This document provides technical data on fire tests performed on Snap-Trak ceiling systems. Several ASTM E-84 tests measured the flame spread index and smoke developed value of Snap-Trak panels with different infill materials. Polyester infill panels had a flame spread index of 25 and smoke developed value of 240. Fiberglass infill panels performed better with a flame spread index of 5 and smoke developed value of 90. All tests showed the Snap-Trak systems passed fire standards. Typical flame spread and smoke developed values are also listed for common infill materials.
1. Section 4: TECHNICAL DATA
_________________________
Complete Fabricated Snap-Trak® System:
FIRE TESTS
ASTM E-84-84a
Surface Burning Characteristics of Building Materials
(FLAME SPREAD INDEX &
SMOKE DEVELOPED
Test Specimen: Snap-Trak®
VALUE)
Infill: Polyester
Flame Spread Index: 25
Tests have been continually Smoke Developed Value: 240
done on our system since
1986 with resultant values Test Specimen: Snap-Trak®
varying dependent upon the Infill: Fiberglass
specific fabric used, type and Flame Spread Index: 5
thickness of acoustical infill Smoke Developed Value: 90
and overall construction of
the panel presented. Test Specimen: Snap-Trak®
Infill: Polyester
All have passed, usually by Flame Spread Index: 6
very generous margins. Smoke Developed Value: 16.5
The test for surface burning
characteristics of building Typical In-Fill Values:
materials that is referred to is
the ASTM E-84-84a. In-Fill Flame Spread Smoke Develop
Polyester: 0 20
Fiberglass: 15 0
Additional fire tests are
available for specific fabrics Specific testing beyond the above information
and specific infills (battings) may be arranged through SoundNice™.