Helios is a leading manufacturer of telecom equipment in China, founded in 1994. It has a large R&D team focused on analog and digital RF technologies. Helios produces a range of wireless network optimization solutions including residential and pico repeaters to expand network coverage. Their repeaters use innovative digital and SDR technologies allowing flexible bandwidth adjustment and upgrading without hardware changes. Helios has passed key certifications and sells products to over 30 international operators worldwide.
Measuring Fiber / Merenja na optičkim vlaknimaNemanja Radić
1. Fiber optic networks are constantly increasing in speed and capacity to meet new application demands like interactive video.
2. Standards like ANSI/TIA-568-C set allowable loss limits for fiber optic links based on factors like cable length, number of splices and adapters.
3. Proper cleaning, inspection and testing of fiber optic connections and links is important to ensure low loss and good performance. A visual fault locator can be used to check basic connectivity but more advanced testing may be required.
EKSPERIMENTALNI REZULTATI MJERENJA ODZIVA NAMOTAJA TRANSFORMATORA PRI OSCILAT...Juso Ikanovic
U ovom radu ukratko је dat koncept konзtruktivnog rjesenja autotransformatora
tip ART бо/2о/4о MVA 22о/132 +- 8х1,25% / ЗЗ +- 8х1,25% kV proizvodnje
Energoinvest - Cгnuce. U toku pгoizvodnje i na zavrsenim transformatorima
izvгseno је niz mjeгenja, а роsеbnа paznja posvecena је гaspodjeli napona ро
namotajima tгansfoгmatora. Ovdje su dati neki od rezultata mjerenja pri oscilatornom
i apeгiodicnom niskonaponskom pobudivanju na izvodima transformatora.
Helios is a leading manufacturer of telecom equipment in China, founded in 1994. It has a large R&D team focused on analog and digital RF technologies. Helios produces a range of wireless network optimization solutions including residential and pico repeaters to expand network coverage. Their repeaters use innovative digital and SDR technologies allowing flexible bandwidth adjustment and upgrading without hardware changes. Helios has passed key certifications and sells products to over 30 international operators worldwide.
Measuring Fiber / Merenja na optičkim vlaknimaNemanja Radić
1. Fiber optic networks are constantly increasing in speed and capacity to meet new application demands like interactive video.
2. Standards like ANSI/TIA-568-C set allowable loss limits for fiber optic links based on factors like cable length, number of splices and adapters.
3. Proper cleaning, inspection and testing of fiber optic connections and links is important to ensure low loss and good performance. A visual fault locator can be used to check basic connectivity but more advanced testing may be required.
EKSPERIMENTALNI REZULTATI MJERENJA ODZIVA NAMOTAJA TRANSFORMATORA PRI OSCILAT...Juso Ikanovic
U ovom radu ukratko је dat koncept konзtruktivnog rjesenja autotransformatora
tip ART бо/2о/4о MVA 22о/132 +- 8х1,25% / ЗЗ +- 8х1,25% kV proizvodnje
Energoinvest - Cгnuce. U toku pгoizvodnje i na zavrsenim transformatorima
izvгseno је niz mjeгenja, а роsеbnа paznja posvecena је гaspodjeli napona ро
namotajima tгansfoгmatora. Ovdje su dati neki od rezultata mjerenja pri oscilatornom
i apeгiodicnom niskonaponskom pobudivanju na izvodima transformatora.
3. Standardi: ETHERNET OVER TWISTED PAIR
COPPER MEASURING
• IEEE – Institute of Electrical and Electronics Engineers
• Prve verzije standarda – ’80 godina
• XBASE-T(X) – Aplikativni standard koji koristi upredene parice na fizičkom sloju
Ethernet kompjuterske mreţe
• Drugi standardi u ovu svrhu koriste koaksijalni kabl ili optičko vlakno
• Trenutno najviše korišćeni – 100BASE-TX i 1000BASE-T
4. Standardi: ETHERNET OVER TWISTED PAIR
Brzina Dužina
[Mbit/s] [m]
Ime
Standard
/ Godina
1
100
StarLAN
802.3e
1986
10
100
LattisNet
COPPER MEASURING
Opis
Dve upredene parice (telefonske upredene parice ili Cat3 kabl)
Mančester kodiranje
(pre) 802.3i Za potrebe AT&T Premises Distribution System (PDS) ožičenja
1987
Dve upredene parice (telefonske upredene parice ili Cat3 kabl)
10
100 10BASE-T
802.3i
1990
Dve upredene parice (Cat 3 ili Cat5 kabl)
Topologija zvezde - akivan hub ili switch u sredini sa portom za svaki nod
Mančester kodiranje; Dva nivoa: +2.5V i -2.5V
Ista konfiguracija se koristi za 100BASE-T i Gigabit Ethernet (osetljiviji na
kvalitet kabla)
100
100 100BASE-TX
802.3u
1995
Dve upredene parice (Cat5 kabl)
4B5B MLT-3 kodiranje; Tri nivoa: +1V, 0V i −1V
1000
100 1000BASE-T
802.3ab
1999
Četiri upredene parice (minimum Cat5 kabl)
Svaka parica se koristi za komunikaciju u oba smera simultano
PAM-5 kodiranje; Pet nivoa: −2V, −1V, 0V, +1V i +2V
10 000
100 10GBASE-T
802.3an
2006
Četiri balansirane upredene parice (Cat 6a kabl)
THP PAM-16 kodiranje
40 000
≥30 40GBASE-T
802.3bq
U razvoju
10GBASE-T kodiranje preko Cat8.1/8.2 kablova sa plaštom
100G u razvoju – data centri
5. Standardi: ISTORIJA
COPPER MEASURING
• Prvobitni standardi su karakterisali ţilu i komponente kabla.
• 1995. prvi standard koji definiše kabl u celosti (TIA/EIA-568-A i TSB67).
• Danas: ISO/IEC 11801, EN 50173 i TIA/EIA-568.
ISO/IEC Cable Grade
Operating Frequency
TIA/EIA Cable Grade
Operating Frequency
Class A
Up to 100KHz
—
—
Class B
Up to 1MHz
—
—
Class C
Up to 16MHz
Category 3
Up to 16MHz
Class D
Up to 100MHz
Category 5e
Up to 100MHz
Class E
Up to 250MHz
Category 6
Up to 250MHz
Class EA
Up to 500MHz
Category 6A
Up to 500MHz
Class F
Up to 600MHz
—
—
Class FA
Up to 1000MHz
—
—
Class I
Between 1.6GHz – 2.0GHz
Category 8.1
Between 1.6GHz – 2.0GHz
Class II
Between 1.6GHz – 2.0GHz
Category 8.2
Between 1.6GHz – 2.0GHz
6. Standardi: EVOLUCIJA
COPPER MEASURING
TIA/EIA-568-A
TIA/EIA-568-B
TIA/EIA-568-C
TSB67
TSB95
Addendum 5
TIA/EIA-568-B.2-1
TIA/EIA-568-C.2
"Old" Cat 5
"New" Cat 5
Cat 5e
Cat 6
Cat 6A
Frequency Range
1–100MHz
1–100MHz
1–100MHz
1–250MHz
1–500MHz
Propagation Delay
Not Specified
Specified
Same as TSB95
Same as TSB95
Same as TSB95
Delay Skew
Not Specified
Specified
Same as TSB95
Same as TSB95
Same as TSB95
Attenuation
Specified
Same as Cat 5
Same as Cat 5
43 percent better
43 percent better
NEXT
Specified
Same as Cat 5
41 percent better
337 percent better
337 percent better
PS NEXT
Not Specified
Not Specified
Specified
216 percent better
216 percent better
ELFEXT
Not Specified
Specified
5 percent better
104 percent better
104 percent better
PS ELFEXT
Not Specified
Specified
Same as TSB95
95 percent better
95 percent better
Return Loss
Not Specified
Specified
26 percent better
58 percent better
58 percent better
10. WIREMAP
COPPER MEASURING
Pre frekvencijskih testiranja link mora biti
verifikovan sa jednostavnim pin-to-pin
proverama kako bi se osigurao:
•
Kontinuitet do udaljenog kraja
•
Spojevi izmeĎu dva ili više provodnika
•
Zamenjene parice
•
Parice u prekidu
•
Premeštene parice
•
Drugi problemi
11. REVERSED PAIR ZAMENJENE ŢICE
SHORT OR OPEN KRATKA ŢICA ILI BEZ SPOJA
• Parica 2 – zamenjene ţice
COPPER MEASURING
• Parica 1 – bez spoja
• Parica 2 – kratak spoj
12. SPLIT PAIR RAZDVOJENE PARICE
COPPER MEASURING
• Iz pojedinačnih ţica dva različita
para formira se novi par.
• Preslušavanje u novonastalom paru.
• Iako će ova greška dati dobre
rezultate prilikom merenja oţičenja
(pin-to-pin), greške prilikom prenosa
su neminovne.
• Testeri kablova ne mogu detektovati
razdvojene parice ali, uz pomoć
merenja NEXT (Near End CrossTalk)
i izuzetno loših rezultata tog merenja
moţe se predpostaviti da se radi o
grešci ovog tipa.
13. PROPAGATION DELAY
KAŠNJENJE USLED PROPAGACIJE
COPPER MEASURING
• Električni signal putuje istom brzinom kroz ceo kabl. Parametar kojim se
opisuje ova karakteristika se naziva nominalna brzina propagacije –
NVP.
• NVP prikazuje brzinu kojom signal putuje kroz kabl u odnosu na brzinu
svetla, iskazano u procentima.
• Brzina kojom signal putuje iznosi 60%-80% brzine svetla, otprilike 20cm
u jednoj nanosekundi.
• Najveći uticaj na ovu brzinu ima materijal kojim je izraĎena izolacija.
14. DELAY SKEW
KAŠNJENJE IZMEĐU PARICA
•
•
•
•
•
COPPER MEASURING
Prikaz razlike kašnjenja usled propagacije
izmeĎu svake parice.
Parice sa najmanjom i najvećom
propagacijom se uzimaju kao ekstremi.
Idealne vrednosti ovog parametra su izmeĎu
25ns i 50ns gledano na 100m kabla.
Uvedeno zbog korišćenja različite izolacije
za različite parice (u formi 2+2 ili 3+1) i time
uvelo značajan uticaj na NVP parametar
kabla.
Kritično merenje za 1000BASET, 10GBASE-T ili bilo koju drugu
implementaciju gde se koriste višestruke
parice za simultani prenos u istom
smeru, kako ne bi došlo do „klizanja“ meĎu
vremenskim slotovima na prijemniku.
15. LENGTH DUŢINA
COPPER MEASURING
• Merenje duţine kabla/parice se radi uz pomoć TDR (Time Domain
Reflectometry) testa.
• Ukratko, merni instrument šalje puls u svaku paricu i meri vreme koje je
potrebno pulsu da se vrati kroz istu paricu i na osnovu tok vremena
kalkuliše duţinu.
• Kada god puls naiĎe na varijaciju impedanse (loša konekcija, otvoreno
kolo, kratak spoj...) deo pulsa se reflektuje nazad u tester.
• Veličina povratnog pulsa je proporcionalna sa promenom u impedansi.
• NVP vrednosti variraju od tipa kabla (legura, poprečni presek...) koji se
koristi i od ovog parametra zavisi samo merenje duţine kabla.
• Bolji TDR ima mogućnost prikaza duţine stranih grana (račvanje/bridge
tap) – DSL primena. Notch filter.
17. INSERTION LOSS SLABLJENJE
COPPER MEASURING
• Slabljenje signala duţ linka.
• Što je duţi link i viša frekvencija signala to je i veće slabljenje. Shodno
tome, treba meriti atenuaciju koristeći najveću frekvenciju za koju je kabl
specificiran da podrţava.
• Slabljenje je potrebno meriti samo se jedne strane linka (sve parice).
• Atenuaciju uzrokuje gubitak energije usled otpora ţice (konvertovanje
energije u toplotu) i izraţena je u decibelima (dB). Niţe vrednosti
atenuacije su indikacija boljih performansi linka.
18. INSERTION LOSS SLABLJENJE
dB
V
dB
V
dB
COPPER MEASURING
V
dB
V
0
1V
-6
.500
-13
.224
-19
.112
-1
.891
-7
.447
-14
.200
-20
.100
-2
.794
-8
.398
-15
.178
-30
.032
-3
.707
-9
.355
-16
.158
-40
.010
-4
.631
-10
.316
-17
.141
-50
.003
-5
.562
-11
.282
-18
.125
-60
.001
-12
.250
-80
.0001
19. RETURN LOSS POVRATNI GUBICI
COPPER MEASURING
• Prilikom karakterisanja kabla predpostavlja se
da veza sa opremom za testiranje (ili krajnjim
korisnikom) i svi konektori izmeĎu imaju
savršeno poklapanje impedanse. Obzirom da
ovo u praksi nije slučaj potrebno je osvrnuti
se na to koliko anomalija (naglih promena u
odnosu na karakterističnu impedansu) u
impedansi moţe imati uticaj na link.
• U aplikacijama sa korišćenjem dve parice
Return Loss maltene nema uticaja, dok za
aplikacije koje koriste sve četiri parice za
prenos u jednom smeru ova pojava izaziva
greške i distorziju signala na primopredajniku
20. NEAR END CROSSTALK (NEXT)
PRESLUŠAVANJE NA BLIŢEM KRAJU
COPPER MEASURING
• Kada se gleda celokupan rad linka sa upredenim paricama,
preslušavanje ima najviše uticaja na performanse linka.
• Preslušavanje je neţeljeni signal koji se sa jedne parice prenosi na
drugu paricu. Preslušavanje se povećava kako se frekvencija povećava.
• Test instrumenti generišu signal u jednoj i mere koliko se signala
prenosi u druge parice. Rezultat je odnos generisanog signala i
izmerene vrednosti u dB.
21. NEAR END CROSSTALK (NEXT)
PRESLUŠAVANJE NA BLIŢEM KRAJU
COPPER MEASURING
• Testiranje se obavlja sa obe
strane za sve kombinacije
parica u odgovarajućim
frekventnim koracima.
• Sto je parica više upredena
manji će efekti preslušavanja
biti
22. FAR END CROSSTALK (FEXT)
PRESLUŠAVANJE NA DALJEM KRAJU
COPPER MEASURING
• Druga „vrsta“ preslušavanja je FEXT i javlja se kada se signal prenosi u
drugu paricu i putuje na njen udaljeni kraj. Ovo preslušavanje podloţno
je slabljenju obzirom da je potrebno da preĎe put cele parice do
udaljnog kraja.
23. TIME DOMAIN REFLECTOMETAR TDR
COPPER MEASURING
• Za dijagnostiku RL grešaka
• Posmatra se vrednost povratnog
signala u %
• Spike: 3%
• Whole: 0.8%
24. TIME DOMAIN CROSSTALK TDX
COPPER MEASURING
• Ukoliko je detektovano preveliko
preslušavanje koristi se metoda
slična TDR metodi za
odreĎivanje gde se problem
tačno manifestuje, s’ tim što se
signal generiše u jednoj parici a
refleksija posmatra u drugoj –
ovaj test se naziva TDX (Time
Domain Crosstalk).
• Spike: 17.5%
• Whole: 5%
25. UZROK GREŠAKA
• High RL / Low Freq – Faulty cable
• High RL / High Freq – Faulty connector / plug
• High RL – Bad connection with outlet, check resistance
• Pull – NEXT – Ties, Less Twisting / RL – Copper microcracks
• Single frequency fail on RL or NEXT – Connectior problem
• Multiple frequency fails on RL or NEXT – Bad cable
• Using gel / High RL – Wait for it to dry
COPPER MEASURING
26. ALIEN CROSSTALK
COPPER MEASURING
STRANO PRESLUŠAVANJE
• Eksterni uticaj – tipično NEXT ili
FEXT koji je meren izmeĎu blizu
poloţenih kablova.
• Kablovi udaljeni 1cm – 2cm će imati
nebitno preslušavanje.
• Alien xTalk se povećava sa:
•
•
•
Korišćenjem vezica ili kanalica
Povećanjem duţine paralelnog
polaganja (2 ili više)
Povećanjem frekvencije prenosa
27. ALIEN CROSSTALK
STRANO PRESLUŠAVANJE
COPPER MEASURING
• Merenja: ANEXT, AFEXT, AACRF, PSANEXT, PSAFEXT, PSAACRF sa
dodatkom nekih prosečnih vrednosti
• Kompletan test za bunt od 48 kablova bi trajao mnogo sati, iz tog
razloga se koriste metode odabira ekstrema za „ţrtvu“ i „ometače“ –
najduţi link iz bunta i okolni linkovi na patch panelu, respektivno.
29. ATTENUATION-TO-CROSSTALK RATIO
COPPER MEASURING
ACR ili ACRN
•
•
•
•
ACR je prikaz koliko
uticaja ima
preslušavanje na
oslabljeni signal koji
prijemnik dobija.
ACR odnos direktno
utiče na bit-error
rate (BER) kao i za
povećanje
retransmisija (usled
grešaka).
ACR > 0
UTP > STP
31. SIGNAL-TO-NOISE RATIO (SNR)
COPPER MEASURING
• Predstavlja odnos (oslabljenog) signala i zbirno svih smetnji koje su
generisane u linku (koje su nastale u samom kablu + od eksternih
izvora).
• Power 50Hz (upredeno) – velik uticaj
SNR = ACR + External Noise
32. POWER SUM NEXT PSNEXT
COPPER MEASURING
• PSNEXT predstavlja zbir preslušavanja u jednoj parici koje se generišu
sa svih drugih parica. Za aplikacije koje za prijem koriste samo jednu
paricu PSNEXT parametar neće biti od značaja dok za tehnologije kao
što je 1000BASE-T ovo merenje moţe dati jasnu sliku signala koji
prijemnik dobija.
33. POWER SUM ATTENUATION TO
CROSSTALK RATIO PSACR
COPPER MEASURING
• PSACRN predstavlja odnos izmeĎu atenuacije (insertion loss) na
udaljenom kraju i kombinovanog preslušavanja svih ostalih parica
(PSNEXT). Veće vrenosti su bolje.
• PSACRF je odnos test signala na bliţem kraju i kombinovanog
preslušavanja svih ostalih parica (PSFEXT) na udaljenom kraju.
35. SHIELD TEST
TEST PLAŠTA
COPPER MEASURING
• Testeri verifikuju postojanje DC
kontinuiteta
• Ukoliko su oba rack-a uzemljena na istu
zemlju testeri neće pronaći grešku
36. UNBALANCED PAIRS TCL i ELTCTL
COPPER MEASURING
• Još jedan uzrok distorzije signala su nebalansirane parice
• Trenutno nije obavezno testirati ove parametre – do sada test na terenu
nije bio moguć (već samo lab)
• Merenje se zasniva na injektovanju diferencijalnog signala (DM) u
upredenu paricu i merenju uprosečene vrednosti signala (CM):
• Na bliţem kraju parice – TCL
• Na daljem kraju parice – ELTCTL
37. UNBALANCED PAIRS TCL i ELTCTL
COPPER MEASURING
• Zbog čega testirati?
• Ethernet prenosi balansirani, diferencijalni signal radi odstranjanja šuma
pri sabiranju na daljem kraju
38. RESISTANCE UNBALANCE
LOOP RESISTANCE
COPPER MEASURING
• Razlika otpora izmeĎu upredenih parica
• Meri se otpor svake ţile i izračunava razlika merenja
• Velik uticaj na napajanje PoE ureĎaja (IP telefoni, kamere; Access
Point...)
41. Modeli linkova: PERMANENT LINK
COPPER MEASURING
• Koristi se za testiranje izvedenih instalacija koje se neće pomerati
• Merenje uključuje konektor na kraju merne vezice
• Maksimum jedan consolidation point (tri konektora po linku)
• „Osnovno testiranje“ – patch cord-ovi u trenutku instalacije nisu dostupni
• Uz naknadno dodavanje odgovarajućih patch cord-ova
postiţe se i Channel link kompatibilnost
43. Modeli linkova: CHANNEL LINK
COPPER MEASURING
• Jedino testirati radi provere end-to-end karakteristika koje uključuju i
korisničke patch cord-ove
• Merenje ne uključuje konektor na kraju korisničkog patch cord-a
• Maksimum do četiri konektora po standardu (ili manje)
46. COPPER MEASURING
VERIFIKACIJA
• Provera osnovnih parametara
kabla – oţičenje i duţina
• Instrument za verifikaciju
garantuje da će kabl da podrţi
Ethernet protokol, ne i aplikaciju
• Ne proverava kabl u odnosu na
standarde ni ispunjenost uslova
za aplikacije
47. COPPER MEASURING
KVALIFIKACIJA
• Testiranje propusne moći kabla
putem ključnih parametara za
prenos glasa, VoIP, 10/100 ili
gigabitni Ethernet
• Testovi za oţičenje, duţinu i
preslušavanje
48. COPPER MEASURING
SERTIFIKACIJA
• PoreĎenje performansi izvedenog strukturnog
kabliranja sa unapred odreĎenim
standardom, koristeći standardom propisane
metode.
• Dokazivanje i demonstracija izvedenog
strukturnog kabliranja potvrĎuje kvalitet
korišćenih komponenti kao i rad instalatera.
50. COMMON PAIR FAULTS
•
•
•
•
•
•
•
•
•
COPPER MEASURING
OPEN – Ţila ili parica u prekidu
PARTIAL OPEN – Visok otpor (korozija na spoju)
SHORT – Spoj izmeĎu ţila
GROUND – Spoj izmeĎu ţile i uzemljenja
BRIDGE TAP – Račvanje ţile u dve ili više putanja
CABLE IMBALANCE – Nebalansirane ţile
CROSS – Greške izmeĎu više parica (neaktivne parice)
CROSS BATTERY – Greške izmeĎu testirane parice i aktivne parice
LOAD COILS – Jako slabljenje DSL (viših) frekvencija
51. PREPORUČENA DMM MERENJA
CO POTS Battery
48 - 52 V Source
Spoljni DC
Tip (A) ↔ Ring (B) ≤ 3 VDC
Tip (A) ↔ Ground ≤ 3 VDC
Ring (B) ↔ Ground ≤ 3 VDC
Spoljni ACV
Tip (A) ↔ Ring (B) ≤ 3 VAC
Tip (A) ↔ Ground ≤ 25 VAC
Ring (B) ↔ Ground ≤ 25 VAC
Otpor izolacije
Tip (A) ↔ Ring (B) > 3.5 M
Tip (A) ↔ Ground > 3.5 M
Ring (B) ↔ Ground > 3.5 M
DC Voltage
AC Voltage
Resistance /
Leakage
Capacitance / Loop Length Estimate
Opens
Cable Balance
DC Current
Loop current for
phone
> 95% for acceptable balance
> 23 mA
COPPER MEASURING
52. DSL KVALIFIKACIJA DSL PARICE
COPPER MEASURING
DC Voltage, AC Voltage, DC Current, Resistance, Capacitance
Indikacija postojanja grešaka na liniji
Power Spectral Density – Šum sa drugih izvora
Insertion Loss, NEXT, FEXT i Signal to Noise Ratio
Impulsni šum i detekcija kalemskih opterećenja (Load Coil)
Poduţni balans
Time Domain Reflectometer
Single and Dual Trace
Koristi se za lociranje grešaka
Lokator grešaka otpora (RFL): 3-wire, 4-wire, Kupfmuller...