Quidway S2700/S3700/S5700/S6700 Series
Ethernet Switches
V100R006C00SPC800
Upgrade Guide
Issue 01
Date 2011-09-30
HUAWEI TECHNOLOGIES CO., LTD.
Copyright © Huawei Technologies Co., Ltd. 2011. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
i
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide Change History
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
ii
Change History
Changes between document issues are cumulative. The latest document issue contains all the
changes in earlier issues.
Issue 01 (2011-09-30)
This issue is the first official release.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide Contents
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
iii
Contents
Change History................................................................................................................................ ii
1 Before You Start.............................................................................................................................1
1.1 Version Requirements Before Upgrade............................................................................................................1
1.2 Impact of Patch Installation..............................................................................................................................1
1.3 Impact on the System During Installation........................................................................................................1
1.3.1 Impact on the System After Installation..................................................................................................2
1.4 Cautionary Notes Before the Upgrade .............................................................................................................2
2 Upgrade Process ............................................................................................................................4
2.1 Upgrade Flowchart...........................................................................................................................................4
3 Preparations for Upgrade ............................................................................................................5
3.1 Preparation Checklist .......................................................................................................................................5
3.2 Checking the Current System Software Version ..............................................................................................6
3.3 Checking the Running Status of the Device.....................................................................................................6
3.4 Setting Up an Environment for the Upgrade....................................................................................................6
3.5 Obtaining Required Software for the Upgrade.................................................................................................8
3.6 Backing Up the Key Data in the Flash Memory ..............................................................................................9
3.7 Checking the Flash Memory Space..................................................................................................................9
4 Upgrade Operations on a Single Switch ................................................................................12
4.1 Upgrading the Switch to V100R006C00SPC800 Using the Command Line.................................................12
4.2 Upgrading the Switch to the V100R006C00SPC800 Using the BootROM...................................................21
4.2.1 Upgrading the BootROM......................................................................................................................22
4.2.2 Uploading the System Software............................................................................................................26
4.2.3 Specifying the System Software to Be Loaded for Starting the Switch................................................31
4.2.4 Restarting the Switch ............................................................................................................................33
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide Contents
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
iv
4.3 Upgrading the S5700-SI to V100R006C00SPC800 Using the USB Flash Drive ..........................................33
4.3.1 Overview...............................................................................................................................................33
4.3.2 Upgrading the Software Using the USB Flash Drive............................................................................34
5 Upgrade Operations on a Stack................................................................................................38
5.1 Upgrading All Stack Member Switches to V100R006C00SPC800 by Using the Command Line ................38
5.2 Using the Intelligent Upgrade Function .........................................................................................................41
5.2.1 Overview...............................................................................................................................................41
5.2.2 Upgrading a New Member Switch Using the Intelligent Upgrade Function ........................................42
6 Verifying the Upgrade ...............................................................................................................45
6.1 Verification Checklist.....................................................................................................................................45
6.2 Checking the Current System Software Version ............................................................................................45
6.3 Checking the Device Running Status.............................................................................................................46
6.4 Checking the System Configuration...............................................................................................................46
7 Version Rollback.........................................................................................................................48
7.1 S2700 Version Rollback.................................................................................................................................48
7.1.1 Version Rollback Flowchart..................................................................................................................48
7.1.2 Loading the Previous System Software ................................................................................................49
7.1.3 Performing Version Rollback................................................................................................................49
7.1.4 Verifying Version Rollback...................................................................................................................49
7.2 S3700 Version Rollback.................................................................................................................................50
7.2.1 Version Rollback Flowchart..................................................................................................................50
7.2.2 Loading the Previous System Software ................................................................................................50
7.2.3 Performing Version Rollback................................................................................................................51
7.2.4 Verifying Version Rollback...................................................................................................................51
7.3 S5700 Version Rollback.................................................................................................................................51
7.3.1 Version Rollback Flowchart..................................................................................................................51
7.3.2 Loading the Previous System Software ................................................................................................52
7.3.3 Performing Version Rollback................................................................................................................52
7.3.4 Verifying Version Rollback...................................................................................................................52
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 1 Before You Start
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
1
1 Before You Start
1.1 Version Requirements Before Upgrade
T efore uable 1-1 Version requirements b pgrade
Version Upgrade Instruction
S2700, S3700, S5700, S6
V100R006C00SPC300
700
V100R006C00SPC500
V100R006C00SPC600
This version can be directly upgraded to
V100R006C00SPC800.
1.2 Impact
Before you upgrade an earlier version to the V100R006C00SPC800, read this chapter
ing system.
he System During Installation
Impact on Servic
The
of Patch Installation
carefully to understand the possible impacts of the upgrade on the exist
1.3 Impact on t
es
switch will restart during the upgrade and service will be interrupted.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 1 Before You Start
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
2
NOTE
The service interruption time depends on many factors, such as the system software size, upgrade
method, operator's skill, and service configurations. The following service interruption time is for your
owing examples, the switches are not configured and they are not in any stack. In
addition, all these switches can provide the PoE function.
ed by using the BootROM and the system software is uploaded
throu e, the service interruption time is as follows (the baudrate is
52
If the swit ed by using the BootROM and the system software is uploaded
ou TP mode), the service interruption time is as follows:
0: 5.5 minutes
If the ded by using the command line, the service interruption time is as
When the system restarts, the communication between the switch and the NMS is interrupted.
e as the service interruption time.
1.3.1 Impact on the System After Installation
1.4 Cautionar
reference.
In the foll
If the switches are upgrad
gh the serial interfac
11 00):
S2700: 30 minutes
S3700: 37 minutes
S5700: 44 minutes
ches are upgrad
thr gh the network port (F
S2700: 5.5 minutes
S370
S5700: 6 minutes
switches are upgra
follows:
S2700: 3 minutes
S3700: 3 minutes
S5700: 3 minutes
Impact on Network Communication
The communication interruption time is the sam
There is no adverse impact on the system.
y Notes Before the Upgrade
Consider the following cautionary points before performing the upgrade:
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 1 Before You Start
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
3
The flash memory of the S3728/S3752/S2752 can store only one startup file; therefo
delete the current startup file before performing the upgrade. (If there are remaining files
in the flash memory, delete them.)
When you upgrade
re,
the software using the command line, stack upgrade, or USB flash
not saved, the configuration will be lost in the case of
command in the interface view after the upgrade; otherwise, the MAC swap loopback
configuration will be invalid.
After the arp learning dhcp-trigger command is used on a VLANIF interface of the
DHCP relay agent in V100R006, dynamic ARP entries are generated only after DHCP
snooping in the corresponding VLAN or on the physical interface connected to users.
drive, do not copy or delete files.
After the version is upgraded, ensure that the configuration is saved because a later
version is compatible with early versions but an early version is incompatible with later
versions. If the configuration is
version rollback.
If the loopback local swap-mac or loopback remote swap-mac command has been
used on an interface in V100R006 to configure MAC swap loopback, run the start
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 2 Upgrade Process
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
4
2 Upgrade Process
2.1 Upgrade Flowchart
Figure 2-1 Upgrade flowchart
Start
Preparation
Upgrade
See chapter 3
See chapters 4 and 5
Verification See chapter 6 Rollback See chapter 7
Yes
Yes
No
End
Yes
NOTE
In the following chapters, the version is upgraded to V100R006C00SPC800.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
5
3 Preparations for Upgrade
3.1 Prepara
Table 3-1 t
tion Checklist
Upgrade preparation checklis
No. Item Check Point Result
1 Check the system software
version
The system software version is
between V100R006 and
V100R006C00SPC800.
2 running status of normally.Check the
the device
The switch functions
3 ironment for the ent is set up for theSet up an env
upgrade
An environm
upgrade as required.
4 software for uired for the upgrade isObtain required
the upgrade
Software req
obtained.
5 ta in the
flash memory
ory isBack up the key da All the key data in the flash mem
backed up.
6 Check the available space in
the flash memory
The space in the flash memory is
sufficient for storing the system
software package and other files such
as patch files and configuration files.
e.In the following sections, the S2700 is used as an example to describe the upgrad
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
6
3.2 Checking the Current System Software Version
un the display version command to view the version of the system software.
ion
Routing Platform Software
700 V100R006C00)
EDFEA 0(Master) : EDFE uptime is 0 day, 0 hour, 1 minute
3.3 Checking the Running Status of the Device
Status is
Normal, the device can be upgraded.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.4 Setting
Setting Up an Envir ading the System Using TFTP or FTP
Transfer Protocol (FTP) to download the system software, and set it
th e. Figure
s stem using
P
ent for upgrading the system using TFTP
or FTP are as follows:
You can log in to the switch from a PC through the serial interface or Telnet.
The server and the switch can communicate with each other.
Files for the upgrade are stored in the server.
R
<Quidway> display vers
Huawei Versatile
VRP (R) Software, Version 5.70 (S2
Copyright (C) 2003-2010 HUAWEI TECH Co., Ltd.
Quidway S2718TP-SI Routing Switch uptime is 0 day, 0 hour, 1 minute
64M bytes DDR Memory
16M bytes FLASH
Pcb Version : CX22EDFE REV C
Basic BOOTROM Version : 118 Compiled at Nov 4 2009, 17:23:15
Software Version : VRP (R) Software, Version 5.70 (S2700 V100R006C00)
Run the display device command to check the switch running status. If the value of
<Quidway> display device
P S2718TP-EI's Device status:
Slot Sub Type Online Power Register Status Role
0 - 2718F Present PowerOn Registered Normal Master
Up an Environment for the Upgrade
onment for Upgr
In the BootROM menu or the command line view, you can use the Trivial File Transfer
Protocol (TFTP) or File
as e next startup system software. Then restart the device to complete the upgrad
3-1 hows the network diagram for setting up an environment for upgrading the sy
FT or TFTP.
The general requirements for setting up an environm
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
7
Figure 3-1 Network diagram of upgrading the system using TFTP or FTP
Setting Up an Environment for Upgrading the System Using Xmodem
You can upgrade the basic and advanced BootROM software using Xmodem in the basic
BootROM menu; you can upgrade the system software using Xmodem in the BootROM
menu. Figure 3-2 shows the network diagram for setting up an environment for upgrading the
system using Xmodem.
The general requirements for setting up an environment for upgrading the system using
Xmodem are as follows:
The RS-232 serial interface on the PC and the console interface on the switch are
connected through a console cable.
Files for the upgrade are stored on the PC.
Figure 3-2 Network diagram of upgrading the system using Xmodem
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
8
3.5 Obtaining Required Software for the Upgrade
To obtain the required software for the upgrade, contact Huawei technical support personnel.
Table 3-2 Software for different upgrade methods
Upgrade Method Matching Software
Upgrading the version to
V100R006C00SPC800 using the
command line
System software
S2700: S2700-V100R006C00SPC800.CC
S2752:
S2700_52P-V100R006C00SPC800.CC
S3728:
S3700_28TP-V100R006C00SPC800.CC
S3752:
S3700_52P-V100R006C00SPC800.CC
S5700-EI:
S5700EI-V100R006C00SPC800.CC
S5700-SI:
S5700SI-V100R006C00SPC800.CC
S6700: S6700-V100R006C00SPC800.CC
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
9
Upgrade Method Matching Software
Upgrading the version to
V100R006C00SPC800 using
BootROM
BootROM
S2700: S2700_bootrom.bin
S2752: S2700_52P_bootrom.bin
S3728: S3700_28TP_bootrom.bin
S3752: S3700_52P_bootrom.bin
S5700-EI: S5700EI_bootrom.bin
S5700-SI: S5700SI_bootrom.bin
S6700: S6700_bootrom.bin
System software
S2700: S2700-V100R006C00SPC800.CC
S2752:
S2700_52P-V100R006C00SPC800.CC
S3728:
S3700_28TP-V100R006C00SPC800.CC
S3752:
S3700_52P-V100R006C00SPC800.CC
S5700-EI:
S5700EI-V100R006C00SPC800.CC
S5700-SI:
S5700SI-V100R006C00SPC800.CC
S6700: S6700-V100R006C00SPC800.CC
3.6 Backing Up the Key Data in the Flash Memory
You must back up the key data stored in the flash memory before the upgrade. You can
download the data that needs to be backed up to the PC through FTP or TFTP. After the
upgrade, you can reload the backup files to the flash memory. For details, see 4.1 Upgrading
the Switch to V100R006C00SPC800 Using the Command Line.
3.7 Checking the Flash Memory Space
1. Run the dir command in the user view to check whether the flash memory space is sufficient
for the system software. If a stack is established, ensure that all the members in the stack have
enough space.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
10
The preceding information shows that there is 2,266 KB space. If there is enough space,
ignore step 2.
<Quidway> dir
Directory of flash:/
Idx Attr Size(Byte) Date Time(LMT) FileName
0 -rw- 6,458,620 Jan 08 2008 03:35:29 s2700-v100r006c00.cc
1 -rw- 603 Jan 02 2008 02:57:45 vrpcfg.zip
2 -rw- 628 Jan 01 2008 00:00:52 private-data.txt
3 -rw- 6,177,996 Jan 02 2008 02:57:00 s-s2700.cc
14,632 KB total (2,266 KB free)
2. (Optional) Load and activate the patch file S27_37_57-V100R006SPH005.pat.
Before upgrading an S2752 or S3700 to V100R006, delete the current startup file to free up
the flash memory space.
If no system software is stored on the device, do not restart or power cycle the device during
the upgrade. Otherwise, the system may break down. If the device is powered off
unexpectedly during the upgrade, use the BootROM to upgrade the device. If the upgrade
using BootROM fails, contact Huawei engineers.
3. Run the delete command to delete unnecessary files to ensure there is enough space for
storing relevant upgrade files. Before deleting the unnecessary files, ensure that the files are
backed up or are unwanted. The following is an example of deleting the s-s2700.cc file. For
details, see "Managing the File System" in the Quidway S2700/S3700/S5700/S6700 Series
Ethernet Switches Configuration Guide – Basic Configurations.
After you run the delete /unreserved command to delete a file from the flash, the file cannot
be restored; therefore, run this command with caution, and a file backup is recommended.
<Quidway> delete /unreserved s-s2700.cc
Warning: The contents of file flash:/ s-s2700.cc cannot be recycled. Continue? [Y/N]:y
Info: Deleting file flash:/ s-s2700.cc...
Deleting file permanently from flash will take a long time if needed.......
................................................................................
................................................................................
................................................................................
................................................................................
................................................................................
................................................................................su
cceeded.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 3 Preparations for Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
11
----End
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
12
4 Upgrade Operations on a Single Switch
4.1 Upgrading the Switch to V100R006C00SPC800 Using
the Comm
The command line upgrade method has little impact on services; therefore, you are advised to
u operatin
and Line
pgrade an g device by using the command line.
To upgrade the system softwarePurpose
Services are interrupted when the device restarts.Impact
In the scenario where a single device is configured and service
deployment is simple, services are interrupted about three minutes. In
in time increases and the time depends on the complexity of
Time
Required
the scenario where service deployment is complicated, the service
terruption
service.
Requirements ns system software of an earlier version functions
properly.
The available space in the flash memory is sufficient for storing the
system software.
The switch that ru
The S5700/S6700 has a dedicated management interface, namely, MEth. The MEth interface can be
Before the upgrade, use the terminal monitor command to enable the terminal to display logs, traps,
the information center.
u ds to load the system software:
Before the S2752/S3700 is upgraded, you must delete the original startup file. For details on how to
delete the original startup file, see section 3.7 Checking the Flash Memory Space.
The methods of upgrading the system software using command line are similar on the S2700, S3700,
S5700, and the S6700. In the following description, the system software of the S2700 is upgraded.
used as the Layer 3 interface.
and debugging information sent from
Yo can use any of the following metho
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
13
Use the S2700 as the TFTP client.
Use the S2700 as the FTP server.
Method 1: Use th
Use the S2700 as the FTP client.
e S2700 as the TFTP Client
No TFTP client software is installed on the S2700; therefore, the customer needs to buy TFTP client
software and install it. The TFTP32 program is recommended.
1. Configure the TFTP server.
n
he system, for
can manually change
Ru the TFTP server program on the PC and configure the PC:
Click Browse to set the directory for storing the new system software.
The TFTP server address in Server interface is automatically set by t
example, 10.164.30.29. However, if the IP address is incorrect you
it.
Do not stop the TFTP server program when you are backing up data.
2. Back up the system software, configuration file, and patch files to the TFTP server.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
14
Before the backup, check the size of the configuration file. After the backup, compare the size
o files are the same size.
uidway> dir *.cc
te) Date Time(LMT) FileName
0 -rw- 6,472,284 Nov 04 2010 19:43:18 s2700-v100r006c00.cc
uidway> dir *.zip
te) Date Time(LMT) FileName
0 -rw- 589 Nov 04 2010 20:55:54 vrpcfg.zip
uidway> dir *.pat
14,632 KB total (8,228 KB free)
are
atch
-v100r006c00-bak.cc
27_37_57-v100r006sph005.pat
s27_37_57-v100r006sph005-bak.pat
Uploading the file to the remote TFTP server. Please wait...
3. from the server.
<Quidway> tftp 10.164.30.29 get S2700-V100R006C00SPC800.cc
the file from the remote TFTP server. Please wait.../
TFTP: Downloading the file successfully.
If the message "Downloading the file successfully" is displayed, the system software has been
4.
of the original file with the size of the backup file. Ensure that the tw
<Q
Directory of flash:/
Idx Attr Size(By
14,632 KB total (8,228 KB free)
<Q
Directory of flash:/
Idx Attr Size(By
14,632 KB total (8,228 KB free)
<Q
Directory of flash:/
Idx Attr Size(Byte) Date Time(LMT) FileName
0 -rw- 333,436 Jan 29 2010 16:54:40 S27_37_57-V100R006SPH005.pat
Run the following commands on the S2700 to back up the data. The backup system softw
is s2700-v100r006c00-bak.cc, the backup configuration file is vrpcfg-bak.zip, and the p
file is s27_37_57-v100r006sph005-bak.pat.
<Quidway> tftp 10.164.30.29 put s2700-v100r006c00.cc s2700
Info: Transfer file in binary mode.
Uploading the file to the remote TFTP server. Please wait...|
TFTP: Uploading the file successfully.
6472284 bytes send in 91 seconds.
<Quidway> tftp 10.164.30.29 put vrpcfg.zip vrpcfg-bak.zip
Info: Transfer file in binary mode.
Uploading the file to the remote TFTP server. Please wait.../
TFTP: Uploading the file successfully. 589 bytes send in 0.01 second.
<Quidway> tftp 10.164.30.29 put s
Info: Transfer file in binary mode.
TFTP: Uploading the file successfully.
333436 bytes send in 1 second.
Obtain the system software of the target version
Info: Transfer file in binary mode.
Downloading
6502764 bytes received in 63 seconds
downloaded.
(Optional) Obtain the new configuration file from the server.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
15
If the configuration file does not need to be changed after the upgrade, this step is not
gnew.zip
Info: Transfer file in binary mode.
TFTP: Downloading the file successfully.
5. system software in service, which is loaded when the S2700 is started.
<Qui
.cc
required.
<Quidway> tftp 10.164.30.29 get vrpcf
Downloading the file from the remote TFTP server. Please wait.../
2757 bytes received in 1 second.
Specify the
dway> startup system-software s2700-V100R006C00SPC800.cc
If the following information is displayed after you run the startup syste
Y to update the BootROM. If the BootROM is upgraded successfully, go
m-software file command, enter
to step 7; otherwise, go to step
6.
[N]: y
BOOTROM begin to be upgraded ! please wait for a moment
Info: BOOTROM UPGRADE OK
6. he S2700 is started.
uidway> system-view
otrom s2700-V100R006C00SPC800.cc
BOOTROM begin to upgraded ! please wait for a minute...
Info
Succ
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)
Succeeded in setting the software for booting system.
Upgrade the BootROM in service, which is loaded when t
<Q
[Quidway] upgrade basic-bo
Confirm basic BOOTROM will be upgrade?(Y/N)[N]: y
: BOOTROM UPGRADE OK
eeded in setting the software for booting system.
In the V100R005 and V100R006, the BootROM is upgraded automatically. To upgrade the software to
u must upgrade the BootROM manually. For details about automatic BootROM
upgrade, see Step 5. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure
7. Res
other versions, yo
tart the S2700.
ified or the invalid software is specified, the device will fail to
ystem software for next startup, see step 5.
fter the setting is
ion, please wait.
d to the configuration file for the next
:y
Now saving the current configuration to the slot 0.
ve the configuration successfully.
System will reboot! Continue?[Y/N]: y
Info: system is rebooting, please wait…
After the software is upgraded to V100R006C00SPC800, you must specify the system software for next
startup. If the system software is not spec
restart. For details about specifying the s
When the system asks you whether to save the configuration, enter y or n. A
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the configurat
Warning: All the configuration will be save
startup:flash:/vrpcfg.zip, Continue?[Y/N]
Info: Sa
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
16
----End
Method 2: Use the S2700 as the FTP Server
No FTP server software is installed on the S2700; therefore, the customer needs to buy FTP server
1. the S2700 as an FTP server.
0, and set the FTP user name to ftpuser and password to
ser service-type ftp
[Quidway-aaa] local-user ftpuser ftp-directory flash:
2.
d. This example assumes that ethernet/0/0/1 is used
ew
port link-type access
ernet 0/0/1
n10] quit
1.1 24
quit
3. Log
software and install it.
Configure
Start the FTP server on the S270
ftppwd.
<Quidway> system-view
[Quidway] ftp server enable
[Quidway] aaa
[Quidway-aaa] local-user ftpuser password simple ftppwd
[Quidway-aaa] local-user ftpu
[Quidway-aaa] return
Set an IP address for the S2700.
An idle service interface is recommende
and the IP address is 1.1.1.1/24.
<Quidway> system-vi
[Quidway]interface ethernet 0/0/1
[Quidway-Ethernet0/0/1]
[Quidway-Ethernet0/0/1]quit
[Quidway] vlan 10
[Quidway-vlan10] port eth
[Quidway-vla
[Quidway] interface vlanif 10
[Quidway-Vlanif10] ip address 1.1.
[Quidway-Vlanif10]
[Quidway]
in to the FTP server (the S2700).
Assume that the Windows XP operating system is used.
Store the file to be uploaded in the specified directory (for example, D:>directory). Choose
cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user
at the password prompt, and then press Enter. The following
o 1.1.1.1.
.
.1.1.1:(none)): ftpuser
Start > Run. Enter
prompt and the password
information is displayed:
D:>ftp 1.1.1.1
Connected t
220 FTP service ready
User (1
331 Password required for 1.
Password:
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
17
230 User logged in.
4. onfiguration file, and patch files.
ceived in 20.33Seconds 1350.65Kbytes/sec.
nsferred and you can find it
60Kbytes/sec.
n find it
226 Transfer complete.
ds 1333.74Kbytes/sec.
The preceding output indicates the configuration file has been transferred and you can find it
5. Upload the system software for the S2700.
0R006C00SPC800.CC.
226 Transfer complete.
6. (Optional) Upload the new configuration file to the S2700.
ot
required.
put vrpcfgnew.zip
7. Spe
<Quidway> startup system-software s2700-V100R006C00SPC800.cc
ftp>
Back up the system software, c
ftp> binary
200 Type set to I.
ftp> get s2700-v100r006c00.cc
200 Port command okay.
150 Opening BINARY mode data connection for s2700-v100r006c00.cc.
226 Transfer complete.
ftp: 6472284 bytes re
The preceding output indicates the configuration file has been tra
in D:>.
ftp> get vrpcfg.zip
200 Port command okay.
150 Opening BINARY mode data connection for vrpcfg.zip
226 Transfer complete.
ftp: 589 bytes received in 0.01Seconds
The preceding output indicates the configuration file has been transferred and you ca
in D:>.
ftp> get s27_37_57-v100r006sph005.pat
200 Port command okay.
150 Opening BINARY mode data connection for s27_37_57-v100r006sph005.pat.
ftp: 333436 bytes received in 0.25Secon
in D:>.
Run the put source-filename [ destination-filename ] command on the FTP client (PC) to
m the PC.upload the system software fro
ftp> put D:S2700-V100R006C00SPC800.cc
200 Port command okay.
150 Opening BINARY mode data connection for S2700-V10
ftp: 6502764 bytes in 47.10Seconds 140.76Kbytes/sec.
ftp>
If the configuration file does not need to be changed after the upgrade, this step is n
ftp>
cify the system software in service, which is loaded when the S2700 is started.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
18
is displayed after you run the startup system-software file command, enter
ly, go to step 9; otherwise, go to step
raded ! please wait for a moment
g system.
8. the BootROM in service, which is loaded when the S2700 is started.
upgrade basic-bootrom s2700-V100R006C00SPC800.cc
Warn
Upgr
[Slo
If the following information
Y to update the BootROM. If the BootROM is upgraded successful
8.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
BOOTROM begin to be upg
Info: BOOTROM UPGRADE OK
Succeeded in setting the software for bootin
(Optional) Upgrade
<Quidway> system-view
[Quidway]
ing: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
ading BOOTROM,please wait for a moment
t 0]:
Info: BOOTROM UPGRADE OK.
In the V
e
100R005 and V100R006, the BootROM is upgraded automatically. To upgrade the software to
9.
other v rsions, you must upgrade the BootROM manually. For details about automatic BootROM
upgrade, see Step 7. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure
Restart the S2700.
After the software is upgraded to V100R006C00SPC800, you must specify the system software for next
e device will fail to
guration, enter y or n. After the setting is
figuration, please wait.
All the configuration will be saved to the configuration file for the next
Now saving the current configuration to the slot 0.
Info: Save the configuration successfully.
y
it…
Method 3: Use the S2700 as the FTP Client
startup. If the system software is not specified or the invalid software is specified, th
restart. For details about specifying the system software for next startup, see step 7.
When the system asks you whether to save the confi
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the con
Warning:
startup:flash:/vrpcfg.zip, Continue?[Y/N]:y
System will reboot! Continue?[Y/N]:
Info: system is rebooting, please wa
----End
No FTP client software is installed on the S2700; therefore, the customer needs to buy FTP client
software and install it.
1. Configure the PC as the FTP server.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
19
Run an FTP server program on the PC, for example, wftpd32. Choose
Users/rights.
Security >
Click New User to set the user name and password. Here, the user name is S2700 and the
tory text box. Here, the
root directory is D:ftp. Click Done to close the dialog box.
Do not stop the FTP server program when you are backing up data.
2.
he S2700 are the same as the FTP commands in the DOS system.
server is 10.164.30.27, the FTP user name is S2700,
user is 123456.
Enter the user name and press Enter.
ease
: # Enter the password 123456 and press Enter. The password displayed
xt.
r and specify the name
password is 123456. Enter the FTP root directory in the Home Direc
Back up the system software, configuration file, and patch files.
The FTP commands on t
Assume that the IP address of the FTP
and the password of the FTP
<Quidway> cd flash:/
<Quidway> ftp 10.164.30.27
Trying 10.164.30.27 ...
Press CTRL+K to abort
Connected to 10.164.30.27.
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User(10.164.30.27:(none)):S2700 #
331 Give me your password, pl
Enter password
on the screen is in cipher te
230 Logged in successfully
[ftp] binary
200 Type is Image (Binary)
Back up the system software s2700-v100r006c00.cc to the FTP serve
of the backup file as s2700-v100r006c00-bak.cc. If the name of the backup file is not
specified, the original name is used.
[ftp] put s2700-v100r006c00.cc s2700-v100r006c00-bak.cc
200 PORT command successful
150 Opening BINARY mode data connection for file transfer
226 Transfer complete.
FTP: 6472284 byte(s) sent in 41.176 second(s) 1296.55Kbyte(s)/sec.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
20
Back up the configuration file vrpcfg.zip to the FTP server and specify the name of the
backup file as vrpcfg-bak.zip. If the name of the backup file is not specified, the original
[ftp] put vrpcfg.zip vrpcfg-bak.zip
FTP: 1387 byte(s) sent in 0.176 second(s) 22.04Kbyte(s)/sec.
cify the
.pat
200 PORT command okay
" file ready to receive in IMAGE / Binary
mode
FTP: 333436 byte(s) sent in 0.322 second(s) 1035.51Kbyte(s)/sec.
3.
file transfer
226 Transfer complete.
econd(s) 1117.40Kbyte(s)/sec.
You can specify the filename of the upgrade program. If the filename is not specified, the
4. onfiguration file.
s not need to be changed after the upgrade, this step is not
221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye
6. Spe
<Quidway> startup system-software s2700-V100R006C00SPC800.cc
name is used.
200 PORT command successful
150 Opening BINARY mode data connection for file transfer
226 Transfer complete.
Back up the patch file s27_37_57-v100r006sph005.pat to the FTP server and spe
name of the backup file as s27_37_57-v100r006sph005bak.pat. If the name of the backup
file is not specified, the original name is used.
[ftp] put s27_37_57-v100r006sph005.pat s27_37_57-v100r006sph005bak
150 "D:ftp s27_37_57-v100r006sph005bak.pat
226 Transfer finished successfully.
Obtain the system software of the target version.
[ftp] get S2700- V100R006C00SPC800.cc
200 PORT command successful
150 Opening BINARY mode data connection for
FTP: 6502764 byte(s) received in 54.500 s
original name is used.
(Optional) Obtain the new c
If the configuration file doe
required.
[ftp] get vrpcfgnew.zip
5. Close the FTP connection.
[ftp] bye
cify the system software in service, which is loaded when the S2700 is started.
If the following information is displayed after you run the startup system-software file command, enter
Y to update the BootROM. If the BootROM is upgraded successfully, go to step 8; otherwise, go to step
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
7.
BOOTROM begin to be upgraded ! please wait for a moment
Info: BOOTROM UPGRADE OK
Succeeded in setting the software for booting system.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
21
7. h is loaded when the S2700 is started.
trom s2700-V100R006C00SPC800.cc
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
Upgrading BOOTROM,please wait for a moment
[Slo
Info
(Optional) Upgrade the BootROM in service, whic
<Quidway> system-view
[Quidway] upgrade basic-boo
t 0]:
: BOOTROM UPGRADE OK.
and V100R006, the BootROM is upgraded automatically. To upgrade the software to
other versions, you must upgrade the BootROM manually. For details about automatic BootROM
tep 6. In the case of a version rollback, you are advised to manually upgrade the
BootROM to prevent a rollback failure.
8. Res
In the V100R005
upgrade, see S
tart the S2700.
NOTE
After the software is upgraded to V100R006C00SPC800, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
about specifying the system software for next startup, see step 6.
guration, please wait.
ved to the configuration file for the next
startup:flash:/vrpcfg.zip, Continue?[Y/N]:y
ng the current configuration to the slot 0.
Info: Save the configuration successfully.
System will reboot! Continue?[Y/N]: y
Info: system is rebooting, please wait…
4.2 Upgrad
Using the
If the BootROM method is used, the services will be interrupted for a long time; therefore,
you are advised to upgrade an operating device by using the command line. If the device
cannot enter the command line mode, upgrade the device by using the BootROM.
restart. For details
When the system asks you whether to save the configuration, enter y or n. After the setting is
complete, enter y to restart the system.
<Quidway> reboot
Info: The system is now comparing the confi
Warning: All the configuration will be sa
Now savi
----End
ing the Switch to the V100R006C00SPC800
BootROM
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
22
Figure 4-1 Flowchart for upgrading the version to the V100R006C00SPC800 using the
BootROM
End
Start
Upgrade BootROM See 4.2.1
Upload system
software
See 4.2.2
Specify startup
software
See 4.2.3
Restart the switch See 4.2.4
The methods for upgrading the system software using the BootROM are similar on the S2700, S3700,
S5700 and the S6700. Here, the method for upgrading the system software on the S2700 is taken as an
example.
4.2.1 Upgrading the BootROM
Purpose To upgrade the BootROM
Services are interrupted during the upgrade and the device reboot.Impact
The upgrade takes about 100 seconds when the transmission rate of the
serial interface is 115200 bit/s.
Time
Required
After backing up the key data in the flash memory, you must run the
reboot command in the user view to restart the system.
Prerequisites
Do not restart or power off the S2700 when the information "Update BOOTROM system…"
is being displayed during the upgrade of the BootROM. Otherwise, the S2700 runs
abnormally. In this case, contact Huawei technical personnel.
You can restart or power off the S2700 only when the message "done!" is displayed.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
23
The BootROM menu varies according to the version. Here, the BootROM of
V100R006C00SPC800 is taken as an example.
1. Use a serial cable to connect the serial interfaces on the PC and the S2700 and start the
HyperTerminal on the PC.
2. Enter the connection name and click OK.
3. Select the serial interface and click OK.
4. On the COM Properties page, click Restore Defaults. Then set the value of Bits per second
to 9600 and click OK.
5. If the prompt is displayed on the HyperTerminal, the HyperTerminal is connected to the
S2700. In this case, you can upgrade the S2700 using the BootROM.
6. Enter the BootROM menu.
Before entering the BootROM menu, you need to restart the S2700. During the restart of the
S2700, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1
Press Ctrl+B before the countdown timer expires, and then enter the password. The default
password is huawei or www.huawei.com. Then the advanced BootROM menu is displayed.
The following information is displayed:
BOOTROM MENU
1. Boot with default mode
2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Reboot
Enter your choice(1-7):
7. Enter the BootROM submenu.
Select 2. Enter serial submenu. The following information is displayed:
SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu
8. Modify the parameters of the serial interface.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
24
Changing the transmission rate of the serial interface causes interruption of the
communication between the PC and S2700. To restore the communication between the PC
and the S2700, you must set the transmission rate of the serial interface on the PC the same as
that of the serial interface on the S2700.
Select 3. Modify serial interface parameter. The following information is displayed:
Enter your choice(1-5): 3
1: 9600(default)
2: 19200
3: 38400
4: 57600
5: 115200
please select an appropriate baudrate:
Enter your choice(1-5):
Select the transmission rate for the serial interface as required. The transmission rate is
expressed in bit/s. The default transmission rate of the serial interface on the S2700 is 9600
bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It
is recommended that you enter 5: 115200.
If you change the transmission rate of the serial interface on the S2700, set the transmission
rate of the serial interface on the PC the same as that of the serial interface on the S2700. In
this manner, you can restore the communication between the PC and the S2700.
For example, after you select 5: 115200, the following information is displayed:
BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps
In this case, you need to perform the following settings on the HyperTerminal of the PC to
restore the communication between the PC and the S2700:
On the HyperTerminal, choose Call > Disconnect. The connection is closed
Choose File > Properties. The Properties dialog box is displayed.
On the Connect To tab page, click Configure. The COM Properties dialog box is
displayed.
In the Bits per second drop-down list, select 115200.
In the COM Properties and Properties dialog boxes, click OK.
On the HyperTerminal, choose Call > Call. Press Enter. The connection is
reestablished.
9. Upgrade the BootROM.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
25
The BootROMs for products of various series are incompatible with each other. For example,
the BootROM of the S2700 cannot be used to upgrade the BootROM of the S3700; the
BootROM of the S3700 cannot be used to upgrade the BootROM of the S2700.
Select 1. Update BootROM system. The following information is displayed:
Enter your choice(1-4): 1
Please Select File.
XMODEM downloading ...CC
Choose Transfer > Send File. The Send File dialog box is displayed.
Click Browse. Then select the bootrom128.bin file for upgrading the BootROM.
Ensure that the selected BootROM file corresponds to the product.
Select XMODEM from the Protocol drop-down list box. Click Send to start sending the file.
After the upgrade file is transferred, the following information is displayed:
XMODEM downloading ...CC download to SDRAM successfully
Warning: Don't Power-off or Reset the Device!!!
Update bootrom system ... done !
Then, the S2700 automatically upgrades the BootROM by using the upgrade file. After the
upgrade, the S2700 automatically returns to the BootROM menu.
10. After the BootROM is upgraded, restore the default rates of the serial interface and the
HyperTerminal, and then reestablish the connection.
Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and
then select 7. Reboot to reboot the BootROM.
----End
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
26
4.2.2 Uploading the System Software
Uploading the System Software Through the Serial Interface
Purpose To upgrade the system software
Services are interrupted during the system software uploading and the
device reboot.
Impact
The software uploading time depends on many factors, such as the
system software size, transmission rate on the serial interface, and
operator's skill. When the transmission rate of the serial interface is
115200 bit/s, the uploading time is about 30 minutes.
Time Required
Prerequisites The matched BootROM is upgraded.
The flash memory has enough space to store the system software.
1. Enter the BootROM menu.
When the S2700 is starting, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1
Press Ctrl+B before the countdown timer expires, and then enter the password. The default
password is huawei. Then the advanced BootROM menu is displayed. The following
information is displayed:
BOOTROM MENU
1. Boot with default mode
2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Reboot
Enter your choice(1-7):
2. Select 2. Enter serial submenu. The following information is displayed:
SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu
Enter your choice(1-4):
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
27
3. Modify the parameters of the serial interface.
Changing the transmission rate of the serial interface causes interruption of the
communication between the PC and S2700. To restore the communication between the PC
and the S2700, you must set the transmission rate of the serial interface on the PC the same as
that of the serial interface on the S2700.
Select 3. Modify serial interface boot parameter. The following information is displayed:
1: 9600(default)
2: 19200
3: 38400
4: 57600
5: 115200
please select an appropriate baudrate:
Enter your choice(1-5):
Select the transmission rate for the serial interface as required. The transmission rate is
expressed in bit/s. The default transmission rate of the serial interface on the S2700 is 9600
bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It
is recommended that you enter 5. 115200. If you change the transmission rate of the serial
interface on the S2700, set the transmission rate of the serial interface on the PC the same as
that of the serial interface on the S2700. In this manner, you can restore the communication
between the PC and the S2700.
For example, after you select 5: 115200, the following information is displayed:
BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps
In this case, you need to perform the following settings on the HyperTerminal of the PC to
restore the communication between the PC and the S2700:
On the HyperTerminal, choose Call > Disconnect. The connection is closed
Choose File > Properties. The Properties dialog box is displayed.
On the Connect To tab page, click Configure. The COM Properties dialog box is
displayed.
Select 115200bit/s from the Bits per second drop-down list box.
In the COM Properties and Properties dialog boxes, click OK.
On the HyperTerminal, choose Call > Call. The connection is reestablished.
4. Upgrade the system software.
Select 2. Download file to Flash through serial interface in the serial interface submenu,
and the following information is displayed:
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
28
Enter your choice(1-4): 2
Please Select File.
XMODEM downloading ...CC
Choose Transfer > Send File. The Send File dialog box is displayed.
Click Browse to select the upgrade file of the system software. Then select Xmodem from the
Protocol drop-down list box. Click Send to start sending the file.
After transferring the upgrade file, the system prompts you whether to change the file name. If
no, save it with the default file name. The default file name is not the uploaded file name. The
system software name in the flash memory or the default file name hw-switch.cc is used.
Generally, it is recommended that the file name be changed.
Only the files with the file name extension .cc can be used as the upgrade files of the system software on
the S2700.
If you need to name the upgrade file S2700-V100R006C00SPC800.CC, the following
information is displayed:
XMODEM downloading ...CC download successfully!
Do you like to save it named " S2700-V100R006C00SPC800.CC"?
If you like then press return key, otherwise give a new name for saving it:
S2700-V100R006C00SPC800.CC
If the file S2700-V100R006C00SPC800.CC has already been saved in the flash memory, the
system prompts you whether to overwrite the existing file with the new one. The following
information is displayed:
flash:/S2700-V100R006C00SPC800.CC already exist,
delete it?(Y/N):y
Deleting file.......................................done
took time : 251s
Writing
Flash.............................................................................
..................................................................................
..............done
file length: 6502764 bytes, took time : 144s
SERIAL SUBMENU
1. Update BOOTROM system
2. Download file to Flash through serial interface
3. Modify serial interface parameter
4. Return to main menu
Enter your choice(1-4):
After the upgrade file is transferred, select 4. Return to main menu to return to the
BootROM menu.
----End
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
29
Uploading the System Software Through the Network Port
Purpose To upload the system software
Services are interrupted during the system software uploading and the
device reboot.
Impact
If the system software is uploaded through the FTP or TFTP protocol,
the system software uploading time is about one minute.
Time
Required
Prerequisites The matched BootROM is upgraded.
The flash memory has enough space to store the system software.
The FTP service is enabled on the PC.
Pay attention to the following points:
Select 4. Return to main menu in the BootROM menu to return to the BootROM menu,
and then select 7. Reboot to reboot the BootROM. Enter the BootROM menu and load
the system software. In addition, specify the software to be loaded in the startup.
Upgrade the system software using the network interface in the BootROM menu.
1. Enter the BootROM menu.
Before entering the BootROM menu, you need to restart the S2700. During the restart of the
S2700, the following information is displayed:
Press Ctrl+B to enter BOOTROM menu... 1
Press Ctrl+B before the countdown timer expires, and then enter the password. The default
password is huawei. Then the advanced BootROM menu is displayed. The following
information is displayed:
BOOTROM MENU
1. Boot with default mode
2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
6. Modify BOOTROM password
7. Reboot
Enter your choice(1-7):
2. Select 4. Enter serial submenu. The following information is displayed:
ETHERNET SUBMENU
1. Download file to SDRAM through ethernet interface and boot
2. Download file to Flash through ethernet interface
3. Modify ethernet interface boot parameter
4. Return to main menu
Enter your choice(1-4):
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
30
3. Modify the parameters of the network interface.
Select 3. Modify ethernet interface boot parameter. The following information is
displayed:
BOOTLINE SUBMENU
1. Set TFTP protocol parameters
2. Set FTP protocol parameters
3. Return to ethernet menu
Select TFTP or FTP as required.
For example, the following information is displayed if you select 2. Set FTP protocol
parameters. The displayed information cannot be cleared. New settings will overwrite the
old settings.
If the TFTP protocol is used, you do not need to enter the user name and password.
'.' = clear field; '-' = go to previous field; ^D = quit
Load File name : S2700-V100R006C00SPC800.CC
Switch IP address : 192.168.1.15:FFFFFF00
Server IP address : 192.168.1.40
FTP User Name : cx
FTP User Password : cx
The fields are described as follows:
Load File name: file name of the startup file to be loaded
Switch IP address: device IP address (the mask is optional)
Server IP address: server IP address
FTP User Name: FTP user name
FTP User Password: FTP password
4. Download the system software.
After network interface parameters are modified, select 3. Return to ethernet menu to return
to the Ethernet submenu. Connect the data line to port 1 on the S2700 panel (or connect the
data line to the MEth interface of the S5700), and then select 2. Download file to Flash
through ethernet interface to load the file. The following information is displayed:
'.' = clear field; '-' = go to previous field; ^D = quit
boot device : et
unit number : 0
processor number : 0
host name : host
file name : S2700-V100R006C00SPC800.CC
inet on ethernet (e) : 192.168.1.15:FFFFFF00
host inet (h) : 192.168.1.40
user (u) : cx
ftp password (pw) : cx
flags (f) : 0x0
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
31
Attached TCP/IP interface to mottsec0.
Attaching network interface lo0... done.
Loading...
Read file to sdram .......Done
Writing
Flash.............................................................................
..................done
File length: 6502764 bytes
Took time : 33s
After the upgrade file is transferred, select 4. Return to main menu to return to the
BootROM menu.
----End
4.2.3 Specifying the System Software to Be Loaded for Starting
the Switch
Purpose To specify the system software for next startup
Services are interrupted when you are specifying the system software and
the device is restarting.
Impact
The system software to be specified has been downloaded to the flash
memory.
Prerequisite
1. Specify the system software to be loaded for starting the switch.
After returning to the BootROM menu, select 3. Enter startup submenu to enter the startup
submenu. The following information is displayed:
Startup Configuration Submenu
1. Display startup configuration
2. Modify startup configuration
3. Return to main menu
Enter your choice(1-3):
2. Select 2. Modify startup configuration to set the startup mode of the S2700, system
software, configuration file, license file, and patch file. The following information is
displayed:
Note: startup file field cannot be cleared
'.'=clear field; '^D'=quit; Enter=use current configuration
startup type(1: Flash 2: Server)
current: 1
new : 1
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
32
Flash startup file (cannot be cleared)
current:
new : S2700-V100R006C00SPC800.CC
saved-configuration file
current: vrpcfg.zip
new :
license file
current:
new :
patch package
current:
new :
Table 4-1 describes the displayed information.
Table 4-1 Description of the displayed information
Field Description
startup type Startup mode:
1: loads the system software from the flash memory.
2: loads the system software from the server.
Flash startup file System software loaded during the startup. If the system
software is loaded from the server, you do not need to set the
field.
saved-configuration file Configuration file loaded during startup.
patch package Patch file loaded during startup.
current File that is currently loaded.
new File to be loaded during the next startup.
Startup Configuration Submenu
1. Display startup configuration
2. Modify startup configuration
3. Return to main menu
Enter your choice(1-3):
3. After entering the startup information, select 3. Return to main menu to return to the
BootROM menu.
BOOTROM MENU
1. Boot with default mode
2. Enter serial submenu
3. Enter startup submenu
4. Enter ethernet submenu
5. Enter filesystem submenu
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
33
6. Modify BOOTROM password
7. Reboot
Enter your choice(1-7):
----End
4.2.4 Restarting the Switch
The switch is automatically upgraded by loading the latest system software during startup.
Enter 7. Reboot on the advanced BootROM menu to restart the switch. Then, the S2700
restores the baud rate on the console interface to 9600 bit/s. The baud rate of the
HyperTerminal also needs to be set to 9600 bit/s. The PC then can communicate with the
S2700.
4.3 Upgrading the S5700-SI to V100R006C00SPC800 Using
the USB Flash Drive
4.3.1 Overview
If you do not have a PC in the on-site deployment, use the USB flash drive in which the
system software and configuration file are stored. The software commissioning engineer is not
required.
Only the S5700-SI and S6700 can be upgraded using the USB flash drive. Stacks do not support this
upgrade method.
The general process of the upgrade in the USB way is as follows:
a. Copy files.
When the S5700-SI is started successfully (the SYS indicator is in green and blinks at
0.5 Hz), the USB flash drive can be inserted to load files. The S5700-SI automatically
downloads the system software and configuration file according to the index file in the
USB flash drive.
b. Restart the switch.
The S5700-SI sets the system software and configuration file for next startup, and then
restarts automatically.
c. Verify the loading of files.
After restarting successfully (the SYS indicator is in green and blinks at 0.5 Hz), the
S5700-SI begins to verify the loaded files. When the SYS indicator is in orange and
blinks at 0.5 Hz, the upgrade is finished.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
34
4.3.2 Upgrading the Software Using the USB Flash Drive
Preparations for Upgrade
1. Prepare the hardware.
USB port: The S5700-SI provide USB 1.1; the S6700 provide USB 2.0.
USB flash drive:
The USB flash drive delivered with Huawei switch is recommended because this USB
flash drive is compatible with the switch. The USB flash drive must be paid
independently. If you have not bought the USB flash drive, contact local Huawei office.
The USB flash drive must use the FAT32 format; otherwise, set the format to FAT32
before using it.
The space in the USB flash drive must be sufficient for the system software and
configuration file.
2. Prepare system software, configuration file, web file, and patch file.
3. Create the index file.
a. Create the file usbload_config.txt.
b. Fill in the file.
If you need to upgrade the system software, configuration file or patch file of V100R006, the
index file is in any of the following formats:
<sn=201105091219;/>
<mac=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>
<esn=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>
<boardtype=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>
The first line in the index file must be the SN to prevent repeated copy. The SN consists of creation
date + time, for example, <sn=201105091219;/>. Before copying a file, the device compares the SNs.
If the SN of a file to be copied already exists, the device does not copy the file. After the file is
copied, the device stores the SN. The index files without SNs are considered invalid, and the device
will stop copying the files.
If an index file contains the following three formats, the device uses the information in format (2). If
the required information is not obtained, the device uses the information in format (3) and then
format (1). When only one USB flash drive is used in the upgrade, the values of mac=, esn=, and
boardtype= are default. When the device obtains the value default, the device starts to copy the file
without comparing it with other files.
When editing an index file, press Enter when a line is finished. After editing the file, save it.
Select the upgrade files, including system software, configuration file, Web file, and patch file as
required.
The upgrade procedures for S5700-SI, and S6700 are the same.
(1) To upgrade the same system software, configuration file, Web file, and patch file on
multiple devices, fill in the file in the format <boardtype=; vrpfile=; vrpver=; cfgfile=;
webfile=; patchfile=;/>.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
35
− To obtain the value of boardtype, view device labels or run the display version
command. boardtype=default indicates that all devices will be upgraded.
− Fill in the system software name behind vrpfile=.
− Fill in the version number behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the web file name behind webfile=.
− Fill in the patch file name behind patchfile=.
The following are the index files of different devices:
<boardtype=S5728C-SI; vrpfile=S5700SI-V100R006C00SPC800.CC;
vrpver=V100R006C00SPC800; cfgfile=; webfile=; patchfile=;/>
<boardtype=S6748-EI; vrpfile=S6700-V100R006C00SPC800.CC; vrpver=V100R006C00SPC800;
cfgfile=; webfile=; patchfile=;/>
The following two formats are used for upgrading a single device:
(2) <mac=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>
− View the device's MAC address on the chassis and fill in the MAC address behind
mac= in the format XXXX-XXXX-XXXX.
− Fill in the system software name behind vrpfile=.
− Fill in the version number behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the web file name behind webfile=.
− Fill in the patch file name behind patchfile=.
The following is an example of configuration file:
<mac=0018-8200-0001; vrpfile=; vrpver=; cfgfile=vrpcfg.cfg; webfile=; patchfile=;/>
The following is an example of patch file:
<mac=0018-8200-0002; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=patch.pat;/>
(3) <esn=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>
− View the device's ESN and fill in the ESN behind esn=.
− Fill in the system software name behind vrpfile=.
− Fill in the version number behind vrpfile=.
− Fill in the configuration file name behind cfgfile=.
− Fill in the web file name behind webfile=.
− Fill in the patch file name behind patchfile=.
The following is an example of patch file:
<esn=020TEA10A9000016; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=patch.pat;/>
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
36
The following is an example of system software:
<esn=020TEA10A9000017; vrpfile=S5700SI-V100R006C00SPC800.CC;
vrpver=V100R006C00SPC800; cfgfile=vrpcfg.cfg; webfile=; patchfile=;/>
If a keyword is not found or matched, the value of this item is considered to be empty.
If the version number behind vrpver= is the same as the current version, the device will not
restart.
4. Copy the index file, system software, configuration file, Web file, and patch file to the root
directory of the USB flash drive.
The index files must be stored to the root directory on the USB flash drive; the other files are stored in
the corresponding directories.
Do not power off the switch during file copy; otherwise, the upgrade fails or the switch
cannot start.
Do not remove the USB flash drive before the upgrade is finished; otherwise, the USB
flash drive may be damaged.
Procedure
1. Power on the S5700-SI, and wait until the system completes the startup (you are advertised to
wait for two minutes).
2. Confirm that the system is operating stably (the SYS indicator is in green and blinks every
two seconds). If the system operating is unstable, wait or solve the issue.
If the SYS indicator is on and in green or orange, the system startup is not finished. Wait
until the system starts successfully.
If the SYS indicator is on and in red, the system is started but an error occurs. Fix the
problem before the next step. Check whether the power supply and the fan function
properly. If no, power off the S5700-SI, and then restart the S5700-SI. If the fault persists
(the indicator is on and in red), contact Huawei technical support personnel.
3. Insert the USB flash drive.
If the SYS indicator is in green and blinks more than twice every second, the system is
copying the system software and configuration file from the USB flash drive.
After copying the files, the system restarts.
If the SYS indicator is in orange and blinks every two seconds after the restart, the
upgrade is successful. Now you can remove the USB flash drive.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 4 Upgrade Operations on a Single Switch
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
37
If the SYS indicator is on or blinks in red, or blinks and is in read, an error occurs. Power off
the S5700-SI and power on it, and then insert the USB flash drive again. If the upgrade fails
three times, check whether the index file on the USB flash drive is correct, or contact the
Huawei technical support personnel.
NOTE
When using the USB flash drive for upgrade, change the SN in the USB flash drive.
----End
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
38
5 Upgrade Operations on a Stack
5.1 Upgrading All Stack Member Switches to
V100R006C00SPC800 by Using the Command Line
To upgrade the system softwarePurpose
Services are interrupted when the devices restart.Impact
When a single device is upgraded and service deployment is simple,
stack is upgraded, theservices are interrupted about 3 minutes. When a
Time
Required
service interruption time increases, and the time depends on the
complexity of services and the stack.
Prerequisites The devices to be upgraded function properly.
The flash memory has enough space to store the system software.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
39
The methods of for upgrading the system software of the S3700, S5700 and the S6700 using the
command line interface are similar. Here, the S3700 is used as an example.
the system software by using the S3700 as the FTP
server. For other methods of loading the system software, see the Quidway S3700/S5700/S6700
ns.
retain the roles of the master and slave devices after the upgrade, set priority of the master switch
The section describes only how to download
Series Ethernet Switches Configuration Guide - Basic Configuratio
The S5700/S6700 provides a management interface MEth. You can use this interface as a Layer 3
interface.
To
to be the highest in the stack before the upgrade.
When an S3700 is upgraded to V100R006C00SPC800, you must delete the startup file
because the flash memory space is limited.
The following operations are performed on the master switch. Here, the stack contains two
1.
te /unreserved flash:/S3752-V100R006C00.cc
tware. If you delete it, there is no software to
e the file? [Y/N]:y
Warning: The contents of file flash:/S3752-V100R006C00.cc cannot be recycled. Continue?
eting file flash:/S3752-V100R006C00.cc...
Deleting file permanently from flash will take a long time if
...........................................................
.....................................................
.......................................succeeded.
0R006C00.cc
e it, there is no software to
nfirm to delete the file? [Y/N]:y
flash:/S3752-V100R006C00.cc cannot be recycled.
2. as the FTP server.
and set the FTP user name to ftpuser and password to
tp server enable
member switches.
Delete the current startup software package.
<Quidway> dele
Info:This is Next startup system sof
reboot successfully!Confirm to delet
[Y/N]:y
Info: Del
needed.................
.............................
...............
<Quidway> delete /unreserved slot1#flash:/S3752-V10
Info:This is Next startup system software. If you delet
reboot successfully!Co
Warning: The contents of file slot1#
Continue? [Y/N]:y
Info: Deleting file slot1#flash:/S3752-V100R006C00.cc...
Deleting file permanently from flash will take a long time if
needed............................................................................
..................................................................................
..................................................................................
..succeeded.
Configure the switch
Start the FTP service on the switch,
ftppwd.
<Quidway> system-view
[Quidway] f
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
40
[Quidway] aaa
[Quidway-aaa] local-user ftpuser password simple ftppwd
local-user ftpuser service-type ftp
[Qui flash:
[Quidway-aaa] return
3.
n an idle interface. Here, ethernet 0/0/1 is used as an example.
view
rnet 0/0/1
an10] port ethernet 0/0/1
y] interface vlanif 10
[Quidway]
4.
[Quidway-aaa]
dway-aaa] local-user ftpuser ftp-directory
Configure an IP address for the switch.
Configure the IP address o
<Quidway> system-
[Quidway]interface Ethe
[Quidway-Ethernet0/0/1]port link-type access
[Quidway-Ethernet0/0/1]quit
[Quidway] vlan 10
[Quidway-vl
[Quidway-vlan10] quit
[Quidwa
[Quidway-Vlanif10] ip address 1.1.1.1 24
[Quidway-Vlanif10] quit
Log in to the FTP server (the switch).
Assume that the Windows XP operating system is used.
. Choose
d press Enter. Enter FTP 1.1.1.1. Enter the user name at the user
nter. The following
n is displayed:
>ftp 1.1.1.1
ted to 1.1.1.1.
220 FTP service ready.
331 Password required for 1.
230 User logged in.
ftp>
5. Uploa the switch.
the FTP client to upload
m software is uploaded to the switch, run the bye command to
2-V100R006C00SPC800.CC
-V100R006C00SPC800.CC.
s sent in 60.40Seconds 140.76Kbytes/sec.
ftp> bye
221 Server closing.
D:>
Store the file to be uploaded in the specified directory (for example, D:>directory)
Start > Run. Enter cmd an
prompt and the password at the password prompt, and then press E
informatio
D:
Connec
User (1.1.1.2:(none)): ftpuser
Password:
d the system software to
Run the put source-filename [ destination-filename ] command on
the system software. After syste
close the FTP connection and return to the user view.
ftp> put D:S375
200 Port command okay.
150 Opening BINARY mode data connection for S3752
226 Transfer complete.
ftp: 8742812 byte
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
41
6. Specify th uploaded software as the next startup software.
<Qui
e
dway> startup system-software S3752-V100R006C00SPC800.CC all
If the following information is displayed after you run the startup system-software file command, enter
y to upgrade the BootROM.
Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y
e upgraded ! please wait for a moment
ooting system on 0.
C800.cc to
booting system on 1.
7.
BOOTROM begin to b
Info: BOOTROM UPGRADE OK
Info: Succeeded in setting the software for b
100% complete
Info: Copied file flash:/S3752-V100R006C00SP
slot1#flash:/S3752-V100R006C00SPC800.cc...Done.
Info: Succeeded in setting the software for
Restart the switch.
After the software is upgraded to V100R006C00SPC800, you must specify the system software for next
startup. If the system software is not specified or the invalid software is specified, the device will fail to
restart. For details about specifying the system software for next startup, see step 5.
When the system asks you whether to save the configuration, enter y or n. After the setting is
Info: The system is now comparing the configuration, please wait.
g: All the configuration will be saved to the configuration file for the next
p:flash:/vrpcfg.zip, Continue?[Y/N]:y
Now saving the current configuration to the slot 0.
Info: Save the configuration successfully.
----E
5.2 Using the Intelligent Upgrade Function
5.2.1 Overview
el rades or rolls back the system software
of a new itch.
complete, enter y to restart the system.
<Quidway> reboot
Warnin
startu
Info: Save the configuration successfully.
Now saving the current configuration to the slot 1.
System will reboot! Continue?[Y/N]: y
Info: system is rebooting, please wait…
nd
Int ligent upgrade is a function that automatically upg
member switch to the version of the master sw
A stack system is established only when all the following requirements are met:
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
42
All the member switches use the same software version. If the master switch detec
different software version on the new member switch, it upgrades or rolls back the
software of
ts a
the new member switch to the version of the stack.
ports a maximum of eight switches in a stack system. The other S3700 models and the
up to nine switches in a stack system.
s
ing function is enabled on all the member switches.
he stack processes version upgrade and rollback for new member switches in the same way.
5.2.2 Upgrading a N ber Switch Using the Intelligent
Upgrade Function
Preparations for
Be
nnected to other member switches by using stack cables
bled by
The S3752 sup
S5700 support
The S3752 and S3728 cannot be added to the same stack system.
All the member switches belong to the same series. That is, the EI series and SI serie
cannot form a stack.
All the member switches are connected by using stack cables and stack modules.
All the member switches are working properly.
The stack
T
ew Mem
Upgrade
fore upgrading a new member switch of a stack, ensure that:
The new member switch and the current stack members belong to the same series.
The new member switch is co
and stack modules.
The stacking function is enabled on the new member switch. (This function is ena
default.)
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
43
If the flash memory of the new member switch does not have sufficient space to store the
startup software package, the switch automatically deletes a software package to free up
tch is an S5700, it deletes a non-startup software package. If the switch
is an S3700, it deletes the current startup software package. If the available space in the
switch restarts repeatedly. In
this case, upgrade the software of the switch to the version of the stack system manually,
re, see chapter 4 Upgrade
itch.
During the upgrade, ensure that the stack cables are functioning properly. If the upgrade of
the space. If the swi
flash memory is still insufficient for the upgrade software, the
and then add the switch to the stack. For the upgrade procedu
Operations on a Single Sw
a switch fails, upgrade the system software of the switch to the version of the stack
manually, and then add the switch to the stack.
Upgrade Process
On the master switch:
In Stack, device 0 load to new device 1 .......... start
In Stack, device 0 load to new device 1 .......... success
On the new member switch:
The Software Version is Low.Version is V100R006C00!
100% completed
In Stack, device 0 load flash:/S5700EI-V100R006C00SPC800.CC to new device 1(self) ...
Success
Starting upgrade BOOTROM .............. Pass
Device starting reset.
If the flash memory of the new member switch does not have sufficient space for the upgrade
software, the following information is displayed:
On the master switch:
In Stack, device 0 load to new device 1 .......... start
In Stack, device 0 load to new device 1 .......... fail
On the new member switch:
In Stack, upgrading from slot 4 to slot 0(self) .......... start
Info: Free space is not enough. Auto deleting <flash:/S3728-V100R006C00.cc> file ....
Start the new member switch.
The master switch of the stack automatically upgrades the new switch. If the upgrade is
successful, the following information will be displayed:
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 5 Upgrade Operations on a Stack
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
44
................................................................................
........................... success
100% completed
In Stack, device 4 load to new device 0 (self) ... Success
Upgrading BOOTROM .............. Pass
Manually upgrade the system softw
then add the switch to the stack syst
V100R006C00SPC800 Using the Co
V100R006C00SPC800 Using the BootROM.
are of the switch to the version of the stack system, and
em. For details, see sections 4.1 Upgrading the Switch to
mmand Line or 4.2 Upgrading the Switch to the
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 6 Verifying the Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
45
6 Verifying the Upgrade
6.1 Verification Checklist
Table 6-1 Verification checklist
No. Item Criteria Result
1 Check the current system The system software version
software version is V100R006C00SPC800.
2 Check the device running The device runs properly.
status
3 Check the system The system configuration is
configuration correct.
6.2 Checking the Current System Software Version
nning on the
s
4M bytes DDR Memory
Pcb Version : VER C
Basic BOOTROM Version : 124 Compiled at Apr 20 2011, 10:04:52
Run the display version command to view the version of the system software ru
S2700.
<Quidway> display version
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.70 (S2700 V100R006C00SPC800)
Copyright (C) 2003-2011 HUAWEI TECH CO., LTD
Quidway S2718TP-SI Routing Switch uptime is 0 week, 0 day, 0 hour, 4 minute
EDFE 0(Master) : uptime is 0 week, 0 day, 0 hour, 4 minutes
6
16M bytes FLASH
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 6 Verifying the Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
46
Software Version : VRP (R) Software, Version 5.70 (S2700 V100R006C00SPC800)
6.3 Checking the Device Running Status
Run the display device command to check the s
the device functions properly.
<Quidway> display device
S2718TP-SI's Device status:
Slot Sub Type Online Power Register Status Role
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0 - 2718F Present PowerOn Registered Normal Master
6.4 Checking the System Configuration
Use the display current-configuration command to check the system configuration. Check
V100R006C00SPC800 (V100R006C00SPC800 is
n number depends on the released version) and
e following configuration is taken as an example).
d after the upgrade. For the command line changes, see
the release notes of the matching version.
authorization-scheme default
ccounting-scheme default
omain default
domain default_admin
local-user admin password simple admin
local-user admin service-type http
#
witch running status. Normal indicates that
whether the system software version is
taken as an example and the actual versio
whether the configuration is restored (th
The configuration file may be modifie
<Quidway>display current-configuration
#
!Software Version V100R006C00SPC800
sysname Quidway
#
vlan batch 1
#
cluster enable
ntdp enable
ntdp hop 16
ndp enable
#
dhcp enable
#
undo http server enable
#
drop illegal-mac alarm
#
aaa
authentication-scheme default
a
d
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 6 Verifying the Upgrade
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
47
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 7 Version Rollback
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
48
7 Version Rollback
7.1 S2700 Version Rollback
If an error occurs after the upgrade, perfor
operating.
Rollback Flowchart
m version rollback to restore normal service
7.1.1 Version
Figure 7-1 Version rollback flowchart
End
Start
Load previous
softwar
See 7.1.2
e package
Perform version rollback See 7.1.3
Verify version rollback See 7.1.4
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 7 Version Rollback
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
49
1. Only the configuration file in cfg format can be used for rollback. Before performing
version rollback, check the format of the configuration file. If the configuration file is not in
elete files stored in the flash memory before the device
is rolled back from V100R006SPC500 to V100R006, some space in the flash memory may be
d
cfg format, save it in the cfg format.
2. If you run the delete command to d
unavailable. Run the dir command to view the unknown space and run the fixdisk comman
to reclaim the space.
7.1.2 Loading the Previous System Software
vious system software package is the same as the procedure
For details, see chapter 4 Upgrade Operations
7.1.3 Perform
as the version upgrade method. For details, see
Switch.
7.1.4 Verifyi
same as the verification of version upgrade. For
e.
The procedure for loading the pre
for loading the system software for the upgrade.
on a Single Switch.
ing Version Rollback
The version rollback method is the same
chapter 4 Upgrade Operations on a Single
ng Version Rollback
The verification of version rollback is the
details, see chapter 6 Verifying the Upgrad
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 7 Version Rollback
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
50
7.2 S3700 Version Rollback
7.2.1 Version Rollback Flowchart
Figure 7-2 Version rollback flowchart
Start
Load previous
software package
See 7.2.2
Perform version rollback See 7.2.3
Verify version rollback See 7.2.4
End
1. When the S3728 V100R006C00SPC800 is rolled back to the S3728 V100R006C00, the
2. Only the configuration file in cfg format can be used for rollback. Before performing
version rollback, check the format of the configuration file. If the configuration file is not in
cfg format, save it in the cfg format.
3. If you run the delete command to delete files stored in the flash memory before the device
is rolled back from V100R006SPC500 to V100R006, some space in the flash memory may be
unavailable. Run the dir command to view the unknown space and run the fixdisk command
output information may be different from the normal output information displayed during
upgrade.
to reclaim the space.
7.2.2 Loading the Previous System Software
The procedure for loading the previous system software package is the same as the procedure
for loading the system software for the upgrade. For details, see chapters 4 Upgrade
Operations on a Single Switch or 5 Upgrade Operations on a Stack.
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 7 Version Rollback
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
51
7.2.3 Performing Version Rollback
The version rollback method is the same as the version upgrade method. For details, see
chapters X4 XXUpgrade Operations on a Single SwitchX or X5 XXUpgrade Operations on a StackX.
7.2.4 Verifying Version Rollback
The verification of version rollback is the same as the verification of version upgrade. For
details, see chapter X6 XXVerifying the UpgradeX.
7.3 S5700 Version Rollback
7.3.1 Version Rollback Flowchart
Figure 7-3 Version rollback flowchart
End
Start
Load previous
software package
See 7.3.2
Perform version rollback See 7.3.3
Verify version rollback See 7.3.4
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches
Upgrade Guide 7 Version Rollback
Issue 01 (2011-09-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd
52
When the S5700 V100R006C00SPC800 is rolled back to the S5700 V100R006, pay attention
to the following point:
Only the configuration file in cfg format can be used for rollback. Before performing
version rollback, check the format of the configuration file. If the configuration file is not
in cfg format, save it in the cfg format.
BootROM cannot be used for version rollback on the S5700SI, and the S5700SI cannot be
powered off during a version rollback.
If you run the delete command to delete files stored in the flash memory before the device
is rolled back from V100R006SPC500 to V100R006, some space in the flash memory
may be unavailable. Run the dir command to view the unknown space and run the fixdisk
command to reclaim the space.
7.3.2 Loading the Previous System Software
The procedure for loading the previous system software package is the same as the procedure
for loading the system software for the upgrade. For details, see chapters X4 XXUpgrade
Operations on a Single SwitchX or X5 XXUpgrade Operations on a StackX.
7.3.3 Performing Version Rollback
The version rollback method is the same as the version upgrade method. For details, see
chapters X4 XXUpgrade Operations on a Single SwitchX or X5 XXUpgrade Operations on a StackX.
7.3.4 Verifying Version Rollback
The verification of version rollback is the same as the verification of version upgrade. For
details, see chapter X6 XXVerifying the UpgradeX.

More Related Content

Similar to Quidway s2700/s3700/s5700/s6700 v100 r006c00spc800 upgrade guide

Configuration guide ethernet(v100 r006c01-02)
Configuration guide   ethernet(v100 r006c01-02)Configuration guide   ethernet(v100 r006c01-02)
Configuration guide ethernet(v100 r006c01-02)Edgar Rocha
 
Configuration guide basic configurations(v800 r002c01-01)
Configuration guide   basic configurations(v800 r002c01-01)Configuration guide   basic configurations(v800 r002c01-01)
Configuration guide basic configurations(v800 r002c01-01)Ghulam Mohyud Din
 
Cisco router commands vs huawei router commands
Cisco router commands vs huawei router commands Cisco router commands vs huawei router commands
Cisco router commands vs huawei router commands Roxanne Munnidoo
 
3900 Series Base Station Product Description.pdf
3900 Series Base Station Product Description.pdf3900 Series Base Station Product Description.pdf
3900 Series Base Station Product Description.pdfSokrates5
 
Ne40 hardware-description
Ne40 hardware-descriptionNe40 hardware-description
Ne40 hardware-descriptionPrecious Kamoto
 
Ne40 hardware-description
Ne40 hardware-descriptionNe40 hardware-description
Ne40 hardware-descriptionPrecious Kamoto
 
Configuration guide basic configurations(v800 r002c01-01)
Configuration guide   basic configurations(v800 r002c01-01)Configuration guide   basic configurations(v800 r002c01-01)
Configuration guide basic configurations(v800 r002c01-01)KIRAN KUMAR M
 
Hauwei Bts3900 gsm commissioning guide
Hauwei Bts3900 gsm  commissioning guideHauwei Bts3900 gsm  commissioning guide
Hauwei Bts3900 gsm commissioning guideengramjadislam78
 
Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01
Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01
Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01moussaCoulibaly22
 
Configuration Guide - Reliability(V100R006C01_01).pdf
Configuration Guide - Reliability(V100R006C01_01).pdfConfiguration Guide - Reliability(V100R006C01_01).pdf
Configuration Guide - Reliability(V100R006C01_01).pdfKiuHongAnh1
 
E nodeb kpi reference(v100r005c00 02)(pdf)-en
E nodeb kpi reference(v100r005c00 02)(pdf)-enE nodeb kpi reference(v100r005c00 02)(pdf)-en
E nodeb kpi reference(v100r005c00 02)(pdf)-entharinduwije
 
KPI Reference.pdf
KPI Reference.pdfKPI Reference.pdf
KPI Reference.pdfKamel Ardam
 
209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01
209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01
209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01Sam Rich
 
huawei-lte-kpi-ref
huawei-lte-kpi-refhuawei-lte-kpi-ref
huawei-lte-kpi-refAbd Yehia
 
OptiX_RTN_905_1E_2E_Radio_Transmission_S.pdf
OptiX_RTN_905_1E_2E_Radio_Transmission_S.pdfOptiX_RTN_905_1E_2E_Radio_Transmission_S.pdf
OptiX_RTN_905_1E_2E_Radio_Transmission_S.pdfHabtamuAdera3
 
Configuration guide vpn(v200 r002c00-02)
Configuration guide   vpn(v200 r002c00-02)Configuration guide   vpn(v200 r002c00-02)
Configuration guide vpn(v200 r002c00-02)mohsin225
 
Configuration guide basic configuration(v100 r006c00-01)
Configuration guide   basic configuration(v100 r006c00-01)Configuration guide   basic configuration(v100 r006c00-01)
Configuration guide basic configuration(v100 r006c00-01)Ivo Rodrigues
 
Mstp+ network design service product v100 r001 delivery guide(20100127)
Mstp+ network design service product v100 r001 delivery guide(20100127)Mstp+ network design service product v100 r001 delivery guide(20100127)
Mstp+ network design service product v100 r001 delivery guide(20100127)Emmanuel Ndahimana
 
Ma5631 configuration guide(v800 r308c02 02)
Ma5631 configuration guide(v800 r308c02 02)Ma5631 configuration guide(v800 r308c02 02)
Ma5631 configuration guide(v800 r308c02 02)Jb Menezes
 

Similar to Quidway s2700/s3700/s5700/s6700 v100 r006c00spc800 upgrade guide (20)

Configuration guide ethernet(v100 r006c01-02)
Configuration guide   ethernet(v100 r006c01-02)Configuration guide   ethernet(v100 r006c01-02)
Configuration guide ethernet(v100 r006c01-02)
 
Configuration guide basic configurations(v800 r002c01-01)
Configuration guide   basic configurations(v800 r002c01-01)Configuration guide   basic configurations(v800 r002c01-01)
Configuration guide basic configurations(v800 r002c01-01)
 
Cisco router commands vs huawei router commands
Cisco router commands vs huawei router commands Cisco router commands vs huawei router commands
Cisco router commands vs huawei router commands
 
Mkb o2
Mkb o2Mkb o2
Mkb o2
 
3900 Series Base Station Product Description.pdf
3900 Series Base Station Product Description.pdf3900 Series Base Station Product Description.pdf
3900 Series Base Station Product Description.pdf
 
Ne40 hardware-description
Ne40 hardware-descriptionNe40 hardware-description
Ne40 hardware-description
 
Ne40 hardware-description
Ne40 hardware-descriptionNe40 hardware-description
Ne40 hardware-description
 
Configuration guide basic configurations(v800 r002c01-01)
Configuration guide   basic configurations(v800 r002c01-01)Configuration guide   basic configurations(v800 r002c01-01)
Configuration guide basic configurations(v800 r002c01-01)
 
Hauwei Bts3900 gsm commissioning guide
Hauwei Bts3900 gsm  commissioning guideHauwei Bts3900 gsm  commissioning guide
Hauwei Bts3900 gsm commissioning guide
 
Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01
Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01
Bts3900gsmcommissioningguide v300r00803-131111044049-phpapp01
 
Configuration Guide - Reliability(V100R006C01_01).pdf
Configuration Guide - Reliability(V100R006C01_01).pdfConfiguration Guide - Reliability(V100R006C01_01).pdf
Configuration Guide - Reliability(V100R006C01_01).pdf
 
E nodeb kpi reference(v100r005c00 02)(pdf)-en
E nodeb kpi reference(v100r005c00 02)(pdf)-enE nodeb kpi reference(v100r005c00 02)(pdf)-en
E nodeb kpi reference(v100r005c00 02)(pdf)-en
 
KPI Reference.pdf
KPI Reference.pdfKPI Reference.pdf
KPI Reference.pdf
 
209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01
209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01
209261635 huawei-lte-kpi-ref-150429104255-conversion-gate01
 
huawei-lte-kpi-ref
huawei-lte-kpi-refhuawei-lte-kpi-ref
huawei-lte-kpi-ref
 
OptiX_RTN_905_1E_2E_Radio_Transmission_S.pdf
OptiX_RTN_905_1E_2E_Radio_Transmission_S.pdfOptiX_RTN_905_1E_2E_Radio_Transmission_S.pdf
OptiX_RTN_905_1E_2E_Radio_Transmission_S.pdf
 
Configuration guide vpn(v200 r002c00-02)
Configuration guide   vpn(v200 r002c00-02)Configuration guide   vpn(v200 r002c00-02)
Configuration guide vpn(v200 r002c00-02)
 
Configuration guide basic configuration(v100 r006c00-01)
Configuration guide   basic configuration(v100 r006c00-01)Configuration guide   basic configuration(v100 r006c00-01)
Configuration guide basic configuration(v100 r006c00-01)
 
Mstp+ network design service product v100 r001 delivery guide(20100127)
Mstp+ network design service product v100 r001 delivery guide(20100127)Mstp+ network design service product v100 r001 delivery guide(20100127)
Mstp+ network design service product v100 r001 delivery guide(20100127)
 
Ma5631 configuration guide(v800 r308c02 02)
Ma5631 configuration guide(v800 r308c02 02)Ma5631 configuration guide(v800 r308c02 02)
Ma5631 configuration guide(v800 r308c02 02)
 

Recently uploaded

如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一ga6c6bdl
 
(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...
(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...
(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...ranjana rawat
 
定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一
定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一
定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一zul5vf0pq
 
Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...
Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...
Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...anilsa9823
 
Dubai Call Girls O528786472 Call Girls In Dubai Wisteria
Dubai Call Girls O528786472 Call Girls In Dubai WisteriaDubai Call Girls O528786472 Call Girls In Dubai Wisteria
Dubai Call Girls O528786472 Call Girls In Dubai WisteriaUnited Arab Emirates
 
Thane Escorts, (Pooja 09892124323), Thane Call Girls
Thane Escorts, (Pooja 09892124323), Thane Call GirlsThane Escorts, (Pooja 09892124323), Thane Call Girls
Thane Escorts, (Pooja 09892124323), Thane Call GirlsPooja Nehwal
 
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝soniya singh
 
VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...
VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...
VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...Call Girls in Nagpur High Profile
 
Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...
Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...
Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...nagunakhan
 
(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service
(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service
(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls KolkataCall Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkataanamikaraghav4
 
Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...
Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...
Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...Pooja Nehwal
 
9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...
9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...
9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...Pooja Nehwal
 
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一ga6c6bdl
 
Alambagh Call Girl 9548273370 , Call Girls Service Lucknow
Alambagh Call Girl 9548273370 , Call Girls Service LucknowAlambagh Call Girl 9548273370 , Call Girls Service Lucknow
Alambagh Call Girl 9548273370 , Call Girls Service Lucknowmakika9823
 
Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...
Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...
Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...Pooja Nehwal
 
VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...
VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...
VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...Call Girls in Nagpur High Profile
 
哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样
哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样
哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样qaffana
 
Vip Noida Escorts 9873940964 Greater Noida Escorts Service
Vip Noida Escorts 9873940964 Greater Noida Escorts ServiceVip Noida Escorts 9873940964 Greater Noida Escorts Service
Vip Noida Escorts 9873940964 Greater Noida Escorts Serviceankitnayak356677
 

Recently uploaded (20)

如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
如何办理萨省大学毕业证(UofS毕业证)成绩单留信学历认证原版一比一
 
(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...
(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...
(MEGHA) Hinjewadi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune E...
 
定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一
定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一
定制加拿大滑铁卢大学毕业证(Waterloo毕业证书)成绩单(文凭)原版一比一
 
Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...
Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...
Lucknow 💋 Call Girls Adil Nagar | ₹,9500 Pay Cash 8923113531 Free Home Delive...
 
🔝 9953056974🔝 Delhi Call Girls in Ajmeri Gate
🔝 9953056974🔝 Delhi Call Girls in Ajmeri Gate🔝 9953056974🔝 Delhi Call Girls in Ajmeri Gate
🔝 9953056974🔝 Delhi Call Girls in Ajmeri Gate
 
Dubai Call Girls O528786472 Call Girls In Dubai Wisteria
Dubai Call Girls O528786472 Call Girls In Dubai WisteriaDubai Call Girls O528786472 Call Girls In Dubai Wisteria
Dubai Call Girls O528786472 Call Girls In Dubai Wisteria
 
Thane Escorts, (Pooja 09892124323), Thane Call Girls
Thane Escorts, (Pooja 09892124323), Thane Call GirlsThane Escorts, (Pooja 09892124323), Thane Call Girls
Thane Escorts, (Pooja 09892124323), Thane Call Girls
 
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
Call Girls in Dwarka Sub City 💯Call Us 🔝8264348440🔝
 
VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...
VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...
VVIP Pune Call Girls Balaji Nagar (7001035870) Pune Escorts Nearby with Compl...
 
Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...
Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...
Russian Call Girls In South Delhi Delhi 9711199012 💋✔💕😘 Independent Escorts D...
 
(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service
(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service
(SANA) Call Girls Landewadi ( 7001035870 ) HI-Fi Pune Escorts Service
 
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls KolkataCall Girls Service Kolkata Aishwarya 🤌  8250192130 🚀 Vip Call Girls Kolkata
Call Girls Service Kolkata Aishwarya 🤌 8250192130 🚀 Vip Call Girls Kolkata
 
Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...
Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...
Kalyan callg Girls, { 07738631006 } || Call Girl In Kalyan Women Seeking Men ...
 
9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...
9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...
9892124323, Call Girl in Juhu Call Girls Services (Rate ₹8.5K) 24×7 with Hote...
 
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
如何办理(NUS毕业证书)新加坡国立大学毕业证成绩单留信学历认证原版一比一
 
Alambagh Call Girl 9548273370 , Call Girls Service Lucknow
Alambagh Call Girl 9548273370 , Call Girls Service LucknowAlambagh Call Girl 9548273370 , Call Girls Service Lucknow
Alambagh Call Girl 9548273370 , Call Girls Service Lucknow
 
Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...
Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...
Call Girls in Thane 9892124323, Vashi cAll girls Serivces Juhu Escorts, powai...
 
VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...
VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...
VVIP Pune Call Girls Warje (7001035870) Pune Escorts Nearby with Complete Sat...
 
哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样
哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样
哪里办理美国宾夕法尼亚州立大学毕业证(本硕)psu成绩单原版一模一样
 
Vip Noida Escorts 9873940964 Greater Noida Escorts Service
Vip Noida Escorts 9873940964 Greater Noida Escorts ServiceVip Noida Escorts 9873940964 Greater Noida Escorts Service
Vip Noida Escorts 9873940964 Greater Noida Escorts Service
 

Quidway s2700/s3700/s5700/s6700 v100 r006c00spc800 upgrade guide

  • 1. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches V100R006C00SPC800 Upgrade Guide Issue 01 Date 2011-09-30 HUAWEI TECHNOLOGIES CO., LTD.
  • 2. Copyright © Huawei Technologies Co., Ltd. 2011. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd i
  • 3. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide Change History Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd ii Change History Changes between document issues are cumulative. The latest document issue contains all the changes in earlier issues. Issue 01 (2011-09-30) This issue is the first official release.
  • 4. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide Contents Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd iii Contents Change History................................................................................................................................ ii 1 Before You Start.............................................................................................................................1 1.1 Version Requirements Before Upgrade............................................................................................................1 1.2 Impact of Patch Installation..............................................................................................................................1 1.3 Impact on the System During Installation........................................................................................................1 1.3.1 Impact on the System After Installation..................................................................................................2 1.4 Cautionary Notes Before the Upgrade .............................................................................................................2 2 Upgrade Process ............................................................................................................................4 2.1 Upgrade Flowchart...........................................................................................................................................4 3 Preparations for Upgrade ............................................................................................................5 3.1 Preparation Checklist .......................................................................................................................................5 3.2 Checking the Current System Software Version ..............................................................................................6 3.3 Checking the Running Status of the Device.....................................................................................................6 3.4 Setting Up an Environment for the Upgrade....................................................................................................6 3.5 Obtaining Required Software for the Upgrade.................................................................................................8 3.6 Backing Up the Key Data in the Flash Memory ..............................................................................................9 3.7 Checking the Flash Memory Space..................................................................................................................9 4 Upgrade Operations on a Single Switch ................................................................................12 4.1 Upgrading the Switch to V100R006C00SPC800 Using the Command Line.................................................12 4.2 Upgrading the Switch to the V100R006C00SPC800 Using the BootROM...................................................21 4.2.1 Upgrading the BootROM......................................................................................................................22 4.2.2 Uploading the System Software............................................................................................................26 4.2.3 Specifying the System Software to Be Loaded for Starting the Switch................................................31 4.2.4 Restarting the Switch ............................................................................................................................33
  • 5. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide Contents Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd iv 4.3 Upgrading the S5700-SI to V100R006C00SPC800 Using the USB Flash Drive ..........................................33 4.3.1 Overview...............................................................................................................................................33 4.3.2 Upgrading the Software Using the USB Flash Drive............................................................................34 5 Upgrade Operations on a Stack................................................................................................38 5.1 Upgrading All Stack Member Switches to V100R006C00SPC800 by Using the Command Line ................38 5.2 Using the Intelligent Upgrade Function .........................................................................................................41 5.2.1 Overview...............................................................................................................................................41 5.2.2 Upgrading a New Member Switch Using the Intelligent Upgrade Function ........................................42 6 Verifying the Upgrade ...............................................................................................................45 6.1 Verification Checklist.....................................................................................................................................45 6.2 Checking the Current System Software Version ............................................................................................45 6.3 Checking the Device Running Status.............................................................................................................46 6.4 Checking the System Configuration...............................................................................................................46 7 Version Rollback.........................................................................................................................48 7.1 S2700 Version Rollback.................................................................................................................................48 7.1.1 Version Rollback Flowchart..................................................................................................................48 7.1.2 Loading the Previous System Software ................................................................................................49 7.1.3 Performing Version Rollback................................................................................................................49 7.1.4 Verifying Version Rollback...................................................................................................................49 7.2 S3700 Version Rollback.................................................................................................................................50 7.2.1 Version Rollback Flowchart..................................................................................................................50 7.2.2 Loading the Previous System Software ................................................................................................50 7.2.3 Performing Version Rollback................................................................................................................51 7.2.4 Verifying Version Rollback...................................................................................................................51 7.3 S5700 Version Rollback.................................................................................................................................51 7.3.1 Version Rollback Flowchart..................................................................................................................51 7.3.2 Loading the Previous System Software ................................................................................................52 7.3.3 Performing Version Rollback................................................................................................................52 7.3.4 Verifying Version Rollback...................................................................................................................52
  • 6. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 1 Before You Start Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 1 1 Before You Start 1.1 Version Requirements Before Upgrade T efore uable 1-1 Version requirements b pgrade Version Upgrade Instruction S2700, S3700, S5700, S6 V100R006C00SPC300 700 V100R006C00SPC500 V100R006C00SPC600 This version can be directly upgraded to V100R006C00SPC800. 1.2 Impact Before you upgrade an earlier version to the V100R006C00SPC800, read this chapter ing system. he System During Installation Impact on Servic The of Patch Installation carefully to understand the possible impacts of the upgrade on the exist 1.3 Impact on t es switch will restart during the upgrade and service will be interrupted.
  • 7. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 1 Before You Start Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 2 NOTE The service interruption time depends on many factors, such as the system software size, upgrade method, operator's skill, and service configurations. The following service interruption time is for your owing examples, the switches are not configured and they are not in any stack. In addition, all these switches can provide the PoE function. ed by using the BootROM and the system software is uploaded throu e, the service interruption time is as follows (the baudrate is 52 If the swit ed by using the BootROM and the system software is uploaded ou TP mode), the service interruption time is as follows: 0: 5.5 minutes If the ded by using the command line, the service interruption time is as When the system restarts, the communication between the switch and the NMS is interrupted. e as the service interruption time. 1.3.1 Impact on the System After Installation 1.4 Cautionar reference. In the foll If the switches are upgrad gh the serial interfac 11 00): S2700: 30 minutes S3700: 37 minutes S5700: 44 minutes ches are upgrad thr gh the network port (F S2700: 5.5 minutes S370 S5700: 6 minutes switches are upgra follows: S2700: 3 minutes S3700: 3 minutes S5700: 3 minutes Impact on Network Communication The communication interruption time is the sam There is no adverse impact on the system. y Notes Before the Upgrade Consider the following cautionary points before performing the upgrade:
  • 8. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 1 Before You Start Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 3 The flash memory of the S3728/S3752/S2752 can store only one startup file; therefo delete the current startup file before performing the upgrade. (If there are remaining files in the flash memory, delete them.) When you upgrade re, the software using the command line, stack upgrade, or USB flash not saved, the configuration will be lost in the case of command in the interface view after the upgrade; otherwise, the MAC swap loopback configuration will be invalid. After the arp learning dhcp-trigger command is used on a VLANIF interface of the DHCP relay agent in V100R006, dynamic ARP entries are generated only after DHCP snooping in the corresponding VLAN or on the physical interface connected to users. drive, do not copy or delete files. After the version is upgraded, ensure that the configuration is saved because a later version is compatible with early versions but an early version is incompatible with later versions. If the configuration is version rollback. If the loopback local swap-mac or loopback remote swap-mac command has been used on an interface in V100R006 to configure MAC swap loopback, run the start
  • 9. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 2 Upgrade Process Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 4 2 Upgrade Process 2.1 Upgrade Flowchart Figure 2-1 Upgrade flowchart Start Preparation Upgrade See chapter 3 See chapters 4 and 5 Verification See chapter 6 Rollback See chapter 7 Yes Yes No End Yes NOTE In the following chapters, the version is upgraded to V100R006C00SPC800.
  • 10. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 5 3 Preparations for Upgrade 3.1 Prepara Table 3-1 t tion Checklist Upgrade preparation checklis No. Item Check Point Result 1 Check the system software version The system software version is between V100R006 and V100R006C00SPC800. 2 running status of normally.Check the the device The switch functions 3 ironment for the ent is set up for theSet up an env upgrade An environm upgrade as required. 4 software for uired for the upgrade isObtain required the upgrade Software req obtained. 5 ta in the flash memory ory isBack up the key da All the key data in the flash mem backed up. 6 Check the available space in the flash memory The space in the flash memory is sufficient for storing the system software package and other files such as patch files and configuration files. e.In the following sections, the S2700 is used as an example to describe the upgrad
  • 11. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 6 3.2 Checking the Current System Software Version un the display version command to view the version of the system software. ion Routing Platform Software 700 V100R006C00) EDFEA 0(Master) : EDFE uptime is 0 day, 0 hour, 1 minute 3.3 Checking the Running Status of the Device Status is Normal, the device can be upgraded. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3.4 Setting Setting Up an Envir ading the System Using TFTP or FTP Transfer Protocol (FTP) to download the system software, and set it th e. Figure s stem using P ent for upgrading the system using TFTP or FTP are as follows: You can log in to the switch from a PC through the serial interface or Telnet. The server and the switch can communicate with each other. Files for the upgrade are stored in the server. R <Quidway> display vers Huawei Versatile VRP (R) Software, Version 5.70 (S2 Copyright (C) 2003-2010 HUAWEI TECH Co., Ltd. Quidway S2718TP-SI Routing Switch uptime is 0 day, 0 hour, 1 minute 64M bytes DDR Memory 16M bytes FLASH Pcb Version : CX22EDFE REV C Basic BOOTROM Version : 118 Compiled at Nov 4 2009, 17:23:15 Software Version : VRP (R) Software, Version 5.70 (S2700 V100R006C00) Run the display device command to check the switch running status. If the value of <Quidway> display device P S2718TP-EI's Device status: Slot Sub Type Online Power Register Status Role 0 - 2718F Present PowerOn Registered Normal Master Up an Environment for the Upgrade onment for Upgr In the BootROM menu or the command line view, you can use the Trivial File Transfer Protocol (TFTP) or File as e next startup system software. Then restart the device to complete the upgrad 3-1 hows the network diagram for setting up an environment for upgrading the sy FT or TFTP. The general requirements for setting up an environm
  • 12. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 7 Figure 3-1 Network diagram of upgrading the system using TFTP or FTP Setting Up an Environment for Upgrading the System Using Xmodem You can upgrade the basic and advanced BootROM software using Xmodem in the basic BootROM menu; you can upgrade the system software using Xmodem in the BootROM menu. Figure 3-2 shows the network diagram for setting up an environment for upgrading the system using Xmodem. The general requirements for setting up an environment for upgrading the system using Xmodem are as follows: The RS-232 serial interface on the PC and the console interface on the switch are connected through a console cable. Files for the upgrade are stored on the PC. Figure 3-2 Network diagram of upgrading the system using Xmodem
  • 13. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 8 3.5 Obtaining Required Software for the Upgrade To obtain the required software for the upgrade, contact Huawei technical support personnel. Table 3-2 Software for different upgrade methods Upgrade Method Matching Software Upgrading the version to V100R006C00SPC800 using the command line System software S2700: S2700-V100R006C00SPC800.CC S2752: S2700_52P-V100R006C00SPC800.CC S3728: S3700_28TP-V100R006C00SPC800.CC S3752: S3700_52P-V100R006C00SPC800.CC S5700-EI: S5700EI-V100R006C00SPC800.CC S5700-SI: S5700SI-V100R006C00SPC800.CC S6700: S6700-V100R006C00SPC800.CC
  • 14. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 9 Upgrade Method Matching Software Upgrading the version to V100R006C00SPC800 using BootROM BootROM S2700: S2700_bootrom.bin S2752: S2700_52P_bootrom.bin S3728: S3700_28TP_bootrom.bin S3752: S3700_52P_bootrom.bin S5700-EI: S5700EI_bootrom.bin S5700-SI: S5700SI_bootrom.bin S6700: S6700_bootrom.bin System software S2700: S2700-V100R006C00SPC800.CC S2752: S2700_52P-V100R006C00SPC800.CC S3728: S3700_28TP-V100R006C00SPC800.CC S3752: S3700_52P-V100R006C00SPC800.CC S5700-EI: S5700EI-V100R006C00SPC800.CC S5700-SI: S5700SI-V100R006C00SPC800.CC S6700: S6700-V100R006C00SPC800.CC 3.6 Backing Up the Key Data in the Flash Memory You must back up the key data stored in the flash memory before the upgrade. You can download the data that needs to be backed up to the PC through FTP or TFTP. After the upgrade, you can reload the backup files to the flash memory. For details, see 4.1 Upgrading the Switch to V100R006C00SPC800 Using the Command Line. 3.7 Checking the Flash Memory Space 1. Run the dir command in the user view to check whether the flash memory space is sufficient for the system software. If a stack is established, ensure that all the members in the stack have enough space.
  • 15. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 10 The preceding information shows that there is 2,266 KB space. If there is enough space, ignore step 2. <Quidway> dir Directory of flash:/ Idx Attr Size(Byte) Date Time(LMT) FileName 0 -rw- 6,458,620 Jan 08 2008 03:35:29 s2700-v100r006c00.cc 1 -rw- 603 Jan 02 2008 02:57:45 vrpcfg.zip 2 -rw- 628 Jan 01 2008 00:00:52 private-data.txt 3 -rw- 6,177,996 Jan 02 2008 02:57:00 s-s2700.cc 14,632 KB total (2,266 KB free) 2. (Optional) Load and activate the patch file S27_37_57-V100R006SPH005.pat. Before upgrading an S2752 or S3700 to V100R006, delete the current startup file to free up the flash memory space. If no system software is stored on the device, do not restart or power cycle the device during the upgrade. Otherwise, the system may break down. If the device is powered off unexpectedly during the upgrade, use the BootROM to upgrade the device. If the upgrade using BootROM fails, contact Huawei engineers. 3. Run the delete command to delete unnecessary files to ensure there is enough space for storing relevant upgrade files. Before deleting the unnecessary files, ensure that the files are backed up or are unwanted. The following is an example of deleting the s-s2700.cc file. For details, see "Managing the File System" in the Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Configuration Guide – Basic Configurations. After you run the delete /unreserved command to delete a file from the flash, the file cannot be restored; therefore, run this command with caution, and a file backup is recommended. <Quidway> delete /unreserved s-s2700.cc Warning: The contents of file flash:/ s-s2700.cc cannot be recycled. Continue? [Y/N]:y Info: Deleting file flash:/ s-s2700.cc... Deleting file permanently from flash will take a long time if needed....... ................................................................................ ................................................................................ ................................................................................ ................................................................................ ................................................................................ ................................................................................su cceeded.
  • 16. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 11 ----End
  • 17. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 12 4 Upgrade Operations on a Single Switch 4.1 Upgrading the Switch to V100R006C00SPC800 Using the Comm The command line upgrade method has little impact on services; therefore, you are advised to u operatin and Line pgrade an g device by using the command line. To upgrade the system softwarePurpose Services are interrupted when the device restarts.Impact In the scenario where a single device is configured and service deployment is simple, services are interrupted about three minutes. In in time increases and the time depends on the complexity of Time Required the scenario where service deployment is complicated, the service terruption service. Requirements ns system software of an earlier version functions properly. The available space in the flash memory is sufficient for storing the system software. The switch that ru The S5700/S6700 has a dedicated management interface, namely, MEth. The MEth interface can be Before the upgrade, use the terminal monitor command to enable the terminal to display logs, traps, the information center. u ds to load the system software: Before the S2752/S3700 is upgraded, you must delete the original startup file. For details on how to delete the original startup file, see section 3.7 Checking the Flash Memory Space. The methods of upgrading the system software using command line are similar on the S2700, S3700, S5700, and the S6700. In the following description, the system software of the S2700 is upgraded. used as the Layer 3 interface. and debugging information sent from Yo can use any of the following metho
  • 18. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 13 Use the S2700 as the TFTP client. Use the S2700 as the FTP server. Method 1: Use th Use the S2700 as the FTP client. e S2700 as the TFTP Client No TFTP client software is installed on the S2700; therefore, the customer needs to buy TFTP client software and install it. The TFTP32 program is recommended. 1. Configure the TFTP server. n he system, for can manually change Ru the TFTP server program on the PC and configure the PC: Click Browse to set the directory for storing the new system software. The TFTP server address in Server interface is automatically set by t example, 10.164.30.29. However, if the IP address is incorrect you it. Do not stop the TFTP server program when you are backing up data. 2. Back up the system software, configuration file, and patch files to the TFTP server.
  • 19. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 14 Before the backup, check the size of the configuration file. After the backup, compare the size o files are the same size. uidway> dir *.cc te) Date Time(LMT) FileName 0 -rw- 6,472,284 Nov 04 2010 19:43:18 s2700-v100r006c00.cc uidway> dir *.zip te) Date Time(LMT) FileName 0 -rw- 589 Nov 04 2010 20:55:54 vrpcfg.zip uidway> dir *.pat 14,632 KB total (8,228 KB free) are atch -v100r006c00-bak.cc 27_37_57-v100r006sph005.pat s27_37_57-v100r006sph005-bak.pat Uploading the file to the remote TFTP server. Please wait... 3. from the server. <Quidway> tftp 10.164.30.29 get S2700-V100R006C00SPC800.cc the file from the remote TFTP server. Please wait.../ TFTP: Downloading the file successfully. If the message "Downloading the file successfully" is displayed, the system software has been 4. of the original file with the size of the backup file. Ensure that the tw <Q Directory of flash:/ Idx Attr Size(By 14,632 KB total (8,228 KB free) <Q Directory of flash:/ Idx Attr Size(By 14,632 KB total (8,228 KB free) <Q Directory of flash:/ Idx Attr Size(Byte) Date Time(LMT) FileName 0 -rw- 333,436 Jan 29 2010 16:54:40 S27_37_57-V100R006SPH005.pat Run the following commands on the S2700 to back up the data. The backup system softw is s2700-v100r006c00-bak.cc, the backup configuration file is vrpcfg-bak.zip, and the p file is s27_37_57-v100r006sph005-bak.pat. <Quidway> tftp 10.164.30.29 put s2700-v100r006c00.cc s2700 Info: Transfer file in binary mode. Uploading the file to the remote TFTP server. Please wait...| TFTP: Uploading the file successfully. 6472284 bytes send in 91 seconds. <Quidway> tftp 10.164.30.29 put vrpcfg.zip vrpcfg-bak.zip Info: Transfer file in binary mode. Uploading the file to the remote TFTP server. Please wait.../ TFTP: Uploading the file successfully. 589 bytes send in 0.01 second. <Quidway> tftp 10.164.30.29 put s Info: Transfer file in binary mode. TFTP: Uploading the file successfully. 333436 bytes send in 1 second. Obtain the system software of the target version Info: Transfer file in binary mode. Downloading 6502764 bytes received in 63 seconds downloaded. (Optional) Obtain the new configuration file from the server.
  • 20. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 15 If the configuration file does not need to be changed after the upgrade, this step is not gnew.zip Info: Transfer file in binary mode. TFTP: Downloading the file successfully. 5. system software in service, which is loaded when the S2700 is started. <Qui .cc required. <Quidway> tftp 10.164.30.29 get vrpcf Downloading the file from the remote TFTP server. Please wait.../ 2757 bytes received in 1 second. Specify the dway> startup system-software s2700-V100R006C00SPC800.cc If the following information is displayed after you run the startup syste Y to update the BootROM. If the BootROM is upgraded successfully, go m-software file command, enter to step 7; otherwise, go to step 6. [N]: y BOOTROM begin to be upgraded ! please wait for a moment Info: BOOTROM UPGRADE OK 6. he S2700 is started. uidway> system-view otrom s2700-V100R006C00SPC800.cc BOOTROM begin to upgraded ! please wait for a minute... Info Succ Warning: Basic BOOTROM will be upgraded. Continue?(Y/N) Succeeded in setting the software for booting system. Upgrade the BootROM in service, which is loaded when t <Q [Quidway] upgrade basic-bo Confirm basic BOOTROM will be upgrade?(Y/N)[N]: y : BOOTROM UPGRADE OK eeded in setting the software for booting system. In the V100R005 and V100R006, the BootROM is upgraded automatically. To upgrade the software to u must upgrade the BootROM manually. For details about automatic BootROM upgrade, see Step 5. In the case of a version rollback, you are advised to manually upgrade the BootROM to prevent a rollback failure 7. Res other versions, yo tart the S2700. ified or the invalid software is specified, the device will fail to ystem software for next startup, see step 5. fter the setting is ion, please wait. d to the configuration file for the next :y Now saving the current configuration to the slot 0. ve the configuration successfully. System will reboot! Continue?[Y/N]: y Info: system is rebooting, please wait… After the software is upgraded to V100R006C00SPC800, you must specify the system software for next startup. If the system software is not spec restart. For details about specifying the s When the system asks you whether to save the configuration, enter y or n. A complete, enter y to restart the system. <Quidway> reboot Info: The system is now comparing the configurat Warning: All the configuration will be save startup:flash:/vrpcfg.zip, Continue?[Y/N] Info: Sa
  • 21. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 16 ----End Method 2: Use the S2700 as the FTP Server No FTP server software is installed on the S2700; therefore, the customer needs to buy FTP server 1. the S2700 as an FTP server. 0, and set the FTP user name to ftpuser and password to ser service-type ftp [Quidway-aaa] local-user ftpuser ftp-directory flash: 2. d. This example assumes that ethernet/0/0/1 is used ew port link-type access ernet 0/0/1 n10] quit 1.1 24 quit 3. Log software and install it. Configure Start the FTP server on the S270 ftppwd. <Quidway> system-view [Quidway] ftp server enable [Quidway] aaa [Quidway-aaa] local-user ftpuser password simple ftppwd [Quidway-aaa] local-user ftpu [Quidway-aaa] return Set an IP address for the S2700. An idle service interface is recommende and the IP address is 1.1.1.1/24. <Quidway> system-vi [Quidway]interface ethernet 0/0/1 [Quidway-Ethernet0/0/1] [Quidway-Ethernet0/0/1]quit [Quidway] vlan 10 [Quidway-vlan10] port eth [Quidway-vla [Quidway] interface vlanif 10 [Quidway-Vlanif10] ip address 1.1. [Quidway-Vlanif10] [Quidway] in to the FTP server (the S2700). Assume that the Windows XP operating system is used. Store the file to be uploaded in the specified directory (for example, D:>directory). Choose cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user at the password prompt, and then press Enter. The following o 1.1.1.1. . .1.1.1:(none)): ftpuser Start > Run. Enter prompt and the password information is displayed: D:>ftp 1.1.1.1 Connected t 220 FTP service ready User (1 331 Password required for 1. Password:
  • 22. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 17 230 User logged in. 4. onfiguration file, and patch files. ceived in 20.33Seconds 1350.65Kbytes/sec. nsferred and you can find it 60Kbytes/sec. n find it 226 Transfer complete. ds 1333.74Kbytes/sec. The preceding output indicates the configuration file has been transferred and you can find it 5. Upload the system software for the S2700. 0R006C00SPC800.CC. 226 Transfer complete. 6. (Optional) Upload the new configuration file to the S2700. ot required. put vrpcfgnew.zip 7. Spe <Quidway> startup system-software s2700-V100R006C00SPC800.cc ftp> Back up the system software, c ftp> binary 200 Type set to I. ftp> get s2700-v100r006c00.cc 200 Port command okay. 150 Opening BINARY mode data connection for s2700-v100r006c00.cc. 226 Transfer complete. ftp: 6472284 bytes re The preceding output indicates the configuration file has been tra in D:>. ftp> get vrpcfg.zip 200 Port command okay. 150 Opening BINARY mode data connection for vrpcfg.zip 226 Transfer complete. ftp: 589 bytes received in 0.01Seconds The preceding output indicates the configuration file has been transferred and you ca in D:>. ftp> get s27_37_57-v100r006sph005.pat 200 Port command okay. 150 Opening BINARY mode data connection for s27_37_57-v100r006sph005.pat. ftp: 333436 bytes received in 0.25Secon in D:>. Run the put source-filename [ destination-filename ] command on the FTP client (PC) to m the PC.upload the system software fro ftp> put D:S2700-V100R006C00SPC800.cc 200 Port command okay. 150 Opening BINARY mode data connection for S2700-V10 ftp: 6502764 bytes in 47.10Seconds 140.76Kbytes/sec. ftp> If the configuration file does not need to be changed after the upgrade, this step is n ftp> cify the system software in service, which is loaded when the S2700 is started.
  • 23. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 18 is displayed after you run the startup system-software file command, enter ly, go to step 9; otherwise, go to step raded ! please wait for a moment g system. 8. the BootROM in service, which is loaded when the S2700 is started. upgrade basic-bootrom s2700-V100R006C00SPC800.cc Warn Upgr [Slo If the following information Y to update the BootROM. If the BootROM is upgraded successful 8. Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y BOOTROM begin to be upg Info: BOOTROM UPGRADE OK Succeeded in setting the software for bootin (Optional) Upgrade <Quidway> system-view [Quidway] ing: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y ading BOOTROM,please wait for a moment t 0]: Info: BOOTROM UPGRADE OK. In the V e 100R005 and V100R006, the BootROM is upgraded automatically. To upgrade the software to 9. other v rsions, you must upgrade the BootROM manually. For details about automatic BootROM upgrade, see Step 7. In the case of a version rollback, you are advised to manually upgrade the BootROM to prevent a rollback failure Restart the S2700. After the software is upgraded to V100R006C00SPC800, you must specify the system software for next e device will fail to guration, enter y or n. After the setting is figuration, please wait. All the configuration will be saved to the configuration file for the next Now saving the current configuration to the slot 0. Info: Save the configuration successfully. y it… Method 3: Use the S2700 as the FTP Client startup. If the system software is not specified or the invalid software is specified, th restart. For details about specifying the system software for next startup, see step 7. When the system asks you whether to save the confi complete, enter y to restart the system. <Quidway> reboot Info: The system is now comparing the con Warning: startup:flash:/vrpcfg.zip, Continue?[Y/N]:y System will reboot! Continue?[Y/N]: Info: system is rebooting, please wa ----End No FTP client software is installed on the S2700; therefore, the customer needs to buy FTP client software and install it. 1. Configure the PC as the FTP server.
  • 24. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 19 Run an FTP server program on the PC, for example, wftpd32. Choose Users/rights. Security > Click New User to set the user name and password. Here, the user name is S2700 and the tory text box. Here, the root directory is D:ftp. Click Done to close the dialog box. Do not stop the FTP server program when you are backing up data. 2. he S2700 are the same as the FTP commands in the DOS system. server is 10.164.30.27, the FTP user name is S2700, user is 123456. Enter the user name and press Enter. ease : # Enter the password 123456 and press Enter. The password displayed xt. r and specify the name password is 123456. Enter the FTP root directory in the Home Direc Back up the system software, configuration file, and patch files. The FTP commands on t Assume that the IP address of the FTP and the password of the FTP <Quidway> cd flash:/ <Quidway> ftp 10.164.30.27 Trying 10.164.30.27 ... Press CTRL+K to abort Connected to 10.164.30.27. 220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user User(10.164.30.27:(none)):S2700 # 331 Give me your password, pl Enter password on the screen is in cipher te 230 Logged in successfully [ftp] binary 200 Type is Image (Binary) Back up the system software s2700-v100r006c00.cc to the FTP serve of the backup file as s2700-v100r006c00-bak.cc. If the name of the backup file is not specified, the original name is used. [ftp] put s2700-v100r006c00.cc s2700-v100r006c00-bak.cc 200 PORT command successful 150 Opening BINARY mode data connection for file transfer 226 Transfer complete. FTP: 6472284 byte(s) sent in 41.176 second(s) 1296.55Kbyte(s)/sec.
  • 25. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 20 Back up the configuration file vrpcfg.zip to the FTP server and specify the name of the backup file as vrpcfg-bak.zip. If the name of the backup file is not specified, the original [ftp] put vrpcfg.zip vrpcfg-bak.zip FTP: 1387 byte(s) sent in 0.176 second(s) 22.04Kbyte(s)/sec. cify the .pat 200 PORT command okay " file ready to receive in IMAGE / Binary mode FTP: 333436 byte(s) sent in 0.322 second(s) 1035.51Kbyte(s)/sec. 3. file transfer 226 Transfer complete. econd(s) 1117.40Kbyte(s)/sec. You can specify the filename of the upgrade program. If the filename is not specified, the 4. onfiguration file. s not need to be changed after the upgrade, this step is not 221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye 6. Spe <Quidway> startup system-software s2700-V100R006C00SPC800.cc name is used. 200 PORT command successful 150 Opening BINARY mode data connection for file transfer 226 Transfer complete. Back up the patch file s27_37_57-v100r006sph005.pat to the FTP server and spe name of the backup file as s27_37_57-v100r006sph005bak.pat. If the name of the backup file is not specified, the original name is used. [ftp] put s27_37_57-v100r006sph005.pat s27_37_57-v100r006sph005bak 150 "D:ftp s27_37_57-v100r006sph005bak.pat 226 Transfer finished successfully. Obtain the system software of the target version. [ftp] get S2700- V100R006C00SPC800.cc 200 PORT command successful 150 Opening BINARY mode data connection for FTP: 6502764 byte(s) received in 54.500 s original name is used. (Optional) Obtain the new c If the configuration file doe required. [ftp] get vrpcfgnew.zip 5. Close the FTP connection. [ftp] bye cify the system software in service, which is loaded when the S2700 is started. If the following information is displayed after you run the startup system-software file command, enter Y to update the BootROM. If the BootROM is upgraded successfully, go to step 8; otherwise, go to step Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y 7. BOOTROM begin to be upgraded ! please wait for a moment Info: BOOTROM UPGRADE OK Succeeded in setting the software for booting system.
  • 26. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 21 7. h is loaded when the S2700 is started. trom s2700-V100R006C00SPC800.cc Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y Upgrading BOOTROM,please wait for a moment [Slo Info (Optional) Upgrade the BootROM in service, whic <Quidway> system-view [Quidway] upgrade basic-boo t 0]: : BOOTROM UPGRADE OK. and V100R006, the BootROM is upgraded automatically. To upgrade the software to other versions, you must upgrade the BootROM manually. For details about automatic BootROM tep 6. In the case of a version rollback, you are advised to manually upgrade the BootROM to prevent a rollback failure. 8. Res In the V100R005 upgrade, see S tart the S2700. NOTE After the software is upgraded to V100R006C00SPC800, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to about specifying the system software for next startup, see step 6. guration, please wait. ved to the configuration file for the next startup:flash:/vrpcfg.zip, Continue?[Y/N]:y ng the current configuration to the slot 0. Info: Save the configuration successfully. System will reboot! Continue?[Y/N]: y Info: system is rebooting, please wait… 4.2 Upgrad Using the If the BootROM method is used, the services will be interrupted for a long time; therefore, you are advised to upgrade an operating device by using the command line. If the device cannot enter the command line mode, upgrade the device by using the BootROM. restart. For details When the system asks you whether to save the configuration, enter y or n. After the setting is complete, enter y to restart the system. <Quidway> reboot Info: The system is now comparing the confi Warning: All the configuration will be sa Now savi ----End ing the Switch to the V100R006C00SPC800 BootROM
  • 27. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 22 Figure 4-1 Flowchart for upgrading the version to the V100R006C00SPC800 using the BootROM End Start Upgrade BootROM See 4.2.1 Upload system software See 4.2.2 Specify startup software See 4.2.3 Restart the switch See 4.2.4 The methods for upgrading the system software using the BootROM are similar on the S2700, S3700, S5700 and the S6700. Here, the method for upgrading the system software on the S2700 is taken as an example. 4.2.1 Upgrading the BootROM Purpose To upgrade the BootROM Services are interrupted during the upgrade and the device reboot.Impact The upgrade takes about 100 seconds when the transmission rate of the serial interface is 115200 bit/s. Time Required After backing up the key data in the flash memory, you must run the reboot command in the user view to restart the system. Prerequisites Do not restart or power off the S2700 when the information "Update BOOTROM system…" is being displayed during the upgrade of the BootROM. Otherwise, the S2700 runs abnormally. In this case, contact Huawei technical personnel. You can restart or power off the S2700 only when the message "done!" is displayed.
  • 28. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 23 The BootROM menu varies according to the version. Here, the BootROM of V100R006C00SPC800 is taken as an example. 1. Use a serial cable to connect the serial interfaces on the PC and the S2700 and start the HyperTerminal on the PC. 2. Enter the connection name and click OK. 3. Select the serial interface and click OK. 4. On the COM Properties page, click Restore Defaults. Then set the value of Bits per second to 9600 and click OK. 5. If the prompt is displayed on the HyperTerminal, the HyperTerminal is connected to the S2700. In this case, you can upgrade the S2700 using the BootROM. 6. Enter the BootROM menu. Before entering the BootROM menu, you need to restart the S2700. During the restart of the S2700, the following information is displayed: Press Ctrl+B to enter BOOTROM menu... 1 Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei or www.huawei.com. Then the advanced BootROM menu is displayed. The following information is displayed: BOOTROM MENU 1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot Enter your choice(1-7): 7. Enter the BootROM submenu. Select 2. Enter serial submenu. The following information is displayed: SERIAL SUBMENU 1. Update BOOTROM system 2. Download file to Flash through serial interface 3. Modify serial interface parameter 4. Return to main menu 8. Modify the parameters of the serial interface.
  • 29. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 24 Changing the transmission rate of the serial interface causes interruption of the communication between the PC and S2700. To restore the communication between the PC and the S2700, you must set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700. Select 3. Modify serial interface parameter. The following information is displayed: Enter your choice(1-5): 3 1: 9600(default) 2: 19200 3: 38400 4: 57600 5: 115200 please select an appropriate baudrate: Enter your choice(1-5): Select the transmission rate for the serial interface as required. The transmission rate is expressed in bit/s. The default transmission rate of the serial interface on the S2700 is 9600 bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It is recommended that you enter 5: 115200. If you change the transmission rate of the serial interface on the S2700, set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700. In this manner, you can restore the communication between the PC and the S2700. For example, after you select 5: 115200, the following information is displayed: BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps In this case, you need to perform the following settings on the HyperTerminal of the PC to restore the communication between the PC and the S2700: On the HyperTerminal, choose Call > Disconnect. The connection is closed Choose File > Properties. The Properties dialog box is displayed. On the Connect To tab page, click Configure. The COM Properties dialog box is displayed. In the Bits per second drop-down list, select 115200. In the COM Properties and Properties dialog boxes, click OK. On the HyperTerminal, choose Call > Call. Press Enter. The connection is reestablished. 9. Upgrade the BootROM.
  • 30. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 25 The BootROMs for products of various series are incompatible with each other. For example, the BootROM of the S2700 cannot be used to upgrade the BootROM of the S3700; the BootROM of the S3700 cannot be used to upgrade the BootROM of the S2700. Select 1. Update BootROM system. The following information is displayed: Enter your choice(1-4): 1 Please Select File. XMODEM downloading ...CC Choose Transfer > Send File. The Send File dialog box is displayed. Click Browse. Then select the bootrom128.bin file for upgrading the BootROM. Ensure that the selected BootROM file corresponds to the product. Select XMODEM from the Protocol drop-down list box. Click Send to start sending the file. After the upgrade file is transferred, the following information is displayed: XMODEM downloading ...CC download to SDRAM successfully Warning: Don't Power-off or Reset the Device!!! Update bootrom system ... done ! Then, the S2700 automatically upgrades the BootROM by using the upgrade file. After the upgrade, the S2700 automatically returns to the BootROM menu. 10. After the BootROM is upgraded, restore the default rates of the serial interface and the HyperTerminal, and then reestablish the connection. Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and then select 7. Reboot to reboot the BootROM. ----End
  • 31. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 26 4.2.2 Uploading the System Software Uploading the System Software Through the Serial Interface Purpose To upgrade the system software Services are interrupted during the system software uploading and the device reboot. Impact The software uploading time depends on many factors, such as the system software size, transmission rate on the serial interface, and operator's skill. When the transmission rate of the serial interface is 115200 bit/s, the uploading time is about 30 minutes. Time Required Prerequisites The matched BootROM is upgraded. The flash memory has enough space to store the system software. 1. Enter the BootROM menu. When the S2700 is starting, the following information is displayed: Press Ctrl+B to enter BOOTROM menu... 1 Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei. Then the advanced BootROM menu is displayed. The following information is displayed: BOOTROM MENU 1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot Enter your choice(1-7): 2. Select 2. Enter serial submenu. The following information is displayed: SERIAL SUBMENU 1. Update BOOTROM system 2. Download file to Flash through serial interface 3. Modify serial interface parameter 4. Return to main menu Enter your choice(1-4):
  • 32. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 27 3. Modify the parameters of the serial interface. Changing the transmission rate of the serial interface causes interruption of the communication between the PC and S2700. To restore the communication between the PC and the S2700, you must set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700. Select 3. Modify serial interface boot parameter. The following information is displayed: 1: 9600(default) 2: 19200 3: 38400 4: 57600 5: 115200 please select an appropriate baudrate: Enter your choice(1-5): Select the transmission rate for the serial interface as required. The transmission rate is expressed in bit/s. The default transmission rate of the serial interface on the S2700 is 9600 bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It is recommended that you enter 5. 115200. If you change the transmission rate of the serial interface on the S2700, set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700. In this manner, you can restore the communication between the PC and the S2700. For example, after you select 5: 115200, the following information is displayed: BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps In this case, you need to perform the following settings on the HyperTerminal of the PC to restore the communication between the PC and the S2700: On the HyperTerminal, choose Call > Disconnect. The connection is closed Choose File > Properties. The Properties dialog box is displayed. On the Connect To tab page, click Configure. The COM Properties dialog box is displayed. Select 115200bit/s from the Bits per second drop-down list box. In the COM Properties and Properties dialog boxes, click OK. On the HyperTerminal, choose Call > Call. The connection is reestablished. 4. Upgrade the system software. Select 2. Download file to Flash through serial interface in the serial interface submenu, and the following information is displayed:
  • 33. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 28 Enter your choice(1-4): 2 Please Select File. XMODEM downloading ...CC Choose Transfer > Send File. The Send File dialog box is displayed. Click Browse to select the upgrade file of the system software. Then select Xmodem from the Protocol drop-down list box. Click Send to start sending the file. After transferring the upgrade file, the system prompts you whether to change the file name. If no, save it with the default file name. The default file name is not the uploaded file name. The system software name in the flash memory or the default file name hw-switch.cc is used. Generally, it is recommended that the file name be changed. Only the files with the file name extension .cc can be used as the upgrade files of the system software on the S2700. If you need to name the upgrade file S2700-V100R006C00SPC800.CC, the following information is displayed: XMODEM downloading ...CC download successfully! Do you like to save it named " S2700-V100R006C00SPC800.CC"? If you like then press return key, otherwise give a new name for saving it: S2700-V100R006C00SPC800.CC If the file S2700-V100R006C00SPC800.CC has already been saved in the flash memory, the system prompts you whether to overwrite the existing file with the new one. The following information is displayed: flash:/S2700-V100R006C00SPC800.CC already exist, delete it?(Y/N):y Deleting file.......................................done took time : 251s Writing Flash............................................................................. .................................................................................. ..............done file length: 6502764 bytes, took time : 144s SERIAL SUBMENU 1. Update BOOTROM system 2. Download file to Flash through serial interface 3. Modify serial interface parameter 4. Return to main menu Enter your choice(1-4): After the upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu. ----End
  • 34. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 29 Uploading the System Software Through the Network Port Purpose To upload the system software Services are interrupted during the system software uploading and the device reboot. Impact If the system software is uploaded through the FTP or TFTP protocol, the system software uploading time is about one minute. Time Required Prerequisites The matched BootROM is upgraded. The flash memory has enough space to store the system software. The FTP service is enabled on the PC. Pay attention to the following points: Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and then select 7. Reboot to reboot the BootROM. Enter the BootROM menu and load the system software. In addition, specify the software to be loaded in the startup. Upgrade the system software using the network interface in the BootROM menu. 1. Enter the BootROM menu. Before entering the BootROM menu, you need to restart the S2700. During the restart of the S2700, the following information is displayed: Press Ctrl+B to enter BOOTROM menu... 1 Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei. Then the advanced BootROM menu is displayed. The following information is displayed: BOOTROM MENU 1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot Enter your choice(1-7): 2. Select 4. Enter serial submenu. The following information is displayed: ETHERNET SUBMENU 1. Download file to SDRAM through ethernet interface and boot 2. Download file to Flash through ethernet interface 3. Modify ethernet interface boot parameter 4. Return to main menu Enter your choice(1-4):
  • 35. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 30 3. Modify the parameters of the network interface. Select 3. Modify ethernet interface boot parameter. The following information is displayed: BOOTLINE SUBMENU 1. Set TFTP protocol parameters 2. Set FTP protocol parameters 3. Return to ethernet menu Select TFTP or FTP as required. For example, the following information is displayed if you select 2. Set FTP protocol parameters. The displayed information cannot be cleared. New settings will overwrite the old settings. If the TFTP protocol is used, you do not need to enter the user name and password. '.' = clear field; '-' = go to previous field; ^D = quit Load File name : S2700-V100R006C00SPC800.CC Switch IP address : 192.168.1.15:FFFFFF00 Server IP address : 192.168.1.40 FTP User Name : cx FTP User Password : cx The fields are described as follows: Load File name: file name of the startup file to be loaded Switch IP address: device IP address (the mask is optional) Server IP address: server IP address FTP User Name: FTP user name FTP User Password: FTP password 4. Download the system software. After network interface parameters are modified, select 3. Return to ethernet menu to return to the Ethernet submenu. Connect the data line to port 1 on the S2700 panel (or connect the data line to the MEth interface of the S5700), and then select 2. Download file to Flash through ethernet interface to load the file. The following information is displayed: '.' = clear field; '-' = go to previous field; ^D = quit boot device : et unit number : 0 processor number : 0 host name : host file name : S2700-V100R006C00SPC800.CC inet on ethernet (e) : 192.168.1.15:FFFFFF00 host inet (h) : 192.168.1.40 user (u) : cx ftp password (pw) : cx flags (f) : 0x0
  • 36. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 31 Attached TCP/IP interface to mottsec0. Attaching network interface lo0... done. Loading... Read file to sdram .......Done Writing Flash............................................................................. ..................done File length: 6502764 bytes Took time : 33s After the upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu. ----End 4.2.3 Specifying the System Software to Be Loaded for Starting the Switch Purpose To specify the system software for next startup Services are interrupted when you are specifying the system software and the device is restarting. Impact The system software to be specified has been downloaded to the flash memory. Prerequisite 1. Specify the system software to be loaded for starting the switch. After returning to the BootROM menu, select 3. Enter startup submenu to enter the startup submenu. The following information is displayed: Startup Configuration Submenu 1. Display startup configuration 2. Modify startup configuration 3. Return to main menu Enter your choice(1-3): 2. Select 2. Modify startup configuration to set the startup mode of the S2700, system software, configuration file, license file, and patch file. The following information is displayed: Note: startup file field cannot be cleared '.'=clear field; '^D'=quit; Enter=use current configuration startup type(1: Flash 2: Server) current: 1 new : 1
  • 37. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 32 Flash startup file (cannot be cleared) current: new : S2700-V100R006C00SPC800.CC saved-configuration file current: vrpcfg.zip new : license file current: new : patch package current: new : Table 4-1 describes the displayed information. Table 4-1 Description of the displayed information Field Description startup type Startup mode: 1: loads the system software from the flash memory. 2: loads the system software from the server. Flash startup file System software loaded during the startup. If the system software is loaded from the server, you do not need to set the field. saved-configuration file Configuration file loaded during startup. patch package Patch file loaded during startup. current File that is currently loaded. new File to be loaded during the next startup. Startup Configuration Submenu 1. Display startup configuration 2. Modify startup configuration 3. Return to main menu Enter your choice(1-3): 3. After entering the startup information, select 3. Return to main menu to return to the BootROM menu. BOOTROM MENU 1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu
  • 38. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 33 6. Modify BOOTROM password 7. Reboot Enter your choice(1-7): ----End 4.2.4 Restarting the Switch The switch is automatically upgraded by loading the latest system software during startup. Enter 7. Reboot on the advanced BootROM menu to restart the switch. Then, the S2700 restores the baud rate on the console interface to 9600 bit/s. The baud rate of the HyperTerminal also needs to be set to 9600 bit/s. The PC then can communicate with the S2700. 4.3 Upgrading the S5700-SI to V100R006C00SPC800 Using the USB Flash Drive 4.3.1 Overview If you do not have a PC in the on-site deployment, use the USB flash drive in which the system software and configuration file are stored. The software commissioning engineer is not required. Only the S5700-SI and S6700 can be upgraded using the USB flash drive. Stacks do not support this upgrade method. The general process of the upgrade in the USB way is as follows: a. Copy files. When the S5700-SI is started successfully (the SYS indicator is in green and blinks at 0.5 Hz), the USB flash drive can be inserted to load files. The S5700-SI automatically downloads the system software and configuration file according to the index file in the USB flash drive. b. Restart the switch. The S5700-SI sets the system software and configuration file for next startup, and then restarts automatically. c. Verify the loading of files. After restarting successfully (the SYS indicator is in green and blinks at 0.5 Hz), the S5700-SI begins to verify the loaded files. When the SYS indicator is in orange and blinks at 0.5 Hz, the upgrade is finished.
  • 39. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 34 4.3.2 Upgrading the Software Using the USB Flash Drive Preparations for Upgrade 1. Prepare the hardware. USB port: The S5700-SI provide USB 1.1; the S6700 provide USB 2.0. USB flash drive: The USB flash drive delivered with Huawei switch is recommended because this USB flash drive is compatible with the switch. The USB flash drive must be paid independently. If you have not bought the USB flash drive, contact local Huawei office. The USB flash drive must use the FAT32 format; otherwise, set the format to FAT32 before using it. The space in the USB flash drive must be sufficient for the system software and configuration file. 2. Prepare system software, configuration file, web file, and patch file. 3. Create the index file. a. Create the file usbload_config.txt. b. Fill in the file. If you need to upgrade the system software, configuration file or patch file of V100R006, the index file is in any of the following formats: <sn=201105091219;/> <mac=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/> <esn=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/> <boardtype=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/> The first line in the index file must be the SN to prevent repeated copy. The SN consists of creation date + time, for example, <sn=201105091219;/>. Before copying a file, the device compares the SNs. If the SN of a file to be copied already exists, the device does not copy the file. After the file is copied, the device stores the SN. The index files without SNs are considered invalid, and the device will stop copying the files. If an index file contains the following three formats, the device uses the information in format (2). If the required information is not obtained, the device uses the information in format (3) and then format (1). When only one USB flash drive is used in the upgrade, the values of mac=, esn=, and boardtype= are default. When the device obtains the value default, the device starts to copy the file without comparing it with other files. When editing an index file, press Enter when a line is finished. After editing the file, save it. Select the upgrade files, including system software, configuration file, Web file, and patch file as required. The upgrade procedures for S5700-SI, and S6700 are the same. (1) To upgrade the same system software, configuration file, Web file, and patch file on multiple devices, fill in the file in the format <boardtype=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/>.
  • 40. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 35 − To obtain the value of boardtype, view device labels or run the display version command. boardtype=default indicates that all devices will be upgraded. − Fill in the system software name behind vrpfile=. − Fill in the version number behind vrpfile=. − Fill in the configuration file name behind cfgfile=. − Fill in the web file name behind webfile=. − Fill in the patch file name behind patchfile=. The following are the index files of different devices: <boardtype=S5728C-SI; vrpfile=S5700SI-V100R006C00SPC800.CC; vrpver=V100R006C00SPC800; cfgfile=; webfile=; patchfile=;/> <boardtype=S6748-EI; vrpfile=S6700-V100R006C00SPC800.CC; vrpver=V100R006C00SPC800; cfgfile=; webfile=; patchfile=;/> The following two formats are used for upgrading a single device: (2) <mac=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/> − View the device's MAC address on the chassis and fill in the MAC address behind mac= in the format XXXX-XXXX-XXXX. − Fill in the system software name behind vrpfile=. − Fill in the version number behind vrpfile=. − Fill in the configuration file name behind cfgfile=. − Fill in the web file name behind webfile=. − Fill in the patch file name behind patchfile=. The following is an example of configuration file: <mac=0018-8200-0001; vrpfile=; vrpver=; cfgfile=vrpcfg.cfg; webfile=; patchfile=;/> The following is an example of patch file: <mac=0018-8200-0002; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=patch.pat;/> (3) <esn=; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=;/> − View the device's ESN and fill in the ESN behind esn=. − Fill in the system software name behind vrpfile=. − Fill in the version number behind vrpfile=. − Fill in the configuration file name behind cfgfile=. − Fill in the web file name behind webfile=. − Fill in the patch file name behind patchfile=. The following is an example of patch file: <esn=020TEA10A9000016; vrpfile=; vrpver=; cfgfile=; webfile=; patchfile=patch.pat;/>
  • 41. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 36 The following is an example of system software: <esn=020TEA10A9000017; vrpfile=S5700SI-V100R006C00SPC800.CC; vrpver=V100R006C00SPC800; cfgfile=vrpcfg.cfg; webfile=; patchfile=;/> If a keyword is not found or matched, the value of this item is considered to be empty. If the version number behind vrpver= is the same as the current version, the device will not restart. 4. Copy the index file, system software, configuration file, Web file, and patch file to the root directory of the USB flash drive. The index files must be stored to the root directory on the USB flash drive; the other files are stored in the corresponding directories. Do not power off the switch during file copy; otherwise, the upgrade fails or the switch cannot start. Do not remove the USB flash drive before the upgrade is finished; otherwise, the USB flash drive may be damaged. Procedure 1. Power on the S5700-SI, and wait until the system completes the startup (you are advertised to wait for two minutes). 2. Confirm that the system is operating stably (the SYS indicator is in green and blinks every two seconds). If the system operating is unstable, wait or solve the issue. If the SYS indicator is on and in green or orange, the system startup is not finished. Wait until the system starts successfully. If the SYS indicator is on and in red, the system is started but an error occurs. Fix the problem before the next step. Check whether the power supply and the fan function properly. If no, power off the S5700-SI, and then restart the S5700-SI. If the fault persists (the indicator is on and in red), contact Huawei technical support personnel. 3. Insert the USB flash drive. If the SYS indicator is in green and blinks more than twice every second, the system is copying the system software and configuration file from the USB flash drive. After copying the files, the system restarts. If the SYS indicator is in orange and blinks every two seconds after the restart, the upgrade is successful. Now you can remove the USB flash drive.
  • 42. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 37 If the SYS indicator is on or blinks in red, or blinks and is in read, an error occurs. Power off the S5700-SI and power on it, and then insert the USB flash drive again. If the upgrade fails three times, check whether the index file on the USB flash drive is correct, or contact the Huawei technical support personnel. NOTE When using the USB flash drive for upgrade, change the SN in the USB flash drive. ----End
  • 43. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 38 5 Upgrade Operations on a Stack 5.1 Upgrading All Stack Member Switches to V100R006C00SPC800 by Using the Command Line To upgrade the system softwarePurpose Services are interrupted when the devices restart.Impact When a single device is upgraded and service deployment is simple, stack is upgraded, theservices are interrupted about 3 minutes. When a Time Required service interruption time increases, and the time depends on the complexity of services and the stack. Prerequisites The devices to be upgraded function properly. The flash memory has enough space to store the system software.
  • 44. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 39 The methods of for upgrading the system software of the S3700, S5700 and the S6700 using the command line interface are similar. Here, the S3700 is used as an example. the system software by using the S3700 as the FTP server. For other methods of loading the system software, see the Quidway S3700/S5700/S6700 ns. retain the roles of the master and slave devices after the upgrade, set priority of the master switch The section describes only how to download Series Ethernet Switches Configuration Guide - Basic Configuratio The S5700/S6700 provides a management interface MEth. You can use this interface as a Layer 3 interface. To to be the highest in the stack before the upgrade. When an S3700 is upgraded to V100R006C00SPC800, you must delete the startup file because the flash memory space is limited. The following operations are performed on the master switch. Here, the stack contains two 1. te /unreserved flash:/S3752-V100R006C00.cc tware. If you delete it, there is no software to e the file? [Y/N]:y Warning: The contents of file flash:/S3752-V100R006C00.cc cannot be recycled. Continue? eting file flash:/S3752-V100R006C00.cc... Deleting file permanently from flash will take a long time if ........................................................... ..................................................... .......................................succeeded. 0R006C00.cc e it, there is no software to nfirm to delete the file? [Y/N]:y flash:/S3752-V100R006C00.cc cannot be recycled. 2. as the FTP server. and set the FTP user name to ftpuser and password to tp server enable member switches. Delete the current startup software package. <Quidway> dele Info:This is Next startup system sof reboot successfully!Confirm to delet [Y/N]:y Info: Del needed................. ............................. ............... <Quidway> delete /unreserved slot1#flash:/S3752-V10 Info:This is Next startup system software. If you delet reboot successfully!Co Warning: The contents of file slot1# Continue? [Y/N]:y Info: Deleting file slot1#flash:/S3752-V100R006C00.cc... Deleting file permanently from flash will take a long time if needed............................................................................ .................................................................................. .................................................................................. ..succeeded. Configure the switch Start the FTP service on the switch, ftppwd. <Quidway> system-view [Quidway] f
  • 45. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 40 [Quidway] aaa [Quidway-aaa] local-user ftpuser password simple ftppwd local-user ftpuser service-type ftp [Qui flash: [Quidway-aaa] return 3. n an idle interface. Here, ethernet 0/0/1 is used as an example. view rnet 0/0/1 an10] port ethernet 0/0/1 y] interface vlanif 10 [Quidway] 4. [Quidway-aaa] dway-aaa] local-user ftpuser ftp-directory Configure an IP address for the switch. Configure the IP address o <Quidway> system- [Quidway]interface Ethe [Quidway-Ethernet0/0/1]port link-type access [Quidway-Ethernet0/0/1]quit [Quidway] vlan 10 [Quidway-vl [Quidway-vlan10] quit [Quidwa [Quidway-Vlanif10] ip address 1.1.1.1 24 [Quidway-Vlanif10] quit Log in to the FTP server (the switch). Assume that the Windows XP operating system is used. . Choose d press Enter. Enter FTP 1.1.1.1. Enter the user name at the user nter. The following n is displayed: >ftp 1.1.1.1 ted to 1.1.1.1. 220 FTP service ready. 331 Password required for 1. 230 User logged in. ftp> 5. Uploa the switch. the FTP client to upload m software is uploaded to the switch, run the bye command to 2-V100R006C00SPC800.CC -V100R006C00SPC800.CC. s sent in 60.40Seconds 140.76Kbytes/sec. ftp> bye 221 Server closing. D:> Store the file to be uploaded in the specified directory (for example, D:>directory) Start > Run. Enter cmd an prompt and the password at the password prompt, and then press E informatio D: Connec User (1.1.1.2:(none)): ftpuser Password: d the system software to Run the put source-filename [ destination-filename ] command on the system software. After syste close the FTP connection and return to the user view. ftp> put D:S375 200 Port command okay. 150 Opening BINARY mode data connection for S3752 226 Transfer complete. ftp: 8742812 byte
  • 46. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 41 6. Specify th uploaded software as the next startup software. <Qui e dway> startup system-software S3752-V100R006C00SPC800.CC all If the following information is displayed after you run the startup system-software file command, enter y to upgrade the BootROM. Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y e upgraded ! please wait for a moment ooting system on 0. C800.cc to booting system on 1. 7. BOOTROM begin to b Info: BOOTROM UPGRADE OK Info: Succeeded in setting the software for b 100% complete Info: Copied file flash:/S3752-V100R006C00SP slot1#flash:/S3752-V100R006C00SPC800.cc...Done. Info: Succeeded in setting the software for Restart the switch. After the software is upgraded to V100R006C00SPC800, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to restart. For details about specifying the system software for next startup, see step 5. When the system asks you whether to save the configuration, enter y or n. After the setting is Info: The system is now comparing the configuration, please wait. g: All the configuration will be saved to the configuration file for the next p:flash:/vrpcfg.zip, Continue?[Y/N]:y Now saving the current configuration to the slot 0. Info: Save the configuration successfully. ----E 5.2 Using the Intelligent Upgrade Function 5.2.1 Overview el rades or rolls back the system software of a new itch. complete, enter y to restart the system. <Quidway> reboot Warnin startu Info: Save the configuration successfully. Now saving the current configuration to the slot 1. System will reboot! Continue?[Y/N]: y Info: system is rebooting, please wait… nd Int ligent upgrade is a function that automatically upg member switch to the version of the master sw A stack system is established only when all the following requirements are met:
  • 47. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 42 All the member switches use the same software version. If the master switch detec different software version on the new member switch, it upgrades or rolls back the software of ts a the new member switch to the version of the stack. ports a maximum of eight switches in a stack system. The other S3700 models and the up to nine switches in a stack system. s ing function is enabled on all the member switches. he stack processes version upgrade and rollback for new member switches in the same way. 5.2.2 Upgrading a N ber Switch Using the Intelligent Upgrade Function Preparations for Be nnected to other member switches by using stack cables bled by The S3752 sup S5700 support The S3752 and S3728 cannot be added to the same stack system. All the member switches belong to the same series. That is, the EI series and SI serie cannot form a stack. All the member switches are connected by using stack cables and stack modules. All the member switches are working properly. The stack T ew Mem Upgrade fore upgrading a new member switch of a stack, ensure that: The new member switch and the current stack members belong to the same series. The new member switch is co and stack modules. The stacking function is enabled on the new member switch. (This function is ena default.)
  • 48. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 43 If the flash memory of the new member switch does not have sufficient space to store the startup software package, the switch automatically deletes a software package to free up tch is an S5700, it deletes a non-startup software package. If the switch is an S3700, it deletes the current startup software package. If the available space in the switch restarts repeatedly. In this case, upgrade the software of the switch to the version of the stack system manually, re, see chapter 4 Upgrade itch. During the upgrade, ensure that the stack cables are functioning properly. If the upgrade of the space. If the swi flash memory is still insufficient for the upgrade software, the and then add the switch to the stack. For the upgrade procedu Operations on a Single Sw a switch fails, upgrade the system software of the switch to the version of the stack manually, and then add the switch to the stack. Upgrade Process On the master switch: In Stack, device 0 load to new device 1 .......... start In Stack, device 0 load to new device 1 .......... success On the new member switch: The Software Version is Low.Version is V100R006C00! 100% completed In Stack, device 0 load flash:/S5700EI-V100R006C00SPC800.CC to new device 1(self) ... Success Starting upgrade BOOTROM .............. Pass Device starting reset. If the flash memory of the new member switch does not have sufficient space for the upgrade software, the following information is displayed: On the master switch: In Stack, device 0 load to new device 1 .......... start In Stack, device 0 load to new device 1 .......... fail On the new member switch: In Stack, upgrading from slot 4 to slot 0(self) .......... start Info: Free space is not enough. Auto deleting <flash:/S3728-V100R006C00.cc> file .... Start the new member switch. The master switch of the stack automatically upgrades the new switch. If the upgrade is successful, the following information will be displayed:
  • 49. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 44 ................................................................................ ........................... success 100% completed In Stack, device 4 load to new device 0 (self) ... Success Upgrading BOOTROM .............. Pass Manually upgrade the system softw then add the switch to the stack syst V100R006C00SPC800 Using the Co V100R006C00SPC800 Using the BootROM. are of the switch to the version of the stack system, and em. For details, see sections 4.1 Upgrading the Switch to mmand Line or 4.2 Upgrading the Switch to the
  • 50. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 6 Verifying the Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 45 6 Verifying the Upgrade 6.1 Verification Checklist Table 6-1 Verification checklist No. Item Criteria Result 1 Check the current system The system software version software version is V100R006C00SPC800. 2 Check the device running The device runs properly. status 3 Check the system The system configuration is configuration correct. 6.2 Checking the Current System Software Version nning on the s 4M bytes DDR Memory Pcb Version : VER C Basic BOOTROM Version : 124 Compiled at Apr 20 2011, 10:04:52 Run the display version command to view the version of the system software ru S2700. <Quidway> display version Huawei Versatile Routing Platform Software VRP (R) software, Version 5.70 (S2700 V100R006C00SPC800) Copyright (C) 2003-2011 HUAWEI TECH CO., LTD Quidway S2718TP-SI Routing Switch uptime is 0 week, 0 day, 0 hour, 4 minute EDFE 0(Master) : uptime is 0 week, 0 day, 0 hour, 4 minutes 6 16M bytes FLASH
  • 51. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 6 Verifying the Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 46 Software Version : VRP (R) Software, Version 5.70 (S2700 V100R006C00SPC800) 6.3 Checking the Device Running Status Run the display device command to check the s the device functions properly. <Quidway> display device S2718TP-SI's Device status: Slot Sub Type Online Power Register Status Role - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0 - 2718F Present PowerOn Registered Normal Master 6.4 Checking the System Configuration Use the display current-configuration command to check the system configuration. Check V100R006C00SPC800 (V100R006C00SPC800 is n number depends on the released version) and e following configuration is taken as an example). d after the upgrade. For the command line changes, see the release notes of the matching version. authorization-scheme default ccounting-scheme default omain default domain default_admin local-user admin password simple admin local-user admin service-type http # witch running status. Normal indicates that whether the system software version is taken as an example and the actual versio whether the configuration is restored (th The configuration file may be modifie <Quidway>display current-configuration # !Software Version V100R006C00SPC800 sysname Quidway # vlan batch 1 # cluster enable ntdp enable ntdp hop 16 ndp enable # dhcp enable # undo http server enable # drop illegal-mac alarm # aaa authentication-scheme default a d
  • 52. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 6 Verifying the Upgrade Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 47
  • 53. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 7 Version Rollback Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 48 7 Version Rollback 7.1 S2700 Version Rollback If an error occurs after the upgrade, perfor operating. Rollback Flowchart m version rollback to restore normal service 7.1.1 Version Figure 7-1 Version rollback flowchart End Start Load previous softwar See 7.1.2 e package Perform version rollback See 7.1.3 Verify version rollback See 7.1.4
  • 54. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 7 Version Rollback Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 49 1. Only the configuration file in cfg format can be used for rollback. Before performing version rollback, check the format of the configuration file. If the configuration file is not in elete files stored in the flash memory before the device is rolled back from V100R006SPC500 to V100R006, some space in the flash memory may be d cfg format, save it in the cfg format. 2. If you run the delete command to d unavailable. Run the dir command to view the unknown space and run the fixdisk comman to reclaim the space. 7.1.2 Loading the Previous System Software vious system software package is the same as the procedure For details, see chapter 4 Upgrade Operations 7.1.3 Perform as the version upgrade method. For details, see Switch. 7.1.4 Verifyi same as the verification of version upgrade. For e. The procedure for loading the pre for loading the system software for the upgrade. on a Single Switch. ing Version Rollback The version rollback method is the same chapter 4 Upgrade Operations on a Single ng Version Rollback The verification of version rollback is the details, see chapter 6 Verifying the Upgrad
  • 55. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 7 Version Rollback Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 50 7.2 S3700 Version Rollback 7.2.1 Version Rollback Flowchart Figure 7-2 Version rollback flowchart Start Load previous software package See 7.2.2 Perform version rollback See 7.2.3 Verify version rollback See 7.2.4 End 1. When the S3728 V100R006C00SPC800 is rolled back to the S3728 V100R006C00, the 2. Only the configuration file in cfg format can be used for rollback. Before performing version rollback, check the format of the configuration file. If the configuration file is not in cfg format, save it in the cfg format. 3. If you run the delete command to delete files stored in the flash memory before the device is rolled back from V100R006SPC500 to V100R006, some space in the flash memory may be unavailable. Run the dir command to view the unknown space and run the fixdisk command output information may be different from the normal output information displayed during upgrade. to reclaim the space. 7.2.2 Loading the Previous System Software The procedure for loading the previous system software package is the same as the procedure for loading the system software for the upgrade. For details, see chapters 4 Upgrade Operations on a Single Switch or 5 Upgrade Operations on a Stack.
  • 56. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 7 Version Rollback Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 51 7.2.3 Performing Version Rollback The version rollback method is the same as the version upgrade method. For details, see chapters X4 XXUpgrade Operations on a Single SwitchX or X5 XXUpgrade Operations on a StackX. 7.2.4 Verifying Version Rollback The verification of version rollback is the same as the verification of version upgrade. For details, see chapter X6 XXVerifying the UpgradeX. 7.3 S5700 Version Rollback 7.3.1 Version Rollback Flowchart Figure 7-3 Version rollback flowchart End Start Load previous software package See 7.3.2 Perform version rollback See 7.3.3 Verify version rollback See 7.3.4
  • 57. Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 7 Version Rollback Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd 52 When the S5700 V100R006C00SPC800 is rolled back to the S5700 V100R006, pay attention to the following point: Only the configuration file in cfg format can be used for rollback. Before performing version rollback, check the format of the configuration file. If the configuration file is not in cfg format, save it in the cfg format. BootROM cannot be used for version rollback on the S5700SI, and the S5700SI cannot be powered off during a version rollback. If you run the delete command to delete files stored in the flash memory before the device is rolled back from V100R006SPC500 to V100R006, some space in the flash memory may be unavailable. Run the dir command to view the unknown space and run the fixdisk command to reclaim the space. 7.3.2 Loading the Previous System Software The procedure for loading the previous system software package is the same as the procedure for loading the system software for the upgrade. For details, see chapters X4 XXUpgrade Operations on a Single SwitchX or X5 XXUpgrade Operations on a StackX. 7.3.3 Performing Version Rollback The version rollback method is the same as the version upgrade method. For details, see chapters X4 XXUpgrade Operations on a Single SwitchX or X5 XXUpgrade Operations on a StackX. 7.3.4 Verifying Version Rollback The verification of version rollback is the same as the verification of version upgrade. For details, see chapter X6 XXVerifying the UpgradeX.