2. Manhole Condition Summary:
Number of Manholes: 19
Condition (Y if attention required) Manhole Number Function Cover Steps Shaft Chamber Benching Other Remarks
FMH28
F
-
-
-
-
-
-
Covered over with grass trimmings
SMH30
S
-
-
-
-
-
-
Small sump in MH 600mm
FMH29
F
-
-
-
-
-
Y
MH is Buried
FMH30
F
-
-
-
-
-
Y
MH is Buried
SMH32
S
-
-
-
-
-
Y
In pipe exposed/Cover is above ground
FMH31
F
Y
-
-
-
-
-
Cover frame loose
FMH32
F
Y
-
-
-
-
-
Cover above ground,Frame loose
FMH33
F
Y
-
-
-
-
-
Cover frame loose,Cover above ground
T/PLANT
F
-
-
-
Y
-
Y
Chamber full waste,Unable see bottom
SMH33
S
-
-
-
-
-
-
-
OUTFALL_F
F
-
-
-
-
-
-
Treated Foul Outfall
OUTFALL
S
-
-
-
-
-
-
Storm Outfall
WWTP_MH
F
-
-
-
-
-
Y
Valve joining in and out pipes in MH
SMH31
S
Y
-
-
-
-
-
Cover off set/Catchpit 100- 150mm deep
FMH34A
F
-
-
-
-
-
Y
Out Pipe is Overflow/Full water and Foul
FMH34
F
-
-
-
-
-
Y
Out pipe is sealed around edge
SMH34
S
-
-
-
-
-
-
-
WWTP_SUMP
F
-
-
-
-
-
-
Sump-Two overflow pipes heading out
SMH35
S
-
-
-
-
-
Y
MH is Buried
3. MANHOLE RECORD CARD
NODE REFERENCE
FMH28
COORDINATES (m)
158482.78,84723.35
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
5
Depth to 1st Step
510
Chamber Depth (mm)
2340
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
128.594
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
-
C
300
X
300
-
PVC
-
2.540
126.05
B
-
C
225
X
225
-
PVC
-
2.450
126.14
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH29
C
300
X
300
-
-
PVC
-
2.544
126.05
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Covered over with grass trimmings
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
4. MANHOLE RECORD CARD
NODE REFERENCE
SMH30
COORDINATES (m)
158545.38,84772.46
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
8
Depth to 1st Step
580
Chamber Depth (mm)
2200
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
122.973
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
-
C
450
X
450
-
CO
-
1.800
121.17
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
SMH31
C
600
X
600
-
-
CO
-
2.430
120.54
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Small sump in MH 600mm
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
5. MANHOLE RECORD CARD
NODE REFERENCE
FMH29
COORDINATES (m)
158546.58,84776.20
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
-
HINGED
-
LOCK
-
DUTY
-
-
-
X
-
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
-
Depth to 1st Step
-
Chamber Depth (mm)
-
-
-
X
-
CHAMBER MATERIAL
-
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
-
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH28
C
300
X
300
-
PVC
-
-
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH30
C
300
X
300
-
-
PVC
-
-
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
MH is Buried
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
6. MANHOLE RECORD CARD
NODE REFERENCE
FMH30
COORDINATES (m)
158615.03,84816.84
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
-
HINGED
-
LOCK
-
DUTY
-
-
-
X
-
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
-
Depth to 1st Step
-
Chamber Depth (mm)
-
-
-
X
-
CHAMBER MATERIAL
-
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
-
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH29
C
300
X
300
-
PVC
-
-
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH31
C
300
X
300
-
-
PVC
-
-
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
MH is Buried
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
7. MANHOLE RECORD CARD
NODE REFERENCE
SMH32
COORDINATES (m)
158652.19,84847.71
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
2
Depth to 1st Step
500
Chamber Depth (mm)
1750
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
115.497
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
SMH31
C
600
X
600
-
CO
-
1.850
113.65
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
SMH33
C
600
X
600
-
-
CO
-
1.880
113.62
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
In pipe exposed/Cover is above ground
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
8. MANHOLE RECORD CARD
NODE REFERENCE
FMH31
COORDINATES (m)
158651.29,84844.98
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
4
Depth to 1st Step
500
Chamber Depth (mm)
1800
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
115.757
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH30
C
300
X
300
-
PVC
-
2.120
113.64
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH32
C
300
X
300
-
-
PVC
-
2.150
113.61
Y
X
CONDITION (Y if action required)
COVER
Y
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Cover frame loose
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
9. MANHOLE RECORD CARD
NODE REFERENCE
FMH32
COORDINATES (m)
158700.53,84812.65
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
2
Depth to 1st Step
500
Chamber Depth (mm)
1200
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
114.217
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH31
C
300
X
300
-
PVC
-
1.483
112.73
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH33
C
300
X
300
-
-
PVC
-
1.535
112.68
Y
X
CONDITION (Y if action required)
COVER
Y
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Cover above ground,Frame loose
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
10. MANHOLE RECORD CARD
NODE REFERENCE
FMH33
COORDINATES (m)
158751.62,84778.48
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
2
Depth to 1st Step
530
Chamber Depth (mm)
1190
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
113.396
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH32
C
300
X
300
-
PVC
-
1.240
112.16
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
T/PLANT
C
300
X
300
-
-
PVC
-
1.255
112.14
Y
X
CONDITION (Y if action required)
COVER
Y
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Cover frame loose,Cover above ground
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
11. MANHOLE RECORD CARD
NODE REFERENCE
T/PLANT
COORDINATES (m)
158788.25,84755.47
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
0
Depth to 1st Step
-
Chamber Depth (mm)
3000
-
1500
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
112.233
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH33
C
300
X
300
-
PVC
-
0.800
111.43
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
WWTP
C
300
X
300
-
-
CO
-
0.850
111.38
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
Y
BENCHING
-
OTHER
Y
REMARKS
Chamber full waste,Unable see bottom
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
12. MANHOLE RECORD CARD
NODE REFERENCE
SMH33
COORDINATES (m)
158691.70,84888.65
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
3
Depth to 1st Step
500
Chamber Depth (mm)
2250
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
112.342
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
SMH32
C
600
X
600
-
CO
-
2.370
109.97
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
SMH34
C
600
X
600
-
-
CO
-
2.385
109.96
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
-
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
13. MANHOLE RECORD CARD
NODE REFERENCE
OUTFALL_F
COORDINATES (m)
158833.22,84984.25
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
F
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
-
HINGED
-
LOCK
-
DUTY
-
-
-
X
-
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
-
Depth to 1st Step
-
Chamber Depth (mm)
-
-
-
X
-
CHAMBER MATERIAL
-
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
101.728
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH34
C
225
X
225
-
PVC
-
-
101.73
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
X
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Treated Foul Outfall
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
14. MANHOLE RECORD CARD
NODE REFERENCE
OUTFALL
COORDINATES (m)
158832.59,84985.07
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
F
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
-
HINGED
-
LOCK
-
DUTY
-
-
-
X
-
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
-
Depth to 1st Step
-
Chamber Depth (mm)
-
-
-
X
-
CHAMBER MATERIAL
-
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
101.704
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
SMH35
C
600
X
600
-
CO
-
-
101.70
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
X
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Storm Outfall
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
15. MANHOLE RECORD CARD
NODE REFERENCE
WWTP_MH
COORDINATES (m)
158816.96,84751.13
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
0
Depth to 1st Step
-
Chamber Depth (mm)
950
-
620
X
620
CHAMBER MATERIAL
B
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
108.485
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
TANK
C
225
X
225
-
ST
-
1.000
107.49
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH34A
C
225
X
225
-
-
PVC
-
1.060
107.43
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
Valve joining in and out pipes in MH
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
16. MANHOLE RECORD CARD
NODE REFERENCE
SMH31
COORDINATES (m)
158617.61,84813.73
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
3
Depth to 1st Step
500
Chamber Depth (mm)
1600
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
116.463
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
SMH30
C
600
X
600
-
CO
-
1.603
114.86
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
SMH32
C
600
X
600
-
-
CO
-
1.910
114.55
Y
X
CONDITION (Y if action required)
COVER
Y
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Cover off set/Catchpit 100-150mm deep
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
17. MANHOLE RECORD CARD
NODE REFERENCE
FMH34A
COORDINATES (m)
158753.94,84935.93
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
300
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
0
Depth to 1st Step
-
Chamber Depth (mm)
2290
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
107.784
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
WWTP_MH
C
225
X
225
-
PVC
-
2.300
105.48
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
FMH34
C
225
X
225
-
-
PVC
-
0.800
106.98
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
Out Pipe is Overflow/Full water and Foul
No incoming pipes visible
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
18. MANHOLE RECORD CARD
NODE REFERENCE
FMH34
COORDINATES (m)
158756.07,84941.33
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
4
Depth to 1st Step
500
Chamber Depth (mm)
1512
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
107.606
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
FMH34A
C
225
X
225
-
PVC
-
1.070
106.54
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
OUTFALL_F
C
225
X
225
-
-
PVC
-
1.570
106.04
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
Out pipe is sealed around edge
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
19. MANHOLE RECORD CARD
NODE REFERENCE
SMH34
COORDINATES (m)
158755.40,84943.39
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
H
-
615
X
615
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
850
-
1200
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
0
Depth to 1st Step
-
Chamber Depth (mm)
1500
-
1000
X
1100
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
107.537
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
SMH33
C
600
X
600
-
CO
-
1.510
106.03
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
SMH35
C
600
X
600
-
-
CO
-
1.550
105.99
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
-
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
20. MANHOLE RECORD CARD
NODE REFERENCE
WWTP_SUMP
COORDINATES (m)
158822.12,84760.70
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
F
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
S
HINGED
-
LOCK
-
DUTY
L
-
600
X
600
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
200
-
600
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
3
Depth to 1st Step
840
Chamber Depth (mm)
1250
-
1200
X
-
CHAMBER MATERIAL
P
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
108.297
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
-
C
225
X
225
-
PVC
-
1.300
107.00
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
-
C
225
X
225
-
-
PVC
-
1.305
106.99
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
-
REMARKS
Sump-Two overflow pipes heading out
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE
INTERNAL IMAGE
21. MANHOLE RECORD CARD
NODE REFERENCE
SMH35
COORDINATES (m)
158759.76,84945.63
LOCATION
Grenagh
SUS CODE
-
SURVEY DATE
13 Dec 2013
YEAR LAID
-
STATUS
PR
FUNCTION
S
NODE TYPE
M
COND
DIMENSIONS(mm)
TOXIC ATMO
-
COVER
SHAPE
-
HINGED
-
LOCK
-
DUTY
-
-
-
X
-
GAS TYPE
-
SHAFT
SIDE ENTRY
-
REGULACOURSES
-
DEPTH (mm)
-
-
-
X
-
EVIDENCE OF VERMIN
-
CHAMBER
SOFFIT
-
No.STEPS
-
Depth to 1st Step
-
Chamber Depth (mm)
-
-
-
X
-
CHAMBER MATERIAL
-
STRUCTURAL CONDITION
-
MAINTENANCE CONDITION
-
DEPTH OF FLOW (mm)
-
DEPTH OF SILT (mm)
-
HEIGHT SURCH (mm)
-
COVER LEVEL
(m AD)
-
UPSTREAM REFERENCE
PIPE SHAPE
PIPE SIZE (mm)
BACKDROP DIAM (mm)
PIPE MATERIAL
LINING
DEPTH FROM COVER (m)
INVERT LEVEL (m AD)
INCOMING PIPES
A
SMH34
C
600
X
600
-
CO
-
-
B
X
C
X
D
X
E
X
F
X
OUTGOING PIPES
DOWNSTREAM REFERENCE
COND
CRITY
X
OUTFALL
C
600
X
600
-
-
CO
-
-
Y
X
CONDITION (Y if action required)
COVER
-
STEPS
-
SHAFT
-
CHAMBER
-
BENCHING
-
OTHER
Y
REMARKS
MH is Buried
-
LOCATION SKETCH
PLAN SKETCH
LOCATION IMAGE