1. Fabric Content: 100% Nomex 111A Fiber
Performance Measure CXP Traditional Nomex Test / Standard
Weight 4.5 oz / 6.0 oz
Arc Thermal Protection Value – 6.5 5.7 NFPA 1506 Arc
For Heat Resistance Thermal
Protective Value
Flame Resistance NFPA 701-89
After Glow <1 sec <1 sec Flammability
After Flame <1 sec <1 sec
Char Length 2.3” 3.8”
Flame Resistance 22% 35% NFPA 2112 – 3
Second Body Burn Test Second Body
Burn Test
Sunlight Fade Resistance 4.0 2.5 AATCC 16
Air Permeability 78 47 ASTM D 737-96
Moisture Management (inches 6.8” 4.6”
wicked in 1 minute)
ASTM – American Standard for Testing Materials
NFPA – National Fire Protection Agency
Standards met by Fabric:
• NFPA 2112 – Standard on Flame-Resistant Garments for Protection of Industrial
Personnel against Flash Fire specifies the minimum performance requirements and test
methods for flame-resistant fabrics and components and the design and certification
requirements for garments for use in areas at risk from flash fires