address
500 Sea Breeze Dr
Dallas TX 75104
The following items or discoveries indicate that these systems or components do not function as intended or adversely
affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent
observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in
proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. This
Summary is not the entire report. The complete report may include additional information of concern to the customer. It is
recommended that the customer read the complete report.
I. STRUCTURAL SYSTEMS
A. Foundations
Inspected, Deficiency
(1) Planting beds were installed against foundation wall at sides and rear of structure. Irrigating planting beds
installed next to the structure may introduce excessive amounts of moisture to soil supporting the foundation. This
condition can cause foundation and other structural damage from undermining, heaving or settling, depending on
soil composition, moisture content and other conditions.(Picture 1)
B. Grading & Drainage
Inspected, Deficiency
(1) The gutters have debris and roofing aggregate in areas around structure. The debris in gutters can also conceal
rust, deterioration, or leaks that are not visible until cleaned, in order to find any conditions that may exist.(Picture 1)
NOTE: The gutters appear intact, but since we are not allowed to test the rain gutters for leaks, I am still unable to
determine if gutters leak at seams or spills water.
(2) Downspout attachment detached from rain gutter system at rear of structure. Recommend reattaching
downspout drains as necessary for normal function.(Picture 2)(Picture 3)
C. Roof Covering Materials
Inspected, Deficiency
35. Report Identification: 500 Sea Breeze Dr Page 35 of 39
I. STRUCTURAL SYSTEMS
(1) Nail heads and/or fasteners exposed to weather at peak of roof and around vent flashings. Nail fasteners (Nail-
heads) can erode away allowing flashing and/or shingles to come loose if siliconized roof caulking is not
applied.(Picture 1)(Picture 2)(Picture 3)
D. Roof Structure & Attic
Inspected, Deficiency
(1) The pull down stairs have loose hardware at room add-on location. Injury could result if not repaired.(Picture 1)
(2) Insulation missing at back of attic stair access inside room add-on location. Lack of insulation can affect
efficiency of heating and cooling levels within the structure if not applied. Recommend adding insulation as
necessary.(Picture 2)
(3) Scuttle opening into attic space was inaccessible due personal belongings and furniture in way of access at
guest house location. Since we are not allowed to move or dismantle personal items. I am unable to determine the
condition or deficiencies of attic structure and related components at time of this inspection. (Picture 1)
(4) Insufficient amounts of insulation observed inside attic space, with less than 6 inches in some locations.
Recommend adding insulation of a minimum of 8-10 inches or as necessary for normal function.(No photo)
E. Walls (Interior & Exterior)
Inspected, Deficiency
(1) Trim separation and gap openings in caulking-seams on soffit, eave boards, and at horizontal siding in various
locations outside of structure. Openings beginning to develop in siding where plant hooks may not be securely
attached to the header at front porch.(Picture 1)(Picture 2)
NOTE: Open penetrations may allow moisture, insects, and/or pests to enter if not corrected and maintained as
needed. Therefore, it is recommended sealing these areas as necessary to prevent further deterioration.
(2) Vegetation growing against the exterior walls may introduce pests and/or accelerate deterioration of the exterior
wall covering by retaining moisture. Watering this vegetation will introduce moisture to the soil which may eventually
reach the foundation. Moisture in soil supporting the foundation can affect the ability of the foundation to support the
weight of the structure above and can cause damage from soil heaving or settling, depending on soil composition
and other conditions.(Picture 4)
NOTE: The Inspector recommends removal of the vegetation from exterior walls. Consider replacement with
vegetation having low water requirements.
(3) Unfinished wall surfaces observed near ceiling inside front bedroom at guest house location. Previous drywall
repairs can indicate possible water penetration(s) may have occurred and could return. Therefore, it is
recommended to monitor affected areas and correct as necessary.(Picture 5)
F. Ceilings & Floors
Inspected, Deficiency
(2) Caulking separation in seams at panel board attachment points around outside of structure. Recommend adding
siliconized caulking as necessary when openings occur.(Picture 1)
G. Doors (Interior & Exterior)
Inspected, Deficiency
Doorway threshold is unfinished and baseboard materials missing at the master bathroom. This can be a tripping
hazard if not corrected. Recommend installing the proper threshold, transitions, and baseboard materials as
necessary for normal function.(Picture 1)
H. Windows
Inspected, Deficiency
(2) Air leakage can develop around window components where insulation and caulking should be applied. Methods
used to prevent air leakage at windows typically include installation of a foam sealant around windows.
Confirmation of effective installation of windows against air leakage would require blower door testing or invasive
methods, both of which are beyond the scope of the General Home Inspection. (Picture 1)
36. Report Identification: 500 Sea Breeze Dr Page 36 of 39
I. STRUCTURAL SYSTEMS
NOTE: Homes without an effective seal against air leakage at windows will incur higher annual heating/cooling
costs and occupants may experience lower comfort levels than with a similar home which is effectively sealed.
II. ELECTRICAL SYSTEMS
A. Service Entrance and Panels
Inspected, Deficiency
(3) One service panel screw missing in panel-box at room add-on location. Recommend installing a non-pointed
screw approved for electrical use.(Picture 1)
(4) Combustible materials observed inside sub-panel box at horse stable should be removed. Plug covers or
breakers missing over charged circuitry components can be hazardous if not corrected. Recommend service as
necessary for safety.(Picture 2)
(5) Some labels are present, but are illegible or confusing at service panels inside garage and stable locations.
Recommend correcting for safety reasons.(Picture 3)
B. Branch Circuits - Connected Devices, and Fixtures
Inspected, Deficiency
(2) Cover plates damaged and missing in various electrical outlet locations inside main structure and at metal
garage. Shock or personal injury can occur if not corrected.(Picture 2)(Picture 3)(Picture 4)(Picture 5)
(3) Wire-stops (bushing protectors) missing around wire conductors, where sharp metal edges can cut into
sheathing. Plug covers are also needed where openings into panel boxes are present. Electrical issues can be
hazardous until corrected and should be performed by a certified electrical contractor.(Picture 6)(Picture 7)(Picture
8)(Picture 9)(Picture 10)(Picture 11)(Picture 12)(Picture 13)
(4) Electrical outlets under bar and at metal garage are not GFCI (Ground Fault Circuit Interrupter) protected, but
were operable at time of this inspection. Although, GFCI protection of electrical circuits may not have been required
at the time in which this home was built, as general knowledge of safe building practices has improved with the
passage of time and building standards have changed to reflect current understanding.(Picture 14)(Picture 15)
NOTE: This can be achieved by:
1. Replacing the current standard outlets with GFCI outlets.
2. Replacing the electrical circuit outlet located closest to the main electrical service panel with a GFCI outlet.
3. Replacing the breaker currently protecting the electrical circuit that contains these outlets with a GFCI breaker.
(5) Open wire splice connections observed at each fluorescent light fixture location inside metal garage. According
to electrical standards, wire connections should terminate inside an approved junction-box as necessary for
safety.(Picture 16)
(6) Breaker amperages to the main outdoor AC condensing unit was rated at 40 max. amps, according to
manufacturer's requirements. The maximum amps at the breaker switch location inside structure was 60 amps.
Max. Breaker Amperages at the AC condensing unit should match breaker amperage at the panel. Therefore, a
higher rated breaker may not trip as needed in case of an emergency. Breaker replacement at the panel-box may
be necessary and should be further evaluated and/or serviced by a qualified Heating and Cooling expert.(Picture
17)
(7) Multiple GFCI (Ground Fault Circuit Interrupter) protected outlets applied on the same circuit at kitchen counter-
top location. Electrical standards require only one GFCI outlet per "breaker-leg" is needed, and should be installed
at the first receptacle from the service panel. Recommend replacing GFCI outlet with a standard receptacle as
necessary for normal function.(Picture 18)(Picture 19)
(8) Light bulb needed or fixture repair at outdoor light fixture in rear of structure. Some outdoor lighting did not
function when tested.(Picture 20)
37. Report Identification: 500 Sea Breeze Dr Page 37 of 39
II. ELECTRICAL SYSTEMS
(9) The electrical system does not have AFCI (Arc-fault circuit interrupters) protection at required locations in
bedrooms and living areas as necessary for safety.This standard was not enforced and may not have been
required when the home was constructed. AFCI Protected outlets were effectively introduced January 1st, 2002,
and was mandated by the NEC (National Electric Code) to protect 15 and 20 amp branch circuits servicing
bedrooms in new construction. This is not a new home, so simply consider the benefits of installing them as
necessary for safety when children are present.(Picture 21)(Picture 22)
NOTE: AFCI breakers are now required to be installed in all living and bedroom circuits. These safety devices are
intended to detect the kinds of electrical arcs that can cause fire and/or personal injury. An AFCI breaker is
designed to trip when it detects a dangerous arc, either in the house wiring, when hot's and neutrals are
accidentally crossed, defects in an extension cord, and/or appliance.
III. HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS
B. Cooling Equipment
Inspected, Deficiency
(2) Openings in the evaporator-coil cabinet at the air-handler unit will introduce conditioned air into the attic space
and increase energy loss if not corrected. Recommend installing a plug drain cover as needed.(Picture 3)
(3) Recommend installing a float valve device that signals the thermostat to shut off the system in case primary
drain line blockage. This can protect the evaporator coils from damage and prolong life expectancy of the cooling
system if correctly applied.(Picture 4)(Picture 5)
(4) 3/4 inch PVC drain line missing to drip pan supplying service to the room add-on location. Secondary drain
source should be installed and plumbed to terminate at an outdoor soffit-panel location.(Picture 6)
C. Duct System, Chases, and Vents
Inspected, Deficiency
Flex ducting should be hung properly from rafters and not lay directly on ceiling joists. Noise vibration, eventual
collapse and deterioration of the bottom sides of the ductwork can occur if not properly hung as suggested by
today's standards and/or manufacturer's requirements.(Picture 1)(Picture 2)
NOTE: Ductwork that is not properly hung from rafters may have not been a standard when the home was built but
can be corrected if necessary.
IV. PLUMBING SYSTEM
A. Water Supply System and Fixtures
Inspected, Deficiency
(1) Main water meter is buried under soil at street in front of property. Recommend removing soils as necessary for
normal function.(Picture 1)
(2) The toilet is loose at floor at master bathroom location. Repairs may involve re-setting the toilet on a new wax
seal. I recommend a qualified licensed plumber repair or correct as needed.(Picture 2)
(3) Anti-siphoning devices or "vacuum-breakers" missing at both outdoor faucet locations in front and back of
structure. Vacuum breakers installed on outdoor "hose-bibs" can protect clean potable water lines from
contamination that can occur when fixtures are in use. Recommend repair or replace as necessary.(Picture
3)(Picture 4)
(4) I could not locate the main shut-off for water, or is buried under soil at front of structure. Please ask the current
owners for the location. Otherwise, you will need to use a water key at the street meter or have a plumber install
one as needed.(No photo)
C. Water Heating Equipment
Inspected, Deficiency
38. Report Identification: 500 Sea Breeze Dr Page 38 of 39
IV. PLUMBING SYSTEM
(1) Water heater is located directly on the floor of the metal garage where a vehicle can come into contact with unit.
Standards require that all water heaters located inside garages should be installed no less than 18 inches off the
floor or as necessary for safety. Due to deficiencies noted, it is recommended that further evaluation(s) and/or
repairs be performed by a qualified person and/or certified plumbing contractor.(Picture 1)
D. Hydro-Massage Therapy Equipment
Inspected, Deficiency
(1) Sealant should be applied around openings where water can enter behind the hydro-tub as necessary for
normal function. Recommend applying siliconized caulking as needed.(Picture 1)
(2) Unable to access pump compartment to the hydro-tub without dismantling or prying open the panel cover. Since
I am not allowed to dismantle panels and covers, knowing the condition of pump, related components, and proper
grounding for safety is unknown at time of this inspection.(Picture 2)
V. APPLIANCES
G. Mechanical Exhaust Vents and Bathroom Heaters
Inspected, Deficiency
The Exhaust Fan(s) are plumbed to vent inside attic space from all downstairs bathroom locations. Many homes
have their vent pipes poised to vent into attic space, which may have been acceptable by standards when this
home was constructed. Therefore, It is up to you to determine weather or not this is a concern, or needs further
consideration from a general contractor.(Picture 1)(Picture 2)
I. Doorbell and Chimes
Inspected, Deficiency
Door bell did not work when tested at front of home. Standards recommend that a hard-wired door bell type of
system should be present, which are considered more reliable than battery operated units. (Picture 1)
VI. OPTIONAL SYSTEMS
A. Lawn and Garden Sprinkler System
Inspected, Deficiency
(1) Zones # 3 has a broken and/or damaged sprinkler head(s) at right side (Facing front) of structure. Recommend
service before further usage.(Picture 1)
(2) Zones # 7 has 2 broken and/or damaged sprinkler heads at front of structure. Recommend service before
further usage.(Picture 2)(Picture 3)
(3) Zones # 9 has 2 damaged sprinkler heads at rear of structure. Recommend service before further
usage.(Picture 4)(Picture 5)
F. Private Water Wells (A coliform analysis is recommended)
Inspected, Deficiency
(3) Test results of the contaminate levels on your private household well were as follows:
1. Bacteria; Vial stayed purple after 48 hours which indicates a normal test and no bacteria. OK
2. Pesticides; Test strips indicate less than 3-4 ppb and indicates normal test. OK
3. Nitrates; Test strip indication was 0.5 ppm which indicates a normal test. OK
4. Lead; Test strip indicates less than 3-4 ppb and indicates a normal test. OK
5. Iron; Test strip indicates 0.0 ppm which indicates a normal test. OK
6. Nitrites; Test strip indication was 0 ppm which indicates a normal test. OK
39. Report Identification: 500 Sea Breeze Dr Page 39 of 39
VI. OPTIONAL SYSTEMS
7. Hardness; Test strip indication was 120 ppm and is higher than 50 ppm which indicates positive test.
8. Ph; Test strip indication of 6.5 indicates a normal test. OK
9. Chlorine; Test strip indication was 0 ppm which indicates a normal test. OK
10. Copper; Test strip indication was 0 ppm which indicates a normal test. OK
To summarize; Your onsite water well is bacteria free, no mineral or pesticides detected and no lead or ph
unbalance was present at time of inspection. Water hardness was detected, which may require the possible need
for a water softener system be installed as necessary for normal function.
Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the
need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use;
Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of
the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that
was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic
items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or
guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or
perform any procedure that may damage the property or its components or be dangerous to the home inspector or other
persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component
that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment,
plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected
adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise,
contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or
remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since
this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed
inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Spec-Pro Inspection Services, LLC