Slide 1 of 25
10/03/2016SYNERGIE-CAD (UK) Greetwell Place, Limekiln Way, Greetwell Road, Lincoln LN2 4US
DESG
SYNERGIE CAD - Test
Slide 1 of 3
SYNERGIE CAD
V93K CTH Configuration
Slide 2 of 25
10/03/2016SYNERGIE-CAD (UK) Greetwell Place, Limekiln Way, Greetwell Road, Lincoln LN2 4US
DESG
Slide 2 of 3
Card Cage 1
Block Instrument
DC-DC Blk B DC PS slot 7,8
DC-DC Blk B DC PS slot 5,6
DC-DC Blk A DC PS slot 3,4
DC-DC Blk A DC PS slot 1,2
DPS
BLOCK B SLOT 8 :-
BLOCK B SLOT 7 :-
BLOCK B SLOT 6 :-
BLOCK B SLOT 5 :-
BLOCK A SLOT 4 :- DPS64
BLOCK A SLOT 3 :-
BLOCK A SLOT 2 :- PS1600
BLOCK A SLOT 1 :- PS1600
CLK DIST/UTIL
Card Cage 2
Block Instrument
DC-DC Blk B DC PS slot 7,8
DC-DC Blk B DC PS slot 5,6
DC-DC Blk A DC PS slot 3,4
DC-DC Blk A DC PS slot 1,2
DPS
BLOCK B SLOT 8 :-
BLOCK B SLOT 7 :-
BLOCK B SLOT 6 :-
BLOCK B SLOT 5 :- MB-AV8+
BLOCK A SLOT 4 :- DPS128HC/HV
BLOCK A SLOT 3 :-
BLOCK A SLOT 2 :- PS1600
BLOCK A SLOT 1 :- PS1600
CLK DIST/UTIL
ADVANTEST 93000 CTH Configuration (DUT Scale) .
SYSTEM
Location
SYNERGIE-CAD
Munich
Smartest Version 7.4.0 RHEL5
 64 DPS 15V/200mA each, can be ganged.
 64 DPS 7V/0.5A, can be ganged to 32A.
 64 DPS 7V/1.5A, can be ganged.
 512 channel PS1600
 256 channel 1.6Gbps, 112MB
 256 channel 100Mbps, 16MB.
 MB-AV8+ 4S/4M, 500Msps AWG enabled.
CTH Configuration.
512 x PS1600 Digital Channels
192 x Device Power Supplies
4S/4M MB-AV8+ Mixed Signal
5V Utility Power
SYNERGIE CAD - Test
Slide 3 of 25
10/03/2016SYNERGIE-CAD (UK) Greetwell Place, Limekiln Way, Greetwell Road, Lincoln LN2 4US
Slide 3 of 3
ADVANTEST 93000 CTH Configuration (DUT Scale - top side) .
CTH Configuration.
512 x PS1600 Digital Channels
192 x Device Power Supplies
4S/4M MB-AV8+ Mixed Signal
5V Utility Power
SYNERGIE CAD - Test

SynergieCAD-V93K-CTH-Configuration_MAR16

  • 1.
    Slide 1 of25 10/03/2016SYNERGIE-CAD (UK) Greetwell Place, Limekiln Way, Greetwell Road, Lincoln LN2 4US DESG SYNERGIE CAD - Test Slide 1 of 3 SYNERGIE CAD V93K CTH Configuration
  • 2.
    Slide 2 of25 10/03/2016SYNERGIE-CAD (UK) Greetwell Place, Limekiln Way, Greetwell Road, Lincoln LN2 4US DESG Slide 2 of 3 Card Cage 1 Block Instrument DC-DC Blk B DC PS slot 7,8 DC-DC Blk B DC PS slot 5,6 DC-DC Blk A DC PS slot 3,4 DC-DC Blk A DC PS slot 1,2 DPS BLOCK B SLOT 8 :- BLOCK B SLOT 7 :- BLOCK B SLOT 6 :- BLOCK B SLOT 5 :- BLOCK A SLOT 4 :- DPS64 BLOCK A SLOT 3 :- BLOCK A SLOT 2 :- PS1600 BLOCK A SLOT 1 :- PS1600 CLK DIST/UTIL Card Cage 2 Block Instrument DC-DC Blk B DC PS slot 7,8 DC-DC Blk B DC PS slot 5,6 DC-DC Blk A DC PS slot 3,4 DC-DC Blk A DC PS slot 1,2 DPS BLOCK B SLOT 8 :- BLOCK B SLOT 7 :- BLOCK B SLOT 6 :- BLOCK B SLOT 5 :- MB-AV8+ BLOCK A SLOT 4 :- DPS128HC/HV BLOCK A SLOT 3 :- BLOCK A SLOT 2 :- PS1600 BLOCK A SLOT 1 :- PS1600 CLK DIST/UTIL ADVANTEST 93000 CTH Configuration (DUT Scale) . SYSTEM Location SYNERGIE-CAD Munich Smartest Version 7.4.0 RHEL5  64 DPS 15V/200mA each, can be ganged.  64 DPS 7V/0.5A, can be ganged to 32A.  64 DPS 7V/1.5A, can be ganged.  512 channel PS1600  256 channel 1.6Gbps, 112MB  256 channel 100Mbps, 16MB.  MB-AV8+ 4S/4M, 500Msps AWG enabled. CTH Configuration. 512 x PS1600 Digital Channels 192 x Device Power Supplies 4S/4M MB-AV8+ Mixed Signal 5V Utility Power SYNERGIE CAD - Test
  • 3.
    Slide 3 of25 10/03/2016SYNERGIE-CAD (UK) Greetwell Place, Limekiln Way, Greetwell Road, Lincoln LN2 4US Slide 3 of 3 ADVANTEST 93000 CTH Configuration (DUT Scale - top side) . CTH Configuration. 512 x PS1600 Digital Channels 192 x Device Power Supplies 4S/4M MB-AV8+ Mixed Signal 5V Utility Power SYNERGIE CAD - Test